1
Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
D4SL-N
/
D4SL-NSK10-LK
@
World's smallest Class 6-contact Guard Lock
Safety-door Switch
<Guard Lock Safety-door Switch D4SL-N>
Wiring time is reduced with two types of wiring
methods capable of one-touch attachment and
removal.
A wide variety of built-in switches can be used for
various devices.
(4-, 5-, and 6-contact models are available)
Key holding force of 1,300 N.
It is possible to change the key insertion point
without detaching the head.
Drive solenoids directly from the Controller.
<Slide Key D4SL-NSK10-LK@>
Lockout Key to prevent workers from becoming
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch
can be easily mounted on 40 × 40 mm aluminum
frames.
The plastic material makes the Slide Key suitable
for lightweight doors.
Terminal
Block Type Connector Type
Guard Lock Safety-door Switch
Slide Key
Be sure to read the “Safety Precautions
on page 22.
Scan the 2D codes using the smartphone to see the D4SL-N promotional videos.
Reduction in time and effort Safe access application
D4SL-N / D4SL-NSK10-LK@
2
Model Number Structure
Model Number Legend
(1) Conduit Size
(2) Built-in Switch
(3) Head Material
(4) Door Lock and Release
(5) Indicator
(6) Release Key Type
(7) Connection Method
*1. M20, includes M20-to-1/2-14NPT conversion adapter.
*2. Connector cables are not included with the connector type and are to be purchased separately.
D4SL-N@@@@-@@@
(7)
Switch (Standard type)
(6)(5)(4)(3)(2)(1)
Contact Model Conduit Size
4-contact Model
5-contact Model
6-contact Model
2: G1/2
3: 1/2-14NPT *1
4: M20
Contact Model Built-in Switch
4-contact Model
Door monitor and Lock monitor are connected in series
internally.
A: 1NC/1NO + 1NC/1NO
B: 1NC/1NO + 2NC
C: 2NC + 1NC/1NO
D: 2NC + 2NC
Door monitor and Lock monitor are NOT connected in
series internally.
S: 1NC/1NO + 1NC/1NO
T: 1NC/1NO + 2NC
U: 2NC + 1NC/1NO
V: 2NC + 2NC
5-contact Model
E: 2NC/1NO + 1NC/1NO
F: 2NC/1NO + 2NC
G: 3NC + 1NC/1NO
H: 3NC + 2NC
6-contact Model
N: 2NC/1NO + 2NC/1NO
P: 2NC/1NO + 3NC
Q: 3NC + 2NC/1NO
R: 3NC + 3NC
Contact Model Head Material
4-contact Model F: Resin
5-contact Model
6-contact Model F: Resin
D: Metal
Common
Common
Contact Model Door Lock and Release
4-contact Model
5-contact Model
6-contact Model
A: Mechanical lock/24VDC solenoid release
G: 24VDC solenoid lock/mechanical release
Contact Model Indicator
4-contact Model : None
5-contact Model
6-contact Model D: 24VDC (orange LED indicator)
Contact Model Release Key Type
4-contact Model : Standard release key (metal)
5-contact Model
6-contact Model
: Standard release key (metal)
4: Special release key (resin)
(Note:Release keys are provided.)
Contact Model Connection Method
4-contact Model
5-contact Model
6-contact Model
: Terminal block
N: Connector *2
Common
Common
Common
Common
(2) Key Type
: No cushion rubber
G: Cushion rubber
S: No cushion rubber, short type
(1) Operation Key Type
1: Horizontal mounting
2: Vertical mounting
3: Adjustable mounting (horizontal)
5: Adjustable mounting (horizontal/vertical)
D4SL-NK@@
(1) (2)
Operation key
(1) Inner Lever
Blank: No inner lever
H: With inner lever
Slide key D4SL-NSK10-LK@-@
(1) (2)
(2) Lockout key Type
Lock out key can be created up to 30 types.
Specify keys in order starting from 01.
Blank: 01
02 to 30: 02 to 30
D4SL-N / D4SL-NSK10-LK@
3
Ordering Information
List of Models
Note: The recommended models for equipment and machinery being exported to Europe are those with an M20 conduit sizes, and for North
America, the recommended models are those with a 1/2-14NPT conduit sizes.
Release
Key Type Wiring
method
Solenoid voltage/
Indicator Lock and
release type
Contact configuration
(door open/closed detection switch
and lock monitor switch contacts)
Conduit
size
(See Note.) Model
Standard
(metal)
Connector
24VDC
(Orange)
Mechanical lock
Solenoid release
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FA-DN
1/2-14NPT D4SL-N3@FA-DN
M20 D4SL-N4@FA-DN
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FA-DN
1/2-14NPT D4SL-N3@FA-DN
M20 D4SL-N4@FA-DN
24VDC
(without indicator)
4-contact Model
Insert the built-in switch (A, B, C, D, S,
T, U or V) into the blank @.
G1/2 D4SL-N2@FA-N
1/2-14NPT D4SL-N3@FA-N
M20 D4SL-N4@FA-N
Terminal
block
24VDC
(Orange)
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FA-D
1/2-14NPT D4SL-N3@FA-D
M20 D4SL-N4@FA-D
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FA-D
1/2-14NPT D4SL-N3@FA-D
M20 D4SL-N4@FA-D
24VDC
(without indicator)
4-contact Model
Insert the built-in switch (A, B, C, D, S,
T, U or V) into the blank @.
G1/2 D4SL-N2@FA
1/2-14NPT D4SL-N3@FA
M20 D4SL-N4@FA
Connector
24VDC
(Orange)
Solenoid lock
Mechanical
release
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FG-DN
1/2-14NPT D4SL-N3@FG-DN
M20 D4SL-N4@FG-DN
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FG-DN
1/2-14NPT D4SL-N3@FG-DN
M20 D4SL-N4@FG-DN
24VDC
(without indicator)
4-contact Model
Insert the built-in switch (A, B, C, D, S,
T, U or V) into the blank @.
G1/2 D4SL-N2@FG-N
1/2-14NPT D4SL-N3@FG-N
M20 D4SL-N4@FG-N
Terminal
block
24VDC
(Orange)
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FG-D
1/2-14NPT D4SL-N3@FG-D
M20 D4SL-N4@FG-D
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FG-D
1/2-14NPT D4SL-N3@FG-D
M20 D4SL-N4@FG-D
24VDC
(without indicator)
4-contact Model
Insert the built-in switch (A, B, C, D, S,
T, U or V) into the blank @.
G1/2 D4SL-N2@FG
1/2-14NPT D4SL-N3@FG
M20 D4SL-N4@FG
D4SL-N / D4SL-NSK10-LK@
4
Note: The recommended models for equipment and machinery being exported to Europe are those with an M20 conduit sizes, and for North
America, the recommended models are those with a 1/2-14NPT conduit sizes.
Release
Key Type Wiring
method
Solenoid voltage/
Indicator Lock and
release type
Contact configuration
(door open/closed detection switch
and lock monitor switch contacts)
Conduit size
(See Note.) Model
Special
(resin)
Connector
24VDC
(Orange)
Mechanical lock
Solenoid release
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FA-D4N
1/2-14NPT D4SL-N3@FA-D4N
M20 D4SL-N4@FA-D4N
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FA-D4N
1/2-14NPT D4SL-N3@FA-D4N
M20 D4SL-N4@FA-D4N
Terminal
block
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FA-D4
1/2-14NPT D4SL-N3@FA-D4
M20 D4SL-N4@FA-D4
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FA-D4
1/2-14NPT D4SL-N3@FA-D4
M20 D4SL-N4@FA-D4
Connector
Solenoid lock
Mechanical
release
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FG-D4N
1/2-14NPT D4SL-N3@FG-D4N
M20 D4SL-N4@FG-D4N
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FG-D4N
1/2-14NPT D4SL-N3@FG-D4N
M20 D4SL-N4@FG-D4N
Terminal
block
6-contact Model
Insert the built-in switch (N, P, Q or R)
into the blank @.
G1/2 D4SL-N2@FG-D4
1/2-14NPT D4SL-N3@FG-D4
M20 D4SL-N4@FG-D4
5-contact Model
Insert the built-in switch (E, F, G or H)
into the blank @.
G1/2 D4SL-N2@FG-D4
1/2-14NPT D4SL-N3@FG-D4
M20 D4SL-N4@FG-D4
D4SL-N / D4SL-NSK10-LK@
5
Operation Keys
Connector Cables
Type Model
Horizontal mounting D4SL-NK1
Horizontal mounting
(Short) D4SL-NK1S
Horizontal mounting
(Cushion rubber) D4SL-NK1G
Vertical mounting D4SL-NK2
Vertical mounting
(Cushion rubber) D4SL-NK2G
Adjustable
(Horizontal) D4SL-NK3
Adjustable
(Horizontal/Vertical) D4SL-NK5
Cable length Model
1 m D4SL-CN1
3 m D4SL-CN3
5 m D4SL-CN5
10 m D4SL-CN10
D4SL-N / D4SL-NSK10-LK@
6
Slide Key
Note: 1. The Door Switch is not included. Select the Door Switch depending on the necessary number of contacts and the conduit size.
The contents are provided as a total set, individual contents cannot be ordered separately.
2. Perform risk assessment for the equipment in question, configure relay units and other safety circuits, and use properly.
*1. The number for the lockout key is 01.
*2. Replace the box with 02 to 30 (lockout key number). Ask your OMRON representative for delivery times.
*3. The inner lever for D4SL-NSK10 that can not be used for other products and applications.
Applicable Door Switches
D4SL-NSK10-LK
D4SL-NSK10-LKH
Type Specifications Contents Model Applicable
Door Switch
Weight: Approx. 0.6 kg
Mechanical durability:
20,000 operations min.
Slide Key: 1 (not yet mounted)
Inner Lever: None
D4SL-N mounting plate: 1
Door Switch special mounting screws: 3
D4SL-NK1 (operation key): 1
D4SL-NK1 special mounting screws: 2
Lockout keys: 2
Lockout key strap: 1
Caution labels (stickers): 2 sheets
(English and Japanese)
D4SL-NSK10-LK *1
D4SL-N
D4SL-NSK10-LK-@ *2
Weight: Approx. 0.1 kg Inner Lever: 1 D4SL-SK10H *3 ---
Weight: Approx. 0.7 kg
Mechanical durability:
20,000 operations min.
Slide Key: 1 (not yet mounted)
Inner Lever: 1
D4SL-N mounting plate: 1
Door Switch special mounting screws: 3
D4SL-NK1 (operation key): 1
D4SL-NK1 special mounting screws: 2
Lockout keys: 2
Lockout key strap: 1
Caution labels (stickers): 2 sheets
(English and Japanese)
D4SL-NSK10-LKH *1
D4SL-N
D4SL-NSK10-LKH-@ *2
+=
D4SL-ND4SL-NSK10-LK
+=
D4SL-ND4SL-NSK10-LKH
D4SL-N / D4SL-NSK10-LK@
7
Features
The lockout key prevents workers from becoming trapped without using a padlock.
Note: Using LEDs of D4SL-N enables confirming whether the door is open or closed and locked or unlocked.
D4SL-N / D4SL-NSK10-LK@
8
Structure and Nomenclature
Structure
Can be mounted
from four directions.
Two operation key holes
The switch has
a release key
on the back of
the switch as well.
The switch has an
indicator on the back
of the switch as well.
Can be mounted
from four directions.
Two operation key holes
The switch has
a release key
on the back of
the switch as well.
The switch has an
indicator on the back
of the switch as well.
4.5 dia. * 4.5 dia. *
E1 (+)
E2 ()
11
21
33
9
10
41
51
63
42
52
64
<LED>
ORANGE
1
2
3
4
5
67
8
12
22
34
for D4SL-N@N@@-D@
Note: Numbers inside the boxes are terminal
numbers printed on the product.
D4SL-@@@@-D@ Terminal Block TypeD4SL-N@@@@-D@N Connector Type
4 5 6 10321
Notched side is No. 1
13 579
106428
4.5 dia. *
4.5 dia. *
Connector/Terminal
Terminal Arrengement
* You can insert and secure a stud or
other projection in the 4.5-dia. hole to
make the installation even stronger.
For details, refer to “Switch and
Operation Key Mounting” on page 24.
D4SL-N / D4SL-NSK10-LK@
9
Operating Cycle Examples for Standard Models
D4SL-N@@@A-@ (Mechanical Lock Models)
D4SL-N@@@G-@ (Solenoid Lock Models)
Door open/closed detection and lock monitor contacts: Can be used in safety circuits because of the direct opening mechanisms.
Door open/closed detection contact: Can be used to confirm whether the key is inserted and to monitor the open/closed status of a door.
Lock monitor contact: Can be used to confirm whether power is supplied to the solenoid and to monitor whether or not a door can be opened or closed.
Note: 1. The door open/closed detection and lock monitor contact configuration depends on the model.
2. If a current is detected in the solenoid lock model, before the door is closed, the door will remain unlocked.
Be sure to supply power to the solenoid after the door is closed.
Door condition Condition 1 Condition 2 Condition 3 Turning the special
release key
Terminal No. and
Contact No. Function
Door open.
The door will lock
when the door closes.
Door closed.
The door is locked.
Door closed.
The door can be
opened.
Door closed.
No power is supplied
to the solenoid.
The door is unlocked
manually.
Solenoid ON
Door open/closed detection
and lock monitor contacts
Door open/closed detection
contact
Door open/closed detection
contact
Lock monitor contact
Lock monitor contact
Door condition Even when the door
is closed, it does not
lock until power is
supplied to the
solenoid.
Door closed.
The door is locked.
Door closed.
The door can be
opened.Terminal No. and
Contact No. Function
Solenoid ON
Door open/closed detection
and lock monitor contacts
Door open/closed detection
contact
Door open/closed detection
contact
Lock monitor contact
Lock monitor contact
Return to
condition 1
E1- 10 E2
9
42- 111 (NC)
2
52- 321 (NC)
4
21- 422 (NC)
3
31- 632 (NC)
5
33- 634 (NO)
5
41- 242 (NC)
1
61- 862 (NC)
7
63- 864 (NO)
7
The shaded areas indicate
the contact is closed and
power is supplied to the
solenoid.
E1- 10 E2
9
42- 111 (NC)
2
52- 321 (NC)
4
21- 422 (NC)
3
31- 632 (NC)
5
33- 634 (NO)
5
41- 242 (NC)
1
61- 862 (NC)
7
63- 864 (NO)
7
D4SL-N / D4SL-NSK10-LK@
10
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EMC Directive
EN ISO 14119
EN60204-1
GS-ET-19
Certified Standards
*1. Certification has been obtained for UL CSA C22.2 No. 14.
*2. Only certain models have been certified.
Certified Standard Ratings
TÜV (EN60947-5-1) CCC (GB14048.5)
Note: Use a 4 A fuse that conforms to IEC60127 as a short-circuit protection device. This fuse is not included with the switch.
*1. 11-42, 21-52, 21-22
*2. Other terminals
UL/CSA (UL508, CSA C22.2 No.14)
C150
R150
Solenoid Coil Characteristics
* A starting current is applied to the solenoid for Approx. 10 seconds.
After this, the internal circuit switches to a constant current.
Indicator
Certification body Standard File No.
TÜV SÜD EN60947-5-1 (certified direct opening) Consult your OMRON representative for details.
UL *1 UL508, CSA C22.2 No.14 E76675
CQC (CCC) GB14048.5 2012010305582059
KOSHA *2 EN60947-5-1 Consult your OMRON representative for details.
Utilization category AC-15 DC-13
Rated operating current (Ie) 1.5 A *1
1 A *2 0.22 A
Rated operating voltage (Ue) 120 V 125 V
Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC 2.5 A 15 1.5 1,800 180
Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
125 VDC 1.0 A 0.22 0.22 2828
Item 24 VDC
Rated operating voltage (100% ED) 24 VDC
Current consumption *
Power ON:
6-contact type Approx. 6.4 W at 0.26 A
4-contact/5-contact type Approx. 4.8 W at 0.2 A
Constant: Approx. 2.6 W (average) at 0.2 A (max.)
Insulation Class E (to 120°C)
Item LED type
Rated voltage 24 VDC
Current consumption Approx.10 mA
Color (LED) Orange
+10%
15%
D4SL-N / D4SL-NSK10-LK@
11
Characteristics
Note: 1. The above values are initial values.
2. The Switch contacts can be used with either standard loads or microloads.
Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads.
The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1).
Confirm that sealing properties are sufficient for the operating conditions and environment beforehand.
Although the switch box is protected from dust, oil or water penetration, do not use the D4SL in places where cutting chips, oil, water or
chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON
representative.
*3. Do not pass the 1 A, 125 VAC load through more than 3 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This figure is based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment, and reliability level.
Confirm that correct operation is possible with the actual load beforehand.
Degree of protection *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 1,000,000 operations min.
Electrical 150,000 operations min. (1 A resistance at 125 VAC) *3
Operating speed 0.05 to 1 m/s
Operating frequency 4- and 5-contact Model: 30 operations minute max.
6-contact Model: 5 operations minute max.
Direct opening force *4 60 N min. (EN60947-5-1)
Direct opening travel *4 15 mm min. (EN60947-5-1)
Holding force *5 1,300 N min.
Contact resistance 200 mΩ max.
Minimum applicable load *6 1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui) 150 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse
withstand voltage
(EN60947-5-1)
Between terminals of same polarity 1.5 kV
Between terminals of different polarity 1.5 kV
Between other terminals and
non-current carrying metallic parts 2.5 kV
Insulation resistance 100 Ω min. (at 500 VDC)
Vibration resistance Malfunction 10 to 55 Hz, 0.35 mm single amplitude
Shock resistance Malfunction 80 m/s2 min.
Destruction 1,000 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional free air thermal current (Ith) 2.5A (11-42, 21-52, 21-22)
1A (Others)
Ambient operating temperature 10 to 55°C (with no icing)
Ambient operations humidity 95% max.
Weight
Head: Resin
Approx. 290 g (Connector model)
Approx. 330 g (Terminal block model)
Head: Metal
Approx. 370 g (Connector model)
Approx. 410 g (Terminal block model)
D4SL-N / D4SL-NSK10-LK@
12
Connection
Internal Circuit Diagram
Without indicator With indicator
Note: The numbers in boxes are the terminal numbers given on the Switch.
Circuit Connection Example
Direct opening contacts used as safety-circuit input are indicated with the mark.
Do not switch circuits for three or more standard loads at the same time.
Doing so may adversely affect insulation performance.
DC solenoids have polarity. (E1: Positive, E2: Negative)
Confirm terminal polarity before wiring.
If a lock is required for safety, design the system so that the closing of the NC contacts on both the door open/closed detection switch and the
lock monitor switch is detected.
Connection Example for D4SL-N@AF@-@
Contacts 12 and 41 are internally connected.
Connection Example for D4SL-N@EF@-D@
Contacts 12 and 41 are internally connected.
Connection Example for D4SL-N@SF@-@
There is no internal connection, so connect contacts 22 and 42 or 21
and 42 externally.
Connection Example for D4SL-N@NF@-D@
Contacts 12 and 41 and contacts 22 and 51 are internally connected.
D
D24VDC
E1 (+)
E2 ()
Z
D
Control
circuit
9
10
D
D24VDC
R
LED
E1 (+)
E2 ()
ZDControl
circuit
9
10
E1
(+)
E2
()
To control circuit
11
33
Lock monitor
switch
9
10
41
63
42
64
1
2
3
4
5
67
8
12
34 To control circuit
To safety circuit
(Not use)(Not use)
Door open/
closed detection
switch
E1
(+)
E2
()
To safety circuit
To control circuit
11
21
33
Lock monitor
switch
9
10
LED
41
63
42
22
64
1
2
3
4
5
67
8
12
34 To control circuit
To safety circuit
Door open/
closed detection
switch
E1
(+)
E2
()
To control circuit
21
41
33
Lock monitor
switch
9
10
63
42
22
64
1
2
3
4
5
67
834 To control circuit
To safety circuit
To safety circuit
Shortcircuit
Door open/
closed detection
switch
E1
(+)
E2
()
To safety circuit
To control circuit
11
21
33
Lock monitor
switch
9
10
LED
41
51
63
42
52
64
1
2
3
4
5
67
8
12
22
34 To control circuit
To safety circuit
Door open/
closed detection
switch
D4SL-N / D4SL-NSK10-LK@
13
Contact Form
Indicates conditions where the Key is inserted and the lock is applied.
Model
Contact
(door open/
closed detection
and lock monitor)
Contact Form
Operating pattern Remarks
Lock
monitor
Door open/
closed
detection
D4SL-N@A@@-@1NC/1NO+
1NC/1NO
Only NC contact 11-12 has a
certified direct opening
mechanism.
The terminals 42-11, 34-33, and
64-63 can be used as unlike
poles.
D4SL-N@B@@-@1NC/1NO+2NC
Only NC contact 11-12 has a
certified direct opening
mechanism.
The terminals 42-11, 34-33, and
62-61 can be used as unlike
poles.
D4SL-N@C@@-@2NC+1NC/1NO
Only NC contact 11-12 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-11, 32-31, and
64-63 can be used as unlike
poles.
D4SL-N@D@@-@2NC+2NC
Only NC contact 11-12 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-11, 32-31, and
62-61 can be used as unlike
poles.
D4SL-N@S@@-@1NC/1NO+
1NC/1NO
Only NC contact 21-22 has a
certified direct opening
mechanism.
The terminals 42-41, 22-21, 34-
33, and 64-63 can be used as
unlike poles.
D4SL-N@T@@-@1NC/1NO+2NC
Only NC contact 21-22 has a
certified direct opening
mechanism.
The terminals 42-41, 22-21, 34-
33, and 62-61 can be used as
unlike poles.
D4SL-N@U@@-@2NC+1NC/1NO
Only NC contact 21-22 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-41, 22-21, 32-
31, and 64-63 can be used as
unlike poles.
D4SL-N@V@@-@2NC+2NC
Only NC contact 21-22 and 31-
32 has a certified direct opening
mechanism.
The terminals 42-41, 22-21, 32-
31, and 62-61 can be used as
unlike poles.
42
64 63
41 12
Door open/closed
detection
Lock monitor
11
34 33
2
8
1
5
7 6
On
Stroke
42-11
34-33
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41 12 11
34 33
Door open/closed
detection
Lock monitor
2
8
1
5
7 6
On
Stroke
42-11
34-33
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
64 63
41 12 11
32 31
Door open/closed
detection
Lock monitor
2
8
1
5
7 6
On
Stroke
42-11
32-31
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41 12 11
3132
Door open/closed
detection
Lock monitor
2
8
1
5
7 6
On
Stroke
42-11
32-31
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
64 63
41
34 33
2122
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7 6
On
Stroke
42-41
22-21
34-33
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41
34 33
2122
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7 6
On
Stroke
42-41
22-21
34-33
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
64 63
41
32 31
2122
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7 6
On
Stroke
42-41
22-21
32-31
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41
32 31
2122
Door open/closed
detection
Lock monitor
2
8
3
4
1
5
7 6
On
Stroke
42-41
22-21
32-31
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
D4SL-N / D4SL-NSK10-LK@
14
Model
Contact
(door open/
closed detection
and lock monitor)
Contact Form
Operating pattern Remarks
Lock
monitor
Door open/
closed
detection
D4SL-N@E@@-@2NC/1NO+
1NC/1NO
Only NC contact 11-12 and 21-
22 has a certified direct opening
mechanism.
The terminals 42-11, 22-21, 34-
33, and 64-63 can be used as
unlike poles.
D4SL-N@F@@-@2NC/1NO+2NC
Only NC contact 11-12 and 21-
22 has a certified direct opening
mechanism.
The terminals 42-11, 22-21, 34-
33, and 62-61 can be used as
unlike poles.
D4SL-N@G@@-@3NC+1NC/1NO
Only NC contact 11-12 ,21-22
and 31-32 has a certified direct
opening mechanism.
The terminals 42-11, 22-21, 32-
31, and 64-63 can be used as
unlike poles.
D4SL-N@H@@-@3NC+2NC
Only NC contact 11-12 ,21-22
and 31-32 has a certified direct
opening mechanism.
The terminals 42-11, 22-21, 32-
31, and 62-61 can be used as
unlike poles.
D4SL-N@N@@-@2NC/1NO+
2NC/1NO
Only NC contact 11-12 and 21-
22 has a certified direct opening
mechanism.
The terminals 42-11, 52-21, 34-
33, and 64-63 can be used as
unlike poles.
D4SL-N@P@@-@2NC/1NO+3NC
Only NC contact 11-12 and 21-
22 has a certified direct opening
mechanism.
The terminals 42-11, 52-21, 34-
33, and 62-61 can be used as
unlike poles.
D4SL-N@Q@@-@3NC+2NC/1NO
Only NC contact 11-12 ,21-22
and 31-32 has a certified direct
opening mechanism.
The terminals 42-11, 52-21, 32-
31, and 64-63 can be used as
unlike poles.
D4SL-N@R@@-@3NC+3NC
Only NC contact 11-12 ,21-22
and 31-32 has a certified direct
opening mechanism.
The terminals 42-11, 52-21, 32-
31, and 62-61 can be used as
unlike poles.
42
64 63
41 12 11
34 33
2122
Door open/closed
detection
Lock monitor
2
8
3
1
4
5
7 6
On
Stroke
42-11
22-21
34-33
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41 12 11
34 33
2122
Door open/closed
detection
Lock monitor
2
8
3
1
4
5
7 6
On
Stroke
42-11
22-21
34-33
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
64 63
41 12 11
32 31
2122
Door open/closed
detection
Lock monitor
2
8
3
1
4
5
7 6
On
Stroke
42-11
22-21
32-31
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
62 61
41 12 11
2122
3132
Door open/closed
detection
Lock monitor
2
8
3
1
4
5
7 6
On
Stroke
42-11
32-31
22-21
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
52 51
64 63
41 12
Door open/closed
detection
Lock monitor
11
34 33
2122
2
8
43
1
5
7 6
On
Stroke
42-11
52-21
34-33
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
52 51
62 61
41 12 11
34 33
2122
Door open/closed
detection
Lock monitor
2
8
43
1
5
7 6
On
Stroke
42-11
52-21
34-33
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
52 51
64 63
41 12 11
32 31
2122
Door open/closed
detection
Lock monitor
2
8
43
1
5
7 6
On
Stroke
42-11
52-21
32-31
64-63
Operation Key Insertion
completion position Extraction
completion position
Lock position
42
52 51
62 61
41 12 11
2122
3132
Door open/closed
detection
Lock monitor
2
8
43
1
5
7 6
On
Stroke
42-11
52-21
32-31
62-61
Operation Key Insertion
completion position Extraction
completion position
Lock position
D4SL-N / D4SL-NSK10-LK@
15
Dimensions and Operating Characteristics (Unit:mm)
Switches
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
22
±0.2
4
(10.85
)(8)
(1)
26 dia.
A
Release key
4.5 dia. *
(depth: 1.6)
Front-side mounting
Two, 4.3 dia.
Mounting hole
LED indicators
22
±0.2
10
B
Label
4.5 dia. *
(depth: 1.6)
Side mounting
Three, 4.3 dia.
Mounting hole
29.2
29.2
Pre-travel distance
9
Head cap
Operation Key
One, Conduit
Conduit cap
Two, Cover mounting screw
26.3
(10.85)
B-B A-A
Release key
4.5 dia. *
(depth: 1.6)
LED indicators
26.3
4.5 dia. *
(depth: 1.6)
Spacers
41.7
±0.2
(62.75)
(73.5)
A
41.7
±0.2
(155)
41.7
±0.2
39
112.1
±0.8
(73.5)
31.5 42.9
(62.75)
B
39
38.7
±0.2
37
41.7
±0.2
38.5
D4SL-N@@@@-@N (Connector Type)
Model
Operating characteristics D4SL-N@@@@-@N
Key insertion force
Key extraction force
15 N max.
30 N max.
Pre-travel distance 15 mm max.
Movement before being locked 3 mm min.
* You can insert and secure a stud or
other projection in the 4.5-dia. hole to
make the installation even stronger.
For details, refer to “Switch and
Operation Key Mounting” on page 24.
Operation Key
B-B A-A
22
±0.2
4
(10.85
)
26 dia.
(1) (8)
4.5 dia. *
(depth: 1.6)
22
±0.2
10
29.2
29.2
Pre-travel distance
9
26.3
(10.85)
26.3
Release key
Spacers
Front-side mounting
Two, 4.3 dia.
Mounting hole
B
B
4.5 dia. *
(depth: 1.6)
LED indicators
4.5 dia. *
(depth: 1.6)
Release key
Side mounting
Three, 4.3 dia.
Mounting hole
4.5 dia. *
(depth: 1.6)
39
37
41.7
±0.2
38.5
38.7
±0.2
LED indicators
41.7
±0.2
Head cap
One, Conduit
Conduit cap
Two, Cover mounting screw
(179.9)
41.7
±0.2
A
A
137
±0.8
(73.5)
31.5 42.9
(62.75)
39
41.7
±0.2
(62.75)
(73.5)
D4SL-N@@@@-@ (Terminal Block Type)
Model
Operating characteristics D4SL-N@@@@-@
Key insertion force
Key extraction force
15 N max.
30 N max.
Pre-travel distance 15 mm max.
Movement before being locked 3 mm min.
* You can insert and secure a stud or
other projection in the 4.5-dia. hole to
make the installation even stronger.
For details, refer to “Switch and
Operation Key Mounting” on page 24.
D4SL-N / D4SL-NSK10-LK@
16
Operation key
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
22.7
2
21.5
7
74.3 Four, R2.15
35 15
2928
D4SL-NK1
22.7
2
19.5
13
Four, R2.15
7
74.3
35 15
29
D4SL-NK1S
22.7
Two, 9 dia.Two, 4.3 dia.
Mounting rubber 2
21.5
35 20
(5.2)
12
2928
D4SL-NK1G
22.7
2
15.6
Four, R2.15
35
7
7
14.5
4.3
8
15
29
D4SL-NK2
22.7
17.2
35
2
14.5
8
Two, 9 dia.
Two, 4.3 dia.
Mounting rubber
20
12
29
D4SL-NK2G
29
22.7 30
15
4.5 dia.
8 dia.
9 dia. 40
Angle adjustment bolt
56
20°
17.7
4
D4SL-NK3
15°
4
22.7
21.4 29
18° 18
4.5
15
17
22.5
24.4
41
6.5 (7)
41
5530 43 8
43
Angle adjustment bolt
Mounting Holes
(Enlargement)
D4SL-NK5
D4SL-N / D4SL-NSK10-LK@
17
Connector Cables
Slide Key
D4SL-NSK10-LK
8 dia.
Connector
Cable
AWG22, 10 conductors
*
* All 10 lead wires laid bare.
(Cross section of conductor: 0.3mm2 /Insulator diameter: 1.45mm)
Connector pin No.
10
9
8
7
6
5
4
3
2
1
(30) L ±40 (150)
(5)
D4SL-CN@
Model L size
D4SL-CN1 1 m
D4SL-CN3 3 m
D4SL-CN5 5 m
D4SL-CN10 10 m
Connector No. Lead wire color Connector No. Lead wire color
1 Black 6 Green/White
2 Black/White 7 Yellow
3Red 8Yellow/White
4 Red/White 9 Brown
5 Green 10 Brown/White
SLIDE
LOCK
SLIDE
FREE
SLIDE
LOCK
SLIDE
FREE
40×40
107
(147)
50 (64)
17
11.5
17
11.5
Four, M6
mounting holes
D4SL-NK1S
Operation Key
Guard Lock Safety-door Switch
D4SL-N
Three, M4
Two, M6
mounting holes
(32.5)
38.7
(35)
(26.8)
(35)
(20)
(56.5)
(76.2)
(330)
(314)
12.5
10
(112)
(232.2) (81.8)
(30.2)
(90.4)
(19.5)
(71.8)
19.1
8
Slide base
Shot bolt
Lockout key
Open door Close door
Guide
Switch base
A
A
B
B
12.5
22
20
11.6
4
4
Cross-sectional view B-B
Cross-sectional view A-A
(Between Slide Key)
15
+10
5
D4SL-N / D4SL-NSK10-LK@
18
D4SL-NSK10-LKH
Operation key Mounting
SLIDE
LOCK
SLIDE
FREE
SLIDE
LOCK
SLIDE
FREE
Slide base
D4SL-NK1S