Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open is a versatile combination of test system hardware, I/O and software tools. It accelerates the creation of streamlined test systems that are easy to enhance and maintain by giving you greater choice in measurements, connectivity and programming. Utilizing these advantages, your team has more time to focus on what matters most-- the performance, reliability and delivery of your product. www.agilent.com Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support y ou need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at: Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extracost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Detailed specifications, application briefs and more for: DC Power Supplies DC Electronic Loads AC Power Solutions Digital Multimeters/Voltmeters www.agilent.com/find/contactus Function/Arbitrary Phone or Fax United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Waveform Generators Data Acquisition and Switching System and Bench Instruments Catalog www.agilent.com/find/open Agilent Technologies' Test and Measurement Support, Services, and Assistance Frequency Counters LXI System and Bench Instruments Catalog July 2006 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com Contacts revised: 09/26/05 Product specifications and descriptions in this document subject to change without notice. Bluetooth and the Bluetooth logos are trademarks owned by BluetoothSIG, Inc., USA, and licensed to Agilent Technologies, Inc. Microsoft(R) and Windows(R) are U.S. registered trademarks of Microsoft(R) Corporation LabVIEW TM is a U.S. registered trademark of National Instruments Corporation (c) Agilent Technologies, Inc. 2006 Printed in USA, July 30, 2006 5989-4702EN July 2006 SPDCvr_LoRz.indd 1 7/25/06 5:03:35 PM Solutions to match your new test and measurement challenges. From Power Supplies and Digital Multimeters to Data Acquisition and Switching Systems One quick browse through this catalog will convince you that Agilent products offer so much more than simple power generation, or measurement, or signal switching. In each product category, we've integrated the capabilities you need for a complete solution. Our one-box approach improves test results while cutting costs, complexity and rack size. This catalog contains detailed technical and application information on digital multimeters, DC power supplies, arbitrary waveform generators, and many more instruments. With over 180 products to choose from, it includes easy to use selection guides for each product category to help you select the best product for your application. Also highlighted are our most recent product introductions like the N6700 Low-Profile Modular Power System, the 34410A, 34411A and 34405A Digital Multimeters, and the new L4400 Series LXI Switching and Control Instruments. For the most comprehensive product information, we've provided a unique URL to each product's website where you can find data sheets and application notes, download drivers, and view videos and interactive demos. Products you can count on year after year We've been a leader in the power and measurement business for more than four decades because engineers like you know they can count on Agilent performance and reliability. We specify and guarantee performance for the entire integrated system, so you know what you're really dealing with-unlike the typical "rack-and-stack" setup. Plus, every Agilent product in this catalog has a global warranty. We know you have more important things to do than shop around for serveral different system and bench instruments. That's why we've made such a wide range of products available through Agilent. The experienced engineers at Agilent can help you select just the right solutions for your application and your budget, then arrange fast shipping so you can get to work in a hurry. New Products 34410A and 34411A Digital Multimeters The 34410/11A 6 1/2 digit dual display DMMs are our latest generation of digital multimeters. Both models offer enhanced functionality for bench and system users. They provide precise triggering, extraordinary speed (up to 50,000 readings per second at 41/2 digits on the 34411A), expanded memory, and datalogging wizard. With open connectivity, GPIB, USB and LAN are standard plus they are LXI class C compliant. See Page 178 34405A Digital Multimeter The 34405A is an expansion of the 34401A, 34410A and 34411A product family, which offers value, performance, reliability and ease-of-use, and is part of the Agilent Open suite of products and services. The 34405A is an affordable digital multimeter specially designed to help manufacturers and educational institutions control costs on test and measurement equipment. The key benefits and features include easy-to-read AC and DC measurements with dual display capabilities, 0.025 percent DC accuracy and 120,000 counts resolution. See Page 171 N6700 Low-Profile Modular Power System The small, flexible and fast N6700 MPS has been enhanced to provide 3x the power in the same space, creating the highest power and the highest number of outputs you can put in 1U of rack space. Two new mainframes (N6701A 600 W, N6702A 1200 W) provide 4 outputs in 1U. Four new basic DC modules (N6773A-76A) have been added at 300 W per 1 slot-wide module. All hardware is interchangeable; use new and existing modules in existing N6700B mainframes or any of the 20 modules in the 2 new mainframes. With open connectivity, GPIB, USB and LAN are standard, plus they are LXI class C compliant. See Page 69 L4400 Series Switching and Control LXI Instruments The seven new LXI instruments are self-contained, 1U, 1/2 rack LXI instruments with a broad offering of functionality in switching, digital I/O, D/A converters and counters. The standard LAN connectivity and fully-featured graphical web interface enable easy connection to the PC and remote access from anywhere in the world. With choices, you can select the low cost solution that best fits your needs. See Page 138 III Go beyond VXI, PXI and GPIB with LXI LXI Products open new possibilities in testing N5700 Series LXI (LAN eXtensions for Instrumentation) is a versatile architecture that enables you to create test systems with less effort. The LXI standard is based on proven, widely used standards with a long and stable history. This new open architecture enables you to turn on a system faster and gain faster throughput, all in a smaller space and in less time. The LXI Consortium is a not-for-profit corporation originally established by Agilent Technologies and VXI technologies. It has more than 40 members from test and measurement companies, industry professionals, system integrators and government representatives. See Agilent's extensive library of application notes, the Test System Developers Guide, code samples and other resources at www.agilent.com/find/lxi. To learn more about the LXI standard, go to wwwlxistandard.org N6700 System N5700 Series System DC Power Supplies * * * * * Fully compliant to LXI class C specification Choose from 24 models up to 1500 W, up to 600 V, up to 180 A Operate on LAN, GPIB and USB interfaces Supports parallel and series connections of multiple supplies Simplify cabling with built-in measurements See Page 26 N6700 Low-Profile Modular Power System L4400 Series * * * * * * Fully compliant to LXI class C specification Create a system of up to 4 outputs of up to 300 W/output in 1U of rack space Change output voltage as fast as 200 microseconds Synchronize to other events with hardware and software triggering Capture transients with built-in digitizer (up to 50 kHz, 4096 points) Generate automated sequencing of up to 512 output settings See Page 69 L4400 Series LXI Switching and Control Instruments * * * * * * Fully compliant to LXI class C specification Compact, self-contained 1U, 1/2 rack size Choose from 7 instruments in switching, digital I/O, D/A converters Full-featured Graphical Web interface Standard Dsub connectors for flexible connection options Software drivers for most common programming environments See Page 138 Visit www.agilent.com/find/open for more information and to see the latest tools and technologies IV Agilent 34980A Agilent 34980A Multifunction Switch/Measure Unit * Fully compliant to LXI class C specification * 8-slot Mainframe with optional integrated 6 1/2 digit DMM * 19 plug-in modules to choose from - DC to 20 GHz switching, Digital I/O, D/A Converter, Counter/Totalizer * Up to 560 Multiplexer channels or 1024 Matrix cross points in a single Mainframe * Full-featured Graphical Web interface * Standard drivers for most common programming environments See Page 159 33220A Function/Arbitrary Waveform Generator, 20 MHz Agilent 33220A * * * * * * * Fully compliant to LXI class C specification 20 MHz sine and square waveforms Ramp, triangle, noise, and DC waveforms Pulse generation with variable edge 14-bit, 50 MSa/s, 64 Kpoint arbitrary waveforms AM, FM, PM, FSK, and PWM modulation types Linear & logarithmic sweeps and burst operation modes See Page 201 34410A Digital Multimeter, 6-1/2 digit high performance Agilent 34410A & 34411A * * * * Fully compliant to LXI class C specification 10,000 readings/s @ 5 1/2 digits continuous to the PC Capacitance & temperature measurements Peak measurements and dual display Data logger with improved usability 50,000 reading non-volatile memory See Page 178 34411A Digital Multimeter, 6-1/2 digit enhanced performance * Fully compliant to LXI class C specification * Same capability as 34410A Plus 50,000 readings/s @ 4 1/2 digits continuous to the PC 1 M reading volatile memory See Page 178 Visit www.agilent.com/find/open for more information and to see the latest tools and technologies V Table of Contents New Products, Agilent Open, LXI iii-v DC Power Supply Selection Index 3-9 DC Power Supply Feature Description Index 10-13 Basic DC Power Supplies...essential features for a tight budget 14 Single-Output: 30-60 W Multiple-Output: 35 and 50 W Triple-Output: 80 W GPIB Single-Output: 120-200 W GPIB Single & Dual Output: 30-100 W GPIB Autoranging: 200-1000 W GPIB Single Output: 750 W & 1500 W GPIB, LAN, USB 15-16 17 18 19-20 21-22 23-25 26-30 High Performance DC Power Supplies...speed and accuracy for test optimization 31 Single-Output: 40-500 W GPIB Single-Output: 200-500 W Single-Output: 2000 W GPIB Single-Output: 2000 W Single-Output: 5000 W GPIB Single-Output: 6600 W GPIB Multiple-Output: 40-105 W GPIB Precision Multiple-Output: 25-50 W GPIB Low-Profile Modular Power System: 50-300 W GPIB, LAN, USB Modular Power System: 1200 W per Mainframe GPIB 32-38, 42-45 39-41, 46-49 50-56 57-60 61-62 63-64 65-66 67-68 69-75 76-79 Application Specific DC Power Supplies...tailored solutions for specific needs 80 Mobile Communications DC Sources Solar Array Simulators 81-87 88-90 DC Electronic Loads...maximize throughput with real life loading conditions 91 Multiple-Input Electronic Loads Single-Input Electronic Loads 92-98 99-102 AC Power Source/Analyzers....an integrated AC power solution 103 AC Power Source/Analyzers: 375-1750 VA Power Products AC Line Voltage and Cord Options Power Products Applications Information Top 10 FAQs AC Power and Load Connections Power Product Terms 104-111 112-117 118 118-122 123-130 131-136 More detailed specifications at www.agilent.com/find/power 1 Table of Contents (Continued) Data Acquisition and Switching 137 L4400 Series LXI Switching and Control Instruments 34970A Low-Cost Data Acqusition/Switch Unit 34980A Multifunction Switch/Measure Mainframe and Modules 138-150 151-158 159-169 Digital Multimeters, Voltmeters 170 34405A Digital Multimeter, 5 1/2 -digits 171-174 34401A Digital Multimeter, 6 1/2 -digits 34410A and 34411A Series High Performance Digital Multimeter, 6 1/2 -digits 34420A Nanovolt/Micro-ohm Meter 3458A Digit Multimeter, 8 1/2 -digits 175-177 178-183 184-186 187-189 Frequency Counters 190 53131A Frequency Counter, Two Ch, 10, -digit/s 53132A Frequency Counter, Two Ch, 12, -digit/s 53181A Frequency Counter, Single Ch, 10, -digit/s 53140 Series Microwave Frequency Counter with Power Meter 53150 Series Microwave CW Frequency Counter 191-193 191-193 191-193 194-196 197-199 Function/Arbitrary Waveform Generators 200 33220A Function/Arbitrary Waveform Generator, 20 MHz 33250A Function/Arbitrary Waveform Generator, 80 MHz 201-203 204-206 VXI Instruments, 3499 Switch Solutions and Connectivity Products Model Number Index Replacement Guide 207 208-209 210 More detailed specifications at www.agilent.com/find/power 2 DC Power Supply Selection Index Maximum Volts Maximum Amps Maximum Watts Number of Outputs GPIB Model Number Type Page Number 3 300 900 1 * 6671A-J08 Performance 51 3.3 1000 3300 1 * 6680A-J04 Performance 61 5 10 50 up to 4 * N6731B Basic 72 5 20 100 up to 4 * N6741B Basic 73 5 875 4400 1 * 6680A Performance 61 5.7 20 100 up to 8 * 66101A-J03 Performance 77 6 2.5 15 3 E3630A Basic 17 6 5 30 3 E3631A Basic 18 6 60 360 1 6551A-J03 Performance 47 6 60 360 1 6 100 600 1 * 6651A-J03 Performance 43 * N5741A Basic 26 29 6 180 1080 1 * N5761A Basic 6.7 30 200 1 * 6033A Autoranging 23 7 0.015 0.11 2 * 6625A Performance 67 7 0.015 0.11 4 * 6626A Performance 67 7 5 35 3 * 6623A Performance 65 7 5 35 4 * 6624A Performance 65 7 10 70 2 * 6621A Performance 65 7 10 70 3 * 6623A Performance 65 7 120 1000 1 * 6031A Autoranging 23 8 3 24 1 * E3640A Basic 21 8 3 24 2 * E3646A Basic 22 8 3 30 1 E3610A Basic 15 8 5 40 1 * 6611C Performance 32 8 5 40 1 * E3642A Basic 21 8 5 40 2 * E3648A Basic 22 8 6 48 1 E3614A Basic 15 8 6.25 50 up to 4 * N6732B Basic 72 8 8 80 1 * E3644A Basic 21 8 10 80 1 * 6631B Performance 39 8 12.5 100 up to 4 * N6742B Basic 74 8 16 128 up to 8 * 66101A Performance 76 More detailed specifications at www.agilent.com/find/power 3 DC Power Supply Selection Index Maximum Volts Maximum Amps Maximum Watts Number of Outputs GPIB 8 20 160 1 8 20 160 1 * 8 20 160 1 * 8 50 400 1 8 50 400 1 8 90 720 1 8 165 1320 1 8 220 1760 1 8 220 1760 1 * 8 580 4600 1 10 5 50 1 10 50 500 1 10 50 500 1 10 200 2000 1 10 200 2000 1 12 1.5 18 12 1.5 12 (Continued) Model Number Type 6541A Performance 39 6641A Performance 36 E3633A Basic 19 6551A Performance 46 * 6651A Performance 42 * N5742A Basic 26 * N5762A Basic 29 6571A Performance 57 6671A Performance 50 * 6681A Performance 61 * 6611C-J05 Performance 32 6551A-J01 Performance 47 6651A-J01 Performance 42 6571A-J04 Performance 58 * 6671A-J04 Performance 51 2 * 66309B Mobile Communications 81 18 2 * 66309D Mobile Communications 81 1.5 18 2 * 66319B Mobile Communications 81 12 1.5 18 2 * 66319D Mobile Communications 81 12 12 150 up to 8 * 66101A-J05 Performance 77 12.5 60 750 1 * N5743A Basic 26 12.5 120 1500 1 * N5763A Basic 29 13 15.3 200 1 6541A-J04 Performance 40 13 15.3 200 1 6641A-J04 Performance 37 14 150 2000 1 6571A-J03 Performance 57 14 150 2000 1 6671A-J03 Performance 51 15 2 30 1 E3610A Basic 15 15 3 45 2 * 66309B Mobile Communications 81 15 3 45 2 * 66309D Mobile Communications 81 15 3 45 1 * 66311B Mobile Communications 81 15 3 45 2 * 66319B Mobile Communications 81 15 3 45 2 * 66319D Mobile Communications 81 15 3 45 2 * 66321B Mobile Communications 81 15 3 45 2 * 66321D Mobile Communications 81 * * * Page Number More detailed specifications at www.agilent.com/find/power 4 DC Power Supply Selection Index (Continued) Maximum Volts Maximum Amps Maximum Watts Number of Outputs GPIB Model Number Type Page Number 15 7 105 1 * E3632A Basic 19 15 10 150 up to 8 * 66102A-J05 Performance 77 15 120 1800 1 6571A-J17 Performance 58 15 120 1800 1 * 6671A-J17 Performance 51 15 440 6600 1 * 6690A Performance 63 16 0.2 3.2 2 * 6625A Performance 67 16 0.2 3.2 4 * 6626A Performance 67 16 0.2 3.2 2 * 6628A Performance 67 16 0.2 3.2 4 * 6629A Performance 67 17 30 510 1 * 6651A-J09 Performance 43 20 0.5 10 3 E3630A Basic 17 20 1.5 30 1 E3611A Basic 15 20 1.5 30 1 * E3640A Basic 21 20 1.5 30 2 * E3646A Basic 22 20 2 40 1 * 6612C Performance 32 20 2 40 3 * 6623A Performance 65 20 2 40 4 * 6624A Performance 65 20 2 40 4 * 6627A Performance 65 20 2.5 50 1 * E3642A Basic 21 20 2.5 50 2 * E3648A Basic 22 20 2.5 50 up to 4 * N6733B Basic 72 20 3 60 1 E3615A Basic 16 20 4 80 2 * 6621A Performance 65 20 4 80 2 * 6622A Performance 65 20 4 80 3 * 6623A Performance 65 20 4 80 1 * E3644A Basic 21 20 5 100 1 * 6632B Performance 34 20 5 100 1 * 66332A Mobile Communications 81 20 5 100 up to 4 * N6743B Basic 74 20 7.5 150 up to 8 * 66102A Performance 76 20 10 200 1 * 6033A Autoranging 23 20 10 200 1 * 6038A Autoranging 23 20 10 200 1 6542A Performance 39 20 10 200 1 * 6642A Performance 36 20 10 200 1 * E3633A Basic 19 20 15 300 up to 4 * N6773A Basic 71 20 15 300 1 * 6651A-J09 Performance 43 20 25 500 1 6552A Performance 46 20 25 500 1 * 6652A Performance 42 20 38 760 1 * N5744A Basic 26 20 50 1000 1 * 6031A Autoranging 23 20 50 1000 1 * 6032A Autoranging 23 More detailed specifications at www.agilent.com/find/power 5 DC Power Supply Selection Index Maximum Volts Maximum Amps Maximum Watts (Continued) Number of Outputs GPIB Model Number Type Page Number * N5764A Basic 29 6572A Performance 57 20 76 1520 1 20 100 2000 1 20 100 2000 1 * 6672A Performance 50 21 240 5000 1 * 6682A Performance 61 24 6 100 up to 8 * 66103A-J12 Performance 78 24 85 2000 1 * 6672A-J04 Performance 51 25 1 25 2 E3620A Basic 17 25 1 25 3 * E3631A Basic 18 25 7 160 1 * E3634A Basic 19 25 7 175 1 * E3634A Basic 19 27 20 540 1 * 6652A-J03 Performance 43 28 5 140 up to 8 * 66103A-J09 Performance 78 30 3.3 100 1 * 66332A-J01 Mobile Communications 81 30 4 120 1 * E3632A Basic 19 30 17.5 500 1 * 6653A-J17 Performance 43 30 17.5 525 1 6553A-J17 Performance 47 30 25 750 1 * N5745A Basic 26 30 50 1500 1 * N5765A Basic 29 30 220 6600 1 * 6691A Performance 63 32 160 5100 1 * 6683A Performance 61 35 0.8 28 2 * E3647A Basic 22 35 0.8 30 1 * E3641A Basic 21 35 0.85 30 1 E3611A Basic 15 35 1.25 40 up to 8 * 66105A-J01 Performance 78 35 1.4 49 2 * E3649A Basic 22 35 1.4 50 1 * E3643A Basic 21 35 1.5 50 up to 4 * N6734B Basic 72 35 1.7 60 1 E3616A Basic 16 35 2.2 80 1 * E3645A Basic 22 35 3 80 3 * 6623A-J03 Performance 65 35 3 100 up to 4 * N6744B Basic 74 35 4.5 150 up to 8 * 66103A Performance 76 35 6 210 1 6543A Performance 39 35 6 210 1 * 6643A Performance 36 35 8.5 300 up to 4 * N6774A Basic 71 35 15 525 1 6553A Performance 46 35 15 525 1 6653A Performance 42 35 60 2100 1 6573A Performance 57 35 60 2100 1 * 6673A Performance 50 37 4 150 up to 8 * 66103A-J01 Performance 77 37.5 45 1690 1 6573A-J03 Performance 58 37.5 45 1690 1 6673A-J03 Performance 51 * * More detailed specifications at www.agilent.com/find/power 6 DC Power Supply Selection Index (Continued) Maximum Volts Maximum Amps Maximum Watts Number of Outputs GPIB Model Number Type 40 3.6 100 up to 8 * 66103A-J02 Performance 77 40 5 200 1 * 6643A-J11 Performance 37 40 12.5 500 1 6553A-J04 Performance 47 40 12.5 500 1 * 6653A-J04 Performance 43 40 19 760 1 * N5746A Basic 26 40 38 1520 1 * N5766A Basic 29 40 50 2000 1 6573A-J08 Performance 58 40 50 2000 1 * 6673A-J08 Performance 52 40 128 5100 1 * 6684A Performance 61 43.5 11 480 1 * E4350B-J04 Solor Array Simulator 89 50 0.5 25 2 * 6625A Performance 67 50 0.5 25 4 * 6626A Performance 67 50 0.8 40 3 * 6623A Performance 65 50 0.8 40 4 * 6624A Performance 65 50 0.8 40 4 * 6627A Performance 65 50 1 50 1 * 6613C Performance 32 50 1 50 2 * 6625A Performance 67 50 1 50 4 * 6626A Performance 67 50 1 50 2 * 6628A Performance 67 50 1 50 4 * 6629A Performance 67 50 1.5 50 up to 4 * N6761A Performance 69 50 2 80 2 * 6622A Performance 65 50 2 100 1 * 6633B Performance 34 50 3 100 up to 4 * N6762A Performance 69 50 4 200 1 * E3634A Basic 19 50 5 50 up to 4 * N6751A Performance 69 50 10 500 1 * 6554A-J05 Performance 48 50 10 500 1 6654A-J05 Performance 44 50 10 100 up to 4 * N6752A Performance 69 50 42 2000 1 * 6574A-J07 Performance 58 50 42 2000 1 * 6674A-J07 Performance 52 51.8 10 518 1 * E4350B-J03 Solar Array Simulator 89 54 9.6 480 1 * E4350B-J01 Solar Array Simulator 88 55 3 165 1 * 66104A-J09 Performance 78 56 38 2000 1 6574A-J03 Performance 58 56 38 2000 1 6674A-J03 Performance 52 60 0.5 30 1 E3612A Basic 15 60 0.5 30 1 * E3641A Basic 21 60 0.5 30 2 * E3647A Basic 22 * Page Number More detailed specifications at www.agilent.com/find/power 7 DC Power Supply Selection Index (Continued) Maximum Volts Maximum Amps Maximum Watts Number of Outputs GPIB Model Number Type Page Number 60 0.8 48 2 * E3649A Basic 22 60 0.8 50 1 * E3643A Basic 21 60 0.8 50 up to 4 * N6735B Basic 72 60 1 60 1 E3617A Basic 16 60 1.3 80 1 * E3645A Basic 22 60 1.6 100 up to 4 * N6745B Basic 74 60 2.5 150 up to 8 * 66104A Performance 76 60 3.3 200 1 * 6038A Autoranging 23 60 3.5 210 1 6544A Performance 39 60 3.5 210 1 * 6644A Performance 36 60 5 300 up to 4 * N6775A Basic 71 60 9 540 1 6554A Performance 46 60 9 540 1 * 6654A Performance 42 60 12.5 750 1 * N5747A Basic 28 60 17 1200 1 * 6030A Autoranging 23 60 17.5 1200 1 * 6032A Autoranging 23 60 25 1500 1 * N5767A Basic 30 60 35 2100 1 6574A Performance 57 60 35 2100 1 * 6674A Performance 50 60 110 6600 1 * 6692A Performance 63 65 8 480 1 * E4350B Solar Array Simulator 88 68 7 480 1 * E4350B-J06 Solar Array Simulator 89 70 3 200 1 * 6644A-J09 Performance 37 70 3 200 1 * 6544A-J09 Performance 40 70 7.5 500 1 6554A-J04 Performance 48 70 7.5 500 1 6654A-J04 Performance 44 80 6 480 1 6554A-J12 Performance 48 80 6 500 1 * 6654A-J12 Performance 44 80 9.5 760 1 * N5748A Basic 28 80 19 1520 1 * N5768A Basic 30 86 6 516 1 * E4350B-J02 Solar Array Simulator 88 32 * 100 0.5 50 1 * 6614C Performance 100 0.5 50 up to 4 * N6736B Basic 72 100 1 100 1 * 6634B Performance 34 100 1 100 up to 4 * N6746B Basic 74 100 3 300 up to 4 * N6776A Basic 71 100 7.5 750 1 * N5749A Basic 28 100 15 1500 1 * N5769A Basic 30 100 22 2000 1 6575A-J08 Performance 59 70/80 30/26 2000 1 E4356A Performance 55 * More detailed specifications at www.agilent.com/find/power 8 DC Power Supply Selection Index (Continued) Maximum Volts Maximum Amps Maximum Watts Number of Outputs GPIB Model Number Type 100 22 2000 1 * 6675A-J08 Performance 53 110 20 2000 1 6575A-J09 Performance 59 110 20 2000 1 6675A-J09 Performance 53 120 0.25 30 1 E3612A Basic 15 120 1.25 150 up to 8 66105A Performance 76 120 1.5 180 1 6545A Performance 39 120 1.5 180 1 6645A Performance 36 120 4.5 540 1 6555A Performance 46 120 4 540 1 6655A Performance 42 120 18 2160 1 6575A Performance 57 120 18 2160 1 * 6675A Performance 50 130 4 480 1 * E4351B Solar Array Simulator 88 135 16 2000 1 6575A-J06 Performance 59 135 16 2000 1 6675A-J06 Performance 52 150 1.2 150 1 6545A-J05 Performance 40 150 1.2 150 1 * 6645A-J05 Performance 37 150 3.2 500 1 * 6655A-J05 Performance 44 150 5 750 1 * N5750A Basic 28 150 10 1500 1 * N5770A Basic 30 150 15 2000 1 * 6675A-J11 Performance 53 150 15 2250 1 6575A-J11 Performance 59 156 3 500 1 6555A-J10 Performance 48 156 3 500 1 6655A-J10 Performance 44 160 13 2000 1 6575A-J04 Performance 59 160 13 2000 1 * 6675A-J04 Performance 52 170 1 170 1 * 6645A-J06 Performance 37 200 0.75 150 up to 8 * 66106A Performance 76 200 5 1000 1 * 6035A Autoranging 23 200 5 1200 1 * 6030A Autoranging 23 200 11 2000 1 6575A-J07 Performance 59 * * * * * * Page Number 200 11 2000 1 * 6675A-J07 Performance 53 300 2.5 750 1 * N5751A Basic 28 300 5 1500 1 * N5771A Basic 30 500 2 1000 1 * 6035A Autoranging 23 600 1.3 780 1 * N5752A Basic 28 600 2.6 1560 1 * N5772A Basic 30 More detailed specifications at www.agilent.com/find/power 9 200 W - 2000 W - 1200 W 500 W 6600 W Max Voltage 500 V 100 V 50 V 50 V 120 V 120 V Max Current 120 A 10 A 10 A 2A 50 A 875 A Page 23 32, 34 65 67 36, 42 50, 61, 63 76 Ou leul ut M N5 N6 70 70 0S 0S er er ie ie s sS er in ies gl e- Si ng Ou le tp & m m 0S 64 E3 0& 63 E3 tip at ic un em ile ob M s ie er 0S 30 66 Co Sy er w Po ar ul od M 0 00 66 200 W - 40 W 1000 W 100 W st ut -O le ng Si s 69 -6 70 66 Max Power s pu t pu -O le ie er 0S 50 66 & 40 66 ut le ng Si s rie Se ec Pr s rie Se 20 66 ul M n io is tip ul M s rie Se 20 66 tip t pu ut -O le Si s rie Se 30 66 & 25 W & 50 W t ut -O t pu ut -O le ng s er ng ra to Au s rie Se 10 40 W & 80 W 66 30 60 DC Range io pu ns t tp ut DC Power Supply Feature Description Index 40 W100 W 30 W 200 W 700 W 1500 W 50 W 300 W 200 V 20 V 60 V 600 V 100 V 16 A 5A 20 A 180 A 20 A 81 19, 21 26 69 Configuration Features * "One-box" solution To preserve rack space and interconnections, the voltage and current programmers, current shunt, and DVM are built-in to one package. * * * * * * * * * Modular power system (multiple reconfigurable outputs) Modules can be installed into a mainframe, and configuration can be changed at any time. * * * Serial link Up to 16 power supply outputs can share one GPIB address when connected with a telephone style cable. * * * * Analog programming and monitoring ports Analog programming ports allow the power supply to be used as a power amplifier, responding to an external voltage signal. Monitoring ports allow an external DMM to monitor the power-supply outputs. * * S AP S S P P up to 2 up to 2 identical identical outputs outputs S AP S AP * * Up to 4 66309 B/D 66319 B/D * * * * * Auto-parallel, auto-series, parallel, and series operation When connected in auto-parallel or autoseries, only one unit has to be programmed to take advantage of the full power from all. AP=auto-parallel AS=auto-series S=series P=parallel * * Up to 8 Multiple non-reconfigurable outputs Up to four outputs are included in one package, and they share one GPIB address. Relay connect, disconnect, & polarity reversal Optionally integrated with the power supply * S, P 66332A Only S, P * Disconnect only * * * For more detailed specifications see the product manual at www.agilent.com/find/power 10 ut tp Ou io tp & Ou le ng gl e- Si in ies er ie ie s sS er 0S er 70 0S N6 70 N5 700 W 1500 W ut M un m m 0S 64 E3 0& 63 E3 66 Co ile ob M s ie er 0S 30 30 W 200 W ul s em st Sy er w Po ar ul od M 0 00 ic t pu ut -O le ng Si s ie er 66 40 W100 W tip at t pu ut -O le ng Si 0S 69 -6 70 66 40 66 200 W - 2000 W - 1200 W 500 W 6600 W le- ns t pu ut le ul s rie 50 66 & Se 66 Se ec Pr s rie s rie 20 Se 20 66 25 W & 50 W tip t n io is tip ul M Se 30 66 & M ut -O le Si s rie to Au s rie Se 10 40 W & 80 W 66 30 60 pu -O le ng s er ng ra (Continued) DC Range -O t pu ut DC Power Supply Feature Description Index Max Power 200 W - 40 W 1000 W 100 W 50 W 300 W Max Voltage 500 V 100 V 50 V 50 V 120 V 120 V 200 V 20 V 60 V 600 V 100 V Max Current 120 A 10 A 10 A 2A 50 A 875 A 16 A 5A 20 A 180 A 20 A Page 23 32, 34 65 67 36, 42 50, 61, 63 76 81 19, 21 26 69 Output Voltage and Current Range Changing Single Range The output voltage v is limited by a single maximum value. The output current is limited by a single maximum value. Single Range + Peak Current Pulse A limited amplitude and limited width v current pulse can be sourced beyond the maximum static current limit. Autoranging A wide, continuous range of voltage and v current combinations are available automatically at the maximum power level. Multiple-output range changing Automatic range changing gives maximum power to v two different voltage and current combinations. * * * * * l * N6730 N6740 N6770 * l * * N6750 N6760 l * * * l * Precision multiple-output range changing Voltage and current ranges can be chosen independently to v provide greater l resolution. * N6760 Performance Characteristics Output ripple and noise (Peak-to-peak, 20 Hz to 20 MHz) 30 - 160 mV Output programming response time Rise and fall time with full resistive load (10 to 90% and 90 to 10%) Does not include command processing time. *200 W: Programming resolution (percent of full scale) 3 mV (10 mV to 25 mV in fast mode) 3 mV 3 mV 3 mV7 mV 7 mV25 mV 5-50 mV 3-10 mV 2-8 mV 60300 mV 6 mV N6750 N6760 10-30 mV N6730 N6740 2 ms (100 ms - (0.4 ms 200 ms) in fast 1000 W: mode) (300 ms 2000 ms) 2-6 ms 6 ms 15 ms 9 ms195 ms 20 ms50 ms 0.4 ms2 ms 60 ms 0.08 s to 0.30 s * * 0.025% 0.03% 0.007% 0.025% 0.025% 0.03% 0.025% 0.025%/ 0.007% * * 0.025% *See Datasheet or User's Guide for complete details For more detailed specifications see the product manual at www.agilent.com/find/power 11 ut tp Ou io Ou egl in ie s sS er ie 0S er 70 0S N6 70 N5 700 W 1500 W tp & le ng Si ies er 0S 64 E3 0& 63 E3 30 W 200 W ut M un m m Co ile ob M s ie er 0S 30 66 ul s em st Sy er w Po ar ul od M ic t pu ut -O le ng Si s ie 0 00 66 200 W - 2000 W - 1200 W 40 W500 W 6600 W 100 W tip at t pu ut -O le er 0S 69 -6 70 66 40 66 le- ns t pu ut le tip Si s rie Se 50 66 & Se 66 ng M n io is ec Pr s rie s rie 20 Se 20 66 40 W & 25 W & 80 W 50 W ul pu ut tip ul M Se 30 66 & 10 -O le Si s rie to Au s rie Se 66 30 60 t ut -O le ng s er ng ra (Continued) DC Range -O t pu DC Power Supply Feature Description Index Max Power 200 W - 40 W 1000 W 100 W 50 W 300 W Max Voltage 500 V 100 V 50 V 50 V 120 V 120 V 200 V 20 V 60 V 600 V 100 V Max Current 120 A 10 A 10 A 2A 50 A 875 A 16 A 5A 20 A 180 A 20 A Page 23 32, 34 65 67 36, 42 50, 61, 63 76 81 19, 21 26 69 GPIB Programming Features GPIB programming of voltage and current Self-documenting programming commands mean that programming is done in units of volts and amps, not in percentages or binary representations. * * * * * * * * * Measured voltage and current read-back over the GPIB The output is read back in units of volts and amps. * * * * * * * * 0 4 0 4 5 6670-5 6680-4 6690-4 5 16/5 0 10 7 0 0 * * * GPIB programmable overvoltage protection Can be enabled to quickly down-program the output and set SRQ and/or DFI/RI. T = Can generate trigger. M = Overvoltage, the level is set manually with a front-panel control. M * T T GPIB programmable overcurrent protection Can be enabled to quickly down-program the output and set SRQ and/or DFI/RI. T = Can generate trigger. * * * Overtemperature protection Will down-program the output and can be enabled to set SRQ and/or DFI. T = Can generate trigger. * * * Store-recall states Complete operating states can be stored in nonvolatile memory. Each state specifies not only the output voltage and current, but also many of the programmable protection features. Number nonvolatile states Standard Commands for Programmable Instruments (SCPI) SCPI is the standard language for test and measurement equipment. Standard codes make a software writing and maintenance more efficient. For example, using this standard, the output voltage of the power supply is measured with the same command (MEASURE: VOLTAGE?) by either a DMM or a power supply. Protection Features * GPIB LAN USB * * * 4 5 1 2 5 0 0 0 0 * * * * * * * * T * * T M T * * * T * E3630 only T T * * * T * T T * (One of these states is automatically accessed on turn-on) Number volatile states * GPIB LAN USB * For more detailed specifications see the product manual at www.agilent.com/find/power 12 ut tp 120 V 200 V 20 V 60 V 600 V 100 V 875 A 16 A 5A 20 A 180 A 20 A 36, 42 50, 61, 63 76 81 19, 21 26 69 50 V 10 A 10 A Page 23 32, 34 65 67 66 66 66 66 100 V 120 A ut tp s ie er 0S 70 N6 120 V 50 A 500 V Max Current Ou egl in sS ie er 0S 70 N5 50 V 2A Max Voltage tip ul & le ng Si ies er 0S 64 E3 0& E3 63 M un m m Co ile ob M s ie er 0S 30 50 W300 W 40 W & 25 W & 80 W 50 W 66 700 W1500 W 66 30 W 200 W 200 W - 40 W 1000 W 100 W Ou io s em st Sy er w Po ar ul od M 0 00 ic t pu ut -O le ng Si s ie er 0S 69 -6 70 40 at t pu ut -O le Si s rie Se 50 66 & Se 200 W - 2000 W - 1200 W 40 W500 W 6600 W 100 W Max Power le- ns t pu ut le tip ng M n io is ec Pr s rie s rie 20 Se 20 ul pu ut tip ul M Se 30 66 & 10 -O le Si s rie to Au s rie Se 66 30 60 t ut -O le ng s er ng ra (Continued) DC Range -O t pu DC Power Supply Feature Description Index Protection Features (Continued) Discrete fault indicator/ remote inhibit (DFI/RI) Using these digital ports, power supplies can be connected independently of the GPIB. If any one experiences an error condition (overvoltage, for example), it can signal the other units to also downprogram their outputs. O = Optional * * O O * * * * * * SRQ Almost any fault condition or change of state of the power supply can be enabled to generate an SRQ. This signals the computer to take the appropriate action. * * * * * * * * * * Local lockout Front-panel or keyboard control can be disabled. This keeps unauthorized operators from changing the programmed states. * * * * * * * * * * * * * * * * * * * Fan-speed control Controls the fan-speed to provide only the required cooling, reducing unnecessary acoustic noise. O = Optional Active down-programming Active circuits quickly drain the energy from the output when unit is programmed to a lower voltage. This means that a unit under test can be safely removed from its test fixture without danger of arcing. F = Full-rated output current P = Less than 100% rated output current Maintenance Features * P 6610-P 6630-F F F P P P P P N6750 N6760 only * * * * * * * * * * P, S J J P, J P, J P, S P, S P, J *P *P * * * * * * * * * * * Electronic calibration in the rack Calibration requires no internal adjustments. Calibration security Units can be protected from accidental access to calibration routines by either a password (P) or an internal jumper (J ) or switch (s). Self-test Extensive self-test is triggered automatically on power-up. Additional tests can be initialed by user programming or front-panel control. * * *A nonvolatile status in SCPI mode only. For more detailed specifications see the product manual at www.agilent.com/find/power 13 Basic DC Power Supplies... essential features for a tight budget Comparison Summary Agilent Basic DC Power Supplies Agilent High Performance DC Power Supplies Output Power 30 W-1500 W 40 W-6,600 W Number of outputs 1-3 1-8 GPIB programming and measurement speed Moderate Fast Output rise/fall time Moderate Fast Convenient 1/2 rack-size for bench-top use Yes No level of capability. Active Downprogrammer for enhanced test throughput No Yes If you do not need the Stored wake-up state No Yes Programmable Capabilities Moderate Extensive Protection for the DUT Moderate Extensive Agilent Basic DC Power Supplies are the right choice for many applications. They provide quiet, stable DC power for both manual and automatic testing, in R&D and in manufacturing environments, where speed and accuracy are low considerations. At their price level, they have a surprising performance level and features of Agilent High Performance DC Power Supplies, then choose Agilent Basic DC Power Supplies. This summary table will help you decide which family of DC power supplies best meets your needs. More detailed specifications at www.agilent.com/find/power 14 Basic DC Power Supplies essential features for a tight budget Single-Output 30-60 W E3610A-E3617A Small, compact size for bench use Low-noise and excellent regulation Dual-range outputs (E3610A/11A/12A) Specifications E3610A E3611A E3612A E3614A (at 0 to 55 C unless otherwise specified) These linear-regulated DC power supplies provide reliable and convenient DC power on a lab bench. The 10-turn pots and clear voltage and current meters allow fine adjustments to be made easily. These models are CV/CC, so they can serve as either voltage or current sources. The "CC Set" button allows the current setting to be viewed, allowing easy adjustment of a current limit. Either the positive or negative terminal may be connected to ground, creating a positive or negative voltage, or floated up to 240 V from ground. E3610A, E3611A, E3612A These flexible 30 watt DC power supplies have 2 ranges, providing more current at lower voltage levels. E3614A, E3615A, E3616A, E3617A These DC power supplies provide remote sensing to eliminate the errors in voltage regulation due to voltage drops in the load leads. Delicate loads are protected by the overvoltage protection feature. Remote voltage signals can be used to control the power supply's output voltage and current levels. Number of output ranges 2 2 2 1 GPIB No No No No Range 1 0 to 8 V, 0 to 3 A1 0 to 20 V, 0 to 1.5 A1 0 to 60 V, 0 to 0.5 A1 0 to 8 V, 0 to 6 A Range 2 0 to 15 V, 0 to 2 A1 0 to 35 V, 0 to 0.85 A1 0 to 120 V, 0 to 0.25 A1 -- Power (max) 30 W 30 W 30 W 48 W Load and line regulation 0.01% + 2 mV 0.01% + 2 mV 0.01% + 2 mV 0.01% + 2 mV Output ratings1 Ripple and noise from 20 Hz to 20 MHz Voltage rms 200 V 200 V 200 V 200 V peak-peak 2 mV 2 mV 2 mV 1 mV Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Control mode CV/CC CV/CC CV/CC Meter resolution Voltage 10 mV 100 mV 100 mV 10 mV (minimum change using front-panel controls) Current 10 mA 10 mA 1 mA 10 mA 1 CV/CC For 0ff-the-shelf shipment Maximum current is derated 1% per C between 40 to 55C. Application Notes: Understanding Linear Power Supply Operation (AN1554) 5989-2291EN 10 Practical Tips You Need to Know About Your Power Products 5965-8239E More detailed specifications at www.agilent.com/find/E3600 15 Basic DC Power Supplies essential features for a tight budget Single-Output: 30-60 W (Continued) Specifications E3615A E3616A E3617A (at 0 to 55 C unless otherwise specified) Supplemental Characteristics for all model numbers Size: E3610A-E3612A: 91 mm H x 213 mm W x 319 mm D (3.6 in x 8.4 in x 12.6 in); E3614A-E3617A: 91 mm H x 213 mm W x 373 mm D (3.6 in x 8.4 in x 14.7 in) Weight: E3610A-E3612A: 3.8 kg (8.4 lb) net, 5.1 kg (11.3 lb) shipping; E3614A-E3617A: 5.5 kg (12.1 lb) net, 6.75 kg (14.9 lb) shipping Warranty: One year Number of output ranges 1 1 1 GPIB No No No Output ratings1 Range 1 0 to 20 V, 0 to 3 A 0 to 35 V, 0 to 1.7 A 0 to 60 V, 0 to 1 A Range 2 -- -- -- Power (max) 60 W 60 W 60 W Load and line regulation 0.01% + 2 mV 0.01% + 2 mV 0.01% + 2 mV Ripple and noise from 20 Hz to 20 MHz Voltage rms 200 V 200 V 200 V peak-peak 1 mV 1 mV 1 mV Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Control mode CV/CC CV/CC CV/CC Ordering Information Meter resolution Voltage 10 mV (0-20 V), 100 mV (>20 V) 10 mV (0-20 V), 100 mV (>20 V) 10 mV (0-20 V), 100 mV (>20 V) Opt 0E9 90 to 110 Vac, 47 to 63 Hz (Japan only) Opt 0EM 104 to 126 Vac, 47 to 63 Hz Opt 0E3 207 to 253 Vac, 47 to 63 Hz Opt 1CM rack mount kit (E3614A-E3617A only) Opt 0L2 extra documentation package (minimum change using front-panel controls) Current 10 mA 1 mA 1 mA 1 For 0ff-the-shelf shipment Maximum current is derated 1% per C between 40 to 55C. More detailed specifications at www.agilent.com/find/E3600 16 Basic DC Power Supplies essential features for a tight budget Multiple-Output 35 W and 50 W E3620A, E3630A Dual and triple outputs Small, compact size for bench use Low-noise and excellent regulation Overload indicator to monitor output Specifications E3620A E3630A (at 0 to 55 C unless otherwise specified) These linear-regulated DC power supplies provide reliable and convenient DC power on a lab bench. Voltage and current can be monitored simultaneously on the front panel meters. There is also an overload indicator for each output. E3620A The E3620A has two isolated, independent, CV/CL 25 volt outputs. It is easy to make precise adjustments using the 10-turn pots. E3630A The E3630A triple output power supply has two 20 volt outputs and one 6 volt output. The +6V output is an isolated constant-voltage/ current-foldback output, and both the +20 volt output and the -20 volt output are constant-voltage/currentlimit. An autotracking feature lets you use one voltage control to adjust both 20 volt outputs. These outputs track each other to within one percent, making it easy to adjust the power supply for circuits requiring balance voltages. The 20 volt outputs are referenced together to a floating common. Application Notes: Understanding Linear Power Supply Operation (AN1554) 5989-2291EN Number of Outputs 2 3 GPIB No No Output 1 0 to 25 V, 0 to 1 A 0 to 6 V, 0 to 2.5 A* Output 2 0 to 25 V, 0 to 1 A 0 to +20 V, 0 to 0.5 A Output 3 -- 0 to -20 V, 0 to 0.5 A Power (max) 50 W 35 W Load regulation 0.01% + 2mV 0.01% + 2mV Normal mode voltage rms 350 V 350 V peak-to-peak 1.5 mV 1.5 mV Common mode current 1 Arms 1 Arms Control mode CV/CL CV/CL (20 V), CV/CL (6 V) Output ratings* Ripple and noise from 20 Hz to 20 MHz Meter resolution (Minimum change using front-panel controls) Voltage 10 mV (0-20 V), 100 mV, (>20 V) 10 mV Current 1 mA 10 mA Input power 115 Vac 10%, 47 to 63 Hz 115 Vac, 10%, 47 to 63 Hz *Maximum current is derated 3.3% per C from 40C to 55C For off-the-shelf shipment Supplemental Characteristics Ordering Information Size: E3620A: 213 mm W x 91 mm H x 401 mm D (8.4 in x 3.6 in x 15.8 in) E3630A: 213 mm W x 92 mm H x 320 mm D (8.4 in x 3.6 in x 12.6 in) Opt 0E9 90 to 110 Vac, 47 to 63 Hz (Japan only) Opt 0EM 104 to 126 Vac, 47 to 63 Hz Opt 0E3 207 to 253 Vac, 47 to 63 Hz Opt 1CM rack mount kit Opt 0L2 extra documentation package Weight: E3620A: 5.5 kg (12.1 lbs) E3630A: 3.8 kg (8.4 lbs) Warranty: Three years 10 Practical Tips You Need to Know About Your Power Products 5965-8239E More detailed specifications at www.agilent.com/find/E3600 17 Basic DC Power Supplies essential features for a tight budget Triple-Output 80 W GPIB E3631A Small, compact size for bench use Low output ripple and noise Built-in measurements and basic programmable features Over-voltage protection to ensure DUT safety Specifications E3631A (at 0 to 55 C unless otherwise specified) This is the DC power supply for every engineer's or electronic technician's lab bench. It has two tracking 25 V outputs, which are together referenced to a floating common, and an isolated 6 volt output. It is easy to control from the front panel, or with industry standard SCPI commands via the GPIB or RS232. VXIPlug&Play drivers are available to further simplify computer control. Up to 3 complete states can be stored for later recall. The low noise, excellent regulation, and built-in voltmeter/ ammeter make this reliable power supply well suited for the needs of the R&D lab. DC outputs Voltage 0 to +25 V 0 to -25 V 0 to 6 V Current 0 to 1 A 0 to 1 A 0 to 5 A Voltage <0.01% + 2 mV <0.01% + 2 mV <0.01% + 2 mV Current <0.01% + 250 A <0.01% + 250 A <0.01% + 250 A Voltage <0.01% + 2 mV <0.01% + 2 mV <0.01% + 2 mV Current <0.01% + 250 A <0.01% + 250 A <0.01% + 250 A Normal-mode voltage <350 V rms/2 mV p-p <350 V rms/2 mV p-p <350 V rms/2 mV p-p Normal-mode current <500 A rms <500 A rms <2 mA rms Common-mode current <1.5 A rms <1.5 A rms <1.5 A rms Load regulation Line regulation Ripple and noise from 20 Hz to 20 MHz Programming accuracy at 25C 5C Voltage 0.05% + 20 mV 0.05% + 20 mV 0.1% + 5 mV Current 0.15% + 4 mA 0.15% + 4 mA 0.2% + 10 mA Voltage 0.05% + 10 mV 0.05% + 10 mV 0.1% + 5 mV Current 0.15% + 4 mA 0.15% + 4 mA 0.2% + 10 mA Program/readback 1.5 mV, 0.1 mA 1.5 mV, 0.1 mA 0.5 mV, 0.5 mA Meter 10 mV, 1 mA 10 mV, 1 mA 1 mV, 1 mA Transient response 50 sec for output to recover to within 15 mV following a change in output current from full load to half load or vice versa Readback accuracy at 25C 5C Application Notes: Understanding Linear Power Supply Operation (AN1554) 5989-2291EN 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Resolution For off-the-shelf shipment Supplemental Characteristics for all model numbers Product Regulation: Designed to comply with UL1244, IEC 1010-1; certified with CSA 22.2 Meets requirements for CE regulation Software Driver: * IVI-COM * VXIPlug&Play * IntuiLink Connectivity Software Warranty: One year Ordering Information Size: E3631A 213 mm W x 133 mm H x 348 mm D (8.4 in. x 5.2 in. x 14.2 in.) Weight: E3631A 8.2 kg (18 lbs) Opt 0E9 90 to 110 Vac, 47 to 63 Hz (Japan only) Opt 0EM 104 to 126 Vac, 47 to 63 Hz Opt 0E3 207 to 253 Vac, 47 to 63 Hz Opt 1CM rack mount kit Opt 0L2 extra documentation package More detailed specifications at www.agilent.com/find/E3600 18 Basic DC Power Supplies essential features for a tight budget Single-Output 120 W to 200 W GPIB E3632A-E3634A Dual range outputs Small, compact size for bench use Low output ripple and noise Built-in measurements and basic programmable features Protection features to ensure DUT safety Specifications E3632A E3633A E3634A (at 0 to 55 C unless otherwise specified) These dual range DC power supplies provide the stable, accurate, and reliable DC power that the R&D engineer needs. These models are CV/CC, so they can serve as either voltage or current sources. They can be used either for manual or automated testing where moderate speed and accuracy are required. VXIPlug&Play drivers further simplify computer control. Number of Outputs 1 1 1 GPIB Yes Yes Yes Range 1 0 to 15 V, 7 A 0 to 8 V, 20 A 0 to 25 V, 7 A Range 2 0 to 30 V, 4 A 0 to 20 V, 10 A 0 to 50 V, 4 A Voltage <0.01% + 2 mV <0.01% + 2 mV <0.01% + 2 mV Current <0.01% + 250 A <0.01% + 250 A <0.01% + 250 A Voltage <0.01% + 2 mV <0.01% + 2 mV <0.01% + 2 mV Current <0.01% + 250 A <0.01% + 250 A <0.01% + 250 A These DC power supplies have many features to help the R&D engineer to quickly and easily bias and monitor prototype circuitry. Remote sensing eliminates the errors in voltage regulation due to voltage drops in the load leads. Delicate prototypes are protected by overvoltage and overcurrent protection features. Up to 3 frequently used operating states may be stored for later recall. The output is isolated from chassis ground. Ripple and noise from 20 Hz to 20 MHz Normal-mode voltage <350 Vrms/2 mVpp <350 Vrms/3 mVpp <500 Vrms/3 mVp-p Normal-mode current <2 mA rms <2 mA rms <2 mA rms Common-mode current <1.5 A rms <1.5 A rms <1.5 A rms Voltage 0.05% + 10 mV 0.05% + 10 mV 0.05% + 10 mV Current 0.2% +10 mA 0.2% +10 mA 0.2% +10 mA Voltage 0.05% + 5 mV 0.05% + 5 mV 0.05% + 5 mV Current 0.15% + 5 mA 0.15% + 5 mA 0.15% + 5 mA For applications where even higher accuracy is needed, or speed must be optimized, see the Agilent 6600 Series of performance DC power supplies. Output ratings Load regulation Line regulation Programming accuracy at 25C 5C Readback accuracy at 25C 5C Resolution Program 1 mV, 0.5 mA 1 mV, 1 mA 3 mV, 0.5 mA Readback 0.5 mV, 0.1 mA 0.5 mV, 1 mA 1.5 mV, 0.5 mA Meter 1 mV, 1 mA 1 mV, 1 mA (<10 A/10 mA (10 A)) 1 mV, 1 mA (<10 A/10 mA (10 A)) Transient response 50 sec for output to recover to within 15 mV following a change in output current from full load to half load or vice versa *Maximum current is derated 1% per C from 40C to 55C % For off-the-shelf shipment More detailed specifications at www.agilent.com/find/E3600 19 Basic DC Power Supplies essential features for a tight budget Single-Output: 120 W to 200 W (Continued) Application Notes: Understanding Linear Power Supply Operation (AN1554) 5989-2291EN 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Modern Connectivity Using USB and LAN I/O Converters (AN 1475-1) 5989-0123EN Supplemental Characteristics for all model numbers Product Regulation: Designed to comply with UL1244, IEC 61010-1; certified with CSA 22.2 Meets requirements for CE regulation Software Driver: * IVI-COM * VXIPlug&Play * IntuiLink Connectivity Software Warranty: One year Size: 213 mm W x 132 mm H x 348 mm D (8.4 in. x 5.2 in. x 13.7 in.) Weight: 9.5 kg (21 lbs) Ordering Information Opt 0E9 90 to 110 Vac, 47 to 63 Hz (Japan only) Opt 0EM 104 to 126 Vac, 47 to 63 Hz Opt 0E3 207 to 253 Vac, 47 to 63 Hz Opt 1CM rack mount kit Opt 0L2 extra documentation package More detailed specifications at www.agilent.com/find/E3600 20 Basic DC Power Supplies essential features for a tight budget Single & Dual Output 30-100 W GPIB E3640A-E3649A Dual range outputs Small, compact size for bench and system use Low output ripple and noise Built-in measurements and basic programmable features Over-voltage protection to ensure DUT safety Specifications E3640A E3641A E3642A E3643A E3644A Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Voltage Current 0 to 8 V 3A 0 to 35 V 0.8 A 0 to 8 V 5A 0 to 35 V 1.4 A 0 to 8 V 8A Voltage Current 0 to 20 V 1.5 A 0 to 60 V 0.5 A 0 to 20 V 2.5 A 0 to 60 V 0.8 A 0 to 20 V 4A Power (max) 30 W 30 W 50 W 50 W 80 W (at 0 to 55 C unless otherwise specified) These isolated dual range DC power supplies provide the stable and reliable DC power that the manufacturing test system designer needs. These models offer constant-voltage/ constant-current outputs, so they can serve as either voltage or current sources. They can be used either for manual or automated testing, and have VXIPlug&Play drivers to further simplify computer control. The E3640A Series DC power supplies can be quickly integrated into a test system. Both front and rear panel terminals are provided for easy wiring. Remote sensing eliminates the errors in voltage regulation due to voltage drops in the load leads. Delicate DUTs are protected by overvoltage protection. Up to 5 operating states can be stored for later recall. The E3640A Series DC power supplies are intended for manufacturing test systems where moderate speed and accuracy are required. For systems which require even higher accuracy for programming or measurement, or where test throughput must be optimized, consider the Agilent 6600A and N6700 Series of Performance DC Power Supplies. DC outputs Load and line regulation Voltage <0.01% + 3 mV <0.01% + 3 mV <0.01% + 3 mV <0.01% + 3 mV <0.01% + 3 mV Current <0.01% + 250 A <0.01% + 250 A <0.01% + 250 A <0.01% + 250 A <0.01% + 250 A Ripple and noise from 20 Hz to 20 MHz Normal-Mode Voltage <500 Vrms 5 mVp-p <1 mVrms 8 mVp-p <500 Vrms 5 mVp-p <1 mVrms 8 mVp-p <500 Vrms 5 mVp-p Normal-Mode Current <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms Common-Mode Current <1.5 Arms <1.5 Arms <1.5 Arms <1.5 Arms <1.5 Arms Programming accuracy at 25C 5C Voltage <0.05% + 10 mV 10 mV 10 mV 10 mV 10 mV Current <0.2% + 10 mA 10 mA 10 mA 10 mA 10 mA Readback accuracy at 25C 5C Voltage <0.05% + 5 mV 5 mV 5 mV 5 mV 5 mV Current <0.15% + 5 mA 5 mA 5 mA 5 mA 5 mA Voltage 5 mV 5 mV 5 mV 5 mV 5 mV Current 1 mA 1 mA 1 mA 1 mA 1 mA Voltage 2 mV 2 mV 2 mV 2 mV 2 mV Current 1 mA 1 mA 1 mA 1 mA 1 mA Program resolution Readback resolution Meter resolution Voltage 10 mV 10 mV 10 mV 10 mV 10 mV Current 1 mA 1 mA 1 mA 1 mA 1 mA Transient response <50 sec for output to recover to within 15 mV following a change in output current from full load to half load or vice versa. *Maximum current is derated 1% per C from 40C to 55C More detailed specifications at www.agilent.com/find/E3600 21 Basic DC Power Supplies essential features for a tight budget Single & Dual Output: 30-100 W GPIB (Continued) Specifications E3645A E3646A E3647A E3648A E3649A Number of outputs 1 2 2 2 2 GPIB Yes Yes Yes Yes Yes Voltage Current 0 to 35 V 2.2 A 0 to 8 V 3A 0 to 35 V 0.8 A 0 to 8 V 5A 0 to 35 V 1.4 A Voltage Current 0 to 60 V 1.3 A 0 to 20 V 1.5 A 0 to 60 V 0.5 A 0 to 20 V 2.5 A 0 to 60 V 0.8 A Power (max) 80 W 60 W 60 W 100 W 100 W (at 0 to 55 C unless otherwise specified) Application Notes: Understanding Linear Power Supply Operation (AN1554) 5989-2291EN 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Modern Connectivity Using USB and LAN I/O Converters (AN 1475-1) 5989-0123EN Supplemental Characteristics for all model numbers DC Floating Voltage: Output terminals can be floated up to 240 Vdc from chassis ground DC outputs Load and line regulation Voltage <0.01% + 3 mV 3 mV 3 mV 3 mV 3 mV Current <0.01% + 250 A 250 A 250 A 250 A 250 A Normal-Mode Voltage <1 mVrms 8 mVp-p <500 Vrms 5 mVp-p <1 mVrms 8 mVp-p <500 Vrms 5 mVp-p <1 mVrms 8 mVp-p Normal-Mode Current <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms <4.0 mArms Common-Mode Current <1.5 Arms <1.5 Arms <1.5 Arms <1.5 Arms <1.5 Arms Ripple and noise from 20 Hz to 20 MHz Programming accuracy at 25C 5C Voltage <0.05% + (<0.1% + 25 mA for output 2) 10 mV 10 mV 10 mV 10 mV 10 mV Remote Sensing: Up to 1 V can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Current <0.2% + 10 mA 10 mA 10 mA 10 mA 10 mA <0.05% + (<0.1% + 25 mV for output 2) 5 mV 5 mV 5 mV 5 mV 5 mV Settling Time: Less than 90msec for the output voltage to change from 1% to 99% or vice versa following the receipt of VOLTage or APPLy command via direct GPIB or RS-232 interface. Current <0.15% + (<0.15% + 10 mA for output 2) 5 mA 5 mA 5 mA 5 mA 5 mA Voltage 5 mV 5 mV 5 mV 5 mV 5 mV Current 1 mA 1 mA 1 mA 1 mA 1 mA Voltage 2 mV 2 mV 2 mV 2 mV 2 mV Current 1 mA 1 mA 1 mA 1 mA 1 mA Product Regulation: Designed to comply with UL3111-1; certified to CSA 22.2 No. 1010.1; conforms to IEC 1010-1; complies with EMC directive 89/336/EEC(Group1, Class A) Readback accuracy at 25C 5C Voltage Program resolution Readback resolution Meter resolution OVP Accuracy: 0.5% + 0.5 V, activation time: 3 V, <1.5 ms, and <3 V, <10 ms Voltage 10 mV 10 mV 10 mV 10 mV 10 mV Current 1 mA 1 mA 1 mA 1 mA 1 mA Isolation: 240 Vdc Transient response <50 sec for output to recover to within 15 mV following a change in output current from full load to half load or vice versa. Stability: Voltage <0.02% + 2 mV; Current <0.1% + 1 mA *Maximum current is derated 1% per C from 40C to 55C Temperature Coefficient: <0.01% + 3 mV, <0.02% + 3 mA change perC over operating range 0-40C after 30 minute warm-up Size: (E3640A-E3645A) 254.4 mm W x 104 mm H x 374 mm D (10 in. x 4.1 in. x 14.8 in.) (E3646A-E3649A) 213 mm W x 133 mm H x 348 mm D (8.4 in. x 5.2 in. x 13.7 in.) Software Driver: * IVI-COM * VXIPlug&Play * IntuiLink Connectivity Software Warranty Period: One year Weight: E3640A, E3641A: 5.3 kg (11.7 lbs) E3642A, E3643A: 6.2 kg (13.7 lbs) E3644A, E3645A: 6 kg (13.2 lbs) E3646A, E3647A: 7.4 kg (16.3 lbs) E3648A, E3649A: 9.5 kg (20.9 lbs) Ordering Information Opt 0E3 207 to 253 Vac, 47 to 63 Hz Opt 0E9 90 to 110 Vac, 47 to 63 Hz (Japan only) Opt 0EM 104 to 126 Vac, 47 to 63 Hz Opt 1CM Rack mount kit (E3640A-E3645A p/n5063-9240; E3646A-E3649A p/n 5063-9243) Opt 0L2 Extra documentation package Opt 0B0 Delete documentation More detailed specifications at www.agilent.com/find/E3600 22 Basic DC Power Supplies essential features for a tight budget Single-Output, Autoranging 200 W and 1000 W GPIB 6030A, 6031A, 6032A, 6033A, 6035A, 6038A Autoranging outputs provide maximum power at a variety Autoranging Output: of operating voltages P1 V1 Analog/resistance control of output voltage and current P2 Volts V2 Series and auto-parallel connections of multiple supplies V3 Built-in measurements and advanced programmable features I1 I2 Protection features to ensure DUT safety Amps Specifications 6030A 6031A 6032A 6033A 6035A 6038A Number of outputs 1 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Yes Output Voltage 0 to 200 V 0 to 20 V 0 to 60 V 0 to 20 V 0 to 500 V 0 to 60 V Output Current 0 to 17 A 0 to 120 A 0 to 50 A 0 to 30 A 0 to 5 A 0 to 10 A Maximum power watts 1,200 W 1,064 W 1,200 W 242 W 1,050 W 240 W V1, I1 200 V, 5 A 20 V, 50 A 60 V, 17.5 A 20 V, 10 A 500 V, 2 A 60 V, 3.3 A V2, I2 120 V, 10 A 14 V, 76 A 40 V, 30 A 14 V, 17.2 A 350 V, 3 A 40 V, 6 A V3, I3 60 V, 17 A 7 V, 120 A 20 V, 50 A 6.7 V, 30 A 200 V, 5 A 20 V, 10 A Voltage 0.035% +145 mV 0.035% +15 mV 0.035% +40 mV 0.035% +9 mV 0.25% +400 mV 0.035% +40 mV Current 0.2% +25 mA 0.25% +250 mA 0.2% +85 mA 0.15% +20 mA 0.3% +63 mA 0.09% +10 mA Voltage rms p-p 22 mV 50 mV 8 mV 50 mV 8 mV 40 mV 3 mV 30 mV 50 mV 160 mV 3 mV 30 mV Current rms (at 0 to 55 C unless otherwise specified) This series of 200 watt and 1000 watt DC power supplies take the place of multiple power supplies in your test system by providing maximum power at a variety of operating points. Output ratings Autoranging output Industry standard SCPI commands and VXIPlug&Play drivers make system integration easy. Using the serial link, up to 16 power supplies can be connected through one GPIB address. These power supplies have excellent electrical efficiency, making them a good choice for large systems. Programming accuracy at 25C 5C Ripple and noise 20 Hz to 20 MHz Readback accuracy at 25C 5C Application Notes: 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E 15 mA 120 mA 25 mA 30 mA 50 mA 5 mA Voltage 0.08% +80 mV 0.08% +7 mV 0.08% +20 mV 0.07% +6 mV 0.5% +200 mV 0.07% +50 mV Current 0.36% +15 mA 0.4% +100 mA 0.36% +35 mA 0.3% +25 mA 0.5% +50 mA 0.2% +11 mA 0.01%+ 5 mV 3 mV 5 mV 2 mV 40 mV 3 mV 0.01%+ 10 mA 0.01%+ 15 mA 0.01%+ 10 mA 0.01%+ 9 mA 0.03%+ 34 mA 0.01%+ 5 mA Load regulation Voltage 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Current Agilent DC Power Supplies for Base Station Testing 5988-2386EN Voltage 0.01%+ 5 mV 0.01%+ 2 mV 0.01%+ 3 mV 0.01%+ 1 mV 0.03%+ 17 mV 0.01%+ 2 mV Current 0.01%+ 5 mA 0.01%+ 25 mA 0.01%+ 10 mA 0.01%+ 6 mA 0.03%+ 17 mA 0.01%+ 2 mA 2 ms 150 mV 2 ms 100 mV 2 ms 100 mV 1 ms 50 mV 5 ms 200 mV 7 1 ms 5 mV Line regulation Transient response time 10% step change Time Level More detailed specifications at www.agilent.com/find/6030 23 P3 I3 Basic DC Power Supplies essential features for a tight budget Autoranging: 200 W and 1000 W GPIB (Continued) Specifications 6030A 6031A 6032A 6033A 6035A 6038A (at 0 to 55 C unless otherwise specified) Supplemental Characteristics for all model numbers Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Programming resolution Voltage 50 mV 5 mV 15 mV 5 mV 125 mV 1 5 mV 4.25 mA 30 mA 12.5 mA 7.5 mA 1.25 mA 2.5 mA 550 V 240 V 240 V 240 V 550 V 240 V Current Remote Sensing: Up to 2 V drop in each lead. Voltage regulation specification met with up to 0.5 V drop, but degrades for greater drops. DC floating voltage either terminal can be grounded or floated from chassis ground AC input current Modulation: (analog programming of output voltage and current) Input signal: 0 to 5 V or 0 to 4 k Ohms Software Driver: VXIPlug&Play 100 Vac 24 A 24 A 24 A 6A 24 A 6A 120 Vac 24 A 24 A 24 A 6.5 A 24 A 6.5 A 220 Vac 15 A 15 A 15 A 3.8 A 15 A 3.8 A 240 Vac 14 A 14 A 14 A 3.6 A 14 A 3.6 A Net 16.3 kg (36 lb) 17.2 kg (38 lb) 16.3 kg (36 lb) 9.6 kg (21 lb) 16.3 kg (36 lb) 9.6 kg (21 lb) Shipping 21.8 kg (48 lb) 22.7 kg (50 lb) 21.8 kg (48 lb) 11.4 kg (25 lb) 21.8 kg (48 lb) 11.4 kg (25 lb) Weight Warranty: One year Size: 6030A-32A, 6035A: 425.5 mm W x 132.6 mm H x 503.7 mm D (16.75 in x 5.25 in x 19.83 in). 6033A, 6038A: 212.3 mm W x 177.0 mm H x 516.4 mm D (8.36 in x 6.97 in x 17.87 in). Agilent Models: 6030A, 6031A, 6032A, 6035A Top Terminal Strip Detail VM Screw Size M3.5 x 0.6 IM M VP 425mm 16.75" IP P B6 B1 Size 0.6 +S -S 2.5mm 0.1" 421.6mm 16.6" 132.6mm 5.2" 128mm 5.04" 77mm 3.03" Rear Side 12.7mm 0.5" More detailed specifications at www.agilent.com/find/6030 24 12.7mm 0.5" Basic DC Power Supplies essential features for a tight budget Autoranging: 200 W and 1000 W GPIB (Continued) Ordering Information Opt 001 Front panel has only line switch, line indicator, and OVP adjust (6030A-33A and 6038A only) Opt 100 87 to 106 Vac, 48 to 63 Hz (power supply output is derated to 75%) Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 48 to 63 Hz Opt 240 209 to 250 Vac, 48 to 63 Hz Opt 800 Rack-mount Kit for Two Half-rack Units Side by Side. Lock link Kit p/n 5061-9694 and 7 in Rack adapter Kit 5063-9215 * Opt 908 Rack-mount Kit for a Single Half-rack Unit 6033A and 6038A (with blank filler panel); p/n 5062-3960, 6030A-32A and 6035A; p/n 5062-3977 * Opt 909 Rack-mount Kit with Handles. For 6030A-32A, 6035A; p/n 5062-3983 Accessories Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B3 Service Manual Opt 0B0 Full documentation on CD-ROM only Opt J01 Stabilization for loads up to 10 Henries (not available on 6033A) 5080-2148 Serial Link Cable, 2 m (6.6 ft) 1494-0060 Rack Slide Kit E3663AC Support rails for Agilent rack cabinets A line cord option must be specified, see the AC line voltage and cord section. * Support rails required Agilent Models: 6033A, 6038A Terminal Strip Detail VM IM M Top 31.8mm 1.25" VP IP P B6 212.3mm 8.36" B1 Screw Size M3.5 x 0.6 208.8mm 8.22" 19.6mm 0.77" 177.0mm 6.97" 170.6mm 6.72" Rear 13.5mm 0.53" 16.5mm 0.65" 421.6mm 16.6" 22.0mm 0.87" Side More detailed specifications at www.agilent.com/find/6030 25 Basic DC Power Supplies essential features for a tight budget Single-Output 750-1500 W GPIB, LAN, USB, LXI Class C N5741A* Small size: 1 U high Universal AC input (85-265 Vac) Analog/resistance control of output voltage and current Parallel and series connection of multiple supplies 3 N5741A - N5772A Built-in measurements and advanced programmable features Protection features to ensure DUT safety LXI class C compliant Specifications N5741A N5742A N5743A N5744A N5745A N5746A Number of Outputs 1 1 1 1 1 1 GPIB, LAN, USB Yes Yes Yes Yes Yes Yes (at 0 to 40 C unless otherwise specified) The N5700 Series is a family of affordable 750 W and 1500 W switching regulated, single-output programmable DC power supplies. They offer 24 models for simple DC power application where speed and accuracy are not the primary concern. They provide stable output power, built-in voltage and current measurement, and output voltage and current from 6 V to 600 V and 1.3 A to 180 A. Small, High-Density Package The N5700 provides up to 1500 W in a small space-saving 1 U-high, 19-inch wide package. Its air vents are in the front, side and rear (not on the top or bottom), so you can stack other instruments directly above or below it to save valuable rack space. Universal AC input All models have universal AC input so they can be automatically operated from any AC mains input worldwide. They can be operated from line voltages of 85 - 265 VAC, 47 to 63 Hz, with no switch to set or fuses to change when you switch from one voltage standard to another. They also provide power factor correction. Ouput Ratings Voltage 6V 8V 12.5 V 20 V 30 V 40 V Current 100 A 90 A 60 A 38 A 25 A 19 A Power 600 W 720 W 750 W 760 W 750 W 760 W Programming Accuracy Voltage 0.05%+ Current 0.1%+ 3 mV 4 mV 6.25 mV 10 mV 15 mV 20 mV 100 mA 90 mA 60 mA 38 mA 25 mA 19 mA CV p-p (Up to 20 MHz) 60 mV 60 mV 60 mV 60 mV 60 mV 60 mV CV rms (From 5 Hz - 1 MHz) 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV Output Ripple and Noise Readback Accuracy Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV Current 0.1%+ 300 mA 270 mA 180 mA 114 mA 75 mA 57 mA Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 25 mA 23 mA 17 mA 12.6 mA 10 mA 8.8 mA Load Regulation (change from 10% to 90%) Line Regulation (change from 85-132 VAC input or 170-265 VAC input) Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 12 mA 11 mA 8 mA 5.8 mA 4.5 mA 3.9 mA 1.5 ms 1.5 ms 1.5 ms 1 ms 1 ms 1 ms Transient Response Time1 Time Notes: 1 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output * AC input connector: IEC 320 connector for 750 W models, and wire clamp connector for 1500 W models More detailed specifications at www.agilent.com/find/N5700 26 Basic DC Power Supplies essential features for a tight budget Single-Output 750 W & 1500 W GPIB, LAN, USB (Continued) Specifications N5741A N5742A N5743A N5744A N5745A N5746A (at 0 to 40 C unless otherwise specified) Supplemental Characteristics Extensive Device Protection To safeguard your device from damage, the N5700 Series power supplies provide over-temperature, over-current and over-voltage protect (OVP) to shut down the power supply output when a fault occurs. They also offer an undervoltage limit (UVL) that prevents adjustment of the output voltage below a certain limit. The combination of UVL and OVP capabilities lets you create a protection window for sensitive load circuitry (Non-warranted characteristics determined by design that are useful in applying the product) Output Response Time (settle to within 1.0% of the rated output, with a resistive load) Up, full load 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s Down, full load 0.05 s 0.05 s 0.05 s 0.05 s 0.08 s 0.08 s Down, no load 0.5 s 0.6 s 0.7 s 0.8 s 0.9 s 1.0 s 1V 1V 1V 1V 1.5 V 2V 200 mA 180 mA 120 mA 76 mA 63 mA 48 m Voltage 0.72 mV 0.96 mV 1.5 mV 2.4 mV 3.6 mV 4.8 mV Simplify System Connection Current 12 mA 10.8 mA 7.2 mA 4.56 mA 3 mA 2.3 mA The N5700 offers many system oriented features to simplify and accelerate test system development. They support the industry standard SCPI commands and come standard with software drivers. Notes: With built-in GPIB, Ethernet/LAN, and USB 2.0 interfaces, the N5700 gives you the flexibility to use your I/O interface of choice today and in the future. Additionally, the built-in Web server lets you operate, configure, and monitor the N5700 remotely via a standard browser such as Microsoft Internet Explorer. Remote Sense Compensation Volts/load lead Output Ripple and Noise2 CC rms Programming Resolution/ Measurement Resolution 2 From 5 Hz - 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage) Agilent Models: N5741A - N5772A VOLTAGE DC VOLTS N5749A 43.6 mm 100 V / 7.5 A / 750 W Sytem DC Power Supply PROT FINE OVP LIMIT UVL DC AMPS OCP CURRENT REM OUT ON POWER 482.8 mm LINK GPIB J2 SW1 10/100 Ethernet TX +V -V J1 ON OFF +S+LSNC-LC-S 123456789 ANALOG PROGRAMMING The N5700 includes a compatibility command set for the Xantrex XFR series power supplies, the Sorensen DLM series power supplies, and the Agilent 603x series power supplies. This simplifies system integration when converting to the N5700. AC INPUT NOT ACTIVE Command Compatibility 422.8 mm 507.0 mm A A A 21.0 mm 57.8 mm 92.0 mm 92.0 mm 433.0 mm More detailed specifications at www.agilent.com/find/N5700 27 Basic DC Power Supplies essential features for a tight budget Single-Output 750 W & 1500 W GPIB, LAN, USB (Continued) Specifications N5747A N5748A N5749A N5750A N5751A N5752A Number of Outputs 1 1 1 1 1 1 GPIB, LAN, USB Yes Yes Yes Yes Yes Yes (at 0 to 40 C unless otherwise specified) Analog/Resistance Programming For greater programming flexibility and to minimize the time associated with computer interaction, both the output voltage and current can be controlled by an external voltage or resistance programming signal. Connect Multiple Units in Parallel and Series Should you need greater output power, the N5700 Series power supplies give you the flexibility to connect in parallel up to four similarly rated units for greater output current and connect two similarly rated units in series for greater output voltage (see DC float voltage information) Fan Speed Control Lab bench use is enhanced by the fan speed control, which helps to minimize the acoustic noise. Ouput Ratings Voltage 60 V 80 V 100 V 150 V 300 V 600 V Current 12.5 A 9.5 A 7.5 A 5A 2.5 A 1.3 A Power 750 W 760 W 750 W 750 W 750 W 780 W Programming Accuracy Voltage 0.05%+ Current 0.1%+ 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV 12.5 mA 9.5 mA 7.5 mA 5 mA 2.5 mA 1.3 mA Output Ripple and Noise CV p-p (Up to 20 MHz) 60 mV 80 mV 80 mV 100 mV 150 mV 300 mV CV rms (From 5 Hz - 1 MHz) 8 mV 8 mV 8 mV 12 mV 20 mV 60 mV Readback Accuracy Voltage 0.1%+ 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV Current 0.1%+ 37.5 mA 28.5 mA 22.5 mA 15 mA 7.5 mA 3.9 mA Load Regulation (change from 10% to 90%) Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Current 7.5 mA 6.9 mA 6.5 mA 6 mA 5.5 mA 5.26 mA Line Regulation (change from 85-132 VAC input or 170-265 VAC input) Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Current 3.25 mA 2.95 mA 2.75 mA 2.5 mA 2.25 mA 2.13 mA 1 ms 1 ms 2 ms 2 ms 2 ms Transient Response Time1 Application Notes: Time 1 ms Side-by-Side Comparison: Agilent N5700 System DC Source and Sorensen DLM Power Supply 5989-1628EN Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying the product) Side-by-Side Comparison: Agilent N5700 System DC Source and Xantrex XFR DC Power Supply 5989-1630EN Trends in Programmable Medium Power (~1 kW) System DC Power Supplies 5989-1331EN Output Response Time (settle to within 1.0% of the rated output, with a resistive load) Up, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.25 s Down, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.30 s Down, no load 1.1 s 1.2 s 1.5 s 2.0 s 3.0 s 4.0 s 3V 4V 5V 5V 5V 5V 38 mA 29 mA 23 mA 18 mA 13 mA 8 mA Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV Current 1.5 mA 1.14 mA 0.9 mA 0.6 mA 0.3 mA 0.156 mA Remote Sense Compensation Volts/load lead Output Ripple and Noise2 CC rms Notes: 1 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output Programming Resolution/ Measurement Resolution 2 From 5 Hz - 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage) More detailed specifications at www.agilent.com/find/N5700 28 Basic DC Power Supplies essential features for a tight budget Single-Output 750 W & 1500 W GPIB, LAN, USB (Continued) Specifications N5761A N5762A N5763A N5764A N5765A N5766A Number of Outputs 1 1 1 1 1 1 GPIB, LAN, USB Yes Yes Yes Yes Yes Yes (at 0 to 40 C unless otherwise specified) Supplemental Characteristics for all model numbers Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 55 ms. Ouput Ratings Voltage 6V 8V 12.5 V 20 V 30 V 40 V Current 180 A 165 A 120 A 76 A 50 A 38 A Power 1080 W 1320 W 1500 W 1520 W 1500 W 1520 W Programming Accuracy Voltage 0.05%+ DC Floating Voltage: Current 0.1%+ 6 V to 60 V units No output terminal may be more than 60 VDC from any other terminal or chassis ground Output Ripple and Noise 80 V to 600 V units No output terminal may be more than 600 VDC from any other terminal or chassis ground Modulation: (Analog programming of output voltage and current) Input Signal: selectable, 0 to 5 V/0 to 10 V full scale Input Impedance: selectable, 0 to 5 k/0 to 10 k full scale I/O Interface: GPIB, LAN, USB standard * LabVIEW AC Input: Input Range: 85 - 265 VAC; 47 - 63 Hz 4 mV 6.25 mV 10 mV 15 mV 20 mV 165 mA 120 mA 76 mA 50 mA 38 mA CV p-p (Up to 20 MHz 60 mV 60 mV 60 mV 60 mV 60 mV 60 mV CV rms (From 5 Hz - 1 MHz 8 mV 8 mV 8 mV 8 mV 8 mV 8 mV Readback Accuracy Voltage 0.1%+ 6 mV 8 mV 12.5 mV 20 mV 30 mV 40 mV Current 0.1%+ 540 mA 495 mA 360 mA 228 mA 150 mA 114 mA Load Regulation (change from 10% to 90%) Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 41 mA 38 mA 29 mA 20.2 mA 15 mA 12.6 mA Line Regulation (change from 85-132 VAC input or 170-265 VAC input) Voltage 2.6 mV 2.8 mV 3.25 mV 4 mV 5 mV 6 mV Current 20 mA 18.5 mA 14 mA 9.6 mA 7 mA 5.8 mA Time 1.5 ms 1.5 ms 1.5 ms 1 ms 1 ms 1 ms Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying the product) Transient Response Time1 Software Driver: * IVI-COM 3 mV 180 mA Output Response Time (settle to within 1.0% of the rated output, with a resistive load) Up, full load 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s 0.08 s Input Current 750 W: 10.5 A at 100 VAC nominal; 5 A at 200 VAC nominal Down, full load 0.05 s 0.05 s 0.05 s 0.05 s 0.08 s 0.08 s Input Current 1500 W: 21 A at 100 VAC nominal; 11 A at 200 VAC nominal Down, no load 0.5 s 0.6 s 0.7 s 0.8 s 0.9 s 1.0 s Remote Sense Compensation 1V 1V 1V 1V 1.5 V 2V 360 mA 330 mA 240 mA 152 mA 125 mA 95 mA Voltage 0.72 mV 0.96 mV 1.5 mV 2.4 mV 3.6 mV 4.8 mV Current 21.6 mA 19.8 mA 14.4 mA 9.12 mA 6 mA 4.6 mA Volts/load lead Output Ripple and Noise2 CC rms Notes: 1 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output Programming Resolution/ Measurement Resolution 2 From 5 Hz - 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage) More detailed specifications at www.agilent.com/find/N5700 29 Basic DC Power Supplies essential features for a tight budget Single-Output 750 W & 1500 W GPIB, LAN, USB (Continued) Specifications N5767A N5768A N5769A N5770A N5771A N5772A Number of Outputs 1 1 1 1 1 1 GPIB, LAN, USB Yes Yes Yes Yes Yes Yes (at 0 to 40 C unless otherwise specified) Power Factor: 0.99 at nominal input and rated output power Regulatory Compliance: European EMC directive 89/336/EEC for Class A products, Australian C-Tick mark, This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canada. European Low Voltage Directive 73/23/EEC. Ouput Ratings Voltage 60 V 80 V 100 V 150 V 300 V 600 V Current 25 A 19 A 15 A 10 A 5A 2.6 A Power 1500 W 1520 W 1500 W 1500 W 1500 W 1560 W Programming Accuracy Voltage 0.05%+ 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV Current 0.1%+ 25 mA 19 mA 15 mA 10 mA 5 mA 2.6 mA Output Ripple and Noise Size: 43.6 mm H x 422.8 mm W x 432.8 mm D (1.72 in x 16.65 in x 17.04 in), excluding connectors and handles CV p-p (Up to 20 MHz) 60 mV 80 mV 80 mV 100 mV 150 mV 300 mV CV rms (From 5 Hz - 1 MHz) 8 mV 8 mV 8 mV 12 mV 20 mV 60 mV Weight: Net, 750 W - 7 Kg (15.4 lbs); 1500 W - 8.5 Kg (18.7 lbs) Voltage 0.1%+ 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV Current 0.1%+ 75 mA 57 mA 45 mA 30 mA 15 mA 7.8 mA Warranty Period: One year Load Regulation (change from 10% to 90%) Ordering Information Readback Accuracy Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Current 10 mA 8.8 mA 8 mA 7 mA 6 mA 5.5 mA Opt 900 Power Cord, United Kingdom Line Regulation (change from 85-132 VAC input or 170-265 VAC input) Opt 902 Power Cord, Europe Voltage 8 mV 10 mV 12 mV 17 mV 32 mV 62 mV Opt 903 Power Cord, USA, Canada Current 4.5 mA 3.9 mA 3.5 mA 3 mA 2.5 mA 2.26 mA Opt 918 Power Cord, Japan Transient Response Time1 Opt 922 Power Cord, China Time 1 ms 1 ms 1 ms 2 ms 2 ms 2 ms Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) For N574x and N575x (750 W Models) For N576x and N577x (1500 W Models) Opt 861 Unterminated Power Cord, USA, Canada, China, Japan, Other Opt 862 Harmonized Unterminated Power Cord, Europe Output Response Time (settle to within 1.0% of the rated output, with a resistive load) Up, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.25 s Accessories for all N5700 Models Down, full load 0.08 s 0.15 s 0.15 s 0.15 s 0.15 s 0.30 s N5740A Rack Mount Slide Kit (required for rack mounting; standard system II rack mounting hardware will not work). Down, no load 1.1 s 1.2 s 1.5 s 2.0 s 3.0 s 4.0 s 3V 4V 5V 5V 5V 5V 75 mA 57 mA 45 mA 35 mA 25 mA 12 mA Voltage 7.2 mV 9.6 mV 12 mV 18 mV 36 mV 72 mV Current 3 mA 2.28 mA 1.8 mA 1.2 mA 0.6 mA 0.312 mA Remote Sense Compensation Volts/load lead Output Ripple and Noise2 CC rms Notes: 1 Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. Voltage set point from 10% to 100% of rated output Programming Resolution/ Measurement Resolution 2 From 5 Hz - 1 MHz, at 10% to 100% of output voltage at full load (for 6 V units from 33% to 100% of output voltage) More detailed specifications at www.agilent.com/find/N5700 30 High Performance DC Power Supplies... speed and accuracy for test optimization Comparison Summary Agilent Basic DC Power Supplies Agilent High Performance DC Power Supplies Output Power 30 W-1500 W 40 W-6600 W Number of outputs 1-3 1-8 GPIB programming and measurement speed Moderate Fast Output rise/fall time Moderate Fast Convenient 1/2 rack-size for bench-top use Yes No achieve their goals. Active Downprogrammer for enhanced test throughput No Yes Multiple output power supplies Stored wake-up state No Yes Programmable Capabilities Moderate Extensive Protection for the DUT Moderate Extensive Agilent Performance DC Power Supplies provide the features and performance necessary to satisfy the most demanding requirements. For system designers who are striving to shorten test time and maximize production throughput, the Agilent High Performance DC power supplies will help them reduce rack space. The advanced programmable capabilities allow for efficient system design and maintenance. Also their programming and measurement accuracy, and their DUT protection features, make them an excellent value for the R&D lab. More detailed specifications at www.agilent.com/find/power 31 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 40-50 W GPIB 6611C - 6614C Small, compact size for bench and system use Fast, low-noise outputs Dual-range, precision low current measurement Built-in measurements and advanced programmable features Protection features to ensure DUT safety Specifications 6611C 6612C 6613C 6614C (at 0 to 55 C unless otherwise specified) This series of linear-regulated 40-50 W DC power supplies is designed to maximize the throughput of DUTs through the manufacturing test process with fast programming and measurement, and also active downprogramming. It offers many advanced programmable features including stored states and status reporting. Programming is done using industry standard SCPI commands via the GPIB or RS-232. Test system integration is further simplified by using the VXIPlug&Play drivers. The optional relays simplify system design and troubleshooting. The half-rack size of the 6610A series makes it a convenient DC power supply for the R&D lab bench. The built-in microamp measurement system helps the engineer to easily and accurately monitor the output voltage and current without a complicated test setup. 6611CJ05 Special Order Option Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Voltage 0 to 8 V 0 to 20 V 0 to 50 V 0 to 100 V 0 to 10 V Current 0 to 5 A 0 to 2 A 0 to 1 A 0 to 0.5 A 0 to 5 A Output Ratings Programming accuracy (at 25C 5C) Voltage +Current 0.05% + 5mV 10 m V 20 m V 50 m V 5mV 2mA 1mA 0.75 m A 0.5 m A 2mA 0.5 mV 3 mV 0.5 mV 3 mV 0.5 mV 4 mV 0.5 mV 5 mV 0.5 mV 3 mV 2 mA 1 mA 1 mA 1 mA 2 mA Ripple and noise 20 Hz to 20 MHz, with outputs ungrounded or with either terminal grounded Voltage rms peak -to-peak Normal mode rms DC measurement accuracy via GPIB or front-panel meters with respect to actual output at 25C 5C Voltage 0.03% + 2 mV 3 mV 6 mV 12 mV 2 mV Low current range -20 mA to + 20 mA 0.1% + 2.5 A 2.5 A 2.5 A 2.5 A 2.5 A High current range +20 mA to + rated 1 -20 mA to - rated 1 0.2% + 0.2% + 0.5 mA 1.1 mA 0.25 mA 0.85 mA 0.2 mA 0.8 mA 0.1 mA 0.7 mA 0.5 mA 1.1 mA Voltage 2 mV 2 mV 4 mV 5 mV 2 mV Current 1 mA 0.5 mA 0.5 mA 0.5 mA 1 mA Voltage 0.5 mV 0.5 mV 1 mV 1 mV 0.5 mV Current 0.5 mA 0.5 mA 0.25 mA 0.25 mA 0.5 mA Load regulation Line regulation Transient response time Less than 100 s for the output to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of the output current rating of the supply Application Notes: Supplemental Characteristics 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Average programming resolution 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E (Non-warranted characteristics determined by design and useful in applying the product) Voltage 2 mV 5 mV 12.5 mV 25 mV Current 1.25 mA 0.5 mA 0.25 mA 0.125 mA 3 mV 1.25 mA Sink current 3A 1.2 A 0.6 A 0.3 A 3A Understanding Linear Power Supply Operation (AN1554) 5989-2291EN More detailed specifications at www.agilent.com/find/6610 32 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 40-50 W GPIB (Continued) Ordering Information Supplemental Characteristics for all model numbers DC Floating Voltage: Output terminals can be floated up to 240 Vdc maximum from chassis ground Remote Sensing: Up to two volts dropped in each load lead. Add 2 mV to the voltage load regulation specification for each one volt change in the postive output lead due to load current change. Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital date is 4 ms for the power supplies connected directly to the GPIB. Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 2 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 6 ms. Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 230 207 to 253 Vac, 47 to 63 Hz Opt 760 Isolation and Reversal relays * Opt ICM Rack-mount Kit (p/n 5063-9240) * Opt AXS Rack-mount Kit side-by-side mounting of two units, Lock-link Kit p/n 5061-9694; Flange Kit p/n 5062-3974 Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual *Support rails required Accessories Rack-mount and slide for two side-by-side units of different lengths p/n 1494-0015, 5063-9255 and filler panel 5002-3999 Rack-mount slide and support for one instrument p/n 1494-0015, 5063-9255 and filler panel 5002-3999 E3663AC Support rails for Agilent rack cabinets Agilent Models: 6611C, 6612C, 6613C, 6614C GPIB Interface Capabilities: IEEE-488.2, SCPI command set, and 6630A Series programming compatability Top 368.3mm 14.5" Input Power: (full load): 1.6 A, 100 W (6611C: 2.2 A, 120 W) Regulatory Compliance: Complies with EMC directive 89/336/EEC (ISM 1B). Software Driver: VXIPlug&Play 212.8mm 8.4" Warranty Period: One year Size: 212.8 mm W x 88.1 mm H x 368.3 mm D (8.4 in x 3.5 in x 14.5 in) Weight: 8.2 kg (18.16 lb) net; 10.6 kg (23.5 lb) shipping 88.1mm 3.5" 88.1mm 3.5" 368.3mm 14.5" Rear Side More detailed specifications at www.agilent.com/find/6610 33 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 80-100 W GPIB Fast, low-noise outputs Programmable active down-programmer sinks the full rated current Dual-range, precision low current measurement Optional isolation and polarity reversal relays Built-in measurements and advanced programmable features 6631B - 6634B Protection features to ensure DUT safety Specifications 6631B 6632B 6633B 6634B Number of outputs 1 1 1 1 GPIB Yes Yes Yes Yes Voltage 0 to 8 V 0 to 20 V 0 to 50 V 0 to 100 V Current 0 to 10 A 0 to 5 A 0 to 2 A 0 to 1 A 5 mV 10 mV 20 mV 50 mV 4 mA 2 mA 1 mA 0.5 mA (at 0 to 55 C unless otherwise specified) This series of linear-regulated 80-100 W DC power supplies is designed to maximize the throughput of DUTs through the manufacturing test process. Both programming and measurement are optimized for speed. The active downprogrammer can sink up to the full rated current of the power supply, which quickly brings the power supply output to zero volts. The 6630B Series offers many advanced programmable features including stored states and status reporting. Programming is done using industry standard SCPI commands via the GPIB or RS-232. Test system integration is further simplified by using the VXIPlug&Play drivers. The optional relays simplify system design and troubleshooting. Output ratings Programming accuracy at 25C 5C Voltage + Current 0.05% + Ripple and noise (20 Hz to 20 MHz, with outputs ungrounded or with either terminal grounded) Voltage Normal mode rms peak-to-peak 0.3 mV 3 mV 0.3 mV 3 mV 0.5 mV 3 mV 0.5 mV 3 mV Fast mode rms peak-to-peak 1 mV 10 mV 1 mV 10 mV 1 mV 15 mV 2 mV 25 mV rms 3 mA 2 mA 2 mA 2 mA Current DC measurement accuracy via GPIB or front panel meters with respect to actual output at 25C 5C Voltage 0.03% + 2 mV 3 mV 6 mV 12 mV Low current range -20 mA to +20 mA 0.1% + 2.5 A 2.5 A 2.5 A 2.5 A High current range +20 mA to + rated I -20 mA to -rated I 0.2% + 0.2% + 1 mA 1.6 mA 0.5 mA 1.1 mA 0.25 mA 0.85 mA 0.25 mA 0.85 mA Voltage 2 mV 2 mV 4 mV 5 mV Current 2 mA 1 mA 1 mA 1 mA Voltage 0.5 mV 0.5 mV 1 mV 1 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA Load regulation The optional front panel binding posts make the 6630B Series convenient on the R&D lab bench. The built-in microamp measurement system helps the engineer to easily and accurately monitor the output voltage and current without a complicated test setup. Line regulation Transient response time Less than 100 s (50 s in the fast mode) for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV) following any step change in load current of up to 50% of the output current rating of the supply. Application Notes: 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Understanding Linear Power Supply Operation (AN1554) 5989-2291EN 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E More detailed specifications at www.agilent.com/find/6630 34 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 80-100 W GPIB (Continued) Specifications 6631B 6632B 6633B 6634B (at 0 to 55 C unless otherwise specified) Supplemental Characteristics Supplemental Characteristics for all model numbers (Non-warranted characteristics determined by design and useful in applying the product) Average programming resolution Voltage 2 mV 5 mV 12.5 mV DC Floating Voltage: Output terminals can be floated up to 240 Vdc maximum from chassis ground Current 2.5 mA 1.25 mA 0.5 mA 0.25 mA Sink current 10 A 5A 2A 1A Remote Sensing: Up to two volts dropped in each load lead. Add 2 mV to the voltage load regulation specification for each one volt change in the positive output lead due to load current change. SCPI mode 0.4% + 4 mA 0.4% + 2 mA 0.4% + 1 mA 0.4% + 0.5 mA Compatability mode -500 mA -250 mA -100 mA -50 mA Minimum current in constant current mode* 40 mA 20 mA 8 mA 4 mA Command-Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 4 ms for the power supplies connected directly to the GPIB. (Display disabled). Output-Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 2 ms (400 s in fast mode). The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 6 ms (2 ms in the fast mode). GPIB Interface Capabilities: IEEE-488.2, SCPI command set and 6630A Series programming compatability Software Driver: VXIPlug&Play Measurement Time: Average time to make a voltage or current measurement is 50 ms. 25 mV Sink current tracking *When programming in the 6630A Series language compatibility mode. Ordering Information Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 230 207 to 253 Vac, 47 to 63 Hz Opt 020 Front-panel Binding Posts (N/A on 6631B) Opt 760 Isolation and Reversal Relays, only available at time of order (N/A on 6631B) * Opt 1CM Rack-mount Kit, p/n 5063-9212 * Opt 1CP Rack-mount Kit with Handles, p/n 5063-9219 Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Accessories p/n 1494-0060 Rack Slide Kit E3663AC Support rails for Agilent rack cabinets Agilent Models: 6631B, 6632B, 6633B, 6634B Top 364.4mm 14.3" Input Power (full load): 3.5 A, 250 W Regulatory Compliance: Complies with EMC directive 89/336/EEC (ISM 1B). Warranty Period: One year Size: 425.5 mm W x 88.1 mm H x 364.4 mm D (16.8 in x 3.5 in x 14.3 in). Weight: Net, 12.7 kg (28 lb) net; 15.0 kg (33 lb) shipping Terminal Strip Detail Output 2 & 3 +S + - -S Screw Size: M35 x 0.6 88.1mm 3.5" 100mm 3.93" 425.4mm 16.75" Side Rear More detailed specifications at www.agilent.com/find/6630 35 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 200 W GPIB Fast, low-noise outputs Analog control of output voltage and current Fan-speed control to minimize acoustic noise Parallel and series connections of multiple units Built-in measurements and advanced programmable features 6641A - 6645A Protection features to ensure DUT safety Specifications 6641A 6642A 6643A 6644A 6645A Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V Output current (40 C) 0 to 20 A 0 to 10 A 0 to 6 A 0 to 3.5 A 0 to 1.5 A Maximum current (50 C/55 C) 18 A/17 A 9 A/8.5 A 5.4 A/5.1 A 3.2 A/3 A 1.4 A/1.3 A (at 0 to 55 C unless otherwise specified) This series of 200 W linear-regulated DC power supplies is designed to maximize the throughput of DUTs through the manufacturing test process with fast up and down programming time. Valuable assemblies can be destroyed by a minor component failure that can allow a surge of voltage or current to flow to the DUT. Fast protection features, including fast crowbar, mode crossover protection, and the ability to connect the protection circuitry of multiple power supplies can increase production yield. Programming of the DC output and the protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified be using the VXIPlug&Play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes. Lab bench use is enhanced by the fan speed control, which helps to minimize the acoustic noise. Output ratings Programming accuracy at 25C 5C Voltage 0.06% + 5 mV 10 mV 15 mV 26 mV 51 mV Current 0.15% + 26 mA 13 mA 6.7 mA 4.1 mA 1.7 mA rms 300 V 300 V 400 V 500 V 700 V 3 mV 3 mV 4 mV 5 mV 7 mV 10 mA 5 mA 3 mA 1.5 mA 1 mA 80 mV Ripple and noise from 20 Hz to 20 MHz Voltage peak-peak Current rms Readback accuracy at 25C 5C (percent of reading plus fixed) Voltage 0.07% + 6 mV 15 mV 25 mV 40 mV +Current 0.15% + 18 mA 9.1 mA 5 mA 3 mA 1.3 mA -Current 0.35% + 40 mA 20 mA 12 mA 6.8 mA 2.9 mA Voltage 1 mV 2 mV 3 mV 4 mV 5 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA Voltage 0.5 mV 0.5 mV 1 mV 1mV 2 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA Load regulation Line regualtion Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 2 mV 5 mV 10 mV 15 mV Current 6 mA 3 mA 2 mA 1.2 mA 30 mV 0.5 mA OVP 13 mV 30 mV 54 mV 93 mV 190 mV OVP accuracy 160 mV 400 mV 700 mV 1.2 V 2.4 V More detailed specifications at www.agilent.com/find/6640 36 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 200 W GPIB (Continued) Specifications 6641AJ04 6643AJ11 6644AJ09 6645AJ05 6645AJ06 Special Order Option Special Order Option Special Order Option Special Order Option Special Order Option Number of Outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Output voltage 13 V 40 V 70 V 150 V 170 V Output current (40C) 15.3 A 5A 3A 1.2 A 1A Maximum current (50C/55C) 13.77 A/13 A 4.5 A/4.25 A 2.7 A/2.55 A 1.08 A/1.02 A 0.9 A/0.85 A (at 0 to 55 C unless otherwise specified) Application Notes: 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Output ratings 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E Programming accuracy at 25C 5C Understanding Linear Power Supply Operation (AN1554) 5989-2291EN Ripple and noise Modern Connectivity Using USB and LAN I/O Converters (AN 1475-1) 5989-0123EN Supplemental Characteristics for all model numbers Voltage 0.06% + 8.5 mV 17.5 mV 31 mV 65 mV 74 mV Current 0.15% + 21 mA 6.7 mA 4.1 mA 1.7 mA 1.7 mA from 20 Hz to 20 MHz Voltage 300 V 450 V 600 V 900 V 1 mV peak-peak rms 3 mV 3.5 mV 6 mV 9 mV 10 mV Current rms 8 mA 3 mA 1.5 mA 1 mA 1 mA Readback accuracy at 25C 5C (percent of reading plus fixed) Voltage 0.07% + 10 mV 30 mV 47 mV 100 mV 140 mV +Current 0.15% + 15 mA 5 mA 3 mA 1.3 mA 1.3 mA -Current 0.35% + 40 mA 12 mA 6.8 mA 2.9 mA 2.9 mA Load regulation DC Floating Voltage: Output terminals can be floated up to 240 Vdc from chassis ground Voltage 1 mV 3 mV 4.5 mV 7 mV 8 mV Current 1 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Voltage 0.5 mV 1 mV 1.5 mV 2.5 mV 3 mV Current 1 mA 0.25 mA 0.25 mA 0.25 mA 0.25 mA Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the GPIB Supplemental Characteristics Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms. Line regulation Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 3.5 mV 12 mV 1.4 mV 37.5 mV Current 5 mA 2 mA 1.2 mA 0.5 mA 42.5 mV 0.5 mA OVP 23 mV 62 mV 110 mV 250 mV 285 mV OVP accuracy 260 mV 800 mV 1.5 mV 3V 3.4 V Down Programming: An active down programmer sinks approximately 20% of the rated output current Modulation: (Analog programming of output voltage and current) Input Signal: 0 to -5 V Input Impedance: 10 k Ohm nominal More detailed specifications at www.agilent.com/find/6640 37 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 200 W GPIB (Continued) AC Input: (AC input frequency 47 to 63 Hz) Voltage 100 Vac 120 Vac 220 Vac 240 Vac Current 4.4 A 3.8 A 2.2 A 2.0 A Input Power 480 VA, 400 W at full load; 60 W at no load GPIB Interface Capabilities SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI-compatible command set Software Driver: *IVI-COM *VXIPlug&Play Regulatory Compliance: Complies with UL 3111-1, IEC 61010-1. Size: 425.5 mm W x 88.1 mm H x 439 mm D (16.75 in x 3.5 in x 17.3 in) Ordering Information Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 240 209 to 250 Vac, 47 to 63 Hz * Opt 908 Rack-mount Kit (p/n 5063-9212) * Opt 909 Rack-mount Kit w/ Handles (p/n 5063-9219) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Accessories p/n 1494-0060 Accessory Slide Kit p/n 1252-3698 7-pin Analog Plug p/n 1252-1488 4-pin Digital Plug p/n 5080-2148 Serial Link Cable 2 m (6.6 ft) E3663AC Support rails for Agilent rack cabinets Weight: Net, 14.2 kg (31.4 lb); shipping, 16.3 kg (36 lb) Warranty Period: One year Agilent Models: 6641A, 6642A, 6643A, 6644A, 6645A Top 421.7mm 16.6" + - 240 Vdc Max to + - 425.5mm 16.75" 6 - 32 x 3/8 Screws { A Thomas & Betts 22-18 ring crimp-on will fit in this area } Terminal Screw Size: m4 x 0.7 x 8mm 434.3mm 17.1" 12.7mm 0.5" 88.1mm 3.5" Rear 100mm 3.93" Side Output More detailed specifications at www.agilent.com/find/6640 38 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 200 W 6541A-6545A Front panel and analog control of output voltage and current Fast, low-noise outputs Fan-speed control to minimize acoustic noise Protection features to ensure DUT safety Specifications 6541A 6542A 6543A 6544A 6545A (at 0 to 55 C unless otherwise specified) This reliable series of 200 W DC power supplies can be controlled either from the front panel or via an analog programming voltage. When used in a test system, the fast up and down programming helps decrease test time. Quickly reacting protection features, including fast crowbar, CV/CC mode crossover and over-voltage protection help protect your valuable assemblies from damage. The linear topology produces very low ripple and noise, which allows you to make extremely accurate measurements of the devices which you are testing. Lab bench use is enhanced by the fan speed control, which helps to minimize the acoustic noise. Number of outputs 1 1 1 1 1 GPIB No No No No No Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V Output current (40 C) 0 to 20 A 0 to 10 A 0 to 6 A 0 to 3.5 A 0 to 1.5 A Maximum current (50 C/55 C) 18 A/17 A 9 A/8.5 A 5.4 A/5.1 A 3.2 A/3 A 1.4 A/1.3 A Output ratings Programming accuracy at 25C 5C Voltage 0.06% + 5 mV 10 mV 15 mV 26 mV 51 mV Current 0.14% + 26 mA 13 mA 6.7 mA 4.1 mA 1.7 mA Ripple and noise from 20 Hz to 20 MHz Voltage rms 300 V 300 V 400 V 500 V 700 V peak-peak 3 mV 3 mV 4 mV 5 mV 7 mV Current rms 10 mA 5 mA 3 mA 1.5 mA 1 mA Voltage 1 mV 2 mV 3 mV 4 mV 5 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA Voltage 0.5 mV 0.5 mV 1 mV 1mV 2 mV Current 1 mA 0.5 mA 0.25 mA 0.25 mA 0.25 mA Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Load regulation Line regulation Average resolution Voltage 2 mV 5 mV 10 mV 15 mV Current 6 mA 3 mA 2 mA 1.2 mA 30 mV 0.5 mA OVP 13 mV 30 mV 54 mV 93 mV 190 mV OVP accuracy 160 mV 400 mV 700 mV 1.2 V 2.4 V More detailed specifications at www.agilent.com/find/6540 39 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 200 W (Continued) Specifications (at 0 to 55 C unless otherwise specified) Application Notes: 6541AJ04 6544AJ09 6545AJ05 Special Order Option Special Order Option Special Order Option Number of outputs 1 1 1 GPIB No No No 150 V Output ratings 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Output voltage 13 V 70 V Output current (40 C) 15.3 A 3A 1.2 A Maximum current (50 C/55 C) 13.77 A/13 A 2.7 A/2.55 A 1.08 A/1.02 A Understanding Linear Power Supply Operation (AN1554) 5989-2291EN Programming accuracy at 25C 5C Voltage 0.06% + 8.5 mV 31 mV 65 mV Current 0.15% + 21 mA 4.1 mA 1.7 mA Ripple and noise Supplemental Characteristics for all model numbers from 20 Hz to 20 MHz DC Floating Voltage: Output terminals can be floated up to 240 Vdc from chassis ground Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms. Down Programming: An active down programmer sinks approximately 20% of the rated output current Modulation: (Analog programming of output voltage and current) Input Signal: 0 to -5 V Input Impedance: 10 k Ohm nominal Voltage rms 300 V 600 V 900 V peak-peak 3 mV 6 mV 9 mV Current rms 8 mA 1.5 mA 1 mA Voltage 1 mV 4.5 mV 7 mV Current 1 mA 0.25 mA 0.25 mA Voltage 0.5 mV 1.5 mV 2.5 mV Current 1 mA 0.25 mA 0.25 mA Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Load regulation Line regulation Average resolution Voltage 3.5 mV 1.4 mV 37.5 mV Current 5 mA 1.2 mA 0.5 mA OVP 23 mV 110 mV 250 mV OVP accuracy 260 mV 1.5 mV 3V AC Input: (AC input frequency 47 to 63 Hz) Voltage Current 100 Vac 120 Vac 220 Vac 4.4 A 3.8 A 2.2 A 240 Vac 2.0 A Input Power: 480 VA, 400 W at full load; 60 W at no load Regulatory Compliance: Conforms to UL1244 and IEC 61010-1. Size: 425.5 mm W x 88.1 mm H x 439 mm D (16.75 in x 3.5 in x 17.3 in) Weight: Net, 14.2 kg (31.4 lb); shipping, 16.3 kg (36 lb) Warranty Period: One year More detailed specifications at www.agilent.com/find/6540 40 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 200 W (Continued) Ordering Information Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 240 209 to 250 Vac, 47 to 63 Hz * Opt 908 Rack-mount Kit (p/n 5063-9212) * Opt 909 Rack-mount Kit w/ Handles (p/n 5063-9219) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Accessories p/n 1494-0060 Accessory Slide Kit E3663AC Support rails for Agilent rack cabinets Agilent Models: 6541A, 6542A, 6543A, 6544A, 6545A Top 421.7mm 16.6" + - 240 Vdc Max to + - 425.5mm 16.75" 6 - 32 x 3/8 Screws { A Thomas & Betts 22-18 ring crimp-on will fit in this area } Terminal Screw Size: m4 x 0.7 x 8mm 434.3mm 17.1" 12.7mm 0.5" 88.1mm 3.5" Rear 100mm 3.93" Side Output More detailed specifications at www.agilent.com/find/6540 41 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 500 W GPIB 6651A-6655A Fast, low-noise outputs Analog control of output voltage and current Fan-speed control to minimize acoustic noise Built-in measurements and advanced programmable features Protection features to ensure DUT safety Specifications 6651A 6652A 6653A 6654A 6655A (at 0 to 55 C unless otherwise specified) This series of 500 W linear-regulated DC power supplies is designed to maximize the throughput of DUTs through the manufacturing test process with fast up and down programming time. Valuable assemblies can be destroyed by a minor component failure that causes a surge of current to flow into the DUT. Fast protection features, including fast crowbar, mode crossover protection, and the ability to connect the protection circuitry of multiple power supplies can increase production yield. Programming of the DC output and the protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified be using the VXIPlug&Play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes. Lab bench use is enhanced by the fan speed control, which helps to minimize the acoustic noise. 6651AJ01 Special Order Option Number of outputs 1 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Yes Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V 10 V Output current (40C) 0 to 50 A 0 to 25 A 0 to 15 A 0 to 9 A 0 to 4 A 50 A Maximum current (50C/55C) 45 A/42.5 A 22.5 A/21.3 A 13.5 A/12.8 A 8.1 A/7.7 A 3.6 A/3.4 A 45 A/42.5 A Output ratings Programming accuracy at 25C 5C Voltage 0.06% + 5 mV 10 mV 15 mV 26 mV 51 mV 6 mV Current 0.15% + 60 mA 25 mA 13 mA 8 mA 4 mA 60 mA Voltage rms 300 V 300 V 400 V 500 V 700 V 300 V peak-peak 3 mV 3 mV 4 mV 5 mV 7 mV 3 mV Current rms 25 mA 10 mA 5 mA 3 mA 2 mA 25 mA Ripple and noise from 20 Hz to 20 MHz Readback accuracy at 25C 5C (percent of reading plus fixed) System models only Voltage 0.07% + 6 mV 15 mV 25 mV 40 mV 80 mV 7.5 mV +Current 0.15% + 67 mA 26 mA 15 mA 7 mA 3 mA 67 mA -Current 0.35% + 100 mA 44 mA 24 mA 15 mA 7 mA 100 mA Voltage 1 mV 2 mV 3 mV 4 mV 5 mV 1 mV Current 2 mA 1 mA 0.5 mA 0.5 mA 0.5 mA 2 mA Voltage 0.5 mV 0.5 mV 1 mV 1mV 2 mV 0.5 mV Current 2 mA 1 mA 0.75 mA 0.5 mA 0.5 mA 2 mA Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Load regulation Line regulation Average resolution Voltage 2 mV 5 mV 10 mV 15 mV 30 mV 2.5 mV Current 15 mA 7 mA 4 mA 2.5 mA 1.25 mA 15 mA OVP 12 mV 30 mV 54 mV 93 mV 190 mV 16 mV OVP accuracy 160 mV 400 mV 700 mV 1.2 V 2.4 V 200 mV More detailed specifications at www.agilent.com/find/6650 42 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 500 W GPIB (Continued) Specifications 6651AJ03 6651AJ09 6652AJ03 6653AJ04 6653AJ17 Special Order Option Special Order Option Special Order Option Special Order Option Special Order Option Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes (at 0 to 55 C unless otherwise specified) Application Notes: 10 Practical Tips You Need to Know About Your Power Products 5965-8239E 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E Understanding Linear Power Supply Operation (AN1554) 5989-2291EN Modern Connectivity Using USB and LAN I/O Converters (AN 1475-1) 5989-0123EN Agilent DC Power Supplies for Base Station Testing 5988-2386EN Output ratings Output voltage 6V 17V/20 V 27 V 40 V 30 V Output current (40C) 60 A 30 A/15 A 18.5 A 12.5 A 17.5 A Maximum current (50C/55C) 54 A/5 1A 27 A/25.5 A 13.5 A/12.75 A 16.65 A/15.72 A 11.25 A/10.6 A 15.75 A/14.87 A Programming accuracy at 25C 5C Voltage 0.06% + 5 mV 10 mV 13.5 mV 17.5 mV 15 mV Current 0.15% + 75 mA 36 mA 25 mA 13 mA 16 mA Ripple and noise from 20 Hz to 20 MHz Voltage rms 300 V 300 V 450 V 1.6 mV 400 V peak-peak 3 mV 4 mV 4.5 mV 5 mV 4 mV Current rms 30 mA 13 mA 10 mA 5 mA 6 mA Readback accuracy at 25C 5C (percent of reading plus fixed) System models only Voltage 0.07% + 6 mV 15 mV 20.5 mV 30 mV 25 mV +Current 0.15% + 80 mA 40 mA 26 mA 15 mA 18 mA -Current 0.35% + 150 mA 55 mA 44 mA 24 mA 28 mA Voltage 1 mV 2 mV 2 mV 3.5 mV 3 mV Current 6.5 mA 2 mA 1 mA 1 mA 0.5 mA Load regulation Line regulation Voltage 0.5 mV 0.5 mV 0.5 mV 1 mV 1 mV Current 2 mA 2 mA 2 mA 0.75 mA 0.75 mA Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 2 mV 5 mV 6.75 mV 12mV 10 mV Current 18 mA 9 mA 7 mA 4 mA 5 mA OVP 12 mV 30 mV 30 mV 65 mV 54 mV OVP accuracy 160 mV 500 mV 400 mV 750 mV 700 mV More detailed specifications at www.agilent.com/find/6650 43 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 500 W GPIB (Continued) Specifications 6654AJ04 6654AJ05 6654AJ12 6655AJ05 6655AJ10 Special Order Option Special Order Option Special Order Option Special Order Option Special Order Option Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Output voltage 70 V 50 V 80 V 150 V 156 V DC Floating Voltage: Output terminals can be floated up to 240 Vdc from chassis ground Output current (40C) 7.5 A 10 A 6A 3.2 A 3A Maximum current (50C/55C) 6.75 A/6.37 A 9 A/8.5 A 5.4 A/5.1 A 2.88 A/2.72 A 2.7 A/2.55 A Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the GPIB Voltage 0.06% + 30 mV 26 mV 35 mV 64 mV 71 mV Current 0.15% + 7 mA 9 mA 7 mA 3.5 mA 4 mA (at 0 to 55 C unless otherwise specified) Supplemental Characteristics for all model numbers Output ratings Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms. Programming accuracy at 25C 5C Ripple and noise from 20 Hz to 20 MHz Voltage rms 600 V 500 V 700 V 800 V 900 V peak-peak 6 mV 5 mV 7 mV 8 mV 8 mV Current rms 5 mA 4 mA 3 mA 2 mA 3 mA Readback accuracy at 25C 5C (percent of reading plus fixed) System models only Voltage 0.07% + 50 mV 40 mV 58 mV 100 mV 110 mV +Current 0.15% + 6 mA 8 mA 6 mA 2.5 mA 3 mA -Current 0.35% + 13 mA 17 mA 16 mA 6.5 mA 7.5 mA Load regulation Down Programming: An active down programmer sinks approximately 20% of the rated output current Voltage 4 mV 4 mV 4 mV 6 mV 7 mV Current 0.5 mA 0.5 mA 0.5 mA 0.5 mA 1 mA Modulation: (Analog programming of output voltage and current) Input signal: 0 to -5 V Input impedance: 10 k Ohm nominal Voltage 1 mV 1 mV 4.5 mV 2 mV 2 mV Current 0.5 mA 0.5 mA 0.5 mA 0.5 mA 1 mA Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Line regulation AC Input: (AC input frequency 47 to 63 Hz) Voltage Current 100 Vac 12 A 120 Vac 10 A 220 Vac 5.7 A 240 Vac 5.3 A Input Power: 1,380 VA, 1,100 W at full load; 120 W at no load Average resolution Voltage 17.5 mV 15 mV 20 mV 37.5 mV GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI-compatible command set. Current 1.9 mA 2.75 mA 1.7 mA 8 mA 8 mA OVP 110 mV 93 mV 130 mV 240 mV 250 mV OVP accuracy 1.4 V 1.2 V 1.6 V 3V 3.3 V 39.5 mV Software Driver: *IVI-COM *VXIPlug&Play Regulatory Compliance: Listed to UL 1244; conforms to IEC 61010-1. Size: 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.22 in x 19.6 in) Weight: Net, 25 kg (54 lb); shipping, 28 kg (61 lb) Warranty Period: One year More detailed specifications at www.agilent.com/find/6650 44 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 500 W GPIB (Continued) Accessories Ordering Information p/n 1494-0059 Accessory Slide Kit p/n 1252-3698 7-pin Analog Plug p/n 1252-1488 4-pin Digital Plug p/n 5080-2148 Serial Link Cable 2 m (6.6 ft) E3663AC Support rails for Agilent rack cabinets Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 240 209 to 250 Vac, 47 to 63 Hz * Opt 908 Rack-mount Kit (p/n 5062-3977) * Opt 909 Rack-mount Kit w/ Handles (p/n 5063-9221) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Agilent Models: 6651A, 6652A, 6653A, 6654A, 6655A Top 497.8mm 19.6" Rear Output + - Vdc Max + - IP VP IM IM+P S S + - + - 425.5mm 16.75" Metric Pan Head, M4 x 0.7 x 8 mm long (center to center on these two screws is 20 mm, typ) Terminal Screw Size: 6-32 x 5/16in 518.2mm 20.4" 128mm 5.04" Rear 12.7mm 0.5" 132.6mm 5.2" Side More detailed specifications at www.agilent.com/find/6650 45 145.1mm 5.71" High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 500 W 6551A-6555A Front panel and analog control of output voltage and current Fast, low-noise outputs Fan-speed control to minimize acoustic noise Protection features to ensure DUT safety Specifications 6551A 6552A 6553A 6554A 6555A (at 0 to 55 C unless otherwise specified) This reliable series of 500 W DC power supplies can be controlled either from the front panel or via an analog programming voltage. When used in a test system, the fast up and down programming helps decrease test time. Quickly reacting protection features, including fast crowbar, CV/CC mode crossover and over-voltage protection help protect your valuable assemblies from damage. The linear topology produces very low ripple and noise, which allows you to make extremely accurate measurements of the devices which you are testing. Number of outputs 1 1 1 1 1 GPIB No No No No No Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V Output current (40 C) 0 to 50 A 0 to 25 A 0 to 15 A 0 to 9 A Maximum current (50 C/55 C) 45 A/42.5 A 22.5 A/21.3 A 13.5 A/12.8 A 8.1 A/7.7 A 3.6 A/3.4 A Lab bench use is enhanced by the fan speed control, which helps to minimize the acoustic noise. Output ratings 0 to 4 A Programming accuracy at 25C 5C Voltage 0.06% + 5 mV 10 mV 15 mV 26 mV 51 mV Current 0.15% + 60 mA 25 mA 13 mA 8 mA 4 mA Voltage rms 300 V 300 V 400 V 500 V 700 V peak-peak 3 mV 3 mV 4 mV 5 mV 7 mV Current rms 25 mA 10 mA 5 mA 3 mA 2 mA Voltage 1 mV 2 mV 3 mV 4 mV 5 mV Current 2 mA 1 mA 0.5 mA 0.5 mA 0.5 mA Voltage 0.5 mV 0.5 mV 1 mV 1mV 2 mV Current 2 mA 1 mA 0.75 mA 0.5 mA 0.5 mA Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Ripple and noise from 20 Hz to 20 MHz Load regulation Line regulation Average resolution Voltage 2 mV 5 mV 10 mV 15 mV 30 mV Current 15 mA 7 mA 4 mA 2.5 mA 1.25 mA OVP 12 mV 30 mV 54 mV 93 mV 190 mV OVP accuracy 160 mV 400 mV 700 mV 1.2 V 2.4 V More detailed specifications at www.agilent.com/find/6550 46 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 500 W (Continued) Specifications (at 0 to 55 C unless otherwise specified) Application Notes: 6551A-J01 6551A-J03 6553A-J04 6553A-J17 Special Order Option Special Order Option Special Order Option Special Order Option Number of outputs 1 1 1 1 GPIB No No No No 30 V Output ratings 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Output voltage 10 V 6V 40 V Output current (40 C) 50 A 60 A 12.5 A 17.5 A Maximum current (50 C/55 C) 45 A/42.5 A 54 A/51 A 11.25 A/10.6 A 15.75 A/14.87 A Understanding Linear Power Supply Operation (AN1554) 5989-2291EN Programming accuracy at 25C 5C Agilent DC Power Supplies for Base Station Testing 5988-2386EN Voltage 0.06% + 6 mV 5 mV 17.5 mV 15 mV Current 0.15% + 60 mA 75 mA 13 mA 16 mA Voltage rms 300 V 300 V 1.6 mV 400 V peak-peak 3 mV 3 mV 5 mV 4 mV Current rms 25 mA 30 mA 5 mA 6 mA Voltage 1 mV 1 mV 3.5 mV 3 mV Current 2 mA 6.5 mA 1 mA 0.5 mA Voltage 0.5 mV 0.5 mV 1 mV 1 mV Current 2 mA 2 mA 0.75 mA 0.75 mA Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Ripple and noise from 20 Hz to 20 MHz Load regulation Line regulation Average resolution Voltage 2.5 mV 2 mV 12 mV 10 mV Current 15 mA 18 mA 4 mA 5 mA OVP 16 mV 12 mV 65 mV 54 mV OVP accuracy 200 mV 160 mV 750 mV 700 mV More detailed specifications at www.agilent.com/find/6550 47 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 500 W (Continued) Specifications (at 0 to 55 C unless otherwise specified) Supplemental Characteristics for all model numbers Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less than 15 ms. The output voltage change settles within 1 LSB (0.025% x rated voltage) of final value in less than 60 ms. Down Programming: An active down programmer sinks approximately 20% of the rated output current Modulation: (Analog programming of output voltage and current) Input signal: 0 to -5 V Input impedance: 10 k Ohm nominal AC Input: (AC input frequency 47 to 63 Hz) 100 Vac 120 Vac 12 A 10 A 220 Vac 5.7 A 6554A-J05 6554A-J12 6555A-J10 Special Order Option Special Order Option Special Order Option Special Order Option Number of outputs 1 1 1 1 GPIB No No No No Output voltage 70 V 50 V 80 V 156 V Output current (40 C) 7.5 A 10 A 6A 3A Maximum current (50 C/55 C) 6.75 A/6.37 A 9 A/8.5 A 5.4 A/5.1 A 2.7 A/2.55 A Output ratings DC Floating Voltage: Output terminals can be floated up to 240 Vdc from chassis ground Voltage Current 6554A-J04 240 Vac 5.3 A Input Power: 1,380 VA, 1,100 W at full load; 120 W at no load Regulatory Compliance: Listed to UL 1244; certified to CSA556B; conforms to IEC 61010-1. Programming accuracy at 25C 5C Voltage 0.06% + 38 mV 26 mV 35 mV 71 mV Current 0.15% + 7 mA 9 mA 7 mA 4 mA Voltage rms 600 V 500 V 700 V 900 V peak-peak 6 mV 5 mV 5 mV 8 mV Current rms 5 mA 4 mA 3 mA 3 mA Voltage 4 mV 4 mV 4 mV 7 mV Current 0.5 mA 0.5 mA 0.5 mA 1 mA Voltage 1 mV 1 mV 4.5 mV 2 mV Current 0.5 mA 0.5 mA 0.5 mA 1 mA Transient response time Less than 100 s for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater) following any step change in load current of up to 50% of rated current Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Ripple and noise from 20 Hz to 20 MHz Load regulation Line regulation Average resolution Voltage 17.5 mV 15 mV 20 mV Current 1.9 mA 2.75 mA 1.7 mA 39.5 mV 8 mA OVP 110 mV 93 mV 130 mV 250 mV OVP accuracy 1.4 V 1.2 V 1.6 V 3.3 V Size: 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.22 in x 19.6 in) Weight: Net, 25 kg (54 lb); shipping, 28 kg (61 lb) Warranty Period: One year More detailed specifications at www.agilent.com/find/6550 48 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 500 W (Continued) Ordering Information Accessories p/n 1494-0059 Accessory Slide Kit E3663AC Support rails for Agilent rack cabinets Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 240 209 to 250 Vac, 47 to 63 Hz * Opt 908 Rack-mount Kit (p/n 5062-3977) * Opt 909 Rack-mount Kit w/ Handles (p/n 5063-9221) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Agilent Models: 6551A, 6552A, 6553A, 6554A, 6555A Top 497.8mm 19.6" Rear Output + - Vdc Max + - IP VP IM IM+P S S + - + - 425.5mm 16.75" Metric Pan Head, M4 x 0.7 x 8 mm long (center to center on these two screws is 20 mm, typ) Terminal Screw Size: 6-32 x 5/16in 518.2mm 20.4" 128mm 5.04" Rear 12.7mm 0.5" 132.6mm 5.2" Side More detailed specifications at www.agilent.com/find/6550 49 145.1mm 5.71" High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 2000 W GPIB 6671A - 6675A Fast, low-noise outputs Analog control of output voltage and current Fan-speed control to minimize acoustic noise Built-in measurements and advanced programmable features Protection features to ensure DUT safety Specifications 6671A 6672A 6673A 6674A 6675A Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V Output current 0 to 220 A 0 to 100 A 0 to 60 A 0 to 35 A 0 to 18 A 8 mV 20 mV 35 mV 60 mV 120 mV 125 mA 60 mA 40 mA 25 mA 12 mA (at 0 to 55 C unless otherwise specified) This series of 2000 watt DC power supplies has the exceptional, proven reliability that test system engineers look for. It also has the unusual combination of high efficiency and low noise operation. Programming of the DC output and the extensive protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified be using the VXIPlug&Play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes. Lab-bench use is enhanced by the fan-speed control, which minimizes acoustic noise. The extremely low ripple and noise helps the built-in measurement system make extremely accurate current and voltage measurements. Output ratings Programming accuracy at 25C 5C Voltage 0.04% + Current 0.1% + Ripple and noise from 20 Hz to 20 MHz Voltage rms 650 V 750 V 800 V 1.25 mV 1.9 mV Voltage peak to peak 7 mV 9 mV 9 mV 11 mV 16 mV Current rms 200 mA 100 mA 40 mA 25 mA 12 mA Readback accuracy at 25C 5C (percent of reading plus fixed) Voltage 0.05% + 12 mV 30 mV 50 mV 90 mV 180 mV Current 0.1% + 150 mA 100 mA 60 mA 35 mA 18 mA 0.002%+ 300 V 650 V 1.2 mV 2 mV 4 mV 0.005%+ 10 mA 7 mA 4 mA 2 mA 1 mA Load regulation Voltage Line regulation Current Transient response time Less than 900 s for the output voltage to recover 100 mV following a change in load from 100% to 50% or 50% to 100% of the output current rating of the supply Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 2 mV 5 mV 10 mV 15 mV 30 mV Current 55 mA 25 mA 15 mA 8.75 mA 4.5 mA OVP 15 mV 35 mV 65 mV 100 mV 215 mV 30 ms 60 ms 130 ms 130 ms 195 ms Output Voltage programming response time* (excluding command processing time) * Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output voltage/rated output current. More detailed specifications at www.agilent.com/find/6670 50 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 2000 W GPIB (Continued) Specifications 6671A- 6671A- 6671A- 6671A- 6672A- 6673AJ03 J04 J08 J17 J04 J03 (at 0 to 55 C unless otherwise specified) Application Notes: Special Order Option Special Order Special Order Special Order Special Order Option Option Option Option Special Order Option Number of outputs 1 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Yes Output ratings 6671A/72A/81A/82A/90A System DC Power Supplies Product Overview 5988-3050EN Output voltage 14 V 10 V 3V 15 V 24 V 37.5 V Output current 150 A 200 A 300 A 120 A 85 A 45 A Agilent DC Power Supplies for Base Station Testing 5988-2386EN Voltage 0.04%+ 14 mV 10 mV 4 mV 15 mV 25 mV 37.5 mV Current 0.1%+ 90 mA 125 mA 250 mA 90 mA 60 mA 40 mA 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Programming accuracy at 25C 5C Ripple and noise from 20 Hz to 20 MHz Voltage rms 1.5 mV 750 V 1 mV 1.5 mV 1 mV 800 V Voltage peak to peak 15 mV 9 mV 25 mV 15 mV 11 mV 9 mV Current rms 150 mA 200 mA 275 mA 150 mA 100 mA 40 mA Readback accuracy at 25C 5C (percent of reading plus fixed) System models only Voltage 0.05% + 25 mV 15 mV 6 mV 27 mV 40 mV 53.5 mV Current 0.1% + 110 mA 150 mA 250 mA 110 mA 100 mA 60 mA 0.002%+ 600 V 300 V 300 V 650 V 650 V 1.2 mV 0.005%+ 7 mA 10 mA 15 mA 7 mA 7 mA 4 mA Load regulation Voltage Line regulation Current Transient response time Less than 900 s for the output voltage to recover 100 mV following a change in load from 100% to 50% or 50% to 100% of the output current rating of the supply Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 4 mV 2.5 mV 1 mV 4 mV 6 mV Current 40 mA 55 mA 75 mA 35 mA 22 mA 10 mV 15 mA OVP 28 mV 20 mV 8 mV 30 mV 42 mV 65 mV 30 ms 35 ms 30 ms 35 ms 70 ms 130 ms Output Voltage programming response time* (excluding command programming processing time) * Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output voltage/rated output current. More detailed specifications at www.agilent.com/find/6670 51 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 2000 W GPIB (Continued) Specifications 6673AJ08 6674AJ03 6674AJ07 6675AJ04 6675AJ06 Special Order Option Special Order Option Special Order Option Special Order Option Special Order Option Number of outputs 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes (at 0 to 55 C unless otherwise specified) Supplemental Characteristics for all model numbers Output ratings Output voltage 40 V 56 V 50 V 160 V 135 V DC Floating Voltage: Output terminals can be floated up to 240 Vdc from chassis ground Output current 50 A 38 A 42 A 13 A 16 A Voltage 0.04%+ 40 mV 60 mV 60 mV 160 mV 125 mV Output Common-Mode Noise Current: (to signal ground binding post) 500 A rms, 4 mA peak-to-peak Current 0.1%+ 35 mA 28 mA 30 mA 10 mA 12 mA Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Voltage rms 1 mV 1.25 mV 1.25 mV 2.8 mV 2 mV Voltge peak to peak 10.5 mV 11 mV 11 mV 20 mV 18 mV Current rms 40 mA 28 mA 25 mA 18 mA 12 mA Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the GPIB. Modulation: (Analog programming of output voltage and current) Input Signal: 0 to -4 V for voltage, 0 to 7 V for current Input Impedance: 60 k Ohm or greater Input Power: 3,800 VA, 2,600 W at full load; 170 W at no load GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI-compatible command set Programming accuracy at 25C 5C Ripple and noise from 20 Hz to 20 MHz Readback accuracy at 25C 5C (percent of reading plus fixed) System models only Voltage 0.05%+ 60 mV 90 mV 90 mV 240 mV 185 mV Current 0.1%+ 60 mA 38 mA 42 mA 14 mA 18 mA 0.002%+ 1.4 mV 2 mV 2 mV 6 mV 4 mV 0.005%+ 4 mA 2 mA 2 mA 1 mA 4 mV Load regulation Voltage Line regulation Current Transient response time Less than 900 s for the output voltage to recover 100 mV following a change in load from 100% to 50% or 50% to 100% of the output current rating of the supply Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 10.5 mV 14 mV 12 mV 40 mV Current 12.5 mA 9.5 mA 11 mA 3.25 mA 34 mV 4 mA Software Driver: *IVI-COM *VXIPlug&Play OVP 75 mV 100 mV 85 mV 300 mV 242 mV Regulatory Compliance: Listed to UL1244; certified to CSA556B; conforms to IEC 61010-1. (excluding command programming processing time) 130 ms 130 ms 130 ms 280 ms 250 ms Output Voltage programming response time* * Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output voltage/rated output current. Size: 425.5 mm W x 132.6 mm H x 640 mm D (16.75 in x 5.22 in x 25.2 in) Weight: Net, 28.2 kg (62 lbs); shipping, 31.8 kg (70 lbs) Warranty Period: One year More detailed specifications at www.agilent.com/find/6670 52 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 2000 W GPIB (Continued) Specifications 6675AJ07 6675AJ08 6675AJ09 6675A J11 Special Order Option Special Order Option Special Order Option Special Order Option Number of outputs 1 1 1 1 GPIB Yes Yes Yes Yes Output voltage 200 V 100 V 110 V 150 V Output current 11 A 22 A 20 A 15 A 200 mV 120 mV 120 mV 150 mV 8 mA 15 mA 13.5 mA 11 mA Voltage rms 3.5 mV 1.9 mV 1.9 mV 2.5 mV Voltge peak to peak 25 mV 16 mV 16 mV 18 mV Current rms 15 mA 15 mA 13.5 mA 12 mA (at 0 to 55 C unless otherwise specified) Ordering Information Opt 200 174 to 220 Vac, 47 to 63 Hz (Japan only) Opt 230 191 to 250 Vac, 47 to 63 Hz * Opt 908 Rack-mount Kit (p/n 5062-3977) * Opt 909 Rack-mount Kit w/handles (p/n 5063-9221) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual A line cord option must be specified, see the AC line voltage and cord section. * Support rails required Output ratings Programming accuracy at 25C 5C Voltage 0.04%+ Current 0.1%+ Ripple and noise from 20 Hz to 20 MHz Readback accuracy at 25C 5C (percent of reading plus fixed) System models only Voltage 0.05%+ 300 mV 180 mV 180 mV 225 mV Current 0.1%+ 12 mA 22 mA 20 mA 15 mA 0.002% + 7 mV 4 mV 4 mV 6 mV 0.005% + 1 mA 4 mV 4 mV 1 mA Load regulation Accessories p/n 1494-0059 Accessory Slide Kit p/n 1252-3698 7-pin Analog Plug p/n 1252-1488 4-pin Digital Plug p/n 5080-2148 Serial Link Cable 2 m (6.6 ft) E3663AC Support rails for Agilent rack cabinets Voltage Line regulation Current Transient response time Less than 900 s for the output voltage to recover 100 mV following a change in load from 100% to 50% or 50% to 100% of the output current rating of the supply Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 50 mV 30 mV 30 mV Current 2.75 mA 4.5 mA 4.5 mA 37.5 mV 3.75 mA OVP 360 mV 215 mV 215 mV 270 mV 350 ms 195 ms 195 ms 250 ms Output Voltage programming response time* (excluding command programming processing time) * Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output voltage/rated output current. More detailed specifications at www.agilent.com/find/6670 53 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 2000 W GPIB (Continued) Agilent Models: 6671A, 6672A, 6673A, 6674A, 6675A Top 574mm 22.6" Rear Connector Detail Accepts Wire AWG 12-22 1/4" x 1" untreaded hole on each bussbar Buss Bar Detail 1.25" 0.31 dia" IM VP +IP -LS -IP +P +S -S 425.5mm 16.75" 1.0 " 0.5 " +LS 0.75" 640mm 25.4" Note: Buss Bar is 1/8" thick cu 68mm 2.67" 128mm 5.04" Rear 132.6mm 5.2" Side 12.7mm 0.5" 145.1mm 5.71" More detailed specifications at www.agilent.com/find/6670 54 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 2000 W GPIB E4356A Dual range output Fast, low-noise outputs Analog control of output voltage and current Fan-speed control to minimize acoustic noise Built-in measurements and advanced programmable features Protection features to ensure DUT safety Specifications E4356A (at 0 to 55 C unless otherwise specified) This 2000 W DC power supply provides over 2000 watts at either 70 or 80 volts. This makes it particularly suitable for a variety of test scenarios for 48 volt systems. Telephone network equipment is one example of such a 48 volt bus application. It also has the unusual combination of high efficiency and low noise operation. Number of outputs 1 GPIB Yes Output ratings Voltage 0 to 70 V/0 to 80 V Current 0 to 30 A/0 to 26 A Programming accuracy at 25C 5C (% of setting plus fixed) Voltage 0.04% + 80 mV +Current 0.1% + 25 mA Ripple and noise 20 Hz to 20 MHz Programming of the DC output and the extensive protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified by using the VXIPlug&Play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes. Lab-bench use is enhanced by the fan-speed control, which minimizes acoustic noise. The extremely low ripple and noise helps the built-in measurement system make extremely accurate current and voltage measurements. Voltage rms 2 mV peak-peak 16 mV Current rms 25 mA DC measurement accuracy (via GPIB or front panel meters with respect to actual output at 25C 5C Voltage 0.05% + 120 mV Current 0.1% + 35 mA Transient response time Time for the output voltage to recover to within 20 mV or 0.1% of the voltage rating of the unit following a change in load current of up to 50% of the output current rating. <900 s Supplemental Characteristics for all model numbers Application Notes: Agilent DC Power Supplies for Base Station Testing 5988-2386EN 10 Practical Tips You Need to Know About Your Power Products 5965-8239E 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E DC Floating Voltage: Output terminals can be floated up to 240 Vdc maximum from chassis ground. Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. More detailed specifications at www.agilent.com/find/E4356 55 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 2000 W GPIB (Continued) Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for the power supplies connected directly to the GPIB. (Display disabled.) Regulatory Compliance: Listed to UL1244; certified to CSA556B, conforms to EN61010. Warranty Period: One year Size: 425.5 mm W x 132.6 mm H x 640 mm D See page 102 for more details Output Voltage Rise Time/Fall Time: 100 ms/200 ms for output to change from 90% to 10% or from 10% to 90% of its total excursion with full resistive load (excludes command processing time). Weight: 27.7 kg (61 lbs) net, 31.4 kg (69 lbs) shipping. Modulation: (Analog programming of output voltage and current) Input Signal: 0 to -4 V for voltage and current Input Impedance: 60 k Ohm nominal Ordering Information Opt 200 174 to 220 Vac, 47 to 63 Hz (Japan only) Opt 230 191 to 250 Vac, 47 to 63 Hz * Opt 908 Rack-mount Kit (p/n 5062-3977) * Opt 909 Rack-mount Kit w/Handles (p/n 5063-9221) Input Power: 3800 VA, 2600 W at full load; 100 W at no load GPIB Interface Capabilities: SH1, AH1, TE6, LE4, SR1, RL1, PP0, DC1, DT1, E1 and C0. IEEE-488.2 and SCPI-compatible command set Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual A line cord option must be specified, see the AC line voltage and cord section. * Support rails required Accessories p/n 1494-0059 Accessory Slide Kit p/n 1252-3698 7-pin Analog Plug p/n 1252-1488 4-pin Digitial Plug p/n 5080-2148 Serial Link Cable 2 m (6.6 ft) E3663AC Support rails for Agilent rack cabinets Agilent Models: E4356A Software Driver: *IVI-COM *VXIPlug&Play Top 574mm 22.6" Rear Connector Detail Accepts Wire AWG 12-22 1/4" x 1" untreaded hole on each bussbar Buss Bar Detail 1.25" 0.31 dia" IM VP +IP -LS -IP +P +S -S 425.5mm 16.75" 1.0 " 0.5 " +LS 0.75" 640mm 25.4" Note: Buss Bar is 1/8" thick cu 68mm 2.67" 128mm 5.04" Rear 132.6mm 5.2" Side 12.7mm 0.5" 145.1mm 5.71" More detailed specifications at www.agilent.com/find/E4356 56 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 2000 W 6571A-6575A Front panel and analog control of output voltage and current Fast, low-noise outputs Fan-speed control to minimize acoustic noise Protection features to ensure DUT safety Specifications 6571A 6572A 6573A 6574A 6575A (at 0 to 55 C unless otherwise specified) 6571AJ03 Special Order Option This series of 2000 watt DC power supplies has the exceptional, proven reliability that test system engineers look for. It also has the unusual combination of high efficiency and low noise operation. Number of outputs 1 1 1 1 1 1 GPIB No No No No No No These DC power supplies can be controlled either from the front panel or via an analog programming voltage. When used in a test system, the fast up and down programming helps decrease test time. Quickly reacting protection features, including CV/CC mode crossover and over-voltage protection help protect your valuable assemblies from damage. Voltage 0.04% + Current 0.1% + Lab-bench use is enhanced by the fan-speed control, which minimizes acoustic noise. The extremely low ripple and noise helps the test engineer make extremely accurate current and voltage measurements. Output ratings Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V 14 V Output current 0 to 220 A 0 to 100 A 0 to 60 A 0 to 35 A 0 to 18 A 150 A 8 mV 20 mV 35 mV 60 mV 120 mV 14 mV 125 mA 60 mA 40 mA 25 mA 12 mA 90 mA Voltage rms 650 V 750 V 800 V 1.25 mV 1.9 mV 1.5 mV peak-peak 7 mV 9 mV 9 mV 11 mV 16 mV 15 mV Current rms 200 mA 100 mA 40 mA 25 mA 12 mA 150 mA Programming accuracy at 25C 5C Ripple and noise from 20 Hz to 20 MHz Load regulation and line regulation Voltage 0.002%+ 300 V 650 V 1.2 mV 2 mV 4 mV 600 V Current 0.005%+ 10 mA 7 mA 4 mA 2 mA 1 mA 7 mA Transient response time Less than 900 s for the output voltage to recover 100 mV following a change in load from 100% to 50% or 50% to 100% of the output current rating of the supply Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 2 mV 5 mV 9 mV 15 mV 30 mV 4 mV Current 55 mA 25 mA 15 mA 8.75 mA 4.5 mA 40 mA OVP 15 mV 35 mV 65 mV 100 mV 215 mV 28 mV 30 ms 60 ms 130 ms 130 ms 195 ms 30 ms Output voltage programming response time* *Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output voltage/rated output current. More detailed specifications at www.agilent.com/find/6570 57 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 2000 W (Continued) Specifications (at 0 to 55 C unless otherwise specified) Application Notes: Agilent DC Power Supplies for Base Station Testing 5988-2386EN 10 Practical Tips You Need to Know About Your Power Products 5965-8239E 6571A- 6571A- 6573A- 6573A- 6574A- 6574AJ04 J17 J03 J08 J03 J07 Special Order Special Order Special Order Special Order Special Order Special Order Option Option Option Option Option Option Number of outputs 1 1 1 1 1 1 GPIB No No No No No No Output voltage 10 V 15 V 37.5V 40 V 56 V 50 V Output current 200 A 120 A 45 A 50 A 38 A 42 A Output ratings Programming accuracy at 25C 5C Voltage 0.04% + 10 mV 15 mV 37.5 mV 40 mV 60 mV 60 mV Current 0.1% + 125 mA 90 mA 40 mA 35 mA 28 mA 30 mA Voltage rms 750 V 1.5 mV 800 V 1 mV 1.25 mV 1.25 mV peak-peak 9 mV 15 mV 9 mV 10.5 mV 11 mV 11 mV DC Floating Voltage: Output terminals can be floated up to 240 Vdc from chassis ground Current rms 200 mA 150 mA 40 mA 40 mA 28 mA 25 mA Voltage 0.002%+ 300 uV 650 uV 1.2 mV 1.4 mV 2 mV 2 mV Output Common-Mode Noise Current: (to signal ground binding post) 500 A rms, 4 mA peak-to-peak Current 0.005%+ 10 mA 7 mA 4 mA 4 mA 2 mA 2 mA Supplemental Characteristics for all model numbers Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Modulation: (Analog programming of output voltage and current) Input Signal: 0 to -4 V for voltage, 0 to 7 V for current Input Impedance: 30 k Ohm or greater Input Power: 3,800 VA, 2,600 W at full load; 170 W at no load Ripple and noise from 20 Hz to 20 MHz Load regulation and line regulation Transient response time Less than 900 s for the output voltage to recover 100 mV following a change in load from response time 100% to 50% or 50% to 100% of the output current rating of the supply Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 2.5 mV 4 mV 10 mV 10.5 mV 14 mV Current 55 mA 35 mA 15 mA 12.5 mA 9.5 mA 12 mV 11 mA OVP 20 mV 30 mV 65 mV 75 mV 100 mV 85 mV 35 ms 35 ms 130 ms 130 ms 130 ms 130 ms Output voltage programming response time* *Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output voltage/rated output current. Regulatory Compliance: Listed to UL1244; certified to CSA556B; conforms to IEC 61010-1. Size: 425.5 mm W x 132.6 mm H x 640 mm D (16.75 in x 5.22 in x 25.2 in) Weight: Net, 28.2 kg (62 lb); shipping, 31.8 kg (70 lb) Warranty Period: One year More detailed specifications at www.agilent.com/find/6570 58 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 2000 W (Continued) Specifications 6575A- 6575A- 6575A- 6575A- 6575A- 6575AJ04 J06 J07 J08 J09 J11 (at 0 to 55 C unless otherwise specified) Ordering Information Opt 200 174 to 220 Vac, 47 to 63 Hz (Japan only) Opt 230 191 to 250 Vac, 47 to 63 Hz * Opt 908 Rack-mount Kit (p/n 5062-3977) * Opt 909 Rack-mount Kit w/ Handles (p/n 5063-9221) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual A line cord option must be specified, see the AC line voltage and cord section. * Support rails required Accessories p/n 1494-0059 Accessory Slide Kit E3663AC Support rails for Agilent rack cabinets Special Order Special Order Special Order Special Order Special Order Special Order Option Option Option Option Option Option Number of outputs 1 1 1 1 1 1 GPIB No No No No No No Output voltage 160 V 135 V 200 V 100 V 110 V 150 V Output current 13 A 16 A 11 A 22 A 20 A 15 A Output ratings Programming accuracy at 25C 5C Voltage 0.04% + 160 mV 125 mV 200 mV 120 mV 120 mV 150 mV Current 0.1% + 10 mA 12 mA 8 mA 15 mA 13.5 mA 11 mA Voltage rms 2.8 mV 2 mV 3.5 mV 1.9 mV 1.9 mV 2.5 mV peak-peak 20 mV 18 mV 25 mV 16 mV 16 mV 18 mV Current rms 18 mA 12 mA 15 mA 15 mA 13.5 mA 12 mA Ripple and noise from 20 Hz to 20 MHz Load regulation and line regulation Voltage 0.002%+ 6 mV 4 mV 7 mV 4 mV 4 mV 6 mV Current 0.005%+ 1 mA 4 mV 1 mA 4 mV 4 mV 1 mA Transient response time Less than 900 s for the output voltage to recover 100 mV following a change in load from response time 100% to 50% or 50% to 100% of the output current rating of the supply Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average resolution Voltage 40 mV 34 mV 50 mV 30 mV 30 mV Current 3.25 mA 4 mA 2.75 mA 4.5 mA 4.5 mA 37.5 mV 3.75 mA OVP 300 mV 242 mV 360 mV 215 mV 215 mV 270 mV 280 ms 250 ms 350 ms 195 ms 195 ms 250 ms Output voltage programming response time* *Full load programming rise/fall time (10% to 90% or 90%to 10%) with full resistive load equal to rated output voltage/rated output current. More detailed specifications at www.agilent.com/find/6570 59 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 2000 W (Continued) Agilent Models: 6571A, 6572A, 6573A, 6574A, 6575A Top 574mm 22.6" Rear Connector Detail Accepts Wire AWG 12-22 1/4" x 1" untreaded hole on each bussbar Buss Bar Detail 1.25" 0.31 dia" IM VP +IP -LS -IP +P +S -S 425.5mm 16.75" 1.0 " 0.5 " +LS 0.75" 640mm 25.4" Note: Buss Bar is 1/8" thick cu 68mm 2.67" 128mm 5.04" Rear 132.6mm 5.2" Side 12.7mm 0.5" 145.1mm 5.71" More detailed specifications at www.agilent.com/find/6570 60 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 5000 W GPIB Low output ripple and noise Selectable compensation for inductive loads Analog control of output voltage and current Fan-speed control to minimize acoustic noise Built-in measurements and advanced programmable features 6680A-6684A Protection features to ensure DUT safety Specifications 6680A 6681A 6682A 6683A 6684A (at 0 to 55 C unless otherwise specified) Reliable DC power for manufacturing test and long-term burn-in This series of 5000 watt DC power supplies has the exceptional, proven reliability that test system engineers look for. It also has the features needed for easy test system integration. Programming of the DC output and the extensive protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified by using the VXIPlug&Play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes. The 6680A Series has extremely low ripple and noise for a 5000 watt DC power supply. This helps the built-in measurement system make extremely accurate current and voltage measurements. Selectable compensation is provided for problem-free powering of inductive loads. 6680AJ04 Special Order Option Number of outputs 1 1 1 1 1 1 GPIB Yes Yes Yes Yes Yes Yes Voltage 0 to 5 V 0 to 8 V 0 to 21 V 0 to 32 V 0 to 40 V Current (40C then derate linearly 1%/C from 40C to 55C) 0 to 875 A 0 to 580 A 0 to 240 A 0 to 160 A 0 to 128 A 0 to 1000 A 5 mV 8 mV 21 mV 32 mV 40 mV 5 mV 450 mA 300 mA 125 mA 85 mA 65 mA 450 mV rms 1.5 mV 1.5 mV 1.5 mV 1.0 mV 1.0 mV 3.4 mV Peak to peak 10 mV 10 mV 10 mV 10 mV 10 mV 15 mV Output ratings 0 to 3.3 V Programming accuracy at 25C 5C Voltage 0.04% + Current 0.1% + Ripple and noise constant voltage mode from 20 Hz to 20 MHz Readback accuracy at 25C 5C (percent of reading plus fixed) Voltage 0.05% + 7.5 mV 12 mV 32 mV 48 mV 60 mV 7.5 mV Current 0.1% + 600 mA 400 mA 165 mA 110 mA 90 mA 600 mA Voltage 0.002% + 0.19 mV 0.3 mV 0.65 mV 1.1 mV 1.5 mV 0.19 mV Current 0.005% + 65 mA 40 mA 17 mA 12 mA 9 mA 77 mA Load and line regulation Transient response time Less than 900 s for the output voltage to recover within 150 mV following a change in load from 100% to 50%, or 50% to 100% of the output current rating of the supply Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying this product) Ripple and noise constant current mode from 20 Hz to 20 MHz rms 290 mA 190 mA 40 mA 28 mA 23 mA -- Average programming resolution Voltage 1.35 mV 2.15 mV 5.7 mV 8.6 mV 10.8 mV 12 mV Current 235 mA 155 mA 64 mA 43 mA 34 mA 260 mA OVP 30 mV 45 mV 120 mV 180 mV 225 mV 25 mV Output voltage programming response time 9 ms 12 ms 45 ms 60 ms 60 ms 9 ms (excludes command-processing time) Full-load progrmming rise or fall time (10 to 90% or 90 to 10%, resistive load) Output common-mode noise current rms (to signal-ground peak-to-peak binding post) 1.5 mA 10 mA 1.5 mA 10 mA 3 mA 20 mA 3 mA 20 mA 3 mA 20 mA 2.0 mA 12.5 mA Note 1: Option 6680A-JO4 is not available outside the USA because certification process is not complete. More detailed specifications at www.agilent.com/find/6680 61 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 5000 W GPIB (Continued) Application Notes: 6671A/72A/81A/82A/90A System DC Power Supplies Product Overview 5988-3050EN Agilent DC Power Supplies for Base Station Testing 5988-2386EN 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Supplemental Characteristics for all model numbers DC Floating Voltage: Output terminals can be floated up to 60 Vdc maximum from chassis ground Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available for the load. Software Driver: *IVI-COM *VXIPlug&Play Size: 425.5 mm W x 221.5 mm H x 674.7 mm D (16.75 in x 8.75 in x 25.56 in) Weight: Net, 51.3 kg (113 lbs); shipping, 63.6 kg (140 lbs) Warranty Period: One year Ordering Information Opt 208 180 to 235 Vac, 3 phase, 47 to 63 Hz Opt 400 360 to 440 Vac, 3 phase, 47 to 63 Hz Opt 602 Two Bus Bar Spacers for paralleling power supplies (p/n 5060-3514) * Opt 908 Rack-mount Kit (p/n 5062-3977 and p/n 5062-3974) AC Input (47 to 63 Hz): 180 to 235 Vac (line-to-line, 3 phase), 27.7 A rms maximum worst case, 21.4 A rms nominal; 360 to 440 Vac, 14.3 A rms maximum worst case, 10.7 A rms nominal (maximum line current includes 5% unbalanced phase voltage condition.) Output voltage derated 5% at 50 Hz and below 200 Vac. Input Power: 7350 VA and 6000 W maximum; 160 W at no load Accessories p/n 5060-3513 Three 30-A Replacement Fuses for 180 to 235 Vac line p/n 5060-3512 Three 16-A Replacement Fuses for 360 to 440 Vac line E3663AC Support rails for Agilent rack cabinets p/n 5080-2148 Serial link cable 2m (6.6 ft.) Agilent Models: 6680A, 6681A, 6682A, 6683A, 6684A Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for power supplies connected directly to the GPIB Modulation: (analog programming of output voltage and current): Input Signal: 0 to -5 V for voltage, 0 to +5 V for current Input Impedance: 30 k/or greater * Opt 909 Rack-mount Kit with Handles (p/n 5063-9221 and p/n 5063-9219). Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Top 12.7mm 0.5" 425.5mm 16.75" Buss Bar Detail 3/8" Diameter (6) - + 674.7mm 26.56" 3 3/4" 28.6mm 1.13" 667.3mm 26.27" 574mm 22.6" 30.2mm 1.19" 65.1mm 2.56" 221.5mm 8.75" 27.8mm 1.09" 9.5mm 0.38" Rear Output Buss Bars Side 12.7mm 0.5" GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1, and C0. IEEE-488.2 and SCPI command set. More detailed specifications at www.agilent.com/find/6680 62 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output 6600 W GPIB Low output ripple and noise Analog control of output voltage and current Fan-speed control to minimize acoustic noise Built-in measurements and advanced programmable features 6690A-6692A Protection features to ensure DUT safety Specifications 6690A 6691A 6692A Number of outputs 1 1 1 GPIB Yes Yes Yes (at 0 to 55 C unless otherwise specified) Reliable DC power for manufacturing test and long-term burn-in This series of 6600 watt DC power supplies has the exceptional, proven reliability that test system engineers look for. It also has the features needed for easy test system integration. Programming of the DC output and the extensive protection features can be done either from the front panel or using industry standard SCPI commands, via the GPIB. Using the serial link, up to 16 power supplies can be connected through one GPIB address. Test system integration can be further simplified by using the VXIPlug&Play drivers. The output voltage and current can also be controlled with analog signals. This is helpful for certain types of noisy environments, and also immediate reactions to process changes. The 6690A Series has extremely low ripple and noise for a 6600 watt DC power supply. This helps the built-in measurement system make extremely accurate current and voltage measurements. Output ratings Voltage 0 to 15 V 0 to 30 V 0 to 60 V Current (derated linearly 1%/C from 40C to 55C) 0 to 440 A 0 to 220 A 0 to 110 A Programming accuracy at 25C 5C Voltage 0.04% + 15 mV 30 mV 60 mV Current 0.1% + 230 mA 125 mA 65 mA rms 2.5 mV 2.5 mV 2.5 mV Peak to peak 15 mV 25 mV 25 mV Ripple and noise constant voltge mode from 20 Hz to 20 MHz Readback accuracy at 25C 5C (percent of reading plus fixed offset) System models only Voltage 0.05% + 22.5 mV 45 mV 90 mV Current 0.1% + 300 mA 165 mA 80 mA Load regulation Voltage 0.002% + 0.65 mV 1.1 mV 2.2 mV Current 0.005% + 40 mA 17 mA 9 mA Line regulation Voltage 0.002% + 0.65 mV 0.65 mV 0.65 mV Current 0.005% + 40.5 mA 17 mA 9 mA Transient response time Less than 900 s for the output voltage to recover within 150 mV following a change in load from 100% to 50%, or 50% to 100% of the output current rating of the supply Application Notes: 6671A/72A/81A/82A/90A System DC Power Supplies Product Overview 5988-3050EN Using Agilent 6690A Series System DC Power Supplies for Testing Data Storage Control Boards (PN 6690A-1) 5988-3062EN Using Agilent 6690A Series System DC Power Supplies for Automobile Battery Simulation (PN 6690A-2) 5988-3061EN More detailed specifications at www.agilent.com/find/6690 63 High Performance DC Power Supplies speed and accuracy for test optimization Single-Output: 6600 W GPIB (Continued) Specifications 6690A 6691A 6692A (at 0 to 55 C unless otherwise specified) Supplemental Characteristics Supplemental Characteristics for all model numbers DC Floating Voltage: Output terminal can be floated up to 60 Vdc from chassis ground Remote Sensing: Up to half the rated output voltage can be dropped in each load lead. The drop in the load leads subtracts from the voltage available at the load. Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 20 ms for power supplies connected directly to the GPIB. Modulation: (analog programming of output voltage and current): Input Signal: 0 to -5 V for voltage, and 0 to +5 V for current. Input Impedance: 30 k or greater. AC Input (47 to 63 Hz): 180 to 235 Vac (line-to-line 3 phase) 36 A rms maximum worst case, 28 A rms nominal; 360 to 440 Vac, 18 A rms maximum worst case, 14 A rms nominal. (Maximum line current includes 5% unbalanced phase voltage condition). (Non-warranted characteristics determined by design that are useful in applying this product) Ripple and noise constant current mode from 20 Hz to 20 MHz rms 200 mA 50 mA 30 mA Voltage 4.1 mV 8.1 mV 16 mV Current 118.5 mA 59 mA 30 mA OVP 90 mV 170 mV 330 mV 45 ms 60 ms 100 ms 3 mA 20 mA 3.5 mA 20 mA 4 mA 25 mA Average programming resolution Output voltage programming response time (excludes command-processing time) Full-load progrmming rise or fall time (10 to 90% or 90 to 10%, resistive load) Output common-mode noise current rms (to signal-ground peak-to-peak binding post) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Accessories p/n 5065-6935 Replacement fuse kit for 360-440 Vac line. p/n 5065-6934 Replacement fuse kit for 180-235 Vac line. E3663AC Support rails for Agilent rack cabinets. p/n 5080-2148 Serial link cable 2m (6.6 ft.) Agilent Models: 6690A, 6691A, 6692A Software Driver: *IVI-COM *VXIPlug&Play Top 12.7mm 0.5" Input Power: 9000 VA and 7950 W maximum; 175 W at no load. Size: 425.5 mm W x 221.5 mm H x 674.7 mm D (16.75 in x 8.75 in x 25.56 in). 425.5mm 16.75" Buss Bar Detail 3/8" Diameter (6) Warranty Period: One year - + Ordering Information Opt 208 180 to 235 Vac, 3 phase, 47 to 63 Hz Opt 400 360 to 440 Vac, 3 phase, 47 to 63 Hz Opt 602 Two Bus Bar Spacers for paralleling power supplies (p/n 5060-3514) * Opt 908 Rack-mount Kit (p/n 5062-3977 and p/n 5063-9212) * Opt 909 Rack-mount Kit with Handles (p/n 5063-9221 and p/n 5063-9219). 674.7mm 26.56" 3 3/4" 28.6mm 1.13" 667.3mm 26.27" 574mm 22.6" 30.2mm 1.19" 65.1mm 2.56" 221.5mm 8.75" 27.8mm 1.09" 9.5mm 0.38" Rear Output Buss Bars Side 12.7mm 0.5" More detailed specifications at www.agilent.com/find/6690 64 High Performance DC Power Supplies speed and accuracy for test optimization Multiple-Output 40 W-105 W GPIB 6621A-6624A, 6627A Up to four fully isolated power supplies in a 3 U package Dual-range outputs Fast, low-noise outputs Built-in measurements and advanced programmable features Protection features to ensure DUT safety Specifications 40 W output 40 W output 80 W 80 W output output 105 W output Low-range volts, amps 0 to 7 V, 0 to 5 A 0 to 20 V, 0 to 2 A 0 to 7 V, 0 to 10 A 0 to 20 V, 0 to 4 A 0-35 V, 0-3 A High range volts, amps 0 to 20 V, 0 to 2 A 0 to 50 V, 0 to 0.8 A 0 to 20 V, 0 to 4 A 0 to 50 V, 0 to 2 A -- -- 6621A (2) -- -- 2 -- -- 6622A (2) -- -- -- 2 -- 6623A (3) 1 1 1 -- -- 6624A (4) 2 2 -- -- -- 6627A (4) -- 4 -- -- -- 6623A-J03 (3) Special Order Option -- 2 -- -- 1 Voltage 19 mV + 0.06% 50 mV + 0.06% 19 mV + 0.06% 50 mV + 0.06% 35 mV + 0.06% Current 50 mA + 0.16% 20 mA + 0.16% 100 mA + 0.16% 40 mA + 0.16% 30 mA + 0.16% Voltage 20 mV + 0.05% 50 mV + 0.05% 20 mV + 0.05% 50 mV + 0.05% 35 mV + 0.05% +Current 10 mA + 0.1% 4 mA + 0.1% 20 mA + 0.1% 8 mA + 0.1% 6 mA + 0.1% -Current 25 mA + 0.2% 8 mA + 0.2% 50 mA + 0.2% 20 mA + 0.2% 15 mA + 0.2% 500 V 500 V 500 V 500 V 500 V 3 mV 3 mV 3 mV 3 mV 3 mV (at 0 to 55 C unless otherwise specified) Two, three, or four isolated outputs are integrated into one package, conserving rack space and GPIB addresses. Most of the outputs also provide dual ranges, for more current at lower voltage levels. The outputs can be connected in parallel or series to further increase the flexibility that these products offer the system designer. Programming is done using industry standard SCPI commands. Test system integration can be further simplified be using the VXIPlug&Play drivers. These power supplies help reduce test time with fast up and down programming, which is enhanced by an active downprogrammer which can sink the full rated current. Application Notes: Output power Output combinations for each model (total number of outputs) Programming accuracy Readback accuracy (at 25C 5C) Ripple and noise (peak-to-peak, 20 Hz to 20 MHz; rms, 20 Hz to 10 MHz) 10 Practical Tips You Need to Know About Your Power Products 5965-8239E 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E Understanding Linear Power Supply Operation (AN1554) 5989-2291EN Modern Connectivity Using USB and LAN I/O Converters (AN 1475-1) 5989-0123EN Constant voltage rms peak-to-peak Constant current rms 1 mA 1 mA 1 mA 1 mA 1 mA Load regulation Voltage 2 mV 2 mV 2 mV 2 mV 2 mV Current 1 mA 0.5 mA 2 mA 1 mA 2 mA Load cross regulation Voltage 1 mV 2.5 mV 1 mV 2.5 mV N/A Current 1 mA 0.5 mA 2 mA 1 mA N/A Line regulation Voltage 0.01% + 1 mV 0.01% + 1 mV 0.01% + 1 mV 0.01% + 1 mV 0.01% + 1 mV Current 0.06% + 1 mA 0.06% + 1 mA 0.06% + 1 mA 0.06% + 1 mA 0.06% + 1 mA Transient response time Less than 75 s for the output to recover to within 75 mV of nominal value following a load change within specfications More detailed specifications at www.agilent.com/find/6620 65 High Performance DC Power Supplies speed and accuracy for test optimization Multiple-Output: 40 W-105 W GPIB (Continued) Specifications 40 W output (at 0 to 55 C unless otherwise specified) Supplemental Characteristics Supplemental Characteristics for all model numbers DC Floating Voltage: All outputs can be floated up to 240 Vdc from chassis ground Remote Sensing: Up to 1 V drop per load lead. The drop in the load leads is subtracted from the voltage available for the load. Command Processing Time: 7 ms typical with front-panel display disabled Down Programming: Current sink limits are fixed approximately 10% higher than source limits for a given operating voltage above 2.5 V Input Power: 550 W max., 720 VA max. 40 W output 80 W 80 W output output 105 W output (Non-warranted characteristics determined by design and useful in applying the product) Average programming resolution Voltage 6 mV 15 mV 6 mV 6 mV 10.5 mV 20 mV (high) 20 mV (high) Current 25 mA 10 mA 50 mA 50 mA 15 mA 20 mA (high) 20 mA (high) OVP 100 mV 250 mV 100 mV 2 50 mV 175 mV Output programming response time (time to settle within 0.1% of full scale output, after Vset command has been processed) 2 ms 6 ms 2 ms 6 ms 6 ms Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Accessories p/n 1494-0059 Rack Slide Kit E3663A Support rails for Agilent rack cabinets GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP1, DC1, DT0. Software Driver: VXIPlug&Play Regulatory Compliance: Listed to UL1244; conforms to IEC 61010-1; carries the CE mark. Size: 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.22 in x 19.6 in) Weight: Net, 17.4 kg (38 lb); shipping, 22.7 kg (50 lb) Agilent Models: 6621A, 6622A, 6623A, 6624A, 6627A Top 497.8mm 19.6" Terminal Strip Detail Terminal Strip Detail Output 2 & 3 Output 2 &-V3 +V +S -OV +OV -S -OV +OV -S -V +V +S Screw Size: ScrewM35 Size:x 0.6 M35 x 0.6 Warranty Period: One year 425.5mm 16.75" Ordering Information Opt 100 87 to 106 Vac, 47 to 66 Hz Input, 6.3 A (Japan only) Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 66 Hz, 3.0 A Opt 240 209 to 250 Vac, 47 to 66 Hz, 3.0 A Opt 750 Relay Control and DFI/RI Opt S50 similar to option 750, however the remote inhibit does not latch * Opt 908 Rack-mount Kit (p/n 5062-3977) * Opt 909 Rack-mount Kit w/Handles (p/n 5063-9221) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Output Output 1 &14& 4 +S +V -V +S +OV -OV +S +V -V +S +OV -OV Output 2 518.2mm 20.4" Output 4 132.6mm 5.2" 128mm 5.04" Output 3 Output 1 12.7mm 0.5" Rear Side More detailed specifications at www.agilent.com/find/6620 66 High Performance DC Power Supplies speed and accuracy for test optimization Precision Multiple-Output 25 W-50 W GPIB 6625A, 6626A, 6628A, 6629A Up to four fully isolated power supplies in a 3 U package Fast, low-noise outputs Dual-range, precision low current measurement Built-in measurements and advanced programmable features Protection features to ensure DUT safety Specifications 25 W output 50 W output (at 0 to 55 C unless otherwise specified) Two or four isolated outputs are integrated into one package, conserving rack space and GPIB addresses. Dual ranges allow for more current at lower voltage levels. The outputs can be connected in parallel or series to further increase the flexibility that these products offer the system designer. Programming is done using industry standard SCPI commands and test system integration can be further simplified be using the VXIPlug&Play drivers. These power supplies help reduce test time with fast up and down programming, which is enhanced by the active down-programmer which can sink the full rated current. These power supplies are very useful on the R&D bench. The accuracy of both the programming and the measurement systems allow precise control and monitoring of prototype bias power. The extensive protection features protect valuable prototypes, including very fast CV/CC crossover. The power supply can be controlled from either the front panel keypad or, for automated testing, from the GPIB. Output power Output combinations for each model (total number of outputs) Programming accuracy (at 25C 5C) Readback accuracy (at 25C 5C) Ripple and noise Low-range volts, amps 0 to 7 V, 0 to 15 mA 0 to 16 V, 0 to 200 mA High range volts, amps 0 to 50 V, 0 to 500 mA 0 to 50 V, 0 to 1 A or 0 to 16 V, 0 to 2 A 6625A (2) Precision 1 1 6626A (4) Precision 2 2 6628A (2) Precision -- 2 6629A (4) Precision -- 4 Voltage 1.5 mV + 0.016% (low) 10 mV + 0.016% (high) 3 mV + 0.016% (low) 10 mV + 0.016% (high) Current 15 A + 0.04% (low) 100 A + 0.04% (high) 185 A + 0.04% (low) 500 A + 0.04% (high) Voltage 0.016% + 2 mV (low) 0.016% + 10 mV (high) 0.016% + 3.5 mV (low) 0.016% + 10 mV (high) +/-Current 0.03% + 15 A (low) 0.03% + 130 A (high) 0.04% + 250 A (low) 0.04% + 550 A (high) 500 V 500 V 3 mV 3 mV Constant voltage rms (peak-to-peak, 20 Hz to 20 MHz; rms, 20 Hz to 10 MHz) peak-to-peak Constant current rms 0.1 mA 0.1 mA Load regulation Voltage 0.5 mV 0.5 mV Current 0.005 mA 0.01 mA Load cross regulation Voltage 0.25 mV 0.25 mV Current 0.005 mA 0.01 mA Line regulation Voltage 0.5 mV 0.5 mV Current 0.005 mA 0.01 mA Transient response time change within specfications Less than 75 s for the output to recover to within 75 mV of nominal value following a load Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) Average programming resolution Voltage Current OVP Output programming response time 25-watt output 50-watt output 460 V (low) 1 mV (low) 3.2 mV (high) 3.2 mV (high) 1 A (low) 13 A (low) 33 A (high) 131 A (high) 230 mV 230 mV 6 ms 6 ms (time to settle within 0.1% of full scale output, after Vset command has been processed) More detailed specifications at www.agilent.com/find/6620 67 High Performance DC Power Supplies speed and accuracy for test optimization Precision Multiple-Output: 25 W-50 W GPIB (Continued) Application Notes: Ordering Information 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Opt 100 87 to 106 Vac, 47 to 66 Hz Input, 6.3 A (Japan only) Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 66 Hz, 3.0 A Opt 240 209 to 250 Vac, 47 to 66 Hz, 3.0 A Opt 750 Relay Control and DFI/RI Opt S50 Similar to option 750, however the remote inhibit does not latch * Opt 908 Rack-mount Kit (p/n 5062-3977) * Opt 909 Rack-mount Kit w/Handles (p/n 5063-9221) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E Understanding Linear Power Supply Operation (AN1554) 5989-2291EN Modern Connectivity Using USB and LAN I/O Converters (AN 1475-1) 5989-0123EN Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Accessories p/n 1494-0059 Rack Slide Kit E3663AC Support rails for Agilent rack cabinets Supplemental Characteristics for all model numbers DC Floating Voltage: All outputs can be floated up to 240 Vdc from chassis ground Agilent Models: 6625A, 6626A, 6628A, 6629A Top Remote Sensing: Up to 10 V drop per load lead. The drop in the load leads is subtracted from the voltage available for the load. Terminal Strip Detail Command Processing Time: 7 ms typical with front-panel display disabled -OV +OV -S -V +V +S Terminal Strip Detail Output 2 & 3 Output 2 &-V3 +V +S -OV +OV -S Software Driver: VXIPlug&Play Screw Size: ScrewM35 Size:x 0.6 M35 x 0.6 Input Power: 550 W max., 720 VA max. GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP1, DC1, DT0, C0, E1. 497.8mm 19.6" 425.5mm 16.75" Output Output 1 &14& 4 +S +V -V +S +OV -OV +S +V -V +S +OV -OV Regulatory Compliance: Listed to UL 1244; conforms to IEC 61010-1. Size: 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.22 in x 19.6 in) Output 2 Output 4 Weight: 6626A, 6629A: Net, 17.4 kg (38 lb); shipping, 22.7 kg (50 lb) 6625A, 6628A: Net, 15.5 kg (34 lb); shipping, 20.8 kg (46 lb) Warranty Period: One year 518.2mm 20.4" 132.6mm 5.2" 128mm 5.04" Output 3 Output 1 12.7mm 0.5" Rear Side More detailed specifications at www.agilent.com/find/6620 68 High Performance DC Power Supplies speed and accuracy for test optimization Low-Profile Modular Power System 50-300 W GPIB, LAN, USB, LXI Class C Small size: up to 4 outputs in 1 U of rack space 20 DC power modules: basic, performance and precision models Fast output programming with active downprogramming Ultra fast command processing time 3 N6700B, N6701A, N6702A, N6710B-N6712A, N6731-36B, N6741B-46B, N6751A-52A, N6761A-62A, N6773A-N6776A Output sequencing and advanced triggering system Optional LIST mode, built-in digitizer and disconnect relays LXI class C compliant Specifications N6751A N6752A N6761A N6762A (at 0 to 55 C, and derated above 40 C) The Agilent N6700 Low-Profile Modular Power System (MPS) is a switching regulated, multipleoutput programmable DC power supply system with the performance of a linear power supply. The N6700 is a flexible modular platform that allows you to mix and match 20 different DC power modules to create a 1- to 4-channel DC power system to optimized performance, power and price to match test needs. Test system engineers can invest in highperformance outputs where speed and accuracy are needed, or purchase basic performance outputs for simple DC power requirements. Output Ratings Small Size Current high range The Agilent N6700 MPS uses an advanced switching power supply design that fits within 1U of rack space. It has side air vents (no top or bottom air vents) so other instruments can be mounted directly above or below it. (Requires rack mount kit) Voltage 50 V 50 V 50 V 50 V Current 5A 10 A 1.5 A 3A Power 50 W 100 W 50 W 100 W Voltage high range 0.06% + 19 mV 0.006% + 19 mV 0.016% + 6 mV 0.016% + 6 mV Voltage low range ( 5.5 V) N/A N/A 0.016% + 1.5 mV 0.016% + 1.5 mV Current high range 0.1% + 20 mA 0.1% + 20 mA 0.04% + 200 A 0.04% + 200 A 100 mA, @ 0 - 7 V N/A N/A 100 mA, @ 0 - 50 V N/A N/A 0.04% + 15 A 0.04% + 55 A 0.04% + 15 A 0.04% + 55 A 0.05% + 20 mV 0.05% + 20 mV 0.016% + 6 mV 0.016% + 6 mV N/A N/A 0.016% + 1.5 mV 0.016% + 1.5 mV 0.1% + 4 mA 0.1% + 4 mA 0.04% + 160 A 0.04% + 160 A 100 mA, @ 0 - 7 V 1 N/A N/A 100 mA, @ 0 - 50 V N/A N/A 0.03% + 15 A 0.03% + 55 A 0.03% + 15 A 0.03% + 55 A 4.5 mV 350 V 4.5 mV 350 V 4.5 mV 350 V 4.5 mV 350 V Programming Accuracy (at 23C 5C) Current low range Readback Accuracy (at 23C 5C) Voltage high range 5.5 V Voltage low range Current low range Output Ripple and Noise (PARD) (from 20 Hz to 20 MHz) CV peak-to-peak CV rms Load Regulation Protection Features Voltage 2 mV 2 mV 0.5 mV 0.5 mV Each N6700 module is protected against over-voltage, over-current, and over-temperature. A fault condition in one module can be detected within 10 microseconds by other modules so that they can be quickly shut down to avoid hazardous conditions on your DUT. Current 2 mA 2 mA 65 A 65 A Voltage 1 mV 1 mV 0.5 mV 0.5 mV Current 1 mA 1 mA 30 A 30 A Line Regulation 1 Applies when measuring 4006 data points (SENSe:SWEep:POINts = 4096). More detailed specifications at www.agilent.com/find/N6700 69 High Performance DC Power Supplies speed and accuracy for test optimization Low-Profile Modular Power System 50-300 W GPIB (Continued) Specifications N6751A N6752A N6761A N6762A (at 0 to 55 C, and derated above 40 C) Transient Response Time (time to recover to within the settling band following a load change) from 60% to 100% and from 100% to 60% of full load for models N6751A & N6761A Connectivity from 50% to 100% and from 100% to 50% of full load for models N6752A & N6762A The N6700 offers many system oriented features to simplify and accelerate test system development. They support the industry standard SCPI commands and come standard with software drivers. Voltage settling band 75 mV 75 mV 75 mV 75 mV Time < 100 s < 100 s < 100 s < 100 s The N6700 MPS comes standard with GPIB, USB 2.0, and 10/100 Base-T Ethernet LAN interfaces. While GPIB is best suited for use with existing systems, Agilent offers USB and LAN to allow you to take advantage of the availability, speed, and ease-of-use of common computer industry standard interfaces. The N6700 is designed to comply with the LXI class C specification. The N6700 contains a Web server that provides Web pages for monitor, control and setup of the MPS. Output Sequencing Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying the product) Programming Resolution Voltage high range 3.5 mV 3.5 mV 880 V 880 V Voltage low range ( 5.5 V) N/A N/A 90 V 90 V Current high range 3.25 mA 3.25 mA 60 A 60 A Current low range ( 0.1 A) N/A N/A 2 A 2 A 2 mA 2 mA 2 mA 2 mA Accuracy 0.25% + 250 mV 0.25% + 250 mV 0.25% + 250 mV 0.25% + 250 mV Response Time 50 s from ocurence of OV condition to start of output shutdown Output Ripple and Noise (PARD) CC rms Over-voltage Protection Down-programming Capability Continuous power 7W 7W 7W 7W Peak current 7A 7A 3.8 A 3.8 A Modules can discharge a 1000 F capacitor from 50 V to 0 V at a rate of 4 times/second. Maximum Up-programming Time with full resistive load: (time from 10% to 90% of total voltage excursion) Each DC power module can be individually set to turn on or to turn off with a delay. By adjusting the delay times and then commanding the N6700 to turn on/off, you can set the N6700 modules to sequence on/off in a particular order. Voltage setting from 0 V to 10 V 0.2 ms 0.2 ms 0.6 ms 0.6 ms Voltage setting from 0 V to 50 V 1.5 ms 1.5 ms 2.2 ms 2.2 ms Voltage setting from 0 V to 10 V 0.5 ms 0.5 ms 0.9 ms 0.9 ms Voltage setting from 0 V to 50 V 4.0 ms 4.0 ms 4.0 ms 4.0 ms Programmable Voltage Slew Voltage setting from 10 V to 0 V 0.3 ms 0.3 ms 0.3 ms 0.3 ms For some applications, like inrush limiting or powering rate-sensitive devices, it is necessary to slow down and control the speed of the power supply to maintain a specific voltage slew rate. The N6700 provides programmable voltage slew rate, so that with a single command, you can generate a zero to full-scale voltage change controllable from 1 millisecond to 10 seconds. Voltage setting from 50 V to 0 V 1.3 ms 1.3 ms 1.3 ms 1.3 ms Voltage setting from 10 V to 0 V 0.45 ms 0.45 ms 0.45 ms 0.45 ms Voltage setting from 50 V to 0 V 1.4 ms 1.4 ms 1.4 ms 1.4 ms Voltage setting from 10 V to 0 V 2.1 ms 2.1 ms 4.5 ms 4.5 ms Voltage setting from 50 V to 0 V 11 ms 11 ms 23 ms 23 ms Down-programming Capability: Continuous power 7W 7W 7W 7W Peak current 7A 7A 3.8 A 3.8 A Maximum Up-programming Settling Time with full resistive load: (time from start of voltage change to within 50 mV of final value) Maximum Down-programming Time with no load: (time from start of voltage change to output voltage <0.5 V) Maximum Down-programming Settling Time with no load: (time from start of voltage change to within 50 mV of final value) Down-programming with 1000 F load:1 (time from start of voltage change to output voltge <0.5 V) 1 Modules can discharge a 1000 F capacitor from 50 V to 0 V at a rate of 4 times/second More detailed specifications at www.agilent.com/find/N6700 70 High Performance DC Power Supplies speed and accuracy for test optimization Low-Profile Modular Power System 50-300 W GPIB (Continued) Specifications N6773A N6774A N6775A N6776A (at 0 to 55 C, and derated above 40 C) Output Ratings Power Management Feature Allows You Allocate Mainframe Power To further optimize your investment you may choose to save money configuring a system where the sum of the power modules installed in a mainframe exceeds the total power available from the mainframe. In this case, the new power management features of the N6700 allow you to allocate mainframe power to the outputs where it's needed and reduce power to the outputs where it is not needed, achieving maximum asset utilization and flexibility. This feature provides the safety from unexpected and dangerous shutdowns that can occur with power systems without power management when operated in a similar way. Series and Parallel Operation To increase the available power, similarly rated outputs can be operated in series for greater output voltage or in parallel for greater output current. To simplify parallel operation, the N6700 offers virtual channels, a firmware based feature that allows the N6700 system to treat up to 4 channels as a single, synchronized channel. Once configured, all functions (sourcing, measurements, triggering, protection, and status monitoring) behave as if there is 1 channel of up to 4 times the capacity of a single channel, without writing a single line of code to manage the interaction and synchronization of the paralleled power supplies. Voltage 20 V 35 V 60 V 100 V Current 1 15 A2 8.5 A 5A 3A Power 300 W 300 W 300 W 300 W Voltage 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% + 100 mV Current 0.15% + 60 mA 0.15% + 60 mA 0.15% + 60 mA 0.15% + 30 mA Voltage 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% + 100 mV Current 0.15% + 15 mA 0.15% + 12 mA 0.15% + 12 mA 0.15% + 6 mA 20 mV 3 mV 22 mV 5 mV 35 mV 9 mV 45 mV 18 mV Voltage 13 mV 16 mV 24 mV 45 mV Current 6 mA 6 mA 6 mA 6 mA Voltage 2 mV 4 mV 6 mV 10 mV Current 1 mA 1 mA 1 mA 1 mA Programming Accuracy (at 23C 5C) Readback Accuracy (at 23C 5C) Output Ripple and Noise (PARD) (from 20 Hz to 20 MHz) CV peak-to-peak CV rms Load Regulation4 Line Regulation Transient Response Time (time to recover to within the settling band following a load change from 50% to 100% and from 100% to 50% of full load.) Voltage settling band 0.3 V 3 0.3 V 3 0.5 V 1.0 V Time <250 s <250 s <250 s <250 s Voltage 7 mV 10 mV 18 mV 28 mV Current 9 mA 6 mA 3 mA 1.5 mA 6 mA 6 mA 6 mA 6 mA Accuracy 0.25% + 100 mV 0.25% + 130 mV 0.25% + 260 mV 0.25% + 650 mV Accuracy w/opt 760 0.25% + 700 mV 0.25% + 700 mV 0.25% + 400 mV 0.25% + 650 mV Accuracy w/opt 761 0.25% + 500 mV 0.25% + 350 mV 0.25% + 350 mV 0.25% + 650 mV 22 V 38.5 V 66 V 110 V Programming Resolution Output Ripple and Noise (PARD) CC rms Over-voltage Protection Maximum setting Response Time 50 s from ocurence of OV condition to start of output shutdown Maximum Up-programming Time with full resistive load: (time from 10% to 90% of total voltage excursion) Voltage setting from 0 V to 10 V 20 ms 20 ms 20 ms 20 ms Maximum Up-programming Settling Time with full resistive load: (time from start of voltage change to within 50 mV of final value) Voltage setting from 0 V to 10 V 100 ms 100 ms 100 ms 100 ms 1 Output current is derated 1% per C above 40C. 2 When relay Option 760 is installed, the maximum output current will be limited to 10 A. 3 When relay Option 760 or 761 is installed, the settling band is 0.35 V. 4 With output change from no load to full load, up to a maximum load-lead drop of 1 V/lead. More detailed specifications at www.agilent.com/find/N6700 71 High Performance DC Power Supplies speed and accuracy for test optimization Low-Profile Modular Power System 50-300 W GPIB (Continued) Specifications N6731B N6732B N6733B N6734B N6735B N6736B Voltage 5V 8V 20 V 35 V 60 V 100 V Current 10 A 6.25 A 2.5 A 1.5 A 0.8 A 0.5 A Power 50 W 50 W 50 W 50 W 50 W 50 W Voltage 0.1% + 19 mV 0.1% + 19 mV 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% + 100 mV Current 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 10 mA Voltage 0.1% + 20 mV 0.1% + 20 mV 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% + 100 mV Current 0.15% + 20 mA 0.15% + 10 mA 0.15% + 5 mA 0.15% + 4 mA 0.15% + 4 mA 0.15% + 2 mA (at 0 to 55 C, and derated above 40 C) Output Ratings Triggering The N6700 MPS mainframe has hardware trigger in/trigger out signals which permit the N6700 to be synchronized with external events. Output Disconnect Relays Modules in the N6700 can be individually ordered with optional Output Disconnect Relays (option 761) or Output Disconnect/Polarity Reversal Relays (option 760). With option 761, Output Disconnect Relays, mechanical relays disconnect both the plus and minus side of the power supply, including the sense leads. With option 760, Output Disconnect/Polarity Reversal Relays switch the leads on both the plus and minus side of the power supply, including the sense leads, resulting in a voltage polarity reversal at the DUT. Universal AC Input The N6700 has a universal input that operates from 100-240 Vac, 50/60/400 Hz. There are no switches to set or fuses to change when switching from one voltage standard to another. The AC input employs power factor correction. Programming Accuracy2 (at 23C 5C) Readback Accuracy (at 23C 5C) Output Ripple and Noise (PARD) (from 20 Hz - 20 MHz) CV peak-to-peak 10 mV 12 mV 14 mV 15 mV 25 mV 30 mV CV rms 2 mV 2 mV 3 mV 5 mV 9 mV 18 mV 5 mV 2 mA 6 mV 2 mA 9 mV 2 mA 11 mV 2 mA 13 mV 2 mA 20 mV 2 mA Voltage Current 1 mV 1 mA 2 mV 1 mA 2 mV 1 mA 4 mV 1 mA 6 mV 1 mA 10 mV 1 mA Transient Response Time (time to recover to within the settling band following a load change from 50% to 100% and from 100% to 50% of full load.) Voltage settling band 80 mV 80 mV 200 mV 200 mV 400 mV 500 mV Time 200 s 200 s 200 s 200 s 200 s 200 s Load Regulation1 Voltage Current Line Regulation 1 With an output change from no load to full load, up tp a maximum load-lead drop of 1 V per lead. 2 Applies from minimum to maximum programming range. (see Supplemental Characteristics) N6760 Family Choosing the right DC Power Modules to meet your ATE needs N6750 Family The Agilent N6750 family of highperformance, autoranging DC power modules provides low noise, high accuracy and includes, autoranging output capabilities enabling one power supply to do the job of several traditional power supplies. In addition, it includes optional high-speed test extensions that offers an oscilloscope-like digitizer and ultra-fast programming speed. The Agilent N6760 family of precision DC power modules provides precise control and measurements in the milliampere and microampere region with the ability to simultaneously digitize voltage and current, and capture those measurements in an oscilloscope-like data buffer. These precision DC power modules offer dual ranges on both programming and measurement and are ideally suited for semiconductor and passive device testing. N6750/60 Low Noise Outputs This switching power supply outperforms most linear power supplies on the market with low normal and common mode noise. More detailed specifications at www.agilent.com/find/N6700 72 High Performance DC Power Supplies speed and accuracy for test optimization Low-Profile Modular Power System 50-300 W GPIB (Continued) Specifications N6731B N6732B N6733B N6734B N6735B N6736B (at 0 to 55 C, and derated above 40 C) Supplemental Characteristics N6750/60 Output Programming Speed The N6750/60 achieves performance unlike a typical DC power supply with up to 10 to 50 times faster than other programmable power supplies. Thanks to an active downprogramming circuit to rapidly pull down the output when lowering the module's output voltage, the N6750/60 can rapidly program both up and down in voltage. These output speeds allow the N6750/60 to give maximum system throughput when your test calls for frequent changes in power supply voltage settings. (Non-warranted characteristics determined by design that are useful in applying the product) Programming Resolution Voltage 3.5 mV 4 mV 7 mV 10 mV 18 mV 28 mV Current 7 mA 4 mA 3 mA 2 mA 1 mA 0.5 mA 8 mA 4 mA 2 mA 2 mA 2 mA 2 mA Accuracy (without relay option) 0.25% + 50 mV 0.25% + 50 mV 0.25% + 75 mV 0.25% + 100 mV 0.25% + 200 mV 0.25% + 250 mV Response Time 50 s from occurence of OV condition to start of output shutdown Output Ripple and Noise (PARD) CC rms Over-voltage Protection Maximum Up-programming and Down-programming Time with full resistive load: (time from 10% to 90% of total voltage excursion) Voltage setting from 0 V to full scale and full scale to 0 V 20 ms 20 ms 20 ms 20 ms 20 ms 20 ms Maximum Up-programming and Down-programming Settling Time with full resistive load: (time from start of voltage change until voltage settles within 0.1% of the full-scale voltage of its final value) N6750/60 Autoranging for Flexibility The N6750/60 gives test system designers even more flexibility by providing autoranging outputs. This autoranging capability provides maximum output power at any output voltage up to 50 V. This allows one power supply to do the job of several power supplies because its operating range covers low voltage, high current as well as high voltage, low current operating points. N6750/60 High-Speed Test Extensions To make your testing go even faster, the N6750/60 offer High-Speed Test Extensions (HSTE) which comes standard on the N6760 and optional on the N6750. This enhancement to the N6750/60 DC Power Modules extends the capabilities to include features similar to a built-in arbitrary waveform generator and a built-in oscilloscope. Through the LIST mode of HSTE, you can download up to 512 setpoints of voltage Voltage setting from 0 V to full scale and full scale to 0 V 100 ms 100 ms and current. In LIST mode, you can program the output to execute a LIST of voltage and current setpoints. For each setpoint, a dwell time can be specified and the power supply will stay (i.e., dwell) at that setpoint for the programmed dwell time value. The HSTE also provides an oscilloscope-like digitizer built into the power module to capture voltage and current measurements. N6730/40/70 Family The Agilent N6730, N6740, and N6770 families of DC power modules provide programmable voltage and current, measurement 100 ms 100 ms 100 ms 100 ms and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources, such as fixture control. The N6730/40/70 families give you clean, reliable DC power without advanced features, plus gives you the added benefits of being apart of the N6700 MPS including small size (true 1U), mix-and-match with other N6700 DC Power Modules when you need performance along with basic DC outputs, connectivity via LAN, USB, and GPIB, and fast command processing time of less than 1 ms. More detailed specifications at www.agilent.com/find/N6700 73 High Performance DC Power Supplies speed and accuracy for test optimization Low-Profile Modular Power System 50-300 W GPIB (Continued) Specifications N6741B N6742B N6743B N6744B N6745B N6746B Voltage 5V 8V 20 V 35 V 60 V 100 V Current 20 A 12.5 A 5A 3A 1.6 A 1A Power 100 W 100 W 100 W 100 W 100 W 100 W Voltage 0.1% + 19 mV 0.1% + 19 mV 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% + 100 mV Remote Sensing: Output can maintain specifications with up to 1-volt drop per load lead Current 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 20 mA 0.15% + 10 mA Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 1ms. Voltage 0.1% + 20 mV 0.1% + 20 mV 0.1% + 20 mV 0.1% + 35 mV 0.1% + 60 mV 0.1% + 100 mV Current 0.15% + 20 mA 0.15% + 10 mA 0.15% + 5 mA 0.15% + 4 mA 0.15% + 4 mA 0.15% + 2 mA (at 0 to 55 C, and derated above 40 C) Ouput Ratings Supplemental Characteristics for all model numbers DC Floating Voltage: Output terminals can be floated up to 240 VDC from chassis ground Programming Accuracy2 (at 23C 5C) Readback Accuracy (at 23C 5C) Output Ripple and Noise (PARD) (from 20 Hz - 20 MHz) High Speed Test Extentions: CV peak-to-peak 11 mV 12 mV 14 mV 15 mV 25 mV 30 mV List Mode: CV rms 2 mV 2 mV 3 mV 5 mV 9 mV 18 mV * Number of steps = 1 to 512 Load Regulation1 * Dwell time = 1 to 262 s Voltage Current 5 mV 2 mA 6 mV 2 mA 9 mV 2 mA 11 mV 2 mA 16 mV 2 mA 30 mV 2 mA Voltage Current 1 mV 1 mA 2 mV 1 mA 2 mV 1 mA 4 mV 1 mA 6 mV 1 mA 10 mV 1 mA Transient Response Time (time to recover to within the settling band following a load change from 50% to 100% and from 100% to 50% of full load.) * Maximum list repetitions = 256, or infinite Digitizer: * Measurement points = 1 to 4096 * Sample rate = 0.000025 Hz to 50 kHz Line Regulation Voltage settling band 100 mV 100 mV 300 mV 300 mV 500 mV 1000 mV Time 200 s 200 s 200 s 200 s 200 s 200 s I/O Interface: Programming Resolution GPIB, LAN, USB standard Voltage 3.5 mV 4 mV 7 mV 10 mV 18 mV 28 mV Current 7 mA 4 mA 3 mA 2 mA 1 mA 0.5 mA 8 mA 4 mA 2 mA 2 mA 2 mA 2 mA 0.25% + 50 mV 0.25% + 75 mV 0.25% + 100 mV 0.25% + 200 mV 0.25% + 250 mV Software Driver: * IVI-COM * VXIPlug&Play Output Ripple and Noise (PARD) CC rms Over-voltage Protection AC Input: Accuracy (without relay option) * Input Range: 85 - 265 VAC; 50/60/400 Hz 0.25% + 50 mV Response Time 50 s from occurence of OV condition to start of output shutdown * Power Consumption: Maximum Up-programming and Down-programming Time with full resistive load: (time from 10% to 90% of total voltage excursion) N6700B-1000 VA typical (with power factor correction) N6701A-1500 VA typical (with power factor correction) N6702A-3000 VA typical (with power factor correction) Voltage setting from 0 V to full scale and full scale to 0 V 20 ms 20 ms 20 ms 20 ms 20 ms 20 ms Maximum Up-programming and Down-programming Settling Time with full resistive load: (time from start of voltage change until voltage settles within 0.1% of the full-scale voltage of its final value) Voltage setting from 0 V to full scale and full scale to 0 V 100 ms 100 ms 100 ms 100 ms 100 ms 100 ms 1 With an output change from no load to full load, up tp a maximum load-lead drop of 1 V per lead. 2 Applies from minimum to maximum programming range. (see Supplemental Characteristics) More detailed specifications at www.agilent.com/find/N6700 74 High Performance DC Power Supplies speed and accuracy for test optimization Low-Profile Modular Power System 50-300 W GPIB (Continued) Specifications N6700B N6701A N6702A (at 0 to 55 C, and derated above 40 C) Supplemental Characteristics Regulatory Compliance: European EMC directive 89/336/EEC for Class A products, Australian C-Tick mark, This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme a la norme NMB-001 du Canada. European Low Voltage Directive 73/23/EEC. Maximum Total Output Power (= Sum of total module output power) (Non-warranted characteristics determined by design and useful in applying the product) 400 W when operating from 100 -240 VAC input 600 W when operating from 100 -240 VAC input 1200 W when operating from 200 -240 VAC input 600 W when operating from 100 -120 VAC input Size: * Height 44.45 mm; 1.75 in * Width 432.5 mm; 17.03 in * Depth (including handles) 585.6 mm; 23.06 in (N6700B/N6701A) 633.9 mm; 24.96 in (N6702A) Weight: * N6700B with 4 installed modules Net: 12.73 kg; 28 lbs. * N6701A with 4 installed modules Net: 11.82 kg; 26 lbs. * N6702A with 4 installed modules Net: 14.09 kg; 31 lbs. * Single power module Net: 1.23 kg; 2.71 lbs. Warranty Period: One year Ordering Information Options for N6700 Mainframes Opt 908 Rack Mount Kit Opt FLR Filler Panel Kit Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 900 Power Cord, United Kingdom Opt 901 Power Cord, Australia Opt 902 Power Cord, Europe Opt 903 Power Cord, USA, Canada, 120 V Opt 904 Power Cord, USA, Canada, 240 V Opt 906 Power Cord, Switzerland Opt 912 Power Cord, Denmark Opt 917 Power Cord, South Africa, India Opt 918 Power Cord, Japan Opt 919 Power Cord, Israel Opt 920 Power Cord, Argentina Opt 921 Power Cord, Chile Opt 922 Power Cord, China Opt 927 Power Cord, Thailand Accessories for N6700 Mainframes N6709A Rack Mount Kit (Opt 908) Required for rack mounting of N6700B, N6701A, N6702A, N6710B, N6711A, or N6712A. Standard rack mount hardware will not work) Options for Modules Opt 760 Open/Close and Polarity Reverse Relays (only available at time of order on models N6731B-N6736B, N6742B-N6746B, N6773A-N6776A) Opt 761 Output Disconnect Relays (only available at time of order) Opt UK6 Commercial calibration with test result data Opt 1A7 ISO 17025 Cal Certificate Opt 054 High-Speed Test Extension (N675x only) Comes standard on the N676xA, not available on N673x/4x/7x N6708A Filler Panel Kit (Opt FLR) Required when you have < 4 modules in an N6700B, N6701A, or N6702A. Each filler panel kit contains 3 filler panels. More detailed specifications at www.agilent.com/find/N6700 75 High Performance DC Power Supplies speed and accuracy for test optimization Modular Power System 1200 W per mainframe GPIB Modular system permits up to 8 outputs of 150 W per output in 4 U of rack space Reconfigure fast with easily swappable modules Fast, low-noise outputs LIST mode and advance triggering system Optional isolation and polarity reversal relays Built-in measurements and advanced programmable features Protection features to ensure DUT safety 66000A (mainframe) 66001A (keyboard) 66000 Modular Power System The Agilent 66000 modular power system simplifies test-system assembly, cabling, programming, debugging and operation. It is ideal for ATE and production test environments, where it can supply bias power and stimulus to subassemblies and final products. The modular power system saves rack space, the 7-inch-high (4-EIA units) mainframe can accommodate up to eight DC power modules. Key Features * GPIB-programmable voltage and current * Programmable over-voltage and over-current protection * Self-test initiated at power-up or from GPIB command * Electronic calibration over GPIB or from keyboard * Over-temperature protection * Discrete fault indicator/remote inhibit (DFI/RI) * Five nonvolatile store-recall states per output * User-definable power-on state Multiple Mainframes at One GPIB Address The Agilent serial link feature will allow you to control up to 16 outputs at one GPIB address by connecting an auxiliary mainframe. The serial link cable comes standard with the Specifications 66101A 66102A 66103A 66104A 66105A 66106A (at 0 to 55 C unless otherwise specified) Output ratings at 40C Output voltage 0 to 8 V 0 to 20 V 0 to 35 V 0 to 60 V 0 to 120 V Output current 0 to 16 A 0 to 7.5 A 0 to 4.5 A 0 to 2.5 A 0 to 1.25 A 0 to 0.75 A 0 to 200 V Maximum power 128 W 150 W 150 W 150 W 150 W 150 W Programming accuracy at 25C 5C Voltage 0.03% + 3 mV 8 mV 13 mV 27 mV 54 mV 90 mV Current 0.03% + 6 mA 3 mA 2 mA 1.2 mA 0.6 mA 0.4 mA Voltage 0.02%+ 2 mV 5 mV 8 mV 16 mV 32 mV 54 mV Current 0.02%+ 6 mA 3 mA 2 mA 1 mA 0.6 mA 0.3 mA Constant Voltage rms 2 mV 3 mV 5 mV 9 mV 18 mV 30 mV peak-peak 5 mV 7 mV 10 mV 15 mV 25 mV 50 mV Constant Current rms 8 mA 4 mA 2 mA 1 mA 1 mA 1 mA Voltage 0.5 mV 0.5 mV 1 mV 2 mV 3 mV 5 mV Current 0.75 mA 0.5 mA 0.3 mA 0.1 mA 50 A 30 A Voltage 1 mV 1 mV 1 mV 2 mV 4 mV 7 mV Current 0.5 mA 0.2 mA 0.2 mA 0.1 mA 50 A 30 A Transient response time Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any step change in load current up to 10 percent of rated current Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying the product) Readback accuracy (via GPIB or keyboard display at 25C 5C) Ripple and noise (20 Hz to 20 MHz) Line regulation Load regulation Average resolution Voltage 2.4 mV 5.9 mV 10.4 mV 18.0 mV 36.0 mV Current 4.6 mA 2.3 mA 1.4 mA 0.75 mA 0.39 mA 60.0 mV 0.23 mA Output voltage programming (OVP) 50 mV 120 mV 200 mV 375 mV 750 mV 1.25 mV OVP accuracy 250 mV 500 mV 800 mV 1V 1.5 V 2.5 V More detailed specifications at www.agilent.com/find/66000 76 High Performance DC Power Supplies speed and accuracy for test optimization Modular Power System 1200 W per mainframe GPIB (Continued) Specifications 66101AJ03 66101AJ05 66102A- 66103AJ05 J01 66103AJ02 Special Order Option Special Order Option Special Order Option Special Order Option Special Order Option Output voltage 5.7 V 12 V 15 V 37 V 40 V Output current 20 A 12 A 10 A 4.5 A 3.6 A Maximum power 114 W 144 W 150 W 167 W 144 W (at 0 to 55 C unless otherwise specified) Output ratings at 40C 66000 MPS mainframe. For applications with a broader range of power requirements, one 66000 mainframe can be connected with up to eight of the 6640, 6650, 6670, 6680, 6690 or 6030 series of system power supplies. This solution provides power ranges from 150 watts to 5000 watts at one primary GPIB address. Programming accuracy at 25C 5C Voltage 0.03% + 2.5 mV 5 mV 8 mV 13 mV 15 mV Current 0.03% + 8 mA 6 mA 4 mA 2 mA 2 mA Readback accuracy (via GPIB keyboard display at 25C 5C) Voltage 0.02% + 2 mV 3 mV 5 mV 8 mV 9.2 mV Output Connections Current 0.02% + 8 mA 6 mA 4 mA 2 mA 2 mA System assembly is simplified thanks to a quick-disconnect connector assembly on each module. Once your wires are connected to the load, the connector design permits the modules to be removed from the front of the mainframe without disconnecting cabling or removing the mainframe from the rack. One connector assembly is shipped with each module. Ripple and noise (20 Hz to 20 MHz) Constant Voltage rms 2 mV 3 mV 3 mV 5.3 mV 6 mV peak-peak 5 mV 7 mV 7 mV 10.6 mV 11.5 mV Constant Current rms 10 mA 8 mA 6 mA 2 mA 2 mA Voltage 0.5 mV 0.5 mV 0.5 mV 1 mV 1 mV Current 0.5 mA 0.75 mA 0.5 mA 0.3 mA 0.3 mA Voltage 1 mV 1 mV 1 mV 1 mV 1 mV Current 1 mA 0.5 mA 0.3 mA 0.2 mA 0.2 mA Transient response time Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any step change in load current up to 10 percent of rated current Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying the product) Line regulation Load regulation Output Sequencing Increase test throughput by using the output sequencing feature of the 66000 MPS. This powerful feature allows you to download up to 20 voltage, current, and dwell-time parameter sets per output. This sequence can be paced by the programmed dwell times. As an alternative, triggers can be used to step through the output list. The output sequences can be executed without controller intervention, thereby increasing overall test system throughput. More detailed information on the triggering and output sequencing capabilities can be obtained by ordering the 66000 Modular Power System Product Note (p/n 5091-2497E) described below. Average resolution Voltage 2 mV 3.6 mV 4.5 mV 11 mV Current 6 mA 4.6 mA 3.1 mA 1.4 mA 12 mV 1.2 mA OVP 45 mV 75 mV 90 mV 200 mV 230 mV OVP accuracy 250 mV 375 mV 375 mV 850 mV 920 mV Application Notes: 66000 Modular Power System Product Note 5988-2800EN 10 Hints for Using Your Power Supply to Decrease Test Time 5968-6359E 10 Practical Tips You Need to Know About Your Power Products 5965-8239E Agilent DC Power Supplies for Base Station Testing 5988-2386EN More detailed specifications at www.agilent.com/find/66000 77 High Performance DC Power Supplies speed and accuracy for test optimization Modular Power System 1200 W per mainframe GPIB (Continued) Specifications 66103AJ09 66103AJ12 66104AJ09 66105AJ01 Special Order Option Special Order Option Special Order Option Special Order Option Output voltage 28.5 V 24 V 55 V 35 V Output current 5.5 A 6A 3A 1.25 A Maximum power 157 W 144 W 165 W 44 W (at 0 to 55 C unless otherwise specified) Output ratings at 40C Supplemental Characteristics for all model numbers DC Floating Voltage: Output terminals can be floated up to 240 Vdc from chassis ground Programming accuracy at 25C 5C Remote Sensing: Up to half the rated output voltage can be dropped across each load lead. Add 2 mV to the voltage load regulation specification for each 1-V change in the negative output lead caused by a load current change. Readback accuracy (via GPIB or keyboard display at 25C 5C) Command Processing Time: The average time for the output voltage to change after getting an GPIB command is 20 ms Voltage 0.03% + 13 mV 13 mV 25 mV 15 mV Current 0.03% + 3 mA 3 mA 1.5 mA 0.6 mA Voltage 0.02% + 8 mV 8 mV 15 mV 9 mV Current 0.02% + 3 mA 3 mA 1.2 mA 0.6 mA Constant Voltage rms 5 mV 5 mV 9 mV 6 mV peak-peak 10 mV 10 mV 15 mV 11.5 mV Constant Current rms 4 mA 4 mA 1.2 mA 1 mA Voltage 1 mV 1 mV 2 mV 1 mV Current 0.3 mA 0.3 mA 0.1 mA 50 A Voltage 1 mV 1 mV 2 mV 1 mV Current 0.2 mA 0.2 mA 0.1 mA 50 A Transient response time Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any step change in load current up to 10 percent of rated current AC Input of System Mainframe Supplemental Characteristics Voltage 100 Vac 120 Vac 200 Vac 220 Vac 230 Vac 240 Vac Max. 29 A 25 A 16 A 16 A 15 A 15 A Current (Non-warranted characteristics determined by design that are useful in applying the product) Average resolution Input Power of System Mainframe: 3200 VA (max.), 1800 W (max.), 1600 W (typ.) Voltage 10.4 mV 8 mV 16.5 mV 2 mV Current 2 mA 2 mA 0.9 mA 1.2 mA Output Programming Response Time (with full resistive load): The rise and fall time (10% to 90% and 90% to 10%) of the output voltage is less than 20 ms. The output voltage change settles within 0.1% of the final value in less than 120 ms. Down Programming: An active downprogrammer sinks approximately 10% of the rated output current Ripple and noise (20 Hz to 20 MHz) Line regulation Load regulation Calibration Interval: One year GPIB Capabilities: SH1, AH1, TE6, LE4, SR1, RL1, PP0, DC1, DT1, E1, and C0, and a command set compatible with IEEE-488.2 and SCPI OVP 200 mV 150 mV 350 mV 230 mV OVP accuracy 800 mV 600 mV 950 mV 920 mV Software Driver: VXIPlug&Play Regulatory Compliance: Listed to UL 1244; certified to CSA 22.2 No. 231; conforms to IEC 61010-1. Weight: Net, 66000A, 15 kg (33 lb); 66001A, 1.05 kg (2.3 lb); 66101-66106A, 2.8 kg (6 lb). Shipping, 66000A, 19 kg (42 lb); 66001A, 1.34 kg (2.95 lb); 66101-66106A, 4.1 kg (9 lb). Size: 66000A: 425.7 mm W x 192 mm H x 677.93 mm D (16.76 in x 7.28 in x 26.69 in), including feet and rear connectors Warranty Period: One year More detailed specifications at www.agilent.com/find/66000 78 High Performance DC Power Supplies speed and accuracy for test optimization Modular Power System 1200 W per mainframe GPIB (Continued) Ordering Information 66000A MPS Mainframe * Opt 908 Rack-mount Kit (p/n 5063-9215) * Opt 909 Rack-mount Kit with Handles (p/n 5063-9222) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Note: Options 908 and 909 require cabinet rails (E3663AC) or a slide kit (p/n 1494-0059) to support the loaded mainframe's weight. A line cord option must be specified, see the AC line voltage and cord section. p/n 66000-90001 Mainframe Installation Guide p/n 5959-3360 DC Power Module User's Guide p/n 5959-3362 DC Power Module Programming Guide p/n 66000-90003 Mainframe Service Manual p/n 5959-3364 DC Power Module Service Manual p/n 1252-1488 4-Pin FLT/Inhibit Connector E3663AC Support rails for Agilent rack cabinets Module Options Opt 760 Open/Close and Polarity Reversal Relays Opt J17 External Imon Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual Accessories p/n 5060-3351 Field-Installable Relay Kit p/n 5060-3386 Standard Connector Assembly p/n 5060-3387 Standard Connector Assembly with installed relays (Option 760) 66001A MPS Keyboard includes 2m (6 ft) cables 66002A Rack kit for 66001A keyboard Agilent Models: 66000A Top 677.9mm 26.69" 104.9mm 4.13" Front 425.7mm 16.76" 190mm 7.5" 177.3mm 6.98" More detailed specifications at www.agilent.com/find/66000 79 Application Specific DC Power Supplies... tailored solutions for specific needs Some applications require specialized DC power supplies. This section contains DC power supplies that provide the solutions needed to solve some very specific application problems. Mobile Communication DC Sources Battery life is a critical parameter for battery powered digital mobile communications devices such as cell phones, WLAN and BluetoothTM enabled appliances. The pulsed characteristics of battery drain create unique powering and measuring requirements. With fast transient response, to react to pulsed current draw, and a flexible and fast measurement system, these DC sources are optimized for the needs of digital mobile communications devices. Solar Array Simulators Solar panels consisting of multiple solar arrays provide power to satellites. They have unique V-I characteristics. Since the output power of a solar array varies with environmental conditions (i.e. temperature, darkness, light intensity), a specialized power supply must be used for accurate simulation. Component Test DC Source Mixed signal IC testing requires speed, accuracy, and multiple DC outputs. This quad output DC source provides cost effective and compact biasing and measurement for semiconductor test systems. More detailed specifications at www.agilent.com/find/power 80 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 40-100 W Ideal for testing wireless and battery powered devices Several times improvement in measurement throughput over general purpose DC sources Superior output transient performance with short or long load leads (up to 6 meters) Dynamic measurement system for accurate battery current drain measurement Easy-to-use Graphical User Interface and analysis tools for bench top use 66319B/D, 66321B/D Specifications 66309B/D 66311B 66319B/D 66321B/D 66332A (at 0 to 55 C unless otherwise specified) Overcome Battery Powered Device Testing Challenges Digital communications devices and digital battery powered devices present a unique testing challenge: they draw rapid pulses of current. By offering superior transient performance, unmatched in the marketplace, the Agilent Mobile Communications DC Sources dramatically reduce the transient voltage drop due to pulse loading characteristics of digital communications devices. The Agilent Mobile Communications DC Sources enable you to maximize test throughput by minimizing test interruption due to false trigger of device low voltage shutdown. Dynamic Measurement Capabilities The Agilent Mobile Communications DC Sources offer a built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes (such as talk mode, active mode, standby mode, and off/sleep mode). Measurements made during these modes are critical for ensuring that your devices are operating properly and that you are getting the most out of the battery. Simulate both Main Battery and Charger Single output models are recommended when you need to provide power as a replacement to your 66332AJ01 Special Order Option Number of outputs 2 1 2 1 1 1 GPIB Yes Yes Yes Yes Yes Yes Voltage 0 to 15 V 0 to 15 V 0 to 15 V 0 to 15 V 0 to 20 V 0 to 30 V Current 0 to 3 A 0 to 3 A 0 to 3 A 0 to 3 A 0 to 5 A 0 to 3.3 A Peak current for up to 7 ms 5A 5A 5A 5A 5A 3.3 A Output ratings Programming accuracy at 25C 5C (% of setting plus fixed) Voltage 0.05%+ 10 mV 10 mV 10 mV 10 mV 10 mV 15 mV +Current 0.05%+ 1.33 mA 1.33 mA 1.33 mA 1.33 mA 2 mA 2 mA Ripple and Noise (20 Hz to 20 MHz) Voltage rms 1 mV 1 mV 1 mV 1 mV 0.3 mV 0.5 mV peak-to-peak 6 mV 6 mV 6 mV 6 mV 3 mV 5 mV rms 2 mA 2 mA 2 mA 2 mA 2 mA 2 mA 0.03%+ 5 mV 5 mV 5 mV 5 mV 3 mV 5 mV 0.5 mA2 0.5 mA2 -- -- 0.5 mA 0.5 mA Current DC measurement accuracy Voltage +20 mA to + rated current 0.2%+ -20 mA to - rated current 1.1 mA 1.1 mA -- -- 1.1 mA 1.1 mA -3 A to + 5 A 0.2%+ 0.2% -- -- 0.5 mA2 0.5 mA2 -- -- -1 A to + 1 A 0.1% -- -- 0.2 mA 0.2 mA -- -- 2.5 A 2.5 A 2.5 A 2.5 A 2.5 A 2.5 A -20 mA to + 20 mA range 0.1%+ Dynamic measurement system Buffer size 4096 points 4096 points 4096 points 4096 points 4096 points 4096 points Sampling interval 15 s 31,200 s 15 s 31,200 s 15 s 31,200 s 15 s 31,200 s 15 s 31,200 s 15 s 31,200 s Transient response time <35 s3 <35 s3 <20 s3 <20 s <100 s4 <100 s4 Transient voltage dip (typical with up to 15 feet 22 AWG wiring) 70 mV 70 mV 40 mV 40 mV 500 mV 650 mV Range --- -- -40 m to +1 -40 m to -- +1 -- Programming accuracy -- -- 0.5% + 2 m 0.5% + 2 m -- -- Resolution -- -- 1 m 1 m -- -- Programmable output resistance More detailed specifications at www.agilent.com/find/66300 81 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 40-100 W (Continued) Specifications 66309B/D 66311B 66319B/D 66321B/D 66332A (at 0 to 55 C unless otherwise specified) device's main battery during testing. Dual output models are recommended when you need to provide power as a replacement to your device's main battery and when you need to simulate the battery charger power; Use one output to supply current to the battery charger input port and the second output to connect in place of the main battery (which sinks current to simulate the main battery being charged). Performs Like a Battery With their battery emulation features, the Agilent 66319B/D and 66321B/D allow you to test your devices under the same power conditions that exist in actual use. Emulating the battery is key when characterizing battery operating life and detecting early product failures. These DC sources simulate the effects of internal resistance of the battery, enabling them to emulate the operation of various battery types or batteries in different charge states. Plus, these DC sources can simulate negative resistance so that you can compensate for voltage drop due to wiring in a fixture. Feature Summary Agilent has designed in the capability and flexibility that is required for accurately testing today's communications devices as well as your next generation designs for cell phones (formats include: 3G, cdma2000, WCDMA, CDMA, TDMA, GSM, PCS, DECT, TETRA, PHS, NADC), PDAs, BluetoothTM enabled devices, and Wireless LAN access devices. 66332AJ01 Special Order Option Voltmeter input (66309D, 66319D, and 66321D only) Input range -25 to +25 Vdc -- -- -25 to +25 Vdc -25 to +25 Vdc -- -- -- -- DC readback accuracy (at 25C 5C) 0.04% + 5 mV -- -- 0.04% + 5 mV 0.04% + 5 mV -- -- -- -- AC + DC readback accuracy (at 25C 5C) with DC plus a sinewave input > 25 mV rms 1% + 5 mV (60 Hz to 10 kHz) -- -- -- -- 1% + 5 mV (60 Hz to 10 kHz) 1% + 5 mV (60 Hz to 10 kHz) -- -- -- -- -- -- -- -- Voltage 0 to 12V -- 0 to 12V -- -- -- Current 0 to 1.5 A -- 0 to 1.5 A -- -- -- Voltage 0.2% + 40 mV -- 0.2% + 40 mV -- -- -- +Current 0.2% + 4.5 mA -- 0.2% + 4.5 mA -- -- -- 0.2% + 15 mV -- 0.2% + 15 mV -- -- -- 0.2% + 3 mA -- 0.2% + 3 mA -- -- -- Auxilary output (66309B/D and 66319B/D) Output ratings Programming accuracy DC measurement accuracy Voltage +Current Ripple and Noise (20 Hz to 20 MHz) Voltage rms peak-to-peak 1 mV 6 mV -- 1 mV 6 mV -- -- -- Current rms 2 mA -- 2 mA -- -- -- Notes: 1 66332A also has RS-232 interface. 2 Applies with current detector set to DC. 3 Time for the output voltage to recover to within 20 mV of final value after 0.1 to 1.5 A load change in high capacitance compensation range. 4 Time for the output voltage to recover to within 20 mV or 0.1% of the voltage rating of the unit following a change in load current of up to 50% of the output current rating. Supplemental Characteristics (Non-warranted characteristics determined by design and useful in applying the product) DC Floating Voltage Output terminals can be floated up to +/- 50 Vdc maximum from chassis ground (+/- 240 Vdc for 66332A) Remote Sensing Voltage Drop For 66332A: Up to 2 V can be dropped in each load lead. Add 2 mV to the load regulation specification for each 1 V drop in the positive output lead. For 66309B/D, 66311B: Up to 4 V can be dropped in each load lead. Add 2 mV to the load regulation specification for each 1 V drop in the positive output lead. For 66319B/D main output, 66321B/D main output: Up to 3 V total can be dropped in both load leads. For 66319B/D auxiliary output, 66321B/D auxiliary output: Up to 4 V total can be dropped in both load leads. Command Processing Time Average time required for the output voltage to begin to change following receipt of GPIB data is 4 ms (with display disabled). More detailed specifications at www.agilent.com/find/66300 82 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 40-100 W (Continued) Supplemental Characteristics (Non-warranted characteristics determined by design and useful All models offer: * Fast output response technology * Programmable output response compensation * Advanced DSP-based dynamic measurements * Current sinking for testing and calibrating charger circuitry * Extensive protection features (including broken sense lead detection) * GPIB Interface, SCPI (Standard Commands for Programmable Instruments), VXIplug&play drivers In addition, the 66319B/D and 66321B/D high performance models offer: * Output resistance programming (positive and negative) * Superior output stability with up to 6 meters of load leads * Excellent transient voltage drop (typically < 30 mV) * Three current measurement ranges * NEW! Additional advanced battery drain measurements (CCDF, long term battery drain) in applying the product) (Continued) Output Programming Response Time For 66332A: The rise and fall time (10/90% and 90/10%) of the output voltage is < 2 ms (400 s in fast mode). The output voltage change settles within 1 LSB (0.025% x full scale voltage) of final value in < 6 ms (2 ms in fast mode). For 66311B, 66321B/D, 66309B/D output 1, 66319B/D output 1: The rise and fall time (10/90% and 90/10%) of the output voltage is < 200 s. Input power (at worst case conditions: full load, 100 Vac mains) For 66311B, 66321B/D: 1.7 A, 125 W. For 66309B/D, 66319B/D: 2 A, 170 W. For 66332A: 3.5 A, 250 W. Measurement Time Average time to process query, calculate measurement parameter and return data is 50 ms (includes the default time of 30 ms for acquiring data and 20 ms data processing overhead). Size For 66309B/D, 66311B, 66319B/D, 66321B/D: 212.8 mm W x 88.1 mm H x 435 mm D (8.4 in x 3.5 in x 17.13 in). For 66332A: 425.5 mm W x 88.1 mm H x 364.4 mm D (16.8 in x 3.5 in x 14.3 in). GPIB Interface Capabilities IEEE-488.2, SCPI command set, 6630A series programming capability (not supported in 66309B/D, 66319B/D, 66321B/D) Weight For 66309B/D, 66311B, 66319B/D, 66321B/D: 9.07 kg (20 lb) net, 11.1 kg (24.5 lb) shipping. For 66332A: 12.7 kg (28 lb) net, 15.0 kg (33 lb) shipping. Regulatory Compliance Complies with EMC directive 89/336/EEC (ISM 1B). Warranty Period One year Software Driver: *VXIPlug&Play *IntuiLink Connectivity Software Application Notes: The new and improved 66319B/D and 66321B/D high performance models are recommended for new automated test system platforms and for R&D applications. The 66309B/D and the 66311B are available for those customers who need to replicate existing test platforms and who do not want to re-engineer existing automated test system designs. Mobile Communications Device Testing (AN 1310) 5968-2424EN Using Battery Drain Analysis to Improve Mobile-Device Operating Time 5988-7772EN Evaluating Battery Run-down Performance Using the Agilent 66319D or 66321D with Option #053 14565A Device Characterization Software (AN 1427) 5988-8157EN Current Drain Analysis Enhances WLAN Network Card Design and Test (AN 1468) 5989-0565EN More detailed specifications at www.agilent.com/find/66300 83 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 40-100 W (Continued) Accessories Ordering Information Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 230 207 to 253 Vac, 47 to 63 Hz Opt 004 Make "Hi Compensation Mode" as default setting Opt 020 Front-panel Binding Posts (66332A only) Opt UJ0 No front panel binding posts (66332A only) Opt 053 Add 14565A Device Characterization Software with Battery Drain Analysis (66319B/D, 66321B/D) Opt 521 Solid State Relays (66309B/D, 66319B/D) Opt AYK No Solid State Relays (66309B/D,66319B/D) Opt 760 Isolation and Reversal Relays (66332A only) Opt 8ZJ Delete feet Opt 8ZL Include feet * Opt 1CM Rack-mount kit 66309B/D, 66311B, 66319B/D, 66321B/D: p/n 5062-3972; 66332A: p/n 5062-1912 * Opt 1CP Rack-mount Kit with Handles, p/n 5062-3975 (66332A only) * Opt AXS Rack-mount Kit for side-by-side mounting, (N/A for 66332A) Locking Kit p/n 5061-9694; Flange Kit p/n 5062-3974 Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service manual p/n 1494-0060 Rack Slide Kit (66332A only) E3663AC Support rails for Agilent rack cabinets 14565A Device Characterization Software with Battery Drain Analysis Note: Battery Drain Analysis means Data Logging and CCDF measurements. These capabilities require models 66319B, 66319D, 66321B or 66321D with version A.03.00 firmware or higher and 14565A software version 3.01 or higher. *Support rails required Agilent Models: 66309B/D, 66311B/D, 66319B/D, 66321B/D Top 425.8mm 16.8" 212.8mm 8.4" 88.1mm 3.5" 88.1 3. Rear 435mm 17.13" Side More detailed specifications at www.agilent.com/find/66300 84 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 40-100 W (Continued) Agilent Models: 666332A Top 364.4mm 14.3" Terminal Strip Detail Output 2 & 3 +S + - -S Screw Size: M35 x 0.6 88.1mm 3.5" 100mm 3.93" 425.4mm 16.75" Side Rear More detailed specifications at www.agilent.com/find/66300 85 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources 14565A Device Characterization Software Ideal for testing wireless and battery powered devices Converts Mobile Communications DC Source into a powerful bench top tool for R&D and Repair Easy-to-use Graphical User Interface and analysis tools No programming required Simplify test and analysis in R&D or on the repair bench With the Agilent 14565A Device Characterization Software, testing, analyzing, and troubleshooting wireless and battery powered devices is made simple. The 14565A provides a graphical user interface that lets you easily control the Mobile Communications DC Sources. It gives you access to the Mobile Communications DC Source's highpowered measurement system and provides an oscilloscope-like view of the voltage or current waveforms of the device under test. The 14565A provides reference waveform save/ recall, and provides oscilloscope-like measurement and analysis including voltage and current waveform parameter measurements, triggering, markers, zoom control, and more. By using the advanced capabilities built into the power supply, you can spend more time testing and analyzing instead of configuring and reconfiguring multiple pieces of test equipment, such as a current shunt, oscilloscope, current probe, DMM, and datalogger. (Continued) Waveform Capture Mode Zoom capability Power Supply output control Oscilloscope-like view of battery current profiles Measurement setup control * * * * Peak current Talk-mode Standby-mode Off-mode Calculated measurements Markers for fast analysts Data Logging Mode More detailed specifications at www.agilent.com/find/14565A 86 Application Specific DC Power Supplies tailored solutions for specific needs Mobile Communications DC Sources Device Characterization Software (Continued) When coupled with the 66319B/D or the 66321B/D, the 14565A also provides Battery Drain Analysis capabilities. More than just measuring battery run time, Battery Drain Analysis allows you to characterize current out of the battery and make tradeoffs in design that impact the current drain and battery life. This new version of the 14565A includes the measurement and data reduction tools needed to analyze and visualize the current being drained from your battery. By providing CCDF measurements and long-term battery drain data logging, the 14565A and 66319/21 provide a complete solution for analyzing current drain so that you can optimize your device designs to achieve maximum battery run time. Key features For Repair * Compact design with multiple instrument functionality * Fast and easy test setup * Graphical user software, no programming required * Dual DC outputs for replacing the main battery and the power adapter/charger power source * Electronic load for testing the battery charger circuitry * Programmable soft limits to protect against incorrect voltage settings Ordering Information 14565A Device Characterization Software with Battery Drain Analysis Note: Battery Drain Analysis means Data Logging and CCDF measurements. These capabilities require models 66319B, 66319D, 66321B or 66321D with version A.03.00 firmware or higher and 14565A software version 3.01 or higher. For R&D * Fast and easy test setup * Digitize current waveforms * Accurately log battery current drain measurements from 10 seconds to 1000 hours at 64,000 measurements per second * Test designs simulating different battery conditions with programmable output resistance * Zoom capability for analyzing waveform anomalies * Adjust markers for fast measurements on digitized waveforms * Easily document your test results * Record test data to files for archive or analysis by other software packages More detailed specifications at www.agilent.com/find/14565A 87 Application Specific DC Power Supplies tailored solutions for specific needs Solar Array Simulators Fast and accurate simulation of any type of solar array Multiple simulation modes Fast recovery time E4350B, E4351B Easy to simulate environmental conditions Specifications E4350B E4351B (at 0 to 55 C unless otherwise specified) The Agilent one-box Solar Array Simulator (SAS) is a DC power source that simulates the output characteristics of a solar array. The SAS is primarily a current source with very low output capacitance and is capable of simulating the I-V curve of different arrays under different conditions (i.e., temperature, age etc.). The I-V curve is programmable over the IEEE-488.2 bus and is conveniently generated within the SAS. The SAS provides three current operating modes: 2. Table Mode: For a fast and accurate I-V simulation, the SAS provides a table mode. The I-V curve is set by a user-defined table of points. A table can have any length up to 4000 points (a point corresponds to a specific value of I and V). As many as 30 tables may be stored in each of the SAS built-in volatile and non-volatile memory. E4350BJ02 Special Order Option Special Order Option Number of outputs 1 1 1 1 GPIB Yes Yes Yes Yes Output ratings (Simulator and Table Modes) Max. Power 480 W 480 W 480 W 480 W Voc. Max. 65 V 130 V 54 V 86.6 V Isc. Max. 8A 4A 9.6 A 6A Output ratings (for mixed mode) Max Power 480 W 480 W 480 W 480 W V rated 0-60 V 0-120 V 0-50 V 0-80 V I rated 0-8 A 0-4 A 0-9.6 A 0-6 A 0.075% + 10 mV 0.075% + 20 mV 0.075% + 8.5 mV 0.075% + 13.5 mV 0.2% + 10 mA 0.2% + 25 mA 0.2% + 15 mA Programming accuracy at 25C 5C Voltage (Fixed Mode) Current (Simulator and Fixed Mode) 0.2% + 20 mA 1. Simulator Mode: An internal algorithm is used to approximate a SAS I-V curve. Four input parameters: Voc (open circuit voltage), Isc (short circuit current), Imp and Vmp (current and voltage at the peak power point on the curve) are needed to establish a curve in this mode. E4350BJ01 Ripple and noise from 20 Hz to 20 MHz Voltage rms 16 mV 24 mV 16 mV 21 mV Voltage p-p 125 mV 195 mV 125 mV 175 mV Current rms 4 mA 4 mA 4 mA 4 mA Simulator Mode Fixed Mode I I I ac I mp Pmax Vmp Voo I rated V Pmax Vrated V More detailed specifications at www.agilent.com/find/E4350 88 Application Specific DC Power Supplies tailored solutions for specific needs Solar Array Simulators (Continued) Specifications E4350BJ03 E4350BJ04 E4350BJ06 Special Order Option Special Order Option Special Order Option Number of outputs 1 1 1 GPIB Yes Yes Yes (at 0 to 55 C unless otherwise specified) Non-volatile memory can store a maximum of 3500 points. The tables (I-V curves) are easily stored and recalled with an IEEE-488.2 command. The table(s) stored in this memory will be retained when the power is turned off. Volatile memory greatly increases the flexibility by saving up to 30,000 points. Multiple tables are easily accessed with IEEE-488.2 command. These tables will be erased after power is removed. Output ratings (Simulator and Table Modes) Max. Power 480 W 480 W 480 W Voc. Max. 52 V 47 V 74 V Isc. Max. 10 A 11 A 7A Output ratings (for mixed mode) Max Power 480 W 480 W 480 W V rated 0 - 48 V 0 - 43.5 V 0 - 68 V I rated 0.10 A 0 - 10 A 0-7A 0.075% + 8 mV 0.075% + 8 mV 0.075% + 11.5 mV Current (Simulator and Fixed Mode) 0.2% + 27.5 mA 0.2% + 30.5 mA 0.2% + 17.5 mA Programming accuracy at 25C 5C Voltage (Fixed Mode) Ripple and noise In Table Mode, current and voltage offsets can be applied to the selected table to simulate a change in the operating conditions of the solar array. 3. Fixed Mode: This is the default mode when the unit is powered on. The unit has the rectangular I-V characteristics of a standard power supply, when an output capacitor is added in this mode. Application Notes: Sequential Shunt Regulation (AN 1293) 5965-7329E Modern Connectivity Using USB and LAN I/O Converters (AN 1475-1) 5989-0123EN from 20 Hz to 20 MHz Voltage rms 16 mV 16 mV 19 mV Voltage p-p 125 mV 125 mV 150 mV Current rms 5.5 mA 6.5 mA 4 mA Supplemental Characteristics for all model numbers Load Switching Recovery Time: < 5 s when switched from short circuit to variable load, to within 1.5 A of an operating point on the I-V curve. Remote Sensing: Up to 2 V+ (Voc-Vmp). Add 3 mV to the voltage load regulation specification for each 1 volt change in the positive output lead due to load current change. Analog Programming of Output Current Input Signal: 0 to -4.0 V Input Impedance: 20 k Ohms nominal Shunt Regulation: Switching frequency up to 50 kHz Series Regulation: Switching frequency up to 50 kHz OVP and OCP: Overvoltage and overcurrent protection triggers in 100 us Capacitive Load: In fixed mode, the maximum load capacitance (without causing instability) is 2000 uF. In simulator and table mode, it is unconditionally stable at all capacitive loads. Inductive Load: The maximum load inductance (without causing instability) is 200 H Software Driver: VXIPlug&Play Regulatory Compliance: Listed to UL3101, certified to CSA 22.2 No. 1010.1, complies with EN 61010-1. RFI Suppression: Complies with CISPR-11, Group 1, Class A Size: 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.25 in x 19.6 in) Weight: Net, 25 kg (54 lb); shipping, 28 kg (61 lb) Warranty: One year More detailed specifications at www.agilent.com/find/E4350 89 Application Specific DC Power Supplies tailored solutions for specific needs Solar Array Simulators (Continued) Ordering Information Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz Opt 240 209 to 250 Vac, 47 to 63 Hz * Opt 908 Rackmount Kit, p/n 5062-3977 * Opt 909 Rackmount Kit with Handles, p/n 5063-9221 Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Accessories p/n 1252-3698 p/n 1252-1488 p/n 5080-2148 2 m (6.6 ft) p/n 1494-0059 7-pin Analog Plug 4-pin Digital Plug Serial Link Cable Accessory Slide Kit Agilent Models: E4350B, E4351B Top 497.8mm 19.6" Rear Output + - Vdc Max + - IP VP IM IM+P S S + - + - 425.5mm 16.75" Metric Pan Head, M4 x 0.7 x 8 mm long (center to center on these two screws is 20 mm, typ) Terminal Screw Size: 6-32 x 5/16in 518.2mm 20.4" 128mm 5.04" Rear 12.7mm 0.5" 132.6mm 5.2" Side More detailed specifications at www.agilent.com/find/E4350 90 145.1mm 5.71" DC Electronic Loads... maximize thoughput with real life loading conditions Agilent DC Electronic Loads provide solutions for the problems of testing DC power sources. Multiple Input Electronic Loads The Agilent N3300A series of DC electronic loads has been optimized for the needs of high volume manufacturing test. Test throughput is maximized with both faster speed and specialized programming and measurement capabilities. The accuracy is enhanced over previous Agilent electronic loads, to meet the needs of testing today's smaller power supplies. Single Input Electronic Loads The 6060B and 6063B are single input DC electronic loads. They are convenient for testing of one single output DC power supply. They provide a total solution, with built-in measurement functions. However, to maximize either speed or accuracy, the N3300A Series electronic loads are recommended. More detailed specifications at www.agilent.com/find/power 91 DC Electronic Loads maximize throughput with real-life loading conditions Multiple-Input 150 W to 600 W Standard DC connectors N3300A-N3307A Option UJ1 8 mm screw connectors Decrease system development time Lower cost of ownership Increase system reliability Increase test system throughput Increase system flexibility Stable operation down to zero volts DC connection terminal for ATE applications Increase Test Throughput Today's high volume manufacturing requires optimization of test system throughput, to maximize production volume without increasing floorspace. The N3300A Series electronic loads can help you in a number of ways to achieve this goal. Reduced command processing time: Commands are processed more than 10 times faster than previous electronic loads. Automatically execute stored command sequences: "Lists" of downloaded command sequences can execute independent of the computer, greatly reducing the electronic load command processing time and computer interaction time during product testing. Programmable delay allows for either simultaneous or sequential load changes: This is the most efficient way to conduct testing of multiple output DC power supplies, simulating real-life loading patterns, with a minimum of programming commands. Buffer measurement data: Voltage, current, and power measurements can be buffered for later readback to the computer, reducing computer interaction. Control measurement speed vs. accuracy: Decrease the number of measurement samples to achieve greater measurement speed, or increase the number of samples to achieve higher measurement accuracy. You can optimize your measurements for each test. region below one volt. When designing power supply test platforms, the trend towards lower voltage requirements should be taken into account. Refer to the specification and supplemental characteristic tables for details of lower voltage operating characteristics. Control rising and falling slew rates separately: Reduce rate of loading change when necessary for DUT stability or to simulate real life conditions, but otherwise change load values at maximum rate. Choose DC load connection method: Automatic test systems need consistency and reliability. Option UJ1 8 mm screw connectors provide a simple screw onto which your wires, terminated with insulated ring terminals, may be securely mounted. This optional connector is specifically designed for test systems. Wires may exit the plastic cover in any direction, and multiple wires may be placed on each screw terminal for easy parallel load connections. Up to AWG 4 wire may be used. Increase System Flexibility... for both present and future requirements Most power supply and battery charger test systems designed today need to test a variety of products and/or assemblies. In the future, additional products or assemblies may be needed. A flexible family of electronic loads makes present system design and future growth much easier. Test low voltage power supplies: The N3300A series electronic loads operate with full stability down to zero volts. Many other electronic loads available today have been found to become unstable in the operating Applications which require repeated connections/disconections are better suited to the standard connector. The standard connector accepts an unterminated wire, and may be hand-tightened. This connector is specifically designed for bench applications and short-term automated tests. More detailed specifications at www.agilent.com/find/N3300 92 DC Electronic Loads maximize throughput with real-life loading conditions Multiple-Input: 150 W to 600 W (Continued) Design a system to test a variety of products: This series consists of 2 mainframes and 5 modules. The N3300A mainframe is full rack width. It has 6 slots. The N3301A mainframe is half rack width. It has 2 slots. Any assortment of the 5 different modules can be configured into these mainframes, up to the slot capacity. The N3302A (150 watts), N3303A (250 watts), N3307A (250 watts) and N3304A (300 watts) each require one slot. The N3305A (500 watts) and the N3306A (600 watts) each require 2 slots. The electronic load can be configured to supply exactly what you need now, and this modular design also allows for easy future reconfiguration. Test high current power supplies: Electronic load modules can be operated in parallel to provide addition current sinking capability. Control the electronic load how you want to: GPIB, RS232, and manual use of the front panel all provide complete control of these electronic loads. There are also analog programming and monitoring ports for those applications that utilize non-standard interfaces, require custom waveforms, or utilize process control signals. Custom waveforms can also be created by downloading a "List" of load parameters. In addition, there is a built-in transient generator, which operates in all modes. Quickly create powerful and consistent software: All Agilent Technologies electronic loads use the SCPI (Standard Commands for Programmable Instruments) command set. This makes learning the commands easy, because they are the same format as all other SCPI instruments. The resulting code is virtually selfdocumenting, and therefore easier to troubleshoot and modify in the future. Plug-n-Play drivers are also available to help you to integrate the loads into your standard software packages. Make Measurements Easily and Accurately The 16-bit voltage, current and power measurement system provides both accuracy and convenience. The alternative is using a dmm (digital multimeter) and MUX (multiplexer) along with a precision current shunt and a lot of extra wiring. Avoiding this complexity increases system reliability and makes the system easier to design and support. Current measurements in particular are more consistently accurate using the electronic load's internal system, because the wiring associated with an external precision current shunt may pick up noise. Measure with all load modules simultaneously: Testing multiple-output DC power supplies and DC-DC converters can be very time consuming if each output must be tested sequentially. If measurements are being made through a MUX using one DMM, this is what will happen. Using the built-in measurement capabilities of the N3300A electronic loads, all outputs can be measured simultaneously. Alternatively, multiple single output power sources can be tested simultaneously. Measure voltage and current simultaneously: The N3300A measurement system has individual but linked current and voltage measurement systems. This means that voltage and current measurements are taken exactly simultaneously, which gives a true picture of the power supply under test's output at a particular moment in time. Some other electronic loads which feature internal measurement systems actually take current and voltage measurements sequentially, and therefore do not give as accurate a picture of momentary power. Observe transient behavior using waveform digitization: Transient response and other dynamic tests often require an oscilloscope. The N3300A has a flexible waveform digitizer with a 4096 data point buffer for voltage and a 4096 data point buffer for current. Under many circumstances, this internal digitizer will be adequate for power supply test needs. Current and voltage are digitized simultaneously, and the sampling rate and sample window are programmable. Some analysis functions are provided, including RMS, max and min. More detailed specifications at www.agilent.com/find/N3300 93 DC Electronic Loads maximize throughput with real-life loading conditions Multiple-Input: 150 W to 600 W (Continued) N3302A N3303A N3304A N3305A N3306A N3307A Table A-1 Specifications Table A-1 lists the specifications for the different load models. Specifications indicate warranted performance in the 25C 5C region of the operating temperature range. Specifications apply to normal and transient modes unless otherwise noted. Input Characteristic Operating Contour Voltage full scale Input ratings Current 0 - 30 A 0 - 10 A 0 - 60 A 0 - 60 A 0 - 120 A 0 - 30 A Voltage 0 - 60 V 0 - 240 V 0 - 60 V 0 - 150 V 0 - 60 V 0 - 150 V 150 W 250 W 300 W 500 W 600 W 250 W 2.0 V 30 A 10 A 60 A 60 A 120 A 30 A 1.5 V 22.5 A 7.5 A 45 A 45 A 90 A 22.5 A 1.0 V 15 A 5A 30 A 30 A 60 A 15 A 0.5 V 7.5 A 2.5 A 15 A 15 A 30 A 7.5 A 0V 0A 0A 0A 0A 0A 0A Typical minimum operating voltage @ full scale current Table A-1 states that maximum current is available down to 2 volts. Typically, however under normal operating conditions, the load can sink the maximum current down to the following voltages: Maximum Power @ 40C1 Specified current @ low voltage operation 1.2 V Max. Power Contour full scale Current Voltage full scale all specifiations apply 1 1.4 V 1.4 V 3 A/30 A 1 A/10 A 6 A/60 A 6 A/60 A 12 A/120 A 3 A/30 A 10 mA 8 mA 10 mA 10 mA 10 mA 10 mA 5 mA 4 mA 7.5 mA 7.5 mA 15 mA 7.5 mA 10 mA 7.5 mA 15 mA 15 mA 37.5 mA 15 mA 0.1% + High Range Accuracy 0.1% + Constant voltage mode2 Low Range/High Range 6 V/60 V 24 V/240 V 6 V/60 V 15 V/150 V 6 V/60 V 15 V/150 V Regulation 5 mV 10 mV 10 mV 20 mV 10 mV 10 mV 0.1% + 3 mV 10 mV 3 mV 10 mV 3 mV 10 mV High Range Accuracy 0.1% + 8 mV 40 mV 8 mV 20 mV 8 mV 20 mV Range 1 (I >10% of current rating) 0.067-4 0.2-48 0.033-2 0.033-5 0.017-1 0.067-10 Range 2 (I >1% of current rating) 3.6-40 44-480 1.8-20 4.5-50 0.9-10 9-100 Range 3 (I >0.1% of current rating) 36-400 440-4800 18-200 45-500 9-100 90-1000 Range 4 (I >0.01% of current rating) 360-2000 4400-12000 180-2000 450-2500 90-1000 900-2500 0.25 Hz10 kHz 0.25 Hz10 kHz 0.25 Hz 10 kHz 0.25 Hz10 kHz Constant resistance mode2 3 2 1.4 V Regulation Low Range Accuracy Derated Current Detail 1.2 V Low Range/High Range Low Range Accuracy 0 1.2 V Constant current mode2 slew rate limitations apply (see Table A-2) Transient generator 0 full scale Current Notes 1 Maximum continuous power available is derated linearly from 100% of maximum at 40C, to 75% of maximum at 55C. 2 Specification is (% of reading + fixed offset). Measurement is 1000 samples. Specification may degrade when the unit is subject to an RF field of 3 V/meter, the unit is subject to line spikes of 500 V, or an 8 kV electrostatic discharge. 3 DC current accuracy specifications apply 30 seconds after input current is applied. Frequency Range 0.25 Hz10 kHz 0.25 Hz10 kHz Pulse Width 50 s 1% to 50 s 1% to 50 s 1% to 50 s 1% to 50 s 1% to 50 s 1% to 4 seconds 1% 4 seconds 1% 4 seconds 1% 4 seconds 1% 4 seconds 1% 4 seconds 1% Current measurement2 Low Range/High Range 3 A/30 A 1 A/10 A 6 A/60 A 6 A/60 A 12 A/120 A 3 A/30 A Low Range Accuracy3 0.05% + 3 mA 2.5 mA 5 mA 5 mA 10 mA 3 mA 5 mA 10 mA 10 mA 20 mA 6 mA High Range Accuracy3 0.05% + 6 mA Voltage measurement2 Low Range/High Range 6 V/60 V 24 V/240 V 6 V/60 V 15 V/150 V 6 V/60 V 15 V/150 V Low Range Accuracy 0.05% + 3 mV 10 mV 3 mV 8 mV 3 mV 8 mV High Range Accuracy 0.05% + 8 mV 20 mV 8 mV 16 mV 8 mV 16 mV 0.5 W 1.2 W 0.5 W 1.5 W 1.2 W 0.5 W Power measurement2 Accuracy 0.1% + More detailed specifications at www.agilent.com/find/N3300 94 DC Electronic Loads maximize throughput with real-life loading conditions Multiple-Input: 150 W to 600 W (Continued) N3302A N3303A N3304A N3305A N3306A N3307A Table A-2 Supplemental Characteristics Programming Resolution Table A-2 lists the supplemental characteristics, which are not warranted but are descriptions of typical performance determined either by design or type testing. Constant current mode 0.05 mA/ 0.5 mA 0.02 mA/ 0.2 mA 0.1 mA/ 1 mA 0.1 mA/ 1 mA 0.2 mA/ 2 mA 0.05 mA/ 0.5 mA Constant voltage mode 0.1 mV/1 mV 0.4 mV/4 mV 0.1 mV/1 mV 0.25 mV/2.5 mV 0.1 mV/1 mV Constant resistance mode 0.07/0.7/ 7/70 m 0.82/8.2/ 82 m 0.035/0.35/ 3.5/35 m 0.085/0.85/ 8.5/85 m 0.0175/0.175/ 0.17/1.7/ 1.75/17.5 m 17/170 m Current 0.05 mA/ 0.5 mA 0.02 mA/ 0.2 mA 0.1 mA/ 1 mA 0.1 mA/ 1 mA 0.2 mA/ 2 mA 0.05 mA/ 0.5 mA Voltage 0.1 mV/ 1 mV 0.4 mV/ 4 mV 0.1 mV/ 1 mV 0.25 mV/ 2.5 mV 0.1 mV/ 1 mV 0.25 mV/ 2.5 mV Slow band 500 A/s 25 kA/s 167 A/s 8330 A/s 1 kA/s 50 kA/s 1 kA/s 50 kA/s 2 kA/s 100 kA/s 500 A/s 25 kA/s Fast band 3 V 50 kA/s 2.5 MA/s 16.7 kA/s - 100 kA/s 833 kA/s 5 MA/s 100 kA/s 5 MA/s 200 kA/s 10 MA/s 50 kA/s 2.5 MA/s Fast band <3 V 50 kA/s 250 kA/s 16.7 kA/s - 100 kA/s 83.3 kA/s 500 kA/s 100 kA/s 500 kA/s 200 kA/s 1 MA/s 50 kA/s 250 kA/s 1 kV/s 50 kV/s 4 kV/s 200 kV/s 1 kV/s 50 kV/s 2.5 kV/s 125 kV/s 1 kV/s 50 kV/s 2.5 kV/s 125 kV/s Fast band 3 V 100 kV/s 500 kV/s 400 kV/s 2 MV/s 100 kV/s 500 kV/s 250 kV/s 1.25 MV/s 100 kV/s 500 kV/s 250 kV/s 1.25 MV/s Fast band <3 V 100 kV/s 50 kV/s 400 kV/s 200 kV/s 100 kV/s 50 kV/s 250 kV/s 125 kV/s 100 kV/s 50 kV/s 250 kV/s 125 kV/s 44 /s 1125 /s 540 /s 13.5 k/s 22 /s 560 /s 55 /s 1400 /s 11 /s 280 /s 110 /s 2800 /s Fast band 3 V 2250 /s 34 k/s 27 k/s 408 k/s 1120 /s 17 k/s 2800 /s 42.5 k/s 560 /s 8.5 k/s 5600 /s 85 k/s Fast band <3 V 2250 /s 3.4 k/s 27 k/s 40.8 k/s 1120 /s 1.7 k/s 2800 /s 4.25 k/s 560 /s 850 /s 5600 /s 8.5 k/s 220 /s 5600 /s 550 /s 14 k/s 110 /s 2800 /s 1.1 k/s 28 k/s 0.25 mV/2.5 mV Readback resolution Notes 1 Slew rate bands are the ranges of programmable slew rates available. When you program a slew rate value outside the indicated bands, the electronic load will automatically adjust the slew rate to fit within the band that is closest to the programmed value. It is not necessary to specify the band, only the slew rate itself. Below 3 volts, the maximum bandwidth of the electronic load is reduced by a factor of ten to one. For example, in the current range for Model N3302A, the maximum slew rate is specified as 2.5 MA/s, below 3 volts the maximum slew rate would be 250 kA/s. Any slew rate programmed between 2.5 MA/s and 250 kA/s would produce a slew rate of 250 k/s. Slew rates programmed slower than 250 kA/s would still correctly reflect their programmed value. Note that if you are using transient mode to generate a high frequency pulse train, a reduced slew rate might cause the load to never reach the upper programmed value before beginning the transition to the lower programmed value. So even though the transient mode is still operational at lower voltages, a fast pulse train with large transitions may not be achievable. Programmable slew rate1 Current Ranges Voltage Ranges Slow band Resistance Range 1 Slow band Resistance Range 2 Slow band 440 /s 5.4 k/s 11.25 k/s 135 k/s Fast band 3 V 22.5 k/s - 270 k/s - 11.2 k/s - 28 k/s 340 k/s 4.08 M/s 170 k/s 425 k/s 5600 /s - 56 k/s 85 k/s 850 k/s Fast band <3 V 22.5 k/s - 270 k/s - 11.2 k/s - 28 k/s 34 k/s 408 k/s 17 k/s 42.5 k/s 5600 /s - 56 k/s 8.5 k/s 85 k/s 4.4 k/s - 54 k/s - 2.2 k/s 112.5 k/s 1.35 M/s 56 k/s 5.5 k/s 140 k/s 1.1 k/s 28 k/s 11 k/s 280 k/s Fast band 3 V 225 k/s 3.4 M/s 2.7 M/s - 112 k/s 40.8 M/s 1.7 M/s 280 k/s 4.25 M/s 56 k/s 850 k/s 560 k/s 8.5 M/s Fast band <3 V 225 k/s 340 k/s 2.7 M/s - 112 k/s 4.08 M/s 170 k/s 280 k/s 425 k/s 56 k/s 85 k/s 560 k/s 850 k/s 55 k/s 1.4 M/s 11 k/s 280 k/s 110 k/s 2.8 M/s Resistance Range 3 Slow band Resistance Range 4 Slow band 44 k/s 540 k/s - 22 k/s 1.125 M/s 13.5 M/s 560 k/s Fast band 3 V 2.25 M/s - 27 M/s 34 M/s 408 M/s 1.12 M/s - 2.8 M/s 17 M/s 42.5 M/s 560 k/s - 5.6 M/s 8.5 M/s 85 M/s Fast band <3 V 2.25 M/s - 27 M/s - 1.12 M/s - 2.8 M/s 3.4 M/s 40.8 M/s 1.7 M/s 4.25 M/s 560 k/s - 5.6 M/s 850 k/s 8.5 M/s More detailed specifications at www.agilent.com/find/N3300 95 DC Electronic Loads maximize throughput with real-life loading conditions Multiple-Input: 150 W to 600 W (Continued) N3302A N3303A N3304A N3305A N3306A N3307A Table A-2 (Continued) Supplemental Characteristics Programmable short Table A-2 lists the supplemental characteristics, which are not warranted but are descriptions of typical performance determined either by design or type testing. Programmable open 66 m max. 200 m max. 33 m max. 33 m max. 17 m max. 33 m max. 40 m typical 100 m typical 20 m typical 25 m typical 12 m typical 20 m typical 20 k 80 k 20 k 20 k 20 k 80 k Command processing time Using discrete commands 3 ms 3 ms 3 ms 3 ms 3 ms 3 ms Using List commands 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms Range 0 - 10 s 0 - 10 s 0 - 10 s 0 - 10 s 0 - 10 s 0 - 10 s Resolution 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms Accuracy 5 ms 5 ms 5 ms 5 ms 5 ms 5 ms 20 ms 20 ms 20 ms 20 ms 20 ms 20 ms List dwell characteristics Notes 2 Applies to all ranges. Measurement time 1000 samples (default) (with specified (with specified (with specified (with specified (with specified (with specified measurement measurement measurement measurement measurement measurement accuracy) accuracy) accuracy) accuracy) accuracy) accuracy) 200 samples 100 samples 20 points <20 points 10 ms 10 ms (with <6% additional fixed offset) (with <6% (with <6% additional additional fixed offset) fixed offset) 10 ms 9 ms 9 ms (with <10% additional fixed offset) (with <10% (with <10% additional additional fixed offset) fixed offset) 7 ms 7 ms 7 ms 7 ms (with <30% additional fixed offset) (with <30% (with <30% additional additional fixed offset) fixed offset) (with <30% additional fixed offset) (with <30% (with <30% additional additional fixed offset) fixed offset) 7 ms 7 ms 7 ms 7 ms (with >30% additional fixed offset) (with >30% (with >30% additional additional fixed offset) fixed offset) (with >30% additional fixed offset) (with >30% (with >30% additional additional fixed offset) fixed offset) 9 ms 7 ms 7 ms 10 ms 10 ms (with <6% additional fixed offset) (with <6% (with <6% additional additional fixed offset) fixed offset) 10 ms 9 ms 9 ms (with <10% additional fixed offset) (with <10% (with <10% additional additional fixed offset) fixed offset) 9 ms 7 ms 7 ms Ripple and noise (20 Hz - 10 MHz) Current (rms/peak to peak) 2 mA/20 mA 1 mA/10 mA 4 mA/40 mA 4 mA/40 mA 6 mA/60 mA 2 mA/20 mA Voltage (rms) 5 mVrms 12 mVrms 6 mVrms 10 mVrms 8 mVrms 10 mVrms 0.5% + 48 mV 0.5% + 12 mV 0.5% + 30 mV 0.5% + 12 mV 0.5% + 30 mV Current Programming Accuracy2 0.25% + 4.5 mA 0.25% + 1.5 mA 0.25% + 9 mA 0.25% + 9 mA 0.25% + 18 mA 0.25% + 4.5 mA External analog programming Voltage Programming Accuracy2 0.5% + 12 mV External monitor ports Voltage Monitor Accuracy 0.25% + 12 mV 0.25% + 48 mV 0.25% + 12 mV 0.25% + 30 mV 0.25% + 12 mV 0.25% + 30 mV Current Monitor Accuracy 0.1% + 4.5 mA 0.1% + 1.5 mA 0.1% + 9 mA 0.1% + 9 mA 0.1% + 18 mA 0.1% + 4.5 mA More detailed specifications at www.agilent.com/find/N3300 96 DC Electronic Loads maximize throughput with real-life loading conditions Multiple-Input: 150 W to 600 W (Continued) N3300A N3301A 0C to 55C 0C to 55C Operating range 100 - 250 Vac 48 - 63 Hz 100 - 250 Vac 48 - 63 Hz Input Current 4.2 A @ 100 - 127 Vac 2.2 A @ 200 - 250 Vac 2.3 A @ 100 - 250 Vac Table A-3 Supplemental Characteristics Operating temperature range Input ratings Application Notes: Agilent AN 372-1 Power Supply Testing (AN 372-1) 5952-4190 Agilent AN 372-2 Battery Testing (AN 372-2) 5952-4191 Increasing DC Power Supply Test System Throughput with Agilent Technologies N3300A DC Electronic Loads 5980-0233E Agilent Zero Volt Electronic Load 5968-6360E Making Fuel Cell AC Impedance Measurements Utilizing Agilent N3300A Series Electronic Loads 5988-5358EN Input VA 440 VA 230 VA Inrush Current 38 A 18 A @ 115 Vac 36 A @ 230 Vac Supplemental Characteristics for all model numbers Remote Sensing: 5 V DC between sense and load input Analog Programming Bandwidth: 10 kHz (-3 db frequency) in CC mode only Digital/Trigger Inputs Vil = 0.9 V max at Iil = -1 mA Vih - 3.15 V min (pull-up resistor on input) Analog Programming Voltage: Voltage: 0 - 10 V Current: 0 - 10 V Digital/Trigger Outputs Vol = 0.72 V max at Iol = 1 mA Voh = 4.4 V min at Ioh = -20 A Analog Monitor Ports: Voltage: 0 - 10 V Current: 0 - 10 V Agilent Models: N3300A Top 624.8mm 24.6" 425.5mm 16.75" 177.8mm 7.0" 190.5mm 7.5" Rear 50.8mm 2.0" 12.7mm 0.5" Side More detailed specifications at www.agilent.com/find/N3300 97 DC Electronic Loads maximize throughput with real-life loading conditions Multiple-Input: 150 W to 600 W (Continued) Software Driver: VXIPlug&Play Ordering Information Net Weight: N3300A: 13.2 kg (29 lb); N3301A: 7.3 kg (16 lb); N3302A, N3303A or N3304A: 2.7 kg (6 lb); N3305A or N3306A: 4.6 kg (10 lb), N3307A 2.7 kg (6 lb) Opt. UJG: Standard finger twist connector Opt. UJ1: 8 mm screw terminal connector (available on all load modules N3302A-N3307A) Opt. 800: Rack-mount kit for two N3301A Mainframes mounted side-by-side (p/n 5061-9694 and 5062-3978). Opt. 908: Rack-mount kit (Two p/n 5062-3974C for a N3300A, or p/n 5062-3960 for one N3301A). For the N3301A, the kit includes a blank filler panel. Opt. 909: Rack-mount kit with handles for N3300A (Two p/n 5062-3975 and 5063-9219) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Shipping Weight: N3300A: 17 kg (38 lb); N3301A: 9.1 kg (20 lb) N3302A, N3303A, or N3304A: 4.1 kg (9 lb) N3305A or N3306A: 6.8 kg (15 lb), N3307A 4.1 kg (9 lb) Warranty: One year Agilent Models: N3301A Top 624.8mm 24.6" 213.4mm 8.4" 177.8mm 7.0" 190.5mm 7.5" Rear 50.8mm 2.0" 12.7mm 0.5" Side More detailed specifications at www.agilent.com/find/N3300 98 DC Electronic Loads maximize throughput with real-life loading conditions Single-Input 250 W to 300 W Cost-effective for single input applications 6060B and 6063B The 6060B and 6063B each provides one load input. This is more convenient for single input applications than a mainframe product. These electronic loads are particularly suited for the lab bench. Entering commands manually using the front panel keypad is simpler because the channel does not need to be specified, as in a mainframe configuration. The keypad entry is further simplified because these products do not have the downloadable LIST feature of the N3300A Series, which helps to maximize production throughput. Extensive protection is included to help protect your valuable prototypes under test. This includes overvoltage, overcurrent, overtemperature, overpower, and reverse polarity. These loads are suitable for manufacturing test systems where maximizing speed is not critical. They use industry standard SCPI instructions, and also have VXIPlug&Play drivers to simplify system design. For the greatest speed and accuracy in programming and measurement, see the N3300A Series of DC electronic loads. Convenient optional front panel input connection Specifications 6060B 6063B Amperes 0 to 60 A 0 to 10 A Volts 3 to 60 V 3 to 240 V Maximum power (at 40 C) 300 W 250 W Ranges 0 to 6 A, 0 to 60 A 0 to 1 A, 0 to 10 A Accuracy 0.1% 75 mA 0.15% 10 mA Regulation 10 mA 8 mA Constant current mode Constant voltage mode Accuracy 0.1% 50 mV 0.12% 120 mV Regulation (w/remote sense) 10 mV 10 mV Constant resistance mode 0.033 to 1.0 0.20 to 24.0 Ranges 1 to 1,000 10 to 10,000 24 to 10,000 240 to 50,000 Accuracy 1 : 0.8% 8 m (with 6 A at input) 1 K: 0.3% 8 mS (with 6 V at input) 10 K: 0.3% 8 mS (with 6 V at input) 24 : 0.8% 200 m (with 1 A at input) 10 K/: 0.3% 0.3 mS (with 24 V at input) 50 K: 0.3% 0.3 mS (with 24 V at input) Frequency range Accuracy 0.25 Hz to 10 kHz 3% 0.25 Hz to 10 kHz 3% Duty cycle range Accuracy 3 to 97% (0.25 Hz to 1 kHz) 6 to 94% (1 to 10 kHz) 6% of setting 2% 3 to 97% (0.25 Hz to 1 kHz) 6 to 94% (1 to 10 kHz) 6% of setting 2% Current level high range Accuracy 60-A range: 0.1% 350 mA 10-A range: 0.18% 50 mA Current level low range Accuracy 6-A range: 0.1% 80 mA 1-A range: 0.18% 13 mA Voltage level Voltage level accuracy 3 to 60 V 0.1% 300 mV 3 to 240 V 0.15% 1.1 V Current readback accuracy Voltage readback accuracy 0.05% 65 mA (0.05% + 45 mV) 0.12% 10 mA (0.1% + 150 mV) Ripple and noise (20-Hz to 10-MHz noise) Current Voltage 4 mA rms 40 mA peak-to-peak 6 mV rms 1 mA rms 10 mA peak-to-peak 6 mV rms Transient generator Readback specifications More detailed specifications at www.agilent.com/find/6060 99 DC Electronic Loads maximize throughput with real-life loading conditions Single-Input: 250 W to 300 W (Continued) Specifications 6060B Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying the product) Notes: 1. Operating temperature range is 0 to 55C. All specifications apply for 25C 5C, except as noted. 2. Maximum continuous power available is derated linearly from 40C to 75% of maximum at 55C. 3. DC current accuracy specifications apply 30 seconds after input is applied. 6063B Constant current mode 60-A range: 16 mA 10-A range: 2.6 mA Resolution 6-A range: 1.6 mA 1-A range: 0.26 mA Temperature coefficient 100 ppm/C 5 mA/C 150 ppm/C 1 mA/C Resolution 16 mV 64 mV Temperature coefficient 100 ppm/C 5 mV/C 120 ppm/C 10 mV/C Constant resistance mode Resolution 1 : 0.27 m 1 K: 0.27 mS 10 K: 0.027 mS 24 : 6 m 10 K: 0.011 mS 50 K: 0.001 mS Temperature coefficient 1 : 800 ppm/C 0.4 m/C 1 K: 300 ppm/C 0.6 mS/C 10 K: 300 ppm/C 0.6 mS/C 24 : 800 ppm/C 10 m/C 10 K: 300 ppm/C 0.03 mS/C 50 K: 300 ppm/C 0.03 mS/C Frequency range Resolution 0.25 Hz to 10 kHz 4% or less 0.25 Hz to 10 kHz 4% or less Duty cycle range Resolution 3 to 97% (0.25 Hz to 1 kHz) 6 to 94% (1 to 10 kHz) 4% 3 to 97% (0.25 Hz to 1 kHz) 6 to 94% (1 to 10 kHz) 4% Current level high range Resolution 60-A range: 260 mA 10-A range: 43 mA Current level low range Resolution 6-A range: 26 mA 1-A range: 4 mA Constant voltage mode Transient generator Current temperature coefficient 100 ppm/C 7 mA/C 180 ppm/C 1.2 mA/C Voltage level resolution 260 mV 1V Voltage temperature coefficient 150 ppm/C 5 mV/C 120 ppm/C 10 mV/C Programmable slew rate 60-A range: 1 A/ms to 5 A/s 6-A range: 0.1 A/ms to 0.5 A/s 10-A range: 0.17 A/ms to 0.83 A/s 1-A range: 17 A/ms to 83 A/ms Rise/fall time 12 s to 8 ms 16 s to 8 ms Analog programming bandwidth 10 kHz (-3 dB frequency) 10 kHz (-3 dB frequency) Analog programming accuracy Current (low range) 4.5% 75 mA 3% 8 mA Current (high range) 4.5% 250 mA 3% 20 mA Temperature coefficient 100 ppm/C 6 mA/C 150 ppm/C 1 mA/C Voltage 0.8% 200 mV 0.5% 150 mV Temperature coefficient 100 ppm/C 1 mV/C 120 ppm/C 10 mV/C Analog programming voltage 0 to 10 V 0 to 10 V Readback specifications 17 mA (via GPIB) 2.7 mA (via GPIB) Current readback resolution 20 mA (front panel) 10 mA (front panel) Temperature coefficient 50 ppm/C 5 mA/C 100 ppm/C 1 mA/C Voltage readback resolution 17 mV (via GPIB) 20 mV (front panel) 67 mV (via GPIB) 100 mV (front panel) Temperature coefficient 50 ppm/C 1.2 mV/C 100 ppm/C 8 mV/C More detailed specifications at www.agilent.com/find/6060 100 DC Electronic Loads maximize throughput with real-life loading conditions Single-Input: 250 W to 300 W (Continued) Notes: 1. Operating temperature range is 0 to 55C. All specifications apply for 25C 5C, except as noted. 2. Maximum continuous power available is derated linearly from 40C to 75% of maximum at 55C. 3. DC current accuracy specifications apply 30 seconds after input is applied. Specifications 6060B Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying the product) (Continued) 6063B Analog monitor accuracy Current monitor (0 to 10 V out) 4% 85 mA 3% 10 mA Temperature coefficient 50 ppm/C 6 mA/C 100 ppm/C 1 mA/C Voltage monitor 0.25% 40 mV 0.4% 240 mV Temperature coefficient 50 ppm/C 0.2 mV/C 70 ppm/C 1.2 mV/C Remote sensing 5-Vdc maximum between sense and load input 5-Vdc maximum between sense and load input Minimum operating voltage (at full rated current) 2 volts (1.2 V typical) 2 volts (1.2 V typical) Programmable short 0.033 (0.020 typical) 0.20 (0.10 typical) Programmable open (typical) 20 k 80 k Current 0.03% 10 mA 0.03% 15 mA Voltage 0.01% 10 mV 0.01% 20 mV DC isolation voltage 240 Vdc, between any input and chassis ground 240 Vdc, between any input and chassis ground Digital inputs VIL = 0.9 V max at IIL = -1 mA / VIH = 3.15 V min (pull-up resistor on input) VIL = 0.9 V max at IIL = -1 mA / VIH = 3.15 V min (pull-up resistor on input) Digital outputs VOL = 0.72 V max at IOL = 1 mA / VOH = 4.4 V min at IOH = -20 A VOL = 0.72 V max at IOL = 1 mA / VOH = 4.4 V min at IOH = -20 A Net weight (approx.) 6.12 kg (13.5 lb) 6.12 kg (13.5 lb) Shipping weight 8.16 kg (18 lb) 8.16 kg (18 lb) (0 to 10 V out) Drift (over 8-hour interval) More detailed specifications at www.agilent.com/find/6060 101 DC Electronic Loads maximize throughput with real-life loading conditions Single-Input: 250 W to 300 W (Continued) Application Notes: Agilent AN 372-1 Power Supply Testing (AN 372-1) 5952-4190 Agilent AN 372-2 Battery Testing (AN 372-2) 5952-4191 Pulsed Characterization of Power Semiconductors Using Electronic Loads (AN 1246) 5091-7636E Supplemental Characteristics for all model numbers Software Driver: VXIPlug&Play Weight: 6.12 kg (13.5 lb) net; 8.16 kg (18 lb) shipping Ordering Information Opt 020 Front Panel DC Input Connectors Opt 100 87 to 106 Vac, 47 to 66 Hz input (for Japan only) Opt 120 104-127 Vac, 47 to 66 Hz Opt 220 191 to 233 Vac, 47 to 66 Hz input Opt 240 209 to 250 Vac, 47 to 66 Hz input * Opt 908 Rack-mount Kit (p/n 5062-3974C) * Opt 909 Rack-mount Kit with Handles (p/n 5063-9219) Opt 0L1 Full documentation on CD-ROM, and printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 0B0 Full documentation on CD-ROM only Opt 0B3 Service Manual * Support rails required Size: 425.5 mm W x 88.1 mm H x 396 mm D (16.75 in x 3.5 in x 13.7 in ) Accessories E3663AC Support rails for Agilent rack cabinets Agilent Models: 6060B, 6063B Warranty: One year 28.6mm 1.1" Top 396mm 13.7" 34.9mm 1.4" 425.5mm 16.75" 41.3mm 1.7" 88.1mm 3.5" 101.6mm 16.75" Side Rear 50.8mm 2.0" 12.7mm 0.5" More detailed specifications at www.agilent.com/find/6060 102 AC Power Source/Analyzers... an integrated AC power solution Agilent AC Power Source/ Analyzers provide a complete AC test solution. As AC sources, they combine the capabilities of a power amplifier and an arbitrary waveform generator. This allows you to simulate normal waveforms and many types of distorted power waveforms. The built-in power analyzer combines the capabilities of a multimeter, oscilloscope, harmonic analyzer and power analyzer. These instruments may also be used to produce DC power, either alone or as a DC offset to an AC waveform. More detailed specifications at www.agilent.com/find/power 103 AC Power Source/Analyzers an integrated AC power solution AC Power Source/Analyzers 375-1750 VA Provides a complete AC and DC power and measurement solution Protect valuable DUTs with extensive protection features Easy to use Graphical User Interface (GUI) 6811B, 6812B, 6813B The Complete AC Power Test Solution Since your product will have to operate in the real world of unpredictable AC power, you need to design and verify its correct operation under a wide range of AC power inputs. Brownouts, dropouts, sags, and other irregularities are not unusual in many communities today. Agilent AC sources have the features needed to easily accomplish this test goal either in an R&D environment or on the manufacturing test floor. If you plan to sell your products in a worldwide market, you will also need to test them at the line voltages and frequencies that they will eventually operate at. There is also additional testing needed to meet regulatory requirements for sale into some countries. Agilent AC sources offer a complete solution for AC power testing, helping you to simplify this important task. These instruments combine the features of a power amplifier and arbitrary waveform generator to give you the ability to do all of the tests that you need. There are many standard preprogrammed waveforms, or you can use the transient generation system to simulate sophisticated and repeatable AC line disturbances. DC power can also be generated, either as a DC offset or as a pure DC signal. Powerful Built-in Measurement Capabilities Agilent AC sources have extensive 16-bit precision measurement capabilities which would normally require a number of complex measurement instruments, including a DMM (digital multimeter), oscilloscope, power analyzer, and harmonic analyzer. The precision measurements include: * rms, DC, AC + DC voltage and current * peak voltage and current * real, apparent, and reactive power * harmonic analysis of voltage and current waveforms providing amplitude and phase up to the 50th harmonic * THD (total harmonic distortion) * Triggered acquisition of digitized voltage and current Dual Power Analyzer Option 020 The powerful built-in power meter/ analyzer in Agilent AC sources provides everything that you need to make AC measurements at the AC input to your DUT. For many test scenarios, this is the extent of the AC analysis required. Some test scenarios, however, require AC measurements to be made at both the AC input and the AC output of the DUT. Option 020 provides an additional power analyzer, complete with a precision current shunt, which can be connected anywhere you need it. This second analyzer can even be used for tests where the AC source is not providing power, thus expanding the usefulness of this instrument to many more test configurations. The additional analyzer is equivalent in specifications and capabilities to the standard analyzer. Using the measurement capabilities of an Agilent AC source simplifies your test setups and helps you obtain accurate data quickly. More detailed specifications at www.agilent.com/find/6800 104 AC Power Source/Analyzers an integrated AC power solution AC Power Source/Analyzers: 375-1750 VA (Continued) Using the dual power analyzer option instead of an additional power analyzer instrument externally is more than just convenient. Measurements on all four measurement channels (AC source output voltage and current, and dual power analyzer voltage and current inputs) are inherently synchronized with the AC source output waveform. This precision would be difficult to achieve using separate measurement instruments. Examples Dual Power Analyzer Applications * Complete testing of uninterruptible power sources (UPS) * Efficiency testing of DC power supplies * Efficiency testing of AC power sources * Efficiency testing of transformers * Safety testing of transformers * Line disturbance and brownout testing of DC power supplies * Line disturbance and brownout testing of AC power sources * Sleep mode current monitoring * Independent power analyzer Sleep Mode Current Monitoring Many electronic products have power-saving or sleep modes. In this mode, the device draws only enough power to be able to recognize a "wake-up" signal, and then execute a smooth "wake-up". The power drawn in this mode is a critical parameter, and the ability to accurately monitor it is important. The accessory precision current shunt that is supplied with option 020 is mounted in such a way to make it easy for you to replace it with a precision resistor of your choice. By doing this, you can configure the system to accurately monitor extremely low currents. This provides an easy way for you to profile the current draw in all modes of your product's operation. Since Agilent 6811B-6813B AC sources produce DC power as well as AC power, portable battery operated products can also be tested with this configuration. UPS (uninterruptible power source) Testing The Dual Power Analyzer Option provides many important benefits for UPS testing. Since the key to correct UPS operation is having the output react properly to changes on the input, being able to monitor the output relative to the input simplifies testing. For example, commands are available to enable calculation of UPS transfer time, and the phase difference between the UPS input and output voltage. Agilent AC sources also have programmable output impedance, enabling the UPS designer to verify product stability over a wide range of AC line impedance. Free Graphical User Interface (GUI) When you need to run a variety of tests, study the results carefully, and then run more tests with slightly varied conditions, writing computer programs using the extensive SCPI command set may seem burdensome. This is when you should download the latest copy of the Free Agilent AC Source Graphical User Interface from www.agilent.com. The Agilent AC source GUI makes it quick and easy to set the output of your Agilent AC source, be it from a stored waveform or with a waveform that you create using your mouse. The GUI also allows you to see the output of the AC source in graphical form, save the results, or dump them directly into a Microsoft Excel file. Microsoft Excel Link The direct Excel link feature was recently added to meet the current needs of R&D engineers. It makes it easy to keep the results of many tests, and makes them easily retrievable. With it, the test records resulting from changing conditions can be kept in one place and easily compared. Access to raw data often helps in fully understanding test results. For example, small local peaks may not be evident in processed data. V, I and phase results from harmonic measurements are particularly susceptible to not showing the complete story in a graphical representation. More detailed specifications at www.agilent.com/find/6800 105 AC Power Source/Analyzers an integrated AC power solution AC Power Source/Analyzers: 375-1750 VA (Continued) Test Suite for Avionics Equipment Agilent AC sources are well suited for testing equipment intended for use in the avionics industry which operate at nominally 400 Hz. One of the special requirements that many manufacturers in this industry must concern themselves with is testing to meet RTCA DO-160 standards. These standards involve both AC and DC immunity tests. The Agilent AC source GUI includes a section devoted to these tests. By using this tool, you can quickly step through the required set-ups with confidence. Extensive protection to prevent load damage In addition to overcurrent, overvoltage, overpower and overtemperature protection, the 6800 series offers output disconnect relays and remote inhibit capability (quickly disabling the output of the AC source via a TTL signal) to protect the device under test. Development engineers and test professionals in a wide variety of industries use AC power source/analyzers. Here are a few examples: The 6800 series is backed by a threeyear warranty and Agilent's worldwide network of support and service centers. Avionics Instrumentation, ATE test stations Computer Products Computers, Monitors, Peripherals Application info Consumer Products The 6800 series can help you test and improve your products. You can easily perform: 1. Static testing-generating and measuring voltage, frequency, and line current for meeting worldwide specifications. 2. Dynamic testing-generating AC line transients for limit testing and design verification. 3. Specialty testing-measuring current harmonic content and creating custom AC power waveforms (such as a combined AC + DC signal to simulate a telephone ring). 4. Precompliance regulatory testing-measuring current harmonics, voltage fluctuations and flicker emissions and generating voltage and frequency disturbances and interharmonics to determine product immunity. Home appliances, Audio and video equipment, Heating/cooling controls Dual Power Analyzer Input (for V and I) Agilent AC Source with Dual Power Analyzer option (side view) AC in Electrical Products Relays, Transformers, Power components, Fire alarms Lighting Products Electronic ballasts, Compact flourescent bulbs, Timers Motors AC motors, Electronic controllers Power Products AC/DC adapters, AC/DC power supplies, PBX power supplies, Uninterruptible power supplies Telecom Products RF amplifiers, CATV devices, MUX's, routers, switches Agilent supplied cable (for V and I) Equipment Under Test Agilent supplied shunt output Shunt line AC Source output Load Microsoft Excel offers a wide variety of data manipulation and graphical capabilities that can help an engineer gain the fullest understanding from the test data. load AC line cables (customer supplied) Test configuration of efficiency measurement using an Agilent AC source with the 020 Dual Power Analyzer Option. More detailed specifications at www.agilent.com/find/6800 106 AC Power Source/Analyzers an integrated AC power solution AC Power Source/Analyzers: 375-1750 VA (Continued) AC Source Graphical User Interface Inrush Current Measurement Ringer Voltage (DC + AC) Generation Voltage Slew Control (Brownout) One cycle AC Mains Dropout User Defined Waveform: Noise with Spikes Testing of UPS Input and Output using Dual Power Analyzer Option 020 More detailed specifications at www.agilent.com/find/6800 107 AC Power Source/Analyzers an integrated AC power solution AC Power Source/Analyzers: 375-1750 VA (Continued) Specifications 6811B 6812B 6813B 1 1 1 Power 375 VA 750 VA 1750 VA rms voltage 300 V 300 V 300 V rms current 3.25 A 6.5 A 13 A Repetitive & non-repetitive peak current 40 A 40 A 80 A Crest factor 12 6 6 Load Power factor capability 0 to 1 0 to 1 0 to 1 DC power 285 W 575 W 1350 W DC voltage 425 V 425 V 425 V DC current 2.5 A 5.0 A 10.0 A Output frequency range1 DC; 45 Hz to 1 kHz DC; 45 Hz to 1 kHz DC; 45 Hz to 1 kHz Constant voltage ripple and noise (20 kHz to 10 MHz) -60 dB (relative to full scale) -60 dB (relative to full scale) -60 dB (relative to full scale) (at 0 to 55 C unless otherwise specified) Number of phases For a sine wave with a resistive load at 0 to 40 C, within an output frequency range of 45 Hz to 1000 Hz, and in AC coupled mode after a 30 minute warm-up unless otherwise noted. Notes: 1 Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a digitization rate of 250 seconds per point. Frequency content of the measured signal must be limited to 4 k Hz or less to avoid aliasing effects. Output ratings (Maximum) Line regulation (% of full scale) 0.1% 0.1% 0.1% Load regulation (% of full scale) 0.5% 0.5% 0.5% Maximum total harmonic distortion 0.25% at 50/60 Hz 1% worst case 45 to 1 kHz 0.25% at 50/60 Hz 1% worst case 45 to 1 kHz 0.25% at 50/60 Hz 1% worst case 45 to 1 kHz Programming accuracy (25 5C) RMS voltage (% of output + offset) 0.15% + 0.3 V (45 - 100Hz) 0.5% + 0.3 V (>100 - 500 Hz) 1% + 0.3 V (> 500 - 1000 Hz) 0.15% + 0.3 V (45 - 100Hz) 0.5% + 0.3 V (>100 - 500 Hz) 1% + 0.3 V (> 500 - 1000 Hz) 0.15% + 0.3 V (45 - 100Hz) 0.5% + 0.3 V (>100 - 500 Hz) 1% + 0.3 V (> 500 - 1000 Hz) DC voltage 0.1% + 0.5 V 0.1% + 0.5 V 0.5% + 0.3 V Frequency 0.01% + 10Hz 0.01% + 10Hz 0.01% + 10Hz More detailed specifications at www.agilent.com/find/6800 108 AC Power Source/Analyzers an integrated AC power solution AC Power Source/Analyzers: 375-1750 VA (Continued) Specifications 6811B 6812B 6813B (at 0 to 55 C unless otherwise specified) Measurement Accuracy For a sine wave with a resistive load at 0 to 40 C, within an output frequency range of 45 Hz to 1000 Hz, and in AC coupled mode after a 30 minute warm-up unless otherwise noted. Notes: 1 Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a digitization rate of 250 seconds per point. Frequency content of the measured signal must be limited to 4 k Hz or less to avoid aliasing effects. 2 Select low measurement range for improved accuracy (10:1) for lower power measurements. Rms. voltage (45 - 100 Hz) DC voltage (25C 55C) 0.03% + 100 mV1 0.03% + 100 mV1 0.03% + 100 mV1 1 1 0.05% + 150 mV1 0.05% + 150 mV RMS current (45 - 100 Hz) high range low range 0.05% + 150 mV 2 0.05% + 10 mA 0.05% + 1.5 mA 0.05% + 10 mA 0.05% + 1.5 mA 0.05% + 10 mA 0.05% + 1.5 mA Power (VA) (45-100 Hz)2 high range low range 0.1% + 1.5 VA + 12 mVA/V 0.1% + 1.5 VA + 1.2 mVA/V 0.1% + 1.5 VA + 12 mVA/V 0.1 % + 1.5 VA + 1.2 mVA/V 0.1% + 1.5 VA + 12 mVA/V 0.1% + 1.5 VA + 1.2 mVA/V Power (watts) (45-100 Hz)2 high range low range 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 1.2 mW/V 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 1.2 mW/V 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 1.2 mW/V Frequency 0.01% + 0.01 Hz 0.01% + 0.01 Hz 0.01% + 0.01 Hz Power factor 0.01 0.01 0.01 Current magnitude Fundamental Low range Harmonics 2-49 0.03% + 1.5 mA 0.03% + 1 mA + 0.2%/kHz 0.03% + 1.5 mA 0.03% + 1 mA + 0.2%/kHz 0.03% + 1.5 mA 0.03% + 1 mA + 0.2%/kHz Current magnitude Fundamental High range Harmonics 2-49 0.05% + 5 mA 0.05% + 3 mA + 0.2%/kHz 0.05% + 5 mA 0.05% + 3 mA + 0.2%/kHz 0.05% + 5 mA 0.05% + 3 mA + 0.2%/kHz Supplemental Characteristics (Non-warranted characteristics determined by design that are useful in applying the product) Average programming accuracy (% of output + offset) rms current 1.2% + 50 mA 1.2% + 50 mA 1.2% + 50 mA rms voltage 125 mV 125 mV 125 mV DC voltage 250 mV 250 mV 250 mV Overvoltage programming (OVP) 2 V peak 2 V peak 2 V peak rms current 2 mA 4 mA 4 mA peak current 12.5 mA 25 mA 25 mA output frequency 10 Hz 10 Hz 10 Hz phase N/A N/A N/A Average programming resolution More detailed specifications at www.agilent.com/find/6800 109 AC Power Source/Analyzers an integrated AC power solution AC Power Source/Analyzers: 375-1750 VA (Continued) Specifications 6811B 6812B 6813B (at 0 to 55 C unless otherwise specified) Supplemental Characteristics (Continued) For a sine wave with a resistive load at 0 to 40 C, within an output frequency range of 45 Hz to 1000 Hz, and in AC coupled mode after a 30 minute warm-up unless otherwise noted. (Non-warranted characteristics determined by design that are useful in applying the product) Average measurement resolution rms voltage 10 mV 10 mV 10 mV rms current 2 mA 2 mA 2 mA Programmable output impedance resistance 0-1 0-1 0-1 AC Input Ratings notes: inductance 20 h - 1 mh 20 h - 1 mh 20 h - 1 mh 1 Measured at low line 2 Measured at high line Remote sense capability Up to 1 Vrms can be dropped across each load lead. Up to 1 Vrms can be dropped across each load lead. Up to 1 Vrms can be dropped across each load lead. Isolation to ground 300 Vrms/425 Vdc 300 Vrms/425 Vdc 300 Vrms/425 Vdc Net weight 28.2 kg (62 lb) 28.2 kg (62 lb) 32.7 kg (72 lb) Shipping weight 31.8 kg (70 lb) 31.8 kg (70 lb) 36.4 kg (80 lb) Dimensions See drawings on page 105 Application Notes: Agilent 6800 Series AC Power Source/Analyzer 5963-7044E Testing Uninterruptible Power Supplies Using Agilent 6800 Series AC Power Source/Analyzers, 5967-6056E AC Input Ratings Voltage range (Vac) *default factory setting 87 to 106 Vac *104 to 127 Vac 174 to 220 Vac 191 to 254 Vac 174 to 220 Vac *191 to 254 Vac Simplify your Avionics Testing with a 400 Hz Single Phase Power Source that includes a Built-in 26 V reference signal 5989-3700EN 87 to 106 Vac *104 to 127 Vac 174 to 220 Vac 191 to 254 Vac Maximum input current (rms)1 28 A (100 Vac) 24 A (120 Vac) 15 A (200/208 Vac) 13 A (230 Vac) 22 A (200/208 Vac) Software Driver: VXIPlug&Play 12 A (100 Vac) 10 A (120 Vac) 7.5 A (200/208 Vac) 6.5 A (230 Vac) Input power (max)2 1000 VA/700 W 2500 VA/1400 W 3800 VA/2600 W Input frequency 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz 20 A (230 Vac) Warranty: One year More detailed specifications at www.agilent.com/find/6800 110 AC Power Source/Analyzers an integrated AC power solution AC Power Source/Analyzers: 375-1750 VA (Continued) Ordering Information Opt 019 2000 VA AC Power source/ analyzer (6813B only) Opt 020 Dual power analyzer option (6813B only) Opt 026 26 Volt, 0.1A auxiliary 45 to 100 Hz only reference output (6812B only) Opt 0B0 Full documentation on CD-ROM only Opt 0L1 Full documentation on CD-ROM, and/with printed standard documentation package Opt 0L2 Extra copy of standard printed documentation package Opt 1CM Rack-mount Kit, p/n 5062-3977 (quantity 2) (support rails required) Opt 1CP Rack-mount Kit with Handles, p/n 5062-3983 (support rails required) 6811B, 6812B, 6813B only Support rails, p/n 12679B, required when rack mounting the 6811B, 6812B, and 6813B Opt 1CM and Opt 1CP. E3664AC non Agilent rack. E3663AS for Agilent rack. Opt 120 104-127 Vac (120 Vac nominal), 47-63 Hz Opt 200 (6813B only) 174-220 Vac (200 Vac nominal), 47-63 Hz, Japan only Opt 208 (6811B and 6812B only) 174 to 220 Vac (208 Vac nominal), 47-63 Hz Opt 230 191 to 254 Vac (230 Vac nominal), 24-63 Hz Opt 831 12 AWG, 200 to 240 Vac, unterminated (6812B, 6813B only) Opt 832 4 mm2 wire size, unterminated (6813B only) Opt 833 1.5 mm2 wire size, 200 to 240 Vac, unterminated (6812B only) Opt 834 10 AWG, 100 to 120 Vac, unterminated (6812B only) Opt 841 Line Cord with NEMA L6-20P; 20 A 250 V Plug (6812B only) Opt 842 Line Cord with IEC 309; 32 A 220 V plug (6813B only) Opt 844 Line Cord with NEMA L6-30P; 30 A 250 V Locking Plug (6813B only) Opt 845 Line Cord with IEC 309; 16 A 220 V Plug (6812B only) Opt 846 Line Cord with NEMA L6-30P; 30 A 120 V Plug (6812B only) Opt 847 Line Cord with CEE 7/7; 16 A 220 V Plug (6812B only) Opt 848 Line Cord with BS 546; 15 A 240 V Plug (6812B only) See the AC line voltage and cord section, for more details on line cords. Agilent Models: 6811B, 6812B, 6813B Top 574.7mm 22.63" Opt 100 (6811B and 6812B only) 87 to 106 Vac (100 Vac nominal), 47-63 Hz, Japan only 425.5mm 16.75" 132.6mm 5.2" 128mm 5.04" Terminal Strip Screw Size: 6-32 Rear 50.8mm 2.0" 12.7mm 0.5" Side More detailed specifications at www.agilent.com/find/6800 111 Choosing AC Line Voltage and Cord Options for your Agilent Power Products DC Power Supplies, DC Electronic Loads, and AC Sources 4 Easy Steps for Choosing Line Cord Options Choosing AC Line Voltage and Cord Options for your Power Product Power distribution systems, regulations, and connection techniques vary greatly among geographic regions as a result of local AC electrical standards. Most Agilent products, including power products which draw less than 500 watts of power from the AC line, can be readily adjusted to accept different line voltages or frequencies. Step 1 Line voltage and frequency for certain Power Products may not be field changeable. Choosing the correct voltage option for these products requires care. This is especially true for higher power products. Line cords for high power products Go to the tables. Find the model number and the correct line cord option of the product you are ordering. Line cords for low power products Step 2 If your model # requires a 900 series line cord, the correct one will automatically be shipped for the destination country on the purchase order. DONE!cords for high power products Step 3 If your model number requires an 800 series line cord, determine if there is a line cord with plug that matches your outlet receptacle. If not, choose the appropriate unterminated line cord. Step 4 Add the option number for the appropriate line cord to your purchase order. DONE! For more detailed specifications see the product manual at www.agilent.com/find/power 112 Choosing AC Line Voltage and Cord Options for your Agilent Power Products DC Power Supplies, DC Electronic Loads, and AC Sources (Continued) Cord Options 900 901 902 903 904 Product/Family Low Power Products For lower power products, a universal receptacle on the rear panel accepts a wide range of line cords to meet local regulatory requirements. The tables containing the 900 series line cords show a range of standard line cords that Agilent offers, with option numbers and part numbers. E E E L N L N N L E L N E L N United Kingdom Australia New Zealand Europe Korea United States Canada United States Canada 6033A, 38A 8120-1351 8120-1369 8120-1689 8120-4383 8120-0698 6060B, 63B 8120-1351 8120-1369 8120-1689 8120-4383 8120-0698 6541A - 45A 8120-1351 8120-1369 8120-1689 8120-4383 8120-0698 Part numbers are needed to order a line cord separately. 6551A - 55A 8120-1351 8120-5412 8120-5413 8120-5337 8120-5421 6611C - 14C 8120-8705 8120-1369 8120-1689 8120-4383 8120-0698 For products which use the 900 series line cords, the appropriate type is automatically selected at time of shipment, based on the country to which the product is being shipped. If you plan to use your power products in a different country or region than the country to which the product is being shipped, you will need to specify the appropriate line voltage and line cord options on your order, so that we can provide the appropriate configuration. Contact your local Agilent Field Engineer for assistance. 6621A - 6629A 8120-1351 8120-1369 8120-1689 8120-4383 8120-0698 6631B - 34B 8120-8705 8120-1369 8120-1689 8120-4383 8120-0698 6641A - 45A 8120-1351 8120-1369 8120-1689 8120-4383 8120-0698 6651A - 55A 8120-1351 8120-5412 8120-5413 8120-5337 8120-5421 6811B 8120-1351 8120-5412 8120-1689 8120-5337 8120-5421 66309B/D 8120-8705 8120-1369 8120-1689 8120-4383 8120-0698 66311B 8120-8705 8120-1369 8120-1689 8120-4383 8120-0698 66319B/D 8120-8705 8120-1369 8120-1689 8120-4383 8120-0698 66321B/D 8120-8705 8120-1369 8120-1689 8120-4383 8120-0698 66332A 8120-8705 8120-1369 8120-1689 8120-4383 8120-0698 E3610 - 17A 8120-1351 8120-1369 8120-8768 8120-8767 8120-0698 E3620A 8120-1351 8120-1369 8120-8768 8120-8767 8120-0698 E3630A 8120-1351 8120-1369 8120-8768 8120-8767 8120-0698 E3631 - 34A 8120-1351 8120-1369 8120-8768 8120-8767 8120-0698 E3640 - 49A 8120-1351 8120-1369 8120-8768 8120-8767 8120-0698 E4350B, 51B 8120-1351 8120-5412 8120-5413 8120-5337 8120-5421 N5741A - 52A 8120-1351 N/A 8120-1689 8120-4383 N/A N6700B, N6701A - 02A N6710B, N6711A, 12A 8120-1351 8120-1369 8120-1689 8120-43831 8120-0698 N3300A, 31A 8120-1351 8120-1369 8120-1689 8120-4383 8120-0698 L = Line or Active Conductor (also called "live" or "hot") N = Neutral or identified Conductor E = Earth or Safety Ground 1 For models N6702A and N6712A: Using 100-120 Vac limits total output power to 600 W. 200-240 Vac line is required to permit full 1200 W operation For more detailed specifications see the product manual at www.agilent.com/find/power 113 Choosing AC Line Voltage and Cord Options for your Agilent Power Products DC Power Supplies, DC Electronic Loads, and AC Sources (Continued) Cord Options 906 912 917 918 919 Product/Family N E L N L E L N E E L N N L E Switzerland Denmark South Africa India Japan Israel 6033A, 38A 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 6060B, 63B 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 6541A - 45A 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 6551A - 55A 8120-2104 8120-2956 8120-5414 8120-5342 8120-6800 6611C - 14C 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 6621A - 6629A 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 6631B - 34B 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 6641A - 45A 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 6651A - 55A 8120-2104 8120-2956 8120-5414 8120-5342 8120-6800 6811B 8120-2104 8120-2956 8120-5414 8120-5342 8120-6800 66309B/D 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 66311B 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 66319B/D 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 66321B/D 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 66332A 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 E3610 - 17A 8120-2104 8120-2956 8120-4211 8120-4753 8120-5181 E3620A 8120-2104 8120-2956 8120-4211 8120-4753 8120-5181 E3630A 8120-2104 8120-2956 8120-4211 8120-4753 8120-5181 E3631 - 34A 8120-2104 8120-2956 8120-4211 8120-4753 8120-5181 E3640 - 49A 8120-2104 8120-2956 8120-4211 8120-4753 8120-5181 E4350B, 51B 8120-2104 8120-2956 8120-5414 8120-5342 8120-6800 N5741A - 52A N/A N/A N/A 8120-4753 N/A N6700B, N6701A - 02A N6710B, N6711A, 12A 8120-1351 8120-1369 8120-1689 8120-43831 8120-0698 N3300A, 31A 8120-2104 8120-2956 8120-4211 8120-4753 8120-6800 L = Line or Active Conductor (also called "live" or "hot") N = Neutral or identified Conductor E = Earth or Safety Ground 1 For models N6702A and N6712A: Using 100-120 Vac limits total output power to 600 W. 200-240 Vac line is required to permit full 1200 W operation For more detailed specifications see the product manual at www.agilent.com/find/power 114 Choosing AC Line Voltage and Cord Options for your Agilent Power Products DC Power Supplies, DC Electronic Loads, and AC Sources (Continued) Cord Options 920 921 922 927 Product/Family E N E L N E L N E L N L Argentina Chile China Brazil Thailand 6033A, 38A 8120-6869 8120-6980 8120-8376 8120-8871 6060B, 63B 8120-6869 8120-6980 8120-8376 8120-8871 6541A - 45A 8120-6869 8120-6980 8120-8376 8120-8871 6551A - 55A 8120-6869 8120-6980 8120-8376 8120-8871 6611C - 14C 8120-6869 8120-6980 8120-8376 8120-8871 6621A - 6629A 8120-6869 8120-6980 8120-8376 8120-8871 6631B - 34B 8120-6869 8120-6980 8120-8376 8120-8871 6641A - 45A 8120-6869 8120-6980 8120-8376 8120-8871 6651A - 55A 8120-6869 8120-6980 8120-8376 8120-8871 6811B 8120-6869 8120-6980 8120-8376 8120-8871 66309B/D 8120-6869 8120-6980 8120-8376 8120-8871 66311B 8120-6869 8120-6980 8120-8376 8120-8871 66319B/D 8120-6869 8120-6980 8120-8376 8120-8871 66321B/D 8120-6869 8120-6980 8120-8376 8120-8871 66332A 8120-6869 8120-6980 8120-8376 8120-8871 E3610 - 17A 8120-6869 8120-6980 8120-8376 8120-8871 E3620A 8120-6869 8120-6980 8120-8376 8120-8871 E3630A 8120-6869 8120-6980 8120-8376 8120-8871 E3631 - 34A 8120-6869 8120-6980 8120-8376 8120-8871 E3640 - 49A 8120-6869 8120-6980 8120-8376 8120-8871 E4350B, 51B 8120-6869 8120-6980 8120-8376 8120-8871 N5741A - 52A N/A N/A 8120-8376 N/A N6700B, N6701A - 02A N6710B, N6711A, 12A 8120-6869 8120-6980 8120-8376 8120-8871 N3300A, 31A 8120-6869 8120-6980 8120-8376 8120-8871 L = Line or Active Conductor (also called "live" or "hot") N = Neutral or identified Conductor E = Earth or Safety Ground For more detailed specifications see the product manual at www.agilent.com/find/power 115 Choosing AC Line Voltage and Cord Options for your Agilent Power Products DC Power Supplies, DC Electronic Loads, and AC Sources (Continued) Cord Options 831 832 833 834 No Plug #12AWG No Plug 4 mm2 No Plug 1.5mm2 No Plug #10AWG 6030A, 31A, 32A, 35A 8120-5573 N/A 8120-5568 8120-5566 6571A - 75A 8120-5488 8120-5490 N/A 8120-5545 6671A - 75A 8120-5488 8120-5490 N/A 8120-5545 6812B 8120-5573 N/A 8120-5568 8120-5566 6813B 8120-5573 8120-6502 N/A 8120-5566 66000A 8120-5573 N/A 8120-5568 8120-5566 E4356A 8120-5488 8120-5490 N/A 8120-5545 Cord Options 861 862 841 842 Product/Family High Power Products There are several factors which limit the amount of power which can be readily drawn from a normal branch circuit. For example, in the U.S., the typical 115/120 Vac branch circuit has a circuit breaker rated for 15 A. For industrial applications, 20 A service is commonly available. Linear power supplies with outputs over 500 watts and switching supplies rated over 750 watts will generally exceed the capability of a 15 A branch circuit. Connecting power products above these power levels will require installing either a higher voltage or higher current service. Some practical examples are: * standard line voltage for 2KW products such as the 667XA is 230 Vac; they can not be powered off a 120 Vac line * the 1KW 601XA and 603XA products cannot be powered off a standard 15 A/120 Vac circuit; they can operate off a 30 A/ 120 Vac service, or they can be configured for 208/240 Vac operation Agilent offers a range of 800 series line cords for many higher power products to mate with the wall receptacles commonly specified for these higher power services. Refer to the tables to determine if there is a 800 series line cord for your product with a plug that meets the local requirements. If not, you must order an unterminated line cord. Product/Family L N E L N E No Plug (AWG) N/S America, (AWG wire) No Plug (Metric) Asia, Europe, Harmonized (metric wire) NEMA 6-20P #12AWG N/S America Japan IEC 309 32-A 4mm2 Europe Korea 6030A, 31A, 32A, 35A N/A N/A 8120-5572 N/A 6571A - 75A N/A N/A N/A 8120-5489 6671A - 75A N/A N/A N/A 8120-5489 6680A - 84A 8121-6203 8120-6204 N/A N/A 6690A - 92A 8121-0694 8121-0695 N/A N/A 6812B N/A N/A 8120-5572 N/A 6813B N/A N/A N/A 8120-6506 66000A N/A N/A 8120-5572 N/A E4356A N/A N/A N/A 8120-5489 N5761A-72A 8121-1330 8121-1331 N/A N/A Often, higher power products (over 1 kW) are hardwired, i.e. connected directly to a breaker panel or distribution box. The line cord may also be hard wired to the back of the power supply where a universal receptacle is impractical. Typically, a local electrician should be consulted to determine the best alternative to connect a high power product to the AC line. For more detailed specifications see the product manual at www.agilent.com/find/power 116 Choosing AC Line Voltage and Cord Options for your Agilent Power Products DC Power Supplies, DC Electronic Loads, and AC Sources (Continued) Cord Options 844 845 846 847 848 Product/Family Y L N X W E G L Delta E E G N L L N NEMA L6-30P #10AWG N/S America Japan IEC 309 16-A 1.5 mm2 Denmark Switzerland Austria, China NEMA L5-30P #10AWG N. America CEE 7/7 16-A 1.5 mm2 Europe Korea BS 546 15-A 1.5 mm2 India South Africa 6030A, 31A, 32A, 35A N/A 8120-5570 8120-5565 8120-5567 8120-5569 6571A - 75A 8120-5546 N/A N/A N/A N/A 6671A - 75A 8120-5546 N/A N/A N/A N/A 6812B N/A 8120-5570 8120-5565 8120-5567 8120-5569 6813B 8120-6507 N/A N/A N/A N/A 66000A N/A 8120-5570 8120-5565 8120-5567 8120-5569 E4356A 8120-5546 N/A N/A N/A N/A V (line-to-line) OC OB OA Earth Gnd These are the ONLY connections used when powering the 668XA and 669XA Wye Neutral V (never used) (line-to-line) V (line-to-neutral) In a wye system V(line-to-neutral) = V(line-to-line) 3 Note: The countries or regions indicated here are for general guidance only. Local electrical codes governing wire size, wire type (AWG or metric) and plug type should be consulted to determine which of these available line cords/plugs is correct in your country to make proper connection to your AC mains. Please consult a qualified, licensed electrician for more information. Products with 3-Phase Inputs Some of the higher power products exceed the capability of a single phase line. Agilent offers several power products which require 3-phase inputs, including the 5 kW 668XA and 6.6 kW 669XA DC source family. For 3-phase power distribution up to the building, there are two different distribution systems in wide use: delta, predominantly used in the US; and wye predominantly used in Europe. However, for service inside the building, the 5 wire wye is the predominant configuration. Products which are delta loads, are compatible with either delta or wye. Agilent 3-phase products are delta loads. In selecting the correct operating voltage for 3-phase products you need to distinguish between the line-to-line and the line-to-neutral voltages. The line-to-line voltage is the square root of 3 x the line-toneutral voltage. It is the line-to-line voltage that is used to specify the input voltage to be applied to Agilent power products. For more detailed specifications see the product manual at www.agilent.com/find/power 117 Power Products Applications Information 10 Most frequently asked questions about using DC power products AC Power and Load Connections Power Products Terms 10 Most frequently asked questions about using DC power products 1 2 How do I put the power supply in the constant current mode? I have 208 vac, 3 phase power; can it be used to operate a product requiring 208 V single phase? The power supply cannot be "put" into the constant current mode. The output settings of the power supply combined with the ohmic value of the particular load determine whether or not the power supply is in constant current. ie: The power supply inherently resides in the constant voltage mode. If the output voltage were set to 24 volts and a 6 load were placed across the output terminals, Ohm's Law would require that 4 amps would flow (24 V/6 ). This presumes that the constant current setting of the power supply were set to a value greater than 4 amps; lets say 5 amps. Now, if the 6 load were replaced by a 2 load, Ohm's Law would suggest that 12 amps (24 V/ 2 ) would flow. However, the power supply is set to go into constant current at 5 amps. Therefore, the actual output voltage would be 10 volts (2 x 5 A). The power supply will now remain in constant current for values of load = 0 R < 4.8 . Once the ohmic value of the load becomes greater than 4.8 (24 V/5 A), the power supply will again revert to constant voltage operation at the value of 24 volts. Yes, see below. 657xA/667xA Connection to a 3-phase line B Phase A Phase Earth (Safety Ground) 120 Volts (Typ) C Phase 208 Volts (Typ) N L Note: Connections are made from phase to phase. Assume V (nominal) = 208 Vac 208V @ 8% low = 191V 208V @ 12% high = 233V (Instrument operates between 191 & 250 Vac) instrument will not operate on a 120 Vac line Rear of Instrument Instrument requires an ac input voltage in the window 191-250 Vac 3 Why are the required Watts and VA so different? Watts is a scalar quantity which is frequently used to measure system efficiency. It is the energy supplied by the utility company over a given period of time and is commonly referred to as power. Except for heavy industrial users, the utility company only bills users for the watts consumed. Watts are directly convertible into mechanical work or BTUs (British Thermal Units) of heat. Wasted power is paid for a second time in terms of additional loading on the user's air-conditioning system. Mathematically, it is a scalar quantity resulting from the vector product of two vector quantities (volts and amps). It is NOT the simple algebraic product of the rms volts times rms current. VA on the other hand IS the scalar quantity resulting from multiplying the magnitudes (rms) of the vector More detailed specifications at www.agilent.com/find/power 118 10 Most frequently asked questions about using Applications Information DC power products (Continued) Power Products quantities (volts and amps). This resulting quantity will never be smaller than the watts demanded by an instrument. Uninformed users incorrectly use VA to assess the device's over-all efficiency and power demands. VA is most frequently and correctly used by electricians to determine proper AC mains conductor gage and circuit breaker sizing. 4 How much cooling do I need for my power supply? Users frequently rack power supplies into an enclosure to supply power to some remotely located external load. Under these conditions, to properly determine the cooling requirements, the systems integrator needs thermal data from the manufacturer for the specific enclosure in question. This data is generally in the form of a curve which relates the rise of the enclosure's internal air temperature to the amount of power (or BTU's) dissipated within the enclosure. The difference between the maximum power demanded by the external load, and the AC power demanded by the power supply to support the load's needs, is the power dumped into the internal air of the enclosure. Using this number and data for the enclosure, the internal rise can be determined. The internal rise added to the external ambient temperature will determine the temperature of the environment for the power supply. This must be within the ratings of the product or premature failure will occur. A valuable conversion factor between Watts and BTU's is listed below: 1 BTU/Hr = 0.293 Watt The N57xxA family draws cooling air from the outside of the rack. Thus, the air temperature is equal to that of the room's environment. Heated, cooling air is then exhausted into the inside of the rack. As a result, these instruments will not properly cool if the inside of the rack is "pressurized". The static air pressure within the rack must be equal to or less than the air pressure in the room's ambient. The value of the sink current is fixed and is not programmable, with the exception of the 6630 series, where sink current is set to the same value that is programmed for source current. In general, sinking is provided to improve a power supply's transition time from a higher to a lower constant voltage operating level, and is not intended to be a steady-state operating condition. Other models not listed here do not have high powered down programmers. Instead, they are capable of discharging the power supply output capacitors but not sinking current from the device under test. Series Current Sinking Capability 5 6620 Multiple Output 110% of source current rating Can Agilent power supplies sink current? 6630 100 Watt 110% of source current rating 6030 Autorangers 50 W/actual output voltage in volts or actual voltage in volts/0.05 ohms, whichever is less 6640 200 Watt 25% of source current rating 6650 500 Watt 20% of source current rating 6750/6760 50/100 Watt Dynamically controlled to maximize output downprogramming speed. 7 W continuous dissipation, 300 W peak. Yes! Sinking, or downprogramming, is the ability of a power supply to pull current into the positive power terminal. Sinking is necessary to discharge the power supply's own output capacitor, or the capacitors that are part of an external load. Sinking is particularly important, for example, in printed circuit board test systems. The relays in test board systems typically must be switched only when the power supplies have discharged to zero volts, to avoid arcing and burn-out of the relay contacts. Sinking allows the power supply outputs to go to zero quickly, thus providing faster test times, an important factor for reducing overall test cost. More detailed specifications at www.agilent.com/find/power 119 10 Most frequently asked questions about using Applications Information DC power products (Continued) Power Products Series Current Sinking Capability 6670 2000 Watt 50 W/actual output voltage in volts or actual output voltage in volts/ 0.05 ohms, whichever is less 6680 5000 Watt 50 W/actual output voltage in volts or actual output voltage in volts/0.05 ohms, whichever is less 7 Can I use Agilent Electronic Loads in series and in parallel? Agilent electronic loads are designed to be operated in parallel for more current, but NOT in series for more voltage. Loads are fully protected against damage from current overloads, but will be damaged by voltage above the maximum voltage rating. 8 50 W/actual output voltage in volts or actual output voltage in volts/0.05 ohms, whichever is less I must test a 1 volt power supply using a constant current load and I want to use Agilent Electronic Loads. But the Agilent load meets all of its dynamic specs with no derating on down to 3 volts. Below 2 volts, the Agilent load current must be linearly derated. What can I do? I want to put a microswitch on the safety cover over my UUT so that lifting the cover will program my ATE power supplies to zero volts and protect the operator from harm. Do Agilent power supplies have this capability? Use a boost supply in series with the UUT. The load will now meet all its specs with no derating, because it always operates above 3 volts. (see the illustration below) The boost supply can be a low-cost fixed output 3 V or 5 V supply with a current rating at least as high as the maximum peak load current needed. The 6641A (8 V, 20 A), 6651A (8 V, 50 A), 6671A (8 V, 220 A), or 6681A (8 V, 580 A) are all excellent choices. The voltage setting of a programmable boost supply should be set to 3 volts, and the current limit set to full scale. Select a boost power supply with low p-p ripple and noise. The constant current load will compensate for low-frequency p-p ripple and noise below a few kHz, but high frequency ripple and noise from the boost will appear across the UUT. 6690 6600 Watt 6 Yes, many Agilent power supplies have a feature called "Remote Inhibit" (RI). When connected to the RI input on the rear of the power supply, a contact closure or TTL low signal causes the output of the supply to shutdown and be programmed to zero volts. The power supply can also be set to generate a service request (SRQ) via the GPIB in the event that RI is pulled low. Boost Supply + Out + Sense - Out - Sense + Sense + Out I Load Agilent Load + Out + Sense - Sense - Out UUT - Sense - Out More detailed specifications at www.agilent.com/find/power 120 10 Most frequently asked questions about using Applications Information DC power products (Continued) Power Products 9 Why are Agilent's Electronic Loads constant resistance resolution speced in ohms on the low resistance range, but in mSiemens on the two higher ranges? In general, Agilent's Electronic Loads are not a conventional "resistor". The loads consist of IC's, capacitors, resistors, FETs, etc. They were designed with two major circuits, a cv and cc circuit. These circuits are used to simulate resistance on the two upper ranges. First, it is necessary to understand why there is a difference in the way in which the ranges are specified (mohms or mS). The constant resistance (CR) mode in the load actually operates using either the constant current (CC) or constant voltage (CV) circuits inside the load. The lowest CR range uses the CV regulating circuits, while the two higher ranges use the CC regulating circuits. It is because of these differences in the circuits used to regulate the load input that the specifications need to be different. When the CV circuits are used, the load can be viewed as many resistors, all the same value (the resolution), in series to produce the desired resistance. Then, changing the resistance is like changing the number of discrete resistors in series. Therefore, the resolution is the value of one of these series resistors, and putting resistors in series changes the resistance measured in ohms. For the N3302A, the "discrete resistor" or resolution that can be programmed is 0.54 mohms in the 2 ohm range. When the CC circuits are used, the load can be viewed as many resistors, all the same value (the resolution), in parallel to produce the desired resistance. Then, changing the resistance is like changing the number of discrete resistors in parallel. Therefore, the resolution is the value of one of these parallel resistors, and putting resistors in parallel changes the conductance measured in siemens. For the 60501B, the "discrete resistor" or resolution that can be programmed is 0.14 mS (=7.14 kohms). For example, in the 2 kohm range, you can program the load input from 2 ohms to 2 kohms (0.5 S to 0.5 mS) with a resolution of 0.14 mS. This would be the equivalent of starting with about 3568 7.143 kohm resistors in parallel with each other, and in parallel with a 2 kohm resistor, and removing one at a time until you had only the 2 kohm resistor left. Note that the resolution of the conductance is constant at 0.14 mS, however, the resolution of the total parallel resistance is not constant. It depends on how many resistors you have in parallel. If you have two 7.143 kohm resistors in parallel and remove one, the resolution looks like 3571.5 ohms. If you have 3568 7.143 kohm resistors in parallel and remove one, the resolution looks like (7143/3567) (7143/3568) = 0.561 mohms. But the conductance resolution is constant at 0.14 mS. More detailed specifications at www.agilent.com/find/power 121 10 Most frequently asked questions about using Applications Information DC power products (Continued) Power Products 10 Can Agilent power supplies be programmed from 0 to full output voltage using a 0 to 10 V signal source? Yes, many Agilent power supplies feature remote voltage programming or analog programming capability. However, there is a potential danger in analog programming any power supply, especially a high voltage supply. If the 0 to 10 V programming source is a typical, non-isolated, low-cost, digital-to-analog converter (DAC), it is probably grounded through its digital inputs and/or through the computer's internal power supplies, which are grounded through the computer's power cord. It's easy to overlook this, and the mistake can be very expensive. If the DAC is non-isolated (or isolated only up to 42 V above ground) and one of the output terminals of the power supply is grounded, either directly or through the UUT, the output capacitor of the power supply can discharge through the computer backplane, motherboard, and the I/O common through the computer power cord ground. The resulting high current may even last long enough to vaporize the thin ground tracks on some or all of the printed circuit boards in the PC. Be sure the programming source is electrically isolated, is operated from isolated power supplies, and is rated for floating voltages up to the full output voltage of the programmed supply. This is necessary so no one is hurt, and no equipment is damaged, no matter which output terminal of the power supply or UUT is grounded. For additional questions and answers visit our web site at www.agilent.com/find/answers More detailed specifications at www.agilent.com/find/power 122 Power Products AC Power and Load Connections Applications Information A modern stabilized DC power supply is a versatile high performance instrument capable of delivering a constant or controlled output reliably and with little attention. But to take full advantage of the performance characteristics designed into a supply, certain basic precautions must be observed when connecting it for use on the lab bench or installing it in a system. Factors such as wire ratings, system grounding techniques, and the particular way that AC input, DC output, and remote error sensing connections are made can contribute materially to obtaining the stable, low noise output expected by the user. Careful attention to the following guidelines can help to ensure the trouble free operation of your Agilent power supply. AC Power Input Connections Wire Rating RULE 1. When connecting AC power to a power supply, always use a wire size rated to carry at least the maximum power supply input current. If a long cable is involved, make an additional check to determine whether a still larger wire size might be required to retain a sufficiently low impedance from the service outlet to the power supply input terminals. As a general guideline, input cables should be of sufficient size to ensure that the voltage drop at maximum rated power supply input current will not exceed 1% of the nominal line voltage. Continuity RULE 2. Maintain the continuity of the AC, acc, and grounding wires from the AC power outlet to the power supply input terminals without an accidental interchange. Interchanging the AC and grounding wires may result in the power supply chassis being elevated to an AC potential equal to the input line voltage. If the chassis is grounded elsewhere, the result may be no worse than some blown fuses. But if the chassis is not grounded, the result could be a potentially lethal shock hazard. Confirm that the chassis is grounded by the grounding wire. Transformers RULE 3. If an autotransformer or an isolation transformer is connected between the AC power source and the power supply input terminals, it should be rated for at least 200% of the maximum rms current required by the power supply. The transformer must have a higher rating than would be suggested by the supply's rms input current because a power supply input circuit does not draw current continuously. Input current peaks can cause a smaller transformer to saturate, resulting in failure of the supply to meet its specifications at full output. RULE 4. Be sure to connect the common terminal of an autotransformer to the acc (and not the AC) terminals of both the power supply and the input power line. If acc is not connected to the common terminal of the autotransformer, the power supply's input acc terminal will have a higher than normal AC voltage connected to it, contributing to a shock hazard and, in some instances, a greater output ripple. AC Line Regulator RULE 5. Do not use an AC line regulator at the input to a regulated power supply without first checking with the power supply manufacturer. Some regulators tend to increase the impedance of the line in a resonant fashion and can cause power supplies to malfunction, particularly if they use SCR or switching regulators or preregulators. Moreover, since the control action of many line voltage regulators is accompanied by a change in the output waveshape, their advantage in providing a constant rms input to a power supply is small. In fact these changes in waveshape are often just as disruptive in causing power supply output changes as the original line voltage amplitude changes would have been. More detailed specifications at www.agilent.com/find/power 123 AC Power and Load Connections (Continued) Power Products Applications Information STEP 1. Select a load wire size that, as an absolute minimum, is heavy enough to carry the power supply output current that would flow if the load terminals were short-circuited. Load and Remote Error Sensing Connections Making Load Connections to One Power Supply The simplest and most common example of improper load wiring is shown in Figure 1. The voltage at each load depends on the current drawn by the other loads and the voltage drops they cause in some portion of the load leads. Since most load currents vary with time, an interaction among the loads results. This interaction can sometimes be ignored, but in most applications the resulting noise, pulse coupling, or tendency toward inter-load oscillation is unacceptable. The following thirteen steps describe a recommended procedure for connecting the load wiring, grounding the system in a manner that avoids troublesome ground loops, and making connections for remote error sensing. This is the minimum, however. Impedance and coupling considerations usually dictate the use of load wires larger than would be required just to satisfy current rating requirements. In general, the power supply performance degradation seen at the load terminals becomes significant when the wire size and length result in a load wire impedance comparable to or greater than the effective output impedance of the power supply. Refer to a copper wire resistance table to see if a larger wire size might have to be used to attain an impedance comparable to or smaller than the output impedance of the power supply. Power Supply + Load No1 Load No2 Load No3 If multiple loads are supplied from a pair of DC distribution terminals not located at the power supply terminals, it is necessary to consider separately the mutual impedance of the wires connecting the power supply to the distribution terminals and the additional impedance of the wires to each individual load. The mutual impedance presents an opportunity for a variation of one load current to cause a DC voltage variation at another load. Fortunately this mutual impedance can be effectively reduced at DC and at low frequencies by using remote error sensing, as will be described later. Connect the Load Wiring STEP 2. Designate a single pair of terminals as the positive and negative DC distribution terminals. These two terminals might be the power supply output terminals, the load terminals, or a separate pair of terminals established expressly for distribution. If the power supply is a short distance from the load and remote sensing will not be used, locate the DC distribution terminals as near as possible to the power supply output terminals. Using the power supply output terminals themselves as the distribution terminals results in optimum performance. Figure 1 Improper load connections More detailed specifications at www.agilent.com/find/power 124 AC Power and Load Connections (Continued) Power Products Applications Information If remote sensing is to be used, locate the DC distribution terminals as near as possible to the load terminals. Later in the procedure, sensing leads will be connected from the power supply sensing terminals to the DC distribution terminals as shown in Fig. 2. Power Supply + +S Load -S - With One Load Power Supply + STEP 3. Connect one pair of wires directly from the power supply output terminals to the DC distribution terminals, and connect a separate pair of wires from the distribution terminals to each load. There should be no direct connection from one load to another except by way of the DC distribution terminals. (Although for clarity the diagrams show the load and sensing leads as straight lines, some immunity against pick-up from stray magnetic fields can be obtained by twisting each pair of load leads and shielding all sensing leads.) Decouple Multiple Loads +DT +S Load No. 1 -S -DT Keep these four load wires as short as possible, use large wire size Load No. 2 With Multiple Loads Figure 2 Location of DC Distribution Terminals with Remote Sensing (Distribution Terminals are Shown Solid) STEP 4. If required, connect a local decoupling capacitor across each pair of distribution and load terminals. Load decoupling capacitors are often needed when multiple loads draw pulse currents with short rise times. To reduce high frequency mutual coupling effects under these circumstances, capacitors must be connected directly across the load and distribution terminals. The capacitors used for decoupling must be selected to have a high frequency impedance that is lower than the impedance of the wires connected to the same load, and their connecting leads must be kept as short as possible to minimize impedance. Grounding the System Since no two ground points have exactly the same potential, the idealized concept of a single ground potential is a snare and a delusion. In many cases the potential difference is small, but a difference in two ground potentials of even a fraction of a volt could cause amperes of current to flow through a complete ground loop. (Ground loop is a term used to describe any conducting path formed by two separate connections to ground). Ground loops can cause serious interference problems when voltages developed by these currents are coupled into sensitive signal circuits. To avoid ground loop problems, there must be only one ground return point in a power supply system. (A power supply system includes the power supply, all of its loads, and all other power supplies connected to the same loads). The selection of the best ground return point depends on the nature and complexity of the DC wiring. In large systems, practical problems frequently tend to force compromises with the ideal grounding concept. For example, a rack mounted system consisting of separately mounted power supplies and loads generally has multiple ground connections. Each instrument usually has its own chassis tied to the third grounding wire of its power cord, and the rack is often connected by a separate wire More detailed specifications at www.agilent.com/find/power 125 AC Power and Load Connections (Continued) Power Products Applications Information to ground. With the instrument panels fastened to the rack frame, circulating ground currents are inevitable. However, as long as these ground currents are confined to the ground system and do not flow through any portion of the power supply DC distribution wiring, their effect on system performance is usually negligible. To repeat, separating the DC distribution circuits from any conductive paths in common with ground currents DC System Consisting of all interconnected power supply outputs, their DC distribution wiring and associated load circuits. DC Common Point (CP) DC ground connection Only one wire or connection is permitted if ground loop currents are to be kept out of dc system DC Ground Point (CP) will in general reduce or eliminate ground loop problems. The only way to avoid such common paths is to connect the DC distribution system to ground with only one wire. Figure 3 illustrates this concept: DC and signal currents circulate within the DC system, while ground loop currents circulate within the ground system. Steps, 5, 6, and 7 make specific recommendations for avoiding ground loop problems. Power Supply + +S S.G. Ground System All eventually lead to earth ground Figure 3 Isolating Ground Loop Paths from the DC system Load -S - GP CP A. Without Remote Sensing Power Supply + +S S.G. GND Load -S - Select the DC Common Point B. With Remote Sensing STEP 5. Designate one of the DC distribution terminals as the DC common point. There should be only one DC common point in a DC system. If the supply is to be used as a positive source, then the negative DC distribution terminal is the DC common point. If it is to be a negative source, then the positive DC distribution terminal is the DC common point. Here are some additional suggestions for selecting the best DC common point for five different classes of loads: S.G. = "Safety Ground" lead in power cord - connected to chassis and ground terminals of power supply, and to earth ground GND = Power supply ground terminal a. Single Isolated Load. A single isolated load exists when a power supply is connected to only one load and the load circuit has no internal connections to the chassis or ground. If the power supply output terminals are to be used as the DC distribution terminals, then the DC common point will be either the positive or negative power supply output terminal (Fig. 4A). If remote sensing is to be used and the load terminals will serve as the distribution terminals, then either the positive or negative load terminal will be the DC common point (Fig. 4B). GP CP Figure 4 Preferred Ground Connections for a Single Isolated Load Power Supply + +S S.G. Consisting of all chassis for power supplies and their load devices, their ground terminals, safety ground, AC ground wiring, rack frames, etc. GND GND Load No. 1 -S - GP CP Without Remote Sensing Load No. 2 Power Supply + +S S.G. GND Load No. 1 -S CP GP With Remote Sensing Load No. 2 Figure 5 Preferred Ground Connections for Multiple Ungrounded Loads More detailed specifications at www.agilent.com/find/power 126 AC Power and Load Connections (Continued) Power Products Applications Information b. Multiple Ungrounded Loads. This alternative applies when separate pairs of load leads connect two or more loads and none of the load circuits has an internal connection to chassis or ground (Fig. 5). Use the positive or negative DC distribution terminal as the DC common point. c. Single Grounded Load. When a power supply is connected to a single load that has a necessary internal connection to chassis or ground as in Fig. 6, or when a supply is connected to multiple loads only one of which has a necessary internal connection to chassis or ground as in Fig. 7, the load terminals of the grounded load must be designated the DC distribution terminals, and the grounded load terminal is necessarily the DC common point. d. Multiple Loads, Two or More of Which are Individually Grounded. This undesirable situation must be eliminated if at all possible. Ground loop currents circulating through the DC and load wiring cannot be avoided so long as separate loads connected to the same power supply or DC system have separate ground returns as shown in Fig. 8. One possible solution is to break the ground connection in all of the loads and then select the DC common point using the multiple ungrounded load alternative as in (b) above. Another would be to break the ground connection in all but one of the loads and select the DC common point as in alternative (c). If there are two or more loads with ground connections that cannot be removed and the system is susceptible to ground loop problems, then the only satisfactory solution is to increase the number of power supplies and to operate each grounded load from a separate supply. Each combination of power supply and grounded load would be treated as in alternative (c). Load No 1 Power Supply + +S S.G. GND -S CP and GP Load No 2 - Without Remote Sensing Load No 3 Load No 1 Power Supply + +S S.G. GND -S Load No 2 CP and GP - With Remote Sensing Load No 3 Power Supply + +S S.G. GND Load -S - CP and GP Without Remote Sensing Figure 7 Preferred Ground Connections for Multiple Loads, Only One of Which is Grounded Internally Power Supply + Load No 1 +S S.G. GND Load -S - Power Supply CP and GP + With Remote Sensing +S S.G. GND -S Load No 2 Ground Voltage Source - Figure 6 Preferred Ground Connections for a Single Grounded Load Load No 3 Figure 8 Improperly Connected DC Distribution System with Two Grounded Loads forming a Ground Loop More detailed specifications at www.agilent.com/find/power 127 AC Power and Load Connections (Continued) Power Products Applications Information e. Load System Floated at a DC Potential Above Ground. It is sometimes necessary to operate the power supply output at a fixed voltage above or below ground potential. The usual procedure in these circumstances is to designate a DC common point using whichever of the preceding four alternatives is appropriate, just as though conductive grounding were to be used. Then connect this DC common point to the DC ground point through a 1 microfarad capacitor as shown in Figure 9. Power Supply + +S S.G. GND Load -S CP 1f GP Figure 9 Floating a Load System at a DC Potential Above Ground Select the DC Ground Point STEP 6. Designate the terminal that is connected to ground as the DC ground point. The DC ground point can be any single terminal, existing or added, that is conductively connected to the ground of the building wiring system and then eventually to earth ground. STEP 7. Connect the DC common point to the DC ground point, making certain there is only one conductive path between these two points. Make this connection as shown in Figures 4, 5, 6, or 7. Make the connection as short as possible and use a wire size such that the total impedance from the DC common point to the DC ground point is not large compared with the impedance from the ground point to earth ground. Flat braided leads are sometimes used to further reduce the high frequency component of the ground lead impedance. Making Remote Error Sensing Connections Normally a power supply operating in the constant voltage mode achieves its optimum line and load regulation, its lowest output impedance, drift, and PARD, and its fastest transient recovery performance at the power supply output terminals. If the load is separated from the output terminals by any lead length (as in Fig. 10), some of these performance characteristics will be degraded at the load terminalsusually by an amount proportional to the impedance of the load leads compared with the output impedance of the power supply. Power Supply + +S -S RL - Figure 10 Load Voltage Variations Caused by Load Lead Voltage Drops when Remote Error Sensing is not Used With remote error sensing, a feature included in nearly all Agilent power supplies, it is possible to connect the input of the voltage feedback amplifier directly to the load terminals so that the regulator performs its function with respect to the load terminals rather than with respect to the power supply output terminals. Thus, the voltage at the power supply output terminals shifts by whatever amount is necessary to compensate for the voltage drop in the load leads, thereby maintaining the voltage at the load terminals constant (Fig. 11). Power Supply +S + Sensing Lead + RL -S - Sensing Lead Figure 11 Regulated Power Supply with Remote Error Sensing. More detailed specifications at www.agilent.com/find/power 128 AC Power and Load Connections (Continued) Power Products Applications Information Making the Sensing Connections STEP 8. Remove the jumper connections between the power supply sensing and output terminals, and connect the power supply sensing terminals to the DC distribution terminals as shown in Fig. 12. Power Supply +DT + +S Load No. 1 -S DT and CP GP Load No. 2 Figure 12 Properly Grounded Power Supply System with Remote Error Sensing Use an insulated shielded pair for the sensing leads. Do not use the shield as one of the sensing conductors. STEP 9. Connect one end of the sensing lead shield to the DC common point and leave the other end unconnected. In nearly all cases this method of connecting the sensing shield minimizes ripple at the DC distribution terminals. Protect Against Open Sensing Leads Step STEP 10. Avoid the possibility of an open remote sensing path, either on a longterm or a transient basis. Opening a sensing lead causes the power supply output voltage to increase. Protective circuits in the supply provide some load protection by limiting the amount of the increase, but eliminating all switch, relay, or connector contacts from the remote sensing path helps to minimize the possibility of any loss of regulation due to this cause. Check the Load Wire Rating STEP 11. Verify that the voltage drop in the load leads does not exceed the capabilities of the remote sensing circuit. Most well regulated power supplies have an upper limit to the load lead voltage drop around which remote sensing can be connected without losing regulation. This maximum voltage drop is typically 0.5, 1, or 2 volts, and may apply to the positive, the negative, or both the positive and negative output leads. See the instruction manual for the exact load lead voltage drop limitations of a particular power supply. Remember too, that any voltage drop lost in the load leads reduces the maximum voltage available for use at the load. Either of these limitations sometimes dictates the use of a larger wire size than would be required by wire current rating or impedance considerations. Check for Power Supply Oscillation STEP 12. Verify that the power supply does not oscillate when remote sensing is connected. Although DC and low frequency performance are improved by remote sensing, phase shifts associated with long load and sensing leads can affect the stability of the feedback loop seriously enough to cause oscillation. This problem can frequently be corrected by readjusting a "transient recovery" or "loop stability" control inside the supply if the circuit includes one; follow the adjustment procedure in the manual. Another remedy that is often effective is to disconnect the output capacitor inside the power supply (some models have a rear panel jumper that can be removed for this purpose) and to connect a similar capacitor across the DC distribution terminals. Check for Proper Current Limit Operation STEP 13. Check that the operating point of the current limit circuit has not been affected by the remote sensing connections. With some power supply designs, the resistance of one of the output conductors adds to the resistance used for current limit monitoring when remote sensing is used. This reduces the threshold value at which current limiting begins and makes readjustment of the current limit More detailed specifications at www.agilent.com/find/power 129 Power Products AC Power and Load Connections (Continued) Applications Information circuit necessary. To determine whether connecting remote sensing has changed the current limit setting, turn off the supply, short terminal -S to -OUT and +S to +OUT at the power supply, and check whether the current limit value differs from the value without these terminals shorted. If it does differ significantly, the current limit control needs readjustment. Power Supply "A" + DT +S C1 Load No. 1 + CA -S 1 C2A - S.G. GND Load No. 2 DT & CP C2B Power Supply "B" GP + Making Load Connections to Two or More Power Supplies in the Same System The following four rules must also be observed in extending the preceding techniques to systems containing two or more power supplies. DC Distribution Terminals RULE 1. There must be only one point of connection between the DC outputs of any two power supplies in the multiple power supply system. This point must be designated as one of the two DC distribution terminals for those two power supplies. Thus there are always exactly (N+1) DC distribution terminals in any system, where N is the number of power supplies. (This is true unless parallel supplies share the same distribution terminals, or supplies are connected in series with no other connections to their intermediate terminals). +S C3 Load No. 3 + CB -S 1 - S.G. GND DT 1 Power supply chassis ground connection via 3rd wire saftey ground lead and rack frame. S.G = "Safety Ground" lead in power cord GND = Power supply ground terminal CA, CB = Power supply output capacitors removed and placed across DT's C1, C2, C3, = Load decoupling capacitors Figure 13 A Properly Connected Multiple Power Supply System DC Common Point RULE 2. One of the (N+1) DC distribution terminals must be designated as the DC common point for the system. There can be only one DC common point allowed in a system. DC Ground Point RULE 3. There must be only one DC ground point in a multiple power supply system. RULE 4. There must be only one conductive path between the system DC common point and the system DC ground point. This rule is repeated from Step 7 above as a reminder because of the far greater number of possible paths to ground in a multiple power supply system. Figure 13 shows an example of a properly connected and grounded multiple power supply system. This rules out the possibility of connecting two grounded loads in the same system. More detailed specifications at www.agilent.com/find/power 130 Power Products Applications Information Power Products Terms AC input current: the maximum current into the power supply or electronic load. The current specified is worst case (low line voltage, full output). Auto-parallel operation: a master-slave connection of the outputs of two or more supplies or the inputs of two or more electronic loads used for obtaining a current rating greater than can be obtained from a single load or supply. Only supplies that have the same voltage and current ratings should be paralleled. Actual transition time: for an electronic load, either the total slew time (voltage or current change divided by slew rate - time) or the minimum transition time, whichever is longer. Slew Rate Voltage (volts) or Current (amperes) 10% 0% Time (microseconds) Risetime Transition Limitation Analog programming: controlling the output voltage and/or current with an analog signal. This signal could be a voltage, current or resistance. This is similar to using the power supply as an amplifier. Common mode noise: the current flowing from either output terminal (+ and -) through the power supply to chassis ground. Compliance voltage: the output voltage of a power supply operating in the constant-current mode. Actual Time Ambient temperature: the temperature of the air immediately surrounding the power supply or electronic load. Auto-tracking operation: a master-slave connection of two or more supplies each of which has one of its output terminals in common with one of the output terminals of all of the other supplies. Command processing time: the average time required for a power supply output voltage, or electronic load input voltage or current, to begin to change following receipt of a voltage or current set command over GPIB. This is effectively the time it takes for the power supply or electronic load to interpret the voltage set command and initiate a response. 100% 90% Expected Time Auto-series operation: a master-slave connection of the outputs of two or more supplies used for obtaining a voltage greater than can be obtained from one supply. Only supplies that have the same voltage and current ratings should be connected in series. Autoranging power supply: a power supply that can provide maximum rated power over a wide and continuous range of voltage and current settings. Constant-current (CC) mode: a power supply that stabilizes output current with respect to changes in load impedance. Thus, for a change in load resistance, the output current remains constant while the output voltage changes by whatever amount necessary to accomplish this. More detailed specifications at www.agilent.com/find/power 131 Power Products Applications Information Constant-current/voltage/resistance mode electronic load: an electronic load that can operate in one of the following ways: CC= ratio of voltage to current in accordance with the programmed value regardless of the input voltage CV= ratio of voltage to current in accordance with the programmed value regardless of the input current Power Products Terms (Continued) Open Circuit Load Constant Voltage Operating Region ES Constant Current Operating Region R L.R C R L=R C R L .R C E OUT E CR= ratio of voltage to current while maintaining the programmed resistance value I Short Circuit Load R L= E I 0 Current Setting Load Current I OUT 0 IS Constant-Voltage/Constant-Current Output Characteristics Input Voltage V Constant-Current Mode I Slope (Resistance Setting) Load Current Input Voltage V Constant-Resistance Mode V Voltage Setting Input Voltage Load Current Constant-current/voltage/resistance regulation: the change in the steadystate value of the stabilized electronic load input voltage, current, or resistance resulting from a full scale source change, with all other influence quantities held constant. Constant-voltage (CV) mode: a power supply that stabilizes output voltage with respect to changes in influence quantities. Thus, for a change in load resistance, the output voltage remains constant while the output current changes by whatever amount necessary to accomplish this. Constant-voltage/constant current (CV/CC) power supply: a power supply that operates as a constant-voltage power supply or a constant-current power supply, depending on load conditions. The supply acts as a constant-voltage source for comparatively large values of load resistance and as a constant-current source for comparatively small values of load resistance. I Constant-Voltage Mode More detailed specifications at www.agilent.com/find/power 132 Power Products Applications Information Power Products Terms (Continued) Constant-voltage/current limiting (CV/CL) power supply: a power supply similar to a constant-voltage/constant-current supply except that at comparatively small values of load resistance, its output current is limited instead of being stabilized. Downprogramming: the ability of a power supply to discharge its output capacitors independently of load. The use of an active down programming device can reduce the fall time of the output voltage. Crest factor: the ratio of the zero-topeak value to the rms value of a waveform. This term is often used to specify the maximum peak amplitude that an AC power supply can source (relative to its maximum rms rating) without distortion. Crowbar: see overvoltage protection. Current limiting: the action, under overload or short-circuit conditions, of limiting the output current of a constant-voltage supply to some predetermined maximum value (fixed or adjustable) and automatically restoring the output voltage to its normal value when the overload or short circuit is removed. There are three types of current limiting: * by constant-voltage/constantcurrent crossover * by decreasing the output voltage as the current increases * by decreasing both voltage and current as the load resistance decreases. DFI: a TTL compatible output signal that can be used as an alarm and automatically initiates an action for multiple power supply or electronic load shutdown. The DFI signal is commonly connected to RI of the next supply. (See RI) Drift: the maximum change of a power supply output or load input voltage or current during an 8-hour period following a 30-minute warmup, with all influence and control quantities maintained constant during the warm-up time and the period of drift measurement. Drift includes both periodic and random deviations over the bandwidth from zero frequency (DC) to a specified upper frequency limit. Efficiency: expressed in percent, efficiency is the total output power of the supply divided by the active input power. Unless otherwise specified, Agilent measures efficiency at maximum rated output power and at worst case conditions of the AC line voltage. Electromagnetic interference (EMI): any type of electromagnetic energy that could degrade the performance of electrical equipment. The EMI generated by a power supply can be propagated either by conduction (via the input and output leads) or bt radiation from the units' case. The terms "noise" and "radiofrequency interference" (RFI) are sometimes used in the same context. Electronic Load: an active device which absorbs power. Loads are used for the testing of the power producing products. Foldback: immediate shutdown of the power supply output when a crossover between constant voltage and constant current mode occurs. Both the voltage and current levels are reduced (folded back). Harmonics: the occurrence of this type of distortion is based upon the mathematical principle that all periodic waveforms are made up of a series of sine waves. As a result, harmonic distortion is produced at frequencies that are integer multiples of the fundamental or desired signal frequency. When viewed in the frequency domain, harmonics have an amplitude (often expressed in db), frequency, and phase characteristic relative to the fundamental. Isolation: the maximum voltage (including output voltage) either output terminal may be floated from earth ground. Load cross regulation: the affect on one output of a multiple output power supply when another output is programmed from zero to full rated current. More detailed specifications at www.agilent.com/find/power 133 Power Products Applications Information Power Products Terms (Continued) Load Effect: also known as "load regulation". Load effect is the change in the steady-state value of the stabilized output voltage or current resulting from a full-load change in the load current of a constantvoltage supply or the load voltage of a constant-current supply, with all other influence quantities maintained constant. Master-slave operation: a method of interconnecting two or more supplies or electronic loads such that one of them (the master) serves to control the others (the slaves). The outputs of the slave supplies or inputs of the slave electronic loads always remain equal to or proportional to the output of the master. The outputs of the master supply and of one or more slaves may be connected in series, in parallel, or with just their negative or positive output terminals in common. (See also "complementary tracking"). The inputs of the master electronic load and one or more slaves may be connected in parallel only. Load effect transient recovery time: the time interval between a specified step change in the load current of a constant-voltage supply (usually a full-load or 5-amp change, whichever is smaller) or in the load voltage of a constant-current supply and the instant when the stabilized output quantity returns to and stays within a specified transient recovery band. Increase Decrease Modulation: analog programming of the output voltage and/or current. The output programming response time determines the maximum slew rate at which the power supplies output can be programmed. Nominal value: the value that exists "in name only"; not the actual value. For example, in the case of a power supply with a calibrated output control, the nominal value is the value indicated by the control setting. For a supply with a fixed output, the nominal output is the output indicated on the nameplate. The nominal value of a 120-volt 10% line voltage is 120 volts. "One-Box": a power supply that can be controlled by direct connection to a computer (with no additional programmers) and that can provide measured data to a computer without external voltmeters or ammeters. Load E OUT (Constant - Voltage Operation) or I OUT (Constant - Current Operation) Minimum transition time: the shortest possible time in which an electronic load input can change from one level to another. This is determined by the small signal bandwidth of the load. Load Effect Transient Recovery Band t Load Effect Transient Recovery Time Load Effect Transient Recovery Waveforms More detailed specifications at www.agilent.com/find/power 134 Power Products Applications Information Power Products Terms (Continued) Phase angle: specifies the time domain phase relationship between two sine waves. The unit of phase angle is the degree, with one cycle corresponding to 360 degrees of phase. 100 Impedence Ohms 10 1 0.1 0.01 0.001 10 0 10 1 10 2 10 3 10 4 Frequency - Hz 10 5 10 6 10 7 Typical Output Impedence of a Constant Voltage Power Supply Output Impedance: at any frequency of load change, Eout/Iout. Strictly speaking, the definition applies only for a sinusoidal load disturbance, unless the measurement is made at zero frequency (DC). The output impedance of an ideal constant voltage power supply would be zero at all frequencies, while the output impedance for an ideal constant current power supply would be infinite at all frequencies. Overcurrent protection: protection of the power supply, electronic load and/or connected equipment against excessive output current. Overvoltage protection: protection of the power supply, electronic load and/or connected equipment against excessive output voltage. Overvoltage protection is usually by means of a crowbar protection circuit, which rapidly places a low resistance shunt across the supply's output terminals to reduce output voltage to a low value if a predetermined voltage is exceeded. A supply equipped with an overvoltage crowbar must also be protected by a means for limiting or interrupting the output current. Peak-to-peak noise: is the range between maximum and minimum noise level. Sometimes called noise "spikes." Peak-to-peak noise is typically low in energy and does not show up in a RMS measurement, 20-20 Mhz. Programming speed: the maximum time required for the programmed output voltage or current to change from a specified initial value (usually zero or maximum output) to a value within a specified tolerance band of a specified newly programmed value (for most models 99.9% or 0.1% of maximum output, respectively) following the onset of a step change in an analog programming signal, or the gating of a digital signal. Readback: the ability of a power supply or electronic load to measure its actual output voltage and/or current, and provide the reading to a computer. Remote sensing: remote sensing, or remote error sensing, is a means by which a power supply or electronic load monitors the stabilized voltage directly at the load or source respectively, using extra sensing leads. The resulting circuit action compensates for voltage drops up to a specified limit in the load leads. Resolution: for a bench supply, the smallest change in output voltage or current that can be obtained using the front panel controls. For a system supply or electronic load, the smallest change that can be obtained using either the front panel controls, or a computer. Reverse voltage protection: protection of the power supply or electronic load against reverse voltage applied at the outputor input terminals. More detailed specifications at www.agilent.com/find/power 135 Power Products Applications Information Power Products Terms (Continued) RI (discrete fault indicator/remote inhibit): a rear-panel port that can be used to disable the power supply output independently of the GPIB. This port can also be used to chain multiple power supplies together such that an emergency shutdown of one output automatically signals the other supplies to disable their outputs. Series regulation: power supplies designed with this topology have fast programming speeds and low noise. Also referred to as a "linear" topology. Ripple and Noise (dB): a term often used to specify rms or peak AC source noise relative to the maximum rms or peak output rating. The specification is calculated as follows: dB = 20 Log (Vnoise/Vrating). Rms (or effective) amplitude or noise: an average signal or noise level based on energy content. The root mean square (rms) content is often called the AC component. SCPI (Standard Commands for Programmable Instruments): is a programming language for controlling instrument functions over the GPIB (IEEE 488) instrument bus. The same SCPI commands and parameters control the same functions in different classes of instruments. Serial link: a means by which up to 16 power supplies with this feature can share one GPIB primary address. The power supplies can be connected with cables similar to U.S. modular telephone cables. They are independently controlled using GPIB secondary addressing. Slave operation: see "master-slave operation". Slew rate: for any given electronic load input transition, the change in current or voltage over time. Source effect: also known as "line regulation", source effect is the change in the steady-state value of the stabilized output or input voltage or current resulting from any change in the AC source voltage within its specified range, with all other influence quantities maintained constant. Source effect may be measured at any output or input voltage and current within rating. Specifications: describe the power supply or electronic load warranted performance. Total harmonic distortion: the ratio of the rms sum of the harmonic components to the rms value of a periodic waveform. This is typically expressed as a percent or in decibels (dB). Voltage limiting: the action of limiting the output voltage of a constant-current supply to some predetermined maximum value (fixed or adjustable) and automatically restoring the output current to its normal value when the load conditions are restored to normal. There are two types of voltage limiting: * by constant voltage/constant current crossover * by decreasing the output current as the voltage increases Warm-up time: the time interval from when a power supply or electronic load is turned on until its output complies with all performance specifications. Supplemental characteristics: give typical but nonwarranted performance parameters. Switching regulation supplies: power supplies designed with this topology are efficient and can have laboratory-grade specifications. Temperature effect coefficient: the maximum steady-state change in a power supply's output voltage or current or electronic load's input voltage or current per degree Celsius following a change in the ambient temperature within specified limits, with all other influence quantities maintained constant. More detailed specifications at www.agilent.com/find/power 136 Data Acquisition/Switch Instruments Selection Guide L4400 Series Switch & Control Instruments 34970A Data Acquisition Switch Unit 34980A Multifunction Switch/Measure Unit Number of Available slots & modules 7 standalone instruments 3 slots & 8 modules 8 slots & 19 modules Integrated DMM N/A 6 1/2 digit 6 1/2 digit Max Scan Speed 100 ch/sec 250 ch/s 1000 ch/s Max 2-wire Mux Channels 40 60 560 Max 2-wire Matrix Crosspoints 64 96 1024 300 V 300 V 300 V 5A 1A 5A 10 MHz 100 KHz 10 MHz 64 ch 48 ch 510 ch 4 ch 6 ch 32 ch Max RF Frequency custom 2 GHz 3 GHz Max Microwave Frequency custom N/A 20 GHz, custom Available Module Functionality Max Voltage Max Switching Current Max Counter/Totalizer Frequency Max Digital I/O Channels Max Analog Outputs Breadboard (for custom circuits) available Web Interface (via web browser) yes yes Connectivity LAN, optional GPIB IntuiLink SW GPIB, RS-232, Optional USB w/ 82357A BenchLink Data Logger SW LAN, USB, GPIB IntuiLink SW More detailed specifications at www.agilent.com/find/dataacquisition 137 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments Features switching, digital I/O, analog outputs and counter functionality in compact, self-contained LXI instruments 3 * LXI class C compliant Summary of L4400 Series LXI Instruments * Small, 1U, half-rack size offers a broad range of functionality to meet a wide variety of application needs in design verification, automated test and data acquisition. * Built-in Ethernet connectivity * Full-featured graphical Web interface Low Frequency Switching * Standard Dsub connectors for flexible connection options L4421A 40 Channel Armature Mux * Software drivers for most common programming environments The Agilent L4400 Series LXI instruments are high-performance LXI class C compliant instruments that encompass all benefits of LXI with an Ethernet connection, instrument Web server, standard software drivers and more. With their small size and Ethernet connectivity, these instruments are easily placed anywhere on the network. Max Volts Max Current Scan Ch/s 300 V 1A 100 L4433A Dual 4x8 Reed Matrix 150 V 0.5 A 500 L4437A 28 Channel Form C 300 V 1A N/A 30 VDC/250 VAC 5 A N/A 4 Channel Form A RF and Microwave Switching L4445A Microwave Switch/Attenuator Driver Drive up to 64 external switch coils; 32 SPDT switches, 8 multiport switches, 8 attenuators, or custom combination System Measurement and Control L4450A 64-Bit Digital I/O with Memory and Counter Eight 8-bit digital I/O channels with programmable polarity, thresholds up to 5 V with handshaking protocols and 128 kB pattern memory. Two 10 MHz frequency counters and programmable clock output L4451A 4-Channel Isolated D/A Converter with Memory Output DCV up to 16 V or DC current up to 20 mA, Output waveforms w/200 kHz update rate and 16 bit resolution. 500 k memory for waveforms. Four independent D/A converters. L4452A Multifunction Module Four 8-bit digital I/O channels, 2 Channel 12 V analog outputs, 100 kHz gated totalizer More detailed specifications at www.agilent.com/find/L4400 138 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Ethernet connectivity enables simple connection to the network and remote access to your measurements You can set up a private network to filter out unwanted LAN traffic and speed up the I/O throughput, or take advantage of the remote capabilities and distribute your tests worldwide. Use the built-in graphical web interface for remote access and control of your instruments via a Java-enabled web browser Monitor, troubleshoot, or debug your application remotely. The web interface includes features that allow you to view and modify instrument setup, setup and initiate scans or switch sequences, and get status reports on relay counts, firmware revisions and more. System connections you can trust The L4400 series instruments come with standard Dsub connectors for simple, reliable connection options that include quick disconnect terminal blocks, cables and connector kits. Software drivers and connection tools to work in your environment The Agilent IO Libraries Suite makes it easy for you to configure and integrate instruments into your system -- even if your system includes instruments from other vendors. Additionally, these instruments include IVI and LabVIEW software drivers making it easy Figure 1. L4433A Dual 4 x 8 matrix web interface to program in the most popular programming environments including Agilent VEE and T&M Toolkit, National Instruments LabVIEW and LabWindows, and Microsoft programming languages. Agilent's family of LXI instruments offer versatility In addition to the L4400 Series LXI instruments, Agilent offers the 34980A Switch/Measure unit for high-density systems. So whether you need a full-blown switching system with high-density switching, measurement and system control, or just a few channels of switching, Agilent's family of LXI switch/ measure instruments have great versatility so you can choose what you need and easily add to it when your requirements change. See the L4400 and 34980A specific datasheets for more product information and ordering details. More detailed specifications at www.agilent.com/find/L4400 139 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) H * 40 2-wire latching armature relays * Thermocouple reference junction for temperature measurements (reqs ext DMM) ABus1 I 041 L I Fuse L I Fuse 043 L I Fuse 044 L I Fuse 042 931 H L H L H ABus2 DMM (SENS) L H 921 H L ABus3 L H 922 ABus4 L 923 H L 924 L COM 2 * Scan up to 100 ch/s * 300 V, 1 A switch; 2 A carry current Four additional fused inputs (44 channels total) can route up to 1 A of current to an external DMM, allowing for AC and DC current measurements without the need for external shunt resistors. H DMM (MEAS) Current L Current * Relay counter The L4421A is a versatile multiplexer for general purpose scanning. The low thermal offset characteristics and built-in thermocouple reference on the terminal block, make it ideal for temperature measurements with an external DMM. The dense, multifunction switching with 100 ch/s scan rates addresses a broad spectrum of data acquisition, design verification and functional test applications. L Analog Buses L4421A 40-Channel Armature Multiplexer 021 026 031 036 022 027 032 037 023 028 033 038 024 029 034 025 H L H 030 L 039 H 035 L 040 H L Bank 2 Figure 2. L4421A 40-channel armature multiplexer with low thermal offset (bank 2) Specifications and Characteristics Channels/Configurations: 40 2-wire 20 4-wire 4-current (1.5 A fused) Capacitance at Terminal Block: HI-LO LO - earth 150 pF 150 pF General Characteristics Relay Life: typical Switch Type: Armature Latching Input Characteristics (per channel) Max Volts: (DC, AC RMS) 300 V Max Current: (DC, AC RMS) Switch Current: 1 A Carry Current: 2 A Power (W, VA): 60 W Volt-Hertz Limit: 10 8 No Load: 100 M 10 V, 100 mA: 10 M Rated Load: 100 k Scanning Speeds: 100 ch/s Open /Close Time: typical 4 ms/4 ms Analog Bus Connection: Yes Ordering Information L4421A 40-chan Armature Multiplexer General Specifications Offset Voltage: < 3 V Initial Closed Channel Resistance: < 1.5 DC Isolation (ch-ch, ch-earth): > 10 G T/C cold junction accuracy: < 0.8C AC Characteristics Connection Options 34921T Terminal block with temp reference Y1135A 1.5 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1136A 3 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V Bandwidth at Terminal Block: 45 MHz Y1139A Solder cup connector kit with female 50-pin Dsub Crosstalk at Terminal Block (ch-ch): Y1160A Rack mount kit for two 300 kHz 1 MHz 20 MHz 45 MHz L4400 series instruments 75 dB 75 dB 50 dB 40 dB More detailed specifications at www.agilent.com/find/L4400 140 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) L4433A Dual/Quad 4 x 8 Reed Matrix * Configure as Dual 4x8, 8x8, or 4x16 2-wire matrix * 64 2-wire or 128 1-wire cross-points * High speed reed relays * Analog bus connection * Relay counter * 150 V peak, 0.5 A switch, 1.5 A carry current The L4433A is a full cross-point Figure 3. L4433A Dual/Quad 4 x 8 Reed Matrix matrix that offers a flexible connection path between your devices and your test equipment. Each cross- Specifications and Characteristics Channels/Configurations: point in the matrix switch has dual 4 x 8, 8x8, 4 x 16, 2-wire two wires--a high and a low for quad 4 x 8, 1-wire the measurement or the matrix can Switch Type: be configured as a 1-wire matrix, Reed non-latching increasing the number of crosspoints to 128. The L4433A also has in-rush Input Characteristics (per channel) resistors on each column for added Max Volts: 150 V peak protection. Expand your matrix Max Current: (DC, AC RMS) 1 using the analog bus connector to Switch Current: 0.5 A/0.05 A create a larger matrix, or easily conCarry Current: 1.5 A/0.05 A nect to an external measurement Power (W, VA): 10 W device like a DMM. Volt-Hertz Limit: 10 8 Capacitance at Terminal Block: HI-LO LO - earth 80 pF 75 pF General Characteristics Relay Life: typical No Load: 1000 M 10 V, 100 mA: 10 M Rated Load: 10 k Open/Close Time: typical 0.5 ms/0.5 ms Analog Bus Connection: Yes Ordering Information L4433A Dual/Quad 4x8 Reed Matrix General Specifications Connection Options Offset Voltage: 34933T Terminal block for discrete wiring < 50 V, 2-wire < 100 V 1 wire Y1135A 1.5 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V Initial Closed Channel Resistance:1 < 1.5 /200 DC Isolation (ch-ch, ch-earth): > 10 G AC Characteristics Bandwidth at Terminal Block: 30 MHz/4 MHz, 2-wire 2 MHz 1-wire 1 Crosstalk at Terminal Block (ch-ch): 300 kHz 1 MHz 20 MHz 65 dB 65 dB 40 dB Y1136A 3 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1139A Solder cup connector kit with female 50-pin Dsub Y1160A Rack mount kit for two L4400 series instruments 1 Shown with input resistor bypassed and with 100 input protection resistor. Bypassing input resistors will reduce the life of the relays. More detailed specifications at www.agilent.com/find/L4400 141 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Agilent L4437A 32-chan Form A/Form C General Purpose Switch * 28 Form C channels up to 1 A, 60 W NC COM NC * Armature latching relays NO * Temperature sensor for overheating conditions * Simultaneous channel switching The L4437A has 32 general purpose switches that can be used to cycle power to products under test, control status lights, and to actuate external power relays and solenoids. This product has 28 independent single-pole, double-throw (Form C) 1 A relays and 4 single-pole, singlethrow (Form A) 5 A relays. The 28 Form C channels have 300 V, 1 A contacts and can handle up to 60 W. The form A channels are 30 VDC/250 VAC, 5 A contacts and can handle up to 150 W, enough for many power line-switching applications. These switches are made of latching armature relays where multiple channels can be closed at the same time. Additionally, for switching reactive loads, the optional terminal blocks have pads for snubbing circuits. NO COM * 4 Form A channels up to 5 A, 150 W * Relay counter Channel 001 (1A form C relay) NO Channel 028 (1A form C relay) NO COM COM Channel 029 (5A form A relay) Channel 032 (5A form A relay) Figure 4. L4437A 32-Chan General Purpose Switch Specifications and Characteristics Channels/Configurations: 28 Form C 4 Form A Switch Type: Armature Latching Input Characteristics (per channel) Max Volts: (DC, AC RMS) Form C - 300 V Form A - 30 VDC/250 VAC Max Current: (DC, AC RMS) Form C - 1 A switch (2 A carry) Form A - 5 A switch (8 A carry) Power (W, VA): Form C - 60 W Form A - 150 W Volt-Hertz Limit: 10 8 Capacitance at Terminal Block: Ch-Ch - Form C 12 pF/Form A 10 pF Ch-earth - Form C 21 pF/Form A 18 pF General Characteristics Relay Life: no load/rated Form C - 100 M/100 k Form A - 50 M/30 k Open /Close Time: Form C - 4 ms/4 ms Form A - 10 ms/10 ms Initial/Reset Relay State: Form C - maintains state Form A - user configurable Analog Bus Connection: No Ordering Information L4437A 32 Channel Form C/Form A General Purpose Switch General Specifications Offset Voltage: < 3 V Connection Options Initial Closed Channel Resistance: Form C - 125 m Form A - 50 m 34937T Terminal block for discrete wiring Y1135A 1.5 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V DC Isolation (ch-ch, ch-earth): > 10 G Y1136A 3 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V AC Characteristics Bandwidth at Terminal Block: 10 MHz Y1139A Solder cup connector kit with female 50-pin Dsub Channel Isolation at Terminal Block (ch-ch): Y1160A Rack mount kit for two L4400 series instruments 100 kHz 1 MHz 10 MHz 55 dB 35 dB 15 dB More detailed specifications at www.agilent.com/find/L4400 142 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Y1150A-Y1155A distribution boards ordered separately Agilent L4445A Microwave Switch/ Attenuator Driver * Control of most popular microwave switches and attenuators 9-pin cable Power button Status LEDs * Expandable with 34945EXT * Distribution boards allow for easy wiring * Switch read-back capabilities * External power option for simultaneous switching The L4445A allows you to control switches, attenuators and other devices close to your device under test. The L4445A combined with the 34945EXT provides the power and control signals to drive up to 64 switch coils--that's 32 standard SPDT switches. The L4445A can be extended by adding additional 34945EXT extenders. 34945EXT extender holds 4 distribution boards User supplied switches and cables Figure 5. L4445 Microwave Switch/Attenuator Driver with 34945EXT The following microwave switches and attenuators are supported with the Y1150A-Y1155A distribution boards: * N181x series SPDT switches * 8762/3/4 series SPDT switches (screw terminals) * 87104x/106x multiport switches * 87406x series matrix switches * 87204x/206x series * 87222x transfer switches * 849x series attenuators * 8490x series attenuators * Screw terminal connections for other devices including the N9397A/C More detailed specifications at www.agilent.com/find/L4400 143 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Agilent L4445A Microwave Switch/ Attenuator Driver (Continued) Specifications and Characteristics 34945EXT Switch Drive 64 channels, Low Side Drive Mode Driver Off voltage (max): 30 V Driver Off Leakage Current: 500 A Driver On Current (max): 600 mA Driver On Voltage (max): 0.5 V @ 600 mA 64 channels, TTL drive mode Hi output voltage: 3 V @ Iout = 2 mA Lo Output Voltage: 0.4 V @ Iin = 20 mA Lo Input Current: 20 mA 34945EXT position indicator sense inputs Channels: 64 Lo Input Voltage (max): 0.8 V Hi Input Voltage (min): 2.5 V Input resistance: > 100 k @ Vin 5 V > 20 k @ Vin > 5 V Maximum Input Voltage: 30 V 34945EXT switch drive power supply (34945EXT powered by L4445A) Voltage: 24 V nominal (external power supply required for switches needing different voltages) Current: 100 mA continuous + LED indicator (Current mode divers) Channels: 64 Supply Voltage: 5 V nominal LED Drive Current: 5 mA nominal (prog 1-20 mA) Driver Compliance Voltage: 0.8 V Maximum 8 34945Ext's per L4445A Ordering Information L4445A Microwave Switch/Attenuator driver (requires 34945EXT extender) Accessories Y1150A distribution board for 8 N181x SPDT switches Y1151A distribution board for two 87104x/ 106x multiport or 87406B matrix switches Y1152A distribution board for one 87204x/206x or 87606B switch and two N181x switches Y1153A distribution board for two 84904/5/6/7/8 or 8494/5/6 step attenuators Y1154A distribution board for two 87222 transfer switches and six N181x SPDT switches Y1155A distribution board w/generic screw terminals for driving 16 switch coils 200 mA (15 ms pulse, 25% duty cycle) Y1157A 9- to 10-pin cable kit for Y1150A, Y1152A, Y1154A - supplies to build 4 cables 34945EXT external power connection Y1158A 10- to 10/10- to-14-pin cable kit for Y1153A, Y1154A - supplies to build 2 cables Voltage Range: 4.75 V to 30 V Current limit: 2 A Y1159A 16- to 16-pin cable kit for Y1150A/51A/52A/53A/54A/55A supplies to build 2 cables Y1160A Rack mount kit for two L4400 series instruments More detailed specifications at www.agilent.com/find/L4400 144 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Agilent L4450A 64-Bit Digital I/O with Memory and Counter Bank 1 * 64 bi-directional digital I/O bits with programmable polarity 8...% * Variable threshold from 0 V to 5 V 8...% * Handshaking protocols 8...% * Source/sink current up to 24 mA * 128 kB pattern memory Bank 2 INTR Bit0 * * * Bit7 Bit8 * ** Bit15 Bit16 ** * Bit23 Bit24 ** * Bit31 H0 H1 H2 DIO bank 1...8 8...% * Two 10 MHz counter channels * 20 MHz divide-by-n clock The high-speed L4450A digital I/O can be used to simulate or detect digital patterns. It has 64-bits of digital I/O with handshaking, pattern memory; two 10 MHz counters with gate functions; and a programmable clock output. The 64 bi-directional lines are configured as eight 8-bit channels. Each 8-bit channel has programmable polarity and thresholds up to 5 V. The 128 k of memory is useful for simulating and capturing digital patterns up to 10 MHz. The configurable handshaking protocols can be used for a wide variety of applications. 32 Bits INTR Counter/ totalizer 1...8 IN Gate Channel 101 8...% Channel 102 8...% Channel 103 8...% Channel 104 8...% Channel 301 24 Bits DIO bank 2...8 Bit0 ** * Bit7 Bit8 * * * Bit15 Bit16 ** * Bit23 Bit24 ** * Bit31 H0 H1 H2 Clock out Channel 201 Channel 202 Channel 203 Channel 204 CLK 20 MHz - 10 Hz 32 Bits Counter/ totalizer 2...8 IN Gate Channel 302 Figure 6. L4450A 64-bit digital I/O The two counter channels can be used to count events, frequency, period, duty cycle, pulse width and totalize. More detailed specifications at www.agilent.com/find/L4400 145 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Agilent L4450A 64-Bit Digital I/O with Memory and Counter (Continued) Specifications and Characteristics System Clock Generator Characteristics Frequency: Digital Input/Output Characteristics Eight 8-bit channels: 8 bits wide, input or output, non-isolated Vin: 0 V - 5 V Vout: 1.65 V - 5 V I out (max): 24 mA Frequency (max): 10 MHz I Load (max): 400 mA tr + tf (typ): 6 ns 20 MHz - 10 Hz configurable divide-by-n 24-bits, programmable on/off Vout: 1.65 V - 5 V Accuracy: 100 ppm Ordering Information L4450A 64-bit Digital I/O with memory and counter Connection Options Handshake Lines Vin: 0 V- 5 V Vout: 1.65 V- 5 V Iout (max): 24 mA Frequency (max): 10 MHz Counter Function Characteristics Maximum Freq: 10 MHz (max) 50% duty cycle Vin: 0 V- 5 V 34950T Terminal block for discrete wiring Y1137A 1.5 m 78-pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1138A 3 m 78-pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1142A Solder cup connector kit with male 78-pin Dsub Y1160A Rack mount kit for two L4400 series instruments Totalizer Function Characteristics Maximum Count: 2^32 - 1 (4,294,967,296) Max Input Freq: 10 MHz (max), rising or falling edge programmable Vin: 0 V- 5 V Gate Input: 0 V - 5 V More detailed specifications at www.agilent.com/find/L4400 146 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Agilent L4451A 4-Channel Isolated D/A Converter with Memory * Four isolated analog outputs * Outputs up to 16 V or 20 mA DC * 16-bits of resolution * 500 k memory * 200 kHz update rate * Default standard waveforms The Agilent L4451A has four isolated analog channels that are useful to source bias voltages to your device under test, to control your analog programmable power supplies, or use the outputs as setpoints for your control systems. You can use the standard waveforms provided or create your own using over 500,000 points. These points can be dynamically allocated among one or more channels and output as a point-to-point arb. The four independent, isolated channels can output DC voltage up to 16 V or DC current up to 20 mA with 16 bits of resolution. The gain and offset can be adjusted on-the-fly. And since these are isolated channels, they can be stacked to create waveforms with higher output voltages. Figure 7. L4451A 4-channel isolated D/A converter More detailed specifications at www.agilent.com/find/L4400 147 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Agilent L4451A 4-Channel Isolated D/A Converter with Memory Specifications and Characteristics Phase-locking I/O Trigger Characteristics Output Specifications Trigger Input Input Level: TTL compatible (Continued) 200 kHz point-to-point Monotonic: to 16 bits Maximum Update Rate: Isolation: > 80 VDC/AC peak (chan-to-chassis or chan-to-chan) Synchronization: Software commands or external trigger Internal/External CLK Accuracy: 100 ppm AC Accuracy: Not specified DC Voltage Amplitude: 16 V up to 10 mA Resolution: 16-bit = 500 V Amplitude Accuracy (DC): (0.05% + 3.0 mV) Ripple and Noise: < 2 mVrms, 20 Hz to 250 kHz into 10 k load Settling Time: 40 s (-full scale to +full scale step, single channel, to rated accuracy) Output Impedance: < 1 with the load sensed (3.3 V logic, 5 V tolerant) Slope: Rising or falling, selectable Pulse Width: > 100 ns Input Impedance: > 10 k, DC coupled Trigger Output Level: TTL compatible into 1 k (3.3 V logic) Output Impedance: 50 typical Clock Input Input Level: TTL compatible (3.3 V logic, 5 V tolerant) Input Impedance: > 10 k, DC Maximum Rate: 10 MHz Clock Output Level: TTL compatible Into 1 k (3.3 V logic) Output Impedance: 50 typical Maximum Rate: 10 MHz Accuracy: 100 ppm Ordering Information L4451A 4-Channel Isolated D/A Converter with Memory Connection Options DC Current Range: 20 mA 34951T Terminal block for discrete wiring Resolution: 16-bit = 630 nA Y1135A 1.5 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V Accuracy: (% value + amps) (temperature within 5C of Tcal or *Cal?) 90-day: (0.09% + 5.0 A) Ripple and Noise: < 2 Arms, 20 Hz to 250 kHz into 250 Compliance Voltage: 12 V Max Open Circuit Voltage: < 22 V Y1136A 3 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1141A Solder cup connector kit with male 50-pin Dsub Y1160A Rack mount kit for two L4400 series instruments More detailed specifications at www.agilent.com/find/L4400 148 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) Agilent L4452A Multifunction with Digital I/O, D/A, Totalizer * 32-bits of digital I/O up to 42 V * 100 kHz gated totalizer * Two 12 V analog outputs with 1 mV of resolution The L4452A is a multifunction instrument that combines four 8-bit channels of digital input and output, a 100 kHz gated totalizer, and two 12 V analog outputs all on a single earth-referenced module. The digital I/O supports output levels up to 42 V. These channels can be used with an external power supply to control external devices or to sense limit switch and digital bus status with no complex handshake modes. The analog outputs can output up to 12 V or 10 mA DC with 1 mV of resolution. They can be used to source bias voltages to your device under test, to control your analog programmable power supplies, or use the outputs as set points for your control systems. The totalizer inputs can be used to count events and can be included in a scan. Alarm limits for the digital and event counter inputs are evaluated continuously, capturing and logging alarm conditions even between scans. Specifications and Characteristics Internal to the 34952A Module User-Supplied Connections Digital input/output characteristics Four 8-bit Channels, 8-bits Wide: Input or output, non-isolated Vin(L): < 0.8 V (TTL) Vin(H): > 2.0 V (TTL) Vout(L): < 0.8 V @ Iout = -400 mA Vout(H): > 2.4 V @ Iout = 1 mA Vin(H) max: < 42 V with external open drain pull-up Alarm: Maskable pattern match or state change Speed: 4 ms (max) alarm sampling latency Read/Write Speed: 95/s Bit 0 8 Channel 001 Bit 7 Bit 8 8 Channel 002 DIO Bit 15 Bit 16 8 Channel 003 Bit 23 Bit 24 8 Channel 004 Bit 31 32 Bits Totalizer Totalize Input Characteristics Count + Count Gate Gate Channel 005 Max Count: 226 - 1 Totalize Input: 100 kHz (max) rising or falling edge, programmable Signal Level: 1 Vp-p (min) 42 Vpk (max) Threshold: 0 V or TTL Gate Input: TTL-Hi, TTL-Lo, or none Count Reset: Manual or read + reset Read Speed: 85 rdgs/s 16 Bits D/A1 DAC 1H DAC 1L Channel 006 D/A2 DAC 2H DAC 2L Channel 007 16 Bits Analog Output Characteristics DAC 1, 2: 12 V, non-isolated Resolution: 1 mV Figure 8. L4452A Multifunction with Digital I/O, D/A, totalizer Iout: 10 mA max Settling Time: 1 ms to 0.01% of output Accuracy: (% of output + mV) 1 year (0.25% + 20 mV) Temp. Coefficient: (0.015% + 1 mV)/C Ordering Information L4452A Multifunction instrument with digital I/O, D/A converters and totalizer Connection Options 34952T Terminal block for discrete wiring Y1135A 1.5 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1136A 3 m 50-pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1141A Solder cup connector kit with female 50-pin Dsub Y1160A Rack mount kit for two L4400 series instruments More detailed specifications at www.agilent.com/find/L4400 149 Switching and Control Instruments L4400 Series LXI Switching and Control Instruments (Continued) L4400 General Specifications L4400 General Specifications Software Agilent connectivity software included: Power Supply: Universal 100 V to 240 V 10% Power Line Frequency: 50 Hz to 60 Hz 10% automatically sensed Agilent I/O Libraries Suite 14 or greater (E2094N) Minimum System Requirements: PC hardware Power Consumption: 15 VA Operating Environment: Intel Pentium 100 MHz, 64 MB RAM, 210 MB disk space Full accuracy for 0C to 55C Full accuracy to 80% R.H. at 40C Display Pollution Degree: 1 of IEC 61010-1 Operating system Storage Environment: Windows(R) 98 SE/NT/2000/XP -40C to 70C Computer Interfaces: Approximate Dimensions: Standard LAN 10BaseT/100BaseTx Optional IEEE 488.2 GPIB (H x W x L) 40.9 x 212.3 x 379.3 mm 1.61 x 8.36 x 14.93 in Approximate Weight: 3.9 kg, 8.6 lbs. 800x600, 256 colors, CD-ROM drive Software Driver Support for Programming Languages: Software drivers Safety: Conforms to CSA, UL/IEC/EN 61010-1 EMC: Conforms to IEC/EN 61326-1, CISPR 11 * IVI-C and IVI-COM for Windows NT(R)/2000/XP * LabVIEW Compatible with programming tools and environments * Agilent: VEE Pro, T&M Toolkit (reqs Visual Studio.NET) * National Instruments: TestStand, Measurement Studio, LabWindows/CVI, LabVIEW, Switch Executive * Microsoft: Visual Studio.NET (R), C/C++, Visual Basic 6(R) Warranty: 1 year More detailed specifications at www.agilent.com/find/L4400 150 Data Acquisition & Switching Low-Cost Data Acquisition/Switch 34970A 3-slot data acquisition and switching mainframe 61/2 -digit (22 bit) internal DMM 11 built-in measurement functions 8 switch and control plug-in modules 34970A BenchLink data logger software included 34970A Data Acquisition/Switch Unit The Agilent 34970A is a high performance, low-cost data acquisition and switching mainframe ideal for data logging, data acquisition, and general-purpose switching and control applications. It consists of a half-rack mainframe with an internal 61/2 digit (22 bit) digital multimeter. Three module slots are built into the rear of the unit to accept a combination of switch and control modules. Whether you need a few channels of simple data logging or a hundred channels of ATE performance, the 34970A meets your data acquisition needs at a price that meets your budget. Measurements You Can Trust The 34970A incorporates the measurement engine from our best-selling benchtop digital multimeter (DMM). You get the benefit of proven Agilent performance, universal inputs with built-in signal conditioning, and modular flexibility, all in a low-cost, compact data acquisition package. The 34970A features 61/2 digits (22 bits) of resolution, 0.004% basic dcV accuracy, and ultra-low reading noise. Combine that with scan rates of up to 250 channels/sec, and you've got the speed and accuracy you need to get the job done. Custom Configurations That Grow With You Three module slots and eight switch and control modules allow you to customize the 34970A to meet your unique requirements. Buy only what you need, and add more modules later as your application grows. Measure up to 120 inputs with a single half-rack instrument. More detailed specifications at www.agilent.com/find/34970A 151 Data Acquisition & Switching Low-Cost Data Acquisition/Switch 34970A (Continued) Free BenchLink Software Simplifies Your Data Gathering If you want PC-based data logging capabilities, but don't want to spend hours programming, BenchLink Data Logger is the answer. Use it to set up your test, acquire and archive measurement data, and perform real-time display and analysis of the incoming measurements. A familiar spreadsheet environment makes it easy to configure and control your tests. A rich set of colorful graphics provides many options for displaying your data - all with point-and-click ease. Set up multiple graphics using strip charts, histograms, or individual channel results and more. Also use Agilent BenchLink Data Logger to easily move data to other applications for further analysis, or for inclusion in your presentations and reports. Powerful Flexibility The 34970A's unique design allows per-channel configurability for maximum flexibility and quick, easy setup. The internal autoranging DMM measures 11 different functions directly, eliminating the need for expensive external signal conditioning. Temperature conversion routines are built-in to display raw thermocouple, RTD, or thermistor inputs in degrees C, F, or Kelvin. Use Mx+B scaling to convert linear transducer outputs directly into engineering units. You can even set high/low alarm limits to warn you of out-of-tolerance conditions. Applications Data Logging Configured with the 34901A 20-channel relay multiplexer, the 34970A becomes a rugged, low-cost data logger that's ideal for quick tests in the lab or in the field. An intuitive front panel with self-guiding menus and a bright, easy-to-read vacuum fluorescent display make standalone set-up fast and easy. All readings are automatically time stamped and stored in a 50,000 reading memory -- enough memory to hold a week's worth of data (20 channels scanned every five minutes). The non-volatile memory holds your data even after power is removed, so you can use the 34970A to collect data at a remote location for later uploading to a PC. The system configuration is also held in non-volatile memory, so in the event of a power failure the unit automatically resumes scanning when power is returned. And for PC-based testing, Agilent BenchLink Data Logger software is included to simplify your test configurations, data analysis and data management. Automated Testing For automated test and benchtop automation applications, the 34970A's three slots and choice of eight plug-in switch and control modules allow easy customization. The 61/2-digit internal DMM brings you the power and performance of a world-class standalone DMM, but in a fraction of the space and at a fraction of the cost. Software drivers that support Agilent VEE and National Instruments LabVIEWTM are available to make an easy integration of the 34970A into your test system. Standard RS-232 and GPIB interfaces and SCPI programming language make integration even easier. Our proprietary relay maintenance system automatically counts and stores every individual switch closure to help you predict relay end-of-life and avoid costly production line downtime. Module Overview Up to three modules, in any combination, can be inserted into a single mainframe. The 34970A's internal DMM connections are accessible only through the 34901A, 34902A, and 34908A multiplexers. More detailed specifications at www.agilent.com/find/34970A 152 Data Acquisition & Switching Low-Cost Data Acquisition/Switch 34970A (Continued) Module Specifications Module Type Description Connects Speed DMM sec.) Voltage Current Power 34901A 20-ch. Multiplexer 2-wire armature (4-wire selectable) Yes 60 300 V 1A 50 W <3 V 10 MHz 2 current channels (22 ch. Total) Built-in cold junction reference 34902A 16-ch. Multiplexer 2-wire reed Yes (4-wire selectable) 250 300 V 50 mA 2W <6 V 10 MHz Built-in cold junction reference 34903A 20-ch. Actuator/GP Switch SPDT/ form C No 120 300 V 1A 50 W <3 V 10 MHz - 34904A 4 x 8 Matrix 2-wire armature No 120 300 V 1A 50 W <3 V 10 MHz Full crosspoint 34905A Common Low No (unterminated) Dual 1:4 RF Mux, 50 60 42 V 0.7 A 20 W <6 V 2 GHz 1 GHz through provided BNC-to-SMB adapter cables 34906A Common Low No (unterminated) Dual 1:4 RF Mux, 75 60 42 V 0.7 A 20 W <6 V 2 GHz 1 GHz through provided BNC-to-SMB adapter cables 34907A Multifunction Module - 42 V 400 mA - - - - 42 V - - - - 12 V 10 mA - - 60 300 V 1A 50 W <3 V Maximum Input to Internal (ch./ Offset BandVoltage width Comments Switching For test applications that don't require the built-in measurements of the 34970A, the unit can be ordered without the internal DMM. This provides an ultra low-cost solution for routing test signals to and from your device-under-test and assorted instruments, including external DMMs, scopes, counters and power supplies. Plus, you can add the DMM later if your needs change. 34901A 20-Channel general purpose multiplexer Backplane Switches Channel Switches H L Internal DMM Input H L 01 H L 10 H L T 1-wire Yes armature (common low) 10 MHz No 4-wire measurements built-in cold juction reference 34902A 16-Channel multiplexer (2/4-wire) module for 34970A H L H L H L H L Com (4W Sense) 11 20 Backplane Switches Channel Switches H L Internal DMM Input Shunt Switches Fuse T I L I L Internal DMM Input (Current) Open drain Gated; selectable input threshold 100 kHz 16-bit, earth referenced DC Com Bank Switch Reference Junction Sensor Internal DMM Input (4W Sense) 34908A 40-ch. Single-ended Mux Two 8-bit No digital I/O ports 26-bit event - counter Two analog - outputs Fuse I L 22 I L Com (Current) 01 H L 08 H L Com Bank Switch 21 Current Channels H L Reference Junction Sensor H L H L H L H L Com (4W Sense) 09 16 Internal DMM Input (4W Sense) More detailed specifications at www.agilent.com/find/34970A 153 Data Acquisition & Switching Low-Cost Data Acquisition/Switch 34970A (Continued) Accuracy Specifications1 (% of reading + % of range) Includes measurement error, switching error and transducer conversion error 34903A 20-Channel Actuator/GP switch module for 34970A NC COM 01 NO NC COM NO Function Range2 Frequency, etc. 1 Year2 23C 5C DC Voltage 100.0000 mV 1.000000 V 10.00000 V 100.0000 V 300.000 V - - - - - 0.0050 + 0.0040 0.0040 + 0.0007 0.0035 + 0.0005 0.0045 + 0.0006 0.0045 + 0.0030 True RMS AC Voltage3 100.0000 mV to 100.0000 V 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 20 kHz 20 kHz - 50 kHz 50 kHz - 100 kHz 100 kHz - 300 kHz4 1.00 + 0.04 0.35 + 0.04 0.06 + 0.04 0.12 + 0.05 0.60 + 0.08 4.00 + 0.50 300.0000 V 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 20 kHz 20 kHz - 50 kHz 50 kHz - 100 kHz 100 kHz - 300 kHz4 1.00 + 0.08 0.35 + 0.08 0.06 + 0.08 0.12 + 0.12 0.60 + 0.20 4.00 + 1.25 Resistance5 100.0000 1.000000 k 10.00000 k 100.0000 k 1.000000 M 10.00000 M 100.0000 M 1 mA current source 1 mA 100 A 10 A 5.0 A 500 nA 500 nA 10 M 0.010 + 0.004 0.010 + 0.001 0.010 + 0.001 0.010 + 0.001 0.010 + 0.001 0.040 + 0.001 0.800 + 0.010 Frequency and Period 6 100 mV to 300 V 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 40 Hz 40 Hz - 300 kHz 0.10 0.05 0.03 0.01 DC Current (34901A only) 10.00000 mA 100.0000 mA 1.000000 A <0.1 V burden <0.6 V <2 V 0.050 + 0.020 0.050 + 0.005 0.100 + 0.010 True RMS AC Current (34901A only) 10.00000 mA to 1.00000 A 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 5 Hz 1.00 + 0.04 0.30 + 0.04 0.10 + 0.04 100.0000 mA7 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 5 kHz 1.00 + 0.5 0.30 + 0.5 0.10 + 0.5 Temperature Type 1-Year Accuracy8 Thermocouple9 B E J K N R S T 1100C to 1820C -150C + 1000C -150C + 1200C -100C + 1200C -100C + 1300C 300C + 1760C 400C + 1760C -100C + 400C RTD R0 from 49 to 2.1 k -200C + 600C 0.06C Thermistor 2.2 k, 5 k and 10 k -80C to 150C 0.08C 20 1 Specifications are for 1-hour warm-up and 6 1/2 digits, slow AC filter. 2 20% over range on all ranges except 300 Vdc and AC ranges and 1 A DC and AC current ranges. 3 For sinewave input >5% of range. For inputs from 1% to 5% of range and <50 kHz, add 0.1% of range additional error. 4 Typically 30% of reading error at 1 MHz, limited 8 to 1 x 10 V Hz. 5 Specifications are for 4-wire ohms function or 2-wire ohms using scaling to remove the offset. Without scaling, add 4 additional error in 2-wire ohms function. 6 Input >100 mV. For 10 mV inputs, multiply % of reading error x 10. 7 Specified only for inputs >10 mA. 8 For total measurement accuracy, add temperature probe error. 9 Thermocouple specifications not guaranteed when 34907 module is present 1.2C 1.0C 1.0C 1.0C 1.0C 1.2C 1.2C 1.0C See manual or datasheet for more information More detailed specifications at www.agilent.com/find/34970A 154 Data Acquisition & Switching Low-Cost Data Acquisition/Switch 34970A (Continued) Measurement Characteristics DC Voltage Measurement Method A-D Linearity Input Resistance 100 mV, 1 V, 10 V ranges 100 V, 300 V ranges Input Bias Current Input Protection 34904A 4x8 Two-wire matrix module for 34970A Col 1 Col 2 Col 8 H L H L H L True RMS AC Voltage H H L Row 1 H L Row 2 H L Row 3 H L Row 4 Measurement Method Crest Factor Additional Crest Factor Errors (non-sinewave) Input Impedance Input Protection Resistance Measurement Method L Channel 31 (Row 3, Column 1) Crest Factor 1-2 0.05% of reading Crest Factor 2-3 0.15% of reading Crest Factor 3-4 0.30% of reading Crest Factor 4-5 0.40% of reading 1 M 2% in parallel with 150 pF 300 Vrms all ranges Input Protection Measurement Method Voltage Ranges Gate Time Measurement Timeout Reciprocal counting technique Same as AC voltage function 1 s, 100 ms, or 10 ms Selectable 3 Hz, 20 Hz, 200 Hz LF limit DC Current Shunt Resistance Input Protection 5 for 10 mA, 100 mA; 0.1 for 1 A 1 A 250 V fuse on 34901A module True RMS AC Current Measurement Method Shunt Resistance Input Protection Direct coupled to the fuse and shunt, AC coupled True RMS measurement (measures the AC component ony) 5 for 10 mA; 0.1 for 100 mA, 1 A 1 A 250 V fuse on 34901A module Conversion Conformity Reference Junction Type Open Thermocouple Check ITS-90 based software routines Internal, Fixed, or External Selectable per channel, Open >5 k Thermocouple 34906A 75 2 GHz Dual 1:4 Rf MUX, 75 ohm module for 34970A Thermistor 44004, 44007, 44006 series RTD = 0.00385 (DIN) and Measurement Noise Rejection 60 (50) Hz1 12 Com 13 14 21 AC coupled True RMS - measures the AC component of the input with up to 300 Vdc of bias on any range Maximum of 5:1 at full scale Frequency and Period Offset Compensation Maximum Lead Resistance 34905A 50 2 GHz Dual 1:4 Rf MUX, 50 ohm module for 34970A 11 Selectable 10 M or >10.000 M 10 M 1% <30 pA at 25C 300 V all ranges Selectable 4-wire or 2-wire Ohms Current source referenced to LO input Selectable on 100 , 1 k, 10 k ranges 10% of range per lead for 100 and 1 k ranges 1 k on all other ranges 300 V on all ranges L H Continuously integrating multi-slope III A-D Converter 0.0002% of reading + 0.0001% of range DC CMRR AC CMRR 140 dB 70 dB Integration Time 200 plc/3.33 s (4 s) 100 plc/1.67 s (2 s) 20 plc/334 ms (400 ms) 10 plc/167 ms (200 ms) 2 plc/33.3 ms (40 ms) 1 plc/16.7 ms (20 ms) <1 plc Normal Mode Rejection2 110 dB3 105 dB3 100 dB3 95 dB 90 dB 60 dB 0 dB = 0.00391 1 For 1 K unbalance in LO lead 2 For power line frequency 0.1% 3 For power line frequency 1% use 80 dB or 3% use 60 dB 22 Com 23 24 More detailed specifications at www.agilent.com/find/34970A 155 Data Acquisition & Switching Low-Cost Data Acquisition/Switch 34970A (Continued) Operating Characteristics 4 Single Channel Measurement Rates5 Function Resolution9 Reading/s dcV, 2-wire Resistance 6 1/2 digits (10 plc) 51/2 digits (1 plc) 41/2 digits (0.02 plc) 6 (5) 57 (47) 490 Thermocouple 0.1C (1 plc) (0.02 plc) 49 (47) 280 RTD, Thermistor 0.01C (10 plc) 0.1C (1 plc) 1C (0.02 plc) 6 (5) 47 (47) 280 acV 61/2 Slow (3 Hz) 61/2 Med (20 Hz) 61/2 Fast (200 Hz) 61/26 0.14 1 8 100 Frequency, Period 61/2 digits (1s gate) 51/2 digits (100 ms) 41/2 digits (10 ms) 1 9 70 34907A Multifunction module for 34970A Bit 0 8 Port 1 Channel 01 DIO Bit 7 Bit 0 8 Port 2 Channel 02 Bit 7 28 Bits +IN -IN Channel 03 TOT Gate Gate System Speeds 7 16 DAC 1 Channel 04 DAC 2 Channel 05 Channel/s INTO Memory Single Channel dcV 34902A scanning dcV 34907A scanning digital in 34902A scanning dcV with scaling and 1 alarm fail 34907A scanning totalize 34902A scanning temperature 34902A scanning acV 34902A scanning dcV/Ohms on alternate channels 34901A/34908A scanning dcV 16 34908A 40-Channel single-ended multiplexer module for 34970A INTO and OUT of Memory to 34902A scanning dcV GPIB or RS-232 (init/fetch) 34902A scanning dcV with timestamp 180 150 OUT of Memory to GPIB10 Readings Readings with timestamp Readings with all format options ON 800 450 310 OUT of Memory to RS-232 Readings Readings with timestamp Readings with all format options ON 600 320 230 DIRECT to GPIB or RS-232 Single channel dcV 34902A scanning dcV Single channel MEAS DCV10/MEAS DCV 1 Single channel MEAS DCV/MEAS OHMS 440 200 25 12 Channel Switches H 01 H 20 H Com Backplane Switch H 490 250 250 220 170 160 100 90 60 L Com Bank Switch L 4 Reading speeds for 60 Hz and (50 Hz) operation 5 For fixed function and range, readings to memory, scaling and alarms off, AZERO OFF Internal DMM Input H 21 H 40 T 6 Maximum limit with default settling delays defeated 7 Speeds are for 4 1/2 digits, delay O, display off, autozero off, using 115 kbaud RS-232 setting 8 Isolation voltage (ch-ch, ch-earth) 300 Vdc, AC rms 9 6 1/2 digits = 22 bits, 5 1/2 digits = 18 bits, 4 1/2 digits = 15 bits 10 Add 50 uV error for 34923/24/33. Reference Junction Sensor More detailed specifications at www.agilent.com/find/34970A 156 Data Acquisition & Switching Low-Cost Data Acquisition/Switch 34970A (Continued) System Characteristics Scanning Inputs Analog Digital Scan List 34901A, 34902A, and 34908A multiplexer channels 34907A digital in and totalize Scans channels in ascending order Triggering Source Interval, external, button press, software, or on monitor channel alarm 1 to 50,000 or continuous 0 to 99 hours; 1 ms step size 0 to 60 seconds per channel; 1 ms step size <300 s. With monitor on <200 ms <2 ms Scan count Scan interval Channel delay External trig delay External trig jitter Alarms Analog inputs Digital inputs Monitor channel Alarm outputs Latency Hi, Lo, or HI + Lo evaluated each scan 34907A digital in: maskable pattern match or state change 34907A totalize: Hi limit only Alarm evaluated each reading 4 TTL compatible; selectable TTL logic Hi or Lo on fail 5 ms (typical) Memory (Battery backed, 4 year typical life1) Readings States Alarm queue 50,000 with timestamp; Readable during scan 5 instrument states with user label Up to 20 events with channel number, reading, and timestamp System Features Per-channel math Individual Mx + B scaling and Min/Max/Average calculated real time Resumes scanning automatically Counts each relay closure and stores on module. User resettable. Battery-backed, 4 year typical life1 Power fail recovery Relay maintenance Real time clock General Specifications Power supply Power line frequency Power consumption Operating environment Storage environment Weight Safety RFI and ESD 100 V/120 V/220 V/240 V 10% 45 Hz to 66 Hz automatically sensed 12 W (25 VA peak) Full accuracy for 0C to 55C Full accuracy to 80% R.H. at 40C -40C to 70C1 Net: 3.6 kg (8.0 lbs) Conforms to CSA, UL-1244, IEC 1010 Cat 1 CISPR 11, IEC 801/2/3/4 Software Agilent BenchLink Data Logger (not included with Option 001) System Requirements 2 Operating System Controller RAM Disk Space Display Computer Interfaces3 GPIB LAN-to-GPIB USB-to-GPIB Windows 98SE, NT(R) 4.0 SP6a, 2000 SP4, XP SP2, Adobe(R) Acrobat(R) Reader V5.0 or higher (to view documentation) Microsoft(R) Internet Explorer V6.0 or higher (required when using Windows NT) Recommended Pentium(R) 4, 800 MHz or greater, Min: Pentium III, 500 MHz Recommended 256 MB or greater, Min 128 MB Recommend 200 MB, Min 100 MB 800 x 600 resolution, 256 colors Agilent and National Instruments PCI-GPIB E5810A 82357A RS-232 (Serial Port) PC COM 1-4 1 Storage at temperature above 40C will decrease battery life 2 Software provided on CD-ROM and includes utility to create floppy disks for installation 3 Interface and driver must be purchased and installed separately Microsoft, Windows, and Windows NT are U.S. registered trademarks of Microsoft Corporation. Adobe and Acrobat are trademarks of Adobe Systems Incorporated. Pentium is a U.S. registered trademark of Intel Corporation More detailed specifications at www.agilent.com/find/34970A 157 Data Acquisition & Switching Low-Cost Data Acquisition/Switch 34970A (Continued) Ordering Information Agilent Model: Bench Dimensions 34970A 34970A Data Acquisition/Switch Unit Includes internal 61/2 digit DMM, operating and service manuals, test report, power cord, and Quick Start package (includes Agilent Benchlink Data Logger software, RS-232 cable, thermocouple, and screwdriver). Modules are purchased separately and are required to operate. 34970A-001 Delete Internal DMM Same as above but deletes DMM and quick start package Order 34970-80010 to retrofit DMM at a later time 34970A-1CM Rackmount Kit 34970A-0B0 Delete Manual Set 34901A 20-Channel Armature Multiplexer 34902A 16-Channel Reed Multiplexer 34903A 20-Channel Actuator/ General Purpose Switch 34904A 4 x 8 Two-Wire Matrix Switch 34905A Dual 4-Channel RF Multiplexer, 50 Ohms (Includes (10) SMB-to-BNC(f) 50 adapter cables) 34906A Dual 4-Channel RF Multiplexer, 75 Ohms (Includes (10 ) SMB-to-BNC(f) 75 adapter cables) 34907A Multifunction Module 34908A 40-Channel Single-Ended Multiplexer Accessories 34161A Accessory Pouch 34131A Hard Carrying Case E5810A LAN/GPIB Gateway 82357A USB to GPIB Converter 34970-80010 DMM Field Installation Kit (Fully calibrated with Test Report and Quick Start Kit) More detailed specifications at www.agilent.com/find/34970A 158 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A 8-slot mainframe with 19 mix-and-match plug-in modules Up to 560 2-wire multiplexer channels or 1024 matrix cross-points Optional built-in 61/2 digit DMM LAN, USB 2.0, and GPIB connectivity 3 34980A High-performance Unit Provides Low-cost Alternative to PXI/VXI Switch & Measurement Platforms If you use automated test equipment for design validation or manufacturing, you now have a cost-effective alternative to PXI and VXI based test-system platforms. The 34980A multifunction switch/measure unit provides comparable functionality that is much easier to use than PXI and VXI and costs less. The 34980A helps you lower your cost of test and accelerate your test-system integration and development. The 34980A handles system switching up to 20 GHz and provides basic measurements and system control. It also offers DMM measurements, counter/totalizer functionality, digital I/O with pattern capabilities, and analog outputs with basic waveforms - all in one low-cost, compact box. And with its standard connectors, software drivers, computer-standard I/O, and Web browser interface, the 34980A easily integrates into electronic functional test and data acquisition systems. Built in graphical interface LXI class C compliant own configuration. You can buy what you need now and add to it or reconfigure it as your requirements change. Whether you are measuring temperature, AC or DC voltage, resistance, frequency, current, or custom measurements, the 34980A offers the functionality you need in a single box. Switch in different measurements with high-performance signal switching - no external signal conditioning is required. Choose between different switch types and topologies with frequency ranges from DC to 20 GHz. The 34980A offers high-density multiplexers for scanning multiple channels, matrices for connecting multiple points at one time, and general purpose switches for simple control and high power needs. The 34980A also offers flexible choices for system control. You can control external devices such as microwave switches, attenuators, solenoids, and power relays. Or use the digital inputs to sense limitswitch and digital-bus status. The rugged instrument comes with a variety of system-ready features: * Web browser interface shows settings at a glance and provides remote access and control * Self-guiding front panel to configure, troubleshoot or view data * Low EMI and efficient system cooling * Heavy-duty cabling and connection options * Rack mount options * Relay counters help predict end-of-life Flexible Switching, Measurements, and System Control The 34980A accommodates up to 8 plug-in modules to give you the flexibility you need. Choose from 19 different modules to define your More detailed specifications at www.agilent.com/find/34980A 159 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) * In-rack calibration for reduced maintenance time * DMM measurement accuracies include the switch for simple calculations Measurements You Can Trust Get proven performance from Agilent instruments, with the resolution, repeatability, speed, and accuracy you've come to expect. Make system connections easily and quickly with simple, reliable connection options: * Built-in Ethernet, USB 2.0, and GPIB connectivity * Low-cost, standard 50- or 78-pin Dsub connectors and cables * Detachable terminal blocks with strain relief * Mass interconnect solutions The 34980A offers built-in signal conditioning and modular flexibility. When you use it with the internal DMM, you can configure each channel independently for the measurements you choose. It includes a variety of features that give you confidence in your measurements: * 61/2 digits of resolution with .004% of accuracy with DC voltage measurements * Alarms per channel - high limit, low limit, or both * Math functions - use Mx+B for custom linear conversions and converting raw inputs * Built-in thermocouple reference for temperature measurements (34921T) * Time-stamped readings The 34980A also has easier signal routing using four 2-wire internal analog buses. You can route your measurements directly to the internal DMM, or you can connect to external instruments through the analog bus connector on the rear of the mainframe. And since you have four 2-wire buses, you can dedicate one bus for use with the internal DMM and use the other three buses for module extensions or additional signal routing between modules, reducing your wiring needs. The integrated DMM is mounted inside the mainframe and does not consume any of the eight useravailable slots and gives you the flexibility to measure 11 types of inputs: * Temperature with thermocouples, RTDs, or thermistors (with 34921A) * DC and AC voltage * 2- and 4-wire resistance * Frequency and period * DC and AC current Standard Interfaces Take the Hassle Out of Connecting to your PC Standard Ethernet, USB and GPIB Standard interfaces are included in every mainframe. Use one of the interfaces that is already available in your computer, or if you prefer, GPIB is still available. Remote Access and Control The built-in Web browser interface provides remote access and control of the instrument via a Java-enabled browser such as Internet Explorer. Using the Web interface, you can set up, troubleshoot, and maintain your system remotely. * View and modify instrument setup * Open, close, or monitor switches * Send SCPI commands * Define and execute switch sequences * View error queue * Get status reports on relay counts Works With your Choice of Software You can save time and preserve your software and hardware investments. Program directly with SCPI, or use IVI or LabVIEW software drivers that provide compatibility with the most popular development environments and tools. More detailed specifications at www.agilent.com/find/34980A 160 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) Modules at a Glance The 34980A mainframe holds up to eight plug-in modules. Mix and match them to create a custom system to meet your switching and system control needs. You can easily add or replace modules as your needs change. Low Description Frequency Switch Models Max Volts 34921A 40-channel armature multiplexer w/low thermal offset 300 V 1 A 45 MHz 100 <3 V Temperature reference 4 current channels Config as 2- or 4-wire 34922A 70-channel armature multiplexer 300 V 1 A 25 MHz 100 <3 V Config as 2- or 4-wire 34923A 40/80-channel reed multiplexer 150 V 0.5 A 45 MHz 500 <50 V Config as 1-, 2- or 4-wire 34924A 70-channel reed multiplexer 150 V 0.5 A 25 MHz 500 <50 V Config as 2- or 4-wire 34925A 40/80-channel optically 80 V isolated FET multiplexer 1 MHz <3 V Config as 1-, 2- or 4-wire 34931A Dual 4x8 armature matrix 300 V 1 A 30 MHz 100 <3 V Backplane expandable 34932A Dual 4x16 armature matrix 300 V 1 A 30 MHz 100 <50 V Backplane expandable 34933A Dual/Quad 4x8 reed matrix 150 V 0.5 A 30 MHz 500 <3 V Backplane expandable Config as 1- or 2-wire 34937A 28-channel Form C and 4-channel Form A 300 V 1A 250 VAC 5 A 10 MHz N/A <3 V <3 V N/A N/A 34938A 20-channel 5-amp Form A 250 VAC 5 A 1 MHz <3 V N/A 34921A 40-Channel armature multiplexer for 34980A H L H L H L ABus1 I 041 L I 931 H Fuse 043 L I Fuse 044 L I Fuse L H ABus3 921 L H ABus4 922 L H 923 1000 N/A H L H L H L H L H L L NC H L L Comments 34937A 32-Channel Form C/Form A General Purpose Switch for 34980A L Fuse L I 042 ABus2 DMM (SENS) DMM (MEAS) Current L 0.05 A Scan Thermal ch/sec offset 34932A Dual 4x16 Armature Matrix for 34980A H Analog Buses Current Max BW Current (MHz) NO H L 924 Channel 001 (1A form C relay) COM H L H L COM 2 021 026 031 036 022 027 032 037 023 028 033 038 024 029 H 025 L H 035 L L L L H L H L H L H L H L H L ABus1 DMM (MEAS) 921 H L H L H L H L H L H L 922 COM 1 HD* LD 1005 1005 HD* LD 006 HD* LD 011 HD* LD 016 007 012 017 003 008 013 018 004 009 014 019 005 000 015 HD* LD HD* LD ABus2 DMM (SENS NO COM Channel 029 (5A form A relay) ABus3 923 Bank 1 002 Channel 028 (1A form C relay) L H L 34923A 40/80 channel dual multiplexer for 34980A HD* NO COM H 040 Bank 2 001 NC H 039 034 H 030 H ABus4 NO 924 LD COM Channel 032 (5A form A relay) 020 HD* LD HD* LD 1005 1005 1005 1005 911 912 HD* LD HD* ABus1 DMM (MEAS) LD Analog buses 913 HD* LD HD* ABus2 DMM (SENS) LD HD* 914 LD HD* LD HD* LD ABus3 HD* LD ABus4 More detailed specifications at www.agilent.com/find/34980A 161 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) RF and Description Microwave Models Insertion Isolation Freq Loss Range VSWR Input Comments Impedance 34941A Quad 1x4 50 ohm 3 GHz RF multiplexer 0.6 dB >58 dB 3 GHz <1.25 50 @ 1 GHz 34942A Quad 1x4 75 ohm 1.5 GHz RF multiplexer 0.6 dB >60 dB 1.5 GHz <1.35 75 @ 1 GHz 34945A/ 34945EXT Microwave switch/ attenuator driver Can drive up to 64 external switch coils; 32 SPDT switches, 8 multiport switches, 8 attenuators, or your own combination. Expand with additional 34945EXTs. 34946A Dual 1x2 SPDT terminated microwave switch <0.42 dB >85 dB <0.69 dB >67 dB 4 GHz or <1.15 20 GHz <1.30 50 @ 4 GHz @ 20 GHz 34947A Triple 1x2 SPDT unterminated microwave switch <0.42 dB >85 dB <0.69 dB >67 dB 4 GHz 20 GHz 50 @ 4 GHz @ 20 GHz System Control Modules Description Specifications 34950A 64-bit digital I/O with memory and counter Eight 8-bit digital I/O channels with programmable polarity, thresholds up to 5 V, with handshaking protocols and pattern memory. Two 10-MHz frequency counter and programmable clock output to 20 MHz, 34951A 4-channel isolated D/A converter with waveform memory Output DC voltage up to 16 V or DC current up to 20 mA. Output waveforms with a 200 kHz update rate and 16 bits of resolution. Use on-board memory to create point-to-point waveforms with more than 500,000 points. 34952A Multifunction module with 32-bit DIO, 2-ch D/A and totalizer Four 8-bit digital I/O channels, two 12 V analog outputs, and a 100-kHz gated totalizer. 34959A Breadboard module Create your own custom designs with access to the +12 V and +5 V supplies, 16 GPIO ports and 28 relay drive lines. 34941A Quad 1x4 50 ohm 3 GHz multiplexer module for 34980A <1.15 <1.30 34950A 64-bit digital I/O with memory and counter for 34980A Bank 1 Bank 2 INTR 8...% 8...% 101 3494xA 301 102 302 COM COM 103 303 104 304 201 401 202 402 COM COM 203 204 403 Quad 1x4 RF VUX 404 xx ohm 8...% DIO bank 1...8 8...% 32 Bits Counter/ totalizer 1...8 INTR Bit0 ** * Bit7 Bit8 ** * Bit15 Bit16 ** * Bit23 Bit24 ** * Bit31 H0 H1 H2 IN Gate Channel 101 8...% Channel 102 8...% Channel 103 8...% Channel 104 8...% Channel 301 24 Bits DIO bank 2...8 Bit0 * ** Bit7 Bit8 * ** Bit15 Bit16 ** * Bit23 Bit24 * ** Bit31 H0 H1 H2 Clock out Channel 201 Channel 202 Channel 203 Channel 204 CLK 20 MHz - 10 Hz 32 Bits Counter/ totalizer 2...8 IN Gate Channel 302 More detailed specifications at www.agilent.com/find/34980A 162 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) Accuracy Specifications1 (% of reading + % of range) Includes measurement error, switching error and transducer conversion error Function Range2 Frequency, etc. 1 Year2 Tcal 1C DC Voltage (with 34921A/22A/25A/ 31A/32A)10 100.0000 mV 1.000000 V 10.00000 V 100.0000 V 300.000 V - - - - - 0.0050 + 0.0040 0.0040 + 0.0007 0.0035 + 0.0005 0.0045 + 0.0006 0.0045 + 0.0030 True RMS AC Voltage3 100.0000 mV to 100.0000 V 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 20 kHz 20 kHz - 50 kHz 50 kHz - 100 kHz 100 kHz - 300 kHz5 1.00 + 0.04 0.35 + 0.04 0.06 + 0.04 0.12 + 0.05 0.60 + 0.08 4.00 + 0.50 300.0000 V 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 20 kHz 20 kHz - 50 kHz 50 kHz - 100 kHz 100 kHz - 300 kHz6 1.00 + 0.08 0.35 + 0.08 0.06 + 0.08 0.12 + 0.12 0.60 + 0.20 4.00 + 1.25 Resistance7 100.0000 1.000000 k 10.00000 k 100.0000 k 1.000000 M 10.00000 M 100.0000 M 1 mA 1 mA 100 A 10 A 5.0 A 500 nA 500 nA 10 M 0.010 + 0.004 0.010 + 0.001 0.010 + 0.001 0.010 + 0.001 0.010 + 0.001 0.040 + 0.001 0.800 + 0.010 Frequency and Period 8 100 mV to 300 V 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 40 Hz 40 Hz - 300 kHz 0.10 0.05 0.03 0.01 DC Current (34921A only) 10.00000 mA 100.0000 mA 1.000000 A <0.1 V burden <0.6 V <2 V 0.050 + 0.020 0.050 + 0.005 0.100 + 0.010 True RMS AC Current (34921A only) 10.00000 mA and5 1.0 A 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 5 Hz 1.00 + 0.04 0.30 + 0.04 0.10 + 0.04 100.0000 mA9 3 Hz - 5 Hz 5 Hz - 10 Hz 10 Hz - 5 kHz 1.00 + 0.5 0.30 + 0.5 0.10 + 0.5 1 One hour warm-up and a fixed configuration with slow AC filter, sine wave input, and 61/2 digits. Temperature within 5C of temperature at calibration (Tcal between 18-28C). 2 90 minute warm-up and a fixed configuration and 61/2 digits. Temperature within 1C of temperature at calibration (Tcal between 18-28C). 3 Relative to calibration standards 4 20% over range on all ranges except 300 VDC and AC ranges and 1 ADC and AC current ranges 5 For sine wave input > 5% of range. For inputs from 1% to 5% of range and < 50 kHz add 0.1% of range additional error. For AC filter slow. 6 Typically 30% of reading error at 1 MHz, limited to 1 x 108 volt-hertz 7 For 4-wire ohms or 2-wire ohms using scaling to remove offset. Add 4 ohms additional error to 2-wire ohms function without scaling. 34923/24/25/33 have series resistance that may limit low 2-wire ohm measurements. 8 Input > 100 mV. For 10 mV inputs multiply % of reading error x 10. For 1 sec aperture (61/2 digits). 9 Specified only for inputs > 10 mA. For AC filter slow. 10 Add 50 V error for 34923/24/33 More detailed specifications at www.agilent.com/find/34980A 163 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) Temperature Measurement Accuracy 1 (% of reading + % of range) Temperature 1-Year accuracy Type Best Range1 Thermocouple (34921A only, includes cold junction accuracy on terminal block) B E J K N R S T 1100C to 1820C -150C to 1000C -150C to 1200C -100C to 1200C -100C to 1300C 300C to 1760C 400C to 1760C -100C to 400C RTD R0 from 49 to 2.1 k -200C to 600C 0.06C Thermistor 2.2 k, 5 k and 10 k -80C to 150C 0.08C 1 1.2C 1.0C 1.0C 1.0C 1.0C 1.2C 1.2C 1.0C For total measurement accuracy, add temperature probe error Operating Characteristics Single Channel Measurement Rates1,2 Function Resolution Reading/s DCV 4 1/2 digits (0.02 plc) 51/2 digits (1 plc) 81/2 digits (10 plc) 3000 59 6 2-wire Resistance 4 1/2 digits (0.02 plc) 51/2 digits (1 plc) 81/2 digits (10 plc) 2000 58 6 Thermocouple (0.02 plc) 0.1C (1 plc) 2000 59 RTD, Thermistor 1C (0.02 plc) 0.1C (1 plc) 0.01C (10 plc) 1900 58 6 ACV 61/2 Fast (200 Hz) 61/2 Med (20 Hz) 61/2 Slow (3 Hz) 350 350 300 Frequency, Period 41/2 digits (10 ms) 51/2 digits (100 ms) 61/2 digits (1 s gate) 70 9 1 1 Reading speeds for 60 Hz: autozero OFF 2 For fixed function and range, readings to memory, scaling and alrams off, autozero OFF More detailed specifications at www.agilent.com/find/34980A 164 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) Measurement Characteristics DC Voltage True RMS AC Voltage Measurement Method Continuously integrating multi-slope III A-D Converter A-D Linearity 0.0002% of reading + 0.0001% of range on 10 v range Input Resistance 100 mV, 1 V, 10 V ranges 100 V, 300 V ranges Selectable 10 M or >10.000 M 10 M 1% Input Bias Current Input Protection <50 pA at 25C 300 V all ranges Measurement Method AC coupled True RMS - measures the AC component of the input with up to 300 Vdc of bias on any range Crest Factor Maximum of 5:1 at full scale Additional Crest Factor Errors (non-sinewave) Resistance Crest Factor 1-2 0.05% of reading Crest Factor 2-3 0.15% of reading Crest Factor 3-4 0.30% of reading Crest Factor 4-5 0.40% of reading Input Impedance Input Protection 1 M 2% in parallel with 150 pF 300 Vrms all ranges Measurement Method Current source Selectable 4-wire or 2-wire Ohms referenced to LO input Offset Compensation Maximum Lead Resistance Selectable on 100 , 1 k, 10 k ranges 10% of range per lead for 100 and 1 k ranges 1 k on all other ranges Input Protection 300 V on all ranges More detailed specifications at www.agilent.com/find/34980A 165 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) Measurement Characteristics (Continued) Frequency and Period Measurement Method Voltage Ranges Gate Time Measurement Timeout Reciprocal counting technique Same as AC voltage function 1 s, 100 ms, or 10 ms Selectable 3 Hz, 20 Hz, 200 Hz LF limit DC Current Shunt Resistance Input Protection 5 for 10 mA, 100 mA; 0.1 for 1 A 1 A 250 V fuse on 34921A module True RMS AC Current Measurement Method Shunt Resistance Input Protection Direct coupled to the fuse and shunt, AC coupled True RMS measurement (measures the AC component ony) 5 for 10 mA; 0.1 for 100 mA, 1 A 1 A 250 V fuse on 34921A module Conversion Reference Junction Type Open Thermocouple Check ITS-90 software compensation Internal, Fixed, or External Selectable per channel, Open >5 k Thermocouple Thermistor 44004, 44007, 44006 series RTD = 0.00385 (DIN) and Measurement Noise Rejection 60 (50) Hz1 DC CMRR AC CMRR 140 dB 70 dB Integration Time 200 plc/3.33 s (4 s) 100 plc/1.67 s (2 s) 20 plc/333 ms (400 ms) 10 plc/167 ms (200 ms) 2 plc/33.3 ms (40 ms) 1 plc/16.7 ms (20 ms) <1 plc Normal Mode Rejection2 105 dB3 100 dB3 95 dB3 90 dB 85 dB 60 dB 0 dB = 0.00392 1 For 1 K unbalance in LO lead 2 For power line frequency 0.08% 3 For power line frequency 1% use 75 dB or 2.5% use 60 dB System Characteristics Scanning Inputs Analog Digital Scan Triggering Source Scan count Scan interval Channel delay External trig delay External trig jitter 34921A -34922A, 34923A, 34924A, and 34925A multiplexer channels 34950A/52A digital in and totalize Interval, external, button press, software, or on monitor channel alarm 1 to 50,000 or continuous 0 to 99 hours; 1 ms step size 0 to 60 seconds per channel; 1 ms step size <2 ms, With monitor on <200 ms <2 ms More detailed specifications at www.agilent.com/find/34980A 166 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) System Characteristics Alarms Analog inputs Digital inputs Monitor channel Alarm outputs Latency Hi, Lo, or HI + Lo evaluated each scan 34950A/52A digital in maskable pattern match or state change 34950A/52A frequency and totalize, Hi limit only Alarm evaluated each reading 4 TTL compatible; selectable TTL logic Hi or Lo on fail 5 ms (typical) Memory Type Readings States Alarm queue Volatile 500,000 with timestamp; Readable during scan 5 instrument states with user label Up to 20 events with channel number, reading, and timestamp System Features Per-channel math Min/Max/Average Power fail recovery Relay maintenance Individual Mx + B scaling and calculated real time Real time clock General Specifications Power supply Power line frequency Power consumption Operating environment Storage environment Mainframe dimensions Mainframe Weight Module dimensions Safety EMC Warranty Software Save switch states Counts each relay closure and stores on module. User resettable. Battery-backed, 20 year typical life Universal 100 V to 240 V 10% 50-60 Hz 10% automatically sensed 150 VA Full accuracy 0C to 55C Full accuracy to 80% R.H. at 40C IEC 60664-1 pollution degree 1 -40C to 70C1 133 x 426 x 341 mm (5.25" x 18.8" x 14") Full rack, 3 units high 8.6 kg (19.6 lbs) 280H x 170 W x 27D mm (11" x 6.7" x 1") Conforms to CSA, UL/IEC/EN 61010-1 Conforms to IEC/EN 61326-1, CISPR 11 1year Agilent connectivity software included Minimum system requirements (IO) libraries and drivers Agilent IO Libraries Suite 14.2 (E2094N) PC hardware Operating System Computer Interfaces Software driver support for programming languages Compatible with programming tools and environments Intel Pentium100 MHz, 84 MByte RAM 210 MByte disk space Display 800 x 600, 256 colors, CD-ROM Drive Windows(R) 98 SE/NT/2000/XP Standard LAN 10 BaseT/100 BaseTx Standard USB 2.0 IEEE400 2 GPIB Software drivers IVI-C and IVI-COM for Windows NT/2000/XP LabVIEW Agilent VEE Pro, Agilent T&M Tool kit (requires Visual Studio.NET) National Instuments Test Stand, Measurement Studio, LabWindows/CVI LabVIEW, Switch Executive Microwoft Visual Studio.NET, C/C++ Visual Basic 6 1 Storage at temperature above 40C will decrease battery life 2 Load IO libraries version M for Windows NT Support Microsoft, Windows, and Windows NT are U.S. registered trademarks of Microsoft Corporation. More detailed specifications at www.agilent.com/find/34980A 167 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) Ordering Information Modules 34980A Multifunction switch/measure mainframe comes with "DMM" option standard. The mainframe holds up to 8 plug-in modules. Multiplexer Modules Matrix Modules General Purpose/ Actuator Modules RF & Microwave Modules Description 34921A Module Connectors Optional Terminal Blocks, Cables, Connector Kits 40-channel armature multiplexer 2-50 pin Dsub, w/low thermal offset Male (order 34921T for temp reference) 3492xT Terminal block with screw connectors 34923A 40/80-channel reed multiplexer Y1135A - 1.5 m 50 pin M/F Dsub cable 34925A 40/80-channel optically isolated FET multiplexer Y1136A - 3 m 50 pin M/F Dsub cable Y1139A - 50 pin female solder cup connector kit 34922A 70-channel armature multiplexer 34924A 70-channel reed multiplexer 34931A Dual 4X8 armature matrix 34932A Dual 4x16 armature matrix Y1135A - 1.5 m 50 pin M/F Dsub cable 34933A Dual/quad 4x8 reed matrix Y1136A - 3 m 50 pin M/F Dsub cable Y1139A - 50 pin female solder cup connector kit 34937A 32-channel Form C/Form A General purpose switch 34938A 20-channel 5-amp Form A switch Y1136A - 3 m 50 pin M/F Dsub cable Y1139A - 50 pin female solder cup connector kit 34941A Quad 1x4 50-ohm 3 GHz RF multiplexer 10-SMA Requires standard 50 ohm SMA RF cables, adapaters 34942A Quad 1x4 75-ohm 1.5 GHz RF multiplexer 10-Mini SMB Requires mini 75 ohm SMB RF cables, adapters 34945A Microwave switch/ attenuator driver N/A Requires 34945EXT and optional Y1150A-Y1155A distribution boards 34946A Dual 1x2 SPDT terminated microwave switch Option 004: 4 GHz switches installed Option 020: 20 GHz switches installed SMA Requires standard 50 ohm SMA cables and adapters 34947A Triple 1x2 SPDT unterminated microwave switch Option 004: 4 GHz switches installed Option 020: 20 GHz switches installed SMA Requires standard 50 ohm SMA cables and adapters 64-bit digital I/O with memory and counter 2-78 pin Dsub, Female 3495xT Terminal block with screw connectors Y1137A - 1.5 m 78 pin M/F Dsub cable Y1138A - 3 m 78 pin M/F Dsub cable Y1142A - 78 pin male solder cup connector kit 34951A 4-channel isolated D/A converter with waveform memory (DMM option required for calibration) 1-50 pin Dsub, Female 3495xT Terminal block with screw connectors Y1135A - 1.5 m 50 pin M/F Dsub cable Y1136A - 3 m 50 pin M/F Dsub cable Y1141A - 50 pin female solder cup connector kit 34952A Multifunction module with 32-bit DIO, 2-ch D/A and totalizer 34959A Breadboard module 26 & 40 pin internal ribbon cable connections Any terminal block can be used assuming 50 or 78 pin Dsub is used System 34950A Measurement & Control Modules 2-78 pin Dsub, Male 3492xT Terminal block with solder connectors Y1137A - 1.5 m 78 pin M/F Dsub cable Y1138A - 3 m 78 pin M/F Dsub cable Y1140A - 78 pin female solder cup connector kit 2-50 pin Dsub, Male 2-50 pin Dsub, Male 3493xT Terminal block with screw connectors 3493xT Terminal block with screw connectors Y1135A - 1.5 m 50 pin M/F Dsub cable More detailed specifications at www.agilent.com/find/34980A 168 Data Acquisition & Switching Multifunction Switch/Measure Mainframe and Modules 34980A (Continued) Ordering Information Accessories Y1130A Rackmount kit for 34980A, forward or reverse mount (reverse mount requires E3664A rail kit) Order E3663AC rail kit for forward rack mount 34945A Accessories (distribution boards required for control of external switch) 34945EXT External driver for 34945A, one required for each 64 coils - holds 4 distribution boards Thermocouples/Thermistors 34307A 10 pack of J type thermocouples 34308A 5 pack of 10 k thermistors What Ships with a 34980A Y1131A Verification and diagnostic tools for 34980A mainframe and modules Y1150A 34945A distribution boards for 8 N181x SPDT switches 5061-0701 Y1132A Module extender for 34980A Y1151A 34945A distribution board for two 87104x/106x multiport or 87406B matrix switches 34980-906xx Firmware Update Flyer Cables1 (used for direct cable connection to module. Some modules require 2 cables) Y1135A 1.5 m 50 pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1136A 3 m 50 pin Dsub, M/F twisted pair with outer shield cable - 300 V Y1137A 1.5 m 78 pin Dsub , M/F twisted pair with outer shield cable - 300 V Y1138A 3 m 78 pin Dsub, M/F twisted pair with outer shield cable - 300 V Connector Kits1 (used to build custom cables) Y1139A Solder cup connector kit for 34921/23/25/31/32/33/37/38 - 50 pin Dsub female - 125 V Y1140A Solder cup connector kit for 34922/34924 - 78 pin Dsub female - 60 V Y1141A Solder cup connector kit for 34951, 34952 - 50 pin Dsub male - 125 V Y1152A 34945A distribution board for one 87204x/206x or 87606B switch and 2 N181x switches LAN Cross Over Cable E2094-60003 I/O Library Suite CD 8710-0059 Screwdriver 34980-13601 Product CD Manual Set Y1153A 34945A distribution board for two 84904/5/6/7/8 or 8494/5/6 step attenuators Y1154A 34945A distribution board for two 87222 transfer switches and 6 N181x SPDT switches Y1155A 34945A distribution board w/generic screw terminals for driving 16 switch coils Y1157A 9-to-10 pin cable kit for Y1150A, Y1152A, Y1154A - supplies to build 4 cables Y1158A 10-to-10/10-to-14 pin cable kit for Y1153A, Y1154A - supplies to build 2 cables Y1159A 16-to-16 pin cable kit for Y1150A/51A/52A/53A/54A/55A supplies to build 2 cables Y1142A Solder cup connector kit for the 34950A - 78 pin Dsub male - 60 V 1 Module specifications include terminal block. Performance may be degraded when using cables or connector kits. More detailed specifications at www.agilent.com/find/34980A 169 Digital Multimeters, Voltmeters Product Comparison 34405A 34401A 34410A/ 34411A 34420A 3458A 34970A w/ 34901A Type DMM 5 -Digit DMM 6 1/2 -Digit DMM 6 1/2 -Digit Nanovolt / micro-ohm meter 7 1/2 -Digit DMM 8 1/2 -Digit Data Logger/ Scanning DMM 6 1/2 -Digit Basic Measurements DC & AC voltage, DC & AC current, 2-wire resistance, frequency DC & AC voltage, DC & AC current, 2-& 4-wire resistance, frequency & period DC & AC voltage, DC & AC current, 2-& 4-wire resistance, frequency & period DC voltage, 2-& 4-wire resistance, low power resistance, ratio DC & AC voltage, DC & AC current, 2-& 4-wire resistance, frequency & period DC & AC voltage, DC & AC current, 2-& 4-wire resistance, frequency & period Additional Measurements continuity, diode test, capacitance continuity, diode test continuity, diode 2 channels test, capacitance, ratio and data logger, and difference waveform capture 3 modes of true Scanning RMS, Digitizing 20 to 60 2-wire channels Temperature Thermistor N/A Thermistor, RTD Direct SPRT, RTD, Thermistor, Thermocouple Thermistor, RTD Thermocouple, RTD, Thermistor dcV Accuracy1 (% of reading + % of range) 0.025 + 0.005 0.0035 + 0.0005 0.0030 + 0.0005 0.003 + 0.0004 0.0008 + 0.000005 0.0035 + 0.0005 (.0004 + .000005) 2 Math Functions Null, min/max, dBm, dB, limit test, hold Null, statistics, dBm, dB, limit test Null, statistics, dBm, dB, limit test Null, statistics, dBm, dB, limit, scale, offset, filter, moving avg. filter Null, statistics, Null, statistics, dBm, dB, limit limit test, scale, test, scale, offset, offset filter, % error Connectivity USB 2.0 GPIB, RS232, Optional USB w/82357A GPIB, USB 2.0 and LAN LXI class C standard GPIB, RS232, Optional USB w/82357A GPIB, Optional USB w/ 82357A Includes IntuiLink SW Includes Includes IntuiLink SW IntuiLink SW and LXI Web browser GPIB, RS232, Optional USB w/82357A Includes BenchLink Data Logger SW 1 dcV accuracy; 1yr, 10 V range 2 dcV accuracy with optional high stability reference (option 3458-002) More detailed specifications at www.agilent.com/find/DMM 170 Digital Multimeters 51/2 -Digit Low-Cost Multimeter 34405A 3 34405A Agilent 34405A 51/2 -Digit Low-Cost DMM * 120,000 counts resolution * 16 built-in measurement functions including temperature and capacitance * 0.025% 1-year DC voltage accuracy * USB 2.0 * SCPI compatible * Agilent IO Libraries Suite and DMM IntuiLink connectivity software included Affordable and Feature-Rich Measurement Tool The 34405A is the latest addition to Agilent's DMM family, and it offers you another choice for making electronics measurements. The 34405A provides a broad range of measurement functions and features such as DC voltage, DC current, true-RMS AC voltage and AC current, 2-wire resistance, frequency, diode test and continuity measurement functions, all designed to meet your general industrial needs. Further evidence of its true value is its ability to measure capacitance from 1,000 pF to 10,000 F. With its six built-in math operations -- Null, dBm, dB, MinMax, Limit and Hold -- the Agilent 34405A improves your efficiency and accuracy. Quick Connect to PC with USB 2.0 Interface If you need to control your DMM and take preset measurements through a PC, use the built-in USB 2.0 interface, which provides an easy and robust connection between the PC and the DMM. Compliant with the TMC-488.2 standard, the USB interface works seamlessly with Agilent connectivity software, and it can be controlled remotely with industry-standard SCPI commands or through DMM IntuiLink connectivity software. IVI-COM and LabVIEW drivers are included to ensure easy integration with different programming environments. Bright Display, High Reading Speed and Configuration Storage When higher productivity and throughput are a priority, the Agilent 34405A VFD dual display allows you to take multiple measurements and display them simultaneously on the front panel. For speed-critical applications, the Agilent 34405A can take up to 19 readings/s at 4.5 digits direct to a PC. You also can configure and store complete instrument setups and recall them anytime from any one of four built-in storing states. Rugged and Reliable The 34405A was designed and tested according to major safety and regulatory standards. Its shock-absorbing bumpers prevent physical damage from your day-to-day use. More detailed specifications at www.agilent.com/find/34405A 171 Digital Multimeters 51/2 - Digit Multimeter 34405A (Continued) Operating Characteristics Digits Function Measurement Characteristics DC Voltage Measurement Method: Reading 1 Speed System Speed Function Change (S)2 Range Change (S)3 Auto Range (S)4 Reading Speed Over USB (S)5 DCV, DCI 5 1/2 4 1/2 15/s 70/s 0.6 0.7 2.2 8/s 19/s ACV, ACI 5 1/2 4 1/2 2.5/s 5.0 2.2 6.1 1/s Frequency 5 1/2 4 1/2 2/s 7.0 2.5 6.1 1/s Sigma delta A-to-D converter 10 M 2% range (typical) 1 Reading rate of the A/D converter 2 Time to change from 2-wire resistance to this specified function and to take at least one reading in 4.5-digit mode Input Protection: 3 Time to change one range to the next higher range and to take at least one reading in 4.5-digit mode using the Input Resistance: using the SCPI "FUNC" and "READ?" commands 1000 V on all ranges SCPI "FUNC" and "READ?" commands 4 Time to automatically change one range and to take at least one reading in 4.5-digit mode using SCPI "CONF AUTO" Resistance Measurement Method: and "READ?" commands 5 Number of measurements per second that can be read through USB using SCPI "READ?" command 2-wire ohms Open-Circuit Voltage: Limited to < 5 V DC Characteristics1 Accuracy (% of Reading + % of Range) Input Protection: 1000 V on all ranges Range2 Function Test Current or Burden Voltage Input Impedence3 1 Year 23C 5C Temp. Coefficient 100.000 mV -- 10.0 M 2% 0.025+0.008 0.0015+0.0005 1.00000 V -- 10.0 M 2% 0.025+0.006 0.0010+0.0005 10.0000 V -- 10.1 M 2% 0.025+0.005 0.0020+0.0005 100.00 V -- 10.1 M 2% 0.025+0.005 0.0020+0.0005 1000.0 V -- 10.0 M 2% 0.025+0.005 0.0015+0.0005 100.000 1.0 mA -- 0.05+0.008 4 0.0060+0.0008 1.00000 k 0.83 mA -- 0.05+0.0054 0.0060+0.0005 10.0000 k 100 A -- 0.05+0.0064 0.0060+0.0005 Continuity/Diode Test 100.000 k 10.0 A -- 0.05+0.007 0.0060+0.0005 Measurement Method: 1.00000 M 900 nA -- 0.06+0.007 0.0060+0.0005 Uses 0.2% constant current source, < 5 V open circuit voltage 10.0000 M 205 nA -- 0.25+0.005 0.0250+0.0005 100.000 M 205 nA||10 M -- 2.00+0.005 0.3000+0.0005 DC Current Shunt Resistance: 0.1 to 10 for 10 mA to 1.2 A ranges 0.01 for 12 A range Input Protection: Front panel fuse for I terminal; Internal 15 A, fuse for 12 A terminal Voltage Resistance 10.0000 mA < 0.2 V -- 0.05+0.015 0.0055+0.0005 70 samples/s with audible tone 100.000 mA < 0.2 V -- 0.05+0.005 0.0055+0.0005 Continuity Threshold: 10 fixed 1.00000 A < 0.5 V -- 0.20+0.007 0.0100+0.0005 10.0000 A < 0.6 V -- 0.25+0.007 0.0150+0.0005 1000 0.83 mA -- 0.05+0.005 0.0050+0.0005 1.0000 V 0.83 mA -- 0.05+0.005 0.0050+0.0005 Response Time: Input Protection: 1000 V Current 0C - 18C 28C - 55C Continuity Diode Test 5 1 Specifications are for 30 minutes warm-up, 5 1/2 digit resolution and calibration temperature 18C to 28C. 2 20% over range on all ranges except 1000 VDC 3 Input impedence is in parallel with capacitance < 120 pF 4 Specifications are for 2-wire ohms using Math Null. Without Math Null, add 0.2 additional error. 5 Specifications are for the voltage measured at the input terminals only. More detailed specifications at www.agilent.com/find/34405A 172 Digital Multimeters 51/2 - Digit Multimeter 34405A (Continued) AC Characteristics1 Accuracy (% of Reading + % of Range) Range2 Function Temperature Measurement Method: True RMS 3 AC Voltage 2-wire ohms measurement of 5 k thermistor sensor (YSI 4407) with computer conversion auto-ranging measurement, no manual range selection Frequency 100.000 mV 1 Year 23C 5C 1.0+0.1 0.02+0.02 45 Hz - 10 kHz 0.2+0.1 0.02+0.02 10 kHz - 30 kHz 1.5+0.3 0.05+0.02 5.0+0.3 0.10+0.02 20 Hz - 45 Hz 1.0+0.15 0.02+0.02 45 Hz - 10 kHz 0.2+0.1 0.02+0.02 10 kHz - 30 kHz 1.0+0.1 0.05+0.02 3.0+0.2 6 0.10+0.02 30 kHz - 100 kHz Input Protection: 1000 V True-RMS 7 0C - 18C 28C - 55C 20 Hz - 45 Hz 30 kHz - 100 kHz 1.00000 V to 750.00 V Temp. Coefficient 4 4 10.0000 mA 20 Hz - 45 Hz 1.5+0.1 0.02+0.02 Measurement Noise Rejection 100.000 mA 45 Hz - 1 kHz 0.5+0.1 0.02+0.02 CMRR (Common Mode Rejection): 10.0000 A 1 kHz - 10 kHz 100 mV to 750 V < 2 Hz For 1 k unbalance LO lead DC 120 dB AC 70 dB Frequency 9 < 20 Hz 20 Hz ~ 100 kHz 10 mA to 10 A For 60 Hz (50 Hz) 0.1% 5 1/2 digits 65 dB (55 dB); 4 1/2 digits 0 dB Measurement Method: AC coupled true-rms - measure the AC component with up to 400 VDC bias any range Crest Factor: 10 100 kHz ~ 300 kHz NMR (Nomal Mode Rejection): AC Voltage 8 11 2.0+0.2 0.02+0.02 0.18+0.003 0.005 0.04+0.003 0.005 0.02+0.003 0.005 0.02+0.003 0.005 < 2 Hz 0.18+0.003 0.005 < 20 Hz 0.04+0.003 0.005 0.02+0.003 0.005 20 Hz ~ 10 kHz 11 Temperature and Capacitance Characteristics 1 Accuracy (% of Reading + % of Range) Function Temperature Maximum 5:1 at full scale Capacitance Range Test Current, Etc. 1 Year 23C 5C Temp. Coefficient 0C - 18C 28C - 55C -80.0 C - 150C 5 k thermistor probe Probe accuracy + 0.2 C 0.002 C -110.0 F - 300.0F 5 k thermistor probe Probe accuracy + 0.4 F 0.0036F 1.000 nF 0.75 A 2.0+0.8 0.02+0.001 10.00 nF 0.75 A 1.0+0.5 0.02+0.001 100.0 nF 8.3 A 1.0+0.5 0.02+0.001 1.000 F - 100.0 F 83 A 1.0+0.5 0.02+0.001 Input Protection: 1000 F 0.83 mA 1.0+0.5 0.02+0.001 750 Vrms on all ranges 10,000 F 0.83 mA 2.0+0.5 0.02+0.001 Input Impedance: 1 M 2% in parallel with < 100 pF of all ranges 1 Specifications are for 30 minutes warm-up, 5 1/2 digit resolution and calibration temperature 18 C - 28 C. 2 20% over range on all range except 750 Vac 3 Specifications are for sinewave inputs > 5% of range. Maximum crest factor: 3 at full scale. 4 Additional error to be added as frequency > 30 kHz and signal input < 10% of range 30 kHz ~ 100 kHz: 0.003% of full scale per kHz 5 For input < 200 Vrms 6 For input < 300 Vrms 7 For 12 A terminal, 10 A DC or AC rms continuous, > 10 A DC or AC rms for 30 seconds on and 30 seconds off 8 For 1 A and 10 A ranges, the frequency is verified for less than 5 kHz. 9 Specifications are for half-hour warm-up, using 0.1 second aperture. The frequency can be measured up to 1 MHz as 0.5 V signal to 100 mV/1 V ranges. 10 For 20 Hz ~ 10 kHz, the sensitivity is AC input current from 10% to 120% of range except where noted. 11 For 100 kHz ~ 300 kHz, the sensitivity will be 12% ~ 120% of range except 750 V range. More detailed specifications at www.agilent.com/find/34405A 173 Digital Multimeters 51/2 - Digit Multimeter 34405A (Continued) Agilent Model: Systems Dimensions 34405A AC Current Measurement Method: DC coupled to the fuse and current shunt, AC coupled true rms measurement (measure the AC component only) Agilent Technologies Shunt Resistance: 0.1 to 10 for 10 mA to 1.2 A range 0.01 for 12 A range 261.1mm Input Protection: Externally accessible 1.5-A, 250-V fuse for 1 terminal Internal replaceable 15-A, 500-V fuse for 12 A terminal 103.8mm Frequency Measurement Method: 303.2mm Reciprocal counting technique AC-coupled input using AC voltage function Signal Level: 10% of range to full scale input on all ranges Auto or manual range selection General Specifications Measurement Category: Power Supply: CAT II, 300 V: CAT I 1000 VDC, 750 Vrms, 2500 Vpk transient over voltages Pollution degree 2 0.1 second or 1 period of the input signal, whichever is longer 100 V/120 V(127 V) / 220 V (230 V) / 240 V 10% AC line frequency 45 Hz - 66 Hz and (360 Hz - 440 Hz, 100/120 V operation) Input Protection: Power Consumption Certified to IEC/EN 61326: 2002, CISPR 11, for Group 1, Class A 750 Vrms on all ranges 16 VA maximum, <11 W average Shock and Vibration Math Functions Null, dBm, dB, Min/Max/Avg, Hold, Limit Test Operating Enviroment Tested to IEC/EN 60086-2 Gate Time: Triggering and Memory Single trigger, 1 reading memory Remote Interface USB 2.0 full speed, USBTMC class device (GPIB over USB) Programming Language SCPI, IEEE-488.1, IEEE-488.2 Full accuracy at 0C to 55C Full accuracy to 80% RH at 30C (non-condensing) Altitude up to 3000 meters EMC Compliance Dimension (H x W x D): Storage Compliance Temperature Rack: 88.5 mm x 212.6 mm x 272.3 mm Bench: 103.8 mm x 261.1 mm x 303.2 mm -40C to 70C Weight: 3.75 kg, 8.27 lb Safety Compliance Warm up Time: 30 minutes Certified by CSA for IEC/EN/CSA/UL 61010-1 2nd Edition Warranty: 1 year More detailed specifications at www.agilent.com/find/34405A 174 Digital Multimeters Low-Cost 61/2 -Digit Multimeter 34401A 34401A 34401A Digital Multimeter The 34401A digital multimeter establishes a new price/performance standard by offering such features as 6 1/2 digits of reolution, 1000 readings per second, and 15 ppm basic DC accuracy at a surprisingly affordable price. The 34401A has been designed for superior performance while providing the flexibility to meet both your present and future needs. Great Bench Performance The clear, logical front panel of the 34401A allows you to easily select all primary measurement functions. Traditional "bench" functions, such as continuity and diode test, are included. Math functions, such as NULL, dB, dBm, limit test, and min/max/avg are easily selected. A simple menu scheme gives you access to powerful advanced features, such as the ability to store up to 512 readings in internal memory. Measurement results are displayed on a bright, high-visibility readout. A rugged case ensures survival even under the toughest conditions, and the optional accessory pouch makes it easy to pack up and go with the 34401A. 12 measurement functions GPIB and RS-232 standard 1000 V maximum input 512-reading memory 35 ppm basic dcV accuracy (1-year) 3 Hz to 300 kHz AC bandwidth 1000 readings per second direct to GPIB IntuiLink Connectivity Software included Superior Performance in Your System The 34401A can take up to 1000 readings per second, including GPIB bus transfer in ASCII format. Both GPIB and RS-232 are standard, letting you select the interface that best meets your needs. 34401A responds to three different command languages. It accepts SCPI commands (Standard Commands for Programmable Instruments), which ensures present and future compatibility. Drivers are also available for both National Instruments Labview and Agilent's VEE software. IntuiLink Software, included with your 34401A, allows you to transfer your measurement data and images into Microsoft Excel or Microsoft Word with little or no programming. You can specify the meter setup and take a single reading or log data to the Excel spreadsheet in specific time intervals. Programmers can use the ActiveX components to control the DMM using SCPI commands. To find out more about IntuiLink, visit www.agilent.com/find/intuilink Application Information Optimizing System Design for Rapid Development, Fast Execution and Re-use Application Note 1481 5989-0154EN Techniques to Minimize Overall Test Time When Using a DMM and Switch System Application Note 1479 5989-0150EN Making High Accuracy Temperature Measurements with the 3499A/B/C Switch and the 34401A Digital Multimeter Application Note 1460 5988-9550EN Digital Multimeter Measurement Errors Series System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters Application Note AN 1389-1 5988-5511EN Digital Multimeter Measurement Errors Series Resistance; DC Current; AC Current; and Frequency and Period Measurement Errors in Digital Multimeters Application Note AN 1389-2 5988-5512EN More detailed specifications at www.agilent.com/find/34401A 175 Digital Multimeters Low-Cost 61/2 -Digit Multimeter 34401A (Continued) Low Cost 6 1/2 Digital Multimeter - Abbreviated Technical Specifications DC Voltage Input Characteristics Range Maximum Reading (6 1/2 digits) Resolution in Digits 6 1/2 5 1/2 4 1/2 100 mV 120.0000 100 V 1 V 10 V 10 M or >10 G 1V 1.200006 1 V 10 V 100 V 10 M or >10 G Power Consumption: 25 VA peak (10 W average) 10 V 12.00000 10 V 100 V 1 mV 10 M or >10 G 100 V 120.0000 100 V 1 mV 10 mV 10 M Operating Environment: 0 to 55C, full accuracy to 80% RH, 40C 1000 V 1050.000 1 mV 10 mV 100 mV 10 M General Specifications: Power: 100/120/220/240V, 10% Power Line Frequency: 45 to 66 Hz, 360 to 440 Hz Input Resistance Input Protection: >1000 V on all ranges Storage Environment: -40C to 70C Size: 88.5 mm H x 212.6 mm W x 348.3 mm D (4 in x 8.5 in x 14 in) Measurement Accuracy: (% of reading + % of range) Range 24 Hour 23C 1C 90 Day 23C 1C 1 Year 23C 1C 100 mV 0.0030 + 0.0030 0.0040 + 0.0035 0.0050 + 0.0035 1V 0.0020 + 0.0006 0.0030 + 0.0007 0.0040 + 0.0007 Order Information: 10 V 0.0015 + 0.0004 0.0020 + 0.0005 0.0035 + 0.0005 34401A Multimeter 34401A-1CM Rackmount Kit 34401A-A6J ANSI Z540 Compliant Calibration 100 V 0.0020 + 0.0006 0.0035 + 0.0006 0.0045 + 0.0006 1000 V 0.0020 + 0.0006 0.0035 + 0.0010 0.0045 + 0.0010 6 1/2 5 1/2 4 1/2 60 Hz 6 300 1000 50 Hz 6 300 1000 Weight: Net 3.6 kg (8.0 lb); shipping 5.9 kg (13 lb) Safety: Designed to UL-1244, IEC-348, CSA 34161A Accessory Pouch 34171A Input Terminal Connector (sold in pairs) 34172A Input Calibration Short (sold in pairs) 34131A Hard Transit Case Maximum Reading Rate: (readings/s) Power Line Frequency Resolution in Digits AC Voltage (true rms) Measurement Accuracy: (% of reading + % of range); 1 year, 23C + 5C Frequency Ranges 100 mV Ranges 1, 10, 100, 750 V 3 to 5 Hz 1.00 + 0.04 1.00 + 0.03 5 to 10 Hz 0.35 + 0.04 0.35 + 0.03 10 Hz to 20 kHz 0.06 + 0.04 0.06 + 0.03 20 to 50 kHz 0.12 + 0.04 0.12 + 0.05 50 to 100 kHz 0.60 + 0.08 0.60 + 0.08 100 to 300 kHz* 4.00 + 0.50 4.00 + 0.50 *Typically 30% of reading error at 1 MHz More detailed specifications at www.agilent.com/find/34401A 176 Digital Multimeters Low-Cost 61/2 -Digit Multimeter 34401A (Continued) Low Cost 6 1/2 Digital Multimeter - Abbreviated Technical Specifications (Continued) Resistance: (2-wire , 4-wire )Input Characteristics Range 254.4 mm Maximum Reading (6 1/2 digits) Resolution in Digits 6 1/2 5 1/2 4 1/2 100 1 k 120.0000 1.200000 100 1 m 1 m 10 m 10 m 100 m 10 k 12.00000 10 m 100 m 1 100 k 120.0000 100 m 1 10 1 M 1.200000 1 10 100 10 M 12.00000 10 100 1 k 100 M 120.0000 100 1 k 10 Input Protection: >1000 V on all ranges 212.6 mm Measurement Accuracy: (% of reading + % of range) Specs are for 4-wire or 2-wire using Math Null 103.6 mm 374.0 mm 88.5 mm Range 24-Hour 23C 1C 90-Day 23C 5C 1-Year 23C 5C Shunt Resistance 100 0.0030 + 0.0030 0.008 + 0.004 0.010 + 0.004 1 mA 1 k 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 1 mA 10 k 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 100 A 100 k 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 10 A 1 M 0.0020 + 0.001 0.008 + 0.001 0.010 + 0.001 5.0 A 10 M 0.0150 + 0.001 0.020 + 0.001 0.040 + 0.001 500 nA 100 M 0.3000 + 0.010 0.800 + 0.010 0.800 + 0.010 500 nA* Maximum Reading Rate: Same as dcV 348.3 mm DC Current Measurement Accuracy: (% of reading + % of range) Range 24-Hour 23C 1C 90-Day 23C 5C 1-Year 23C 5C Shunt Resistance 10 mA 0.005 + 0.010 0.030 + 0.020 0.050 + 0.020 500 100 mA 0.010 + 0.004 0.030 + 0.005 0.050 + 0.005 5.0 1A 0.050 + 0.006 0.080 + 0.010 0.100 + 0.010 0.1 3A 0.100 + 0.020 0.120 + 0.020 0.120 + 0.020 0.1 Input Protection: Externally accessible 3 A 250 V fuse; internal 7 A 500 V fuse Maximum Reading Rate: Same as dcV AC Current (true rms): Measurement Accuracy: (% of reading + % range); 1 year, 23C 5C Frequency Ranges 1A Ranges 3A 3 to 5 Hz 1.00 + 0.04 1.10 + 0.06 5 to 10 Hz 0.30 + 0.04 0.35 + 0.06 10 Hz to 5 kHz 0.10 + 0.04 0.15 + 0.06 Input Protection: Externally accessible 3 A 250 V fuse; internal 7 A 500 V fuse Maximum Reading Rate: Same as dcV More detailed specifications at www.agilent.com/find/34401A 177 Digital Multimeters 61/2 -Digit High Performance Multimeters 34410A and 34411A 3 34410A and 34411A Agilent 34410A 61/2 -Digit High-Performance DMM * 10,000 readings/s @ 5 1/2 digits direct to PC * 1,000 readings/s @ 6 1/2 digits direct to PC * 30 PPM 1 year Basic DC accuracy * LAN, USB & GPIB standard * DCV, ACV, DCI, ACI, 2-wire and 4-wire Resistance, Frequency, Period, Continuity, and Diode Test * Capacitance & Temperature measurements * Expanded measurement ranges * Data logger with 50 k reading Non-volatile memory * LXI class C compliant Agilent 34411A 61/2 -Digit Enhanced-Performance DMM All the features of the 34410A, plus: * 50,000 readings/s @ 41/2 digits direct to PC * 1 Million reading memory * Analog level triggering * Programmable Pre/Post triggering * LXI class C compliant The Best Just Got Better The Agilent 34410A and 34411A 61/2 - Digit DMMs represent the latest generation of multimeters from Agilent Technologies. Building on the success of the industry-standard Agilent 34401A, these new meters offer improved accuracy, expanded measurement capability, dramatically improved measurement speed and throughput, and modern computer interfaces including LAN and USB. The dual display offers both dual measurement capabilities and ease of use when setting up and configuring the DMM. Improvements have been made in every facet of the 34401A to make the best even better, whether you use it on the bench or in a system. Dramatic Speed Improvements Whether it's raw reading speed or fast system throughput, the 34410A sets a new benchmark in performance. Using a new A/D technology, the 34410A achieves an impressive 10,000 readings a second at 5 1/2 digits, and can stream readings to your computer at this same speed! Triggering is fast and precise, with both trigger latency and trigger jitter less than 1 s, while bus query response is less than 500 s. ACV measurements are faster as well thanks to a digital measurement technique that additionally improves accuracy at high and low frequencies. For even greater reading speeds, select the 34411A, which achieves 50,000 DCV readings a second at 4 1/2 digits. Enhanced Measurement Performance The 34410A and 34411A offer Temperature and Capacitance capabilities, in addition to those measurements you have come to expect, such as DCV, ACV, DCI, ACI, 2-wire and 4-wire Resistance, Frequency, Period, Continuity and Diode Test. You also get Offset Compensated Ohms, allowing you to accurately measure resistance in the presence of voltages. Measurement ranges have been expanded as well; for example, DC and AC Current Ranges now go down to 100 A, resulting in 100 pA resolution. Real-time math and statistics are included, and a peak-detect capability allows you to capture peaks as short as 20 s. Even Greater Performance with the 34411A The 34411A has all the features of the 34410A, plus additional performance that makes it even more powerful. With the ability to make 50,000 readings per second at 4 1/2 digits, Analog Level Triggering, programmable Pre- and Post- Trigger and 1 million readings of volatile memory in addition to 50,000 reading of non-volatile memory, you now have the ability to capture low-frequency waveforms, characterize device performance and transfer results for analysis on your computer. More detailed specifications atwww.agilent.com/find/34410A 178 Digital Multimeters 61/2 - Digit Multimeters 34410A-34411A (Continued) Measurement Characteristics DC Voltage Measurement Method: Continuously integrating multi-slope IV A/D converter Linearity: 0.0002% of reading + (10 V range) + 0.001% of range Input Resistance: 0.1 V, 1 V, 10 V range 10 M or > 10 G 100 V, 1000 V range 10 M 1% Input Bias Current: < 30 pA at 25C Input Protection: 1000 V DC CMRR: 140 dB1 True RMS AC Voltage Measurement Method: AC-coupled True RMS measurement. Digital sampling with anti-alias filter. Crest Factor: No additional error for crest factors <10. Limited by peak input and 300 kHz bandwidth. Peak Input: 300% of range or 1100 Vpk Overload Ranging: Will select higher range if peak input overload is detected during auto range. Overload is reported in manual ranging. AC CMR: 70 dB2 Maximum Input: 400 Vdc, 1100 Vpk Input Impedance: 1 M 2% in parallel with < 150 pF Resistance Frequency and Period Measurement Method: Measurement Method: Selectable 2-wire or 4-wire. Current source referenced to LO input. Reciprocal-counting technique. AC-coupled input using the AC voltage measurement function. Offset Compensation: Selectable on the 100 , 1 k, and 10 k ranges Input Impedance: Max. Lead Resistance (4-wire): Input Protection: 10% of range per lead for 100 , 1 k. 1 k per lead on all other ranges. 750 Vrms all ranges Input Protection: Measurement Method: 1 M 2% in parallel with <150 pF Capacitance 1000 V on all ranges Current input with measurement of resulting ramp. DC Current Connection Type: Current Shunt: 2-wire 200 for 100 A, 1 mA 2 for 10 mA, 100 mA 0.1 for 1 A, 3 A Temperature Thermistor: Input Protection: 2.2 k, 5 k, and 10 k 3 A, 250 V fuse RTD: True RMS AC Current = 0.00385, Ro from 49 to 2.1 k Measurement Method: AC-coupled True RMS measurement. Directly coupled to the fuse and shunt. Digital sampling with anti-alias filter. Continuity/Diode Test Response Time: 300 samples/sec with audible tone Continuity Threshold: Fixed at 10 Current Shunt: 200 for 100 A, 1 mA 2 for 10 mA, 100 mA 0.1 for 1 A, 3 A Operating Characteristics- Maximum readindgs/second Digits Maximum Input: Function3 4.5 5.5 6.5 The peak value of the DC + AC current must be <300% of range. The RMS current must be < 3 A including the DC current content. DCV 50 k4 10 k 1k 2-wire 25 k4 3k 60(50) DCI 3k 60(50) 60(50) ACV 500 500 150 ACI 500 150 150 Frequency 450 90 10 Period 450 90 10 Input Protection: Input Protection: 750 Vrms all ranges 3 A, 250 V fuse 1 For 1 k unbalanced in LO lead, 3 Maximum rate for DCV, DCI, and resistance 500 V peak maximum 2 For 1 k unbalanced in LO lead and < 60 Hz, 500 V peak maximum functions (using zero settling delay, autozero off, manual range) 4 34411A only More detailed specifications atwww.agilent.com/find/34410A 179 Digital Multimeters 61/2 - Digit Multimeters 34410A-34411A (Continued) Triggering and Memory General Specifications Safety: Reading Hold Sensitivity: Power Supply: 1% of reading 100 V/120 V/220 V/240 V 10% Samples per Trigger: Power Line Frequency: 1 to 50,000 1 to 1,000,000 45 Hz to 66 Hz and 360 Hz to 440 Hz, automatically sensed at power-on IEC 61010-1, EN 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1, Refer to Declarations of Conformity for current revisions. Measurement CAT II 300V, CAT I 1000V. Pollution Degree 2 Trigger Delay: Power Consumption: EMC: 0 to 3600 sec (20 s step size) 25 VA peak (16 W average) External Trigger: Operating Environment: Programmable edge, Low-power TTL compatible Delay: < 1 s Jitter: < 1 s Max rate: up to 5,000/sec Min Pulsewidth: 1 s Full accuracy for 0C to 55C, 95% R.H. at 40C Non-condensing IEC 61326, EN 61326, CISPR 11, ICES-001, AS/NZS 2064.1, Refer to Declaration of Conformity for current revisions. Storage Temperature: Vibration & Shock: (34410A) (34411A) MIL-T-28800E, Type III, Class 5 (Sine Only) -40C to 70C Weight: 3.72 kg (8.2 lbs) Warranty: 1 year Voltmeter Complete: 3 V Logic output, 2 s pulse with programmable edge Agilent Model: Bench Dimensions 34410A, 34411A Nonvolatile Memory: 50,000 readings Volatile Memory: 50,000 readings (34410A) 1,000,000 readings (34411A) 13.8cm Sample Timer: Range: Up to 3600 sec (20 s step size) Jitter: < 100 ns 261.2cm 303.2cm Agilent Model: Systems Dimensions 34410A, 34411A 88.3cm 212.6cm 272.2cm More detailed specifications atwww.agilent.com/find/34410A 180 Digital Multimeters 61/2 - Digit Multimeters 34410A-34411A (Continued) Specifications Range3 (% of reading + % of range) DC Voltage True RMS AC Voltage5 Resistance6 DC Current True RMS AC Current 7 Frequency or Period Capacitance8 24 Hour 2 Tcal 1C Frequency, Test Current or Burden Voltage 90 Day Tcal 1C 1 Year Tcal 5C Temp.Coef. 0C to (Tcal - 5C) (Tcal + 5C) to 55C 100.0000 mV 0.0030 + 0.0030 0.0040 + 0.0035 0.0050 + 0.0035 0.0005 + 0.0005 1.000000 V 0.0020 + 0.0006 0.0030 + 0.0007 0.0035 + 0.0007 0.0005 + 0.0001 10.00000 V 0.0015 + 0.0004 0.0020 + 0.0005 0.0030 + 0.0005 0.0005 + 0.0001 100.0000 V 0.0020 + 0.0006 0.0035 + 0.0006 0.0040 + 0.0006 0.0005 + 0.0001 1000.000 V 4 0.0020 + 0.0006 0.0035 + 0.0006 0.0040 + 0.0006 0.0005 + 0.0001 100.0000 mV to 750.000 V 3 Hz - 5 Hz 0.50 + 0.02 0.50 + 0.03 0.50 + 0.03 0.010 + 0.003 5 Hz - 10 Hz 0.10 + 0.02 0.10 + 0.03 0.10 + 0.03 0.008 + 0.003 0.005 + 0.003 10 Hz - 20 kHz 0.02 + 0.02 0.05 + 0.03 0.06 + 0.03 20 kHz - 50 kHz 0.05 + 0.04 0.09 + 0.05 0.10 + 0.05 0.010 + 0.005 50 kHz - 100 kHz 0.20 + 0.08 0.30 + 0.08 0.40 + 0.08 0.020 + 0.008 100 kHz - 300 kHz 1.00 + 0.50 1.20 + 0.50 1.20 + 0.50 0.120 + 0.020 100.0000 1 mA 0.0030 + 0.0030 0.008 + 0.004 0.010 + 0.004 0.0006 + 0.0005 1.000000 k 1 mA 0.0020 + 0.0005 0.007 + 0.001 0.010 + 0.001 0.0006 + 0.0001 10.00000 k 100 nA||10 M 0.0020 + 0.0005 0.007 + 0.001 0.010 + 0.001 0.0006 + 0.0001 100.0000 k 10 A 0.0020 + 0.0005 0.007 + 0.001 0.010 + 0.001 0.0006 + 0.0001 1.000000 M 5 A 0.0020 + 0.0010 0.010 + 0.001 0.012 + 0.001 0.0010 + 0.0002 10.00000 M 500 A 0.0100 + 0.0010 0.030 + 0.001 0.040 + 0.001 0.0030 + 0.0004 100.0000 M 500 nA 0.200 + 0.001 0.600 + 0.001 0.800 + 0.001 0.1000 + 0.0001 1.000000 G 500 nA||10 M 2.000 + 0.001 6.000 + 0.001 8.000 + 0.001 1.0000 + 0.0001 100.0000 A < 0.03 V 0.010 + 0.020 0.040 + 0.025 0.050 + 0.025 0.0020 + 0.0030 1.000000 mA < 0.30 V 0.007 + 0.006 0.030 + 0.006 0.050 + 0.006 0.0020 + 0.0005 10.00000 mA < 0.03 V 0.007 + 0.020 0.030 + 0.020 0.050 + 0.020 0.0020 + 0.0020 100.0000 mA < 0.30 V 0.010 + 0.004 0.030 + 0.005 0.050 + 0.005 0.0020 + 0.0005 1.000000 A < 0.80 V 0.050 + 0.006 0.080 + 0.010 0.100 + 0.010 0.0050 + 0.0010 3.000000 A < 2.0 V 0.100 + 0.020 0.120 + 0.020 0.150 + 0.020 0.0050 + 0.0020 100.0000 A to 3.000000 A 3 Hz - 5 kHz 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.015 + 0.006 5 kHz - 10 kHz 0.20 + 0.04 0.20 + 0.04 0.20 + 0.04 0.030 + 0.006 100 mV 3 Hz - 5 Hz 0.070 + 0.000 0.070 + 0.000 0.070 + 0.000 0.005 + 0.000 to 750 V 5 Hz - 10 Hz 0.040 + 0.000 0.040 + 0.000 0.040 + 0.000 0.005 + 0.000 10 Hz - 40 Hz 0.020 + 0.000 0.020 + 0.000 0.020 + 0.000 0.001 + 0.000 40 Hz - 300 kHz 0.005 + 0.000 0.006 + 0.000 0.007 + 0.000 0.001 + 0.000 1.0000 nF 500 0.50 + 0.50 0.50 + 0.50 0.50 + 0.50 0.05 + 0.50 10.000 nF 1 nA 0.40 + 0.10 0.40 + 0.10 0.40 + 0.10 0.05 + 0.10 100.00 nF 10 A 0.40 + 0.10 0.40 + 0.10 0.40 + 0.10 0.01 + 0.10 1.0000 F 10 A 0.40 + 0.10 0.40 + 0.10 0.40 + 0.10 0.01 + 0.10 10.000 F 100 A 0.40 + 0.10 0.40 + 0.10 0.40 + 0.10 0.01 + 0.10 More detailed specifications atwww.agilent.com/find/34410A 181 Digital Multimeters 61/2 - Digit Multimeters 34410A-34411A (Continued) Range3 Specifications (% of reading + % of range) Frequency, Test Current or Burden Voltage 24 Hour 2 Tcal 1C 90 Day Tcal 1C 1 Year Tcal 5C Temp.Coef. 0C to (Tcal - 5C) (Tcal + 5C) to 55C Temperature9 RTD Thermistor -200C to 600C 0.06C 0.06C 0.06C 0.003C -80C to 150C 0.08C 0.08C 0.08C 0.002C Continuity 1000.0 1 mA 0.002 + 0.010 0.008 + 0.020 0.010 + 0.020 0.0010 + 0.0020 Diode Test 10 1.0000 V 1 mA 0.002 + 0.010 0.008 + 0.020 0.010 + 0.020 0.0010 + 0.0020 1 Specifications are for 1-hour warm-up and 100 PLC. 2 Relative to calibration standards. 3 20% overrange on all ranges, except DCV 1000 V, ranges, ACV 750 V, DCI and ACI 3 A ranges. 4 For each additional volt over 500 add 0.02 mV of error. 5 Specifications are for sinewave input > 0.3% of range and > 1 m Vrms. Add 30 uV error for frequencies below 1 kHz. 750 VAC range limited to 8 x 107 Volts-Hz. For each additional volt over 300 Vrms add 0.7 mVrms of error. 6 Specifications are for 4-wire resistance measurements, or 2-wire using Math Null. Without Math Null, add 0.2 ohms additional error in 2-wire resistance measurements. 7 Specifications are for sinewave input >1% of range and >10 Arms. Frequencies > 5 kHz are typical for 1.0 A and 3.0 A ranges. 8 Specifications are for 1-hour warm-up using Math Null. Additional errors may occur for non-film capacitors. 9 For total measurement accuracy, add temperature probe error. 10 Accuracy specifications are for the voltage measured at the input terminals only. 1 mA test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction. A-to D Converter Noise Performance Integration Time (NPLC) Resolution (ppm of range)1 Normal Mode Rejection (dB)12 Readings/ Second4 0.0015 30 0 50,000 5 0.002 15 0 25,000 0.006 6 0 10,000 0.02 3 0 3,000 0.06 1.5 0 1,000 0.2 0.7 0 300 1 0.3 55 60 (50) 2 0.2 110 3 30 (25) 10 0.1 110 3 6 (5) 100 0.03 110 3 0.6 (0.5) 1 Resolution is defined as the typical DCV 10 V range RMS noise. Auto-zero on for NPLC 1. See manual for additional noise characteristics. 2 Normal mode rejection for power line frequency 0.1%. 3 For power-line frequency 1% 75 dB and for 3% 55 dB. 4 Maximum rate with auto-zero off for 60 Hz and (50 Hz) operation. 5 Only available for the 34411A. More detailed specifications atwww.agilent.com/find/34410A 182 Digital Multimeters 61/2 - Digit Multimeters 34410A-34411A (Continued) DMM memory to PC (Maximum reading rate out of memory)1 Drawing, - Path B Reading Format GPIB Readings/sec USB 2.0 Readings/sec LAN (VXI-11) Readings/sec LAN (Sockets) Readings/sec ASCII 2,850 2,000 4,800 4,000 32-bit Binary 89,000 265,000 110,000 270,000 64-bit Binary 47,000 154,000 60,000 160,000 Direct I/O Measurements single reading - measure and IO time1 Drawing - Path C Function Resolution (NPLC) GPIB msec USB 2.0 msec Maximum Reading Rate into Memory or to Direct I/O LAN (VXI-11) LAN (Sockets) (Readings/secs) Drawing - msec msec Path A or C DCV/2-wire Resistance 0.006 (0.001) 34.0 34.6 5.0 34.5 10,000 (50,000) ACV/ Frequency Fast Filter 1 ms Gate 10.0 10.0 10.0 10.0 500 1 1/2 scale input signal, immediate trigger, trigger delay 0, auto-zero off, auto-range off, no math, null off, 60 Hz line frequency, null off.Specifications are for 34410A or (34411A). See manual for performance on other functions. System Performance Function Change Range Change (msec)1 (msec) 2 Auto-range (msec)3 Max. External Trigger Rate Max. Internal Trigger Rate4 DCV/ 2-wire Resistance 22 5.5 7.5 5,000/s 10,000/s (50,000/s) ACV/Frequency 37 6.5 19 500/s 500/s 1 Time to change from 2-wire Resistance to this specified function, or dcv DCV to 2-wire Resistance using the SCPI " (FUNC " '----" command) 2 Time to change from one range to the next higher range, 10 V, 10 M 3 Time to automatically change one range and be ready for the new measurement, 10 V, 10 M, 10 V, 10 Mohm 4 Specifications are for 34410A or (34411A). More detailed specifications atwww.agilent.com/find/34410A 183 Digital Multimeters Nanovolt/Micro-ohm Meter 34420A 34420A 34420A Nanovolt/Micro-ohm Meter The Agilent 34420A sets a price/ performance standard in low-level measurement capability. The noise performance of the 34420A nanovolt/micro-ohm meter is more than an order of magnitude better than that previously available from Hewlett-Packard. Accurate, Repeatable Low-Level Measurements A shielded copper pin screw-down connector, a 71/2 digit A/D, converter 2 ppm basic DC accuracy, and a new measurement algorithm that gives 100 dB normal mode rejection without front-end filtering result in measurement capability you can depend on to make accurate and repeatable low-level measurements. Low noise input amplifiers and a highly-tuned input protection scheme bring reading noise down to 8 nVp-p. Longer integration times improve noise performance even further. Math Functions Enhance Capabilities Math functions such as NULL, STATS, and SCALE ease the capture of minimum and maximum readings, provide averages and standard 71/2 digit resolution 1 mV to 100 V ranges 1.3 nV rms noise/8 nVp-p SCPI and Keithley 181 languages 100 pV, 100 n sensitivity Direct SPRT, RTD, Thermistor, and thermocouple temperature measurements Two-channel programmable voltage input; difference and ratio functions deviation, scale your measurement results, and ultimately makes it easier for you to characterize your input signal. The 34420A can also store up to 1024 readings in internal memory. Agilent IntuiLink: Easy Data Access The Included Agilent IntuiLink software allows your captured data to be put to work easily, using PC applications such as Microsoft Excel or Microsoft Word, to analyze, interpret, display, print, and document the data you get from the 34420A. To find out more about IntuiLink, visit www.agilent.com/find/intuilink Unprecedented Functionality Two input channels allow voltage measurements to be made independently, or they can be mathematically combined to make difference and ratio measurements. Ohms measurements combine the low-noise input circuits with a highly-stable current source to provide outstanding low-resistance measurements. Offset compensation is employed to eliminate the effects of stray thermal EMFs that would otherwise result in measurement IntuiLink Connectivity Software included error. Low power ohms and a low-voltage resistance measurement capability allow repeatable measurements to be made where a low voltage (20 mV) is required to avoid oxidation punch-through. A wide range of temperature measurement capabilities are also built in, providing support for SPRT, thermocouple, RTD, and thermistor temperature sensors. Built-in Versatility You will find that the 34420A will fit equally well into your bench or your system applications. Designed with the bench user in mind, operation of the 34420A from the front panel is straightforward and intuitive. For system applications, the 34420A includes both GPIB and RS-232 interfaces standard, and uses Standard Commands for Programmable Instrumentation (SCPI). This ensures both present and future compatibility. The 34420A also responds to commands for the Keithley 181 nanovoltmeter. More detailed specifications at www.agilent.com/find/34420A 184 Digital Multimeters Nanovolt/Micro-ohm Meter 34420A (Continued) Abbreviated Technical Specifications DC Voltage 1 - 7 1/2 digits Resolution all Ranges Accuracy Specifications: (% of reading + % of range) Range 24-Hour 23C 1C 90-Day 23C 5C 1-Year 23C 5C 1 mV 0.0025 + 0.0020 0.0040 + 0.0020 0.0050 + 0.0020 10 mV 0.0025 + 0.0002 0.0040 + 0.0002 0.0050 + 0.0003 100 mV 0.0015 + 0.0003 0.0030 + 0.0004 0.0040 + 0.0004 SPRT: ITS-90 calibrated temperature within the range of -190 to +660C 1V 0.0010 + 0.0003 0.0025 + 0.0004 0.0035 + 0.0004 10 V 0.0002 + 0.0001 0.0020 + 0.0004 0.0030 + 0.0004 RTD: Type A = 0.00385 and A = 0.00392. R0 from 4.9 to 2.1 K. ITS-90 (IEC 751) Callendar-Van Dusen conversion 100 V 0.0010 + 0.0004 0.0025 + 0.0005 0.0035 + 0.0005 Temperature Thermistor: 5 K DCV1/DCV2 (ratio): Ratio error in % = channel 1 accuracy in % + channel 2 accuracy in % DCV1-2 (difference): Differnce error = channel 1 (% reading + % range) + channel 2 (% reading + % range) Thermocouple: ITS-90 conversions of type B, E, J, K, N, R, S, T DC Voltage Noise Specifications 2 Chart Out (Analog Out) Range 2-Minute rms Noise 2 - Minute p-p Noise 24-Hour p-p Noise 1 mV 1.3 nV RMS 8 nV p-p 12 nV p-p 10 mV 1.5 nV RMS 10 nV p-p 14 nV p-p 100 mV 10 nV RMS 65 nV p-p 80 nV p-p 1V 100 nV RMS 650 nV p-p 800 nV p-p 10 V 450 nV RMS 3 V p-p 3.7 V p-p 100 V 11 V RMS 75 V p-p 90 V p-p DC Voltage: Input Resistance: 10 M 1% (100 V range) >10 G (1 mV through 10 V range) Input Protection: 150 V peak to Channel 1 LO Resolution: 16 bits Maximum Output: 3 V Span and Offset: Adjustable Filter (Analog or Digital or Both) Analog: Low pass 2 pole @13 Hz, available for dcV on 1 mV, 10 mV, 100 mV ranges Digital: Moving average filter. 10 (fast), 50 (medium) or 100 (slow) reading averages Math Functions NULL (Channel 1 dcV, Channel 2 dcV, Difference, Resistance, Temperature) STATS (Min/max/avg, peak-peak, standard deviation, number of readings) SCALE (Allows linear scaling as Y=MX + B) CHART NULL (Establishes zero for rear-panel output) Application Information Digital Multimeter Measurement Errors Series System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters Application Note AN 1389-1 5988-5511EN Digital Multimeter Measurement Errors Series Resistance; DC Current; AC Current; and Frequency and Period Measurement Errors in Digital Multimeters. Application Note AN 1389-2 5988-5512EN Resistance 3 - 7 1/2 digits Resolution all Ranges Range Test Current 24-Hour 23C 1C 90-Day 23C 5C 1-Year 23C 5C 1 10 mA 0.0015 + 0.0002 0.0050 + 0.0002 0.0070 + 0.0002 10 10 mA 0.0015 + 0.0002 0.0040 + 0.0002 0.0060 + 0.0002 100 10 mA 0.0015 + 0.0002 0.0040 + 0.0002 0.0060 + 0.0002 1 k 1 mA 0.0015 + 0.0002 0.0040 + 0.0002 0.0060 + 0.0002 10 k 100 A 0.0015 + 0.0002 0.0040 + 0.0002 0.0060 + 0.0002 100 k 10 A 0.0015 + 0.0003 0.0040 + 0.0004 0.0060 + 0.0004 1 M 5 A 0.0015 + 0.0003 0.0050 + 0.0004 0.0070 + 0.0004 1 Specifications are for channel 1 or channel 2 (100 V range on channel 1 only), after 2-hour warm-up, resolution at 7.5 digits (100 NPLC), with filters off. 2 After a 2-hour warm-up 1C, 6.5 digits (10 NPLC) with analog filter off digital filter medium (50 readings). 2 minute rms and 24-hour noise typical. 3 All resistance specifications are for channel 1 only, after 2-hour warm-up, resolution at 7.5 digits (100 NPLC) with filters off, for 4-wire or 2-wire using Null. 4 For 25 SPRT with triple-point of water check within last 4 hours. With no triple-point of water check, add 0.013C for 24-hour, 0.035C for 90-day, and 0.055C for 1-year specifications. 5 For fixed reference junction. Add 0.3C for external reference junction, add 2.0C for internal reference junction. More detailed specifications at www.agilent.com/find/34420A 185 Digital Multimeters Nanovolt/Micro-ohm Meter 34420A (Continued) Abbreviated Technical Specifications Low Power Resistance3 - 71/2 digits Resolution all Ranges Accuracy Specifications: (% of reading + % of range) Range Test Current 24-Hour 23C 1C 90-Day 23C 5C 1-Year 23C 5C 1 10 mA 0.0015 + 0.0002 0.0050 + 0.0002 0.0070 + 0.0002 10 10 mA 0.0015 + 0.0002 0.0040 + 0.0002 0.0060 + 0.0002 General Specifications 100 1 mA 0.0015 + 0.0002 0.0040 + 0.0002 0.0060 + 0.0002 Front-Panel Connection: Shielded, low-thermal, copper contacts 1 k 100 A 0.0015 + 0.0002 0.0040 + 0.0002 0.0060 + 0.0002 10 k 10 A 0.0015 + 0.0004 0.0040 + 0.0004 0.0060 + 0.0004 100 k 5 A 0.0015 + 0.0012 0.0040 + 0.0015 0.0060 + 0.0015 1 M 5 A 0.0020 + 0.0003 0.0050 + 0.0004 0.0070 + 0.0004 Interface: GPIB and RS-232 standard Languages: SCPI-1994 (IEEE-488.2), Keithley 181 Ordering Information 34420A Nanovolt/Micro-Ohm Meter Includes low-thermal input cable (34102A), low-thermal shorting plug (34103A), operating and service manuals, quick reference guide, test report with calibration sticker, 2.3 ml bottle of contact cleaner, and power cord. 34420A-1CM Rackmount Kit Voltage Limited Resistance 3: Voltage limit selectable: 20 mV, 100 mV, or 500 mV Range Test Current 24-Hour 23C 1C 90-Day 23C 5C 1-Year 23C 5C 10 1 mA 0.0020 + 0.0002 0.0050 + 0.0002 0.0070 + 0.0002 100 100 A 0.0025 + 0.0002 0.0040 + 0.0002 0.0070 + 0.0002 34420A-A6J ANSI Z540 Compliant Calibration Accessories Temperature: 0.001C Resolution 34102A Low-Thermal Input Cable (fourconductor with copper spade lugs) Probe Type Accuracy SPRT4 SPRT probe accuracy +0.003C 34161A Accessory Pouch RTD RTD probe accuracy +0.05C 34131A Hard Transit Case Thermistor Thermistor probe accuracy +0.1C Thermocouple5 Thermocouple probe accuracy +0.2C 34103A Low-Thermal Shorting Plug 34104A Low-Thermal Input Connector 1 2 3 4 5 Specifications are for channel 1 or channel 2 (100 V range on channel 1 only), after 2-hour warm-up, resolution at 7.5 digits (100 NPLC), with filters off. After a 2-hour warm-up 1C, 6.5 digits (10 NPLC) with analog filter off digital filter medium (50 readings). 2 minute rms and 24-hour noise typical. All resistance specifications are for channel 1 only, after 2-hour warm-up, resolution at 7.5 digits (100 NPLC) with filters off, for 4-wire or 2-wire using Null. For 25 SPRT with triple-point of water check within last 4 hours. With no triple-point of water check, add 0.013C for 24-hour, 0.035C for 90-day, and 0.055C for 1-year specifications. For fixed reference junction. Add 0.3C for external reference junction, add 2.0C for internal reference junction. More detailed specifications at www.agilent.com/find/34420A 186 Digital Multimeters 81/2 -Digit Multimeter 3458A 81/2 digit resolution 100,000 reading/s (41/2 digits) 8 ppm (4 ppm optional) voltage stability - 1 year 3458A To 1000 V input range Abbreviated Technical Specifications 3458A Multimeter The Agilent 3458A multimeter shatters long-standing performance barriers of speed and accuracy on the production test floor, in research and development, and in the calibration lab. The 3458A is the fastest, most flexible, and most accurate multimeter offered by Agilent Technologies. In your system or on the bench, the 3458A saves you time and money with unprecedented test-system throughput and accuracy, seven-function measurement flexibility, and low cost of ownership. Select a rate of 100,000 reading per second for maximal test throughput. Or achieve highest levels of precision with up to 81.2 digits of measurement resolution and 0.1 part per million transfer accuracy. Add to this the 3458A's simplicity of operation, and you have the ideal multimeter for your most demanding applications. High-Test System Throughput Faster Testing * Up to 100,000 readings/s * Internal test setups >340/s * Programmable integration times from 500 ns to 1 s Extraordinary Accuracy Greater Test Yield * More accuracy for tighter test margins * Up to 81/2 digits resolution Longer Uptime * Two-source (10 V, 10 k) calibration, including AC * Self-adjusting, self-verifying auto-calibration for all functions and ranges, including AC High-Resolution Digitizing Greater Waveform Resolution and Accuracy * * * * * * 16 to 24-bits resolution 100,000 to 0.2 sample/s 12 MHz bandwidth Timing resolution to 10 ns Less than 100 ps time jitter Over 75,000 reading internal memory Calibration Lab Precision Superb Transfer Measurements * 81/2 digits resolution * 0.1 ppm DC volts linearity * 0.1 ppm DC volts transfer capability * 0.01 ppm rms internal noise * * * * 0.6 ppm for 24 hours in DC volts 2.2 ppm for 24 hours in 100 ppm mid-band AC volts 8 ppm (4 ppm optional) per year voltage reference stability 3458A Multimeter Performance Features DC Volts * 5 ranges: 0.1 V to 1000 V * 81/2 to 41/2 digits resolution * Up to 100,000 readings/s (41/2 digits) * Maximum sensitivity: 10 nV * 0.6 ppm 24-hour accuracy * 8 ppm (4 ppm optional)/year voltage reference stability Resistance * 9 ranges: 10 to 1 G * 2-wire and 4-wire with offset compensation * Up to 50,000 readings/second (51/2 digits) * Maximum sensitivity: 10 * 2.2 ppm 24-hour accuracy AC Volts * 6 ranges: 10 mV to 1000 V * 1 Hz to 10 MHz bandwidth * Up to 50 readings/s with all readings to specified accuracy * Choice of sampling or analog true rms techniques * 100 ppm best accuracy More detailed specifications at www.agilent.com/find/multimeters 187 Digital Multimeters 81/2 -Digit Multimeter 3458A (Continued) Abbreviated Technical Specifications DC Voltage Range Full Scale Maximum Resolution 1-Year* Transfer Accuracy Input 10 min., tref 0.5C Impedence Accuracy ppm of reading + ppm of range 100 mV 120.00000 10 nV 9(5) + 3 0.5 + 0.5 >10 G 1V 1.20000000 10 nV 8(4) + 0.3 0.3 + 0.1 >10 G DC Current 10 V 12.0000000 100 nV 8(4) + 0.05 0.05 + 0.05 >10 G * * * * 100 V 120.000000 1 V 10(6) + 0.3 0.5 + 0.1 10 M 1% 1000 V 1050.00000 10 V 10(6) + 0.1 1.5 + 0.05 10 M 1% 8 ranges: 100 nA to 1 A Up to 1,350 readings/s (51/2 digits) Maximum sensitivity: 1 pA 14 ppm 24-hour accuracy AC Current * * * * 5 ranges: 100 A to 1 A 10 Hz to 100 kHz bandwidth Up to 50 readings/second 500 ppm 24-hour accuracy Frequency and Period * * * * * Voltage or current ranges Frequency: 1 Hz to 10 MHz Period: 100 ns to 1 second 0.01% accuracy AC or DC coupled One-year specifications for NPLC 100 within 24 hours and 1C of last ACAL, Tcal 5C, MATH NULL, fixed range. Add 2 ppm of reading additional error for Agilent factory traceability of 10 V DC to US NIST. Traceability error is the absolute error relative to National Standards associated with the source of last external calibration. Transfer specifications for NPLC 100, following 4-hour warm-up. Full scale to 10% of full scale. Measurements on the 1000 V range are within 5% of the initial measurement value and following measurement settling. Tref is the starting ambient temperature. Measurements are made on a fixed range using accepted metrology practices. *High stability (Option 002) ppm of reading in parentheses. Noise Rejection (dB) 1 AC NMR 2 AC ECMR DC ECMR NPLC <1 0 90 140 NPLC 1 60 150 140 NPLC 10 60 150 140 NPLC 100 60 160 140 Throughput NPLC = 1000 75 170 140 Maximum Reading Rates 1 Applies for 1 k unbalance in the LO lead and 0.1% of the line frequency currently set for LFREQ. 2 For line frequency 1%, ACNMR is 40 dB for NPLC 1, or 55 dB for NPLC 100. * 100,000 readings/s at 41/2 digits (16 bits) * 50,000 readings/s at 51/2 digits * 6,000 readings/s at 61/2 digits * 60 readings/s at 71/2 digits * 6 readings/s at 81/2 digits For line frequency 5%, ACNMR is 30 dB for NPLC 100. DC Maximum Input Rated Input Nondestructive Measurement System Speed * 100,000 readings/s over GPIB or with internal memory * 110 autoranges/s * 340 function or range changes/s * Postprocessed math from internal memory HI to LO 1000 V pk 1200 V pk LO to guard 200 V pk 300 V pk Guard to earth 500 V pk 1000 V pk Math Functions The 3458A performs the following math functions on measurements: null, scale, offset, rms filter, single pole filter, thermistor linearization, db, dbm, % error, pass/fail LIMIT TESTING, and statistics. Two math functions may be used at one time. More detailed specifications at www.agilent.com/find/multimeters 188 Digital Multimeters 81/2 -Digit Multimeter 3458A (Continued) Abbreviated Technical Specifications (Continued) True rms AC Voltage (Synchronous Subsampled Mode) Range Full Scale Maximum Resolution Accuracy* 24 Hour - 2 Year 40 Hz to 1 kHz % of reading + % of range Input Impedance 10 mV 12.00000 10 nV 0.02 + 0.011 1 M 15% with <140 pf Application Information: 100 mV 120.00000 10 nV 0.007 + 0.002 1 M 15% with <140 pf Notes Digital Multimeter Measurement Errors Series System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters Application Note AN 1389-1 5988-5511EN 1V 1.2000000 100 nV 0.007 + 0.002 1 M 15% with <140 pf 10 V 12.000000 1 V 0.007 + 0.002 1 M 2% with <140 pf 100 V 120.00000 10 V 0.02 + 0.002 1 M 2% with <140 pf 1000 V 700.0000 100 V 0.04 + 0.002 1 M 2% with <140 pf Digital Multimeter Measurement Errors Series Resistance; DC Current; AC Current; and Frequency and Period Measurement Errors in Digital Multimeters. Application Note AN 1389-2 5988-5512EN Digital Multimeter Measurement Errors Series AC Voltage Measurement Errors in Digital Multimeters Application Note AN 1389-3 5988-5513EN * Specifications apply for full scale to 10% of full scale, DC <10% of AC, sine-wave input, crest factor of 1.4. Within 24 hours and 1C of last ACAL. Peak (AC+DC) input limited to 5 x full scale for all ranges. Add 2 ppm of reading additional error for Agilent factory traceability of 10 Vdc to US NIST. AC Maximum Input Rated Input HI to LO LO to guard 1000 V pk 200 V pk Nondestructive 1200 V pk 350 V pk Guard to earth 500 V pk 1000 V pk Volt-Hz product 1 x 10* - General Specifications Operating Temperature: 0C to 55C Warmup Time: Four hours to all specifications except where noted Resistance Range Full Scale Maximum Resolution Current Source 1-Year Accuracy* (4-wire ) ppm of rdg+ppm of range 10 12.00000 10 10 mA 15 + 5 Power: 100/120 V, 220/240 V 10%, 48 to 66 Hz, 360 to 420 Hz automatically sensed. Fused at 1.5 A @115 V or 0.5 A @230 V. <30 W, < 80 VA (peak). 100 120.00000 10 1 mA 12 + 5 1 k 1.2000000 100 1 mA 10 + 0.5 10 k 12.000000 1 m 100 A 10 + 0.5 Size: 88.9 mm H x 425.5 mm W x 502.9 mm D (3.5 in x 16.75 in x 19.8 in) 100 k 120.00000 10 m 50 A 10 + 0.5 1 M 1.2000000 100 m 5 A 15 + 2 Weight: Net, 12 kg (26.5 lb); shipping, 14.8 kg (32.5 lb) 10 M 12.000000 1 500 nA 50 + 10 100 M 120.00000 10 500 nA 500 + 10 1 G 1.2000000 100 500 nA 0.5% + 10 Standard Readings Bytes Option 001 Readings Bytes Reading Storage (16 bit) 10,240 20 k +65,536 +128 k Non-volatile, for Subprograms and/or State Storage - 14 k - - Humidity Range: 95% RH, 0C to 40C Storage Temperature: -40C to +75C Ordering Information 3458A Multimeter (with GPIB, 20 KB reading memory, and 8 ppm stability) 3458A-001 Extended Reading Memory (expands total to 148 KB) 3458A-002 High-Stability (4 ppm/year) Reference 3458A-A6J ANSI Z540 Compliant Calibration 3458A-907 Front-handle Kit 3458A-908 Rack Flange Kit 3458A-909 Rack Flange Kit (with handles) Memory More detailed specifications at www.agilent.com/find/multimeters 189 Frequency Counters Selection Guide Model Frequency range (optional range) Frequency resolution Best Sensitivity Time Interval resolution (single-shot LSD) Additional features Two channel frequency counters w/time interval1 53131A 225 MHz (3, 5, 12.4 GHz) 10 digits/s 20 mVrms 500 ps GPIB standard, full math, statistics, limit testing, auto pulse characterization 53132A 225 MHz (3, 5, 12.4 GHz) 12 digits/s 20 mVrms 150 ps GPIB standard, full math, statistics, limit testing, auto pulse characterization Single channel frequency counter 53181A 225 MHz 10 digits/s (1.5, 3, 5, 12.4 GHz) 20 mVrms GPIB standard, full math, statistics, limit testing CW Microwave counters 53150A 20 GHz 1 Hz -30 dBm GPIB standard, battery optional, Simultaneous power measurement 53151A 26.5 GHz 1 Hz -30 dBm GPIB standard, battery optional, Simultaneous power measurement 53152A 46 GHz 1 Hz -30 dBm GPIB standard, battery optional, Simultaneous power measurement 53147A 20 GHz 1 Hz -30 dBm GPIB and DVM standard, battery optional,-70 dBm to +20 dBm true power meter 53148A 26.5 GHz 1 Hz -30 dBm GPIB standard, battery optional, -70 dBm to +20 dBm true power meter 53149A 46 GHz 1 Hz -30 dBm GPIB standard, battery optional, -70 dBm to +20 dBm true power meter CW Microwave counters/ power meter/DVMs 1 Channel 2 can be used to make frequency, period, ratio, and voltage measurements - measurements on channel 1 and channel 2 are made sequentially. Additional frequency counters Agilent also offers frequency counters for VXI and the popular 34980A and 34970A data acquisition mainframes. More information is available for these counters on the Agilent website. Connectivity Agilent provides IntuiLink a free software application for your PC. IntuiLink allows you to easily transfer measurement data and images into familiar PC applications like Microsoft Office Excel and Word. IntuiLink can be downloaded free of charge at www.agilent.com/find/intuilink IntuiLink supports the 53131A, 53132A and the 53181A. Agilent offers the 82357A USB to GPIB converter making it easy to connect your counter to a PC using USB. More detailed specifications at www.agilent.com/find/frequencycounters 190 Frequency Counters 53131A 53132A Frequency Counters 53131A, 53132A, and 53181A 225 MHz bandwidth (optional 1.5, 3, 5, or 12.4 GHz) 10- or 12-digit/s resolution GPIB interface and IntuiLink connectivity software standard Data transfer rate of up to 200 fully formatted measurements / second 53181A 53131A 53132A 53181A Type Two channel, universal1 Two channel, universal1 One channel RF Measurements Frequency, frequency ratio, time interval, period, rise/fall time, positive/negative pulse width, duty cycle, phase, totalize, peak voltage, time interval average, time interval delay Analysis Automatic limit testing, math (scale and offset), statistics (minimum, maximum, mean, standard deviation) Frequency range (optional channel) DC to 225 MHz (3, 5 or 12.4 GHz) DC to 225 MHz (3, 5 or 12.4 GHz) DC to 225 MHz (1.5, 3, 5 or 12.4 GHz) Resolution (frequency, time interval) 10 digits/s, 500 ps 12 digits/s, 150 ps 10 digits/s, N/A Measurement speed Up to 200 meas/s over GPIB Up to 200 meas/s over GPIB Up to 200 meas/s over GPIB Voltage range & sensitivity (Sinusoid) DC to 100 MHz 100 to 200 MHz 200 to 225 MHz With Optional Channel 20 mVrms to 5 Vac +DC 30 mVrms to 5 Vac +DC 40 mVrms to 5 Vac +DC 75 mVrms to 5 Vac +DC 20 mVrms to 5 Vac +DC 30 mVrms to 5 Vac +DC 40 mVrms to 5 Vac +DC 75 mVrms to 5 Vac +DC 20 mVrms to 5 Vac +DC 30 mVrms to 5 Vac +DC 40 mVrms to 5 Vac +DC 75 mVrms to 5 Vac +DC (Independently selectable on CH 1 & 2) 1 M or 50 , AC or DC 100 kHz or none x1 or x10 (Independently selectable on CH 1 & 2) 1 M or 50 , AC or DC 100 kHz or none x1 or x10 (Independently selectable on CH 1) 1 M or 50 , AC or DC 100 kHz or none x1 or x10 External timebase reference Input 1, 5, 10 MHz 10 MHz 1, 5, 10 MHz Trigger CH 1 & CH 2 CH 1 & CH 2 CH 1 Abbreviated technical specifications A family of frequency counters to meet your needs Agilent Technologies 53131A, 53132A and 53181A frequency counters give you fast, precise frequency measurements at an affordable price. These counters feature an intuitive user interface and one-button access to frequently used functions so you can make accurate measurements quickly and easily. Real-time digital signal processing technology is used to analyze data while simultaneously taking new readings, speeding measurement throughput. This series of counters offers builtin statistics and math functions so you can scale measurements and simultaneously measure and track average, min/max and standard deviation. Automated limit testing lets you set upper and lower limits for any measurement. The analog display mode lets you see at a glance whether a measurement is within pass/fail limits. The counters flag out-of-limit conditions and can generate an output signal to trigger external devices when a limit is exceeded. For quick access to frequently used tests, a single keystroke recalls up to 20 different stored front-panel set-ups. Input Conditioning Impedance coupling Low pass filter Attenuation Frequency, frequency ratio (with optional second channel 2), period, peak voltage Trigger on rising/falling edge; set level as a percent of signal level or voltage; Sensitivity can be set as LOW, MED, HIGH Gating and arming Auto, manual (set gate time or number of digits of resolution); external, delay (expanded on 53132A) Interfaces GPIB (IEEE 488.1 and 488.2) with SCPI-compatible language; talk only RS-232 Power AC line selection is automatic 100 to 120 VAC 10% at 50, 60, or 400 Hz 10% 220 to 240 VAC 10% at 50, 60 Hz 10% Net weight/size 3 kg (6.5 lbs.) 88.5mm H x 212.6mm W x 348.3mm D (3.54 in x 8.50 in x 13.932 in) 1 Channel 2 can only be used to make frequency, period, ratio, and voltage measurements - measurements on channel 1 and channel 2 are made sequentially. More detailed specifications at www.agilent.com/find/frequencycounters 191 Frequency Counters Frequency Counters 53131A, 53132A, and 53181A (Continued) Standard and optional high stability timebases Temperature stability (referenced to 25 C) Agilent 53131A Universal Counter The two-channel 53131A counter offers a bandwidth of 225 MHz with a resolution of 10 digits per second when measuring frequency or period. Time interval measurements may also be made with a resolution of 500 ps. An optional third channel can be added to any counter to provide frequency measurements up to 3 GHz, 5 GHz, or 12.4 GHz. Agilent 53132A Universal Counter For applications requiring higher resolution, the 53132A offers the same features and functions as the 53131A, with up to 12 digits per second frequency resolution and 150 ps time interval resolution. If more accuracy is required, a choice of optional timebases may be added to any of the counters. In addition, the 53132A offers advanced arming modes for time interval measurements. Agilent 53181A RF Counter Optimized for RF applications, the single-channel 10 digits per second. 53181A measures frequency, period and peak voltage. A digit-blanking function easily eliminates unnecessary digits when you want to read measurements quickly. For higher frequency measurements, choose an optional second channel. A selfguided menu makes this counter exceptionally easy to use. Connectivity For computer-controlled systems applications, each counter includes a standard GPIB interface with full SCPI-compatible programmability and a data transfer rate of up to 200 fully formatted measurements Aging Rate (after 30 days) Per Day: Per Month: Per Year: Standard Medium Oven High Oven Ultra High Oven (0 to 50C) Option 001 Option 010 Option 012 < 5 x 10-6 < 2 x 10-7 < 2.5 x 10-9 < 2.5 x 10-9 < 3 x 10-7 < 4 x 10-8 < 2 x 10-7 < 5 x 10-10 < 1.5 x 10-8 < 1 x 10-10 < 3 x 10-9 < 2 x 10-8 < 2 x 10-7 (Referenced to 2 hours) < 5 x 10-9 (Referenced to 24 hours) < 5 x 10-9 (Referenced to 24 hours) Electronic Electronic Electronic Turn-on stability vs. time (30 minutes) Calibration Manual Adjust Note: that power to the time base is maintained when the counter is placed in standby via the front panel switch. The internal fan will continue to operate when in standby to maintain long-term measurement reliability. Optional High Frequency Channels Frequency range Connector Coupling Power range and sensitivity Damage level Option 0151 1.5 GHz Channel 100 MHz to 1.5 GHz BNC AC -27 dBm to +19 dBm 5 Vrms Optional 030 3.0 GHz Channel 100 MHz to 3.0 GHz BNC AC -27 dBm to +19 dBm (100 MHz to 2.7 GHz) 5 Vrms -21 dBm to +13 dBm (2.7 GHz to 3 GHz) Optional 050 5.0 GHz Channel 200 MHz to 5.0 GHz Type-N AC -23 dBm to +13 dBm 25 dBm Optional 124 12.4 GHz Channel 200 MHz to 12.4 GHz Type-N AC -23 dBm to +13 dBm 25 dBm 1 Option 015 is available only for the 53181A per second. Measurements can be transferred via USB with an optional 82357A GPIB to USB converter. The standard RS-232 talk-only interface provides printer support or data transfer to a computer through a terminal-emulation program. IntuiLink, free PC connectivity software allows you to easily transfer measurement data and images into familiar PC applications like Microsoft Office Excel and Word, with little or no programming. Use the following link for additional and downloading instructions. www.agilent.com/find/intuilink More detailed specifications at www.agilent.com/find/frequencycounters 192 Frequency Counters Frequency Counters 53131A, 53132A, and 53181A (Continued) Drivers Ordering Information 53131A/53132A/53181A: IntuiLink Connectivity Software Agilent 53131A Universal Counter, 10 digit/s Application Notes: Agilent 53132A Universal Counter, 12 digit/s 8 Hints for Making Better RF Counter Measurements This brochure focuses on making better RF counter measurements by understanding the effects of counter architecture; recognizing the difference between resolution and accuracy, and scheduling calibration to match performance needs. 5967-6038E Find a video demo, specifications calculator and more at www.agilent.com/find/frequencycounters Agilent 53181A RF Counter, 10 digit/s Option 001 Medium stability timebase Option 010 High stability timebase Option 012 Ultra stability timebase Option 060 Adds parallel 225 MHz channel(s) to rear panel Option 061 Adds parallel 225 MHz channel(s) to rear panel and moves option 030 to rear panel. Option 062 Adds parallel 225 MHz channel(s) to rear panel, opt 050 or opt 124 remain on front panel. Option 1CM Rack mount kit 82357A Optional USB Interface Option 015 1.5 GHz Ch. w/BNC connector Option 030 3.0 GHz Ch. w/BNC connector Option 050 5.0 GHz Ch. w/Type-N connector Option 124 12.4 GHz Ch. w/Type-N connector 1 Option 015 is available only for the 53131A Configure a counter that is right for your application Start by selecting a counter, either the 53131A, 53132A, or 53181A. Don't know which one to choose? Check out our most popular 53131A. Then choose the timebase that is the best fit for your application. Optional timebases improve stability due to changes in temperature or time and provide the convenience of electronic calibration. Finally, an optional RF channel can be added to measure signals up to 12.4 GHz - opt 030, a 3 GHz RF channel is a common choice. More detailed specifications at www.agilent.com/find/frequencycounters 193 Microwave Frequency Counters Microwave Frequency Counter w/power meter, 53140 Series A choice of frequency counter ranges up to 46 GHz A true power meter to meet your "laboratory-accuracy" requirements A DC DVM to assist with antenna alignment and telecom power supply measurements 53147A - 53149A GPIB and RS232 standard Abbreviated technical data Input characteristics Simplify design and verification of point-to-point microwave links Whether you are designing or verifying cell-site to base-station links, business-to-business communication links, digital radio links (along railroads, pipelines or power lines) or even satellite ground stations, designing and verifying microwave links typically requires three pieces of equipment. These are a CW microwave counter, a true power meter and a DC DVM. Frequency range Save ATE rack space and budget dollars by combining three instruments into one For measurements used in microwave component and assembly testing, the compact, three-in-one 53140 series reduces the need for expensive ATE rack space. The 53140 series comes ATE-ready with both GPIB and RS-232 SCPI programmable interfaces. A rack mount kit is optional. CW microwave counter up to 46 GHz Choose the frequency range you need. The 53140 series has three ranges; 20 GHz, 26.5 GHz and 46 GHz. The ultra-wideband microwave input covers from 50 MHz up to the maximum frequency. This reduces the need for channel Sensitivity Maximum input Damage level Impedance (Nominal) Connector SWR (typical) Agilent 53147A Agilent 53148A Agilent 53149A Channel 1 Normal mode Low pass filter enabled 10 Hz - 125 MHz 10 Hz - 50 kHz 10 Hz - 125 MHz 10 Hz - 50 kHz 10 Hz - 125 MHz 10 Hz - 50 kHz Channel 2 50 MHz - 20 GHz 50 MHz - 26.5 GHz 50 MHz - 46.0 GHz Channel 1 10-30 Hz 30 Hz-125 MHz 40 mV 25 mV 40 mV 25 mV 40 mV 25 mV Channel 2 50-250 MHz 0.25-12.4 GHz 12.4-18 GHz 18-20 GHz 20-26.5 GHz 26.5-40 GHz 40-46 GHz -20 dBm -33 dBm -33 dBm -29 dBm N/A N/A N/A -20 dBm -33 dBm -33 dBm -29 dBm -25 dBM N/A N/A -20 dBm -33 dBm -30 dBm -27 dBm -27 dBm -23 dBm -17 dBm Channel 1 2 Vrms 2 Vrms 2 Vrms Channel 2 50 MHz - 2 GHz 2-46 GHz +5 dBm +13 dBm +5 dBm +13 dBm +5 dBm +13 dBm Channel 1 120 Vpk (DC + AC) linearly derated to 5 Vrms at 125 MHz 120 Vpk (DC + AC) linearly derated to 5 Vrms at 125 MHz 120 Vpk (DC + AC) linearly derated to 5 Vrms at 125 MHz Channel 2 +27 dBm +27 dBm +27 dBm Channel 1 1 M / 60 pF 1 M / 60 pF 1 M / 60 pF Channel 2 50 50 50 Channel 1 BNC female BNC female BNC female Channel 2 SMA/APC-3.5 compatible female SMA/APC-3.5 compatible female 2.92 mm removable, SMA/APC-3.5 compatible female 1.5:1 2.0:1 3.0:1 N/A N/A 1.5:1 2.0:1 3.0:1 3.0:1 N/A 1.5:1 2.0:1 3.0:1 2.5:1 2.5:1 Channel 2 50-250 MHz 0.25-10 GHz 10-20 GHz 20-26.5 GHz 26.5-46 GHz More detailed specifications at www.agilent.com/find/microwavecounters 194 Microwave Frequency Counters Microwave Frequency Counter w/power meter, 53140 Series (Continued) Abbreviated technical data Input characteristics Coupling switching. You don't have to wait for resolution that is not needed, as the resolution is selectable from 1 Hz to 1 MHz. For better measurement accuracy over time and temperature, an optional oven timebase is available. True power meter with a wide selection of sensors The 53140 series true power meter provides laboratory instrument. Obtain 0.01 dB resolution and 0.02 dB basic instrument accuracy. DC DVM for AGC and power supply measurements A 50 Vdc DVM monitors the microwave receiver's AGC circuitry for assistance during antenna alignment. The DVM can also check the -48 Vdc power supplies typically found at telecom sites. Advanced instrument features that help make the job easier The Agilent 53140 series has the features you expect in a precision laboratory instrument. Relative readings for both frequency and power measurements show deviations from nominal values. Offset reading allows indirect measurement of either final frequency or power values or both. Averaging smoothes out rapidly changing measurement displays for ease of viewing. Agilent 53147A Agilent 53148A Agilent 53149A Channel 1 AC AC AC Channel 2 AC AC AC Acquisition Channel 1 time Channel 2 (1 MHz FM rate) (FM Auto/ FM Off) N/A N/A N/A 150 ms/125 ms 150 ms/125 ms 165 ms/140 ms Resolution Channel 1/ Channel 2 1 Hz to 1 MHz 1 Hz to 1 MHz 1 Hz to 1 MHz Emissions ("kickback noise") Channel 1 N/A N/A N/A Channel 2 (measuring/ no input) -40 dBm / <-70 dBm -40 dBm / <-70 dBm -40 dBm / <-70 dBm Residual stability* Channel 1 N/A N/A N/A Channel 2 0.6 LSD rms 0.8 LSD rms 1.25 LSD rms Channel 1/ Channel 2 1 LSD 1 LSD 1 LSD residual stability residual stability residual stability timebase error x frequency timebase error x frequency timebase error x frequency *Counter and source tied to same timebase Accuracy Measurement time FM tolerance Channel 1 1/Resolution + 30 ms 1/Resolution + 30 ms Channel 2 1/Resolution + acquisition time + 30 ms 1/Resolution + 1/Resolution + acquisition time + 30 ms acquisition time + 30 ms Channel 1 N/A N/A N/A 20 MHz p-p max @ 10 MHz rate 20 MHz p-p max @ 10 MHz rate 1 MHz p-p @ 10 MHz rate 20 MHz p-p max to 26.5 GHz, 12 MHz p-p max above 26.5 GHz @ 10 MHz rate 1 MHz p-p @ 10 MHz rate Channel 2 (FM Auto) Power Meter Specifications 1/Resolution + 30 ms (FM Off) 1 MHz p-p @ 10 MHz rate Frequency range 100 kHz to 50 GHz, sensor dependent. Power range -70 to +44 dBm, sensor dependent. Power sensors supported 8480 series Resolution 0.01 dB in log mode, 0.1% of full scale in linear mode. Display units Absolute dBm or Watts, Relative dB or % Accuracy Instrumentation 0.02 dB or 0.5%. Add power sensor linearity specification for overall system accuracy. Zero set (digital setting capability of zero) Sensor dependent Power reference Power output 1.00 mW. Factory set to 0.7%, traceable to NIST. Accuracy 1.2% worst case ( 0.9 RSS) for one year. Frequency 50 MHz (nominal) Connector N (f) DVM Specifications Function DC Volts Range 50 Vdc Resolution 2 mV Accuracy 0.25% of reading 10 mV Display Replaces frequency display when DVM is activated More detailed specifications at www.agilent.com/find/microwavecounters 195 Microwave Frequency Counters Microwave Frequency Counter w/power meter, 53140 Series (Continued) Internal timebase stability TCXO Standard Frequency 10 MHz 10 MHz External Input 1, 2, 5, 10 MHz 1, 2, 5, 10 MHz Oven Option 001 General information Aging rate Save and recall: Up to 9 complete instrument setups may be saved and later recalled. These setups are retained when power is removed. Per Day Per Month - < 1 x 10-7 < 5 x 10-10 < 1.5 x 10-8 Short term (1 sec. avg. time) < 1 x 10-9 < 2 x 10-10 Line variation (10%) < 1 x 10-7 < 1 x 10-10 Warm-up - < 1 x 10-8 within 5 min. after turn-on at 25C Temperature stability (0-55C) < 1 x 10-6 < 3 x 10-9 Sample rate: User-selectable Fast (nominally 20 ms between readings), Medium (nominally 250 ms between readings), Slow (nominally 1 s between readings) and Hold. Size: 330mm W x 156 mm H x 376 mm Operating temperature: 0-55C With battery option: 0-40C Power Sensors Application Information Weight: 4.5 kg without battery option, 6.6 kg with battery option 8481B 25 W Power Sensor, 18 GHz Warranty: 1 year 8481H 3 W Power Sensor, 18 GHz 4 Hints for Making Better Microwave Counter Measurements This Product Note provides four pertinent hints for making better microwave counter measurements, describes the advantages of using a microwave counter, and deals with the unique measurement problems created by the advancement in counter technology. 5967-6195E Ordering Information 8482B 25 W Power Sensor, 4.2 GHz 8482H 3 W Power Sensor, 4.2 GHz 8485D 100 mW Power Sensor, 26.5 GHz Agilent 53147A 20 GHz Counter/Power Meter/DVM 8485D-033 100 mW Power Sensor, 33 GHz Agilent 53148A 26.5 GHz Counter/Power Meter/ 8482A 100 mW Power Sensor, 4.2 GHz Agilent 53149A 46 GHz Counter/Power Meter/DVM 8481A 100 mW Power Sensor, 18 GHz 8487A 100 mW Power Sensor, 50 GHz Option 001 Oven timebase Option 002 Battery and DC input Option 007 Soft carrying case Option 1CM Rack mounting kit More detailed specifications at www.agilent.com/find/microwavecounters 196 Microwave Frequency Counters Microwave CW Frequency Counter 53150 Series Ultrawide range, single input (from 50 MHz up to 46 GHz) Simultaneous power and measurement with analog indicator GPIB and RS-232 standard Lightweight and rugged 53150A - 53152A Optional battery Abbreviated technical data Input characteristics Convenience, portability and outstanding performance The innovative designs of the Agilent 53150 Series microwave counters offer an uncluttered, feature laden front panel. These designs present no-compromise performance and quality in a surprisingly small, light, battery operated product. Frequency range The convenience of a single microwave input The Agilent 53150 Series has an advanced sampler that integrates a separate zero bias Schottky diode for the accurate measurement of input power. This allows measurement of both frequency and power with a single connection. No compromise in frequency coverage is required for this capability. The ultrawideband microwave input covers the entire RF and microwave spectrum, from intermediate frequencies IFs) of 50 MHz to millimeter waves. Agilent 53150A Agilent 53151A Agilent 53152A Channel 1 Normal mode Low pass filter enabled 10 Hz - 125 MHz 10 Hz - 50 kHz 10 Hz - 125 MHz 10 Hz - 50 kHz 10 Hz - 125 MHz 10 Hz - 50 kHz Channel 2 50 MHz - 20 GHz 50 MHz - 26.5 GHz 50 MHz - 46.0 GHz Channel 1 10-30 Hz 30 Hz-125 MHz 40 mV 25 mV 40 mV 25 mV 40 mV 25 mV Channel 2 50-250 MHz 0.25-12.4 GHz 12.4-18 GHz 18-20 GHz 20-26.5 GHz 26.5-40 GHz 40-46 GHz -20 dBm -33 dBm -33 dBm -29 dBm N/A N/A N/A -20 dBm -33 dBm -33 dBm -29 dBm -25 dBm N/A N/A -20 dBm -33 dBm -30 dBm -27 dBm -27 dBm -23 dBm -17 dBm Channel 1 2 Vrms 2 Vrms 2 Vrms Channel 2 50 MHz - 2 GHz 2-46 GHz +5 dBm +13 dBm +5 dBm +13 dBm +5 dBm +13 dBm Damage level Channel 1/ Channel 2 120 V (DC + AC pk) linearly derated to 5 Vrms at 125 MHz +27 dBm 120 V (DC + AC pk) linearly derated to 5 Vrms at 125 MHz +27 dBm 120 V (DC + AC pk) linearly derated to 5 Vrms at 125 MHz +27 dBm Impedance (Nominal) Sensitivity Maximum input Connector SWR The power measurement accuracy and repeatability of these counters rivals power meters with diode sensors. Channel 1 1 M / 60 pF 1 M / 60 pF 1 M / 60 pF Channel 2 50 50 50 Channel 1 BNC female BNC female BNC female Channel 2 SMA or APC-3.5 compatible female SMA or APC-3.5 compatible female 2.92 mm removable, SMA or APC-3.5 compatible female 1.5:1 typical 2.0:1 typical 3.0:1 typical N/A N/A 1.5:1 typical 2.0:1 typical 3.0:1 typical 3.0:1 typical N/A 1.5:1 typical 2.0:1 typical 3.0:1 typical 2.5:1 typical 2.5:1 typical Channel 2 50-250 MHz 0.25-10 GHz 10-20 GHz 20-26.5 GHz 26.5-46 GHz More detailed specifications at www.agilent.com/find/microwavecounters 197 Microwave Frequency Counters Microwave CW Frequency Counter 53150 Series (Continued) Abbreviated technical data Field tough but ready for bench-top or ATE applications The Agilent 53150 Series is as comfortable in the field as in the laboratory. The rugged case with an integrated tilting handle can tolerate the vibration and shock expected in field use. The backlit LCD display ensures visibility in all environments, from dark to full sunlight, at distances exceeding 15 feet. If AC power is unavailable, the internal, replaceable camcorder batteries provide at least 2.5 hours of continuous operation. The unit can also be powered from an external 11-18 Vdc source. For benchtop and ATE applications, the Agilent 53150 Series delivers full functionality and high measurement speed. The fully programmable RS-232 interface and high speed GPIB interface are standard features. Input characteristics Agilent 53150A Agilent 53151A Agilent 53152A Coupling Channel 1 AC AC AC Channel 2 AC AC AC Acquisition Channel 1 time Channel 2 (1 MHz FM rate) (FM Auto/FM Off) N/A N/A N/A 125 ms/100 ms 125 ms/100 ms 140 ms/115 ms Resolution Channel 1/ Channel 2 1 Hz to 1 MHz 1 Hz to 1 MHz 1 Hz to 1 MHz Emissions ("kickback noise") Channel 1 N/A N/A N/A Channel 2 (measuring/ no input) -40 dBm / <-70 dBm -40 dBm / <-70 dBm -40 dBm / <-70 dBm Residual stability* Channel 1 N/A N/A N/A Channel 2 *Counter and source tied to same timebase 0.6 LSD rms 0.8 LSD rms 1.25 LSD rms Accuracy Channel 1/ Channel 2 1 LSD timebase error x frequency 1 LSD timebase error x frequency 1 LSD timebase error x frequency Measurement time Channel 1 1/Resolution + 20 ms 1/Resolution + 20 ms 1/Resolution + 20 ms Channel 2 1/Resolution + acquisition time + 20 ms 1/Resolution + acquisition time + 20 ms 1/Resolution + acquisition time + 20 ms Channel 1 N/A N/A N/A 20 MHz p-p max @ 10 MHz rate FM tolerance Channel 2 (FM Auto) 20 MHz p-p max (FM Off) @ 10 MHz rate Power measurement 1 MHz p-p @ 10 MHz rate 1 MHz p-p @ 10 MHz rate 20 MHz p-p max to 26.5 GHz, 12 MHz p-p max above 26.5 GHz @ 10 MHz rate 1 MHz p-p @ 10 MHz rate Channel 1 N/A N/A N/A Channel 2 N/A N/A N/A Range Counter sensitivity to +7 dBm Counter sensitivity to +7 dBm Counter sensitivity to +7 dBm Accuracy at input connector** (0 dBm to -20 dBm) 0.05-12.4 GHz 12.4-20 GHz 26.5-46 GHz 1.5 dB 1.5 dB N/A N/A 1.5 dB 1.5 dB 2.0 dB N/A 1.0 dB 1.5 dB 1.5 dB 2.0 dB Resolution 0.01 dB 0.01 dB 0.01 dB Display dBm or milliwatts/ microwatts dBm or milliwatts/ microwatts dBm or milliwatts/ microwatts General information Save and recall: Up to 9 complete instrument setups may be saved and later recalled. These setups are retained when power is removed. Sample rate: User-selectable Fast (nominally 20 ms between readings), Medium (nominally 250 ms between readings), Slow (nominally 1 s between readings) and Hold. Size: 213 mm W x 88.5 mm H x 300 mm Operating temperature: 0-55C With battery option: 0-40C Weight: 4 kg without battery option, 6.4 kg with battery option Warranty: 1 year Programming: GPIB (IEEE-488.1-1987, IEEE 488.2-1987) or RS-232C Language: SCPI-1992.0 (Standard Commands for Programmable Instruments) RS-232C rates: User-selectable 2400 19200 baud More detailed specifications at www.agilent.com/find/microwavecounters 198 Microwave Frequency Counters Microwave CW Frequency Counter 53150 Series (Continued) Internal timebase stability TCXO Standard Frequency 10 MHz 10 MHz External Input 1, 2, 5, 10 MHz 1, 2, 5, 10 MHz - < 1 x 10-7 < 5 x 10-10 < 1.5 x 10-8 Power supply: Aging rate AC: 90-132 Vac; 47.5-66 Hz or 360-440 216-264 Vac; 47.5-66 Hz line selection: automatic power requirements: 75 VA max. (25 W typ.) Per Day Per Month Short term (1 sec. avg. time) Oven Option 001 < 1 x 10-9 < 2 x 10-10 Line variation (10%) < 1 x 10-7 < 1 x 10-10 DC (Option 002 only): 11-18 Vdc; 2A Warm-up - < 1 x 10-8 within 5 min.after turn-on at 25C Battery (Option 002): Temperature (0-55C) stability < 1 x 10-6 < 3 x 10-9 Type: VHS camcorder, lead acid (2 Charge Time: 8 hours in unit Capacity: 2.5 hours min. at 25C Ordering Information Agilent 53150A Microwave frequency counter, 20 GHz Agilent 53151A Microwave frequency counter, 26.5 GHz Agilent 53152A Microwave frequency counter, 46 GHz Options Opt 001 Oven Timebase Opt 002 Battery and DC input Application Information 4 Hints for Making Better Microwave Counter Measurements This Product Note provides four pertinent hints for making better microwave counter measurements, describes the advantages of using a microwave counter, and deals with the unique measurement problems created by the advancement in counter technology. 5967-6195E Drivers None Accessories Battery charger 53150-60217 Spare battery 53150-80010 DC Power input cable 53150-60214 More detailed specifications at www.agilent.com/find/microwavecounters 199 Function/Arbitrary Waveform Generators Selection Guide 33220A Function/Arbitrary Waveform Generator, 20 MHz 33250A Function/Arbitrary Waveform Generator, 80 MHz Frequency range (sine, square) 1 Hz to 20 MHz 1 Hz to 80 MHz Standard waveforms Sine, square, pulse, triangle, ramp, noise, sin(x)/x, exponential rise and fall, cardiac, DC volts Sine, square, pulse, triangle, ramp, noise, sin(x)/x, exponential rise and fall, cardiac, DC volts Arbitrary waveforms 2 to 64 K-points 1 to 64 K-points Sample rate 50 MSa/s 200 MSa/s Modulation AM, FM, PM, FSK, PWM, sweep and burst (all internal/external) AM, FM, FSK, burst (all internal/external) Sweep Linear or logarithmic; up or down Linear or logarithmic; up or down External clock reference Optional External lock range: 10 MHz 500 Hz Internal frequency: 10 MHz Standard External lock range: 10 MHz 35 kHz Internal frequency: 10 MHz Connectivity (Intuilink Software included) GPIB, USB, LAN GPIB, RS-232, Optional USB w/82357A Waveform Generator, 80 MHz More detailed specifications at www.agilent.com/find/power 200 Agilent Function/Arbitrary Waveform Generators Function/Arbitrary Waveform Generator 33220A 20 MHz 20 MHz Sine and Square waveforms Ramp, Triangle, Noise, and DC waveforms 5 MHz pulse with variable edge-time 14-bit, 50 MSa/s, 64 K-point Arbitrary waveforms AM, FM, PM, FSK, and PWM modulation types 33220A Linear & logarithmic sweeps and burst operation LXI class C compliant Specifications (at 0 to 55 C unless otherwise specified) Uncompromising performance for functions and waveforms The Agilent Technologies 33220A Function /Arbitrary Waveform Generator uses direct digital synthesis (DDS) techniques to create a stable, accurate output signal for clean, low distortion sine waves. It also gives you square waves with fast rise and fall times up to 20 MHz and linear ramp waves up to 200 kHz. Waveforms Waveform Characteristics Standard Sine, Square, Ramp, Triangle, Pulse, Noise, DC Built-in arbitrary Exponential rise, Exponential fall, Negative ramp, Sin(x)/x, Cardiac Sine Frequency Range 1 Hz to 20 MHz Amplitude Flatness 1, 2 (relative to 1 kHz) < 100 kHz 100 kHz to 5 MHz 5 MHz to 20 MHz 0.1 dB 0.15 dB 0.3 dB Harmonic distortion2, 3 DC to 20 kHz 20 kHz to 100 kHz 100 kHz to 1 MHz 1 MHz to 20 MHz < 1 VPP 1 VPP -70 dBc -65 dBc -50 dBc -40 dBc -70 dBc -60 dBc -45 dBc -35 dBc Spurious (non-harmonic)2, 4 DC to 1 MHz 1 MHz to 20 MHz Pulse generation The 33220A can generate variableedge-time pulses up to 5 MHz. With variable period, pulse width, and amplitude the 33220A is ideally suited to a wide variety of applications requiring a flexible pulse signal. Square Custom waveform generation Use the 33220A to generate complex custom waveforms. With 14-bit resolution, and a sampling rate of 50 MSa/s, the 33220A gives you the flexibility to create the waveforms you need. It also lets you store up to four waveforms in nonvolatile memory. Ramp, Triangle Pulse -70 dBc -70 dBc + 6 dB/octave Frequency range 1 Hz to 20 MHz Rise/Fall time < 13 ns Overshoot < 2% Variable duty cycle 20% to 80% (to 10 MHz) 40% to 60% (to 20 MHz) Frequency range 1 Hz to 200 kHz Linearity < 0.1% of peak output Variable Symmetry 0.0% to 100.0% Frequency range 500 Hz to 5 MHz Pulse width (period 10s) 20 ns minimum, 10 ns resolution Variable edge time < 13 ns to 100 ns Noise Bandwidth 10 MHz typical Arbitrary Frequency range 1 Hz to 6 MHz Waveform length 2 to 64 K points Amplitude resolution 14 bits (including sign) Sample rate 50 MSa/s Non-volatile memory four waveforms More detailed specifications at www.agilent.com/find/33220A 201 Agilent Function/Arbitrary Waveform Generators Function/Arbitrary Waveform Generator 33220A 20 MHz (Continued) Specifications (at 0 to 55 C unless otherwise specified) Common Characteristics Easy-to-use functionality Front-panel operation of the 33220A is straight-forward and user friendly. You can access all major functions with a single key or two. The knob or numeric keypad can be used to adjust frequency, amplitude, offset, and other parameters. You can even enter voltage values directly in Vpp, Vrms, dBm, or as high and low levels. Timing parameters can be entered in Hertz (Hz) or seconds. Resolution 1 Hz Amplitude Range 10 mVPP to 10 VPP into 50 20 mVPP to 20 VPP into open circuit Accuracy 1, 2 (at 1 kHz) 1% of setting 1 mVPP DC Offset Main Output Internal AM, FM, PM, FSK, and PWM modulation make it easy to modulate waveforms without the need for a separate modulation source. Linear and logarithmic sweeps are also built in, with sweep rates selectable from 1 ms to 500 s. Burst mode operation allows for a user-selected number of cycles per period of time. GPIB, LAN, and USB interfaces are all standard, plus you get full programmability using SCPI commands. External frequency reference (Option 001) The 33220A external frequency reference lets you synchronize to an external 10 MHz clock, to another 33220A, or to an Agilent 33250A. Phase adjustments can be made from the front panel or via a computer interface, allowing precise phase calibration and adjustment. Frequency Internal Frequency Reference External Frequency Reference (Option 001) Units VPP, Vrms, dBm Resolution 4 digits Range (peak AC + DC) 5 V into 50 10 V into open circuit Accuracy 1, 2 2% of offset setting 0.5% of amplitude 2 mV Resolution 4 digits Impedance 50 typical Isolation 42 Vpk maximum to earth Protection Short-circuit protected, overload automatically disables main output Accuracy 5 10 ppm in 90 days 20 ppm in 1 year Rear Panel Input Lock Range Level 10 MHz 500 Hz 100 mVPP to 5 VPP Impedance 1 k typical, AC coupled Lock Time Rear Panel Output < 2 seconds Frequency 10 MHz Level 632 mVPP (0 dBm), typical Impedance 50 typical, AC coupled Phase Offset Range + 360 to - 360 Resolution 0.001 Accuracy Modulation AM, FM, FSK PM External Modulation Input 6 (for AM, FM, PM, PWM) Carrier waveforms 20 ns Sine, Square, Ramp, Arb Source Internal/External Internal modulation Sine, Square, Ramp, Triangle, Noise, Arb (2 mHz to 20 kHz) Depth 0.0% to 120.0% Carrier waveforms Sine, Square, Ramp, Arb Source Internal/External Internal modulation Sine, Square, Ramp, Triangle, Noise, Arb (2 mHz to 20 kHz) Deviation 0.0 to 360.0 degrees Voltage range 5 V full scale Input impedance 5 k typical Bandwidth DC to 20 kHz More detailed specifications at www.agilent.com/find/33220A 202 Agilent Function/Arbitrary Waveform Generators Function/Arbitrary Waveform Generator 33220A 20 MHz (Continued) Specifications (at 0 to 55 C unless otherwise specified) Sweep Connectivity The Agilent IntuiLink Arbitrary Waveform software allows you to easily create, edit, and download complex waveforms using the waveform editor. Or you can capture a waveform using IntuiLink for Oscilloscope and send it to the 33220A for output. To find out more about IntuiLink, visit www.agilent.com/find/intuilink. Burst 7 General Software Driver: * SCPI * VXIPlug&Play * IVI.com Waveforms Sine, Square, Ramp, Arb Type Linear or Logarithmic Direction Up or Down Sweep time 1 ms to 500 s Trigger Single, External, or Internal Marker falling edge of sync signal (programmable frequency) Waveforms Sine, Square, Ramp, Triangle, Pulse, Noise, Arb Type Counted (1 to 50,000 cycles), Infinite, Gated Start/Stop Phase -360 to +360 Internal Period 1 s to 500 s Gate Source External trigger Trigger source Single, External or Internal Power Supply CAT II 100 - 240 V @ 50/60 Hz (-5%, +10%) 100 - 120 V @ 400 Hz (10%) Power Consumption 50 VA max Operating Temperature 0C to 55C Interface USB, GPIB, and LAN standard Ordering Information Language SCPI - 1993, IEEE-488.2 Agilent 33220A 20 MHz Function/Arbitrary Wavefrom Generator Dimensions Bench top Rack mount (W x H x D) 261.1 mm x 103.8 mm x 303.2 mm 212.8 mm x 88.3 mm x 272.3 mm Weight 3.4 kg (7.5 lbs) Warranty 1 year Accessories included Operating manual, service manual, quick reference guide, IntuiLink waveform editor software, test data, USB cable, and power cord. Agilent Model: 33220A Top Options Opt. 001 Opt. 0B0 Opt. 1CM Opt. A6J 272.3mm External frequency reference Delete manual Rackmount kit (also sold as Agilent 34190A) ANSI Z540 calibration Other Accessories 34131A 34161A 34190A 212.8mm Carrying case Accessory pouch Rackmount kit Footnotes: 1 add 1/10th of output amplitude and offset spec per C for operation outside the range of 18C to 28C 2 Autorange enabled 3 DC offset set to 0 V 4 spurious output at low amplitude is -75 dBm typical 5 add 1 ppm/C average for operation outside the range of 18C to 28C 6 FSK uses trigger input (1 MHz maximum) 7 Sine and square waveforms above 6 MHz are allowed only with an "infinite" burst count 88.3mm Rear 303mm Side More detailed specifications at www.agilent.com/find/33220A 203 Agilent Function/Arbitrary Waveform Generators Function/Arbitrary Waveform Generator 33250A 80 MHz 80 MHz sine and square waveforms Ramp, triangle noise and other waveforms 50 MHz pulse waveforms with variable edge time 12-bit, 200 MSa/s, 64K-point deep arbitrary waveform 33250A AM, FM, PM, FSK linear & logarithmic sweeps and burst Specifications (at 0 to 55 C unless otherwise specified) Standard Waveforms The Agilent Technologies 33250A Function/Arbitrary Waveform Generator uses direct digitalsynthesis techniques to create a stable, accurate output on all waveforms, down to 1 Hz frequency resolution. The benefits are apparent in every signal you produce, from the sine wave frequency accuracy to the fast rise/fall times of square waves, to the ramp linearity. Front-panel operation of the 33250A is straightforward and user friendly. The knob or numeric keypad can be used to adjust frequency, amplitude and offset. You can even enter voltage values directly in Vpp, Vrms, dBm, or high/low levels. Timing parameters can be entered in hertz (Hz) or seconds. Custom Waveform Generation Why settle for a basic function generator when you can get arbitrary waveforms at no extra cost? With the 33250A, you can generate arbitrary waveforms with 12-bit vertical resolution, 64K memory depth, and a sample rate of 200 MSa/s. You can also store up to four 64K-deep arbitrary waveforms in non-volatile memory with user-defined names to help you find the right waveform when you need it most. Waveforms Frequency Characteristics Sinewave Spectral Purity Standard sine, square, pulse, ramp, noise, sin(x)/x, exponential rise, exponential fall, cardiac, DC volts Arbitrary Waveform length 1 to 64K points Amplitude resolution 12 bits (including sign) Repetition rate 1 Hz to 25 MHz Sample rate 200 MSa/s Filter bandwidth 50 MHz Non-vol. memory Four (4) 64K waveforms Sine 1 Hz to 80 MHz Square 1 Hz to 80 MHz Pulse 500 Hz to 50 MHz Arb 1 Hz to 25 MHz Ramp 1 Hz to 1 MHz White noise 50 MHz bandwidth Resolution 1 Hz; except pulse, 5 digits Accuracy (1 year) 2 ppm, 18C to 28C 3 ppm, 0C to 55C Harmonic distortion 3 Vpp1 > 3 Vpp DC to 1 MHz -60 dBc -55 dBc 1 to 5 MHz -57 dBc -45 dBc 5 to 80 MHz -37 dBc -30 dBc Spurious (non-harmonic)2 Signal Characteristics Squarewave Pulse DC to 1 MHz -60 dBc 1 to 20 MHz -50 dBc 20 to 80 MHz -50 dBc + 6 dBc/octave Rise/Fall time < 8 ns Overshoot < 5% Asymmetry 1% of period + 1 ns Period 20.00 ns to 2000.0 s Pulse width 8.0 ns to 1999.9 s Variable edge time 5.00 ns to 1.00 ms More detailed specifications at www.agilent.com/find/33250A 204 Agilent Function/Arbitrary Waveform Generators Function/Arbitrary Waveform Generator 33250A 80 MHz (Continued) Specifications (at 0 to 55 C unless otherwise specified) Signal Characteristics (Continued) Pulse Generation The 33250A can generate simple pulses up to 50 MHz. With variable edge time, pulse width and voltage level, the 33250A is ideally suited to a wide variety of pulse applications. Ramp Arb Output Characteristics < 0.1% of peak output Symmetry 0.0% - 100.0% Min. edge time < 10 ns Linearity < 0.1% of peak output Settling time < 50 ns to 0.5% of final value Amplitude (into 50 ) 10 mVpp to 10 Vpp Accuracy (at 1 kHz, >10 mVpp, 1% of setting Autorange) 1 mVpp Built-in Versatility AM, FM and FSK capabilities make it easy to modulate waveforms with or without a separate source. Linear or logarithmic sweeps can be performed with a programmable frequency marker signal. Programmable burst count and gating allow you to further customize your signal. Flatness (sinewave relative to 1 kHz, Autorange) Waveform Output < 10 MHz 10 to 50 MHz 50 to 80 MHz Units Vpp, Vrms, dBm, high and low level Resolution 0.1 mV or 4 digits Accuracy 1% of setting + 2 mV + 0.5% of amplitude Impedance 50 typical (fixed) Offset (into 50 ) Color Graphical Display The unique design of the 33250A combines a low-profile instrument with the benefits of a color graphical display. Now you can display multiple waveform parameters at the same time. The graphical interface also allows you to modify arbitrary waveforms quickly and easily. Timebase Stability and Clock Reference The 33250A TCXO timebase gives you frequency accuracy of 2 ppm for your most demanding applications. The external clock reference input/output lets you synchronize to an external 10 MHz clock, to another 33250A, or to an Agilent 33220A. Phase adjustments can be made from the front panel or via a computer interface, allowing precise phase calibration and adjustment. Linearity 1% (0.1 dB) 2% (0.2 dB) 5% (0.4 dB) 5 Vpk AC + DC >10 M (output disabled) Modulation AM, FM FSK External Modulation Input Burst Sweep Isolation 42 Vpk maximum to earth Protection short-circuit protected; overload automatically disables main output Carrier waveforms sine, square, ramp, and arb Mod. waveforms sine, square, ramp, noise, and arb Mod. frequency 2 mHz to 20 kHz Source internal/external Carrier waveforms sine, square, ramp, and arb Mod. waveform 50% duty cycle square Internal rate 2 mHz to 1 MHz Frequency range 1 Hz to 80 MHz Source internal/external Voltage range 5 V full scale Input impedance 10 k Frequency DC to 20 kHz Waveforms sine, square, ramp, pulse, arb, and noise Frequency 1 Hz to 80 MHz3 Burst count 1 to 1,000,000 cycles or infinite Waveforms sine, square, ramp, and arb Type linear and logarithmic Direction up or down More detailed specifications at www.agilent.com/find/33250A 205 Agilent Function/Arbitrary Waveform Generators Function/Arbitrary Waveform Generator 33250A 80 MHz (Continued) Specifications (at 0 to 55 C unless otherwise specified) System Characteristics Clock Reference Phase Offset Connectivity For system applications, both GPIB and RS-232 interfaces are standard, and support full programmability using SCPI commands. The included Agilent IntuiLink software allows you to easily create, edit, and download complex waveforms using the intuiLink Arbitrary Waveform Editor. Or you can capture a waveform using IntuiLink oscilloscope or DMM and send it to the 33250A for output. For programmers, ActiveX components can be used to control the instrument using SCPI commands. IntuiLink provides the tools to easily create, download, and manage wave-forms for your 33250A. Software Driver: * SCPI * VXIPlug&Play * IVI.com Ordering Information Agilent 33250A 80 MHz Function/Arbitrary Wavefrom Generator External Reference Input Range -360 to +360 Resolution 0.001 Lock range 10 MHz 35 kHz Level 100 mVpp to 5 Vpp Impedance 1 k nominal, AC coupled Lock time <2s Internal Reference Output Frequency Sync Output General 10 MHz Level 632 mVpp (0 dbm), nominal Impedance 50 nominal, AC coupled Level TTL compatible into > 1 k Impedance 50 nominal Power supply 100-240 V, 50-60 Hz 100-127 V, 50-400 Hz Power consumption 140 VA Operating temp. 0C to 55C Stored states 4 named user configurations Interface IEEE-488 and RS-232 std. Language SCPI-1997, IEEE-488.2 Dimensions Notes: (WxHxD) Bench top 254 x 104 x 374 mm Rackmount 213 x 89 x 348 mm Weight 4.6 kg Warranty 1 year 1 Harmonic distortion at low amplitudes is limited by a -70 dBm floor 2 Spurious noise at low amplitudes is limited by a -75 dBm floor 3 Sine and square waveforms above 25 MHz only with infinite burst count Agilent Model: 33250A Top 374.0mm Accessories included Operating manual, service manual, quick reference guide, IntuiLink waveform editor software, test data, RS-232 cable, and power cord. Options Opt. 0B0 Opt. 1CM Opt. A6J Delete manual Rackmount kit (also sold as Agilent 34190A) ANSI Z540 calibration 213.0mm Other Accessories 82357A 34131A 34161A 34190A Optional USB Carrying case Accessory pouch Rackmount kit* 88.5mm * For racking two 33250As side-by-side, order the following items: Lock-link kit (p/n 5061-9694), Flange kit (p/n 5063-9212) Rear 348.3mm Side More detailed specifications at www.agilent.com/find/33250A 206 VXI Instruments, 3499 Switch Solutions and Connectivity Products Agilent VXI Instruments and Solutions Agilent provides more full-featured VXI instrument modules than any other industry-wide open standard architecture. Instruments include C-size and B-size mainframes, multimeters, counters, power meters, digitizers, arbitrary waveform generators, switches, and interfaces. VXI is an ideal solution for systems that require extensive switching with other high-performance instruments - Agilent offers large channel count multiplexers, matrix, and RF switches. You can get complete details including specifics and price at: www.agilent.com/find/vxi For new system development Agilent offers the 34980A a lower cost solution. Agilent Hardware and Software for Connectivity Agilent offers a complete line of cards and converters for GPIB, USB, RS232, and LAN. Software solutions allow you to quickly connect to any instrument from any vendor, and then combine graphical and textual programming tools to measure, test, and analyze data. Agilent's software applications include VEE Pro, T&M Toolkit, IO Libraries Suite, and IntuiLink. Our software products are part of the Agilent Open family of products featuring open software, system-ready instruments and PC-standard I/O. Agilent Open products give you the freedom to choose the right tools for your test solution and the assurance that they will all work together, every time. For complete details see www.agilent.com/find/connectivity Agilent's 3499 Series Switch Solutions Agilent's 3499 Series of switches provide a scalable solution with a choice of three mainframes and over 30 switch modules. Switch signals from DC to light- wave, along with RF, 1000 V, or 8 A of current. All mainframe configurations of the 3499 can scan at rates up to 350 channels per second or open/close 200 channels in less than 0.1 second. Programmable control is provided via either RS-232 or GPIB. For complete details see www.agilent.com/find/3499 For new system development Agilent offers the 34980A a lower cost solution. 34980A A Lower Cost Switch Measure Solution The 34980A is an 8-slot mainframe that has an optional built-in DMM and your choice of 19 plug-in modules including switching from DC 20 GHz, digital I/O, D/A converters, and counters. It's ideal for medium to high-density switching and can be more cost effective than the 34970A in some applications. Complete product details for the 34980A can be found at www.agilent.com/find/34980A More detailed specifications at www.agilent.com/find/power 207 Agilent Model Number Index Agilent Model Number Page Number Agilent Model Number Page Number 14565A 86 6613C 32 33220A 201 6614C 32 33250A 204 6621A 65 34401A 175 6622A 65 34405A 171 6623A 65 34410A 178 6624A 65 34411A 178 6625A 67 34420A 184 6626A 67 3458A 187 6627A 65 34970A 151 6628A 67 34980A 159 6629A 67 3499A 190 6631B 34 53131A 191 6632B 34 53132A 191 6633B 34 53147A 194 6634B 34 53148A 194 6641A 36 53149A 194 6642A 36 53150A 197 6643A 36 53151A 197 6644A 36 53152A 197 6645A 36 53181A 191 6651A 42 6030A 23 6652A 42 6031A 23 6653A 42 6032A 23 6654A 42 6033A 23 6655A 42 6035A 23 6671A 50 6038A 23 6672A 50 6060B 99 6673A 50 6063B 99 6674A 50 6541A 39 6675A 50 6542A 39 6680A 61 6543A 39 6681A 61 6544A 39 6682A 61 6545A 39 6683A 61 6551A 46 6684A 61 6552A 46 6690A 63 6553A 46 6691A 63 6554A 46 6692A 63 6555A 46 6811B 108 6571A 57 6812B 108 6572A 57 6813B 108 6573A 57 66101A 76 6574A 57 66102A 76 6575A 57 66103A 76 6611C 32 66104A 76 6612C 32 66105A 76 More detailed specifications at www.agilent.com/find/power 208 Agilent Model Number Index (Continued) Agilent Model Number Page Number Agilent Model Number Page Number 66106A 76 N3307A 94 66309B/D 81 N5741A 26 66311B 81 N5742A 26 66319B/D 81 N5743A 26 66321B/D 81 N5744A 26 66332A 81 N5745A 26 E3610A 15 N5746A 26 E3611A 15 N5747A 28 E3612A 15 N5748A 28 E3614A 15 N5749A 28 E3615A 16 N5750A 28 E3616A 16 N5751A 28 E3617A 16 N5752A 28 E3620A 17 N5761A 29 E3630A 17 N5762A 29 E3631A 18 N5763A 29 E3632A 19 N5764A 29 E3633A 19 N5765A 29 E3634A 19 N5766A 29 E3640A 21 N5767A 30 E3641A 21 N5768A 30 E3642A 21 N5769A 30 E3643A 21 N5770A 30 E3644A 21 N5771A 30 E3645A 22 N5772A 30 E3646A 22 N6731B 72 E3647A 22 N6732B 72 E3648A 22 N6733B 72 E3649A 22 N6734B 72 E4350B 88 N6735B 72 E4351B 88 N6736B 72 E4356A 55 N6741B 74 L4421A 140 N6742B 74 L4433A 141 N6743B 74 L4437A 142 N6744B 74 L4445A 143 N6745B 74 L4450A 145 N6746B 74 L4451A 147 N6751A 69 L4452A 149 N6752A 69 N3300A 97 N6761A 69 N3301A 97 N6762A 69 N3302A 94 N6773A 71 N3303A 94 N6774A 71 N3304A 94 N6775A 71 N3305A 94 N6776A 71 N3306A 94 More detailed specifications at www.agilent.com/find/power 209 Agilent Replacement Guide Index for Obsolete Agilent System and Bench Products * These products are closest in ratings to the discontinued model, but are not identical. Refer to the catalog for the features and specifications of the suggested alternative products. Obsolete Model Number Closest Alternatives* Obsolete Model Number Closest Alternatives* 6002A 664xA 6266B 6543A 6010A 6030A 6267B 6553A 6011A 6031A 6268B 6574A 6012B 6032A 6269B 6573A 6015A 6035A 6271B 6544A 6023A 6033A 6274B 6574A 6024A 6038A 6281A E3614A 6028A 6038A 6282A 6542A 6034A 6038A 6284A E3615A 6050A N3300A 6286A 6542A 6051A N3301A 6289A E3616A 6200B E3616A 6291A 6543A 6201B E3616A 6294A E3617A 6202B E3616A 6296A 6544A 6203B E3614A 6299A 6634B or (2) E3617A 6204B E2617A 6384A 6542A 6205C (2) E3611A 6427B 6552A 6206C E3617A 6428B 6011A 6211A E3612A 6433B 6012B 6212C E3612A 6434B 6012B 6213A E3610A 6438B 6544A, 6634B 6214C E3610A 6439B 6012B 6215A E3611A 6448B 6015A 6216C E3611A 6453B (2) 6572A 6217A E3612A 6456B (2) 6572A 6218C E3612A 6459A (2) 6573A 6220B E3617A 6464C (2) 6681A 6224B 6453A 6466C (2) 6681A 6226B 6544A 6612B 6612C 6227B (2) E3616A 6632A 6632B 6228B (2) E3617A 6633A 6633B 6234A E3620A 6634A 6634B 6235A E3630A 6814A/B 6813B 6236B E3630A 6834A/B 6813B 6237B E3611A and E3620A 60501B N3302A 6253A (2) E3615A 60502B N3304A 6255A (2) E3616A 60503B N3303A 6256B E6552A 60504B N3306A 6259B 6572A 60507B N3305A 6260B 6572A 66111A 66311B 6261B 6573A 66311A 66311B 6263B 6542A 66311D 66321D 6264B 6552A E4350A E4350B 6265B 6554A More detailed specifications at www.agilent.com/find/power 210 Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open is a versatile combination of test system hardware, I/O and software tools. It accelerates the creation of streamlined test systems that are easy to enhance and maintain by giving you greater choice in measurements, connectivity and programming. Utilizing these advantages, your team has more time to focus on what matters most-- the performance, reliability and delivery of your product. www.agilent.com Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support y ou need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at: Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extracost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. Detailed specifications, application briefs and more for: DC Power Supplies DC Electronic Loads AC Power Solutions Digital Multimeters/Voltmeters www.agilent.com/find/contactus Function/Arbitrary Phone or Fax United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Waveform Generators Data Acquisition and Switching System and Bench Instruments Catalog www.agilent.com/find/open Agilent Technologies' Test and Measurement Support, Services, and Assistance Frequency Counters LXI System and Bench Instruments Catalog July 2006 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com Contacts revised: 09/26/05 Product specifications and descriptions in this document subject to change without notice. Bluetooth and the Bluetooth logos are trademarks owned by BluetoothSIG, Inc., USA, and licensed to Agilent Technologies, Inc. Microsoft(R) and Windows(R) are U.S. registered trademarks of Microsoft(R) Corporation LabVIEW TM is a U.S. registered trademark of National Instruments Corporation (c) Agilent Technologies, Inc. 2006 Printed in USA, July 30, 2006 5989-4702EN July 2006 SPDCvr_LoRz.indd 1 7/25/06 5:03:35 PM