119 AHT-DIN
www.vishay.com Vishay BCcomponents
Revision: 09-Jan-17 1Document Number: 28335
For technical questions, contact: aluminumcaps1@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Aluminum Electrolytic Capacitors
Axial High Temperature, DIN-Based
Fig. 1
FEATURES
• Extra long useful life: up to 8000 h at 125 °C
• High stability, high reliability
• Extended temperature range: 125 °C (usable up
to 150 °C)
• High ripple current capability
• Taped versions up to case Ø 15 mm x 30 mm available for
automatic insertion
• Polarized aluminum electrolytic capacitors, non-solid
electrolyte
• Axial leads, cylindrical aluminum case, insulated with a
blue sleeve
• Mounting ring version not available in insulated form
• Charge and discharge proof
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
APPLICATIONS
• Military, industrial control, EDP and telecommunication
• Smoothing, filtering, buffering in SMPS; coupling,
decoupling
• For use where low mounting height is important; vibration
and shock resistant
MARKING
The capacitors are marked (where possible) with the
following information:
• Rated capacitance (in μF)
• Tolerance on rated capacitance, code letter in accordance
with IEC 60062 (T for -10 % to +50 %)
• Rated voltage (in V) at 125 °C and 85 °C
• Date code, in accordance with IEC 60062
• Code for factory of origin
• Name of manufacturer
• Negative terminal identification
• Series number (119)
QUICK REFERENCE DATA
DESCRIPTION VALUE
Nominal case sizes
(Ø D x L in mm)
6.5 x 18
to 10 x 25
10 x 30
to 21 x 38
Rated capacitance range, CR4.7 μF to 4700 μF
Tolerance on CR-10 % / +50 %
Rated voltage range, UR10 V to 100 V
Category temperature range -55 °C to +125 °C
Endurance test at 150 °C 500 h 500 h
Endurance test at 125 °C 2000 h 4000 h
Useful life at 125 °C 4000 h 8000 h
Useful life at 40 °C,
1.8 x IR applied 500 000 h 1 000 000 h
Shelf life at 0 V, 125 °C:
UR = 10 V to 63 V 500 h
UR = 100 V 100 h
Based on sectional
specification IEC 60384-4 / EN 130300
Climatic category IEC 60068 55 / 125 / 56
smaller
dimensions
smaller dimensions
higher ripple
119 AHT-DIN
125 °C
118 AHT
120 ATC
125 °C
SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES (Ø D x L in mm)
CR
(μF)
UR (V)
10 16 25 40 63 100
4.7 - - - - - 6.5 x 18
10 - - - - 6.5 x 18 -
22 - - 6.5 x 18 - 8 x 18 -
47 - 6.5 x 18 - 8 x 18 10 x 18 10 x 25
-----10 x 30
68 - - - - 10 x 30 12.5 x 30
100 6.5 x 18 8 x 18 10 x 18 10 x 25 10 x 30 15 x 30
150 - - - 12.5 x 30 15 x 30 15 x 30