NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Features * * * * CAS Latency and Frequency CAS Latency 3 2.5 Maximum Operating Frequency (MHz) DDR400B (-5T) 200 166 * * * * * * * * * * Double data rate architecture: two data transfers per clock cycle * Bidirectional data strobe (DQS) is transmitted and received with data, to be used in capturing data at the receiver * DQS is edge-aligned with data for reads and is centeraligned with data for writes * Differential clock inputs (CK and CK) Four internal banks for concurrent operation Data mask (DM) for write data DLL aligns DQ and DQS transitions with CK transitions Commands entered on each positive CK edge; data and data mask referenced to both edges of DQS Burst lengths: 2, 4, or 8 CAS Latency: 2.5, 3 Auto Precharge option for each burst access Auto Refresh and Self Refresh Modes 7.8s Maximum Average Periodic Refresh Interval SSTL_2 compatible I/O interface VDDQ = 2.6V 0.1V VDD = 2.6V 0.1V Lead-free and Halogen-free product available Description The 256Mb DDR SDRAM is a high-speed CMOS, dynamic random-access memory containing 268,435,456 bits. It is internally configured as a quad-bank DRAM. tion may be enabled to provide a self-timed row precharge that is initiated at the end of the burst access. As with standard SDRAMs, the pipelined, multibank architecture of DDR SDRAMs allows for concurrent operation, thereby providing high effective bandwidth by hiding row precharge and activation time. The 256Mb DDR SDRAM uses a double-data-rate architecture to achieve high-speed operation. The double data rate architecture is essentially a 2n prefetch architecture with an interface designed to transfer two data words per clock cycle at the I/O pins. A single read or write access for the 256Mb DDR SDRAM effectively consists of a single 2n-bit wide, one clock cycle data transfer at the internal DRAM core and two corresponding n-bit wide, one-half-clock-cycle data transfers at the I/O pins. An auto refresh mode is provided along with a power-saving Power Down mode. All inputs are compatible with the JEDEC Standard for SSTL_2. All outputs are SSTL_2, Class II compatible. The functionality described and the timing specifications included in this data sheet are for the DLL Enabled mode of operation. A bidirectional data strobe (DQS) is transmitted externally, along with data, for use in data capture at the receiver. DQS is a strobe transmitted by the DDR SDRAM during Reads and by the memory controller during Writes. DQS is edgealigned with data for Reads and center-aligned with data for Writes. The 256Mb DDR SDRAM operates from a differential clock (CK and CK; the crossing of CK going high and CK going LOW is referred to as the positive edge of CK). Commands (address and control signals) are registered at every positive edge of CK. Input data is registered on both edges of DQS, and output data is referenced to both edges of DQS, as well as to both edges of CK. Read and write accesses to the DDR SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an Active command, which is then followed by a Read or Write command. The address bits registered coincident with the Active command are used to select the bank and row to be accessed. The address bits registered coincident with the Read or Write command are used to select the bank and the starting column location for the burst access. The DDR SDRAM provides for programmable Read or Write burst lengths of 2, 4, or 8 locations. An Auto Precharge func- REV 1.3 06/2003 1 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Pin Configuration - 400mil TSOP II (x4 / x8 / x16) VD D VDD VDD 1 66 V SS VSS VSS NC DQ0 DQ0 2 65 DQ15 DQ7 NC VDDQ VDDQ VDDQ 3 64 V SSQ VSSQ VSSQ NC NC DQ1 4 63 DQ14 NC NC DQ0 DQ1 DQ13 DQ6 DQ3 VSSQ V SSQ VSSQ 6 61 V DDQ VDDQ VDDQ NC NC DQ3 7 60 DQ12 NC NC NC DQ2 DQ4 8 59 DQ11 DQ5 NC VDDQ VDDQ VDDQ 9 58 V SSQ VSSQ VSSQ NC NC DQ5 10 57 DQ10 NC NC DQ1 DQ3 DQ6 11 56 DQ9 DQ4 DQ2 VSSQ VSSQ VSSQ 12 55 V DDQ VDDQ VDDQ NC NC DQ7 13 54 DQ8 NC NC NC NC NC 14 53 NC NC NC VDDQ VDDQ VDDQ 15 52 V SSQ VSSQ VSSQ NC NC LDQS 16 51 UDQS DQS DQS NC NC NC 17 50 NC NC NC VD D VDD VDD 18 49 V REF VREF VREF NU NU NU 19 48 V SS VSS VSS NC NC LDM* 20 47 UDM* DM* DM* WE CAS WE WE 21 46 CK CAS CAS 22 45 CK CK CK CK CK RAS RAS RAS 23 44 CKE CKE CKE CS CS CS 24 43 NC NC NC NC NC NC 25 42 A12 A12 A12 BA0 BA0 BA1 26 41 A11 A11 A11 BA1 BA0 BA1 27 40 A9 A9 A10/AP A10/AP A10/AP 28 39 A9 A8 A8 A8 A0 A0 A0 29 38 A7 A7 A7 A1 A1 A1 30 37 A6 A6 A6 A2 A2 A2 31 36 A5 A5 A5 A3 A3 A3 32 35 A4 A4 A4 VDD VD D VDD 33 34 V SS V SS V SS DQ2 5 62 66-pin Plastic TSOP-II 400mil 16Mb x 16 32Mb x 8 64Mb x 4 Column Address Table Organization Column Address 64Mb x 4 A0-A9, A11 32Mb x 8 A0-A9 16Mb x 16 A0-A8 *DM is internally loaded to match DQ and DQS identically . REV 1.3 06/2003 2 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Pin Configuration - 60 balls 0.8mmx1.0mm Pitch CSP Package See the balls through the package. 64 X 4 1 2 3 7 8 9 VSSQ NC VSS A VDD NC VDDQ NC VDDQ DQ3 B DQ0 VSSQ NC NC VSSQ NC C NC VDDQ NC NC VDDQ DQ2 D DQ1 VSSQ NC NC VSSQ DQS E QFC VDDQ NC VREF VSS DQM F NC VDD NC CLK CLK G WE CAS A12 CKE H RAS CS A11 A9 J BA1 BA0 A8 A7 K A0 A10/AP A6 A5 L A2 A1 A4 VSS M VDD A3 7 8 9 32 X 8 REV 1.3 06/2003 1 2 3 VSSQ DQ7 VSS A VDD DQ0 VDDQ NC VDDQ DQ6 B DQ1 VSSQ NC NC VSSQ DQ5 C DQ2 VDDQ NC NC VDDQ DQ4 D DQ3 VSSQ NC NC VSSQ DQS E QFC VDDQ NC VREF VSS DQM F NC VDD NC CLK CLK G WE CAS A12 CKE H RAS CS A11 A9 J BA1 BA0 A8 A7 K A0 A10/AP A6 A5 L A2 A1 A4 VSS M VDD A3 3 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Pin Configuration - 60 balls 0.8mmx1.0mm Pitch CSP Package See the balls through the package. 16 X 16 REV 1.3 06/2003 1 2 3 7 8 9 VSSQ DQ15 VSS A VDD DQ0 VDDQ DQ14 VDDQ DQ13 B DQ2 VSSQ DQ1 DQ12 VSSQ DQ11 C DQ4 VDDQ DQ3 DQ10 VDDQ DQ9 D DQ6 VSSQ DQ5 DQ8 VSSQ DQS E LDQS VDDQ DQ7 VREF VSS DQM F LDW VDD NC CLK CLK G WE CAS A12 CKE H RAS CS A11 A9 J BA1 BA0 A8 A7 K A0 A10/AP A6 A5 L A2 A1 A4 VSS M VDD A3 4 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Input/Output Functional Description Symbol Type Function Input Clock: CK and CK are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CK and negative edge of CK. Output (read) data is referenced to the crossings of CK and CK (both directions of crossing). Input Clock Enable: CKE HIGH activates, and CKE Low deactivates, internal clock signals and device input buffers and output drivers. Taking CKE Low provides Precharge Power Down and Self Refresh operation (all banks idle), or Active Power Down (row Active in any bank). CKE is synchronous for power down entry and exit, and for self refresh entry. CKE is asynchronous for self refresh exit. CKE must be maintained high throughout read and write accesses. Input buffers, excluding CK, CK and CKE are disabled during Power Down. Input buffers, excluding CKE, are disabled during self refresh. The standard pinout includes one CKE pin. Optional pinouts might include CKE1 on a different pin, in addition to CKE0, to facilitate independent power down control of stacked devices. CS, CS0, CS1 Input Chip Select: All commands are masked when CS is registered high. CS provides for external bank selection on systems with multiple banks. CS is considered part of the command code. The standard pinout includes one CS pin. Optional pinouts might include CS1 on a different pin, in addition to CS0, to allow upper or lower deck selection on stacked devices. RAS, CAS , WE Input Command Inputs: RAS, CAS and WE (along with CS) define the command being entered. DM Input Input Data Mask: DM is an input mask signal for write data. Input data is masked when DM is sampled high coincident with that input data during a Write access. DM is sampled on both edges of DQS. Although DM pins are input only, the DM loading matches the DQ and DQS loading. During a Read, DM can be driven high, low, or floated. BA0, BA1 Input Bank Address Inputs: BA0 and BA1 define to which bank an Active, Read, Write or Precharge command is being applied. BA0 and BA1 also determines if the mode register or extended mode register is to be accessed during a MRS or EMRS cycle. A0 - A12 Input Address Inputs: Provide the row address for Active commands, and the column address and Auto Precharge bit for Read/Write commands, to select one location out of the memory array in the respective bank. A10 is sampled during a Precharge command to determine whether the Precharge applies to one bank (A10 low) or all banks (A10 high). If only one bank is to be precharged, the bank is selected by BA0, BA1. The address inputs also provide the op-code during a Mode Register Set command. DQ Input/Output Data Input/Output: Data bus. DQS, LDQS, UDQS Input/Output Data Strobe: Output with read data, input with write data. Edge-aligned with read data, centered in write data. Used to capture write data. For the x16, LDQS corresponds to the data on DQ0DQ7; UDQS corresponds to the data on DQ8-DQ15 CK, CK CKE, CKE0, CKE1 NC No Connect: No internal electrical connection is present. NU Electrical connection is present. Should not be connected at second level of assembly. V DDQ Supply DQ Power Supply: 2.6V 0.1V. V SSQ Supply DQ Ground V DD Supply Power Supply: 2.6V 0.1V. V SS Supply Ground V REF Supply SSTL_2 reference voltage: (V DDQ / 2) 1%. REV 1.3 06/2003 5 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Ordering Information Speed Org. Part Number Clock (MHz) CL-tRCD -tRP 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS64M4BF-5T 60ball BGA 0.8mmx1.0mm Pitch 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS32M8BT-5T 66 pin TSOP-II 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS32M8BF-5T 60ball BGA 0.8mmx1.0mm Pitch 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS16M16BT-5T 66 pin TSOP-II 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS16M16BF-5T 60ball BGA 0.8mmx1.0mm Pitch 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS64M4BS-5T1 66 pin TSOP-II 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS64M4BG-5T 1 60ball BGA 0.8mmx1.0mm Pitch 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS32M8BS-5T1 66 pin TSOP-II 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS32M8BG-5T 1 60ball BGA 0.8mmx1.0mm Pitch 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS16M16BS-5T 1 66 pin TSOP-II 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B NT5DS16M16BG-5T 1 60ball BGA 0.8mmx1.0mm Pitch 200 3-3-3/3-4-4 166 2.5-3-3 DDR400B 16M x 16 16M x 16 CL-tRCD-tRP 66 pin TSOP-II 32M x 8 32M x 8 Comments Clock (MHz) NT5DS64M4BT-5T 64M x 4 64M x 4 Package Note: 1. Lead-free and Halogen-free product 2. At the present time, there are no plans to support DDR SDRAMs with the QFC function. All reference to QFC are for information only REV 1.3 06/2003 6 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Control Logic 2 Bank3 CK, CK 2 8192 4 8 8 1024 (x8) Write FIFO & Drivers 1 DQS Generator clk clk out in CK, CK COL0 DQS Input Register Mask 1 1 2 8 10 Column-Address Counter/Latch 4 COL0 I/O Gating DM Mask Logic Column Decoder 11 Drivers 8 Sense Amplifiers Data 4 MUX Bank0 Memory Array (8192 x 1024 x 8) Read Latch 8192 1 1 4 4 4 4 DQ0-DQ3, DM DQS 1 Receivers 15 Refresh Counter 13 A0-A12, BA0, BA1 13 Address Register 15 13 Bank2 DLL Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (64Mb x 4) 4 Data COL0 1 1 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: DM is a unidirectional signal (input only), but is internally loaded to match the load of the bidirectional DQ and DQS signals. REV 1.3 06/2003 7 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Control Logic 2 Bank2 Bank3 CK, CK DLL 2 8192 8 8 8 16 16 512 (x16) Write FIFO & Drivers Input Register 1 Mask 1 1 1 8 8 8 clk clk out in Data 8 2 16 9 Column-Address Counter/Latch 1 DQS Generator COL0 I/O Gating DM Mask Logic Column Decoder 10 Drivers 16 Sense Amplifiers Data MUX Bank0 Memory Array (8192 x 512 x 16) Read Latch 8192 CK, CK COL0 DQS DQ0-DQ7, DM DQS 1 Receivers 15 Address Register A0-A12, BA0, BA1 13 Refresh Counter 13 15 13 Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (32Mb x 8) 8 COL0 1 1 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: DM is a unidirectional signal (input only), but is internally loaded to match the load of the bidirectional DQ and DQS signals. REV 1.3 06/2003 8 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Control Logic 2 Bank2 Bank3 CK, CK DLL 2 8192 16 16 16 32 32 256 (x32) Write FIFO & Drivers Input Register 1 Mask 1 1 1 16 16 16 clk clk out in Data 16 2 32 8 Column-Address Counter/Latch 1 DQS Generator COL0 I/O Gating DM Mask Logic Column Decoder 9 Drivers 32 Sense Amplifiers Data MUX Bank0 Memory Array (8192 x 256 x 32) Read Latch 8192 CK, CK COL0 DQS DQ0-DQ15, LDM, UDM LDQS,UDQS 1 Receivers 15 Address Register A0-A12, BA0, BA1 13 Refresh Counter 13 15 13 Bank Control Logic Mode Registers Bank0 Row-Address Latch & Decoder Bank1 Row-Address MUX CKE CK CK CS WE CAS RAS Command Decode Block Diagram (16Mb x 16) 16 COL0 1 1 Note: This Functional Block Diagram is intended to facilitate user understanding of the operation of the device; it does not represent an actual circuit implementation. Note: DM is a unidirectional signal (input only), but is internally loaded to match the load of the bidirectional DQ and DQS signals. REV 1.3 06/2003 9 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Functional Description The 256Mb DDR SDRAM is a high-speed CMOS, dynamic random-access memory containing 268, 435, 456 bits. The 256Mb DDR SDRAM is internally configured as a quad-bank DRAM. The 256Mb DDR SDRAM uses a double-data-rate architecture to achieve high-speed operation. The double-data-rate architecture is essentially a 2n prefetch architecture, with an interface designed to transfer two data words per clock cycle at the I/O pins. A single read or write access for the 256Mb DDR SDRAM consists of a single 2n-bit wide, one clock cycle data transfer at the internal DRAM core and two corresponding n-bit wide, one-half clock cycle data transfers at the I/O pins. Read and write accesses to the DDR SDRAM are burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Accesses begin with the registration of an Active command, which is then followed by a Read or Write command. The address bits registered coincident with the Active command are used to select the bank and row to be accessed (BA0, BA1 select the bank; A0-A12 select the row). The address bits registered coincident with the Read or Write command are used to select the starting column location for the burst access. Prior to normal operation, the DDR SDRAM must be initialized. The following sections provide detailed information covering device initialization, register definition, command descriptions and device operation. Initialization Only one of the following two conditions must be met. * No power sequencing is specified during power up or power down given the following criteria: VDD and VDDQ are driven from a single power converter output VTT meets the specification A minimum resistance of 42 ohms limits the input current from the VTT supply into any pin and VREF tracks VDDQ /2 or * The following relationships must be followed: VDDQ is driven after or with VDD such that V DDQ < V DD + 0.3V VTT is driven after or with VDDQ such that VTT < V DDQ + 0.3V VREF is driven after or with V DDQ such that VREF < VDDQ + 0.3V The DQ and DQS outputs are in the High-Z state, where they remain until driven in normal operation (by a read access). After all power supply and reference voltages are stable, and the clock is stable, the DDR SDRAM requires a 200s delay prior to applying an executable command. Once the 200s delay has been satisfied, a Deselect or NOP command should be applied, and CKE must be brought HIGH. Following the NOP command, a Precharge ALL command must be applied. Next a Mode Register Set command must be issued for the Extended Mode Register, to enable the DLL, then a Mode Register Set command must be issued for the Mode Register, to reset the DLL, and to program the operating parameters. 200 clock cycles are required between the DLL reset and any read command. A Precharge ALL command should be applied, placing the device in the "all banks idle" state Once in the idle state, two auto refresh cycles must be performed. Additionally, a Mode Register Set command for the Mode Register, with the reset DLL bit deactivated (i.e. to program operating parameters without resetting the DLL) must be performed. Following these cycles, the DDR SDRAM is ready for normal operation. DDR SDRAM's may be reinitialized at any time during normal operation by asserting a valid MRS command to either the base or extended mode registers without affecting the contents of the memory array. The contents of either the mode register or extended mode register can be modified at any valid time during device operation without affecting the state of the internal address refresh counters used for device refresh. REV 1.3 06/2003 10 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Register Definition Mode Register The Mode Register is used to define the specific mode of operation of the DDR SDRAM. This definition includes the selection of a burst length, a burst type, a CAS latency, and an operating mode. The Mode Register is programmed via the Mode Register Set command (with BA0 = 0 and BA1 = 0) and retains the stored information until it is programmed again or the device loses power (except for bit A8, which is self-clearing). Mode Register bits A0-A2 specify the burst length, A3 specifies the type of burst (sequential or interleaved), A4-A6 specify the CAS latency, and A7-A12 specify the operating mode. The Mode Register must be loaded when all banks are idle, and the controller must wait the specified time before initiating the subsequent operation. Violating either of these requirements results in unspecified operation. Burst Length Read and write accesses to the DDR SDRAM are burst oriented, with the burst length being programmable. The burst length determines the maximum number of column locations that can be accessed for a given Read or Write command. Burst lengths of 2, 4, or 8 locations are available for both the sequential and the interleaved burst types. Reserved states should not be used, as unknown operation or incompatibility with future versions may result. When a Read or Write command is issued, a block of columns equal to the burst length is effectively selected. All accesses for that burst take place within this block, meaning that the burst wraps within the block if a boundary is reached. The block is uniquely selected by A1-Ai when the burst length is set to two, by A2 -Ai when the burst length is set to four and by A3 -Ai when the burst length is set to eight (where Ai is the most significant column address bit for a given configuration). The remaining (least significant) address bit(s) is (are) used to select the starting location within the block. The programmed burst length applies to both Read and Write bursts. REV 1.3 06/2003 11 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Mode Register Operation BA1 BA0 0* 0* A12 - A9 A8 A12 A11 A10 A9 A8 A7 A6 - A0 Operating Mode 0 0 0 Valid Normal operation Do not reset DLL 0 1 0 Valid Normal operation in DLL Reset 0 0 1 - - - A5 A4 CAS Latency Operating Mode A7 A6 A3 A2 BT A1 Burst Length A3 Burst Type 0 Sequential 1 Interleave A0 Address Bus Mode Register Vendor-Specific Test Mode VS** Reserved CAS Latency Burst Length A6 A5 A4 Latency A2 A1 A0 Burst Length 0 0 0 Reserved 0 0 0 Reserved 0 0 1 Reserved 0 0 1 2 0 1 0 2 0 1 0 4 0 1 1 3 0 1 1 8 1 0 0 Reserved 1 0 0 Reserved 1 0 1 1.5 (Option) 1 0 1 Reserved 1 1 0 2.5 1 1 0 Reserved 1 1 1 Reserved 1 1 1 Reserved VS ** Vendor Specific * BA0 and BA1 must be 0, 0 to select the Mode Register (vs. the Extended Mode Register). REV 1.3 06/2003 12 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Burst Definition Starting Column Address Order of Accesses Within a Burst Burst Length A2 A1 A0 Type = Sequential Type = Interleaved 0 0-1 0-1 1 1-0 1-0 0 0 0-1-2-3 0-1-2-3 0 1 1-2-3-0 1-0-3-2 1 0 2-3-0-1 2-3-0-1 1 1 3-0-1-2 3-2-1-0 0 0 0 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7 0 0 1 1-2-3-4-5-6-7-0 1-0-3-2-5-4-7-6 0 1 0 2-3-4-5-6-7-0-1 2-3-0-1-6-7-4-5 0 1 1 3-4-5-6-7-0-1-2 3-2-1-0-7-6-5-4 1 0 0 4-5-6-7-0-1-2-3 4-5-6-7-0-1-2-3 1 0 1 5-6-7-0-1-2-3-4 5-4-7-6-1-0-3-2 1 1 0 6-7-0-1-2-3-4-5 6-7-4-5-2-3-0-1 1 1 1 7-0-1-2-3-4-5-6 7-6-5-4-3-2-1-0 2 4 8 Notes: 1. For a burst length of two, A1-A i selects the two-data-element block; A0 selects the first access within the block. 2. For a burst length of four, A2-A i selects the four-data-element block; A0-A1 selects the first access within the block. 3. For a burst length of eight, A3-A i selects the eight-data- element block; A0-A2 selects the first access within the block. 4. Whenever a boundary of the block is reached within a given sequence above, the following access wraps within the block. Burst Type Accesses within a given burst may be programmed to be either sequential or interleaved; this is referred to as the burst type and is selected via bit A3. The ordering of accesses within a burst is determined by the burst length, the burst type and the starting column address, as shown in Burst Definition on page 13. Read Latency The Read latency, or CAS latency, is the delay, in clock cycles, between the registration of a Read command and the availability of the first burst of output data. The latency can be programmed 2.5 or 3 clocks. If a Read command is registered at clock edge n, and the latency is m clocks, the data is available nominally coincident with clock edge n + m. Reserved states should not be used as unknown operation or incompatibility with future versions may result. REV 1.3 06/2003 13 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Operating Mode The normal operating mode is selected by issuing a Mode Register Set Command with bits A7-A12 to zero, and bits A0-A6 set to the desired values. A DLL reset is initiated by issuing a Mode Register Set command with bits A7 and A9-A12 each set to zero, bit A8 set to one, and bits A0-A6 set to the desired values. A Mode Register Set command issued to reset the DLL should always be followed by a Mode Register Set command to select normal operating mode. All other combinations of values for A7-A12 are reserved for future use and/or test modes. Test modes and reserved states should not be used as unknown operation or incompatibility with future versions may result. CAS Latencies CAS Latency = 3, BL = 4 CK CK Command Read NOP NOP NOP NOP NOP CL=3 DQS DQ CAS Latency = 2.5, BL = 4 CK CK Command Read NOP NOP NOP NOP NOP CL=2.5 DQS DQ Shown with nominal t AC, tDQSCK , and tDQSQ . REV 1.3 06/2003 Don't Care 14 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Extended Mode Register The Extended Mode Register controls functions beyond those controlled by the Mode Register; these additional functions include DLL enable/disable, bit A0; output drive strength selection, bit A1; and QFC output enable/disable, bit A2 (NTC optional). These functions are controlled via the bit settings shown in the Extended Mode Register Definition. The Extended Mode Register is programmed via the Mode Register Set command (with BA0 = 1 and BA1 = 0) and retains the stored information until it is programmed again or the device loses power. The Extended Mode Register must be loaded when all banks are idle, and the controller must wait the specified time before initiating any subsequent operation. Violating either of these requirements result in unspecified operation. DLL Enable/Disable The DLL must be enabled for normal operation. DLL enable is required during power up initialization, and upon returning to normal operation after having disabled the DLL for the purpose of debug or evaluation. The DLL is automatically disabled when entering self refresh operation and is automatically re-enabled upon exit of self refresh operation. Any time the DLL is enabled, 200 clock cycles must occur to allow time for the internal clock to lock to the externally applied clock before a Read command can be issued. This is the reason for introducing timing parameter tXSRD for DDR SDRAM's (Exit Self Refresh to Read Command). Non- Read commands can be issued 2 clocks after the DLL is enabled via the EMRS command (tMRD ) or 10 clocks after the DLL is enabled via self refresh exit command (t XSNR, Exit Self Refresh to Non-Read Command). Output Drive Strength The normal drive strength for all outputs is specified to be SSTL_2, Class II. QFC Enable/Disable The QFC signal is an optional DRAM output control used to isolate module loads (DIMMs) from the system memory bus by means of external FET switches when the given module (DIMM) is not being accessed. The QFC function is an optional feature for NANYA and is not included on all DDR SDRAM devices. REV 1.3 06/2003 15 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Extended Mode Register Definition BA1 BA0 0* 1* A 12 A 11 A 10 A9 A8 A7 A6 A5 A4 A3 Operating Mode A2 A1 A0 Address Bus QFC DS DLL Extended Mode Register Drive Strength A12 - A3 A2 - A0 Operating Mode 0 Valid Normal Operation - - All other states Reserved A2 QFC 0 Disable 1 Enable (Optional) * BA0 and BA1 must be 1, 0 to select the Extended Mode Register (vs. the base Mode Register) REV 1.3 06/2003 A1 Drive Strength 0 Normal 1 Reserved A0 DLL 0 Enable 1 Disable 16 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Commands Truth Tables 1a and 1b provide a reference of the commands supported by DDR SDRAM devices. A verbal description of each commands follows. Truth Table 1a: Commands Name (Function) CS RAS CAS WE Address MNE Notes Deselect (Nop) H X X X X NOP 1, 9 No Operation (Nop) L H H H X NOP 1, 9 Active (Select Bank And Activate Row) L L H H Bank/Row ACT 1, 3 Read (Select Bank And Column, And Start Read Burst) L H L H Bank/Col Read 1, 4 Write (Select Bank And Column, And Start Write Burst) L H L L Bank/Col Write 1, 4 Burst Terminate L H H L X BST 1, 8 Precharge (Deactivate Row In Bank Or Banks) L L H L Code PRE 1, 5 Auto Refresh Or Self Refresh (Enter Self Refresh Mode) L L L H X AR / SR 1, 6, 7 Mode Register Set L L L L Op-Code MRS 1, 2 1. CKE is high for all commands shown except Self Refresh. 2. BA0, BA1 select either the Base or the Extended Mode Register (BA0 = 0, BA1 = 0 selects Mode Register; BA0 = 1, BA1 = 0 selects Extended Mode Register; other combinations of BA0-BA1 are reserved; A0-A12 provide the op-code to be written to the selected Mode Register.) 3. B A0-BA1 provide bank address and A0-A 12 provide row address. 4. BA0, BA1 provide bank address; A0-Ai provide column address (where i = 9 for x8 and 9, 11 for x4); A10 high enables the Auto Precharge feature (non-persistent), A10 low disables the Auto Precharge feature. 5. A10 LOW: BA0, BA1 determine which bank is precharged. A10 HIGH: all banks are precharged and BA0, BA1 are "Don't Care." 6. This command is auto refresh if CKE is high; Self Refresh if CKE is low. 7. Internal refresh counter controls row and bank addressing; all inputs and I/Os are "Don't Care" except for CKE. 8. Applies only to read bursts with Auto Precharge disabled; this command is undefined (and should not be used) for read bursts with Auto Precharge enabled or for write bursts 9. Deselect and NOP are functionally interchangeable. Truth Table 1b: DM Operation Name (Function) DM DQs Notes Write Enable L Valid 1 Write Inhibit H X 1 1. Used to mask write data; provided coincident with the corresponding data. REV 1.3 06/2003 17 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Deselect The Deselect function prevents new commands from being executed by the DDR SDRAM. The DDR SDRAM is effectively deselected. Operations already in progress are not affected. No Operation (NOP) The No Operation (NOP) command is used to perform a NOP to a DDR SDRAM. This prevents unwanted commands from being registered during idle or wait states. Operations already in progress are not affected. Mode Register Set The mode registers are loaded via inputs A0-A12, BA0 and BA1 while issuing the Mode Register Set Command. See mode register descriptions in the Register Definition section. The Mode Register Set command can only be issued when all banks are idle and no bursts are in progress. A subsequent executable command cannot be issued until t MRD is met. Active The Active command is used to open (or activate) a row in a particular bank for a subsequent access. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A12 selects the row. This row remains active (or open) for accesses until a Precharge (or Read or Write with Auto Precharge) is issued to that bank. A Precharge (or Read or Write with Auto Precharge) command must be issued and completed before opening a different row in the same bank. Read The Read command is used to initiate a burst read access to an active (open) row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 9, j = don't care] for x8; where [i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end of the Read burst; if Auto Precharge is not selected, the row remains open for subsequent accesses. Write The Write command is used to initiate a burst write access to an active (open) row. The value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 9, j = don't care] for x8; where [i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end of the Write burst; if Auto Precharge is not selected, the row remains open for subsequent accesses. Input data appearing on the DQs is written to the memory array subject to the DM input logic level appearing coincident with the data. If a given DM signal is registered low, the corresponding data is written to memory; if the DM signal is registered high, the corresponding data inputs are ignored, and a Write is not executed to that byte/column location. Precharge The Precharge command is used to deactivate (close) the open row in a particular bank or the open row(s) in all banks. The bank(s) will be available for a subsequent row access a specified time (tRP ) after the Precharge command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. Otherwise BA0, BA1 are treated as "Don't Care." Once a bank has been precharged, it is in the idle state and must be activated prior to any Read or Write commands being issued to that bank. A precharge command is treated as a NOP if there is no open row in that bank, or if the previously open row is already in the process of precharging. REV 1.3 06/2003 18 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Auto Precharge Auto Precharge is a feature which performs the same individual-bank precharge function described above, but without requiring an explicit command. This is accomplished by using A10 to enable Auto Precharge in conjunction with a specific Read or Write command. A precharge of the bank/row that is addressed with the Read or Write command is automatically performed upon completion of the Read or Write burst. Auto Precharge is non-persistent in that it is either enabled or disabled for each individual Read or Write command. Auto Precharge ensures that the precharge is initiated at the earliest valid stage within a burst. This is determined as if an explicit Precharge command was issued at the earliest possible time without violating t RAS(min). The user must not issue another command to the same bank until the precharge (t RP) is completed. The NTC DDR SDRAM devices supports the optional t RAS lockout feature. This feature allows a Read command with Auto Precharge to be issued to a bank that has been activated (opened) but has not yet satisfied the t RAS(min) specification. The t RAS lockout feature essentially delays the onset of the auto precharge operation until two conditions occur. One, the entire burst length of data has been successfully prefetched from the memory array; and two, tRAS (min) has been satisfied. As a means to specify whether a DDR SDRAM device supports the t RAS lockout feature, a new parameter has been defined, tRAP (RAS Command to Read Command with Auto Precharge or better stated Bank Activate to Read Command with Auto Precharge). For devices that support the tRAS lockout feature, tRAP = t RCD (min). This allows any Read Command (with or without Auto Precharge) to be issued to an open bank once tRCD (min) is satisfied. tRAP Definition CL=3, t CK =10ns CK CK Command NOP ACT NOP RD A NOP NOP DQ (BL=2) DQ0 tRASmin Command NOP ACT NOP RD A NOP NOP DQ (BL=4) Command DQ0 NOP ACT NOP RD A NOP NOP DQ (BL=8) DQ0 NOP NOP ACT NOP NOP ACT NOP NOP NOP ACT NOP DQ1 * tRPmin NOP DQ1 NOP DQ2 tRPmin * NOP DQ1 DQ3 NOP DQ2 tRCDmin tRAPmin * DQ3 * DQ4 DQ5 DQ6 DQ7 tRPmin Indicates Auto Precharge begins here The above timing diagrams show the effects of t RAP for devices that support t RAS lockout. In these cases, the Read with Auto Precharge command (RDA) is issued with tRCD (min) and dataout is available with the shortest latency from the Bank Activate command (ACT). The internal precharge operation, however, does not begin until after tRAS (min) is satisfied. Burst Terminate The Burst Terminate command is used to truncate read bursts (with Auto Precharge disabled). The most re-cently registered Read command prior to the Burst Terminate command is truncated, as shown in the Operation section of this data sheet. Write burst cycles are not to be terminated with the Burst Terminate command. REV 1.3 06/2003 19 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Auto Refresh Auto Refresh is used during normal operation of the DDR SDRAM and is analogous to CAS Before RAS (CBR) Refresh in previous DRAM types. This command is nonpersistent, so it must be issued each time a refresh is required. The refresh addressing is generated by the internal refresh controller. This makes the address bits "Don't Care" during an Auto Refresh command. The 256Mb DDR SDRAM requires Auto Refresh cycles at an average periodic interval of 7.8s (maximum). Self Refresh The Self Refresh command can be used to retain data in the DDR SDRAM, even if the rest of the system is powered down. When in the self refresh mode, the DDR SDRAM retains data without external clocking. The Self Refresh command is initiated as an Auto Refresh command coincident with CKE transitioning low. The DLL is automatically disabled upon entering Self Refresh, and is automatically enabled upon exiting Self Refresh (200 clock cycles must then occur before a Read command can be issued). Input signals except CKE (low) are "Don't Care" during Self Refresh operation. The procedure for exiting self refresh requires a sequence of commands. CK (and CK) must be stable prior to CKE returning high. Once CKE is high, the SDRAM must have NOP commands issued for tXSNR because time is required for the completion of any internal refresh in progress. A simple algorithm for meeting both refresh and DLL requirements is to apply NOPs for 200 clock cycles before applying any other command. REV 1.3 06/2003 20 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Operations Bank/Row Activation Before any Read or Write commands can be issued to a bank within the DDR SDRAM, a row in that bank must be "opened" (activated). This is accomplished via the Active command and addresses A0-A12, BA0 and BA1 (see Activating a Specific Row in a Specific Bank), which decode and select both the bank and the row to be activated. After opening a row (issuing an Active command), a Read or Write command may be issued to that row, subject to the t RCD specification. A subsequent Active command to a different row in the same bank can only be issued after the previous active row has been "closed" (precharged). The minimum time interval between successive Active commands to the same bank is defined by tRC . A subsequent Active command to another bank can be issued while the first bank is being accessed, which results in a reduction of total row-access overhead. The minimum time interval between successive Active commands to different banks is defined by tRRD . Activating a Specific Row in a Specific Bank CK CK CKE HIGH CS RAS CAS WE REV 1.3 06/2003 A0-A12 RA BA0, BA1 BA RA = row address. BA = bank address. Don't Care 21 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM tRCD and t RRD Definition CK CK NOP ACT NOP ACT A0-A12 ROW ROW COL BA0, BA1 BA x BA y BA y tRRD NOP RD/WR Command NOP NOP tRCD Don't Care Reads Subsequent to programming the mode register with CAS latency, burst type, and burst length, Read bursts are initiated with a Read command. The starting column and bank addresses are provided with the Read command and Auto Precharge is either enabled or disabled for that burst access. If Auto Precharge is enabled, the row that is accessed starts precharge at the completion of the burst, provided t RAS has been satisfied. For the generic Read commands used in the following illustrations, Auto Precharge is disabled. During Read bursts, the valid data-out element from the starting column address is available following the CAS latency after the Read command. Each subsequent data-out element is valid nominally at the next positive or negative clock edge (i.e. at the next crossing of CK and CK). The following timing figure entitled "Read Burst: CAS Latencies (Burst Length=4)" illustrates the general timing for each supported CAS latency setting. DQS is driven by the DDR SDRAM along with output data. The initial low state on DQS is known as the read preamble; the low state coincident with the last data-out element is known as the read postamble. Upon completion of a burst, assuming no other commands have been initiated, the DQs and DQS goes High-Z. Data from any Read burst may be concatenated with or truncated with data from a subsequent Read command. In either case, a continuous flow of data can be maintained. The first data element from the new burst follows either the last element of a completed burst or the last desired data element of a longer burst which is being truncated. The new Read command should be issued x cycles after the first Read command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). This is shown in timing figure entitled "Consecutive Read Bursts: CAS Latencies (Burst Length =4 or 8)". A Read command can be initiated on any positive clock cycle following a previous Read command. Nonconsecutive Read data is shown in timing figure entitled "Non-Consecutive Read Bursts: CAS Latencies (Burst Length = 4)". Full-speed Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8) within a page (or pages) can be performed as shown on page 27. REV 1.3 06/2003 22 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Read Command CK CK CKE HIGH CS RAS CAS WE x4: A0-A9, A11 x8: A0-A9 CA EN AP A10 DIS AP BA0, BA1 BA CA = column address BA = bank address EN AP = enable Auto Precharge DIS AP = disable Auto Precharge Don't Care REV 1.3 06/2003 23 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Read Burst: CAS Latencies (Burst Length = 4) CAS Latency = 3 CK CK Command Address Read NOP NOP NOP NOP NOP BA a,COL n CL=3 DQS DQ DOa-n tQCS tQCH QFC (Optional) CAS Latency = 2.5 CK CK Command Address Read NOP NOP NOP NOP NOP BA a,COL n CL=2.5 DQS DOa-n DQ QFC tQ C S tQCH (Optional) Don't Care DO a-n = data out from bank a, column n. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC , tDQSCK , and t DQSQ . QFC is an open drain driver. The output high level is achieved through an external pull up resistor connected to V DDQ . REV 1.3 06/2003 24 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Consecutive Read Bursts: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 3 CK CK Command Address Read NOP Read BAa, COL n NOP NOP NOP BAa, COL b CL=3 DQS DQ DOa-b DOa-n CAS Latency = 2.5 CK CK Command Address Read NOP Read BAa, COL n NOP NOP NOP BAa,COL b CL=2.5 DQS DOa- n DQ DOa- b DO a-n (or a-b) = data out from bank a, column n (or bank a, column b). When burst length = 4, the bursts are concatenated. When burst length = 8, the second burst interrupts the first. 3 subsequent elements of data out appear in the programmed order following DO a-n. 3 (or 7) subsequent elements of data out appear in the programmed order following DO a-b. Shown with nominal t AC , tDQSCK, and t DQSQ. REV 1.3 06/2003 Don't Care 25 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Non-Consecutive Read Bursts: CAS Latencies (Burst Length = 4) CAS Latency = 3 CK CK Command Address Read NOP NOP Read BAa, COL n NOP NOP NOP BAa, COL b CL=3 DQS DQ DO a- n DOa- b CAS Latency = 2.5 CK CK Command Address Read NOP NOP Read BAa, COL n NOP NOP NOP BAa, COL b CL=2.5 DQS DQ DO a- n DOa- b DO a-n (or a-b) = data out from bank a, column n (or bank a, column b). 3 subsequent elements of data out appear in the programmed order following DO a-n (and following DO a- b). Shown with nominal tAC , tDQSCK, and t DQSQ. REV 1.3 06/2003 Don't Care 26 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Random Read Accesses: CAS Latencies (Burst Length = 2, 4 or 8) CAS Latency = 3 CK CK Command Address Read Read Read Read BAa, COL n BAa, COL x BAa, COL b BAa, COL g NOP NOP CL=3 DQS DOa-n DQ DOa-n' DOa-x DOa-x' DOa- b DOa-b' CAS Latency = 2.5 CK CK Command Address Read Read Read Read BAa, COL n BAa, COL x BAa, COL b BAa, COL g NOP NOP CL=2.5 DQS DQ DOa-n DO a-n, etc. = data out from bank a, column n etc. n' etc. = odd or even complement of n, etc. (i.e., column address LSB inverted). Reads are to active rows in any banks. Shown with nominal t AC , tDQSCK, and t DQSQ . REV 1.3 06/2003 DOa- n' DOa-x DOa-x' DOa-b DOa-b' Don't Care 27 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Data from any Read burst may be truncated with a Burst Terminate command, as shown in timing figure entitled Terminating a Read Burst: CAS Latencies (Burst Length = 8) on page 29. The Burst Terminate latency is equal to the read (CAS) latency, i.e. the Burst Terminate command should be issued x cycles after the Read command, where x equals the number of desired data element pairs. Data from any Read burst must be completed or truncated before a subsequent Write command can be issued. If truncation is necessary, the Burst Terminate command must be used, as shown in timing figure entitled Read to Write: CAS Latencies (Burst Length = 4 or 8) on page 30. The example is shown for t DQSS (min). The tDQSS (max) case, not shown here, has a longer bus idle time. t DQSS (min) and t DQSS(max) are defined in the section on Writes. A Read burst may be followed by, or truncated with, a Precharge command to the same bank (provided that Auto Precharge was not activated). The Precharge command should be issued x cycles after the Read command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). This is shown in timing figure Read to Precharge: CAS Latencies (Burst Length = 4 or 8) on page 31 for Read latencies of 2 and 2.5. Following the Precharge command, a subsequent command to the same bank cannot be issued until t RP is met. Note that part of the row precharge time is hidden during the access of the last data elements. In the case of a Read being executed to completion, a Precharge command issued at the optimum time (as described above) provides the same operation that would result from the same Read burst with Auto Precharge enabled. The disadvantage of the Precharge command is that it requires that the command and address busses be available at the appropriate time to issue the command. The advantage of the Precharge command is that it can be used to truncate bursts. REV 1.3 06/2003 28 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Terminating a Read Burst: CAS Latencies (Burst Length = 8) CAS Latency = 3 CK CK Command Address Read NOP BST NOP NOP NOP BAa, COL n CL=3 DQS DOa-n DQ No further output data after this point. DQS tristated. CAS Latency = 2.5 CK CK Command Address Read NOP BST NOP NOP NOP BAa, COL n CL=2.5 DQS DQ DOa-n No further output data after this point. DQS tristated. DO a-n = data out from bank a, column n. Cases shown are bursts of 8 terminated after 4 data elements. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal tAC , tDQSCK, and t DQSQ. REV 1.3 06/2003 Don't Care 29 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Read to Write: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 3 CK CK Command Address Read BST NOP NOP NOP Write BAa, COL b BAa, COL n t DQSS (min) CL=3 DQS DQ DIa-b DOa-n DM CAS Latency = 2.5 CK CK Command Address Read BST NOP NOP BAa, COL n Write NOP BAa, COL b CL=2.5 tDQSS (min) DQS DOa-n DQ Dla-b DM DO a-n = data out from bank a, column n .DI a-b = data in to bank a, column b 1 subsequent elements of data out appear in the programmed order following DO a-n. Data In elements are applied following Dl a-b in the programmed order, according to burst length. Shown with nominal t AC, tDQSCK , and tDQSQ. REV 1.3 06/2003 Don't Care 30 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Read to Precharge: CAS Latencies (Burst Length = 4 or 8) CAS Latency = 3 CK CK Command Read NOP PRE NOP NOP ACT tR P Address BA a, COL n BA a or all BA a, ROW CL=3 DQS DQ DOa-n CAS Latency = 2.5 CK CK Command Read NOP PRE NOP NOP ACT tR P Address BA a or all BA a, COL n BA a, ROW CL=2.5 DQS DOa-n DQ DO a-n = data out from bank a, column n. Cases shown are either uninterrupted bursts of 4 or interrupted bursts of 8. 3 subsequent elements of data out appear in the programmed order following DO a-n. Shown with nominal t AC , tDQSCK , and tDQSQ . REV 1.3 06/2003 Don't Care 31 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Writes Write bursts are initiated with a Write command, as shown in timing figure Write Command on page 33. The starting column and bank addresses are provided with the Write command, and Auto Precharge is either enabled or disabled for that access. If Auto Precharge is enabled, the row being accessed is precharged at the completion of the burst. For the generic Write commands used in the following illustrations, Auto Precharge is disabled. During Write bursts, the first valid data-in element is registered on the first rising edge of DQS following the write command, and subsequent data elements are registered on successive edges of DQS. The Low state on DQS between the Write command and the first rising edge is known as the write preamble; the Low state on DQS following the last data-in element is known as the write postamble. The time between the Write command and the first corresponding rising edge of DQS (tDQSS ) is specified with a relatively wide range (from 75% to 125% of one clock cycle), so most of the Write diagrams that follow are drawn for the two extreme cases (i.e. t DQSS (min) and tDQSS(max)). Timing figure Write Burst (Burst Length = 4) on page 34 shows the two extremes of tDQSS for a burst of four. Upon completion of a burst, assuming no other commands have been initiated, the DQs and DQS enters High-Z and any additional input data is ignored. Data for any Write burst may be concatenated with or truncated with a subsequent Write command. In either case, a continuous flow of input data can be maintained. The new Write command can be issued on any positive edge of clock following the previous Write command. The first data element from the new burst is applied after either the last element of a completed burst or the last desired data element of a longer burst which is being truncated. The new Write command should be issued x cycles after the first Write command, where x equals the number of desired data element pairs (pairs are required by the 2n prefetch architecture). Timing figure Write to Write (Burst Length = 4) on page 35 shows concatenated bursts of 4. An example of nonconsecutive Writes is shown in timing figure Write to Write: Max DQSS, Non-Consecutive (Burst Length = 4) on page 36. Fullspeed random write accesses within a page or pages can be performed as shown in timing figure Random Write Cycles (Burst Length = 2, 4 or 8) on page 37. Data for any Write burst may be followed by a subsequent Read command. To follow a Write without truncating the write burst, t WTR (Write to Read) should be met as shown in timing figure Write to Read: Non-Interrupting (CAS Latency = 3; Burst Length = 4) on page 38. Data for any Write burst may be truncated by a subsequent (interrupting) Read command. This is illustrated in timing figures "Write to Read: Interrupting (CAS Latency =2; Burst Length = 8)", "Write to Read: Minimum D QSS , Odd Number of Data (3 bit Write), Interrupting (CAS Latency = 2; Burst Length = 8)", and "Write to Read: Nominal DQSS, Interrupting (CAS Latency = 2; Burst Length = 8)". Note that only the data-in pairs that are registered prior to the t WTR period are written to the internal array, and any subsequent data-in must be masked with DM, as shown in the diagrams noted previously. Data for any Write burst may be followed by a subsequent Precharge command. To follow a Write without truncating the write burst, t WR should be met as shown in timing figure Write to Precharge: Non-Interrupting (Burst Length = 4) on page 42. Data for any Write burst may be truncated by a subsequent Precharge command, as shown in timing figures Write to Precharge: Interrupting (Burst Length = 4 or 8) on page 43 to Write to Precharge: Nominal DQSS (2 bit Write), Interrupting (Burst Length = 4 or 8) on page 45. Note that only the data-in pairs that are registered prior to the tWR period are written to the internal array, and any subsequent data in should be masked with DM. Following the Precharge command, a subsequent command to the same bank cannot be issued until tRP is met. In the case of a Write burst being executed to completion, a Precharge command issued at the optimum time (as described above) provides the same operation that would result from the same burst with Auto Precharge. The disadvantage of the Precharge command is that it requires that the command and address busses be available at the appropriate time to issue the command. The advantage of the Precharge command is that it can be used to truncate bursts. REV 1.3 06/2003 32 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write Command CK CK CKE HIGH CS RAS CAS WE x4: A0-A9, A11 x8: A0-A9 CA EN AP A10 DIS AP BA0, BA1 BA CA = column address BA = bank address EN AP = enable Auto Precharge DIS AP = disable Auto Precharge Don't Care REV 1.3 06/2003 33 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write Burst (Burst Length = 4) Maximum DQSS T1 T2 T3 T4 CK CK Command Address Write NOP NOP NOP BA a, COL b tDQSS (max) DQS Dla-b DQ DM tQCSW (max) tQCHW (min) QFC (Optional) Minimum DQSS T1 T2 T3 T4 CK CK Command Address Write NOP NOP NOP BA a, COL b tDQSS (min) DQS DQ Dla-b DM tQCSW (max) tQCHW(max) QFC DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a- b. A non-interrupted burst is shown. A10 is Low with the Write command (Auto Precharge is disabled). QFC is an open drain driver. Its output high level is achieved through an externally connected pull up resistor connected to V DDQ . Don't Care REV 1.3 06/2003 34 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Write (Burst Length = 4) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Address Write NOP Write BAa, COL b NOP NOP NOP BAa, COL n tDQSS (max) DQS DI a-b DQ DI a-n DM Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Address Write NOP BA, COL b Write NOP NOP NOP BA, COL n tDQSS (min) DQS DQ DI a-b DI a-n DM DI a-b = data in for bank a, column b, etc. 3 subsequent elements of data in are applied in the programmed order following DI a-b. 3 subsequent elements of data in are applied in the programmed order following DI a-n. A non-interrupted burst is shown. Each Write command may be to any bank. REV 1.3 06/2003 Don't Care 35 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Write: Max DQSS, Non-Consecutive (Burst Length = 4) T1 T2 T3 T4 T5 CK CK Command Address Write NOP NOP BAa, COL b Write NOP BAa, COL n tDQSS (max) DQS DQ DI a-b DI a-n DM DI a-b, etc. = data in for bank a, column b, etc. 3 subsequent elements of data in are applied in the programmed order following DI a-b. 3 subsequent elements of data in are applied in the programmed order following DI a-n. A non-interrupted burst is shown. Each Write command may be to any bank. REV 1.3 06/2003 Don't Care 36 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Random Write Cycles (Burst Length = 2, 4 or 8) Maximum DQSS T1 T2 T3 T4 T5 CK CK Command Address Write Write BAa, COL b Write BAa, COL x Write BAa, COL n Write BAa, COL a BAa, COL g tDQSS (max) DQS DI a-b DQ DI a-b' DI a-x DI a-x' DI a-n DI a-n' DI a-a DI a-a' DM Minimum D QSS T1 T2 T3 T4 T5 CK CK Command Address Write Write BAa, COL b Write BAa, COL x Write BAa, COL n Write BAa, COL a BAa, COL g tDQSS (min) DQS DQ DI a-b DI a-b' DI a-x DI a-x' DI a-n DI a-n' DI a-a DI a-a' DI a-g DM DI a-b, etc. = data in for bank a, column b, etc. b', etc. = odd or even complement of b, etc. (i.e., column address LSB inverted). Each Write command may be to any bank. REV 1.3 06/2003 Don't Care 37 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Read: Non-Interrupting (CAS Latency = 3; Burst Length = 4) Maximum D QSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL b BAa, COL n CL = 3 tDQSS (max) DQS DI a- b DQ DM Minimum D QSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL b BAa, COL n CL = 3 tDQSS (min) DQS DQ DI a- b DM DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a-b. A non-interrupted burst is shown. tWTR is referenced from the first positive CK edge after the last data in pair. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands may be to any bank. REV 1.3 06/2003 Don't Care 38 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Read: Interrupting (CAS Latency = 3; Burst Length = 8) Maximum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tW T R Address BAa, COL n BAa, COL b CL = 3 tDQSS (max) DQS DQ DIa- b 1 DM 1 Minimum D QSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL b BAa, COL n CL = 3 tDQSS (min) DQS DQ DI a-b DM 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 4 data elements are written. 3 subsequent elements of data in are applied in the programmed order following DI a-b. tWTR is referenced from the first positive CK edge after the last data in pair. The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = These bits are incorrectly written into the memory array if DM is low. REV 1.3 06/2003 Don't Care 39 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Read: Minimum DQSS, Odd Number of Data (3 bit Write), Interrupting (CAS Latency = 3; Burst Length = 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tW T R Address BAa, COL b BAa, COL n CL = 3 tDQSS (min) DQS DQ DI a-b 1 DM 2 2 DI a- b = data in for bank a, column b. An interrupted burst is shown, 3 data elements are written. 2 subsequent elements of data in are applied in the programmed order following DI a-b . tWTR is referenced from the first positive CK edge after the last desired data in pair (not the last desired data in element) The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = This bit is correctly written into the memory array if DM is low. Don't Care 2 = These bits are incorrectly written into the memory array if DM is low. REV 1.3 06/2003 40 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Read: Nominal DQSS, Interrupting (CAS Latency = 3; Burst Length = 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP Read NOP tWTR Address BAa, COL n BAa, COL b CL = 3 tDQSS (nom) DQS DQ DI a- b DM 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 4 data elements are written. 3 subsequent elements of data in are applied in the programmed order following DI a-b. tWTR is referenced from the first positive CK edge after the last desired data in pair. The Read command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). The Read and Write commands are not necessarily to the same bank. 1 = These bits are incorrectly written into the memory array if DM is low. REV 1.3 06/2003 Don't Care 41 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Precharge: Non-Interrupting (Burst Length = 4) Maximum D QSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP NOP PRE tWR Address BA a, COL b BA (a or all) tRP tDQSS (max) DQS DI a-b DQ DM Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP NOP PRE tWR Address BA a, COL b BA (a or all) tRP tDQSS (min) DQS DQ DI a-b DM DI a-b = data in for bank a, column b. 3 subsequent elements of data in are applied in the programmed order following DI a-b. A non-interrupted burst is shown. tWR is referenced from the first positive CK edge after the last data in pair. A10 is Low with the Write command (Auto Precharge is disabled). REV 1.3 06/2003 Don't Care 42 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Precharge: Interrupting (Burst Length = 4 or 8) Maximum D QSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA a, COL b BA (a or all) tDQSS (max) tR P 2 DQS DI a-b DQ 3 DM 3 1 1 Minimum DQSS T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA a, COL b BA (a or all) tDQSS (min) tR P 2 DQS DQ DM DI a-b 3 3 1 1 DI a- b = data in for bank a, column b. An interrupted burst is shown, 2 data elements are written. 1 subsequent element of data in is applied in the programmed order following DI a-b. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst, for burst length = 8. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = These bits are incorrectly written into the memory array if DM is low. REV 1.3 06/2003 Don't Care 43 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Precharge: Minimum DQSS, Odd Number of Data (1 bit Write), Interrupting (Burst Length = 4 or 8) T1 T2 T3 T4 T5 T6 CK CK Command Write NOP NOP NOP PRE NOP tWR Address BA a, COL b BA (a or all) tDQSS (min) tRP 2 DQS DQ DM DI a-b 3 4 4 1 1 DI a-b = data in for bank a, column b. An interrupted burst is shown, 1 data element is written. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = This bit is correctly written into the memory array if DM is low. 4 = These bits are incorrectly written into the memory array if DM is low. REV 1.3 06/2003 Don't Care 44 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Write to Precharge: Nominal DQSS (2 bit Write), Interrupting (Burst Length = 4 or 8) T1 T2 T3 T4 T5 T6 CK CK Write Command NOP NOP NOP PRE NOP tWR Address BA a, COL b BA (a or all) tDQSS (nom) tRP 2 DQS DQ DM DI a-b 3 3 1 1 DI a-b = Data In for bank a, column b. An interrupted burst is shown, 2 data elements are written. 1 subsequent element of data in is applied in the programmed order following DI a-b. tWR is referenced from the first positive CK edge after the last desired data in pair. The Precharge command masks the last 2 data elements in the burst. A10 is Low with the Write command (Auto Precharge is disabled). 1 = Can be don't care for programmed burst length of 4. 2 = For programmed burst length of 4, DQS becomes don't care at this point. 3 = These bits are incorrectly written into the memory array if DM is low. REV 1.3 06/2003 Don't Care 45 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Precharge Command CK CK CKE HIGH CS RAS CAS WE A0-A9, A11, A12 All Banks A10 BA0, BA1 One Bank BA BA = bank address (if A10 is Low, otherwise Don't Care). Don't Care Precharge The Precharge command is used to deactivate the open row in a particular bank or the open row in all banks. The bank(s) is available for a subsequent row access some specified time (tRP) after the Precharge command is issued. Input A10 determines whether one or all banks are to be precharged, and in the case where only one bank is to be precharged, inputs BA0, BA1 select the bank. When all banks are to be precharged, inputs BA0, BA1 are treated as "Don't Care." Once a bank has been precharged, it is in the idle state and must be activated prior to any Read or Write commands being issued to that bank. REV 1.3 06/2003 46 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Power Down Power Down is entered when CKE is registered low (no accesses can be in progress). If Power Down occurs when all banks are idle, this mode is referred to as Precharge Power Down; if Power Down occurs when there is a row active in any bank, this mode is referred to as Active Power Down. Entering Power Down deactivates the input and output buffers, excluding CK, CK and CKE. The DLL is still running in Power Down mode, so for maximum power savings, the user has the option of disabling the DLL prior to entering Power Down. In that case, the DLL must be enabled after exiting Power Down, and 200 clock cycles must occur before a Read command can be issued. In Power Down mode, CKE Low and a stable clock signal must be maintained at the inputs of the DDR SDRAM, and all other input signals are "Don't Care". However, Power Down duration is limited by the refresh requirements of the device, so in most applications, the self refresh mode is preferred over the DLL-disabled Power Down mode. The Power Down state is synchronously exited when CKE is registered high (along with a Nop or Deselect command). A valid, executable command may be applied one clock cycle later. Power Down CK CK tIS CKE Command VALID tIS NOP No column access in progress Exit power down mode Enter Power Down mode (Burst Read or Write operation must not be in progress) REV 1.3 06/2003 VALID NOP tPDEX Don't Care 47 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Truth Table 2: Clock Enable (CKE) 1. 2. 3. 4. CKE n is the logic state of CKE at clock edge n: CKE n-1 was the state of CKE at the previous clock edge. Current state is the state of the DDR SDRAM immediately prior to clock edge n. Command n is the command registered at clock edge n, and action n is a result of command n. All states and sequences not shown are illegal or reserved. CKE n-1 CKEn Current State Previous Cycle Current Cycle Command n Self Refresh L L X Self Refresh L H Deselect or NOP Power Down L L X Power Down L H Deselect or NOP Exit Power Down All Banks Idle H L Deselect or NOP Precharge Power Down Entry All Banks Idle H L Auto Refresh Bank(s) Active H L Deselect or NOP H H See "Truth Table 3: Current State Bank n - Command to Bank n (Same Bank) " on page 49 Action n Notes Maintain Self-Refresh Exit Self-Refresh 1 Maintain Power Down Self Refresh Entry Active Power Down Entry 1. Deselect or NOP commands should be issued on any clock edges occurring during the Self Refresh Exit (t XSNR) period. A minimum of 200 clock cycles are needed before applying a read command to allow the DLL to lock to the input clock. REV 1.3 06/2003 48 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Truth Table 3: Current State Bank n - Command to Bank n (Same Bank) Current State CS RAS CAS WE Command Action Notes H X X X Deselect NOP. Continue previous operation 1-6 L H H H No Operation NOP. Continue previous operation 1-6 L L H H Active Select and activate row 1-6 L L L H Auto Refresh L L L L Mode Register Set L H L H Read Select column and start Read burst 1-6, 10 L H L L Write Select column and start Write burst 1-6, 10 L L H L Precharge L H L H Read L L H L Precharge L H H L Burst Terminate L H L H Read Select column and start Read burst 1-6, 10, 11 L H L L Write Select column and start Write burst 1-6, 10 L L H L Precharge Any Idle Row Active Read (Auto Precharge Disabled) Write (Auto Precharge Disabled) 1-7 1-7 Deactivate row in bank(s) 1-6, 8 Select column and start new Read burst 1-6, 10 Truncate Read burst, start Precharge 1-6, 8 Burst Terminate 1-6, 9 Truncate Write burst, start Precharge 1-6, 8, 11 1. This table applies when CKE n-1 was high and CKE n is high (see Truth Table 2: Clock Enable (CKE) and after t XSNR / tXSRD has been met (if the previous state was self refresh). 2. This table is bank-specific, except where noted, i.e., the current state is for a specific bank and the commands shown are those allowed to be issued to that bank when in that state. Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and t RP has been met. Row Active: A row in the bank has been activated, and tRCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. 4. The following states must not be interrupted by a command issued to the same bank. Precharging: Starts with registration of a Precharge command and ends when t R P is met. Once t RP is met, the bank is in the idle state. Row Activating: Starts with registration of an Active command and ends when t RCD is met. Once t RCD is met, the bank is in the "row active" state. Read w/Auto Precharge Enabled: Starts with registration of a Read command with Auto Precharge enabled and ends when t RP has been met. Once t RP is met, the bank is in the idle state. Write w/Auto Precharge Enabled: Starts with registration of a Write command with Auto Precharge enabled and ends when tRP has been met. Once t RP is met, the bank is in the idle state. Deselect or NOP commands, or allowable commands to the other bank should be issued on any clock edge occurring during these states. Allowable commands to the other bank are determined by its current state and according to Truth Table 4. 5. The following states must not be interrupted by any executable command; Deselect or NOP commands must be applied on each positive clock edge during these states. Refreshing: Starts with registration of an Auto Refresh command and ends when t RFC is met. Once t RFC is met, the DDR SDRAM is in the "all banks idle" state. Accessing Mode Register: Starts with registration of a Mode Register Set command and ends when tMRD has been met. Once t MRD is met, the DDR SDRAM is in the "all banks idle" state. Precharging All: Starts with registration of a Precharge All command and ends when t RP is met. Once t RP is met, all banks is in the idle state. 6. All states and sequences not shown are illegal or reserved. 7. Not bank-specific; requires that all banks are idle. 8. May or may not be bank-specific; if all/any banks are to be precharged, all/any must be in a valid state for precharging. 9. Not bank-specific; Burst terminate affects the most recent Read burst, regardless of bank. 10. Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads or Writes with Auto Precharge disabled. 11. Requires appropriate DM masking. REV 1.3 06/2003 49 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Truth Table 4: Current State Bank n - Command to Bank m (Different bank) (Part 1 of 2) Current State CS RAS CAS WE Command Action Notes H X X X Deselect NOP/continue previous operation 1-6 L H H H No Operation NOP/continue previous operation 1-6 X X X X Any Command Otherwise Allowed to Bank m L L H H Active Select and activate row 1-6 L H L H Read Select column and start Read burst 1-7 L H L L Write Select column and start Write burst 1-7 L L H L Precharge L L H H Active Select and activate row 1-6 L H L H Read Select column and start new Read burst 1-7 L L H L Precharge L L H H Active Select and activate row 1-6 L H L H Read Select column and start Read burst 1-8 L H L L Write Select column and start new Write burst 1-7 L L H L Precharge Any Idle Row Activating, Active, or Precharging Read (Auto Precharge Disabled) Write (Auto Precharge Disabled) 1-6 1-6 1-6 1-6 1. This table applies when CKE n-1 was high and CKE n is high (see Truth Table 2: Clock Enable (CKE) and after t XSNR / tXSRD has been met (if the previous state was self refresh). 2. This table describes alternate bank operation, except where noted, i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and t RP has been met. Row Active: A row in the bank has been activated, and t RCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Read with Auto Precharge Enabled: See note 10. Write with Auto Precharge Enabled: See note 10. 4. Auto Refresh and Mode Register Set commands may only be issued when all banks are idle. 5. A Burst Terminate command cannot be issued to another bank; it applies to the bank represented by the current state only. 6. All states and sequences not shown are illegal or reserved. 7. Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads or Writes with Auto Precharge disabled. 8. Requires appropriate DM masking. 9. A Write command may be applied after the completion of data output. 10. The Read with Auto Precharge enabled or Write with Auto Precharge enabled states can each be broken into two parts: the access period and the precharge period. For Read with Auto Precharge, the precharge period is defined as if the same burst was executed with Auto Precharge disabled and then followed with the earliest possible Precharge command that still accesses all of the data in the burst. For Write with Auto Precharge, the precharge period begins when tWR ends, with tWR measured as if Auto Precharge was disabled. The access period starts with registration of the command and ends where the precharge period (or t R P) begins. During the precharge period of the Read with Auto Precharge Enabled or Write with Auto Precharge Enabled states, Active, Precharge, Read, and Write commands to the other bank may be applied; during the access period, only Active and Precharge commands to the other bank may be applied. In either case, all other related limitations apply (e.g. contention between Read data and Write data must be avoided). REV 1.3 06/2003 50 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Truth Table 4: Current State Bank n - Command to Bank m (Different bank) (Part 2 of 2) Current State Read (With Auto Precharge) Write (With Auto Precharge) CS RAS CAS WE Command L L H H Active Select and activate row Action Notes L H L H Read Select column and start new Read burst L H L L Write Select column and start Write burst L L H L Precharge L L H H Active Select and activate row L H L H Read Select column and start Read burst 1-7,10 L H L L Write Select column and start new Write burst 1-7,10 L L H L Precharge 1-6 1-7,10 1-7,9,10 1-6 1-6 1-6 1. This table applies when CKE n-1 was high and CKE n is high (see Truth Table 2: Clock Enable (CKE) and after t XSNR / tXSRD has been met (if the previous state was self refresh). 2. This table describes alternate bank operation, except where noted, i.e., the current state is for bank n and the commands shown are those allowed to be issued to bank m (assuming that bank m is in such a state that the given command is allowable). Exceptions are covered in the notes below. 3. Current state definitions: Idle: The bank has been precharged, and t RP has been met. Row Active: A row in the bank has been activated, and t RCD has been met. No data bursts/accesses and no register accesses are in progress. Read: A Read burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Write: A Write burst has been initiated, with Auto Precharge disabled, and has not yet terminated or been terminated. Read with Auto Precharge Enabled: See note 10. Write with Auto Precharge Enabled: See note 10. 4. Auto Refresh and Mode Register Set commands may only be issued when all banks are idle. 5. A Burst Terminate command cannot be issued to another bank; it applies to the bank represented by the current state only. 6. All states and sequences not shown are illegal or reserved. 7. Reads or Writes listed in the Command/Action column include Reads or Writes with Auto Precharge enabled and Reads or Writes with Auto Precharge disabled. 8. Requires appropriate DM masking. 9. A Write command may be applied after the completion of data output. 10. The Read with Auto Precharge enabled or Write with Auto Precharge enabled states can each be broken into two parts: the access period and the precharge period. For Read with Auto Precharge, the precharge period is defined as if the same burst was executed with Auto Precharge disabled and then followed with the earliest possible Precharge command that still accesses all of the data in the burst. For Write with Auto Precharge, the precharge period begins when tWR ends, with tWR measured as if Auto Precharge was disabled. The access period starts with registration of the command and ends where the precharge period (or t R P) begins. During the precharge period of the Read with Auto Precharge Enabled or Write with Auto Precharge Enabled states, Active, Precharge, Read, and Write commands to the other bank may be applied; during the access period, only Active and Precharge commands to the other bank may be applied. In either case, all other related limitations apply (e.g. contention between Read data and Write data must be avoided). REV 1.3 06/2003 51 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Simplified State Diagram Power Applied Power On Self Refresh Precharge Preall REFS REFSX MRS EMRS MRS Auto Refresh REFA Idle CKEL CKEH Active Power Down ACT Precharge Power Down CKEH CKEL Burst Stop Row Active Write Write A Write Read Read A Read Read Write A Read A Read A PRE Write A PRE PRE PRE Read A Precharge Preall Automatic Sequence Command Sequence PREALL = Precharge All Banks MRS = Mode Register Set EMRS = Extended Mode Register Set REFS = Enter Self Refresh REFSX = Exit Self Refresh REFA = Auto Refresh REV 1.3 06/2003 CKEL = Enter Power Down CKEH = Exit Power Down ACT = Active Write A = Write with Autoprecharge Read A = Read with Autoprecharge PRE = Precharge 52 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Absolute Maximum Ratings Symbol V IN , V OUT Parameter Voltage on I/O pins relative to VSS Rating Units -0.5 to V DDQ + 0.5 V VI N Voltage on Inputs relative to VSS - 0.5 to + 3.6 V V DD Voltage on V D D supply relative to VSS - 0.5 to + 3.6 V Voltage on V DDQ supply relative to VSS - 0.5 to + 3.6 V V DDQ TA T STG PD IOUT Operating Temperature (Ambient) 0 to +70 C - 55 to + 150 C Power Dissipation 1.0 W Short Circuit Output Current 50 mA Storage Temperature (Plastic) Note: Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. DQS/DQ/DM Slew Rate Parameter DCS/DQ/DM input slew rate Symbol DC SLEW DDR400 (-5) Min Max TBD TBD Unit Notes V/ns 1, 2 1. Measured between V IH (DC), V IL (DC), and V IL (DC), V IH (DC). 2. DQS, DQ, and DM input slew rate is specified to prevent double clocking of data and preserve setup and hold times. Signal transition through the DC region must be monotonic. REV 1.3 06/2003 53 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Capacitance Parameter Input Capacitance: CK, CK Delta Input Capacitance: CK, CK Symbol Min. Max. Units Notes CI 1 2.0 3.0 pF 1 0.25 pF 1 3.0 pF 1 0.5 pF 1 5.0 pF 1, 2 0.5 pF 1 delta CI 1 Input Capacitance: All other input-only pins (except DM) CI 2 Delta Input Capacitance: All other input-only pins (except DM) 2.0 delta CI 2 Input/Output Capacitance: DQ, DQS, DM C IO Delta Input/Output Capacitance: DQ, DQS, DM 4.0 delta C IO 1. V DDQ = V D D = 2.6V 0.1V (minimum range to maximum range), f = 100MHz, TA = 25 C, VO DC = V DDQ/2 , VOPeak -Peak =0.2V. 2. Although DM is an input-only pin, the input capacitance of this pin must model the input capacitance of the DQ and DQS pins. This is required to match input propagation times of DQ, DQS and DM in the system. DC Electrical Characteristics and Operating Conditions (0C TA 70x C; VDDQ = +2.6V 0.1V, VDD = +2.6V 0.1V, see AC Characteristics) Symbol Min Max Units Notes Supply Voltage 2.5 2.7 V 1 V DDQ I/O Supply Voltage 2.5 2.7 V 1 V SS , VSSQ Supply Voltage I/O Supply Voltage 0 0 V I/O Reference Voltage 0.49 x V DDQ 0.51 x V DDQ V 1, 2 V DD V REF Parameter I/O Termination Voltage (System) V REF - 0.04 V REF + 0.04 V 1, 3 V IH(DC) Input High (Logic1) Voltage V REF + 0.15 V DDQ + 0.3 V 1 V IL(DC) Input Low (Logic0) Voltage - 0.3 V REF - 0.15 V 1 V IN(DC) Input Voltage Level, CK and CK Inputs - 0.3 V DDQ + 0.3 V 1 V ID(DC) Input Differential Voltage, CK and CK Inputs 0.30 V DDQ + 0.6 V 1, 4 V IX(DC) Input Crossing Point Voltage, CK and CK Inputs 0.30 V DDQ + 0.6 V 1, 4 VI Ratio V-I Matching Pullup Current to Pulldown Current Ratio 0.71 1.4 II Input Leakage Current Any input 0V V IN V D D; (All other pins not under test -5 5 A 1 -5 5 A 1 mA 1 V TT IOZ IO H IOL = 0V) Output Leakage Current (DQs are disabled; 0V V out V DDQ Output Current: Nominal Strength Driver High current (VOUT = V DDQ -0.373V, min V REF, min VTT ) Low current (VOUT = 0.373V, max V REF, max V TT ) 5 - 16.8 16.8 1. Inputs are not recognized as valid until V REF stabilizes. 2. V REF is expected to be equal to 0.5 VDDQ of the transmitting device, and to track variations in the DC level of the same. Peak-to-peak noise on VREF may not exceed 2% of the DC value. 3. V TT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be set equal to VREF, and must track variations in the DC level of V REF . 4. V ID is the magnitude of the difference between the input level on CK and the input level on CK . 5. The ratio of the pullup current to the pulldown current is specified for the same temperature and voltage, over the entire temperature and voltage range, for device drain to source voltages for 0.25 volts to 1.0 volts. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. REV 1.3 06/2003 54 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM DC Electrical Characteristics and Operating Conditions (0C TA 70x C; VDDQ = +2.6V 0.1V, VDD = +2.6V 0.1V, see AC Characteristics) Symbol IOHW IOLW Parameter Min Max Units Notes mA 1 - 9.0 Output Current: Half- Strength Driver High current (VOUT = V DDQ -0.763V, min V REF, min VTT ) Low current (VOUT = 0.763V, max V REF, max V TT ) 9.0 1. Inputs are not recognized as valid until V REF stabilizes. 2. V REF is expected to be equal to 0.5 VDDQ of the transmitting device, and to track variations in the DC level of the same. Peak-to-peak noise on VREF may not exceed 2% of the DC value. 3. V TT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be set equal to VREF, and must track variations in the DC level of V REF . 4. V ID is the magnitude of the difference between the input level on CK and the input level on CK . 5. The ratio of the pullup current to the pulldown current is specified for the same temperature and voltage, over the entire temperature and voltage range, for device drain to source voltages for 0.25 volts to 1.0 volts. For a given output, it represents the maximum difference between pullup and pulldown drivers due to process variation. Normal Strength Driver Pulldown and Pullup Characteristics 1. The full variation in driver pulldown current from minimum to maximum process, temperature and voltage will lie within the outer bounding lines of the V-I curve. 2. It is recommended that the "typical" IBIS pulldown V-I curve lie within the shaded region of the V-I curve. Normal Strength Driver Pulldown Characteristics 140 IOUT (mA) Maximum Typical High Typical Low Minimum 0 0 2.7 VOUT (V) 3. The full variation in driver pullup current from minimum to maximum process, temperature and voltage will lie within the outer bounding lines of the V-I curve. 4. It is recommended that the "typical" IBIS pullup V-I curve lie within the shaded region of the V-I curve. REV 1.3 06/2003 55 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Normal Strength Driver Pullup Characteristics 0 Minimum IOUT (mA) Typical Low Typical High Maximum -200 0 VOUT (V) 2.7 5. The full variation in the ratio of the maximum to minimum pullup and pulldown current will not exceed 1.7, for device drain to source voltages from 0.1 to 1.0. 6. The full variation in the ratio of the "typical" IBIS pullup to "typical" IBIS pulldown current should be unity + 10%, for device drain to source voltages from 0.1 to 1.0. This specification is a design objective only. It is not guaranteed. 7. These characteristics are intended to obey the SSTL_2 class II standard. 8. This specification is intended for DDR SDRAM only. REV 1.3 06/2003 56 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Normal Strength Driver Pulldown and Pullup Currents Pulldown Current (mA) Pullup Current (mA) Voltage (V) Typical Low Typical High Min Max Typical Low Typical High Min Max 0.1 6.0 6.8 4.6 9.6 -6.1 -7.6 -4.6 -10.0 0.2 12.2 13.5 9.2 18.2 -12.2 -14.5 -9.2 -20.0 0.3 18.1 20.1 13.8 26.0 -18.1 -21.2 -13.8 -29.8 0.4 24.1 26.6 18.4 33.9 -24.0 -27.7 -18.4 -38.8 0.5 29.8 33.0 23.0 41.8 -29.8 -34.1 -23.0 -46.8 0.6 34.6 39.1 27.7 49.4 -34.3 -40.5 -27.7 -54.4 0.7 39.4 44.2 32.2 56.8 -38.1 -46.9 -32.2 -61.8 0.8 43.7 49.8 36.8 63.2 -41.1 -53.1 -36.0 -69.5 0.9 47.5 55.2 39.6 69.9 -43.8 -59.4 -38.2 -77.3 1.0 51.3 60.3 42.6 76.3 -46.0 -65.5 -38.7 -85.2 1.1 54.1 65.2 44.8 82.5 -47.8 -71.6 -39.0 -93.0 1.2 56.2 69.9 46.2 88.3 -49.2 -77.6 -39.2 -100.6 1.3 57.9 74.2 47.1 93.8 -50.0 -83.6 -39.4 -108.1 1.4 59.3 78.4 47.4 99.1 -50.5 -89.7 -39.6 -115.5 1.5 60.1 82.3 47.7 103.8 -50.7 -95.5 -39.9 -123.0 1.6 60.5 85.9 48.0 108.4 -51.0 -101.3 -40.1 -130.4 1.7 61.0 89.1 48.4 112.1 -51.1 -107.1 -40.2 -136.7 1.8 61.5 92.2 48.9 115.9 -51.3 -112.4 -40.3 -144.2 1.9 62.0 95.3 49.1 119.6 -51.5 -118.7 -40.4 -150.5 2.0 62.5 97.2 49.4 123.3 -51.6 -124.0 -40.5 -156.9 2.1 62.9 99.1 49.6 126.5 -51.8 -129.3 -40.6 -163.2 2.2 63.3 100.9 49.8 129.5 -52.0 -134.6 -40.7 -169.6 2.3 63.8 101.9 49.9 132.4 -52.2 -139.9 -40.8 -176.0 2.4 64.1 102.8 50.0 135.0 -52.3 -145.2 -40.9 -181.3 2.5 64.6 103.8 50.2 137.3 -52.5 -150.5 -41.0 -187.6 2.6 64.8 104.6 50.4 139.2 -52.7 -155.3 -41.1 -192.9 2.7 65.0 105.4 50.5 140.8 -52.8 -160.1 -41.2 -198.2 Normal Strength Driver Evaluation Conditions REV 1.3 06/2003 Typical Minimum Maximum Temperature (T ambient) 25 C 70 C 0 C V DDQ 2.5V 2.3V 2.7V Process conditions typical process slow-slow process fast-fast process 57 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM AC Characteristics (Notes 1-5 apply to the following Tables; Electrical Characteristics and DC Operating Conditions, AC Operating Conditions, I DD Specifications and Conditions, and Electrical Characteristics and AC Timing.) 1. All voltages referenced to V S S. 2. Tests for AC timing, IDD , and electrical, AC and DC characteristics, may be conducted at nominal reference/supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified. 3. Outputs measured with equivalent load. Refer to the AC Output Load Circuit below. 4. AC timing and I DD tests may use a VIL to VIH swing of up to 1.5V in the test environment, but input timing is still referenced to VREF (or to the crossing point for CK, CK), and parameter specifications are guaranteed for the specified AC input levels under normal use conditions. The minimum slew rate for the input signals is 1V/ns in the range between VIL(AC) and VIH(AC). 5. The AC and DC input level specifications are as defined in the SSTL_2 Standard (i.e. the receiver effectively switches as a result of the signal crossing the AC input level, and remains in that state as long as the signal does not ring back above (below) the DC input low (high) level. AC Output Load Circuit Diagrams V TT 50 Output (V OUT ) Timing Reference Point 30pF REV 1.3 06/2003 58 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM AC Input Operating Conditions (0 C T A 70 C; VDDQ = +2.6V 0.1V; VDD = +2.6V 0.1V, See AC Characteristics) Symbol Parameter/Condition V IH(AC) Input High (Logic 1) Voltage, DQ, DQS, and DM Signals V IL(AC) Input Low (Logic 0) Voltage, DQ, DQS, and DM Signals V ID(AC) Input Differential Voltage, CK and CK Inputs V IX(AC) Input Crossing Point Voltage, CK and CK Inputs Min Max Unit Notes V 1, 2 V REF - 0.31 V 1, 2 0.62 V DDQ + 0.6 V 1, 2, 3 0.5*V DDQ - 0.2 0.5*V DDQ + 0.2 V 1, 2, 4 V REF + 0.31 1. Input slew rate = 1V/ns . 2. Inputs are not recognized as valid until VREF stabilizes. 3. V ID is the magnitude of the difference between the input level on CK and the input level on CK . 4. The value of VIX is expected to equal 0.5*V DDQ of the transmitting device and must track variations in the DC level of the same. IDD Specifications and Conditions (0 C T A 70 C; VDDQ = +2.6V 0.1V; VDD = +2.6V 0.1V, See AC Characteristics) Symbol Parameter/Condition DDR400A (-5) tCK =5ns DDR400B (-5T) tCK =5ns Unit Notes IDD0 Operating Current: one bank; active / precharge; tRC = t R C (min); DQ, DM, and DQS inputs changing twice per clock cycle; address and control inputs changing once per clock cycle 115 115 mA 1 IDD1 Operating Current: one bank; active / read / precharge; Burst = 2; t RC = tR C (min); CL = 2.5; IOUT = 0mA; address and control inputs changing once per clock cycle 120 120 mA 1 IDD2P Precharge Power Down Standby Current: all banks idle; Power Down mode; CKE V IL (max) 20 20 mA 1 IDD2N Idle Standby Current: CS V I H (min); all banks idle; CKE V IH (min); address and control inputs changing once per clock cycle 45 45 mA 1 IDD3P Active Power Down Standby Current: one bank active; Power Down mode; CKE V IL (max) 21 21 mA 1 IDD3N Active Standby Current: one bank; active / precharge; CS V IH (min); CKE V I H (min); tRC = t RAS (max); DQ, DM, and DQS inputs changing twice per clock cycle; address and control inputs changing once per clock cycle 75 75 mA 1 IDD4R Operating Current: one bank; Burst = 2; reads; continuous burst; address and control inputs changing once per clock cycle; DQ and DQS outputs changing twice per clock cycle; CL = 2.5; IOUT = 0mA 200 200 mA 1 IDD4W Operating Current: one bank; Burst = 2; writes; continuous burst; address and control inputs changing once per clock cycle; DQ and DQS inputs changing twice per clock cycle; CL = 2.5 195 195 mA 1 IDD5 Auto-Refresh Current: tRC = tRFC (min) 225 225 mA 1 IDD6 Self-Refresh Current: CKE 0.2V 3 3 mA 1, 2 IDD7 Operating current: four bank; four bank interleaving with BL = 4, address and control inputs randomly changing; 50% of data changing at every transfer; t RC = t RC (min); I OUT = 0mA. 325 325 mA 1 1. IDD specifications are tested after the device is properly initialized. 2. Enables on-chip refresh and address counters. REV 1.3 06/2003 59 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Electrical Characteristics & AC Timing - Absolute Specifications (0 C T A 70 C; VDDQ = +2.6V 0.1V; VDD = 2.6V 0.1V, See AC Characteristics) (Part 1 of 2) Symbol DDR400 (-5) Parameter DDR400 (-5T) Unit Notes + 0.65 ns 1-4 - 0.55 + 0.55 ns 1-4 0.55 0.45 0.55 tCK 1-4 0.45 0.55 0.45 0.55 tCK 1-4 CL = 3.0 5 8 5 8 ns 1-4 CL = 2.5 5 12 6 12 0.4 ns 1-4, 15, 16 0.4 0.4 ns 1-4, 15, 16 Input pulse width 2.2 2.2 ns 2-4, 12 tDIPW DQ and DM input pulse width (each input) 1.75 1.75 ns 1-4 tH Z Data-out high-impedance time from CK/CK - 0.6 + 0.6 - 0.6 + 0.6 ns 1-4, 5 tLZ Data-out low-impedance time from CK/CK - 0.6 + 0.6 - 0.6 + 0.6 ns 1-4, 5 Min Max Min Max DQ output access time from CK/CK - 0.6 + 0.6 - 0.65 DQS output access time from CK/CK - 0.5 + 0.5 tCH CK high-level width 0.45 tCL CK low-level width tCK Clock cycle time tDH DQ and DM input hold time 0.4 tDS DQ and DM input setup time tIPW tAC tDQSCK tDQSQ DQS-DQ skew (DQS & associated DQ signals) TSOP Package + 0.4 + 0.4 ns 1-4 BGA Package + 0.4 + 0.4 ns 1-4 tHP Minimum half clk period for any given cycle; defined by clk high (t CH) or clk low (t C L) time min (t CL , tCH) min (tCL , tCH) tCK 1-4 tQH Data output hold time from DQS tHP - tQHS tHP - tQHS tCK 1-4 tQ H S Data hold Skew Factor TSOP Package 0.5 0.5 tCK 1-4 BGA Package 0.5 0.5 tCK 1-4 1.28 tCK 1-4 tDQSS Write command to 1st DQS latching transition 0.72 tDQSH DQS input high pulse width (write cycle) 0.35 0.35 tCK 1-4 tDQSL DQS input low pulse width (write cycle) 0.35 0.35 tCK 1-4 tDSS DQS falling edge to CK setup time (write cycle) 0.2 0.2 tCK 1-4 tDSH DQS falling edge hold time from CK (write cycle) 0.2 0.2 tCK 1-4 tM R D Mode register set command cycle time 2 2 tCK 1-4 tWPRES Write preamble setup time 0 0 ns 1-4, 7 tWPST Write postamble 0.40 tCK 1-4, 6 tWPRE Write preamble 0.25 0.25 tCK 1-4 tIH Address and control input hold time (fast slew rate) 0.6 0.6 ns 2-4, 9, 11, 12 tIS Address and control input setup time (fast slew rate) 0.6 0.6 ns 2-4, 9, 11, 12 tIH Address and control input hold time (slow slew rate) 0.7 0.7 ns 2-4, 10, 11, 12, 14 REV 1.3 06/2003 1.28 0.60 0.72 0.40 0.60 60 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Electrical Characteristics & AC Timing - Absolute Specifications (0 C T A 70 C; VDDQ = +2.6V 0.1V; VDD = 2.6V 0.1V, See AC Characteristics) (Part 2 of 2) Symbol DDR400 (-5) Parameter Min Address and control input setup time (slow slew rate) 0.7 tRPRE Read preamble 0.9 tRPST Read postamble tRAS Active to Precharge command tRC Active to Active/Auto-refresh command period 55 tIS DDR400 (-5T) Max Min Unit Notes ns 2-4, 10, 11, 12, 14 1.1 tCK 1-4 Max 0.7 1.1 0.9 0.40 0.60 0.40 0.60 tCK 1-4 40 120,000 40 120,000 ns 1-4 55 ns 1-4 tR F C Auto-refresh to Active/Auto-refresh command period 70 70 ns 1-4 tRCD Active to Read or Write delay 15 15 ns 1-4 tRAP Active to Read Command with Autoprecharge min (t RCD, tRAS ) min (t RCD, tRAS ) ns 1-4 tRP Precharge command period 15 15 ns 1-4 tRRD Active bank A to Active bank B command 10 10 ns 1-4 tWR Write recovery time 15 15 ns 1-4 tDAL Auto precharge write recovery + precharge time (t WR /tCK ) + (t RP/tCK ) (t WR /tCK ) + (t RP /tCK ) tCK 1-4, 13 tW T R Internal write to read command delay 2 2 tCK 1-4 tPDEX Power down exit time 5 5 ns 1-4 tXSNR Exit self-refresh to non-read command 75 75 ns 1-4 tXSRD Exit self-refresh to read command 200 200 tCK 1-4 tREFI Average Periodic Refresh Interval s 1-4, 8 REV 1.3 06/2003 7.8 7.8 61 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Electrical Characteristics & AC Timing - Absolute Specifications Notes 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Input slew rate = 1V/ns. The CK/CK input reference level (for timing reference to CK/CK) is the point at which CK and CK cross; the input reference level for signals other than CK/CK is VREF . Inputs are not recognized as valid until VREF stabilizes. The Output timing reference level, as measured at the timing reference point indicated in AC Characteristics (Note 3) is VTT . tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referred to a specific voltage level, but specify when the device is no longer driving (HZ), or begins driving (LZ). The maximum limit for this parameter is not a device limit. The device operates with a greater value for this parameter, but system performance (bus turnaround) degrades accordingly. The specific requirement is that DQS be valid (high, low, or some point on a valid transition) on or before this CK edge. A valid transition is defined as monotonic and meeting the input slew rate specifications of the device. When no writes were previously in progress on the bus, DQS will be transitioning from Hi-Z to logic LOW. If a previous write was in progress, DQS could be HIGH, LOW, or transitioning from high to low at this time, depending on tDQSS. A maximum of eight Autorefresh commands can be posted to any given DDR SDRAM device. For command/address input slew rate 1.0V/ns. Slew rate is measured between V OH (AC) and VOL (AC). For command/address input slew rate 0.5V/ns and < 1.0V/ns. Slew rate is measured between VOH (AC) and VOL (AC). CK/CK slew rates are 1.0V/ns. These parameters guarantee device timing, but they are not necessarily tested on each device, and they may be guaranteed by design or tester characterization. For each of the terms in parentheses, if not already an integer, round to the next highest integer. tCK is equal to the actual system clock cycle time. For example, for DDR266B at CL = 2.5, tDAL = (15ns/7.5ns) + (20ns/7.5ns) = 2+ 3 = 5. REV 1.3 06/2003 62 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM 14. An input setup and hold time derating table is used to increase tIS and tIH in the case where the input slew rate is below 0.5 V/ns. Input Slew Rate delta (t IS ) delta (tIH ) Unit Notes 0.5 V/ns 0 0 ps 1,2 0.4 V/ns +50 0 ps 1,2 0.3 V/ns +100 0 ps 1,2 1. Input slew rate is based on the lesser of the slew rates determined by either V IH (AC) to V IL (AC) or V IH (DC) to V IL (DC), similarly for rising transitions. 2. These derating parameters may be guaranteed by design or tester characterization and are not necessarily tested on each device. 15. An input setup and hold time derating table is used to increase tDS and tDH in the case where the I/O slew rate is below 0.5 V/ns. Input Slew Rate delta (t D S) delta (t DH ) Unit Notes 0.5 V/ns 0 0 ps 1,2 0.4 V/ns +75 +75 ps 1,2 0.3 V/ns +150 +150 ps 1,2 1. I/O slew rate is based on the lesser of the slew rates determined by either V IH (AC) to V IL (AC) or V IH (DC) to V IL (DC), similarly for rising transitions. 2. These derating parameters may be guaranteed by design or tester characterization and are not necessarily tested on each device. 16. An I/O Delta Rise, Fall Derating table is used to increase tDS and tDH in the case where DQ, DM, and DQS slew rates differ. Input Slew Rate delta (t D S) delta (t DH ) Unit Notes 0.0 V/ns 0 0 ps 1,2,3,4 0.25 V/ns +50 +50 ps 1,2,3,4 0.5 V/ns +100 +100 ps 1,2,3,4 1. Input slew rate is based on the lesser of the slew rates determined by either V IH (AC) to V IL (AC) or V IH (DC) to V IL (DC), similarly for rising transitions. 2. Input slew rate is based on the larger of AC to AC delta rise, fall rate and DC to DC delta rise, fall rate. 3. The delta rise, fall rate is calculated as: [1/(slew rate 1)] - [1/(slew rate 2)] For example: slew rate 1 = 0.5 V/ns; slew rate 2 = 0.4 V/ns Delta rise, fall = (1/0.5) - (1/0.4) [ns/V] = -0.5 ns/V Using the table above, this would result in an increase in t DS and t DH of 100 ps. 4. These derating parameters may be guaranteed by design or tester characterization and are not necessarily tested on each device. REV 1.3 06/2003 63 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Package Dimensions (400mil; 66 lead; Thin Small Outline Package) Detail A 11 .76 0.20 10.16 . 0.13 22.22 0.10 Lead #1 Seating Plane 0.10 0.65 Basic 0.30 + 0.03 - 0.08 0.71REF 1.20 Max Detail A 0.25 Basic Gage Plane 0.5 0.1 0.05 Min REV 1.3 06/2003 64 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Package Dimensions (60 balls; 0.8mmx1.0mm Pitch; CSP Package) 8.0 0.80 13.0 0.50 1.00 0.80 1.0 Dia. 0.45 0.35 1.60 1.15 Note : All dimensions are typical unless otherwise stated. Unit : Millimeters REV 1.3 06/2003 65 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. NT5DS64M4BT NT5DS32M8BT NT5DS16M16BT NT5DS64M4BF NT5DS32M8BF NT5DS16M16BF NT5DS64M4BS NT5DS32M8BS NT5DS16M16BS NT5DS64M4BG NT5DS32M8BG NT5DS16M16BG 256Mb DDR SDRAM Revision Log Rev Date Modification 0.1 01/2003 Preliminary Release 0.2 02/2003 Updated tQHS from 0.55ns to 0.5ns in Electrical Characteristics & AC Timing Table Updated IDD values in IDD Specifications and Conditions Table Removed CL2 support 1.0 03/2003 Added DDR400B (-5T) speed grade Official Release 1.1 04/2003 Fixed typo for tWTR in Electrical Characteristics & AC Timing Table 1.2 05/2003 Added Lead-free and Halogen-free component part numbers 1.3 06/2003 Fixed various typos regarding CAS Latency 3 support 1.4 10/2003 Removed CAS Latency 2.5 support REV 1.3 06/2003 66 (c) NANYA TECHNOLOGY CORP. All rights reserved. NANYA TECHNOLOGY CORP. reserves the right to change Products and Specifications without notice. (R) Nanya Technology Corporation. All rights reserved. Printed in Taiwan, R.O.C. June 2002 The following are trademarks of NANYA TECHNOLOGY CORPORATION in R.O.C, or other countries, or both. NANYA NANYA logo Other company, product and service names may be trademarks or service marks of others. NANYA TECHNOLOGY CORPORATION (NTC) reserves the right to make changes without notice. NTC warrants performance of its semiconductor products and related software to the specifications applicable at the time of sale in accordance with NTC's standard warranty. Testing and other quality control techniques are utilize to the extent NTC deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. Certain applications using semiconductor products may involve potential risks of death, personal injury, or severe property or environmental damage ("Critical Applications"). NTC SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, INTEND, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT APPLICATIONS, DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. Inclusion of NTC products in such applications is understood to be fully at the risk of the customer. Use of NTC products in such applications requires the written approval of an appropriate NTC officer. Question concerning potential risk applications should be directed to NTC through a local sales office. In order to minimize risks associated with the customer's applications, adequate design and operating safeguards should be provided by customer to minimize the inherent or procedural hazards. NTC assumes no liability of applications assistance, customer product design, software performance, or infringement of patents or services described herein. Nor does NTC warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of NTC covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. NANYA TECHNOLOGY CORPORATION HWA YA Technology Park 669, FU HSING 3rd Rd., Kueishan, Taoyuan, Taiwan, R.O.C. The NANYA TECHNOLOGY CORPORATION home page can be found at http:\\www.nanya.com