TQM963001 BC14 / B25 BAW Duplexer Applications CDMA / LTE handsets Data card Mobile router Extension PCS Band Class 14 LTE Band 25 8 Pin 2.6 x 2.1 mm Package Product Features Functional Block Diagram Excellent triple beat performance: -88 dBc Highly selective BAW duplexer achieving low insertion loss over full bandwidth and operating conditions. Downlink isolation of 50 dB minimum & GPS rejection of >40 dB eliminating the need for a transmit filter Single-Ended (SE) 50 Ohm Downlink & Uplink Ports Performance -30 to +85 C RoHS compliant, Pb-free module package General Description Top View Pin Configuration The TQM963001 is a high-performance Bulk Acoustic Wave (BAW) duplexer designed to meet the strict CDMA requirements in the PCS extension band BC14 and provide excellent insertion loss, cross isolation and linearity for LTE B25. TQM963001 is specifically designed to meet the high performance expectations of insertion loss, isolation and triple beat for CDMA systems over the extended bandwidth of BC14 applications under all operating conditions. Exceptional downlink isolation and GPS rejection performance eliminates the need for an uplink SAW filter. Pin # Symbol 1 3 6 8 2, 4, 5, 7, Center Pad DL (Downlink) UL (Uplink) Ant (Antenna) GND (Optional) GND The TQM963001 uses common module packaging techniques to achieve the industry standard 2.6 x 2.1 x 0.9 mm footprint. This duplexer exhibits excellent power handling capabilities. Ordering Information Part No. Description TQM963001 TQM963001-PCB BC14 / B25 BAW Duplexer Evaluation Board Standard T/R size = 2500 pieces on a 7" reel. Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint - 1 of 9 - Disclaimer: Subject to change without notice www.triquint.com TQM963001 BC14 / B25 BAW Duplexer Absolute Maximum Ratings Recommended Operating Conditions Parameter Parameter Min Typ Max Units TCASE -30 Rating Storage Temperature RF Input Power CW, 5000 hours, 50 ,T = 25 C -40 to +85 C +29 dBm +85 C The duplexer will function over the recommended range without degradation in reliability or permanent change in performance. Operation of this device outside the parameter ranges given above may cause permanent damage. Electrical Specifications(1,2) Antenna-Uplink Test conditions unless otherwise noted: Temp. = -30 C to +85 C Parameter Conditions Insertion Loss 1850 - 1915 MHz (B25) 1850 - 1915 MHz (Antenna Port) 1850 - 1915 MHz (Uplink Port) 10 - 728 MHz 728 - 768 MHz 869 - 894 MHz 1565 - 1587 MHz (GPS) 1597 - 1606 MHz (Glonass) 1606 - 1680 MHz 1930 - 1995 MHz (B25 Downlink) 2110 - 2155 MHz (AWS Downlink 2400 - 2500 MHz (ISM) 3700 - 3830 MHz (2 f0) 5150 - 5350 MHz (WiFi) 5550 - 5745 MHz (3 f0) 7390 - 7670 MHz (4 f0) 1850 - 1915 MHz (B25) Return Loss Attenuation Amplitude Variation(4) Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint - 2 of 9 - Min Typ(3) Max Units 1.8 12 15 42 43 46 50 51 44 53 39 30 26 24 22 21 0.7 3.8 dB 9 11 30 30 35 40 42 30 40 34 26 20 15 15 10 dB dB 1.7 dB Disclaimer: Subject to change without notice www.triquint.com TQM963001 BC14 / B25 BAW Duplexer Electrical Specifications(1,2) Antenna-Downlink Test conditions unless otherwise noted: Temp. = -30 C to +85 C Parameter Conditions Insertion Loss 1930 - 1995 MHz (B25) 1930 - 1995 MHz (Antenna Port) 1930 - 1995 MHz (Downlink Port) 815 - 849 MHz (BC0 Uplink) 1850 - 1915 MHz (B25 Uplink) 2400 - 2484 MHz (ISM band) 2484 - 8000 MHz Return Loss Attenuation Amplitude Variation(4) Linearity (Triple Beat Test)(6) Min Typ(3) Max Units 5.1 dB 9 9 20 45 30 25 2.2 11 11 32 63 43 47 1.3 1.8 dBp-p -88(5) -79 dBc Min Typ(3) Max Units 51 47 40 53 49 20 62 54 56 64 59 1930 - 1995 MHz (B25) Ratio of CW jammer to triple beat product at downlink port. Temp=+25 C dB dB Electrical Specifications(1,2) Uplink-Downlink Isolation Test conditions unless otherwise noted: Temp. = -30 C to + 85 C Parameter Isolation Mid band Isolation(4) Frequency Band 1850 - 1915 MHz (B25) 1930 - 1995 MHz (B25) 1574 - 1577 MHz (GPS) 3700 - 3830 MHz (2 f0) 5540 - 5745 MHz (3 f0) 1915 - 1930 MHz, Temp=+25 C dB dB Notes: 1. All specifications are based on the TriQuint schematic for the main reference design. 2. In production, devices will be tested at room temperature to a guard-banded specification to ensure electrical compliance over temperature. 3. Typical values are averages over specified band, unless otherwise noted. 4. Integrated over any 1.25 MHz channel within band. 5. Worst case over specified frequencies. 6. Test conditions defined as follows: Uplink port: Two CW signals at fuplink and fuplink+1MHz and Pout=+21.5 dBm per tone measured at the DUT antenna port; Antenna port: CW jammer at fdownlink= fuplink+ 80 MHz and Pin=-30 dBm. Triple Beat Ratio is defined as the ratio of the CW jammer to the triple-beat product at the downlink port for fuplink =1851 MHz, 1882 MHz, and 1913 MHz. Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint - 3 of 9 - Disclaimer: Subject to change without notice www.triquint.com TQM963001 BC14 / B25 BAW Duplexer TQM963001-PCB Evaluation Board Notes: 1. 2. 3. 4. Notes: 1. Top, middle & bottom layers: 1 oz copper 2. Substrates: FR4 dielectric, .031" thick 3. Finish plating: Nickel: 3-8m thick, Gold: .03-.2m thick 4. Hole plating: Copper min .0008m thick Light grey indicates metalized area Dark grey indicates pad areas This footprint represents a recommendation only For solder pad recommendation see mechanical information UL In DL Out 2, 3, 5, 7 Center Pad Pin 8 can be connected to ground or left floating Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint - 4 of 9 - Disclaimer: Subject to change without notice www.triquint.com TQM963001 BC14 / B25 BAW Duplexer Downlink Performance Plots - TQM963001-PCB Temp=25C Downlink Antenna Narrowband Response Downlink Antenna Pass Band 0 0 -10 -1 |S21| (dB) |S21| (dB) -20 -30 -40 -2 -3 -50 -4 -60 -70 -5 1800 1850 1900 1950 2000 2050 2100 1920 1940 1960 Frequency (MHz) 1980 2000 2020 2000 2020 Frequency (MHz) Downlink Return Loss Downlink Antenna Wideband Response 0 0 -10 -5 |S11| (dB) |S21| (dB) -20 -30 -40 -10 -15 -50 -20 -60 -70 -25 5000 6000 7000 8000 Frequency (MHz) 1.0 2.0 - 5 of 9 - -1.0 6 Swp Min 1930MHz 10.0 3.0 4.0 5.0 2.0 1.0 4 - 0. -1.0 .0 -2 . -0 .0 -2 -3 .0 -0.8 0.8 -0.2 - 4. 0 -5.0 - 0. 6 10.0 0.6 0 10.0 3.0 4.0 5.0 2.0 1.0 0.8 0.6 0.4 -10.0 4 3.0 -0.8 0.2 -0.2 Swp Max 1995MHz 0.2 10.0 0.2 1980 4.0 5.0 0.2 0. 4 4. 0 5.0 0.8 0. 6 1.0 0.8 0. 6 2. 0 4 0 1960 Antenna Impedance in Downlink Band Swp Max 1995MHz 0 3. Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint 1940 Frequency (MHz) Downlink Impedance in Downlnk Band . -0 1920 0.4 4000 -3 .0 3000 -4. 0 -5.0 2000 -10.0 1000 0. 0 Swp Min 1930MHz Disclaimer: Subject to change without notice www.triquint.com TQM963001 BC14 / B25 BAW Duplexer Uplink Performance Plots - TQM963001-PCB Temp=25C Uplink Antenna Narrowband Response Uplink Antenna Pass Band 0 0 -10 -1 |S21| (dB) |S21| (dB) -20 -30 -40 -2 -3 -50 -4 -60 -70 -5 1800 1850 1900 1950 2000 2050 2100 1830 1850 1870 Frequency (MHz) 1890 1910 1930 1910 1930 Frequency (MHz) Uplink Antenna Wideband Response Uplink Return Loss 0 0 -10 -5 |S11| (dB) |S21| (dB) -20 -30 -40 -10 -15 -50 -20 -60 -25 -70 3000 4000 5000 6000 7000 1830 8000 1850 1870 -10.0 Swp Min 1850MHz - 6 of 9 - 1.0 2. 0 1.0 .0 -2 -1.0 -1.0 -0.8 4 - 0. 6 .0 -2 . -0 -0.8 -3 .0 6 0.8 -0.2 - 4. 0 -5.0 - 0. 0.6 0 10.0 3.0 4.0 5.0 2.0 1.0 0.8 0.6 0.4 0.2 10.0 0.4 0.2 Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint 0.8 0. 6 0.2 4 4.0 5.0 0.2 4 10.0 -0.2 0 3. -10.0 0. 4. 0 5.0 -3 .0 1.0 3.0 Swp Max 1915MHz -4. 0 -5.0 0.8 2. 0 4 0 Antenna Impedance in Uplink Band Swp Max 1915MHz 0. 0. 6 Uplink Impedance in Uplink Band . -0 1890 Frequency (MHz) Frequency (MHz) 10.0 2000 3.0 4.0 5.0 1000 2.0 0 Swp Min 1850MHz Disclaimer: Subject to change without notice www.triquint.com TQM963001 BC14 / B25 BAW Duplexer Isolation/Antenna Return Loss - TQM963001-PCB Temp=25C Pin Configuration and Description GND GND Ant GND 7 6 5 8 1 2 3 DL GND UL Pin No. 1 Symbol DL Description Downlink input 3 UL Uplink output 6 Ant Antenna port 8 GND (i GND 2, 4, 5, 7, Center Pad Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint l 4 GND Internally connected to ground, but no external connection required. RF ground - 7 of 9 - Disclaimer: Subject to change without notice www.triquint.com TQM963001 BC14 / B25 BAW Duplexer Mechanical Information Package Marking and Dimensions Marking: Part number - 3001 Lot Code - XXXX Pin 1 Indicator 3001 XXXX Center Pad UL DL NOTES: 1. All dimensions are in millimeters. Angles are in degrees. 2. Except where noted, this part outline conforms to JEDEC standard MO-220, Issue E (Variation VGGC) for thermally enhanced plastic very thin fine pitch quad flat no lead package (QFN). 3. Dimension and tolerance formats conform to ASME Y14.4M-1994. 4. The terminal #1 identifier and terminal numbering conform to JESD 95-1 SPP-012. PCB Mounting Pattern NOTES: 1. All dimensions are in millimeters. Angles are in degrees. 2. Use 1 oz. copper minimum for top and bottom layer metal. 3. Vias are required under the TBD of this device for proper RF/DC grounding and thermal dissipation. We recommend a 0.35mm (#80/.0135") diameter bit for drilling via holes and a final plated thru diameter of 0.25 mm (0.10"). 4. Ensure good package backside paddle solder attach for reliable operation and best electrical performance. Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint - 8 of 9 - Disclaimer: Subject to change without notice www.triquint.com TQM963001 BC14 / B25 BAW Duplexer Product Compliance Information ESD Sensitivity Ratings Solderability Compatible with both lead-free (260 C max. reflow temperature) and tin/lead (245 C max. reflow temperature) soldering processes. Caution! ESD-Sensitive Device Package contact plating: Ni/Au ESD Rating: Value: Test: Standard: Class 1B 500 V to < 1000 V Human Body Model (HBM) ESDA/JEDEC Standard JS-001-2012 ESD Rating: Value: Test: Standard: Class B > 200 V to < 400 V Machine Model (MM) JEDEC Standard JESD22-A115-A RoHs Compliance This part is compliant with EU 2002/95/EC RoHS directive (Restrictions on the Use of Certain Hazardous Substances in Electrical and Electronic Equipment). This product also has the following attributes: Lead Free Halogen Free (Chlorine, Bromine) Antimony Free TBBP-A (C15H12Br402) Free PFOS Free SVHC Free MSL Rating MSL Rating: Level 3 Test: 260 C convection reflow Standard: JEDEC Standard IPC/JEDEC J-STD-020 Contact Information For the latest specifications, additional product information, worldwide sales and distribution locations, and information about TriQuint: Web: www.triquint.com Email: info-sales@triquint.com Tel: Fax: +1.407.886.8860 +1.407.886.7061 For technical questions and application information: Email: sjcapplications.engineering@triquint.com Important Notice The information contained herein is believed to be reliable. TriQuint makes no warranties regarding the information contained herein. TriQuint assumes no responsibility or liability whatsoever for any of the information contained herein. TriQuint assumes no responsibility or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for TriQuint products. The information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by such information. TriQuint products are not warranted or authorized for use as critical components in medical, life-saving, or lifesustaining applications, or other applications where a failure would reasonably be expected to cause severe personal injury or death. Datasheet: Rev. D 05-19-14 (c) 2014 TriQuint - 9 of 9 - Disclaimer: Subject to change without notice www.triquint.com