POWER
NLP65 Series
Single, Dual and Triple Output
Total Power: 65 - 75 W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc*
# of Outputs: Single, dual, triple
SPECIAL FEATURES
Universal input
3” x 5” footprint
Low prole ts 1U applications
EN61000-3-2 compliance option (HCC)
Overvoltage and short circuit protection
65 W with free air convection cooling
EN55022, EN55011 conducted
emissions level B
EN61000-4-2,-3,-4, -5, -6
immunity compliant
RoHS compliant
LPX80 enclosure kit available
Two year warranty
SAFETY
VDE0805/EN60950-1
File No. 1040100-3336-0096
License No. 114404
UL 60950-1
cUL 60950-1
CCC 60950-1
CE LVD Directive
*NLP65-76xx version only
Electrical Specications
Input
Input voltage range Universal input (see Note 2)
NLP65-76xx version only
85 - 264 Vac
120 - 370 Vdc
Input frequency range 47 - 63 Hz
Input current
(cold start)
120 Vac
230 Vac
17 A max.
32 A max
Safety ground leakage current 120 Vac, 60 Hz
230 Vac, 50 Hz
0.7 mA
1.4 mA
Input current
120 Vac, with PFC
230 Vac, with PFC
120 Vac, without PFC
230 Vac, without PFC
1.4 A
0.51 A rms
1.40 A rms
0.80 A rms
Input fuse UL/IEC127 5 A, 250 Vac In live and neutral
Output
Total regulation
(line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Rise time At turn-on 1.0 s, max
Transient response
Main output
25% step
at 0.1 A/µs
5.0% or 250 mV
max. dev., 1ms max.
recovery to 1%
Temperature coefficient ±0.02%/°C
Overvoltage protection Main outputs 125%, ±10%
Short circuit protection Cyclic operation Continuous
Minimum output current Single and multiple (See Note 6)
Data Sheet
NLP65 Series Data Sheet
EMC Charateristics (11, 12)
Conducted emissions EN55022, FCC part 15 Level B
ESD air EN61000-4-2, level 3 Perf. criteria 1
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity EN61000-4-6, level 3 Perf. criteria 2
General Specications
Hold-up time 120 Vac, 60 Hz
230 Vac, 50 Hz
16 ms @ 65 W
78 ms @ 65 W
Efficiency 120 Vac, 65 W 72% typical
Isolation voltage Input/output
Input/chassis
3000 Vac
1500 Vac
Switching frequency Fixed 100 kHz, ±5 kHz
Approvals and standards
(see Notes 9, 13)
EN60950-1, IEC60950-1
Weight 283 g (10 oz)
MTBF demonstrated MIL-HDBK-217F 150,000 hours min
Environmental Specications
Thermal performance: Operating (See derating curve) 0° C to +70 °C
(See notes 1, 3, 10) Non-operating -40 °C to +85 °C
50 °C - 70 °C ambient, convection cooled Derate to 50% load
0 °C to 50 °C, ambient, convection cooled 65 W
0 °C to 50 °C, ambient 20CFM forced air (See Note 10) 75 W
Peak (0 °C to 50 °C, 60 s) See table
Relative humidity Non-condensing 5 to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 5) 5-500 Hz 2.4 G rms peak
Shock per MIL-STD-810E 516.4 Part IV
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
NLP65 Series Data Sheet
Output
Voltage
Output Current Ripple(4) Total
Regulation(6)
Non-Harmonic
Corrected
Harmonic
Corrected
Ground
Pin (12, 14, 17)
Max(1) Peak(3) Fan(10)
+5 V (IA) 7.5 A 9.1 A 8 A 50 mV ±2.0% NLP65-7608J NLP65-9608J(a) NLP65-X608GJ
+12 V (IB) 2.5 A 3.3 A 3 A 150 mV ±5.0%
–12 V 0.65 A 0.81 A 0.8 A 120 mV ±5.0%
+5 V (IA) 7.5 A 9.1 A 8 A 50 mV ±2.0% NLP65-7610J NLP65-9610J NLP65-X610GJ
+15 V (IB) 2.2 A 2.9 A 2.5 A 150 mV ±5.0%
–15 V 0.65 A 0.85 A 0.8 A 150 mV ±5.0%
+5 V 7.0 A 9.1 A 8.0 A 50 mV ±2.0% NLP65-3322J(15)
+24 V 1.5 A 2.6 A 2.0 A 240 mV ±5.0%
+12 V 0.7 A 1.0 A 1.0 A 120 mV ±5.0%
+5 V (IA) 7 A 9.1 A 8 A 50 mV ±2.0% NLP65-7620J NLP65-9620J NLP65-X620GJ
+24 V (IB) 2 A 2.6 A 2 A 240 mV ±5.0%
+5 V (IA) 7 A 9.1 A 8 A 50 mV ±2.0% NLP65-7629J NLP65-9629J NLP65-X629GJ
+12 V (IB) 2.5 A 3.3 A 3 A 150 mV ±5.0%
+5 V 10 A 13 A 12 A 50 mV ±2.0% NLP65-7605J NLP65-9605J NLP65-X605GJ
+12 V 5.4 A 7 A 6.5 A 120 mV ±2.0% NLP65-7612J NLP65-9612J NLP65-X612GJ
+24 V 2.7 A 3.5 A 3.5 A 240 mV ±2.0% NLP65-7624J NLP65-9624J NLP65-X624GJ
Notes
1. Natural convection cooling. Models NLP65-X629J, NLP65-X608J, NLP65-X610J must not exceed 62.5 Watts continuous output power with
natural convection. Model NLP65-X620J not to exceed 65 Watts continuous output power with natural convection. Model NLP65-3322J must
not exceed 60 Watts continuous output power with natural convection.
2. When the input voltage is less than 90 Vac the operating temperature range is 0 °C to +40 °C. The ripple and regulation specifications may not
be met.
3. Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total regulation
limits.
4. Figure is peak-to-peak for convection power rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF ceramic capacitor.
5. Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz.
6. A minimum load on the main output is required for proper start up. For multiple outputs and single +5V output, the minimum load on the +5 V is
0.2 A. For single outputs greater than +5 V the minimum load is 0.1 A. To maintain stated regulation then:
for single output units
I ≥ 0.2 A
for multiple output units
0.25≤I(A)/I(B)≤ 5, for I(A) ≥ 0.2 A.
7. For optimum reliability, no part of the heatsink should exceed 120 °C, and no semiconductor case temperature should exceed 130 °C.
8. CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements.
9. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated
as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and
System Integrators, including through Distribution Channels. It is not intended for sale to End Users.
10. Maximum continuous output power for all multiple output models must not exceed 75 Watts (70 watts for NLP65-3322J) with 20 CFM forced
air cooling.
NLP65 Series Data Sheet
11. Conducted emissions testing were performed using the standard EN55022 set-up with a stand alone NLP65 unit placed on a grounded metal
plate with a line choke on the AC input and ground wires (i.e. the wires are looped through an EMI suppression toroid).
For system compliance it is usually necessary to install an ‘off-the-shelf’ AC inlet with an integral line filter in the system chassis or to install a
line choke on the input wires as close as possible to AC entry point of the system chasssis. Please contact the applications group for assis-
tance with EMI compliance.
12. The NLP65 units with the suffix ‘G’ is the ground pin and ground choke option. J2, L6 and JP10 are included. J2 is a safety agency approved
grounding pin, L6 is a ground choke and JP10 is a jumper. This option is intended for use in non-metallic chassis applications where grounding
is not possible via the mounting screws. The ground choke is provided to assist system EMC compliance. When performing conducted
emissions testing on stand alone units, the ‘G’ option is required to meet level B. To order simply add the suffix ‘G’ to the standard model
number, e.g. NLP65-7608GJ, NLP65-9608GJ. This option is available for both the PFC and non-PFC versions.
13. All models require a minimum mounting stand-off of 0.25 inches (6.35 mm) in the end use product.
14. The NLP65-9608J is available with an enclosure. To order an enclosed version, use NLP65-9608EJ.
15. No PFC version, EN61000-3-2 is not applicable to this model.
16. The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
17. NOTICE: Some models do not support all options. Please contact your local Artesyn Embedded Technologies representative or use the on-line
model number search tool at http://www.artesyn.com/power
Model Numbering Options
a) The enclosure version NLP65-9608EJ includes: IEC connector, on/off switch, wire harness output connector and fitted cover. To order, please
add the suffix ‘E’ the model number. See NLP65 enclosure for details.
b) A Safety earth ground pin and ground choke are available as an option.
To order, please add the suffix ‘G’ the model number, e.g. NLP65-X608GJ.
c) To order an enclosure kit (unfitted), order the part number LPX80.
Mechanical Drawing
C19
ALL DIMENSIONSIN INCHES (mm)
5.00
(127.00)
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
N1
1
J3
J1
J2
6
4.550
(115.57)
2.550
(64.770)
TOLERANCE: .xxx 0.005"
.xx 0.02"
0.225
(5.715)
3.00
(76.20)
3
Mounting
Hole Diameter
0.156 (4.00)
T
T1
T1
L
NLP65 Series Data Sheet
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
NLP65 Series-DS 21Mar2016
Input Pin Connections
J1
Pin 1 AC Line
Pin 2 No Pin
Pin 3 AC Neutral
J2 (On ‘G’ Sufc Only)
Pin 1 Safety Ground
Input and Output Connectors Mating Connectors
AC (J1) Molex 26-60-4030 type or equivalent Molex 09-50-3031 or equivalent with Molex 08-52-0113 or equivalent crimp terminals
DC (J3) Molex 26-60-4060 or equivalent Molex 09-50-3061 with Molex 2478 phosphor bronze crimp terminals or equivalent.
Output Pin Connections
J3 SINGLE DUAL TRIPLE
Pin 1 V (A) V (B) V (B)
Pin 2 V (A) V (A) V (A)
Pin 3 V (A) V (A) V (A)
Pin 4 Return Return Return
Pin 5 Return Return Return
Pin 6 Return N/C V (C)