IRAM136-1061A
Static Electrical Characteristics Driver Function
Symbol Definition Min Typ Max Units
VIN,th+ Positive going input threshold for LIN, HIN, FLT/EN 2.5 --- --- V
VIN,th- Negative going input threshold for LIN, HIN, FLT/EN --- --- 0.8 V
VCCUV+, VBSUV+ VCC/VBS supply undervoltage, Positive going threshold 10.6 11.1 11.6 V
VCCUV-, VBSUV- VCC/VBS supply undervoltage, Negative going threshold 10.4 10.9 11.4 V
VCCUVH, VBSUVH VCC and VBS supply undervoltage lock-out hysteresis --- 0.2 --- V
IQBS Quiescent VBS supply current --- --- 120 μA
IQCC Quiescent VCC supply current --- --- 2.3 mA
ILK Offset Supply Leakage Current --- --- 50 μA
IIN+ Input bias current VIN=3.3V for LIN, HIN, FLT/EN --- 100 195 μA
IIN- Input bias current VIN=0V for LIN, HIN, FLT/EN -1 -- --- μA
ITRIP+ ITRIP bias current VT/ITRIP=3.3V --- 3.3 6 μA
ITRIP- ITRIP bias current VT/ITRIP=0V -1 --- --- μA
V(ITRIP)I
TRIP threshold Voltage 0.44 0.49 0.54 V
V(ITrip, HYS) ITRIP Input Hysteresis --- 0.07 --- V
Ron_FLT Fault low on resistance --- 50 100
VBIAS (VCC, VBS1,2,3)=15V, TJ=25ºC, unless otherwise specified. The VIN and IIN parameters are referenced to COM and
are applicable to all six channels. (Note 3)
Dynamic Electrical Characteristics
Symbol Parameter Min Typ Max Units Conditions
T
ON
Input to Output propagation turn-
on delay time (see fig.11) --- --- 1.15 μs
T
OFF
Input to Output propagation turn-
off delay time (see fig. 11) --- --- 1.15 μs
T
FILIN
Input filter time (HIN,LIN) --- 310 --- ns V
IN
=0 or V
IN
=5V
T
FILEN
Input filter time (FLT/EN) 100 200 --- ns V
IN
=0 or V
IN
=5V
T
EN
EN low to six switch turn-off
propagation delay (see fig. 3) --- --- 1.35 μs V
IN
=0 or V
IN
=5V, V
EN
=0
T
FLT
I
TRIP
to Fault propagation delay 400 600 800 ns V
IN
=0 or V
IN
=5V, V
ITRIP
=5V
T
BLT-ITRIP
I
TRIP
Blanking Time 100 150 --- ns V
IN
=0 or V
IN
=5V, V
ITRIP
=5V
T
ITRIP
I
TRIP
to six switch turn-off
propagation delay (see fig. 2) --- --- 1.5 μs I
C
=5A, V
+
=300V
D
T
Internal Dead Time injected by
driver 220 290 360 ns V
IN
=0 or V
IN
=5V
M
T
Matching Propagation Delay Time
(On & Off) all channels --- 40 75 ns External dead time> 400ns
1.17 1.7 2.19 T
C
= 25°C
1 1.5 1.9 T
C
= 100°C
I
C
=5A, V
+
=300V
V
BIAS
(V
CC
, V
BS1,2,3
)=15V, T
J
=25ºC, unless otherwise specified. Driver only timing unless otherwise specified.
T
FLT-CLR
Post I
TRIP
to six switch turn-off
clear time (see fig. 2) ms
www.irf.com 5