COMPUTING
This six-slot, 40G ATCA shelf
is ideal for both traditional
telecom and enterprise
environments
6-slot, 7U, 19” form factor
AC & DC power input options
All redundant eld replaceable
units (FRUs) of the shelf
infrastructure included
Integrated Telco Alarm
functionality
Front & rear cable management
CP-TA B.4 compliant thermal
performance
Up to 350 Watts/blade power
distribution
RoHS (6 of 6) compliant
Designed for NEBS/ETSI
compliance (DC variants only)
The Artesyn Embedded Technologies AXP640 AdvancedTCA® shelf is specically designed to
address carrier-grade requirements desired by the telecommunications industry as well as high
availability enterprise environments. Application examples include wireless infrastructure, packetized
voice, wireline data, video distribution and cable network head-end devices. Highly integrated and
veried hardware and software components, reduced development costs and accelerating
time-to-market allow customers to focus their development resources on critical, differentiating
features that provide a competitive advantage.
The heart of the AdvancedTCA (ATCA®) shelf is the 40G backplane. This allows for 40Gbps
communication across the PICMG® 3.1 compliant fabric interface. Using this technology, it is
possible to upgrade to 40GbE capable switch and payload blades without replacing the shelf
infrastructure. ATCA 40G technology is becoming increasingly important as dataplane applications
start migrating to ATCA based platforms.
Equally important are the thermal characteristics of the AXP640 shelf. It is designed to exceed the
CP-TA B.4 thermal prole and match future enhanced thermal proles. This superior thermal
performance is achieved with a front-to-back cooling architecture and therefore is ideal for both
traditional telecommunications and enterprise environments. As processor technology advances,
thermal (heat dissipation) performance is one of the industry’s largest challenges – the AXP640
provides unmatched thermal characteristics to address this needs.
The power infrastructure of the AXP640 is designed to support AC and DC power inputs and
provides up to 350 Watts/slot.
Data Sheet
AXP640
40G AdvancedTCA Shelf
AXP640 Data Sheet
Shelf Architecture
40G Backplane
FTM
FTM
FTM
Fan Tray Module
SAM - BSAM - A
Shelf Management and
Alarm Module
48-A 48-A
Power Distribution PCB
48-A
PSU/PEM
48-A
PSU
48-A
PSU
48-A
PSU/PEM
AC/DC inlet
AC/DC inlet
AXP640 Data Sheet
Shelf Overview
ENCLOSURE
Six (6) slots for 8U blades (horizontal)
Six (6) slots for 8U rear transition modules (RTMs) (horizontal)
40G backplane
Front to rear cooling architecture
ESD and earth grounding points
ENCLOSURE DIMENSIONS
Height – 309.9 mm
Width – 448.2 mm
Depth – 492.3 mm
Depth – 550.0 mm (with cable tray)
Note – Dimension gures do not include mounting ears and cable
trays unless specically noted
PRODUCT WEIGHT
AXP640-DC2 – 22 kg/49 lbs
AXP640-AC2-220VAC – 22.5 kg/50 lbs
AXP640-AC2-110VAC – 26.5 kg/58.5 lbs
OPERATING ENVIRONMENT
Operating temperature range (DC): -5 °C to 55 °C @ 90%
non-condensing humidity
Operating temperature range (AC): -5 °C to 50 °C
@ 90% non-condensing humidity
Storage temperature range: -40 °C to 70 °C
@ 95% relative humidity
POWER REQUIREMENTS
AXP640-DC2 maximum: 390 Watts
AXP640-AC2-220VAC maximum: 447 Watts
AXP640-AC2-110VAC maximum: 447 Watts
BACKPLANE
Zone 1
Redundant, radial IPMI to all blade slots
Redundant, bussed -48 VDC to all blade slots
Zone 2
Dual star conguration for the base interface
(2 hub, 4 node blades)
Single star conguration for the fabric interface
(1 hub, 5 node blades)*
Dual star conguration for the fabric interface
(2 hub, 4 node blades)*
Update channel routing for all hub/node slots
Three redundant, bussed telecom clock signals to all hub/node
slots
Update channel routing
Zone 3
PICMG 3.0 dened open area, application specic
* All fabric interface congurations support 1G, 10G and 40G
operation
SHELF MANAGEMENT
N+1 redundancy architecture
Two (2) shelf management & alarm module slots
Embedded Telco Alarm functionality
POWER DISTRIBUTION
2N redundancy architecture
AXP640-DC2 – Two (2) power entry module (PEM) slots
AXP640-AC2-220VAC – Two (2) power supply unit (PSU) slots
AXP640-AC2-110VAC – Four (4) PSU slots
COOLING
N+1 redundancy architecture
Front-to-back cooling architecture
THREE (3) BOTTOM/REAR FAN TRAY MODULE SLOTS
RELEVANT STANDARDS
PICMG 3.0 (form factor, IPMI, base interface, hot swap, RTM)
PICMG 3.1, Options 1 and 9 (1G, 10G operation)
PICMG 3.1 R2 (40G operation) – Future, pending specication
release.
CP-TA B.4
AXP640 Data Sheet
Shelf Layout
FRONT (TOP TO BOTTOM)
Six (6) horizontal, 8U blade slots
Front cable management system
Two (2) vertical, Shelf Management Modules slots
Four (4) power module slots (AC/DC)
Air inlet area
REAR (TOP TO BOTTOM)
Six (6) horizontal, 8U RTM slots
Rear cable management system
Telco Alarm interface (DB-15)
Four (4) AC input receptacles
Three (3) fan tray module slots
Two (2) sets of DC input lugs
FRONT VIEW
AXP640 Data Sheet
Rear VIEW
Shelf Management
The purpose of shelf management, as dened by the PICMG 3.0
standard, is to assure proper operation of AdvancedTCA blades
and other components within the shelf. The shelf management
module continually monitors all low-level, hardware functionality
(inventory, sensor, status data, etc.) and reports status to the
system manager. It also provides control access to these attributes.
Management access to this information is provided via local
console and Ethernet interfaces as well as the Service Availability™
Forum (SA Forum) dened HPI interface. Each blade and major
shelf component has an Intelligent Platform Management Controller
(IPMC) that is responsible for providing this information to the shelf
management module. The AXP640 shelf provides redundant shelf
management functionality utilizing an active/standby architecture. In
addition, the Telco Alarm functionality is integrated into the same
module to maximize critical real estate within the shelf and is also
redundant. Visual indicators, as well as physical interfaces, are
provided for direct front panel access.
PANEL ACCESS & INTERFACES
One (1) RS-232 console, RJ-45
One (1) 10/100BaseT Ethernet, RJ-45
TELCO ALARM STATUS INDICATORS
Critical/major/minor
SHELF MANAGER LED STATUS INDICATORS
In service (IS)
Out of service (OOS)
Hot swap (H/S)
AXP640 Data Sheet
Fan Tray Module
The AXP640 shelf provides fault-tolerant cooling to all Front/RTM
slots as well as the shelf management and power entry module
slots. The AXP640 utilizes an N+1 cooling architecture and is
implemented using three lower/rear fan tray modules.
GENERAL CHARACTERISTICS
CP-TA B.4 compliant cooling architecture
Front-to-back cooling architecture
Front blade cooling capacity: 40 cubic feet per minute (CFM) at
55 °C
RTM cooling capacity: 5 CFM at 55 °C
Automatic fan speed control
LED STATUS INDICATORS
Combined in-service, out-of-service (IS/OOS) LED (Green/Red)
Power Entry Module (PEM)
Power conditioning for the DC variant of the AXP640 shelf is
provided by a pair of redundant PEMs. They provide power to the
backplane on the redundant -48 VDC power rails for blades, RTMs
and other shelf components.
GENERAL CHARACTERISTICS
Input voltage range (-40 VDC to -72 VDC)
60 Amp, single feed PEM with breaker switch
Power distribution capable of delivering up to
350 Watts/slot
EMI conductive ltering
Breaker trip detection
Transient voltage suppression
LED STATUS INDICATORS
Combined in-service, out-of-service (IS/OOS)
LED (Green/Red)
Power Supply Unit (PSU)
Power conditioning for the AC variants of the AXP640 shelf is
provided by two or four AC PSUs. Standard AC receptacles are
provided for simply installation, the PSU output provides DC power
to the backplane on the redundant -48 VDC power rails for blades,
RTMs and other shelf components. For 220 VAC environments,
qty=2, AC PSUs are installed; for 110 VAC environments qty=4, AC
PSUs are installed.
GENERAL CHARACTERISTICS
Input voltage range (180 – 264 VAC or
90 – 140 VAC ) auto detect
Input current 16 Amp maximum
Frequency 43 to 63 Hz
Power factor 0.97 (typical)
Power distribution capable of delivering up to
350 Watts/slot
Inputs fused at 25 Amp
Transient voltage suppression
LED STATUS INDICATORS
In service (IS)
Out of service (OOS)
AXP640 Data Sheet
Ordering Information
Marketing Number Description
Shelf Products
AXP640-DC2 ATCA shelf - 6 slot, 19”, 7U, 40G, PP SHMM - Redundant DC PEM - Silver
AXP640-DC2-B ATCA shelf - 6 slot, 19”, 7U, 40G, PP SHMM - Redundant DC PEM - Black
AXP640-AC2-220VAC ATCA shelf - 6 slot, 19”, 7U, 40G, PP SHMM - Redundant AC PSU (220 VAC) - Silver
AXP640-AC2-220VAC-B ATCA shelf - 6 slot, 19”, 7U, 40G, PP SHMM - Redundant AC PSU (220 VAC) - Black
AXP640-AC2-110VAC ATCA shelf - 6 slot, 19”, 7U, 40G, PP SHMM - Redundant AC PSU (110 VAC) - Silver
AXP640-AC2-110VAC-B ATCA shelf - 6 slot, 19”, 7U, 40G, PP SHMM - Redundant AC PSU (110 VAC) - Black
Accessory & FRU Products
AXP-F-FILL-PANEL Blank ller panel, AXP1620, AXP1440, AXP141x, AXP640, C2000 - Front - Silver
AXP-R-FILL-PANEL Blank ller panel, AXP1620, AXP1440, AXP141x, AXP640, C2000 - Rear - Silver
PEM640 DC power entry module for the AXP640
PSU640 AC power supply unit for the AXP640
FTM640 Fan tray module for AXP640 - Silver
FTM640-B Fan tray module for AXP640 - Black
SAM640 Shelf manager module for the AXP640 - Silver
SAM640-B Shelf manager module for the AXP640 - Black
RAF640-SET Replaceable air lters (set of two) for the AXP640
BEZEL640-B Front bezel for the AXP640 - Black
AXP640-RKMT-FR-19 Front mounting brackets for the AXP640 for a 19” rack (set of two)
AXP640-RKMT-FR-23 Front mounting brackets for the AXP640 for a 23’’ rack (set of two)
AXP640-RKMT-MID-19 Mid-mounting brackets for the AXP640 for a 19” rack (set of two)
AXP640-RKMT-MID-23 Mid-mounting brackets for the AXP640 for a 23” rack (set of two)
CABLE/RJ45/DSUB/6E Adapter cable - RJ45 to DSUB9 female (needed to connect e.g. a laptop to serial interface of ATCA-7107) (RoHS 6/6)
AC-PC-15A-AUS-ZEL AXP640 - AC power cord, 15 amps, 250 volts, Australia & New Zealand connector
AC-PC-16A-EU AC power cord, 16 amps, 250 volts, EU connector
AC-PC-20A-PIGTAIL AXP640 - AC power cord, right angle, 20 amps, 250 volts, pigtail
AC-PC-20A-US AC power cord, 20 amps, 125 volts, US & Canada connector
AC-PC-13A-UK AC POWER CORD, 13 AMPS, 250 VOLTS, UK CONNECTOR
www.artesyn.com
WORLDWIDE OFFICES
United States +1 888 412 7832 China +86 400 8888 183
Germany +49 89 9608 2552 Japan +81 3 5403 2730
Hong Kong +852 2176 3540 Korea +82 2 6004 3268
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. AdvancedTCA and ATCA are trademarks of PICMG.
All other names and logos referred to are trade names, trademarks, or registered trademarks of their
respective owners. © 2016 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and
conditions, please visit www.artesyn.com/legal.
AXP640 Data Sheet
AXP640-DS16Nov2016
SOLUTION SERVICES
Artesyn Embedded Technologies provides a portfolio of solution services optimized to meet your needs throughout the product lifecycle. Design services help
speed time-to-market. Deployment services include global 24x7 technical support. Renewal services enable product longevity and technology refresh.
Regulatory Compliance
Item Description
Designed to comply with NEBS
(DC variants only)
Telcordia GR-63-CORE, NEBS Physical Protection, Level 3
Telcordia GR-1089-CORE, Electromagnetic Compatibility and Electrical Safety — Generic Criteria for Network
Telecommunications Equipment. Level 3, Equipment Type 2
Designed to comply with ETSI
(DC variants only)
ETSI Storage, ETS 300 019-2-1, Class 1.2 equipment, Weatherprotected, not Temperature Controlled Storage
Locations
ETSI Transportation, ETS 300 019-1-2, Class 2.3 equipment, Public Transportation
ETSI Operation, ETS 300 019-1-3, Class 3.1(E) equipment, Partly Temperature Controlled Locations
ETSI EN 300-132-2 Environmental Engineering (EE); Power supply interface at the input to telecommunications
equipment; Part 2: Operated by direct current (dc)
ETS-300-753, Equipment Engineering (EE); Acoustic noise emitted by telecommunications equipment
EMC
ETSI EN 300 386 Electromagnetic compatibility and Radio spectrum Matters (ERM); telecommunication network
equipment; ElectroMagnetic Compatibility (EMC) requirements, Telecommunication equipment room (attended)
FCC 47 CFR Part 15 Subpart B (US), Class A
ECISPR 22, Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology
Equipment
AS/NZS CISPR 22 (Australia/New Zealand), Limits and Methods of Measurement of Radio Disturbance Characteristics
of Information Technology Equipment
VCCI Class A (Japan), Voluntary Control Council for Interference by Information Technology Equipment
Industry Canada ICES-003 Class A
Safety Compliance to UL/CSA 60950-1, EN 60950-1 and IEC 60950-1 CB Scheme. Marked with U.S. NRTL, Canadian Safety
and CE Mark.
RoHS/WEEE compliance
DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL on the restriction of the use of
certain hazardous substances in electrical and electronic equipment (RoHS)
DIRECTIVE 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL on waste electrical and electronic
equipment (WEEE)
CE Conformity Directive 2004/108/EC, Directive 2006/95/EC