774
The retainer provides added protection
against non-insertion or disconnection.
Features––––––––––––––––––––––––
• Inner-housing lock
This inner-housing lock secures the plug to the receptacle and
prevents accidental disconnection. The lock is protected and
is not affected by external forces that might result from the
routing of wires.
• Secondary retainers
The secondary retainers enhance safety in case of partial
insertion or accidental release of the contact. Even if a contact
is inserted incompletely, the retainer guides the contact to the
proper position and securely locks it in place.
• Housing lance
The resilient plastic housing lances secure the contacts in
the housings. Since the lances are part of the housings rather
than on the contacts, they are not affected by handling, and
allow the contacts to be lightly inserted without undue force.
This establishes a feeling of uniform insertion and a noticeable
change in that feeling when insertion is completed.
• Mountable on a variety of panels
Due to our unique panel installation locking mechanisms, the
housing can be easily installed on panels of various thickness
without using tools.
• Contacts smoothly insert into the housings
without colliding with internal obstacles
Housings have pin insertion guides that provide smooth and
easy insertion without contact deflection or collision against
internal housing walls.
Specifications –––––––––––––––––––
• Current rating: 3A AC, DC max.
• Voltage rating: 250V AC, DC max.
• Temperature range: -25˚C to +85˚C
(including temperature rise in applying
electrical current)
• Contact resistance: Initial value/10m Ωmax.
After environmental testing/20m Ωmax.
• Insulation resistance: 500M Ωmin.
• Withstanding voltage: 1,500V AC/minute
• Applicable wire: AWG #28 to #20
0.08 to 0.50mm2
• Applicable panel thickness: 0.5 to 1.8mm(.020" to .071")
* Contact JST if Lead-Free product is required.
* Refer to "General Instruction and Notice when using
Terminals and Connectors" at the end of this catalog.
* Contact JST for details.
Standards–––––––––––––––––––––––
0Recognized E60389
1Certified LR20812