HP
ORDERING INFORMATION
Relay for control panel of
10A (2c/3c/4c) HP RELAYS
FEATURES
1. High-capacity and long life
Mechanical life is more than 10 million
operations and, with electrical life of more
than 200,000 operations (resistive load
10 A; inductive load 7.5 A), the relay has
excellent inductive load durability.
2. Easy mounting and wiring
The terminal arrangement is apparent at
a glance and wiring is easy. Moreover,
quick tab terminal is also possible.
3. Operation indicator option
Optional operation indicators are
available f or easy visual confirmation that
relays are operating. They simplify
maintenance.
4. Wide range of sockets and terminal
sockets
To enable use with DIN rails, DIN
terminal sockets are also available.
TYPICAL APPLICATIONS
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
Applications include:
1. Industrial machinery
For controlling positioning, pressure, and
temperature in molding equipment,
boilers, pumps, charging pressure
equipment, measuring and evaluation
equipment, textile machines, etc.
2. Machine tools
Control of positioning and directional
change in turning machines, lathes,
borers, etc.
3. Food processing packing machines
Automatic control of packing equipment
for milk and seafood, bottling, canning,
and packaging
4. Office equipment
Control of copiers, time recorders, etc.
5. Coin operate machines
Control of food, cigarette, and other
vending machines
6. Measuring devices and equipment
For repeating installation of control
signals and in power amplifiers
7. Generators, transformers and
power receiving equipment.
Functional parts in protective equipment,
functional assistance in automatic
adjustment equipment, telemeters and
other remote monitoring equipment
8. Control of conveyance equipment
Control panels for elevators, escalators,
and other conv ey ance equipment, control
of all kinds industrial transport equipment
such as conveyors.
9. Amusement equipment
Control of equipment in amusement
parks, etc., control of bowling alley
equipment, control of fountains in public
parks
Contact arrangement
2: 2 Form C
3: 3 Form C
4: 4 Form C
HP
Operation indication
Nil:
L: Without indication
With indication
Contact material
F:
Nil: 4 Form C, Silver alloy (cadmium-free)
2 Form C, 3 Form C (Silver)
With LED indicator type
Nominal coil voltage:
With neon lamp type
Nominal coil voltage:
24 V AC
12, 24, 48 V DC
100, 115, 200, 220, 240 V AC
100, 110 V DC
Terminal arrangement
Nil:
TM:
M:
Plug-in terminal
TM type (2 Form C only)
Direct mounting (3 Form C only)
Nominal coil voltage
AC
DC 24, 48, 100, 115, 200, 220, 240 V
12, 24, 48, 100, 110 V
ASCTB81E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
RoHS compliant
HP
TYPES
1. Plug-in type
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
2. Plug-in type (with operation indication)
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
3. TM type and Direct mount type
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
4. Direct mount type (with LED indication)
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
Notes: 1. Standard packaging is handled in units of inner cartons. Please specify if you require inner cartons to be boxed.
2. Sockets, terminal sockets and installation brackets are not included. Please order these separately.
3. For products compliant with international standards, please refer to the standards chart.
* For sockets and terminal sockets, see page 117.
Nominal coil voltage 2 Form C 3 Form C 4 Form C
Part No. Part No. Part No.
24V AC HP2-AC24V HP3-AC24V HP4-AC24V-F
48V AC HP2-AC48V HP3-AC48V HP4-AC48V-F
100V AC HP2-AC100V HP3-AC100V HP4-AC100V-F
115V AC HP2-AC115V HP3-AC115V HP4-AC115V-F
200V AC HP2-AC200V HP3-AC200V HP4-AC200V-F
220V AC HP2-AC220V HP3-AC220V HP4-AC220V-F
240V AC HP2-AC240V HP3-AC240V HP4-AC240V-F
12V DC HP2-DC12V HP3-DC12V HP4-DC12V-F
24V DC HP2-DC24V HP3-DC24V HP4-DC24V-F
48V DC HP2-DC48V HP3-DC48V HP4-DC48V-F
100V DC HP2-DC100V HP3-DC100V HP4-DC100V-F
110V DC HP2-DC110V HP3-DC110V HP4-DC110V-F
Nominal coil voltage 2 Form C 3 Form C 4 Form C
Part No. Part No. Part No.
With LED indication 24V AC HP2-L-AC24V HP3-L-AC24V HP4-L-AC24V-F
With neon lamp
100V AC HP2-L-AC100V HP3-L-AC100V HP4-L-AC100V-F
115V AC HP2-L-AC115V HP3-L-AC115V HP4-L-AC115V-F
200V AC HP2-L-AC200V HP3-L-AC200V HP4-L-AC200V-F
220V AC HP2-L-AC220V HP3-L-AC220V HP4-L-AC220V-F
240V AC HP2-L-AC240V HP3-L-AC240V HP4-L-AC240V-F
With LED indication 12V DC HP2-L-DC12V HP3-L-DC12V HP4-L-DC12V-F
24V DC HP2-L-DC24V HP3-L-DC24V HP4-L-DC24V-F
48V DC HP2-L-DC48V HP3-L-DC48V HP4-L-DC48V-F
With neon lamp 100V DC HP2-L-DC100V HP3-L-DC100V HP4-L-DC100V-F
110V DC HP2-L-DC110V HP3-L-DC110V HP4-L-DC110V-F
Nominal coil voltage 2 Form C (TM type) 3 Form C (direct mount type)
Part No. Part No.
24V AC HP2-TM-AC24V HP3-M-AC24V
48V AC HP2-TM-AC48V HP3-M-AC48V
100V AC HP2-TM-AC100V HP3-M-AC100V
115V AC HP2-TM-AC115V HP3-M-AC115V
200V AC HP2-TM-AC200V HP3-M-AC200V
220V AC HP2-TM-AC220V HP3-M-AC220V
240V AC HP2-TM-AC240V HP3-M-AC240V
12V DC HP2-TM-DC12V HP3-M-DC12V
24V DC HP2-TM-DC24V HP3-M-DC24V
48V DC HP2-TM-DC48V HP3-M-DC48V
100V DC HP2-TM-DC100V HP3-M-DC100V
110V DC HP2-TM-DC110V HP3-M-DC110V
Nominal coil voltage 3 Form C
Part No.
With neon lamp
100V AC HP3-ML-AC100V
115V AC HP3-ML-AC115V
200V AC HP3-ML-AC200V
220V AC HP3-ML-AC220V
240V AC HP3-ML-AC240V
100V DC HP3-ML-DC100V
110V DC HP3-ML-DC110V
ASCTB81E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
HP
RATING
1. Coil data
1) AC coils
2) DC coils (20°C 68°F)
Notes: 1. The nominal current area is ±15% (60Hz) [AC coils],. ±10% (20°C) [DC coils]
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
3. The relay oper ates in a range of 80% to 110% V of the nominal coil voltage, b ut ideally, in consideration of temporary voltage fluctuations, it should be oper ated at
the nominal coil voltage . In particular, for AC oper ation, if the impressed v oltage drops to 80% V or more below the nominal coil voltage , humming will occur and a
large current will flow leading possibly to coil burnout.
4. For use with 200 V DC, connect a 6.7k (10W) resistor, in series, to the 100 V DC relay [3 Form C type is .6.4k (5W); 4 Form C type is .6.2k (10W)].
5. As a general rule, only a pure DC voltage should be used for the coil drive. However, a DC power supply that contains ripples has characteristics that differ from
pure DC. Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.
Contact
arrangement Nominal coil
voltage
Nominal operating
current (mA) Nominal operating
power (VA) Inductance
(H) Pick-up voltage
(at 20°C 68°F)Drop-out voltage
(at 20°C 68°F)
Max. applied
voltage
(at 20°C 68°F)
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
2 Form C
24V AC 94mA 78mA 2.25VA 1.9VA 0.753 0.776
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
48V AC 46.5mA 39mA 2.23VA 1.9VA 3.055 3.106
100V AC 25.3mA 21mA 2.36VA 2.1VA 12.60 12.03
115V AC 23.1mA 18mA 2.31VA 2.1VA 16.70 15.83
200V AC 12.4mA 11mA 2.48VA 2.2VA 48.03 45.81
220V AC 10.6mA 9.5mA 2.34VA 2.1VA 61.28 57.90
240V AC 10.0mA 9.0mA 2.40VA 2.2VA 69.00 66.26
3 Form C
24V AC 148.7mA 130mA 3.56VA 3.1VA 0.0494 0.475
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
48V AC 74.2mA 65mA 3.56VA 3.1VA 1.976 1.899
100V AC 36.4mA 32mA 3.64VA 3.2VA 8.500 8.038
115V AC 32.5mA 28.5mA 3.74VA 3.3VA 10.79 10.36
200V AC 18.2mA 16mA 3.65VA 3.2VA 33.53 32.10
220V AC 16.0mA 14.2mA 3.54VA 3.1VA 41.35 39.32
240V AC 15.8mA 13.9mA 3.79VA 3.3VA 45.94 44.05
4 Form C
24V AC 229mA 200mA 5.49VA 4.8VA 0.320 0.309
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
48V AC 108mA 95mA 5.18VA 4.6VA 1.348 1.292
100V AC 57.3mA 50mA 5.73VA 5.0VA 5.348 5.156
115V AC 47.6mA 42mA 5.47VA 4.8VA 7.264 6.953
200V AC 28.5mA 25mA 5.69VA 5.0VA 21.27 20.45
220V AC 23.8mA 21mA 5.24VA 4.6VA 27.75 26.57
240V AC 23.3mA 20.5mA 5.58VA 4.9VA 30.98 29.75
Contact
arrangement Nominal coil
voltage Nominal current
(mA) Nominal operating
power (W) Coil resistance
()Pick-up voltage
(at 20°C 68°F)Drop-out voltage
(at 20°C 68°F)
Max. applied
voltage
(at 20°C 68°F)
2 Form C
12V DC 109mA 1.3W 110
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
24V DC 54.5mA 1.3W 440
48V DC 26.7mA 1.3W 1,800
100V DC 14.9mA 1.5W 6,700
110V DC 15.0mA 1.7W 7,300
3 Form C
12V DC 120mA 1.4W 100
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
24V DC 60mA 1.4W 400
48V DC 31mA 1.5W 1,560
100V DC 15.6mA 1.6W 6,400
110V DC 14.9mA 1.6W 7,450
4 Form C
12V DC 127mA 1.5W 95
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
24V DC 63mA 1.5W 380
48V DC 32.0mA 1.5W 1,500
100V DC 16.3mA 1.6W 5,950
110V DC 15.7mA 1.7W 7,000
ASCTB81E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
HP
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Electrical life
1) AC load
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
2) DC load
Notes: 1. For DC inductive loads, use an arc suppressing circuit.
2. Cautions at DC load use
When used under a DC load operating at high repetition rate with considerable arcing, corrosion of the contacts and/or the contact blades is likely to occur.
Characteristics Item Specifications
Contact
Arrangement 2 Form C, 3 Form C, 4 Form C
Contact resistance (Initial) Max. 15 m (By voltage drop 6 V DC 1A)
Contact material 2 Form C, 3 Form C Ag
4 Form C Ag alloy (cd free)
Rating Nominal switching capacity 10A 250V AC (resistive load)
Min. switching capacity (Reference value)*1100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
Between contact sets 1,500 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
Between contact and coil 1,500 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
Temperature rise (coil) Max. 65°C 149°F (By temperature method, at 40°C, nominal current)
Operate time*2Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C)
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time*2Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C)
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 2 mm
Expected life Mechanical Min. 107
Conditions Conditions for operation, transport and storage*3Ambient temperature: –50°C to +40°C –58°F to +104°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. Operating speed 20 times/min. (at max. rating)
Unit weight 2 Form C: approx. 60g 2.12oz, 3 Form C: approx. 100g 3.53oz, 4 Form C: approx. 125g 4.41oz
Voltage 125V AC 250V AC Expected life
Load Resistive load (A) (cosϕ=1) Inductive load (A) (cosϕ=0.4) Resistive load (A) (cosϕ=1) Inductive load (A) (cosϕ=0.4)
Current
——10 7.5 Min. 2×105
10 7.5 7.5 5 Min. 5×105
5332Min. 106
10.7 0.6 0.4 Min. 2×106
Voltage 24V DC 125V DC Expected life
Load Resistive load (A) Inductive load (A) Resistive load (A) Inductive load (A)
Current
—7—Min. 2×105
7.5 5 0.5 0.4 Min. 5×105
530.3 0.2 Min. 106
10.6 0.1 0.06 Min. 2×106
ASCTB81E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
HP
4. Life of LED and neon lamp (with operation indication)
REFERENCE DATA
DIMENSIONS (mm inch)
Continuous Use rating (ON time) 50%
With neon lamp 25,000 hours (approx. 3 years) Approx. 6 years
With LED indication 50,000 hours (approx. 5.5 years) 100,000 hours (approx. 11 years)
(Coil terminal No.)
Schematic
LED
Protection diode
Schematic
With LED indication LED
With neon lamp Neon lamp
(Coil terminal No.)
Coil terminal No. and polarity (DC type)
Polarity 2 Form C 3 Form C 4 Form C
Terminal
No. (+) 7 10 10
(–) 2 2 1
1. Life curve 2. Max. switching capacity
10
0
100
200
300
400
500
600
700
800
900
1,000
Load current, A
Operations, ×104
125 V AC cosϕ = 1
5
2
5
0
V
A
C
c
o
s
ϕ
=
1
Mechanical life
more than 10,000,000
operations
100 500 1,00010
10
1
0.1
DC inductive
load
(L/R=7ms)
AC inductive load
(cosϕ=0.4)
DC resistive
load
AC resistive load
Contact voltage, V
Contact current, A
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e
7
.276
51
2.008
.197.315 .197
585
44
1.732
0.5
.020
25
15
.984
.591
.031
8
7
63
54
15.26
5.26 5.26
.207 .207
10
.394
9.5
.374
7.5
.29536
1.417
5.8
.228
5.3
.209
5.26
.207
.207
2
.031
0.8 0.8
0.8
0.8
.031
.031
Compatible with tab terminal
#205 series receptacle.
Plug-in type (2 Form C) External dimensions Schematic (Bottom view)
8
7
6
5
1
2
3
4
CAD Data
Dimension:
Less than 2mm .079inch:
Min. 2mm .079inch less than 9mm .354inch:
Min. 9mm .354inch less than 20mm .787inch:
Min. 20mm .787inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
ASCTB81E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
HP
0.5
.020
44
1.732
3
.118
7
.276
.197
5
38
1.496
36
1.417
36
1.417
38
1.496
11 11
.433 .433
8.5
.335
.217
5.5
.226
5.75
.187 .187
.098
.098 2.5
2.5
7.65
.301
4.1
.161
0.5.020
0.5
.020
.020
0.5
0.5.020
2.079
2.079
.187 4.75 4.754.75
.197.315 .197
585
Compatible with tab terminal
#187 series receptacle.
Plug-in type (3 Form C) External dimensions Schematic (Bottom view)
10
11
9
8
3
6
7
1
2
4
5
CAD Data
Dimension:
Less than 2mm .079inch:
Min. 2mm .079inch less than 9mm .354inch:
Min. 9mm .354inch less than 20mm .787inch:
Min. 20mm .787inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
0.5
.020
44
7
.276
51
1.732
2.008
36
1.417
10
10 .394
.394
25
.984
5.26
7 9 5 4
312148
5.26 5.26 5.26
.207 .207 .207 .207
50
1.969
40
1.575
10
.394
.031 .031 .031.031 0.8 0.8 0.80.8
915 11
25.26 9.5
.374
7.5
.295
5.8
.228
5.3
.209
5.26
.207
.207
0.8
0.8
.031
.031
1
10
Compatible with tab terminal
#205 series receptacle.
Plug-in type (4 Form C) External dimensions Schematic (Bottom view)
915
10
8
7
12
5
11 2
1
14
6
3
4
CAD Data
Dimension:
Less than 2mm .079inch:
Min. 2mm .079inch less than 9mm .354inch:
Min. 9mm .354inch less than 20mm .787inch:
Min. 20mm .787inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
ASCTB81E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
HP
SAFETY STANDARDS
For Cautions for Use.
UL/C-UL (Recognized) CSA (Certified)
File No. Contact rating File No. Contact rating
E43028 10A 250V AC, 1/3HP 125, 250V AC, 10A 30V DC LR26550 etc. 10A 250V AC, 1/3HP 125, 250V AC, 10A 30V DC
.110
2.8
46.8
1.843
24.7
.972
7
.276 5.5
.217
35.7
1.406
15
.591
.031 .031
0.8 0.8
58
2.283
45.5
1.791
9.5
.374
7.5
.295
5.3
.209
0.8
2.25R .089R
5.26
.207 5.26
.207
4.5
.177 10
.394
5.26
5.26
.207
.207
0.8
.031
.031 5.8
.228
Compatible with tab terminal
#205 series receptacle.
TM type
(2 Form C) External dimensions
Schematic (Bottom view)
8
7
6
5
1
2
3
4
Mounting hole diagram
Tolerance: ±0.1 ±.004
(Pitch for side-by-side mounting)
Relay space
(Area shown by the
broken line)
2-M.157 screw hole
or 2-.177 dia. hole
2-M4 screw hole
or 2-4.5 dia. hole
45.5
1.791
2
.079
30
1.181
Installed relay
Nut Panel (chassis)
Spring washer
2-M.157
2-M4 screw
35.7
1.406
52.3
2.059
Dimension:
Less than 2mm .079inch:
Min. 2mm .079inch
less than 9mm .354inch:
Min. 9mm .354inch
less than 20mm .787inch:
Min. 20mm .787inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
CAD Data
.276
7
.118
3
5
.197
20.5
.807
.433
11
38
1.496
16
.630
4.2
.165
73.5
2.894
60
2.362
44
1.732
2.1R
.083R
16
.630
.165
4.2
.083R
2.1R
36
1.417
36
1.417
38
1.496
11 11
.433 .433
8.5
.335
.217
5.5
.226
5.75
.187 .187 .187
4.75 4.75 4.75
2.5
.098
2.5
.098
7.65
.301
4.1
.161
0.5
.020
0.5
.020
0.5 .020
0.5 .020
2.079
2
.079
Compatible with tab terminal
#187 series receptacle.
Direct mounting type
(3 Form C) External dimensions
Schematic (Bottom view)
10
11
9
8
3
6
7
1
2
4
5
Mounting hole diagram
Tolerance: ±0.1 ±.004
(Pitch for side-by-side mounting)
40
1.575
60
2.362
2
.079
2-M.157 screw hole
(or 2-.165 dia. hole)
2-M4 screw hole
(or 2-4.2 dia. hole)
Relay space
(Area shown by the
broken line)
Installed relay
38
1.496
16
.630
.197
5
7
.276
.807
20.5
.433
11
73.5
2.894
2.362
60
44
1.732
2-M.157
2-M4 screw Spring washer
Panel
(chassis)
Nut
36
1.417
Dimension:
Less than 2mm .079inch:
Min. 2mm .079inch
less than 9mm .354inch:
Min. 9mm .354inch
less than 20mm .787inch:
Min. 20mm .787inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
CAD Data
ASCTB81E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e