https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 24VDC/3A C2LPS Product Description TRIO POWER power supplies with standard functionality The TRIOPOWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads. Your advantages Save time and costs, thanks to the Push-in connection and narrow design Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds Maximum flexibility due to the wide temperature range from -25C to +70C and device startup at -40C Rugged design Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356959445 Weight per Piece (excluding packing) 460.000 g Custom tariff number 85044030 Country of origin China Technical data Dimensions Width 30 mm Height 130 mm 08/25/2020Page1/9 https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Technical data Dimensions Depth 115 mm Installation distance right/left 0 mm / 0 mm Installation distance top/bottom 50 mm / 50 mm Ambient conditions Degree of protection IP20 Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Ambient temperature (operation) -25 C ... 70 C (> 60 C Derating: 2.5 %/K) Ambient temperature (start-up type tested) -25 C Ambient temperature (storage/transport) -40 C ... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Installation height 5000 m (> 2000 m, observe derating) Input data Nominal input voltage range 100 VAC ... 240 VAC 110 VDC ... 250 VDC Input voltage range 100 VAC ... 240 VAC -15% ... +10% 99 VDC ... 275 VDC Dielectric strength maximum 300 VAC 15 s AC frequency range 50 Hz ... 60 Hz 10% Discharge current to PE < 0.25 mA Current consumption 1.4 A (100VAC) 1 A (120 V AC) 0.6 A (230 V AC) 0.7 A (240 V AC) Nominal power consumption 157.7 VA Inrush current 15 A (typical) Mains buffering time typ. 10 ms (120 V AC) typ. 20 ms (230 V AC) Input fuse 6.3 A (internal (device protection)) Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K) Power factor (cos phi) 0.52 Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 VDC 1% 08/25/2020Page2/9 https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Technical data Output data Setting range of the output voltage (USet) 24 VDC ... 28 VDC (> 24 VDC, constant capacity restricted) Nominal output current (IN) 3A Dynamic Boost (IDyn.Boost) 4.5 A (1 s) Derating > 60 C ... 70 C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Feedback voltage resistance 35 VDC Protection against overvoltage at the output (OVP) 30 VDC Control deviation < 1 % (change in load, static 10 % ... 90 %) < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) < 0.1 % (change in input voltage 10 %) Residual ripple < 50 mVPP (with nominal values) Output power 72 W Typical response time <1s Maximum power dissipation in no-load condition <1W Power loss nominal load max. < 10 W General Net weight 0.35 kg Efficiency > 89 % (for 230 V AC and nominal values) MTBF (IEC 61709, SN 29500) > 3500000 h (25C) > 2000000 h (40C) > 930000 h (60C) Insulation voltage input/output 3 kV AC (type test) 1.5 kV AC (routine test) Degree of protection IP20 Protection class II (in closed control cabinet) Inflammability class in acc. with UL 94 (housing / terminal blocks) V0 Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: horizontally 0 mm ( 40 C) 10 mm ( 70 C), vertically 50 mm Connection data, input Connection method Push-in connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 4 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 08/25/2020Page3/9 https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Technical data Connection data, input Conductor cross section AWG max. 12 Stripping length 10 mm Connection data, output Connection method Push-in connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 4 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 8 mm Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 1.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 1.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Standards EMC requirements for noise immunity EN61000-6-1 EN61000-6-2 EMC requirements for noise emission EN61000-6-3 EN61000-6-4 Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only) Standard - Electrical safety IEC60950-1/VDE0805 (SELV) Standard - Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN50178/VDE0160 (PELV) Standard - Safety extra-low voltage IEC60950-1 (SELV) and EN60204-1 (PELV) Standard - Safe isolation DINVDE0100-410 Standard - Limitation of mains harmonic currents EN61000-3-2 Rail applications EN50121-4 Conformance/approvals UL approvals UL Listed UL508 UL/C-UL Recognized UL 60950-1 08/25/2020Page4/9 https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Technical data Conformance/approvals NEC Class 2 as per UL 1310 EMC data Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Electrostatic discharge EN 61000-4-2 Contact discharge 6 kV (Test Level 4) Discharge in air 8 kV (Test Level 4) Electromagnetic HF field EN61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m (Test Level 3) Frequency range 1 GHz ... 2 GHz Test field strength 10 V/m (Test Level 3) Frequency range 2 GHz ... 3 GHz Test field strength 10 V/m (Test Level 3) Comments Criterion A Fast transients (burst) EN61000-4-4 Input 4 kV (Test Level 4 - asymmetrical) Output 2 kV (Test Level 3 - asymmetrical) Signal 1 kV (Test Level 2 - asymmetrical) Comments Criterion A Surge voltage load (surge) EN61000-4-5 Input 3 kV (Test Level 3 - symmetrical) 6 kV (Test Level 4 - asymmetrical) Output 1 kV (Test Level 2 - symmetrical) 2 kV (Test Level 1 - asymmetrical) Signal 1 kV (Test Level 2 - asymmetrical) Comments Criterion B Conducted interference EN61000-4-6 Frequency range 0.15 MHz ... 80 MHz Voltage 10 V (Test Level 3) Comments Criterion A Criterion A Normal operating behavior within the specified limits. Criterion B Temporary impairment to operational behavior that is corrected by the device itself. Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; 08/25/2020Page5/9 https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Technical data Environmental Product Compliance For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram Classifications eCl@ss eCl@ss 10.0.1 27040701 eCl@ss 4.0 27040700 eCl@ss 4.1 27040700 eCl@ss 5.0 27049000 eCl@ss 5.1 27049000 eCl@ss 6.0 27049000 eCl@ss 7.0 27049002 eCl@ss 8.0 27049002 eCl@ss 9.0 27040701 ETIM ETIM 4.0 EC002540 ETIM 5.0 EC002540 ETIM 6.0 EC002540 ETIM 7.0 EC002540 08/25/2020Page6/9 https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Classifications UNSPSC UNSPSC 13.2 39121004 UNSPSC 18.0 39121004 UNSPSC 19.0 39121004 UNSPSC 20.0 39121004 UNSPSC 21.0 39121004 Approvals Approvals Approvals DNV GL / UL Listed / UL Recognized / cUL Recognized / IECEE CB Scheme / cUL Listed / EAC / cULus Recognized / cULus Listed Ex Approvals UL Listed / cUL Listed / cULus Listed Approval details DNV GL https://approvalfinder.dnvgl.com/ TAA00000BM UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 IECEE CB Scheme http://www.iecee.org/ DK-44782-A1-M1-UL 08/25/2020Page7/9 https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Approvals cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 EAC RU*DE*08.B.01873/19 cULus Recognized cULus Listed Accessories Accessories Device circuit breakers Electronic device circuit breaker-CBM E4 24DC/0.5-10A NO-R-2905743 Multi-channel, electronic device circuit breaker with active current limitation for protecting four loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails. Electronic device circuit breaker-CBM E8 24DC/0.5-10A NO-R-2905744 Multi-channel, electronic device circuit breaker with active current limitation for protecting eight loads at 24 V DC in the event of overload and short circuit. With nominal current assistant and electronic locking of the set nominal currents. For installation on DIN rails. Device protection 08/25/2020Page8/9 https://www.phoenixcontact.com/us/products/2903147 Power supply unit-TRIO-PS-2G/1AC/24DC/3/C2LPS-2903147 Accessories Type 3 surge protection device-PLT-SEC-T3-230-FM-PT-2907928 Type 2/3 surge protection, consisting of protective plug and base element with Push-in connection. For single-phase power supply network with integrated status indicator and remote signaling. Nominal voltage 230VAC/DC. Type 3 surge protection device-PLT-SEC-T3-24-FM-PT-2907925 Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage 24VAC/DC. Potential distributor Potential distributors-VIP-2/SC/PDM-2/24-2315269 VARIOFACE module, with two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 70.4 mm Potential distributors-VIP-3/PT/PDM-2/24-2903798 VARIOFACE module with push-in connection and two equipotential busbars (P1, P2) for potential distribution, for mounting on NS 35 rails. Module width: 57.1 mm Phoenix Contact 2020 (c) - all rights reserved http://www.phoenixcontact.com 08/25/2020Page9/9