http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load 12 Vin models: 30 mA typ.
24 Vin models: 20 mA typ.
48 Vin models: 10 mA typ.
Input current (full load) 12 Vin; 3.3 Vout models: 1050 mA typ.
12 Vin; other output models: 1500 mA typ.
24 Vin; 3.3 Vout models: 550 mA typ.
24 Vin; other output models: 750 mA typ.
48 Vin; 3.3 Vout models: 250 mA typ.
48 Vin; other output models: 350 mA typ.
Start-up voltage / under voltage shut down 12 Vin models: 8.5 VDC / 8.0 VDC typ.
24 Vin models: 17 VDC / 15 VDC typ.
48 Vin models: 33 VDC / 29 VDC typ.
Surge voltage 12 Vin models: 25 V max.
(100 msec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Output Specifications
Voltage set accuracy ±1 %
Regulation – Input variation Vin min. to Vin max. 1 % max.
– Load variation 10 – 100 % single output models: 0.5 % max.
dual output models balanced load: 1 % max.
dual output models unbalanced load: 3 % max. / Minimum load 10 %
Ripple and noise (20 MHz Bandwidth) single output models: 50 mVpk-pk max.
dual output models: 75 mVpk-pk max
Temperature coefficient ±0.02 %/K
Output current limitation >120 % of Iout max., foldback
Short circuit protection indefinite (automatic recovery)
Capacitive load single output models: 470 µF max.
dual output models: 220 µF max. (per output)
General Specifications
Temperature ranges – Operating –40°C to +80°C (without load derating)
– Case temperature +100°C max.
– Storage –55°C to +125°C
Power derating – Natural convection 2.5 %/K above +60°C
– Natural convection with heat sink (optional) 1.0 %/K above +70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >700’000 h
Isolation voltage (60 sec.) – Input/Output 1500 VDC
Isolation capacitance – Input/Output 1200 pF typ.
Isolation resistance – Input/Output (500 VDC) >1000 M Ohm
Switching frequency (fixed) 330 kHz typ. (Pulse width modulation PWM)
Safety standards UL/cUL 60950-1, IEC/EN 60950-1
(Compliance up to 60 VDC input voltage
(SELV limit)
Environmental compliance – Reach
www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
DC/DC Converters
TEL 15 Series 15 Watt