CII TD2 Series Commercial or Military Time Delay Relay
With Fixed or Adjustable Delay On Operate or Release
1
Product Facts
IPending qualification to:
MIL-PRF-83726/28,
MIL-PRF-83726/29,
MIL-PRF-83726/30 &
MIL-PRF-83726/31.
IFixed delay on operate,
fixed delay on release,
adjustable delay on operate
& adjustable delay on
release.
IMeets or exceeds
electrostatic discharge
MIL-STD-1686 Class
Non-Sensitive.
IWelded hermetically sealed
enclosure occupies about 1
in3(16.4 cm3).
I10A, 2 form C (DPDT)
output contacts.
Catalog 9-1773447-6 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 03-2008 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-1106-0803 UK: 44-208-420-8341
TD2 series time delay relays
are available for delay on
operate or delay on release
operation. Either can be
supplied as fixed or resistor
adjustable types. Both military
and commercial versions are
offered.
These products consist of solid
state timing circuits controlling
our FCA-210 series relays,
providing 2 Form C (DPDT)
output contacts rated 10 amps.
The internal timing circuit uses
an R/C controlled oscillator with
a programmable digital pulse
counter, gating a semiconductor
switch to operate the relay.
Timing is independent of
whether the controlling voltage
is a ramp or step function.
For the adjustable models the
user specifies a one decade
range in seconds, within which
the required delay will be set.
This range is programmed
internally at the time of
manufacture. The required
delay is obtained by calculating
the oscillator timing resistor as
follows and connecting it
externallly to terminals 1D - 3D
as below.
REXT = [(T1/ T0) -1] 100K
Ohms
T0= Minimum time of selected
decade in seconds.
T1 = Required time delay.
EXAMPLE
Selected Range = 3-30 sec
Required Time = 15 sec
REXT = [(15/3) -1] 100K = 400K
© 2007, 2008 by Tyco Electronics Corporation. All Rights Reserved.
CII, TE logo and Tyco Electronics are trademarks.
Other products and company names mentioned herein may be trademarks of their respective owners.
Timing Action and Terminal Wiring
BLUE BEAD
+X1
-X2123
TD
D
C
B
A
INPUT
(–)
(+)
Delay On Operate:
The time delay starts on the application of input voltage to X1-X2. The timing
circuit energizes the relay at the end of the time delay period.
Delay On Release:
The input voltage is continuous to X1-X2. When the control voltage is applied to
C1-X2 the timing circuit and the relay are both energized. The time delay relay
starts when the control voltage is shut off.
BLUE BEAD
+X1
-X2 1 2 3
TD
D
C
B
A
INPUT
(–)
(+)
CONTROL
(+)
BLUE BEAD
+X1
-X2123
TD
D
C
B
A
INPUT
(–)
(+)
EXT. RESISTOR 1/4 WATT MIN.
BLUE BEAD
+X1
-X2 1 2 3
TD
D
C
B
A
INPUT
(–)
(+)
CONTROL
(+)
EXT. RESISTOR 1/4 WATT MIN.
Fixed Model Fixed Model
Adjustable Model Adjustable Model
Terminal designations shown in the diagrams above are for reference only. They do not appear on the relay header.
INPUT OFF
INPUT VOLTAGE
+X1 / –X2
OUTPUT
RELAY
20-30VDC
DEENERGIZED
ENERGIZED
TIME
DELAY
CONTROL OFF
CONTROL VOLTAGE
+C1 / –X2
OUTPUT
RELAY
20-30VDC
DEENERGIZED
ENERGIZED
INPUT OFF
INPUT VOLTAGE
+X1 / –X2
20-30VDC
TIME DELAY
2
CII High Performance Electronic Products
Specifications
Timing Data
Timing Action Delay on Operate or Delay on Release
Time Delay, Fixed – M83726/28, /29 and Commercial 28C, 29C Select from 0.1 to 600 sec for Commercial Models
Select from 0.1 to 500 sec for Mil-Spec Models
Time Delay, Adjustable – M83726/30, /31 and Commercial 30C, 31C Select one decade between 0.1 to 1.0 and 60 to 600 seconds
Timing Accuracy (note 1) ±10% of Nominal Value
Recycle Time (note 2) 50 ms, max., to next cycle.
Power Interrupts Accuracy is not affected by power interruptions up to 1 ms spaced at least 10ms apart.
Input Data
Input Voltage 28 Vdc nominal, range 20 - 32 Vdc
Duty Rating Continuous
Input Current 110 mAdc Max @ 25°C
Control Voltage (applies only to Delay on Release type) 20 - 32 Vdc
Control Current 15 mAdc Max (applies only to delay on release types)
Input Voltage Polarity Protection The timer will be inoperative during, and undamaged by, reversal of the polarity of the input voltage.
Output Data
Contact Form 2 Form C (DPDT)
Contact Material Silver Cadimum Oxide, Gold plated
Contact Rating in Amps (Continuous Duty)
Type of Life (Min.) 115 Vac 115/200 Vac – 3 phase
Load Cycles 28 Vdc 400Hz 400 Hz. 60 Hz.*
Resistive 100 x 10310 10 10 2.5
Inductive 20 x 1038882.5
Motor 100 x 1034442.0
Lamp 100 x 1032221.0
* 60 Hz. loads are rated at 10 x 103cycles.
Overload Current 40 Adc; 60A, 400 Hz.
Rupture Current 50 Adc; 80A, 400 Hz.
Max. Contact Drop at 10A Initial 0.150V; After Life 0.175V
Electrical Data
Electrostatic Discharge Withstand Voltage 16,000V
Transients (note 3):
Positive Transients +80V
Self-generated Transients ±50V, Max.
Spike Susceptability ±600V, 10 µs, Max.
Insulation Resistance (note 4) 1,000 megohms at 500Vdc, between each pin and case
Dielectric Strength (note 4) 1,000Vrms at 60 Hz at sea level, between case and all pins connected together
Environmental Data
Ambient Temperature Range, Operating -55°C to +125°C
Altitude 300,000 feet
Shock Resistance 100 G’s, 6 ms.
Vibration Resistance, Sinusoidal Z & Y Enclosure: 30 G’s, 33-3000Hz.; X & W Enclosure: 20 G’s, 33-3000Hz.
Mechanical Data
Approximate Weight 2.5 oz. (71g) Max.
NOTES
1. The accuracy requirement applies to any combination of operating temperature and voltage. Add ±10ms for timing less than one second.
2. Recycle time to assure that the next timing cycle will be completed. Units can be recycled during timing and after time-out:
Delay on operate models – Power must be OFF the input at least 10 ms. Delay on release models – Power must be ON the control terminal at least 10 ms.
3. Transient specifications are based on a maximum duty cycle of 1/50.
4. All wired terminals must be connected together during this test. Dielectric withstanding voltage and insulation resistance are measured between all mutually
insulated wired terminals and between all these terminals and case.
TD2 Series Time Delay Relay (Continued)
Catalog 9-1773447-6 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 03-2008 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-1106-0803 UK: 44-208-420-8341
Outline Dimensions
The standard terminal types and enclosures are illustrated below with dimensions expressed as inches ± 0.010 and (millimeters ±0.25).
All terminals on 0.200 (5.4) centers.
BLUE BEAD
.050 ± .005
(1.27 ± (3)
Silicone
Rubber
Gasket
+X 1
-X2
.270
(6.86)
CODE "T"
-X2
.270
(6.86)
Circuit Board Pins – Tin/Lead Plated
BLUE BEAD
.300 ± .020
(7.26) ± .51
0.80 DIA
(2.03)
-X2
+X 1
.062 Dia. Pin
(1.57 ) 14 Plcs.
+ .002
- .001
+ .05
- .02
Solder Hooks
CODE "S"
.062 ±.001 Pin
(1.57 ± .02)
14 places
.062 Dia. Pin
(1.57 ) 14 Plcs.
+ .002
- .001
+ .05
- .02
CODE "P"
Socket Pins – Gold Plated
BLUE BEAD
TD2 Series Time Delay Relay (Continued)
All Enclosures have cupro-nickel cans bright acid tin/lead plated after assembly to terminal headers.
CODE
"Z" 1.015
(25.79)
1.015
(25.79)
1.015
(25.79)
1.396
(35.46)
1.446
(36.73)
1.718 Max.
(43.64)
1.00
(25.4)
1.015
(25.79)
.150 typ.
(3.8)
.040
(1.02)
.156
(3.96)
1.015
(25.79)
FULL R
6 PLCS
.625
(15.88)
.937
(23.80)
.312
(7.92)
CODE
"Y"
CODE
"W" 6-32 UNC-2A
3 Studs *
.047
(1.20)
.312
(7.92)
1.051
(25.79)
1.015
(25.78)
.687
(17.44)
1.00
(25.4)
.375
(9.52)
.343
(8.71)
.160
(4.06)
.160
(4.06)
1.396
(35.46) 1.446
(36.73)
1.015
(25.79)
FULL R
6 PLCS
1.00
(25.4)
.625
(15.88)
1.718 Max.
(43.64)
.040
(1.02)
1.051
(25.79)
.150 typ.
(3.8)
CODE
"X"
*Metric threads available. To specify use “M” in place of “W”
.937
(23.80)
.687
(17.44)
3
CII High Performance Electronic Products
Terminals
Enclosures
Catalog 9-1773447-6 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 03-2008 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-1106-0803 UK: 44-208-420-8341
4
CII High Performance Electronic Products
TD2 Series Time Delay Relay (Continued)
Typical Mil-Spec Part Number TD2 28- 5002 P
Series:
TD2 = Time delay relay with 2 pole, 10A output
Mil-Spec Model:
28 = M83726/28 (Fixed, Delay on Operate)
29 = M83726/29 (Fixed, Delay on Release)
30 = M83726/30 (Adjustable, Delay on Operate)
31 = M83726/31 (Adjustable, Delay on Release)
Time Delay Range (Within 0.1 to 500 seconds):
For /28 and /29 types (fixed types), the delay is expressed in
milliseconds in a four-digit code. The first three digits are significant.
The fourth is the number of zeros following the first three.
Example: 5002 is 50 seconds.
For /30 and /31 types (adjustable types), the delay decade range is
expressed in milliseconds in a four-digit code represesnting the upper
limit of the range. The first three digits are significant. The fourth is the
number of zeros following the first three.
Example: 1001 is 1 second, so the range is 0.1 to 1 second.
Terminals:
P= Socket Pin Terminals
S= Solder Hook Terminals
Note: Mil-spec models have “Y” type enclosure.
Part Numbering System
Mil-Spec Types (Qualification Pending) Commercial Types
Typical Commercial Part Number TD2 28C- 1001 P Y
Series:
TD2 = Time delay relay with 2 pole, 10A output
Commercial Model:
28C = Fixed, Delay on Operate (COTS version of M83726/28)
29C = Fixed, Delay on Release (COTS version of M83726/29)
30C = Adjustable, Delay on Operate (COTS version of M83726/30)
31C = Adjustable, Delay on Release (COTS version of M83726/31)
Time Delay Range (Within 0.1 to 600 seconds):
For fixed types, the delay is expressed in milliseconds in a four-
digit code. The first three digits are significant. The fourth is the
number of zeros following the first three.
Example: 5002 is 50 seconds.
For adjustable types, the delay decade range is expressed in
milliseconds in a four-digit code represesnting the upper limit of
the range. The first three digits are significant. The fourth is the
number of zeros following the first three.
Example: 1001 is 1 second, so the range is 0.1 to 1 second.
Terminals:
P= Socket Pin Terminals
S= Solder Hook Terminals
T= Solder Pin Terminals
Enclosure
W = Mounting Studs
X = Horizontal Flange Mount
Y = Raised Vertical Flange Mount
Z = No Mount
9-1773447-6–PDF–TW–3-08
Catalog 9-1773447-6 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 03-2008 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-1106-0803 UK: 44-208-420-8341