AC axial fan W4D350-CA06-14 straight blades (A series) Wall ring with guard grille ebm-papst Mulfingen GmbH & Co. KG Bachmuhle 2 * D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership * Headquarters Mulfingen County court Stuttgart * HRA 590344 General partner Elektrobau Mulfingen GmbH * Headquarters Mulfingen County court Stuttgart * HRB 590142 Nominal data Type W4D350-CA06-14 Motor M4D068-EC Phase Nominal voltage VAC Connection Frequency Hz Type of data definition Valid for approval / standard 3~ 3~ 3~ 3~ 230 230 400 400 Y Y 50 60 50 60 fa fa fa fa CE CE CE CE Speed min-1 1420 1620 1420 1620 Power input W 145 190 145 190 Current draw A 0.68 0.62 0.39 0.36 Max. back pressure Pa 150 150 150 150 Min. ambient temperature C -25 -25 -25 -25 Max. ambient temperature C 50 50 50 50 ml = Max. load * me = Max. efficiency * fa = Running at free air * cs = Customer specs * cu = Customer unit Subject to alterations Data according to ErP directive Actual Request 2013 Request 2015 28.5 24.5 28.5 40 36 40 Installation category A Overall efficiency es Efficiency category Static Efficiency grade N Variable speed drive No Power input Pe kW 0.15 Specific ratio* 1.00 Air flow qv m/h 2015 Pressure increase pfs Pa 75 Speed n min-1 1390 * Specific ratio = 1 + pfs / 100 000 Pa Data definition with optimum efficiency. Item no. 13169-5-9980 * Revision 79414 * Release 2013-02-26 * Page 1 / 6 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com AC axial fan W4D350-CA06-14 straight blades (A series) Wall ring with guard grille Technical features Mass 5.9 kg Size 350 mm Surface of rotor Coated in black Material of blades Sheet steel, coated in black Material of wall ring Sheet steel, pre-galvanised and coated in black plastic (RAL 9005) Material of guard grille Steel, coated in black plastic (RAL9005) Number of blades 5 Direction of air flow "V" Direction of rotation Counter-clockwise, seen on rotor Type of protection IP 44; Depending on installation and position as per EN 60034-1 Insulation class "B" Humidity class F1-2 Max. permissible ambient motor temp. (transp./ storage) + 80 C Min. permissible ambient motor temp. (transp./storage) - 40 C Mounting position Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharge holes Rotor-side Operation mode S1 Motor bearing Ball bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) brought out Cable exit Lateral Protection class I (if protective earth is connected by customer) Product conforming to standard EN 60335-1; CE Approval UL 1004-1 Item no. 13169-5-9980 * Revision 79414 * Release 2013-02-26 * Page 2 / 6 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com W4D350-CA06-14 AC axial fan straight blades (A series) Wall ring with guard grille Product drawing 1 Direction of air flow "V" 2 Connecting cable AWG 20, 9x brass lead tips crimped Item no. 13169-5-9980 * Revision 79414 * Release 2013-02-26 * Page 3 / 6 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com W4D350-CA06-14 AC axial fan straight blades (A series) Wall ring with guard grille Connection screen Three-phase motor Y Star connection Delta connection L1 = U1 = black 1 L2 = V1 = black 2 L3 = W1 = black 3 V2 = black4 U2 = black5 W2 = black6 TOP (Temperature monitor) 2x grey PE green / yellow Item no. 13169-5-9980 * Revision 79414 * Release 2013-02-26 * Page 4 / 6 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com AC axial fan W4D350-CA06-14 straight blades (A series) Wall ring with guard grille Charts: Air flow 50 Hz Druck p f s[Pa]fur Rho=1,2kg/m^3 250 0 200 400 600 800 qv[cfm] 1.000 1.200 1.400 1.600 1.800 1 240 0,95 230 0,9 220 210 0,85 200 0,8 190 0,75 180 0,7 170 160 0,65 150 0,6 p fs_E[IN H2O] pf s[Pa] 140 0,55 130 Measurement: LU-64797 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,5 120 0,45 110 4 100 0,4 90 0,35 80 0,3 3 70 0,25 60 50 0,2 2 40 0,15 30 0,1 20 0 ] [Pa pf s 10 1 0 200 400 600 800 1.000 1.200 1.400 1.600 1.800 2.000 2.200 2.400 2.600 2.800 3.000 qv[m^3/h] 0,05 0 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 400 50 1420 128 0.39 2870 0 2 400 50 1405 141 0.40 2535 40 3 400 50 1395 150 0.41 2170 70 4 400 50 1385 158 0.41 1500 100 U = Supply voltage * f = Frequency * n = Speed * Pe = Power input * I = Current draw * qv = Air flow * pfs = Pressure increase Item no. 13169-5-9980 * Revision 79414 * Release 2013-02-26 * Page 5 / 6 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com AC axial fan W4D350-CA06-14 straight blades (A series) Wall ring with guard grille Charts: Air flow 60 Hz Druck p f s[Pa]fur Rho=1,2kg/m^3 300 0 200 400 600 qv[cfm] 1.000 1.200 800 1.400 1.600 1.800 2.000 290 1,15 280 1,1 270 260 1,05 250 1 240 0,95 230 0,9 220 210 0,85 200 0,8 190 0,75 180 p fs_E[IN H2O] 0,7 170 pf s[Pa] 1,2 160 0,65 150 0,6 140 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,55 130 4 120 0,5 0,45 110 100 0,4 90 0,35 3 80 0,3 70 0,25 60 50 0,2 2 40 0,15 30 0,1 20 0,05 ] [Pa pf s 10 0 Measurement: LU-64798 1 0 500 1.000 1.500 2.000 qv[m^3/h] 2.500 3.000 3.500 0 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 400 60 1620 169 0.36 3280 0 2 400 60 1605 185 0.36 2985 40 3 400 60 1580 202 0.38 2580 80 4 400 60 1560 217 0.39 1855 120 U = Supply voltage * f = Frequency * n = Speed * Pe = Power input * I = Current draw * qv = Air flow * pfs = Pressure increase Item no. 13169-5-9980 * Revision 79414 * Release 2013-02-26 * Page 6 / 6 ebm-papst Mulfingen GmbH & Co. KG * Bachmuhle 2 * D-74673 Mulfingen * Phone +49 (0) 7938 81-0 * Fax +49 (0) 7938 81-110 * info1@de.ebmpapst.com * www.ebmpapst.com