R High Current Density CompactPCI Power Data Sheet Power-One's CompactPCI(R) Power Solutions Provide Extremely-High Current Densities Overview (R) Power-One's CompactPCI power solutions are (R) fully compliant to the PICMG 2.11 Power Interface Specification using a standard TM Positronic 47-pin connector. Patented EDGE Technology provides very high output current capacities. At 50C the 3U units deliver 40 amps on both the +5 and +3.3 volt outputs, and the 6U unit delivers 50 and 60 amps, respectively. Features High current density in industry-standard packages. Wide range AC or DC input. DC input 36-75 VDC AC input 90-264 VAC with PFC High output power. 3U x 8HP 200 and 250 Watts 6U x 8HP 500 Watts Remote sense and active current share on the +5, +3.3, and +12 volt outputs, along with internal ORing FETs, allow these units to be used in redundant, hot-swap applications. (R) Power-One's CompactPCI models meet international safety standards and display the CE Mark for the Low Voltage Directive. High current on +3.3 and +5 volt outputs. Single-wire active current share and remote sense on +5, +3.3, and +12 volt outputs. Overtemperature, overvoltage, and overcurrent protection. Input Good and Power Supply Fault LED indicators. Inhibit and Enable inputs. CompactPCI and PICMG are registered trademarks of the PCI Industrial Computer Manufacturers Group. The Power-One logo and EDGE are trademarks of Power-One, Inc. REV. AUG 15, 2003 Page 1 of 7 R High Current Density CompactPCI Power Data Sheet Model Selection Model Power Height Input (Watts) Profile Voltage +5V Current +3.3V Current +12V Current -12V Current CPA200-4530 200 3U 90-264 VAC 40 A 40 A 5.5 A 2A CPD200-4530 200 3U 36-75 VDC 40 A 40 A 5.5 A 2A CPA250-4530 250 3U 90-264 VAC 40 A 40 A 5.5 A 2A CPD250-4530 250 3U 36-75 VDC 40 A 40 A 5.5 A 2A CPA500-4530 500 6U 90-264 VAC 50 A 60 A 12 A 4A The Only CompactPCI (R) TM Power Solutions with EDGE Technology TM Power-One's Efficient Dual Geometric Edge (EDGE ) Technology facilitates high current densities, increases reliability by reducing component stresses, and decreases the amount of heat dissipated from the power supply into your system. The backbone of this patented technology is an interleaved, multi-channel forward converter utilizing transitional resonant switching techniques, and proprietary TM leading and trailing edge pulsewidth modulation. EDGE technology has a proven track record in high-availability power solutions such as Power-One's Net Series. Green LED indicating input OK Hot-swappable 47-pin Positronic connector I2C Intelligent Platform Management Interface (IPMI) signal compatibility * Single-wire Current Share on +3.3, +5, and +12V outputs Remote Sense on +3.3, +5, and +12V outputs PICMG compliant ejector Inhibit and Enable signal inputs * Consult factory for model specific availability. QUICK EVALUATION DELIVERY (QED) PRODUCTS These latest technology products are readily available at Power-One, or your local distributor, to quickly get power to your prototype system. In addition to fast delivery, Power-One's QED solutions provide industry-leading current and power densities. REV. AUG 15, 2003 Page 2 of 7 Red LED indicating fault condition R High Current Density CompactPCI Power Data Sheet A Power Solution as Flexible as CompactPCI(R) Power-One's CompactPCI(R) power solutions provide high currents on the 3.3V and 5V outputs and offer the flexibility of being able to simultaneously load these two outputs until their combined power equals the total rated wattage of the power supply. This provides greater flexibility to support the dynamic loading requirements of your current system and allows for system migration between voltages for future configurations. Power-One will also be providing migration paths for communications protocols and applications. Communications protocol development plans include the I2C bus Intelligent Platform Management Interface. Applications specific development plans include 24V input CompactPCI(R) power solutions for wireless communication applications. Extremely high current densities; 3U high units provide up to 40 amps on 3.3V and 5V outputs. The 6U unit provides 3.3V @ 60A and 5V @ 50A. AC (with PFC) and DC input versions available Patented EDGE Technology provides efficiencies of over 80% Fully compliant to PICMG 2.11 Power Interface Specification EMI gasket facilitates compliance to system-level EMI requirements Comprehensive International regulatory agency compliances Full rated output available at 50C with 400 LFM cooling REV. AUG 15, 2003 Page 3 of 7 R High Current Density CompactPCI Power Data Sheet CPD DC/DC Series Specifications Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - DC Hold-up Time Input Current Input Protection Inrush Surge Current Operating Frequency Input Transient Protection Continuous input range. From 48 VDC Input. At full rated load; 36 VDC, 48 VDC. Non-user serviceable, internally-located input line fuse. Internally limited by thermistor and electronic switch. Switching frequency of main output transformer. Varistor. 36 4 NOM MAX UNITS 75 VDC ms A 12 145 A kHz MAX UNITS 7.6, 5.4 125 Output Specifications PARAMETER CONDITIONS/DESCRIPTION Efficiency Minimum Load; V1, V2, V3 Minimum Load, V3 Ripple and Noise Full rated load, 48 VDC Input. Minimum load required to maintain regulation with no load on V4. Minimum load on V3 required to maintain regulation on V4. Full load, 20 MHz bandwidth. +5 and +3.3V. +12 and -12V CPD200-4530 with 250 LFM forced-air cooling. CPD250-4530 with 400 LFM forced-air cooling. Output voltage overshoot/undershoot at turn-on. Line changes over the specified input range. Changes in load starting at 50% load and changing to 100% load; V1, V2, V3. V4 has droop regulation for passive current sharing. Time required for initial output voltage stabilization. Output Power Overshoot /Undershoot Regulation Turn-on Delay Initial Setting Accuracy MIN NOM 80 % A A None 75% of V4 Load 2 1.3 200 250 0 0.5 1 4 150 1 % W % % ms % Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. With 250 LFM for CPD200 and 400 LFM for CPD250 forced-air cooling At 100% load: Derate linearly above 50C by 2.5% per C. At 50% load: Operating Temperature Storage Temperature Relative Humidity Shock Vibration MIN Non-Condensing. Peak acceleration. Random vibration, 10 Hz to 2 kHz, 3 axis. NOM 0 -40 5 MAX UNITS 10k 40k 50 70 85 95 20 6 ASL Ft. C C %RH GPK GRMS Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Overload Protection Latch style overvoltage protection. 120 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. TTL compatible signal, open collector active low signal. Indicates any output below 90% and/or a low input <36VDC. Accuracy of shared current with up to 6 parallel units. Single wire current share on V1, V2, and V3. V4 has passive droop current sharing. Available on V1, V2, and V3. Total voltage compensation for cable losses with respect to the main output. TTL-compatible signal inhibited with GND or TTL "0". Contact closure to external ground to start unit. On shortest pin (last make, first break). (DEG#) Provides warning when power supply temperature is within 20 degrees C of derating point. TTL-compatible open. Input OK (Green), Output Failure (Red). Overtemperature Protection Power Fail (FAL#) Current Share Remote Sense Inhibit (INH#) Enable (EN#) Overtemperature Warning Front Panel LED Status Indicators MIN REV. AUG 15, 2003 Page 4 of 7 NOM MAX UNITS 130 %Vnom 10 % 150 mV R High Current Density CompactPCI Power Data Sheet CPD DC/DC Series Specifications Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals ESD Susceptibility Radiated Susceptibility EFT/Burst Input Surge UL1950. cUL1950. EN60950 (TUV). Input to Output per EN60950. EN55022 / CISPR 22 Conducted. Radiated. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, level 3. Conducted Disturbance Insulation Resistance Per EN61000-4-6, level 2. Input-to-Output. Dielectric Withstand Voltage Electromagnetic Interference MIN NOM MAX UNITS Approved Line to Line Line to Ground 2120 A A 8 10 2 1 2 VDC Class kV V/M kV kV 3 10 V M CPD Pin Allocation PIN PIN-LENGTH TYPE (NOTE 1) SIGNAL NAME DESCRIPTION PIN PIN-LENGTH TYPE (NOTE 1) SIGNAL NAME DESCRIPTION 1-4 5-12 13-18 19 20 21 22 23 24 25 26 27 28 29 30 31 M M M M M M M M M M M S M M M M V1 RTN V2 RTN V3 V4 RTN RESERVED RTN NC RESERVED EN# NC NC V1SENSE NC V1 Output V1 and V2 Return V2 Output V3 RETURN V3 Output V4 Output Signal Return Reserved V4 Return Not Connected Reserved Enable Not Connected Not Connected V1 Remote Sense Not Connected 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 M M M M M M M M M M M M M L M M NC V2 SENSE S RTN V1SHARE V3SENSE NC DEG# INH# NC V2SHARE FAL# NC V3SHARE CGND +DCIN -DCIN Not Connected V2 Remote Sense Sense Return V1 Current Share V3 Remote Sense Not Connected Degrade Signal Inhibit Not Connected V2 Current Share Fail Signal Not Connected V3 Current Share Chassis Ground + DC Input - DC Input NOTE 1) L = Long-Length Pins, M = Medium-Length Pins, S= Short-Length Pins NUCLEAR AND MEDICAL APPLICATIONS- Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS- The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. AUG 15, 2003 Page 5 of 7 R High Current Density CompactPCI Power Data Sheet CPA AC/DC Series Specifications Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - AC Input Frequency Hold-up Time Input Protection Inrush Surge Current Power Factor Operating Frequency Input Transient Protection Continuous input range. 90 47 20 Non-user serviceable, internally-located input line fuse. Internally limited by thermistor and electronic switch. Meets EN61000-3-2. Switching frequency of main output transformer. Varistor. NOM 0.95 125 MAX UNITS 264 63 VAC Hz ms 15 145 A W/VA kHz MAX UNITS Output Specifications PARAMETER CONDITIONS/DESCRIPTION Efficiency Minimum Load; V1, V2, V3 Minimum Load, V3 Ripple and Noise Full rated load, 115/230 VAC Input. Minimum load required to maintain regulation with no load on V4. Minimum load on V3 required to maintain regulation on V4. Full load, 20 MHz bandwidth. +5 and +3.3V. +12 and -12V CPA200-4530 with 250 LFM forced-air cooling. CPA250-4530 with 400 LFM forced-air cooling. CPA500-4530 with 400 LFM forced-air cooling. Output voltage overshoot/undershoot at turn-on. Line changes over the specified input range. Changes in load starting at 50% load and changing to 100% load; V1, V2, V3. V4 has droop regulation for passive current sharing. Time required for initial output voltage stabilization. Output Power Overshoot /Undershoot Regulation Turn-on Delay Initial Setting Accuracy MIN NOM 80 % A A None 75% of V4 Load 2 1.3 200 250 500 0 0.5 1 4 150 1 % W % % ms % Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. With 250 LFM for CPA200, 400 LFM for CPA250, and 400 LFM for CPA500 forced-air cooling Derate linearly above 50C by 2.5% per C. Operating Temperature Storage Temperature Relative Humidity Shock Vibration MIN Non-Condensing. Peak acceleration. Random vibration, 10 Hz to 2 kHz, 3 axis. At 100% load: At 50% load: 0 -40 5 NOM MAX UNITS 10k 40k ASL Ft. 50 70 85 95 20 6 C C %RH GPK GRMS NUCLEAR AND MEDICAL APPLICATIONS- Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS- The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. AUG 15, 2003 Page 6 of 7 R High Current Density CompactPCI Power Data Sheet CPA AC/DC Series Specifications Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Overload Protection Latch style overvoltage protection. 120 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. TTL compatible signal, open collector active low signal. Indicates any output below 90% and/or a low input <90VAC. Accuracy of shared current with up to 6 parallel units. Single wire current share on V1, V2, and V3. V4 has passive droop current sharing. Available on V1, V2, and V3. Total voltage compensation for cable losses with respect to the main output. TTL-compatible signal inhibited with GND or TTL "0". Contact closure to external ground to start unit. On shortest pin (last make, first break). (DEG#) Provides warning when power supply temperature is within 20 degrees C of derating point. TTL-compatible open. Input OK (Green), Output Failure (Red). Overtemperature Protection Power Fail (FAL#) Current Share Remote Sense Inhibit (INH#) Enable (EN#) Overtemperature Warning Front Panel LED Status Indicators MIN NOM MAX UNITS 130 %Vnom 10 % 150 mV MAX UNITS Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals ESD Susceptibility Radiated Susceptibility EFT/Burst Input Surge UL1950. cUL1950. EN60950 (TUV). Input to Output per EN60950. EN55022 / CISPR 22 Conducted. Radiated. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, level 3. Conducted Disturbance Insulation Resistance Per EN61000-4-6, level 2. Input-to-Output. Dielectric Withstand Voltage Electromagnetic Interference MIN NOM Approved Line-to-Line Line-to-Ground 4243 A A 8 10 2 1 2 VDC Class kV V/M kV kV 3 10 CPA Pin Allocation PIN PIN-LENGTH TYPE (NOTE 1) SIGNAL NAME DESCRIPTION PIN PIN-LENGTH TYPE (NOTE 1) SIGNAL NAME DESCRIPTION 1-4 5-12 13-18 19 20 21 22 23 24 25 26 27 28 29 30 31 M M M M M M M M M M M S M M M M V1 RTN V2 RTN V3 V4 RTN RESERVED RTN NC RESERVED EN# NC NC V1SENSE NC V1 Output V1 and V2 Return V2 Output V3 RETURN V3 Output V4 Output Signal Return Reserved V4 Return Not Connected Reserved Enable Not Connected Not Connected V1 Remote Sense Not Connected 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 M M M M M M M M M M M M M L M M NC V2 SENSE S RTN V1SHARE V3SENSE NC DEG# INH# NC V2SHARE FAL# NC V3SHARE CGND ACN ACL Not Connected V2 Remote Sense Sense Return V1 Current Share V3 Remote Sense Not Connected Degrade Signal Inhibit Not Connected V2 Current Share Fail Signal Not Connected V3 Current Share Chassis Ground AC Input Neutral AC Input Line NOTE 1) L = Long-Length Pins, M = Medium-Length Pins, S= Short-Length Pins REV. AUG 15, 2003 Page 7 of 7 V M