Seal Leak Detector
Model 460-15-100-SLD
The PumpSaver® 460-15-100-SLD is a seal leak detector to
sense seal failures on submersible pumps. As water leaks
into the motor, the resistance measured by the probe de-
creases. When the resistance drops below the sensitivity
control level, the unit will trip and the relay contacts will
change state.
orders@symcom.com / customerservice@symcom.com
(605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685
2.350
Specications
orders@symcom.com / customerservice@symcom.com
(605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685
How to order:
Part Number: 460-15-100-SLD
Functional Specications:
Sensitivity: 4.7-100kΩ
Input Characteristics:
Supply Voltage:
Frequency:
110/120VAC nominal
50/60Hz
Output Characteristics
Output Contact Rating-DPST: 360VA@240VAC Pilot Duty
8A@240VAC General Purpose
General Characteristics:
Operating Temperature:
Ambient Operating:
Ambient Storage:
Power Consumption:
Relative Humidity:
Terminals:
Wire Size
Torque
Standards Passed:
Electrostatic Discharge (ESD)
Radio Frequency Immunity (RFI)
Fast Transients
Surge:
IEC
ANSI/IEEE
Hi-Potential Test
Class of Protection:
Safety Marks:
UL
Dimensions
Weight
Mounting Methods:
-20º to 70ºC (-4º to 158º F)
-40º to 80ºC (-40º to 176º F)
2 Watts (max.)
10-95%, non-condensing per IEC 68-2-3
12-20AWG
6 in.-lbs.
IEC 100-4-2, Level 3, 6kV contact, 8kV air
159 MHz, 10V/m
IEC 1000-4-4, Level 3, 3.5kV input power and controls
IEC 1000-4-5, Level 3, 4kV line-to-line; Level 4, 4kV
line-to-ground
C62.41 Surge and Ring Wave Compliance to a level of
6kV line-to-line
Meets UL508 (2 x rated V + 1000 V for 1 minute)
IP20, NEMA 1 (nger safe)
UL508
3.5” L x 2.084” W x 2.35” H
1 lb. (max.)
35 mm DIN rail or Surface Mount (#6 or #8 screws)