Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - DC Continuous input range. 36 75 VDC
Hold-up Time From 48 VDC Input. 4 ms
Input Current At full rated load; 36 VDC, 48 VDC. 7.6, 5.4 A
Input Protection Non-user serviceable, internally-located input line fuse.
Inrush Surge Current Internally limited by thermistor and electronic switch. 12 A
Operating Frequency Switching frequency of main output transformer. 125 145 kHz
Input Transient Protection Varistor.
CPD DC/DC Series Specifications
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full rated load, 48 VDC Input. 80 %
Minimum Load; V1, V2, V3 Minimum load required to maintain regulation with no load on V4. None A
Minimum Load, V3 Minimum load on V3 required to maintain regulation on V4. 75% of V4 Load A
Ripple and Noise Full load, 20 MHz bandwidth.
+5 and +3.3V. 2%
+12 and -12V 1.3
Output Power CPD200-4530 with 250 LFM forced-air cooling. 200
CPD250-4530 with 400 LFM forced-air cooling. 250 W
Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on. 0 %
Regulation Line changes over the specified input range. 0.5
%
Changes in load starting at 50% load and changing to 100% load; V1, V2, V3. 1
V4 has droop regulation for passive current sharing. 4
Turn-on Delay Time required for initial output voltage stabilization. 150 ms
Initial Setting Accuracy ±1%
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating. 10k ASL Ft.
Non-Operating. 40k
Operating Temperature With 250 LFM for CPD200 and 400 LFM for CPD250 forced-air cooling At 100% load: 0 50 °C
Derate linearly above 50°C by 2.5% per °C. At 50% load: 70
Storage Temperature -40 85 °C
Relative Humidity Non-Condensing. 5 95 %RH
Shock Peak acceleration. 20 GPK
Vibration Random vibration, 10 Hz to 2 kHz, 3 axis. 6 GRMS
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection Latch style overvoltage protection. 120 130 %Vnom
Overload Protection Fully protected against output overload and short circuit. Automatic recovery
upon removal of overload condition.
Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset.
Power Fail (FAL#) TTL compatible signal, open collector active low signal. Indicates any output below
90% and/or a low input <36VDC.
Current Share Accuracy of shared current with up to 6 parallel units. Single wire current share
on V1, V2, and V3. 10 %
V4 has passive droop current sharing.
Remote Sense Available on V1, V2, and V3. Total voltage compensation for cable losses with 150 mV
respect to the main output.
Inhibit (INH#) TTL-compatible signal inhibited with GND or TTL "0".
Enable (EN#) Contact closure to external ground to start unit. On shortest pin (last make, first break).
Overtemperature Warning (DEG#) Provides warning when power supply temperature is within 20 degrees C of
derating point. TTL-compatible open.
Front Panel LED Input OK (Green), Output Failure (Red).
Status Indicators
Page 4 of 7
High Current Density CompactPCI Power Data Sheet