Stancor Auto and Isolation Transformers, Adapter Plugs and Energy Limiting Transformers Visit StancorOs Website at www.stancor.com Auto/Isolation Transformers Features c Three Conductor Line Cord and Receptacle N Some Items Available with Leadwires c GIS and GISD Series Have Electrostatic Shields Connected to Case, Core and to Third Conductor of Cord and Receptacle c El Laminations c Heavy Duty Welded Plate Ensures Mounting Stability Applications c Computer Protection c Dental Chairs c Electrical Appliances c Lab Test Equipment c Incubator Ovens c LED Signs c Office Copiers and Printers Auto transformers have one winding that is tapped to achieve specific output voltage. They provide no electrical isolation in a circuit. Auto transformers are typically smaller than their isolation equivalent. Isolation transformers have two separate windings with an electrostatic shield between them to provide complete electrical isolation from the source. Auto/isolation transformers can be used in most countries by using an input adapter plug, see International Adapter Plugs section below for StancorOs high quality line. Specifications. Input Cord Length: 51/2' min. Output Cord Length: 8" min. Input Voltages: 115/230 VAC. Operating Temperature: 40 to 105C. Output Voltage: 115/230 VAC. Power Range: 0.6-1500 VA. Auto Transformers Stock No. Mfr.Os Type Style Voltage Step Input Voltage Output Voltage 928-4872 928-0300 928-4873 928-4874 928-0302 928-4875 928-0303 928-0304 928-4876 928-0306 928-0307 928-0308 928-0309 928-6100 928-4877 928-4879 P-8620* GSD-75 P-8630 P-8631 GSD-150 P-8632 GSD-250 GSD-300 P-8634 GSD-500 GSD-750 GSD-1000 GSD-1500 P-8638 P-8639 P-8689 A C C C C C C C C C C C C C C C Down Down Down Down Down Down Down Down Down Down Down Down Down Up Up Up 230 230 230 230 230 230 230 230 230 230 230 230 230 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 230 230 230 A A A C A C C C C C C C C C C Straight Straight Straight Straight Straight Straight Straight Straight Straight Straight Down Down Down Down Down 115 115 115 115 115/230 115 115 115 115 115 230 230 230 230 230 115 115 115 115/230a 115 115 115 115 115 115 115 115 115 115 115 Case Dimensions N In. Mounting N In. EACH Amps VA Capacitance RMS Test Voltage H W D MW MD Weight (Lbs.) 1-49 50-99 0.430 0.650 0.740 1.100 1.300 1.740 2.200 2.600 3.500 4.300 6.500 8.700 13.000 0.540 1.300 4.350 50.00 75.00 85.00 125.00 150.00 200.00 250.00 300.00 400.00 500.00 750.00 1000.00 1500.00 125.00 300.00 1000.00 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2.31 3.13 3.13 3.13 3.88 3.88 3.88 3.88 3.88 4.63 4.63 4.63 5.38 3.13 3.88 4.63 3.69 2.50 2.50 2.50 3.13 3.13 3.13 3.13 3.13 3.81 3.81 3.81 4.44 2.50 3.13 3.75 1.88 2.88 2.88 3.00 3.25 3.25 3.63 3.63 4.25 4.44 5.38 6.06 6.00 3.00 3.88 6.13 3.13 2.00 2.00 2.00 2.50 2.50 2.50 2.50 2.50 3.00 3.00 3.00 3.50 2.00 2.50 3.00 N 1.75 1.75 2.06 2.22 2.22 2.22 2.22 2.72 3.19 3.94 4.69 4.00 2.06 2.22 4.69 1.50 3.00 2.50 3.00 4.40 4.20 5.80 5.80 7.00 10.60 14.40 17.00 20.00 3.00 5.20 17.00 10.57 47.37 34.44 34.03 50.54 40.87 60.81 80.34 47.38 67.10 81.11 104.61 155.67 35.46 42.75 76.78 9.85 44.15 32.10 31.72 47.11 38.10 56.69 74.89 44.17 61.51 74.35 97.52 145.11 33.05 39.85 71.58 0.005 0.130 0.300 1.300 0.430 0.870 1.300 2.170 4.350 8.700 0.870 1.300 2.170 4.350 8.700 0.60 15.00 35.00 150.00 50.00 100.00 150.00 250.00 500.00 1000.00 100.00 150.00 250.00 500.00 1000.00 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1.25 2.00 2.38 3.88 2.38 3.50 3.88 4.69 4.69 5.38 3.50 3.88 4.69 4.69 5.38 2.13 3.25 3.75 3.13 3.75 2.81 3.13 3.75 3.75 4.38 2.81 3.13 3.75 3.75 4.38 1.25 1.88 2.00 4.00 2.31 3.56 4.19 4.38 6.00 8.13 3.63 4.19 4.38 6.00 8.13 1.75 2.81 3.13 2.50 3.13 2.25 2.50 3.00 3.00 3.50 2.25 2.50 3.00 3.00 3.50 N N N 2.72 N 2.28 2.72 3.19 4.69 6.50 2.28 2.72 3.19 4.69 6.50 0.25 1.00 1.70 6.20 1.80 4.50 7.00 9.00 16.00 31.00 4.50 7.00 9.00 16.00 31.00 15.54 15.37 19.43 35.83 25.31 63.05 58.78 85.16 98.74 193.60 63.95 70.02 70.01 98.55 200.30 14.49 14.33 18.11 33.40 23.60 58.78 54.79 79.39 92.04 180.47 59.61 65.28 65.26 91.87 186.72 Isolation Transformers 928-6413 928-3033 928-3034 928-4880 928-3037 928-0325 928-0326 928-0327 928-0328 928-0329 928-0350 928-0351 928-0352 928-0353 928-0354 P-6413* P-6411* P-6412* P-8622 P-6406* GIS-100 GIS-150 GIS-250 GIS-500 GIS-1000 GISD-100 GISD-150 GISD-250 GISD-500 GISD-1000 *Has leadwires. Has electrostatic shield on separate leadwire (not grounded). aSecondary is two separate 115 V windings. Primary is two separate 115 V windings. International Adapter Plugs Grounding adapters, ideal for use on electrical/electronic equipment on the CEE-7 SCHUKO outlet configuration. The use of these adapters reduces the need for expensive and difficult-to-obtain foreign type power cords and cord sets, as they provide a fast, easy means of connecting equipment to European outlets. European to American N Fig. B American to European N Fig. A European to United Kingdom N Fig. C Allows interface from NEMA 6-15P plugs to CEE-7 SCHUKO grounding outlets. 928-9951. ADT-30100. 1-49 ................................................................................................................................ EACH 10.36 Allows interface from CEE-7 SCHUKO plugs to NEMA 6-15R grounding outlets. 928-9952. ADT-30120. 1-49 ................................................................................................................................. EACH 19.55 Allows interface from CEE-7 SCHUKO plugs to U.K. 13 A, 250 V receptacles. 928-9953. ADT-30140. 1-49 ................................................................................................................................. EACH 18.08 Energy Limiting Transformers 17 Features c Heavy Duty Welded Mounting Plate Provides Mounting Stability c Rigid 1/4" Q.C. Terminals Provide Ease of Installation c Rated for Continuous Duty c Windings and Internal Connections Enclosed with Insulating Plastic Cover for Safety c Non-Concentric Windings Reduce Size and Cost and Improve Manufacturability Applications c Commercial Dryers c Deep Fryers c Greenhouse Controls c Home Environmental Systems c Security Systems c Video Games c Automatic Doors c Solar Heating Units Meet UL safety specifications. Split bobbin winding reduces capacitive coupling and eliminates need for electrostatic shield. Broad range of input voltage combinations cover most HVAC applications. 40AV power rating eliminates need for multiple parts to cover lower power requirements. All primaries 50/60 Hz. Stock No. Mfr.Os Type Input Voltage Output Voltage Output Current VA Mounting 928-0001 928-0002 928-0003 928-0004 928-0005 592-9012 592-9013 592-9016 592-9017 592-9018 120 240 120/240 208/240 120/208/240 24 24 24 24 24 1.67 1.67 1.67 1.67 1.67 40 40 40 40 40 Horizontal Horizontal Horizontal Horizontal Horizontal Secondary Terminal 1/ 4 1/ 4 QC QC 1/ 4 QC 1/ 4 QC 1/ 4 QC Primary Terminal 1/ 4 1/ 4 QC QC 1/ 4 QC 1/ 4 QC 1/ 4 QC Dim. N In. EACH H W D MW Weight (Lbs.) Agency Certification* 1-49 50-99 2.25 2.25 2.25 2.25 2.25 3.69 3.69 3.69 3.69 3.69 2.25 2.25 2.25 2.25 2.25 3.13 3.13 3.13 3.13 3.13 1.5 1.5 1.5 1.5 1.5 UL Class 2/CSA UL Class 2/CSA UL Class 2/CSA UL Class 2/CSA UL Class 2/CSA 10.05 45.00 10.53 10.53 11.07 9.37 41.00 9.82 9.82 10.32 *Agency Certification Note: UL Recognized (File E-109254), UL Class 2, CSA Certified (File LR 67888). 1050 b ALLIED For Local Personalized Service Call 1-800-433-5700