CB9100 Series Supplemental Circuit Breakers
Circuit Breakers
Thermal Magnetic Type
Rated from 0.5 to 63 amps
Available in single, double and triple
pole configurations
Optional auxiliary contacts
Mounts on 35mm DIN-rail
UL and CSA approvals
CSA 277 VAC (1 pole) or
480 VAC (2 and 3 pole)
50 VDC (0.5 A to 50 A) 1 pole
110 VDC (0.5 A to 50 A) 2 pole
CB9100 Series
Single Pole
CB9100 Series
Double Pole
CB9100 Series
Triple Pole
Ordering Data Type: Single Pole Type: Double Pole Type: Triple Pole
Current Ratings Current Ratings Current Ratings
(amps) Part No. (amps) Part No. (amps) Part No.
0.5 9925350000 0.5 9925650000 0.5 9925810000
1.0 9925360000 1.0 9925660000 1.0 9925820000
2.0 9925380000 2.0 9925680000 2.0 9925840000
3.0 9925390000 3.0 9925690000 3.0 9925850000
4.0 9925400000 4.0 9925700000 4.0 9925860000
6.0 9925410000 6.0 9925710000 6.0 9925870000
10.0 9925430000 10.0 9925730000 10.0 9925890000
13.0 9929820000 13.0 9929830000 13.0 9929840000
16 9925440000 16 9925740000 16 9925900000
20 9925450000 20 9925750000 20 9925910000
25 9925460000 25 9925760000 25 9925920000
32 9925470000 32 9925770000 32 9925930000
40 9925480000 40 9925780000 40 9925940000
50 9925490000 50 9925790000 50 9925950000
63 9925500000 63 9925800000 63 9925960000
Trip Curves
Thermal Magnetic Type
Typical time/current characteristics at 23°C
0.8 1 2 3 4 6 8 10 20 30 50 70 100
0.001
0.01
0.1
1
10
100
1,000
10,000
… times rated current
Trip time in seconds
23°C
M1 0.5 to 6 A
0.8 1 2 3 4 6 8 10 20 30 50 70 100
0.001
0.01
0.1
1
10
100
1,000
10,000
… times rated current
Trip time in seconds
23°C
M1 AC 10 to 40 A
0.8 1 2 3 4 6 8 10 20 30 50 70 100
0.001
0.01
0.1
1
10
100
1,000
10,000
… times rated current
Trip time in seconds
23°C
M1 AC 63 A
Note: “C” trip time characteristics according to VDE 064 A4/11.88 (9100 Series only)
CB9100 Series
15
CB9100 Series Supplemental Circuit Breakers
Technical Data
Rated voltage & current
UL 1077
CSA C 22.2 No. 235
VDE
Creepage resistance
Insulation resistance
Interrupting capacity
(UL 1077/EN 609334 PC1) 1 pole
Mechanical/Electrical endurance
Shock
Torqu e
Vibration
Temperature range - operating
Weight
Strip length
Auxiliary contact rating
Wire size - #22…12 AWG
Wire size
Accessories
Jumpers
Auxiliary contacts
SPDT
Security hardware
Marking Tags
Adhesive label
277 V (1 pole) 480 V (2 and 3 pole) 50 VDC (1 pole) 110 VDC (2 pole)
277 V (1 pole) 480 V (2 and 3 pole) 50 VDC (1 pole) 110 VDC (2 pole)
PTI 250 to IEC 112
>100 MMat 500 VDC
Current ratings Interrupting Rupture capacity (3X) Voltage
0.5...63 A 10,000 A (UL) 277 VAC/50 VDC
0.5...32 A 2,000 A (UL) 347 / 600 AC
0.5...63 A 6,000 A (UL) 50 VDC (1) pole
0.5...50 A 6,000 A (UL) 110 VDC (2) poles
20,000/10,000
20 g (10 ms)
2 Nm
3 g (10 to 55 Hz)
-25°C...+55°C (-13°F to 131°F)
1 pole (130 g); 2 pole (280 g); 3 pole (430 g)
12 mm
Voltage Current
AC 220/240 5 A
AC 277 3 A
DC 24 V 4 A
DC 60 V 1 A
DC220 V 0.4 A
#18…2 AWG (line); #18…3 AWG (load)
Type Part No.
3 pole bus, 10 x 1010 mm, buses (19) 3 phase groupings 9970330000
3 pole bus, 16 x 210 mm, buses (4) 3 phase groupings 9970340000
3 pole bus, 16 x 1010 mm, buses (19) 3 phase groupings 9970350000
1 pole bus, 12 x 210 mm, buses 12 breakers 9970360000
1 pole bus, 12 x 210 mm (insulated), buses 12 breakers 9991990000
Bus bar clamp 9970370000
Auxiliary contacts 9970300000
Lock out cover 9970380000
ETO 10/26, yellow (26 mm x 10 mm) 1686401687