30 to 40 Watt AC/DC - Converter Open Frame o Universal Input 90-264 VAC o 2 x 4 Inch - Footprint o Industry-Standard Pin Out o Meets UL/cUL, TUV, CE o Conductive EMI meets CISPR/FCC Class B airflow o Short Circuit / Over Load / Over Voltage Protection E197581 OUTPUT CURRENT MODEL NUMBER OUTPUT VOLTAGE MIN. ACS40-3.3 RATED RIPPLE* (mV p-p) OUTPUT POWER MAX. (W) % EFF 50 19.8 74 30 78 MAX 3.3 VDC 6.0 A ACS40-5 5 VDC ACS40-9 9 VDC 4.45 A 40.1 82 ACS40-12 12 VDC 3.34 A 40.1 84 ACS40-15 15 VDC 40.1 85 0A - 2.67 A 1% ACS40-24 24 VDC 1.67 A 40.1 86 ACS40-30 30 VDC 1.33 A 39.9 86 ACS40-36 36 VDC 1.11 A 40.0 87 ACS40-48 48 VDC 0.834 A 40.0 88 40.0 77 40.0 78 5 VDC 0.4 A 3.2 A 5.0 A 50 12 VDC 0.2 A 2.0 A 2.5 A 120 5 VDC 0.4 A 3.2 A 5.0 A 50 24 VDC 0.2 A 1.0 A 1.5 A 240 ACD40-5/12 ACD40-5/24 last up-date 25.11.2004 30-40 Watt - AC/DC-Converter - Open Frame - ACS/D/T-Serie 2/7 S P E C I F I C AT I O N S All Specifications Typical At Nominal Line, 75% Load, and 25C Unless Otherwise Noted OUTPUT CURRENT MODEL NUMBER ACT40-12/5 ACT40-5/12 ACT40-15/5 ACT40-5/-12/24 ACT40-24/5 ACT40-5/12/24 ACT40-3.3/5/12 RIPPLE (mV p-p) OUTPUT VOLTAGE MIN. RATED MAX +5 V1DC 0.4 A 3.0 A 5.0 A 50 +12 V2DC 0.2 A 2.0 A 2.5 A 120 -5 V3DC 0A 0.3 A 0.5 A 50 +5 V1DC 0.4 A 3.0 A 5.0 A 50 +12 V2DC 0.2 A 2.0 A 2.5 A 120 -12 V3DC 0A 0.3 A 0.5 A 120 +5 V1DC 0.4 A 3.0 A 5.0 A 50 +15 V2DC 0.2 A 1.5 A 2.3 A 150 -15 V3DC 0A 0.3 A 0.5 A 150 +5 V1DC 0.4 A 3.0 A 5.0 A 50 +24 V2DC 0.2 A 1.0 A 1.5 A 240 -12 V3DC 0A 0.3 A 0.5 A 120 +5 V1DC 0.4 A 3.0 A 5.0 A 50 +24 V2DC 0.2 A 1.0 A 1.5 A 240 -5 V3DC 0A 0.3 A 0.5 A 50 +5 V1DC 0.4 A 3.0 A 5.0 A 50 +24 V2DC 0.2 A 1.0 A 1.5 A 240 +12 V3DC 0A 0.3 A 0.5 A 120 +3.3V1DC 0.4 A 5.0 A 7.0 A 50 +5 V2DC 0.2 A 2.0 A 3.5 A 50 -12 V3DC 0A 0.3 A 0.5 A 120 OUTPUT POWER MAX. (W) % EFF 40.5 75 42.6 75 42.0 75 42.6 75 40.5 75 42.6 75 30.0 70 *Add a 0.1 F ceramic Capacitor and a 10F E.L. Capacitor to Output for Ripple & Noise measuring at 20 MHz BW. M + R Multitronik GmbH Kaninchenbergweg 78 * 23564 Lubeck * Germany Tel. (+49) 0451 - 60 99 50 * Fax (+49) 0451 - 60 46 95 www.multitronik.com info@multitronik.com vertrieb@mrmultitronik.de 30-40 Watt - AC/DC-Converter - Open Frame - ACS/D/T-Serie 3/7 S P E C I F I C AT I O N S All Specifications Typical At Nominal Line, 75% Load, and 25C Unless Otherwise Noted INPUT SPECIFICATIONS Input Voltage Range 90-264 VAC, 130-370 VDC Single Dual + Triple Input Frequency 47 to 63 Hz 47 to 440 Hz Inrush Current at 264 VAC Input Current at 115 VAC 50 A max. only Dual + Triple 1 A max. (RMS) Single Dual+Triple V1 V2 V3 1% 3% 4% 3% OUTPUT SPECIFICATIONS Voltage Accuracy 1) Ripple and Noise 4) Short Circuit Protection see table Single Dual + Triple Over Load Protection only Dual + Triple Over Voltage Protection only Dual + Triple Continuous V1+V2-Continuous, V 3-no SCP Auto Recovery (On All Outputs) 105-125% Load, Hiccup mode Auto Recovery (On All Outputs) 3.3 V 5V 12V, 15V, 24V 3.6-4.6 VDC 5.7-6.7 VDC 120-140% at V1+V2 5% 10% Adjustment Range Single Dual + Triple Hold-up Time at 115 VAC / 230 VAC Single Dual + Triple 10 mS / 90 mS 20 mS / 70 mS Rise Time at 115 VAC / 230 VAC Single Dual + Triple 2 ms / 3ms 3 ms / 4 ms Set-Up Time at 115 VAC / 230 VAC Single Dual + Triple 1.5 sec / 1 sec 2 sec / 1.5 sec Single 0.05%/C Single Dual + Triple V1 V2 V3 0.5% 1.0% 2.0% 1.0% Single Dual + Triple V1 V2 V3 1.0% 3.0% 5.0% 1.0% Temperature Coefficient Line Regulation 2) Load Regulation 3) 1) Dual + Triple Output: Voltage Accuracy is set at Full Load. 2) Single Output: Line Regulation is measured from High Line to Low Line with Full Load. Dual + Triple Output: Line Regulation is measured from 100 VAC to 240VAC with Full Load. 3) Single Output: Load Regulation is measured from Full Load to 10% Load. Dual + Triple Output: Load Regulation is measured from 60% to 100% Full Load and from 60% to 20% Full Load (60% 40 Full Load) 4) Add a 0.1F ceramic Capacitor and a 10F E.L. Capacitor to Output for Ripple & Noise measuring at 20 MHz BW. M + R Multitronik GmbH Kaninchenbergweg 78 * 23564 Lubeck * Germany Tel. (+49) 0451 - 60 99 50 * Fax (+49) 0451 - 60 46 95 www.multitronik.com info@multitronik.com vertrieb@mrmultitronik.de 30-40 Watt - AC/DC-Converter - Open Frame - ACS/D/T-Serie 4/7 S P E C I F I C AT I O N S All Specifications Typical At Nominal Line, 75% Load, and 25C Unless Otherwise Noted GENERAL SPECIFICATION Efficiency see table Isolation Voltage Input to Output 3000 VAC / 4242 VDC Leakage Current Single Dual + Triple 1.5 mA max. 0.5 mA max. Operating Temperature Range 0C to +45C Derating see Diagrams Storage Temperature Range -20C to +85C Cooling Maximum Power for Convection Cooling With 30 CFM Forced Air Single Free Air Convection only Dual + Triple 40 W (ACT40-3.3/5/12 30W) 50 W (ACT40-3.3/5/12 40W) Conducted EMI CISPR/FCC Class B Single TUV UL CB CE EN60950, 2000 UL 60950, 2000 IEC60950, 1999 EN61000-6-2, 1999 EN55022, EN55024 TUV UL CB CE EN60950, 2000 UL60950-1, 2003 IEC60950, 1999 EN61204-3, 2000 Class B EN55022, EN55024 Safety Dual + Triple Dimensions 101.6 x 50.8 x 30.48 mm Input Connector Output Connector Molex Housing 09-50-3031 Single Dual + Triple M + R Multitronik GmbH Kaninchenbergweg 78 * 23564 Lubeck * Germany Tel. (+49) 0451 - 60 99 50 * Fax (+49) 0451 - 60 46 95 Molex Housing 09-50-3041 Molex Housing 09-50-3061 Crimp 2878 Series www.multitronik.com info@multitronik.com vertrieb@mrmultitronik.de 30-40 Watt - AC/DC-Converter - Open Frame - ACS/D/T-Serie 5/7 S P E C I F I C AT I O N S All Specifications Typical At Nominal Line, 75% Load, and 25C Unless Otherwise Noted MECHANICAL SPECIFICATIONS Single Output PIN CONNECTIONS of Output Pin Single Dual/Triple 1. +Vout Vout2 2. +Vout Vout1 3. -Vout Vout1 4. -Vout COM 5. - COM 6. - Vout3 Dual + Triple Output M + R Multitronik GmbH Kaninchenbergweg 78 * 23564 Lubeck * Germany Tel. (+49) 0451 - 60 99 50 * Fax (+49) 0451 - 60 46 95 www.multitronik.com info@multitronik.com vertrieb@mrmultitronik.de 30-40 Watt - AC/DC-Converter - Open Frame - ACS/D/T-Serie 6/7 S P E C I F I C AT I O N S All Specifications Typical At Nominal Line, 75% Load, and 25C Unless Otherwise Noted BLOCK DIAGRAMS ACS40-xx ACD/T40-xx M + R Multitronik GmbH Kaninchenbergweg 78 * 23564 Lubeck * Germany Tel. (+49) 0451 - 60 99 50 * Fax (+49) 0451 - 60 46 95 www.multitronik.com info@multitronik.com vertrieb@mrmultitronik.de 30-40 Watt - AC/DC-Converter - Open Frame - ACS/D/T-Serie 7/7 S P E C I F I C AT I O N S All Specifications Typical At Nominal Line, 75% Load, and 25C Unless Otherwise Noted DERATING DIAGRAMS ACS40-xx C 0 10 20 30 40 50 55 60 60 70 Load (% ) 100 100 100 100 100 100 90 80 0 0 ACD/T40-xx N O T I C E: The information in this document has been carefully checked. However, no responsibility is assumed for inaccuracies! Specifications can be changed without notice. The latest and most complete information can be found on our website. M + R Multitronik GmbH Kaninchenbergweg 78 * 23564 Lubeck * Germany Tel. (+49) 0451 - 60 99 50 * Fax (+49) 0451 - 60 46 95 www.multitronik.com info@multitronik.com vertrieb@mrmultitronik.de