SIMATIC NET
PG/PC - PROFIBUS
CP 5613 A2/CP 5614 A2
Operating Instructions
08/2016
C79000
-G8976-C301-02
Preface
1
Description of the device
2
Software installation
3
Hardware installation
4
Configuration
5
Technical specifications
6
Certification
A
Siemens AG
Division Process Industries and Drive
s
Postfach 48 48
90026 NÜRNBERG
GERMANY
Document order number: C79000-G8976-C301
09/2016 Subject to change
Copyright © Siemens AG 2016.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified
for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 3
Table of contents
1 Preface ................................................................................................................................................... 5
2 Description of the device ......................................................................................................................... 9
2.1 CP 5613 A2 product characteristics ......................................................................................... 9
2.2 CP 5614 A2 product characteristics ....................................................................................... 11
2.3 PROFIBUS interface ............................................................................................................... 12
2.4 Meaning of the LED display .................................................................................................... 13
3 Software installation .............................................................................................................................. 15
3.1 Installing the "SIMATIC NET PC Software" ............................................................................ 15
3.2 Uninstalling the "SIMATIC NET PC Software"........................................................................ 16
4 Hardware installation ............................................................................................................................. 17
4.1 Safety notices ......................................................................................................................... 17
4.2 Installing hardware .................................................................................................................. 18
4.2.1 Automatic adaptation of the bus clock speed ......................................................................... 18
4.2.2 Installing hardware PCI ........................................................................................................... 18
4.3 Hardware compatibility............................................................................................................ 19
4.3.1 Compatibility with other CPs ................................................................................................... 19
4.3.2 Replacement ........................................................................................................................... 19
5 Configuration ........................................................................................................................................ 21
6 Technical specifications ........................................................................................................................ 23
A Certification ........................................................................................................................................... 27
Table of contents
CP 5613 A2/CP 5614 A2
4 Operating Instructions, 08/2016, C79000-G8976-C301-02
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 5
Preface
1
What the consignment contains
The following components are supplied with the CP 5613 A2/CP 5614 A2:
Communications processor CP 5613 A2/CP 5614 A2
SIMATIC NET CD
Certificate of license
Please check that the consignment you have received is complete. If the consignment is
incomplete, contact your supplier or your local Siemens office.
Validity of this documentation
These operating instructions are valid for the following products:
CP 5613 A2
Article number: 6GK1 561-3AA01
CP 5614 A2
Article number: 6GK1 561-4AA01
Content of this documentation
These operating instructions contain information about the installation and configuration of
the CP 5613 A2 and CP 5614 A2 communications processors.
Updated operating instructions on the Internet
You will find the current version of these operating instructions on the Product Support pages
under the following entry ID: 62612014
(https://support.industry.siemens.com/cs/ww/en/view/62612014)
Further documentation
The documents listed below contain more detailed information on commissioning and using
the communications processor. You will find this documentation on the Product Support
pages on the Internet under the following entry link:
Support (https://support.industry.siemens.com/cs/ww/en/ps)
Preface
CP 5613 A2/CP 5614 A2
6 Operating Instructions, 08/2016, C79000-G8976-C301-02
Enter the entry ID shown below of the relevant manual as the search item.
Configuration manual Commissioning PC Stations
This provides you with detailed information on commissioning and configuring SIMATIC
NET PC communications modules.
Entry ID:
109488960 (https://support.industry.siemens.com/cs/ww/en/view/109488960)
System manual SIMATIC NET Industrial Communication with PG/PC
Volume 1Basics
Entry ID:
77376110 (https://support.industry.siemens.com/cs/ww/en/view/77376110)
Volume 2Interfaces
Entry ID:
77378184 (https://support.industry.siemens.com/cs/ww/en/view/77378184)
The system manuals introduce the topic of industrial communication and explain the
communications protocols used. There is also a description of the OPC interface as
user programming interface.
Installation manual "SIMATIC NET PC Software"
This document contains detailed information on installing the "SIMATIC NET
PC Software".
Entry ID:
77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602)
System manual PROFIBUS Network Manual
In this document you will find detailed information about setting up a PROFIBUS network.
Entry ID:
35222591 (https://support.industry.siemens.com/cs/ww/en/view/35222591)
SIMATIC NET documentation
You will find the entire SIMATIC NET documentation on the pages of Product Support:
15247 (https://support.industry.siemens.com/cs/ww/en/ps/15247)
Go to the required product group and make the following settings:
Entry list Entry type "Manuals / Operating Instructions"
Trademarks
The following and possibly other names not identified by the registered trademark sign ® are
registered trademarks of Siemens AG:
SIMATIC NET, HARDNET, SOFTNET, CP 1612, CP 1613, CP 5612, CP 5613, CP 5614,
CP 5622
Preface
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 7
Industry Online Support
In addition to the product documentation, the comprehensive online information platform of
Siemens Industry Online Support at the following Internet address:
(http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang=
en)
Apart from news, there you will also find:
Project information: Manuals, FAQs, downloads, application examples etc.
Contacts, Technical Forum
The option submitting a support query:
(https://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid
=38718979&caller=view)
Our service offer:
Right across our products and systems, we provide numerous services that support you
in every phase of the life of your machine or system - from planning and implementation
to commissioning, through to maintenance and modernization.
You will find contact data on the Internet at the following address:
(http://www.automation.siemens.com/partner/guiwelcome.asp?lang=en)
SITRAIN - Training for Industry
The training offer includes more than 300 courses on basic topics, extended knowledge and
special knowledge as well as advanced training for individual sectors - available at more
than 130 locations. Courses can also be organized individually and held locally at your
location.
You will find detailed information on the training curriculum and how to contact our customer
consultants at the following Internet address:
(www.siemens.com/sitrain)
SIMATIC NET glossary
Explanations of many of the specialist terms used in this documentation can be found in the
SIMATIC NET glossary.
You will find the SIMATIC NET glossary on the Internet at the following address:
50305045 (https://support.industry.siemens.com/cs/ww/en/view/50305045)
Preface
CP 5613 A2/CP 5614 A2
8 Operating Instructions, 08/2016, C79000-G8976-C301-02
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 9
Description of the device
2
2.1
CP 5613 A2 product characteristics
CP 5613 A2 characteristics
The CP 5613 A2 is a communications processor for connecting PCs to PROFIBUS. The
essential characteristics are as follows:
The CP 5613 A2 is equipped with a PROFIBUS interface allowing up to 12 Mbps. It is
intended for operation in PGs and PCs with a PCI bus interface according to the PCI
standard V2.2.
With the CP 5613 A2, up to 32 devices (PC, PG, SIMATIC S7 or ET 200) can be linked to
form a network segment. By linking several segments with repeaters, a maximum of 124
nodes can be connected.
Optimized for fast DP master operation (DP Base) with up to 124 DP slaves with full data
consistency
As an alternative, can also be used as a DP slave
Relieves the PC due to event mechanisms (automatic detection of data changes)
Fast logic support regardless of the user program (automatic linking of input and output
data can be set by the user program).
Plug and play support during installation of the hardware
Support of all data transmission speeds from 9.6 kbps to 12 Mbps
Floating RS-485 connector
Support of PCI 3.3 V/5 V, 33 MHz/66 MHz, 32 bit/64 bit and PCI-X 66 MHz, 32 bit/64 bit
Description of the device
2.1 CP 5613 A2 product characteristics
CP 5613 A2/CP 5614 A2
10 Operating Instructions, 08/2016, C79000-G8976-C301-02
CP 5613 A2 appearance
The following figure shows the CP 5613 A2 communications processor:
A
Yellow and green status LED
B
PROFIBUS interface 1 (master or slave)
Description of the device
2.2 CP 5614 A2 product characteristics
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 11
2.2
CP 5614 A2 product characteristics
CP 5614 A2 characteristics
The CP 5614 A2 is a communications processor for connecting PCs to PROFIBUS. It has
the same characteristics as the CP 5613 A2, as well as:
Second RS-485 connector for additional connection of the CP as a DP slave to a second
DP network.
Program-controlled transfer of data between master and slave module to allow for setting
up of hierarchical PROFIBUS networks.
DP master and DP slave can be operated at the same time.
CP 5614 A2 appearance
The following figure shows the CP 5614 A2 communications processor:
A
Yellow and green status LED
B
PROFIBUS interface 1 (master)
C
PROFIBUS interface 2 (slave)
Description of the device
2.3 PROFIBUS interface
CP 5613 A2/CP 5614 A2
12 Operating Instructions, 08/2016, C79000-G8976-C301-02
2.3
PROFIBUS interface
PROFIBUS network
The physical link between the PROFIBUS interface and the PROFIBUS network is via a
floating RS-485 interface that is part of the module. Depending on the network configuration,
data rates of 9.6 Kbps up to a maximum of 12 Mbps are possible in the PROFIBUS network.
Note
You will find information about the structure of a PROFIBUS network in the system manual
"PROFIBUS Network Manual". The document is part of the Manual Collection. You will also
find this on the Product Support pages under the following ent
ry ID:
35222591 (
https://support.industry.siemens.com/cs/ww/en/view/35222591)
PIN assignment
The D-sub female connector has the following pin assignment:
PIN
Short name
Meaning
Input/output
1
NC
Socket pin 1 is not connected.
-
2 NC (M24) Socket pin 2 is not connected. With other MPI/DP components,
the return line of the floating 24 V power supply may be via this
pin.
-
3
LTG_B
Signal line B of the PROFIBUS connector.
Input/output
4 RTSAS RTSAS, input signal for direct MPI link. The control signal is "1"
active when the automation system connected over a special
MPI cable is sending.
Input
5 M5EXT M5EXT return line (GND) of the 5 V power supply. The current
load of an external consumer connected between P5EXT and
M5EXT must not exceed a maximum of 90 mA.
Output
6 P5EXT P5EXT supply (+5 V) of the 5 V power supply. The current load
of an external consumer connected between P5EXT and
M5EXT must not exceed a maximum of 90 mA (short-circuit
proof).
Output
7 NC (P24V) Socket pin 7 is not connected. With other MPI/DP components,
the P24V supply of the floating 24 V power supply may be via
this pin.
-
8
LTG_A
Signal line A of the PROFIBUS connector.
Input/output
Description of the device
2.4 Meaning of the LED display
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 13
PIN
Short name
Meaning
Input/output
9 RTS RTS output signal of the CP module. The control signal is "1"
active when the device (PG or PC) is sending.
Output
Shield The shield is connected to components of the connector hous-
ing.
2.4
Meaning of the LED display
LED display
The meaning of the LED display is as follows:
Green and yellow LED
Function
Lit green DP master
Shows the token rotation (in other words, normal operation)
Green off DP master
Incorrect bus parameters, defective bus or CP not in opera-
tion
Green flashes at one second intervals DP master
Bad database
Green and yellow flashing alternately Module is being addressed by diagnostics tool to check
installation
Yellow lit DP slave
Shows polling by the higher-level DP master
(in other
words normal operaton)
Yellow off DP slave
Connector is not addressed
Green flashing fast
Module not started (normal status following reset)
Green and yellow flashing synchronized
Exception status (error in firmware)
Description of the device
2.4 Meaning of the LED display
CP 5613 A2/CP 5614 A2
14 Operating Instructions, 08/2016, C79000-G8976-C301-02
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 15
Software installation
3
3.1
Installing the "SIMATIC NET PC Software"
"SIMATIC NET PC Software"
The "SIMATIC NET PC software" is one of several software packages with which you can
operate the communications processor in your PG/PC.
To configure the communications processor, you require additional configuration software.
You will find information on the configuration software in the section "Configuration
(Page 21)".
Condition
The plug and play function is activated in the BIOS of your PG/PC.
Prior to hardware installation
Install the software as described in the installation manual "SIMATIC NET PC Software".
You will find this installation manual on the Product Support pages under the following entry
ID:
77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602)
You should also note the current information on the "SIMATIC NET PC software" on the
Product Support pages:
Support (https://support.industry.siemens.com/cs/ww/en/ps/15362/pm)
After the hardware installation
After installing the communications processor, your PG/PC automatically searches for a
suitable driver.
1. Follow the instructions of the Hardware Wizard of Windows.
2. Do not activate the search for drivers on the Internet.
Software installation
3.2 Uninstalling the "SIMATIC NET PC Software"
CP 5613 A2/CP 5614 A2
16 Operating Instructions, 08/2016, C79000-G8976-C301-02
3.2
Uninstalling the "SIMATIC NET PC Software"
Condition
The "SIMATIC NET PC Software" is installed on the PG/PC.
Procedure
Note
The recommended procedure removes the entire "SIMATIC NET PC Software" on the
PG/PC, not only the driver for the communications processor.
Uninstall the entire software package as described and recommended in the installation
manual "SIMATIC NET PC Software".
You will find the installation manual on the "SIMATIC NET PC Software" DVD or on the
Product Support pages under the following entry ID:
77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602)
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 17
Hardware installation
4
4.1
Safety notices
WARNING
Electric shock possible - work only when the power supply is off
Opening the PG/PC and plugging or pulling the communications processor is permitted
only when the power is off.
Turn off your PG/PC and pull the power cable connector before you start the hardware
installation.
NOTICE
Note the EC directives
Components can be damaged or destroyed by electrostatic discharge. When installing,
keep to the rules for electrostatically sensitive devices (ESD).
Pick up components and modules only by their edges. Do not touch the pins or
conductors.
Before opening the PG/PC, make sure that you discharge any electrostatic charge from
your body. You can do this by touching metal parts on the back panel of the PG/PC
pulling the power plug.
Make sure that you also discharge any electrostatic charge from tools you intend to use
for the work on the PG/PC.
Do not operate the PG/PC with the housing open.
NOTICE
Firm mounting
The communications processor must sit firmly and uniformly in the slot. Check that the
module sits firmly in the slot as described in the manual accompanying your PG/PC.
Note
Oblique installation position is permitted
Some PG/PC designs require oblique installation of the communications processor. This is
permitted.
Hardware installation
4.2 Installing hardware
CP 5613 A2/CP 5614 A2
18 Operating Instructions, 08/2016, C79000-G8976-C301-02
4.2
Installing hardware
Permitted number of communications processors in the PG/PC
The driver software supports a maximum of 4 communications processor per PG/PC.
4.2.1
Automatic adaptation of the bus clock speed
Automatic adaptation of the bus clock speed
The communications processor is designed for a bus clock speed of 66 MHz. If the
communications processor is inserted in a PCI slot with a higher bus clock speed, the bus
clock speed is adapted to the highest possible bus rate of the communications processor.
Examples:
The PCI slot is automatically reduced to a bus clock speed of 66 MHz.
The bus clock speed of the communications processor is automatically reduced to
33 MHz if a communications processor with a 33 MHz bus clock speed is connected.
4.2.2
Installing hardware PCI
Procedure
Note
First install the software
First install the software before you insert the communications processor in the slot.
Activated plug and play function
The plug and play function must be activated in the BIOS of your PG/PC.
Follow the steps outlined below when inserting the communications processor:
1. Turn off your PG/PC and pull the power cable connector.
2. Open the PC housing as described in the manual accompanying your PG/PC.
3. Remove the cover of a free PCI slot.
4. Remove the communications processor from its packaging.
5. Insert the communications processor in the PCI slot and secure it.
Make sure that the communications processor is correctly inserted and secured.
6. Close the PC housing as described in the manual accompanying your PG/PC.
Hardware installation
4.3 Hardware compatibility
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 19
7. Insert the power plug into the socket again and turn your PG/PC on.
The plug and play function of Windows automatically searches for a driver.
8. Follow the instructions of the Hardware Wizard of Windows.
Do not
activate the search for drivers on the Internet.
4.3
Hardware compatibility
4.3.1
Compatibility with other CPs
Compatibility with other communications processors
The communications processors CP 5613 A2 and CP 5614 A2 can replace the following
communications processors:
CP 5613
CP 5614
4.3.2
Replacement
Note
If the previous CP has been removed from the PG/PC, no configuration changes need to be
made
You can adopt the configuration of the previous CP. To do this, you simply need to reload
the configuration.
Note the following:
When loading the previous configuration, the previous CP has priority
over the new CP. As long as the previous CP is connected, its configuration cannot be
adopted by the new CP. You should therefore remove the previous CP from your PC/PG.
Procedure for replacement
When replacing a module, follow the steps described in the section "Hardware installation
(Page 17)".
Hardware installation
4.3 Hardware compatibility
CP 5613 A2/CP 5614 A2
20 Operating Instructions, 08/2016, C79000-G8976-C301-02
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 21
Configuration
5
Configuring
To be able to configure the communications processor, the following engineering or
configuration tools are available:
STEP 7 V5.5
STEP 7 Professional (TIA Portal)
Communication Settings (COML S7)
The steps involved are described in the "Commissioning PC Stations" manual or in the
relevant online helps.
NOTICE
No downloading of a CP 5613 A2 slave configuration to a CP 5614 A2
A DP slave configuration for a CP 5613 A2 must not be downloaded to a CP 5614 A2
because the DP slave will not work with this configuration.
Configuration
CP 5613 A2/CP 5614 A2
22 Operating Instructions, 08/2016, C79000-G8976-C301-02
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 23
Technical specifications
6
Technical specifications for CP 5613 A2/CP 5614 A2
Construction
Values
Module format
PC card, short PCI format
Dimensions (H x W x D) in mm
107 x 18 x 168
Weight CP 5613 A2: 105 g
CP 5614 A2: 120 g
Bus interface
PCI V2.2, plug and play
Voltage
Operating voltage
Safety extra low voltage (SELV) to EN 60950
Rated voltage (limit values)
5 VDC (4.75 to 5.25 V)
Current consumption
Current consumption from PCI slot CP 5613 A2: typical: 0.8 A
CP 5614 A2: typical: 0.9 A
Interfaces
Connection to PG/PC
PCI/PCI-X slot , 3.3 V/5 V, 32 bit, 33/66 MHz bus clock
Connector to PROFIBUS 9-pin D-sub female connector with screw locking mecha-
nism
The CP 5614 A2 has two interfaces. If both interfaces of the
CP 5614 A2 are used, straight bus connectors must be
used.
The following network components are recommended for
connection to PROFIBUS:
RS-485 bus connector,
article number 6GK1500-0EA01
12M bus terminal,
article number 6GK1500-0AA10
Type of transmission
RS-485 floating within the SELV limits
Technical specifications
CP 5613 A2/CP 5614 A2
24 Operating Instructions, 08/2016, C79000-G8976-C301-02
Interfaces
Mode of the PROFIBUS interface Floating (interface signals),
non-floating (cable shield)
PROFIBUS controller used CP 5613 A2 / CP 5614 A2
Master: ASPC2R ST E2a
CP 5614 A2
Slave: DPC31
Data transfer
Transmission speed
9.6 kbps ... 12 Mbps
Electromagnetic compatibility (EMC)
Emission Class B to EN 55022
FCC class B
Noise immunity on signal lines +/- 2 kV
to EN 61000-4-5, surge
Immunity to discharges of static electricity +/- 6 kV, contact discharge to
IEC 61000-4-2
Immunity to RF interference 10 V/m at
80 MHz to 2 GHz to EN 61000-4-3
10 V/m 50 % ON period at 900 MHz and 1.89 GHz
to EN 61000-4-3
10 V/m with 80 % amplitude modulation
with 1 kHz,
9 kHz - 80 MHz to EN 61000-4-6
Climatic Conditions
Temperature Tested to:
DIN EN 60068-2-1,
DIN EN 60068-2-2,
DIN EN 60068-2-14
Operation
Temperature change maximum 10 K/h
Transportation/storage temperature -40 to +70
Temperature change maximum 20 K/h
Relative humidity tested to DIN IEC 60068-2-78
in operation
85% at 30 (no condensation)
tested to DIN IEC 60068-2-30
storage/transportation:
5 % at 25 - 55 °C (no condensation)
Technical specifications
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 25
Mechanical environmental conditions
Vibration during operation tested to DIN EN 60068-2-6
during operation
10 to 58 Hz, amplitude 0.0375 mm;
58 to 500 Hz, acceleration 4.9 m/s²
3 axes
Shock during operation Tested to DIN EN 60068-2-27
during operation
half sine: 50 m/s² (5 g), 30 ms
3 axes
Technical specifications
CP 5613 A2/CP 5614 A2
26 Operating Instructions, 08/2016, C79000-G8976-C301-02
CP 5613 A2/CP 5614 A2
Operating Instructions, 08/2016, C79000-G8976-C301-02 27
Certification
A
Note
The specified approvals apply only when the corresponding mark is printed on the
communications processor.
Electromagnetic compatibility - EMC directive
The communications processor meets the requirements of the EC Directive:2004/108/EEC
(EMC directive).
The communications processor is designed for use in the following areas:
Area of application
Requirements
Emission
Immunity
Residential areas, business and commercial opera-
tions, and small businesses
EN 61000-6-3 EN 61000-6-1
Industrial environment
EN 61000-6-4
EN 61000-6-2
Declaration of conformity
You will find the declaration of conformity for this communications processor on the Product
Support pages under the following entry ID:
58826997 (https://support.industry.siemens.com/cs/ww/en/view/58826997)
C-TICK approval
The communications processor meets the requirements of the Australian AS/NZS 3548
standard according to EN 61000-6-3.
CSA approval
The communications processor has an approval in accordance with the Canadian CAN/CSA
C22.2 No. 60950-1 standard.
ICES conformity
The communications processor meets the requirements of the Canadian standard ICES-003.
It is rated as a digital device of Class B ("Class B digital apparatus").
Certification
CP 5613 A2/CP 5614 A2
28 Operating Instructions, 08/2016, C79000-G8976-C301-02
FCC approval
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Siemens AG is not responsible for any radio television interference caused by unauthorized
modifications of this equipment or the substitution or attachment of connecting cables and
equipment other than those specified by Siemens AG. The correction of interference caused
by such unauthorized modification, substitution or attachment will be the responsibility of the
user. The use of shielded I/O cables is required when connecting this equipment to any and
all optional peripheral or host devices. Failure to do so may violate FCC and ICES rules.
UL approval
The communications processor has an approval in accordance with the US standard
UL 60950-1.
Marking for the customs union
EAC (Eurasian Conformity)
Customs union of Russia, Belarus and Kazakhstan
Declaration of the conformity according to the technical regulations of the customs union
(TR CU)