NLP65 Series Data Sheet
Output
Voltage
Output Current Ripple(4) Total
Regulation(6)
Non-Harmonic
Corrected
Harmonic
Corrected
Ground
Pin (12, 14, 17)
Max(1) Peak(3) Fan(10)
+5 V (IA) 7.5 A 9.1 A 8 A 50 mV ±2.0% NLP65-7608J NLP65-9608J(a) NLP65-X608GJ
+12 V (IB) 2.5 A 3.3 A 3 A 150 mV ±5.0%
–12 V 0.65 A 0.81 A 0.8 A 120 mV ±5.0%
+5 V (IA) 7.5 A 9.1 A 8 A 50 mV ±2.0% NLP65-7610J NLP65-9610J NLP65-X610GJ
+15 V (IB) 2.2 A 2.9 A 2.5 A 150 mV ±5.0%
–15 V 0.65 A 0.85 A 0.8 A 150 mV ±5.0%
+5 V 7.0 A 9.1 A 8.0 A 50 mV ±2.0% NLP65-3322J(15)
+24 V 1.5 A 2.6 A 2.0 A 240 mV ±5.0%
+12 V 0.7 A 1.0 A 1.0 A 120 mV ±5.0%
+5 V (IA) 7 A 9.1 A 8 A 50 mV ±2.0% NLP65-7620J NLP65-9620J NLP65-X620GJ
+24 V (IB) 2 A 2.6 A 2 A 240 mV ±5.0%
+5 V (IA) 7 A 9.1 A 8 A 50 mV ±2.0% NLP65-7629J NLP65-9629J NLP65-X629GJ
+12 V (IB) 2.5 A 3.3 A 3 A 150 mV ±5.0%
+5 V 10 A 13 A 12 A 50 mV ±2.0% NLP65-7605J NLP65-9605J NLP65-X605GJ
+12 V 5.4 A 7 A 6.5 A 120 mV ±2.0% NLP65-7612J NLP65-9612J NLP65-X612GJ
+24 V 2.7 A 3.5 A 3.5 A 240 mV ±2.0% NLP65-7624J NLP65-9624J NLP65-X624GJ
Notes
1. Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65-X610J must not exceed 62.5 Watts continuous output power with
natural convection. Model NLP65-X620J not to exceed 65 Watts continuous output power with natural convection. Model NLP65-3322J must
not exceed 60 Watts continuous output power with natural convection.
2. When the input voltage is less than 90 Vac the operating temperature range is 0 °C to +40 °C. The ripple and regulation specifications may not
be met.
3. Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation
limits.
4. Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor.
5. Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz.
6. A minimum load on the main output is required for proper start up. For multiple outputs and single +5V output, the minimum load on the +5 V is
0.2 A. For single outputs greater than +5 V the minimum load is 0.1 A. To maintain stated regulation then:
for single output units
I ≥ 0.2 A
for multiple output units
0.25≤I(A)/I(B)≤ 5, for I(A) ≥ 0.2 A.
7. For optimum reliability, no part of the heatsink should exceed 120 °C, and no semiconductor case temperature should exceed 130 °C.
8. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements.
9. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated
as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and
System Integrators, including through Distribution Channels. It is not intended for sale to End Users.
10. Maximum continuous output power for all multiple output models must not exceed 75 Watts (70 watts for NLP65-3322J) with 20 CFM forced
air cooling.