UHC magnetic float liquid level indicator UQC magnetic ball float liquid level indicator Summary UHC series magnetic float liquid level indicators and UQC series magnetic ball float liquid level indicators are new designed generation liquid level indicator according to magnetic coupling principle. They present the level indication directly and clearly because of the advanced technology and the proper structure and are suitable for liquid level measurement in petroleum, chemical, power, light industry and pharmaceutical industrial field, etc. UHC series magnetic float liquid level indicators are mounted on side of vessels, while UQC series magnetic ball float liquid level indicators are mounted on the top of vessels especially for the measurement for the underground storage tanks. Main technical parameters For local indication Model Contents UHC series magnetic float level indicator UQC series top-mounted magnetic ball-float level indicator Measuring range 06000mm (>6000mm tailor made) 04000mm (>4000mm tailor made) Nominal pressure 1.01.62.54.0MPa 1.01.62.5MPa Nominal diameter DN40 DN150 Ambient temperature -4080 -4080 Operation temperature -40120 (1206000mm tailor made) 04000mm (>4000mm tailor made) Power supply voltage 24V DC 24V DC Output signal 420mA DC 420mA DC Load characteristic See appendix See appendix Ambient temperature -4080 -4080 Operating temperature -40120 -40120 Measuring accuracy 10mm 10mm Associated equipment Guard grating (see appendix) Guard grating (see appendix) Protection class IP65 IP65 Power supply inlet M20x1.5female thread M20x1.5female thread The upper limit and lower limit alarm (they can be fitted at any position within the measuring range) Output signal: one for normal open; one for normal close; Ambient temperature: -4080; Measuring accuracy: 10mm; Service life: 105 times Protection class: IP65; Power supply inlet: M20x1.5 (female thread) Contact capacity: AC200VADC50W Explosion-proof Model UHC magnetic float liquid level indicator UQC magnetic ball float liquid level indicator Upper, lower limits alarm Type Isolating explosion (local) Isolating explosion (remote) Intrinsic Safe (remote) Isolating explosion Intrinsic safe Isolating explosion Explosion mark dBT4 dBT4 iaCT5 dBT4 iaCT5 dBT4 Certificate Of explosion GYB98282 GYB98289 GYB02469 GYB98274 GYB02469 GYB98287 Structure principle UHC series magnetic float liquid level indicators and UQC series magnetic ball float liquid level indicators are composed of body part, local indicator, remote transducer, upper limit and lower limit alarms. UHC series magnetic float liquid level indicators are mounted and connected on the side of vessels. When the float moves up and down with the liquid level (interface level) changing, the magnet steel inside the float drives the magnetic flakes inside of the indicator to roll over according to magnetic coupling principle. All the magnetic flakes are coated with red one side and blue other side. The continuous red or blue zone (red represents the liquid, while blue represents air or gas) can clearly indicate actual liquid level or interface level inside of vessels. While UQC series magnet ball float liquid Dandong Top Electronics Instrument Co., Ltd Add: No..10 Huanghai Street, Zhenxing District, Dandong City, Liaoning Province, P.R. China P.C.: 118000 Tel:+86-415-6227343 Fax: +86-415-6270003 Web site: http://www.ddtop.com E-mail: top@ddtop.com davidsong@ddtop.com level indicators are mounted on the top of vessels. With the liquid or interface level changing, the ball float will move up and down and drive the magnetic connecting rod goes up and down. The magnet steel inside of the connecting rod drives the magnetic flakes inside of the indicator to roll over according to magnetic coupling principle. All the magnetic flakes are coated with red one side and blue other side. The continuous red or blue zone (red represents the liquid, while blue represents air or gas) can clearly indicate actual liquid level or interface level inside of vessels. With remote transducers and upper, lower alarms equipped, the UHC, UQC series indicators can realize to remotely transmit the liquid level signal and perform automatic control. Mode selection sheet Model Specification code Contents UHC- Magnetic float level indicator UHC- Magnetic float liquid level indicator Magnetic ball float liquid level UQC- indicator M With local indicator N Without local indicator S With remote transducer T Without remote transducer A With upper limit alarm B With lower limit alarm C With upper and lower limit alarm D Without alarm E PN1.0MPa F PN1.6MPa G PN2.5MPa J PN4.0MPa ( only for UHC) * level or the interface 1 /2 Measuring range. * For UQC, please note the neck length d Isolating explosion i Intrinsic safe explosion-proof W - With steam jacket Model Selection Example UHC-MSBF0.8/0.5-1800dW is with local indicator, with remote transducer, with lower limit alarm, nominal pressure 1.6MPa, measuring interface, fluids densities 0.8g/m3 and 0.5g/m3 , measuring range 1800mm, isolating explosion, with tracing steam jacket magnetic float liquid level indicator. UQC-MTAG1.05-2000d (neck length: 500mm) is with local indicator, without remote transducer, with upper limit alarm, nominal pressure 2.5MPa, measuring level, fluid density is 1.05 g/m3 , measuring range 2000mm, isolating explosion, neck length 500mm top- mounted magnetic ball float liquid level indicator. UHC magnetic float liquid level indicator outline sketch and installation dimensions Dandong Top Electronics Instrument Co., Ltd Add: No..10 Huanghai Street, Zhenxing District, Dandong City, Liaoning Province, P.R. China P.C.: 118000 Tel:+86-415-6227343 Fax: +86-415-6270003 Web site: http://www.ddtop.com E-mail: top@ddtop.com davidsong@ddtop.com UQC top-mounted magnetic ball float liquid level indicator outline sketch and installation dimensions Note: L (neck length) is the distance between the liquid level and flange surface when the ball float reaches the highest position. Outside Drawings and Installation Dimensions Figure 1 Figure 1 UHC magnetic float local indicating Figure 2 UHC magnetic float local indicaling long distance transmission device Figure 2 Dandong Top Electronics Instrument Co., Ltd Add: No..10 Huanghai Street, Zhenxing District, Dandong City, Liaoning Province, P.R. China P.C.: 118000 Tel:+86-415-6227343 Fax: +86-415-6270003 Web site: http://www.ddtop.com E-mail: top@ddtop.com davidsong@ddtop.com Figure 3 UQC magnetic float local indicaling long distance transmission device alarm Dandong Top Electronics Instrument Co., Ltd Add: No..10 Huanghai Street, Zhenxing District, Dandong City, Liaoning Province, P.R. China P.C.: 118000 Tel:+86-415-6227343 Fax: +86-415-6270003 Web site: http://www.ddtop.com E-mail: top@ddtop.com davidsong@ddtop.com Figure 1 Figure 1 UQC magnetic ball-float local indicaling Figure 2 UQC magnetic ball-float local indicaling long distance transmission device Figure 2 Dandong Top Electronics Instrument Co., Ltd Add: No..10 Huanghai Street, Zhenxing District, Dandong City, Liaoning Province, P.R. China P.C.: 118000 Tel:+86-415-6227343 Fax: +86-415-6270003 Web site: http://www.ddtop.com E-mail: top@ddtop.com davidsong@ddtop.com Figure 3 UQC magnetic ball-float local indicaling long distance transmission device alarm Note: L(neck length) is the distance between the liquid level and flange surface when the ball float reaches the highest position. Dandong Top Electronics Instrument Co., Ltd Add: No..10 Huanghai Street, Zhenxing District, Dandong City, Liaoning Province, P.R. China P.C.: 118000 Tel:+86-415-6227343 Fax: +86-415-6270003 Web site: http://www.ddtop.com E-mail: top@ddtop.com davidsong@ddtop.com