www.osram-americas.com/LED LINEARlight FLEX(R) Accessories LED Modules Key Features & Benefits ---- Easy assembly without soldering wires ---- Assembly without tools ---- Reduced assembly time ---- Highly shock resistant ---- Part of the UL2108 Listed System These accessories simplify the installation process of the LINEARlight FLEX modules by eliminating the need to solder wires and provides an easy to use track system. The use of these accessories is required when installing a UL2108 Listed System. Accessories Compatible with the following LINEARlight FLEX products: Indoor Outdoor POWER FLEX Advanced Short Pitch Colormix POWER FLEX Protect Advanced Protect Colormix Protect Application Information Applications Technical Features ---- Connect system for LINEARlight FLEX modules ---- Input Connector for connection of module to power supply ---- Termination Cap for additional cutting possibilities ---- Board to Board Connector for connection of one board to another with the total strip length up to 1 full reel ---- Allowed operating temperature suited to all LINEARlight FLEX products ---- Backside of Termination Cap is self-adhesive LED142R2 7-15 Ordering Information Item Number Ordering Abbreviation European Part Description Length (in.) Case Qty. Track Accessories 72356 LAC-T/STS/7FT LF-LTS-2100 6.9' aluminium track 83 40 72357 LAC-M/STS/CLIP LF-LTS-MB Optional mounting bracket for track 1.1 280 72360 LAC-T/STS-COV/C/7FT LF-LTS-COVER-CLEAR 6.9' clear cover for track 83 40 72358 LAC-T/STS-COV/D/7FT LF-LTS-COVER-DIFFUSE 6.9' diffused cover for track 83 40 72359 LAC-S/STS/ENDCAP LF-LTS-ENDCAP End cap used only with 72358 0.8 160 72361 LAC-T/STS-COV/SP/7FT LF-LTS-COVER-SHORTPITCH 6.9' diffused cover specifically 83 40 designed for short pitch product 0.4 (9.7) 0.6 (14.7) 13.8 (350) 82.7 (2100) 68.9 (1750) 72356 0.2(4.4) 0.04(1) 0.7(18.8) 72357 1.3(34) 0.4(10) 0.2 (5.3) 0.7 (17.7) 82.7 (2100) 72360 0.9 (24) 0.7 (17.7) 72358 82.7 (2100) 0.8 (20) 0.9 (23.2) 72359 0.8 (20.2) 0.3 (8) 0.4 (10.5) 0.7 (17.7) 82.7 (2100) 72361 Dimensions: inches (mm) Min. Order Qty. 1 35 1 1 20 1 Ordering Information Item Number Ordering Abbreviation European Part Description Length (in.) Case Qty. Min. Order Qty. White Indoor Accessories 71428 LAC-C/TP/TERMCAP LF-2TERM FLEX Termination Cap 200 10 72671 LF-CONN FLEX SC LF-CONN FLEX SC Board to board connector piece 0.35 250 25 72947 LF-WIRE-30 FLEX SC LF-WIRE-30 FLEX SC 30mm connector wire 1.1 10,000 100 72948 LF-WIRE-150 FLEX SC LF-WIRE-150 FLEX SC 150mm connector wire 5.9 5000 50 72946 LF-2PIN Flex SC LF-2PIN Flex SC Input connector 20 250 10 0.6(16.1) 71428 0.5(13.5) 0.2 (6) 0.16 (4.2) 0.2 (6) 0.16 (4.2) 0.2 (6) 72671 0.16 (4.2) 0.3 (8) 0.4 (9.2) 0.3 (8) 0.4 (9.2) 0.3 (8) 0.4 (9.2) 0.3 (8) 1.2 (30) 72947 0.3 (8) 5.9 (150) 72948 0.2 (6) 0.16 (4.2) 0.2 (6) 0.16 (4.2) 0.2 (6) 0.16 (4.2) 0.4 (9.2) 72946 0.4 (9.2) (500) (mm) Dimensions: 19.7 inches 0.4 (9) 19.7 (500) 0.4 (9) 0.4 (9.2) 19.7 (500) 0.4 (9) Ordering Information Item Number Ordering Abbreviation European Part Description Length (in.) Case Qty. Min. Order Qty. Colormix Indoor Accessories - 72618 72670 LF-4PIN FLEX SC LF-4PIN FLEX SC Input connector 20 250 10 72671 LF-CONN FLEX SC LF-CONN FLEX SC Board to board connector piece 0.35 250 10 72947 LF-WIRE-30 FLEX SC LF-WIRE-30 FLEX SC 30mm connector wire 1.1 10,000 100 72948 LF-WIRE-150 FLEX SC LF-WIRE-150 FLEX SC 150mm connector wire 5.9 5000 50 0.2 (6) 0.16 (4.2) 0.2 (6) 0.16 (4.2) 0.2 (6) 0.16 (4.2) 0.4 (9.2) 72670 19.7 (500) 0.4 (9.2) 19.7 (500) 0.4 (9) 0.2(9)(6) 0.4 0.16 (4.2) 0.2 (6) 0.16 (4.2) 0.2 (6) 0.16 (4.2) 0.4 (9.2) 0.3 (8) 0.4 (9.2) 72671 0.3 (8) 0.4 (9.2) 0.3 (8) 0.3 (8) 1.2 (30) 72947 0.3 (8) 5.9 (150) 72948 Dimensions: inches (mm) 0.4 (9.2) 19.7 (500) 0.4 (9) Ordering Information Item Number Ordering Abbreviation European Part Description Length (in.) Case Qty. Min. Order Qty. Colormix Protect Accessories 72362 LAC-C/IP67/ENDCAP LF-ENDCAP PROTECT Used to seal Protect product end when cut 100 10 72363 LF-CLIP-FIXTURE LAC-M/IP67/CLIP Optional flexible mounting bracket 500 50 72365* LAC-C/IP67/IC/4P/20IN LF-4PIN PROTECT IP67 Input connector 20 50 5 72366 LAC-C/IP67/BB/4P/7IN LF-4CONN PROTECT IP67 Board to board connector 7 50 5 *Every Protect module reel comes with one pre-wired input connector and install guide. 0.5 (13.6) 0.4 (9.5) 72362 0.3 (8.4) 0.6 (15.2) 0.2 (5.7) 2 (6) 0.2 (5.7) 1.1 (27) 72363 2 (6) 1.1 (27) 1.2 (30) 20 (506.5) 0.8 (19.8) 18.8 (476.4) 72365 4.7 (120) 0.5 (13.4) 0.7 (18.7) 0.5 (12.7) 7.1 (179.8) 72366 Dimensions: inches (mm) Ordering Information Item Number Ordering Abbreviation European Part Description Length (in.) Case Qty. Min. Order Qty. White Protect Accessories 72667 LF/ENDCAP/IP67/LP LF-ENDCAP IP67 LP Used to seal Protect product end when cut 100 10 72363 LF-CLIP-FIXTURE LAC-M/IP67/CLIP Optional flexible mounting bracket 500 50 72669* LF/2PIN/IP67/LP LF-2PIN IP67 LP Input connector 20 50 5 72668 LF/2CONN/IP67/LP LF-2CONN IP67 LP Board to board connector 7 50 5 *Every Protect module reel comes with one pre-wired input connector and install guide. 0.5 (13.6) 0.4 (9.5) 0.3 (8.4) 0.6 (15.2) 72667 0.2 (5.7) 2 (6) 0.2 (5.7) 1.1 (27) 72363 2 (6) 1.1 (27) 1.2 (30) 20 (506.5) 0.8 (19.8) 18.8 (476.4) 72669 4.7 (120) 0.5 (13.4) 0.7 (18.7) 0.5 (12.7) 72668 7.1 (179.8) Dimensions: inches (mm) Safety Information 1. A ll components of the Connect System must be assembled to avoid any stress on the wires and/or board connectors. The installer must ensure that there is adequate strain relief between the board connection and the wiring. 2. Installation of LED modules (with power supplies) shall be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. 3. T he connector has no inverse polarity protection. There will be no electrical function if connector is not well positioned or if polarity is inversed. Several modules can be damaged. 4. The maximum operation current may not be exceeded. Assembly Information 1. Pay attention to the correct polarity between input connector and LED module: For the input connector, the black cable to the `-' pole and the red cable to the `+' pole of the module. 2. Particular attention is required when using the connector for board to board connection: The `+' pole of the first board has to be connected to the `+' pole of the second board. In case of wrong polarity no light will be emitted and the modules can be damaged. 3. The Termination Cap can be used at any section cut point intended for it. These points are marked on the module. Americas Headquarters 100 Endicott Street Danvers, MA 01923 USA Phone 1-800-LIGHTBULB www.osram-americas.com OSRAM, LINEARlight FLEX and LED CREATING TOMORROW are registered trademarks of OSRAM GmbH. Specifications subject to change without notice. (c) 2015 OSRAM