26/02/2014 www.crouzet.com 22.5 mm DIN rail mounting TK2R1 Part number 88865265 Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator Option of connecting an external power supply to the control input 3-wire sensor control option Part numbers 88 865 265 Type Functions Timing Output Nominal rating Connections Supply voltage TK2R1 K 0,6s160 s 2 change over relays 8A Screw terminals 24 V DC / 24 240 V AC Specifications Timing Timing ranges (7 ranges) Repetition accuracy with constant parameters Drift Temperature Drift Voltage Display accuracy according to IEC/EN 61812-1 Minimum pulse duration typically (relay version) Minimum pulse duration typically (solid state version) Minimum pulse duration typically (relay version under load) Maximum reset time by de-energisation typically (relay version) Maximum reset time by de-energisation typically (solid state version) Immunity from micro power cuts : typical Supply Multi-voltage power supply Frequency (Hz) Operating range Operating factor Max. absorbed power 1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h TK2R1 : 0.6s - 2.5s - 20s - 160 s 0.5 % (IEC/EN 1812-1) 0,05 % / C 0.2 % / V 10 % / 25 C 30 ms 50 ms 100 ms 100 ms 350 ms > 10 ms *** TRADUCTION MANQUANTE *** Depending on version 50 / 60 85 to 110 % Un (85 to 120 % Un for 12V AC/DC) 100 % 0,6 W 24 V AC/DC 1,5 W 230 V AC 32 VA 230 V AC Output specification 1 or 2 changeover relays, AgNi (cadmium-free) Rated power Maximum breaking current Minimum breaking current Voltage breaking capacity Electrical life (operations) 2000 VA/80 W 2000 VA/80 W 8 A AC 8A DC 10 mA / 5 V DC 250 V AC/ DC Mechanical life (operations) 5x106 2.5 kV /1 min / 1 mA / 50 Hz 5 kV, wave 1.2 / 50 s Breakdown voltage acc. to IEC/EN 61812-1 Impulse voltage acc. to IEC/EN 60664-1, IEC/EN 61812-1 10 5 operations 8 A 250 V resistive Solid state output Rated power Derating Maximum admissible current Minimum breaking current Leakage current Voltage breaking capacity Maximum voltage drop at terminals Electrical life (operations) Mechanical life (operations) Breakdown voltage acc. to IEC/EN 60664-1, IEC/EN 60255-5 Input type 0,7 A AC/DC 20 C (0,5 A UL) 5 mA / C 20 A 10 ms 10 mA < 5 mA 250 V AC/ DC 3 wire 4V - 2 wire 8V 108 108 2.5 kV to 1 mA / 1 min Volt-free contact 3-wire PNP output control option residual voltage : 0.4V whatever the timer power supply Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 26/02/2014 www.crouzet.com General characteristics Conformity to standards IEC/EN 61812-1 IEC/EN 61000-6-1 IEC/EN 61000-6-2 IEC/EN 61000-6-3 IEC/EN 61000-6-4 CE, UL, cUL, CSA, GL -20 +60 -30 +60 Certifications Temperature limits use (C) Temperature limits stored (C) Installation category Voltage surge category (acc. to IEC/EN 60664-1) Creepage distance and clearance acc. to IEC/EN 60664-1 4 kV / 3 Protection (IEC/EN 60529) IP 20 IP 40 Degree of protection acc. to IEC/EN 60529 Front face IP 50 (except Tk2R1) Vibration resistance f = 10 55 Hz acc. to IEC/EN 60068-2-6 A = 0,35 mm Relative humidity no condensation acc. to IEC/EN 6006893 % sans condensation 2-30 Electromagnetic compatibility - Immunity to electrostatic Level III (Air 8 KV / Contact 6 KV) discharges acc to IEC/EN 61000-4-2 Immunity to radiated, radio-frequency, electromagnetic Level III 10V/m (80 M Hz to 1 G Hz) field acc. IEC/EN 61000-4-3 Immunity to rapid transient bursts acc. to IEC/EN 61000-4Level III (direct 2kV / Capacitive coupling clamp 1 KV) 4 Immunity to shock waves on power supply acc. to IEC/EN Level III (2 KV / common mode 2 KV/residual current mode 1KV) 61000-4-5 Immunity to radio frequency in common mode acc. to Level III (10V rms : 0.15 M Hz to 80 M Hz) IEC/EN 61000-4-6 Immunity to voltage dips and breaks acc. to IEC/EN 61000- 30 %/10 ms 4-11 60 %/100 ms > 95 %/5 s Mains-borne and radiated emissions acc. to EN 55022 Class B (CISPR22), EN55011 (CISPR11) Fixing : Symmetrical DIN rail 35 mm Connection capacity - without ferrule 2 x 2,5 mm2 Connection capacity - with ferrule 2 x 1,5 mm2 Spring terminals, 2 terminals per connection point flexible wire Spring terminals, 2 terminals per connection point - rigid wire Housing material Weight : casing 17,5 mm Weight : casing 22,5 mm Weight : plug-in casing 1,5 mm2 2,5 mm2 Self-extinguishing 60 g 90 g 80 g 90 Display State displayed by 2 LEDs - Flashing green when on - Relay LED yellow during timing Green LED operation indicator Pulsing : - Timer on, no timing in process Permanently lit : - Relay waiting, no timing in process Dimensions (mm) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 26/02/2014 Curves Function K- 2 relay outputs Function K Delay on de-energisation True delay OFF 2 relays Connections 2 changeover relay outputs Function K Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 88865265