3
www.power-one.com
Control
Output voltage adjustment output 1, 4 60/80...110%
U
o nom
Inhibit on input side TTL input, output(s) disabled if open circuit
Status indication LEDs: In OK, Out OK
Output good signal (Out OK) isolated open collector signal
Safety
Approvals pending EN 60950, UL 1950, CSA C22.2 No. 950
Class of equipment class I
Protection degree IP 40
Electric strength test voltage I/case, O/case, Out OK/case 1.5 kV AC
I/O, Out OK/I, Out OK/O 3 kV AC
O/O 500 V DC
EMC
Electrostatic discharge IEC/EN 61000-4-2, level 4 (8/15 kV) criterion B
Electromagnetic field IEC/EN 61000-4-3, level 3 (10 V/m) criterion A
Electr. fast transients/bursts IEC/EN 61000-4-4, output/input, level 3/4 (2/4 kV) criterion B
Surge IEC/EN 61000-4-5, input, level 2/3 (1/2 kV) criterion B
Conducted disturbances IEC/EN 61000-4-6, level 2/3 (3/10 V) criterion A
Electromagnetic emissions CISPR 22/EN 55022, conducted class B
Environmental
Operating ambient temperature
U
i nom,
P
o nom, convection cooled –25...71°C
Operating case temperature
T
C
U
i nom,
P
o nom/
P
o max –25...95°C
Storage temperature non operational –40...100°C
Damp heat IEC/EN 60068-2-3, 93%, 40°C 56 days
Vibration, sinusoidal IEC/EN 60068-2-6, 10...60/60...2000 Hz 0.35 mm/5 gn
Shock IEC/EN 60068-2-27, 11 ms 50 gn
Bump IEC/EN 60068-2-29, 11 ms 25 gn
Random vibration IEC/EN 60068-2-64, 20...500 Hz 4.9 gn rms
Options
Extended temperature range –40...71°C, ambient, operating -9
Out OK output excludes option i D
VME compatible monitoring circuit, excludes option i and D V
Current sharing T
Inhibit on output side excludes option D i
Synchronisation W
Kühlkörper B1