ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 1 of 35
Member of the Family
Applications
Low voltage, high density systems with
Intermediate Bus A rchitectures (IB A )
Point-of-load regulators for hi gh performance DSP,
FPGA, ASIC, and mi croprocessor appli cations
Desktops, servers, and portable c om puting
Broadband, networking, optical, and
communicati ons system s
Active memory bus terminators
Benefits
Integrates digi tal power conversion with intelligent
power management
Eliminates the need for external power
management components
Completely programmabl e via industry-standard
I2C communication b us
One part that covers all applications
Reduces board space, system cost and
complexity, and tim e to market
Features
RoHS lead free and lead-solder-exempt products are
available
Wide input voltage range: 3V–14V
High continuous out put current: 7A
Wide programmable output voltage range: 0.5V–5.5V
Active digital current share
Single-wire serial communication bus for frequency
synchronization, programming, and mo ni toring
Optimal voltage positioning with progra mmabl e slope
of the VI line
Overcurrent, ov ervolt age, unde rvol tage, and
overtemperature protection with programmable
thresholds and t ypes
Programmabl e fixed switching frequency 0.5-1.0MHz
Programmabl e turn-on and turn-off delays
Programmabl e turn-on and turn-off voltage slew rates
with tracking protection
Programmabl e feedback loop com pensation
Power Good signal with programmable li m i ts
Programmabl e fault management
Start up into the l oad pre-biased up to 100%
Full rated current sin k
Real time voltage, current, and t em perature
measurements, m oni toring, and rep orting
Small footprint SMT package: 12.5x22.2mm
Extremely low profile of 6.5mm
Compatible wit h conv entional pick-and-place
equipment
Wide operating tem perature range
UL 60950-1/CSA 22.2 No. 60950-1-07 Second
Edition, IEC 60950-1: 2005, and EN 60950-1:2006
Description
Power-One’s point-of-load converters are recommended for use with regulated bus converters in an Intermediate
Bus Architecture (IBA). The ZY7007 is an intelligent, fully programmable step-down point-of-load DC-DC module
integrating digital power conversion and intelligent power management. When used with ZM7300 Series Digital
Power Managers, the ZY7007 completely eliminates the need for external components for sequencing, tracking,
protection, monitoring, and reporting. All parameters of the ZY7007 are programmable via the industry-standard
I2C communication b us and can be changed by a user at any time during pro duct development and service.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 2 of 35
Reference Documents:
ZM7300 Digital Power Manager Data Sheet
ZM7300 PrgManual - Digital Power Manager Programming M anual
Power-One I2C GEN II Graphical User I nterface
ZM00056-KIT USB to I2C Adapter Kit. User Manual
1. Ordering Information
ZY 70 07 x y zz
Product
family:
Z-One
Module
Series:
Intelligent
POL
Converter
Output
Current:
7A
Output voltage setpoint
accuracy:
L1.2% or 20mV,
whichever is greater.
H11.0% or 10mV,
whichever is greater
RoHS compliance:
No suffix - RoHS
compliant with Pb
solder exemption2
G - RoHS compliant
for all six substances
Dash
Packaging Option
3
:
T1 - 500pcs T&R
T2100pcs T&R
T350pcs T&R
Q11pc sample for
evaluation only
______________________________________
1 Contact factory for availability.
2 The solder exemption refers to all the restricted materials except lead in solder. These materials are Cadmium (Cd), Hexavalent chromium
(Cr6+), Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylethers (PBDE), and Lead (Pb) used anywhere except in
solder.
3 Packaging option is used only for ordering and not included in the part number printed on the POL converter label.
4 The evaluation board is available in only one configuration: ZM7300-KIT-HKS.
Example: ZY7007HG-T2: A 100-piece reel of RoHS compliant POL converters with the output voltage setpoint of
1.0% or 10mV, whichever is greater. Each POL converter is labeled ZY7007HG.
2. Absolute Maximum Ratin gs
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-
term reliability, and cause permanent damage to the converter.
Parameter Conditions/Description Min Max Units
Operating Temperature C ontroller cas e temperature -40 105 °C
Input Voltage 250ms Transient 15 VDC
Output Current (See Output Current De-rating Curves) -7 7 ADC
3. Environmental and Mechanical Specif ications
Parameter Conditions/Description Min Nom Max Units
Ambient Temperature Range -40 85 °C
Storage Temper ature (Ts) -55 125 °C
Weight 8 grams
MTBF Calculated Per Telcordia Technologies S R-332 6.24 MHrs
Peak Reflow Temperature ZY7007
ZY7007G
245 220
260 °C
°
C
Lead Plating ZY7007 and ZY7007G 100% Matte Tin
Moisture Sensitivity Level ZY7007 and ZY7007G 3
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 3 of 35
4. Electrical Specifications
Specifications apply at the input voltage from 3V to 14V, output load from 0 to 7A, ambient temperature from -40°C to 85°C,
100µF output capacitance, and default performance parameters settings unless other wise noted.
4.1 Input Specifications
Parameter Conditions/Description Min Nom Max Units
Input voltage (VIN)
At V
IN
<4.75V, VLDO pin needs to be
connected to an external voltage source
higher than 4.75V
3 14 VDC
Input Current (at no load) VIN4.75V, VLDO pin con nected to VIN 50 mADC
Undervoltage Lockout (VLDO
connected to VIN) Ramping Up
Ramping Down 4.2
3.75 VDC
VDC
Undervoltage Lockout (VLDO
connected to VAUX=5V) Ramping Up
Ramping Down 3.0
2.5 VDC
VDC
External Low Voltage Supply Connect t o V LDO pin when VIN<4.75V 4.75 14 VDC
VLDO Input Current Current dr awn from the external low
voltage supply at VLDO=5V 50 mADC
4.2 Output Specifications
Parameter Conditions/Description Min Nom Max Units
Output Voltage Range (VOUT) Programmable
1
0.5
Default (no programming)
0.5 5.5
VDC
VDC
Output Voltage Setpoint Accuracy
V
IN
=12V, I
OUT
=0.5*I
OUT MAX
,
FSW=500kHz, room temperature
(See Ordering Infor mati on)
Output Current (IOUT) VIN MIN to VIN MAX -72 7 ADC
Line Regulat i on VIN MIN to VIN MAX ±0.3 %VOUT
Load Regulat ion 0 to IOUT MAX ±0.3 %VOUT
Dynamic Regulation
Peak Deviation
Settling Ti m e
Slew rate 2.5A/µs, 50 - 100% load step
COUT=220µF, FSW=1MHz
to 10% of peak deviation
50
50
mV
µs
Output Voltage Peak-to-Peak
Ripple and Noise
BW=20MHz
Full Load
VIN=5.0V, VOUT=0.5V, FSW=500kHz
VIN=5.0V, VOUT=2.5V, FSW=500kHz
VIN=13.2V, VOUT=0.5V, FSW=500kHz
VIN=13.2V, VOUT=2.5V, FSW=500kHz
VIN=13.2V, VOUT=5.0V, FSW=500kHz
VIN=13.2V, VOUT=5.0V, FSW=1MHz
15
15
20
25
40
20
mV
mV
mV
mV
mV
mV
Temperature Coefficient VIN=12V, IOUT=0.5*IO UT MAX 20 ppm/°C
Switching Fr equency Default
Programmable, 250kHz steps
500 500
1,000 kHz
kHz
Duty Cycle L imit Default
Programmable, 1.56% steps
0 90.5
95 %
%
1 ZY7007 is a step-down converter, thus the output voltage is always lower than the input voltage as show in Figure 1.
2 At the negative output current (bus terminator mode) efficiency of the ZY7007 degrades resulting in increased internal power dissipation.
Therefore maximum allowable negative current under specific conditions is 20% lower than the current determined from the derating curves
shown in paragraph 5.5.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 4 of 35
Figure 1. Output Voltage as a Function of Input Voltage and Output Current
4.3 Protection Specifications
Parameter Conditions/Description Min Nom Max Units
Output Overcurrent Protection
Type Default
Programmable Non-Latching, 130ms period
Latching/Non-Latching
Threshold Default
Programmable in 11 steps
60 180
180 %IOUT
%IOUT
Threshold Accuracy -25 25 %IOCP.SET
Output Overvoltage Protection
Type Default
Programmable Non-Latching, 130ms period
Latching/Non-Latching
Threshold Default
Programmable in 10% steps
1101 130
130 %VO.SET
%VO.SET
Threshold Accuracy Meas ured at VO.SET=2.5V -2 2 %VOVP.SET
Delay From instant when threshold is exceeded until
the turn-off com mand is generated 6 μs
___________________
1 Minimum OVP threshold is 1.0V
5.0
4.0
3.0
2.0
1.0
V
OUT
[V]
12.0
10.0
8.0
6.0
2.0
4.0
Minimum Load 0.25A
V
IN
[V]
3.0
3.3
5.5
2.5
5.5
4.5
3.5
1.5
0.5
6.25
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 5 of 35
Output Undervoltage Protection
Type Default
Programmable Non-Latching, 130ms period
Latching/Non-Latching
Threshold Default
Programmable in 5% steps
75 75
85 %VO.SET
%VO.SET
Threshold Accuracy Meas ured at VO.SET=2.5V -2 2 %VUVP.SET
Delay From instant when threshold is exceeded until
the turn-off com mand is generated 6 μs
Over Tem perature Protection
Type Default
Programmable Non-Latching, 130ms period
Latching/Non-Latching
Turn Off Threshold Temper ature is increasing 130 °C
Turn On Threshold
Temperature is decreasing after the m odule wa s
shut down by OTP
120 °C
Threshold Accuracy -5 5 °C
Delay
From instant when threshold is exceeded until
the turn-off command is generat ed
6 μs
Tracking Prot ect ion (when Enabled)
Type Default
Programmable Disabled
Latching/Non-Latching, 130m s period
Threshold Enabled during output volta ge ramping up ±250 mVDC
Threshold Accuracy -50 50 mVDC
Delay From instant when threshold is exceeded until
the turn-off com mand is generated 6 μs
Over Temperature Warning
Threshold Always enabled, reported in Status register 120 °C
Threshold Accuracy -5 5 °C
Hysteresis 3 °C
Delay From instant when threshold is exceeded until
the warning si gnal is generat ed
6 μs
Power Good Signal (PGOOD pin)
Logic
V
OUT
is inside the PG window
VOUT is outside the PG window
High
Low
N/A
Lower Threshold Default
Programmable in 5% steps
90 90
95 %VO.SET
%VO.SET
Upper Thres hol d 110 %VO.SET
Delay From instant when threshold is exceeded until
status of PG signal changes
6 μs
Threshold Accuracy Meas ured at VO.SET=2.5V -2 2 %VO.SET
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 6 of 35
4.4 Feature Specifications
Parameter Conditions/Description Min Nom Max Units
Current Share
Type Active, Single Line
Maximum Number of Modules
Connected in Parallel IOUT MIN=0 4
Current Share Accuracy IOUT MIN≥20%*IOUT NOM ±20 %IOUT
Interleave
Interleave (Phase Shift)
Default
Programmable in 11.25
°
steps
0
0
348.75
Degree
degree
Sequencing
Turn ON Delay Default
Programmable in 1ms steps
0 0
255 ms
ms
Turn OFF Delay Default
Programmable in 1ms steps
0 0
63 ms
ms
Tracking
Turn ON Slew Rate Default
Programmable in 7 steps
0.1 0.1
8.331 V/ms
V/ms
Turn OFF Slew Rate Default
Programmable in 7 steps
-0.1 -0.1
-8.331 V/ms
V/ms
Optimal Voltage Positioning
Load Regulat ion Default
Programmable in 7 steps
0 0
13 mV/A
mV/A
Feedback Loop Compensation
Zero1 (Effects phase lead an d
increases gai n in mid-band) Programmable 0.05 50 kHz
Zero 2 (Effects phase lead an d
increases gai n in mid-band) Programmable 0.05 50 kHz
Pole 1 (Integrator Pole, effect s
loop gain) Programmable 0.05 50 kHz
Pole 2 (Effect s phase lag and
limits gain in mid-band) Programmable 1 1000 kHz
Pole 3 (High frequency low- pass
filter to limit PWM noise) Programmable 1 1000 kHz
Monitoring
Voltage Monitoring Accuracy 1 LSB= 22m V -2%VOUT
– 1 LSB 2%VOUT
+ 1 LSB mV
Current Monit oring Accuracy 20%*IOUT NOM < IOUT < IOUT NOM -20 +20 %IOUT
Temperature M oni toring Accuracy Junct ion temperatur e of POL controll er -5 +5 °C
Remote Voltage Sense (+VS an d VS pins)
Voltage Drop C om pensation Between +VS and V OUT 300 mV
Voltage Drop C om pensation Between -VS and PGND 100 mV
___________________
1 Achieving fast slew rates under specific line and load conditions may require feedback loop adjustment
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 7 of 35
4.5 Signal Specifications
Parameter Conditions/Description Min Nom Max Units
VDD Internal supply voltag e 3.15 3.3 3.45 V
SYNC/DATA Line (SD pin)
ViL_sd LOW level input v ol tage -0.5 0.3 x VDD V
ViH_sd HIGH level input volt age 0.75 x
VDD
VDD + 0.5 V
Vhyst_sd Hysteresis of input Schmitt trigger
0.25 x
VDD
0.45 x
VDD
V
VoL LOW level s i nk current @ 0.5V 14 60 mA
Tr_sd Maximum allowed rise time 10/90%VDD 300 ns
Cnode_sd A dded node capacit ance 5 10 pF
Ipu_sd Pull-u p c urrent source at V sd=0V 0.3 1.0 mA
Freq_sd Clock f requency of external SD line 475 525 kHz
Tsynq Sync pulse duration 22 28
% of clock
cycle
T0 Data=0 pulse duratio n 72 78
% of clock
cycle
Inputs: ADDR0…ADDR4, EN, IM
ViL_x LOW lev el input voltage -0.5 0.3 x VDD V
ViH_x HIGH level input voltage 0.7 x VDD VDD+0.5 V
Vhyst_x Hysteresis of input Schmitt trigger 0.1 x VD D 0.3 x VDD V
RdnL_ADDR
External pull down resistance
ADDRX forced low
10 kOhm
Power Good and OK Inputs/Out puts
Iup_PG Pull-up current sour c e input forced l ow PG 25 110 μA
Iup_OK Pull-up cur r ent source input forced low OK 175 725 μA
ViL_x LOW lev el input voltage -0.5 0.3 x VDD V
ViH_x HIGH level input voltage 0.7 x VDD VDD+0.5 V
Vhyst_x Hysteresis of input Schmitt trigger 0.1 x VD D 0.3 x VDD V
IoL LOW level s i nk current at 0. 5V 4 20 mA
Current Share Bus (CS pin )
Iup_CS Pull-u p c urrent source at V C S = 0V 0.84 3.1 mA
ViL_CS LOW level input volt age -0.5 0.3 x VDD V
ViH_CS HIGH level input voltage 0.75 x
VDD
VDD+0.5 V
Vhyst_CS Hysteresis of input Schmit t trigger
0.25 x
VDD
0.45 x
VDD
V
IoL LOW level s i nk current at 0. 5V 14 60 mA
Tr_CS Maximum allowed rise time 10/90% VD D 100 ns
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 8 of 35
5. Typical Performan ce Char acteri s tics
5.1 Efficiency Curves
55
60
65
70
75
80
85
90
95
01234567
O ut put Cur r ent , A
Eff i ci ency, %
Vo=0.5V Vo=1.2V Vo=2.5V
Figure 2. Effic ie ncy vs. Load. Vin=3.3V, Fsw=500kHz
60
65
70
75
80
85
90
95
01234567
O ut put Cur r ent , A
Eff i ci ency, %
Vo=0.5V Vo=1.2V
Vo=2.5V Vo=3.3V
Figure 3. Effic ie ncy vs. Load. Vin=5V, Fsw=500kHz
74
76
78
80
82
84
86
88
90
92
94
01234567
O ut put Cur r ent , A
Eff i ci ency, %
Vo=1.2V Vo=2.5V
Vo=3.3V Vo=5.0V
Figure 4. Effic ie ncy vs. Load. Vin=9.6V, Fsw=500kHz
70
72
74
76
78
80
82
84
86
88
90
92
0 1 2 3 4 5 6 7
O ut put Cur r ent , A
Eff i ci ency, %
Vo=1.2V Vo=2.5V
Vo=3.3V Vo=5.0V
Figure 5. Effic ie ncy vs. Load. Vin=12V, Fsw=500kHz
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 9 of 35
55
60
65
70
75
80
85
90
95
0.5 1.5 2.5 3.5 4.5 5.5
O ut put Volt age, V
Eff i ci ency, %
Vin=5V Vin=3.3V
Vin=9.6V Vin=12V
Figure 6. Effic ie ncy vs. Output Voltage, Iout= 7A, Fsw=500kHz
50
55
60
65
70
75
80
85
90
345678910 11 12 13 14
I nput Vol tage, V
Eff i ci ency, %
Vo=0.5V Vo=1.2V Vo=2.5V
Figure 7. Efficiency vs. Input Voltage. Iout=7A, Fsw=500kHz
5.2 Turn-On Charact eristics
Figure 8. Tracking Turn-On. Rising Slew Rate is Programmed
at 0.5V/ms.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 V3
Figure 9. Turn-On with Different Rising Slew Rates.
Rising Slew Rates are Programmed as follows: V1-
1V/ms, V2-0.5V/ms, V3-0.2V/ms.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 V3
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 10 of 35
Figure 10. Sequ enc ed Tur n-On. Rising Slew Rate is
Programmed at 1V /ms. V2 Delay is 2ms, V3 delay
is 4ms. Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3
Figure 11. Turn On into Prebiased Load. V3 is Prebiased by
V2 via a Diode.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 V3
5.3 Turn-Off Characteri stics
Figure 12. Tracking Turn-Off. Falling Slew Rate is
Programmed at 0.5V/ms.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 V3
Figure 13. Turn-Off with Tracking and Sequencing. Falling
Slew Rate is Programmed at 0.5V/ms.
Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 V3
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 11 of 35
5.4 Transient Response
The pictures below show the deviation of the output
voltage in response to the 50-100-50% step load at
2.5A/μs. In all tests the POL converters were
switching at 1MHz and had 10 x 22μF ceramic
capacitors connected across the output pins.
Bandwidth of the feedback loop was programmed for
faster transie nt response.
Figure 14. Vin=12V, Vout=5V, BW~50kHz
Figure 15. Vin=12V, Vout=1V, BW~40kHz
Figure 16. Vin=5V, Vout=2.5V, BW~40kHz
Figure 17. Vin=5V, Vout=1V, BW~ 40kHz
Figure 18. Vin=3.3V, Vout=1V, BW~40kHz
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 12 of 35
5.5 Thermal De-rating Curves
Figure 19. Thermal Derating Curves. Vin=12V, V out=5.0V, Fsw=500kHz
3
3.5
4
4.5
5
5.5
6
6.5
7
45 55 65 75 85
Am bient Temperat ure, Degree C
Output C urrent , A
0LFM 100LFM 200LFM 400LFM 600LFM
Figure 20. Thermal Derating Curves. Vin=14V, Vout=5 .0V , F sw=500kHz
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 13 of 35
3
3.5
4
4.5
5
5.5
6
6.5
7
45 55 65 75 85
A m bi ent Tem perat ur e, Degree 'C
O ut put Curr e nt , A
0LFM 100LFM 200LFM 400LFM 600LFM
Figure 21. Thermal Derating Curves. Vin=12V, Vout=5.0V, Fsw=1MHz
3
3.5
4
4.5
5
5.5
6
6.5
7
45 55 65 75 85
A m bi ent Tem perat ur e, Degree 'C
O ut put Curr e nt , A
0LFM 100LFM 200LFM 400LFM 600LFM
Figure 22. Thermal Derating Curves. Vin=14V, Vout=5.0V, Fsw=1MHz
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 14 of 35
6. Typical Application
ZY7007
V1
V2
V3
CS
SD
OK_A
OK_B
ADDR
ADDR
ADDR
ADDR
DPM
I
2
C
Intermediate Voltage Bus
ZY7007
ZY7007
ZY7007
OK_C
Figure 23. Block Diagram of Typical Multiple Output Application with Digital Power Manager and I2C Interface
The block diagram of a typical application of ZY7007 point-of-load converters (POL) is shown in Figure 23. The
system includes multiple POLs and a ZM7300 series Digital Power Manager (DPM). All POLs are connected to the
DPM and to each other via a single-wire SD (sync/data) line. The line provides synchronization of all POLs to the
master clock generated by the DPM and simultaneously performs bidirectional data transfer between POLs and
the DPM. Each POL has a unique 5-bit address pr ogrammed by grounding respective address pins. To enable the
current share, CS pi ns of P O Ls connected in paral lel are linked together.
There are three groups of POLs in the application, groups A, B, and group C. A group is defined as a number of
POLs interconnected via OK pins. Grouping of POLs enables users to program, control, and monitor multiple
POLs simultaneously and execute advanced fault managem ent schemes.
The complete schem atic of the applic ation is shown in Figure 24.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 15 of 35
Figure 24. Complete Schematic of the Application Shown in Figure 23. Intermediate Bus Voltage is from 4.75V to 13.2V.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 16 of 35
7. Pin Assignments and Descriptions
Pin
Name Pin
Number Pin
Type Buffer
Type Pin Description Notes
VLDO 1 P Low Voltage Dropout
Connect to an external voltage source hi gher than
4.75V, if VIN<4.75V. Connect to VIN, if VIN≥4.75V
NC 2 Not Used Leave floating
NC 3 Not Used Leave floating
NC 4 Not Used Leave floating
ADDR0 5 I PU POL Address Bit 0 Tie to PGND for 0 or leave floating for 1
ADDR1 6 I PU POL Address Bit 1 Tie to PGND for 0 or leave floating for 1
ADDR2 7 I PU POL Address Bit 2 Tie to PGND for 0 or leave floating for 1
ADDR3 8 I PU POL Address Bit 3 Tie to PGND for 0 or leave floating for 1
ADDR4 9 I PU POL Address Bit 4 Tie to PGND for 0 or leave floating for 1
CS 10 I/O PU Curr ent Share
Connect to CS pins of other Z-POLs connected in
parallel
TRIM 11 Not Used Leave floati ng
PGOOD 12 I/O PU Power Good
SD 13 I/O PU Sync/Data Line Con nec t to SD pin of DPM
OK 14 I/O PU Fault/Status Condit i on Connect to OK pin of other Z-POLs and/or DPM.
Leave floating, if not used
EN 15 Connect to PGND Connect to PGND
VREF 16 Not Used Leave floating
IM 17 Not Used Leave floating
NC 18 Not Used Leave floating
VOUT 19-23 P Output Voltag e
+VS 24 I PU Positive V oltage Sense C onnect to the posit i ve point close to the load
PGND 25-30 P Power Ground
-VS 31 I PU Negative Voltage Sense Connect to the negat i v e point close t o the load
VIN 32-36 P Input Voltage
Legend: I=input, O=output, I/O=input/output, P=power, A=analog, PU=internal pull-up
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 17 of 35
8. Programmable Features
Performance parameters of ZY7007 POL converters
can be programmed via the industry standard I2C
communication bus without replacing any
components or rewiring PCB traces . Each parameter
has a default value stored in the volatile memory
registers detailed in Table 1. The setup registers 00h
through 14h are programmed at the system power-
up. When the user programs new performance
parameters, the values in the registers are
overwritten. Upon removal of the input voltage, the
default values are restored.
Table 1. ZY7007 Memory Registers
Register Content Address
PC1
Protection C onfiguration 1
00h
PC2
Protection C onfiguration 2
01h
PC3
Protection C onfiguration 3
02h
DON
Turn-On Delay
05h
DOF
Turn-Off Delay
06h
TC
Tracking Conf iguration
03h
INT
Interleave Configuration and
Frequency Selection
04h
RUN
RUN Register
15h
ST
Status Register
16h
VOS
Output Voltage Setpoint
07h
CLS
Current Limit Setpoint
08h
DCL
Duty Cycle Limit
09h
B1
Dig Controller Denominator z-1
Coefficient
0Ah
B2 Dig Controller Denominator z
-2
Coefficient
0Bh
B3 Dig Controller Denominator z
-3
Coefficient
0Ch
C0L
Dig Controller Numerator z0
Coefficient , Low Byte
0Dh
C0H
Dig Controller Numerator z0
Coefficient , High Byte
0Eh
C1L
Dig Controller Numerator z-1
Coefficient , Low Byte
0Fh
C1H Dig Controller Numerator z
-1
Coefficient , High Byte
10h
C2L Dig Controller Numerator z
-2
Coefficient , Low Byte
11h
C2H
Dig Controller Numerator z-2
Coefficient , High Byte
12h
C3L
Dig Controller Numerator z -3
Coefficient , High Byte
13h
C3H
Dig Controller Numerator z-3
Coefficient , Low Byte
14h
VOM
Output Voltage Monitoring
17h
IOM
Output Current Monitoring
18h
TMP
Temperature M oni toring
19h
ZY7007 converters can be programmed using the
Graphical User Interface or directly via the I2C bu s by
using high and low level commands as described in
the ”ZM7300 Programming Manual”.
ZY7007 parameters can be reprogrammed at any
time during the system operation and service except
for the digital filter coefficients, the switching
frequency and the duty cycle limit, that can only be
changed when t he P O L i s turned off.
8.1 Output Voltage
The output voltage can be programmed in the POL
Output Configure window shown in the Figure 25 or
directly via the I2C bus by writing into the VOS
register shown in Figure 26.
Figure 25. Output Configuration Window
VOS7
VOS6
VOS5
VOS4
VOS2
VOS1
VOS0
Bit 7
Bit 0
R = Readable bit
W = Writable bit
U = Unimplemented bit,
read as ‘0’
- n = Value at POR reset
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
Bit 7:0 VOS[7:0], Output voltage setting
00h: corresponds to 0. 5 000 V
01h: corresponds to 0. 5 125 V
77h: corresponds to 1. 9 875 V
78h: corresponds to 2. 0 000 V
79h: corresponds to 2. 0 25V
F9h: corresponds to 5.225V
FAh: corresponds to 5.250V
FBh: corresponds to 5.300V
FFh: corresponds to 5.500V
VOS3
Figure 26. Output Voltage Setpoint Register VOS
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 18 of 35
8.1.1 Output Voltage Setpoint
The output voltage programming range is from 0.5V
to 5.5V. Within this range, there are 256 predefined
voltage set points. To improve resolution of the
output voltage settings, the voltage range is divided
into three sub-ranges as shown in Table 2.
Table 2. Output Voltage Adjustment Resolution
VOUT MIN, V VOUT MAX, V Resolution, mV
0.500 2.000 12.5
2.025 5.25 25
5.3 5.5 50
8.1.2 Output Voltage Margining
If the output voltage needs to be varied by a certain
percentage, the margining function can be utilized.
The margining can be programmed in the POL
Configuration window or directly via the I2C bus
using high level commands as described in the
ZM7300 Digital Power Manager Programming
Manual”.
In order to properly margin POLs that are connected
in parallel, the POLs must be members of one of the
Parallel Buses. Refer to the DPM Configure Devices
window shown in Figure 53.
8.1.3 Optimal Voltage Positioning
Optimal voltage positioning increases the voltage
regulation window by properly positioning the output
voltage setpoint. Positioning is determined by the
load regulation that can be programmed in the POL
Configure Output window shown in Figure 25 or
directly via the I2C bus by writing into the CLS
register shown in Figure 36.
Figure 27 illustrates optimal voltage positioning
concept. If no load regulation is programmed, the
headroom (voltage differential between the output
voltage setpoint and a regulation limit) is
approximately half of the voltage regulation window.
When load regulation is programmed, the output
voltage will decrease as the output current
increases, so the VI characteristic will have a
negative slope. Therefore, by properly selecting the
operating point, it is possible to increase the
headroom as shown in the picture.
Upper Regulation
Limit
Lower Regulation
Limit
Light
Load
V
OUT
I
OUT
VI Curve Without
Load Regulation
VI Cur v e With
Load Regulation
Heavy
Load
Headroom without
Load Regulation
Operating
Point
Headroom with
Load Regulation
Figure 27. Optimal Voltage Positioning Concept
Increased headroom allows tolerating larger voltage
deviations. For example, the step load change from
light to heavy load will cause the output voltage to
drop. If the optimal voltage positioning is utilized, the
output voltage will stay within the regulation window.
Otherwise, the output voltage will drop below the
lower regulation limit. To compensate for the voltage
drop external output capacitance will need to be
added, thus increasing cost and complexity of the
system.
The effect of optimal voltage positioning is shown in
Figure 28 and Figure 29. In this case, switching
output load causes large peak-to-peak deviation of
the output voltage. By programming load regulation,
the peak to peak devi ation is dramatically reduced.
Figure 28. Transient Response without Optimal Voltage
Positioning
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 19 of 35
Figure 29. Transient Response with Optimal Voltage
Positioning
8.2 Sequencing and Tracking
Turn-on delay, turn-off delay, and rising and falling
output voltage slew rates can be programmed in the
POL Configure Sequencing window shown in Figure
30 or directly via the I2C bus by writing into the DON,
DOF, and TC registers, respectively. The registers
are shown in Figure 31, Figure 32, and Figure 34.
Figure 30. POL Con figure Sequencing Window
8.2.1 Turn-On Delay
Turn-on delay is defined as an interval from the
application of the Turn-On command until the output
voltage starts rampi ng up.
DON7
DON6
DON5
DON4
DON2
DON1
DON0
Bit 7
Bit 0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
Bit 7:0 DON[7:0]: Turn-on delay time
00h: corresponds to 0ms delay after turn-on command has occurred
FFh: corresponds to 255ms delay after turn-on command has occurred
DON3
Figure 31. Turn-On Delay Register DON
8.2.2 Turn-Off Delay
---
---
DOF5
DOF4
DOF2
DOF1
DOF0
Bit 7
Bit 0
U
U
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
Bit 7:6 Unimplemented, read as ‘0’
Bit 5:0 DOF[5:0]: Turn- o ff delay time
00h: corresponds to 0ms delay after turn-off command has occurred
3Fh: corresponds to 63ms delay after turn-off command has occurred
DOF3
Figure 32. Turn-Off Delay Register DOF
Turn-off delay is defined as an interval from the
application of the Turn-Off command until the output
voltage reaches zero (if the falling slew rate is
programmed) or until both high side and low side
switches are turned off (if the slew rate is not
programmed). Therefore, for the slew rate controlled
turn-off the ramp-down time is included in the turn-off
delay as shown in Figure 33.
Turn-Off
Command
Internal
ramp-down
command
VOUT
User programmed turn-off delay, TDF
Calculated
delay TD
Time
Ramp-down time, TF
Falling slew
rate dVF/dT
Figure 33. Relationship between Turn-Off Delay and Falling
Slew Rate
As it can be seen from the figure, the internally
calculated delay TD is determined by the equation
below.
dT
dV
V
TT F
OUT
DFD= ,
For proper operation TD shall be greater than zero.
The appropriate value of the turn-off delay needs to
be programmed t o sat isf y the condition.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 20 of 35
If the falling slew rate control is not utilized, the turn-
off delay only determines an interval from the
application of the Turn-Off command until both high
side and low side switches are turned off. In this
case, the output voltage ramp-down process is
determined by l oad parameters.
8.2.3 Rising and Falling Slew Rates
The output voltage tracking is accomplished by
programming the rising and falling slew rates of the
output voltage. To achieve programmed slew rates,
the output voltage is being changed in 12.5mV steps
where duration of each step determines the slew
rate. For example, ramping up a 1.0V output with a
slew rate of 0.5V/ms will require 80 steps duration of
25μs each.
Duration of each voltage step is calculated by
dividing the master clock frequency generated by the
DPM. Since all POLs in the system are s ynchronized
to the master clock, the matching of voltage slew
rates of different outputs is very accurate as it c an be
seen in Figure 8 and Figure 12.
During the turn on process, a POL not only delivers
current required by the load (ILOAD), but also charges
the load capacitance. The charging current can be
determined from the equation below:
dt
dV
CI
R
LOADCHG
×=
Where, CLOAD is load capacitance, dVR/dt is rising
voltage slew rat e, and ICHG is charging curre nt.
When selecting the rising slew rate, a user needs to
ensure that
OCPCHGLOAD III <+
Where IOCP is the overcurrent protection threshold of
the ZY7007. If the condition is not met, then the
overcurrent protection will be triggered during the
turn-on process. To avoid this, dVR/dt and the
overcurrent protection threshold should be
programmed t o m eet the condition above.
Figure 34. Tracking Configuration Register TC
8.3 Fault and Error Protection
ZY7007 Series converters have a comprehensive set
of programmable fault and error protection
provisions. The set includes the output over- and
undervoltage protection, overcurrent protection,
overtemperature protection, tracking protection,
overtemperature warning, and Power Good signal.
Status of protection logic is stored in the ST register
shown in Figure 35.
Figure 35. Protection Status Register ST
Thresholds of overcurrent, over- and undervoltage
protection responses, and Power Good limits can be
programmed in the POL Configure Output window or
directly via the I2C bus by writing into the CLS and
PC2 registers sho wn in Figure 36 and Figure 37.
---
R2
R1
R0
F2
F1
F0
Bit 7
Bit 0
R
=
Readable bit
W
=
Writable bit
U
=
Unimplemented bit,
read as ‘0’
-
n
=
Value at POR reset
U
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-1
Bit 7
Unimplemented
, read as ‘0’
Bit 6:4
R[2:0]
: Value of Vo rising slope
0: corresponds to 0.1V/ms (default)
1: corresponds to 0.2V/ms
2: corresponds to 0.5V/ms
3: corresponds to 1.0V/ms
4: corresponds to 2.0V/ms
5: corresponds to 5.0V/ms
6: corresponds to 8.3V/ms
7: corresponds to 8.3V/ms
Bit 3
SC
, Slew rate control at turn-off
0: Slew rate control is disabled
1: Slew rate control is enabled
Bit 2:0
F[2:0]
: Value of Vo falling slope
0: corresponds to -0.1V/ms (default)
1: corresponds to -0.2V/ms
2: corresponds to -0.5V/ms
3: corresp
onds to -1.0V/ms
4: corresponds to -2.0V/ms
5: corresponds to -5.0V/ms
6: corresponds to 8.3V/ms
7: corresponds to –8.3V/ms
SC
TP
PG
TR
OT
UV
OV
PV
Bit 7
Bit 0
R
=
Readable bit
W
=
Writable bit
U
=
Unimplemented bit,
read as ‘0’
-
n
=
Value at POR reset
R-1
R-0
R-1
R-1
R-1
R-1
R-1
R-1
Bit 7
TP
: Temperature Warning
Bit 6
PG
: Power Good Warning
Bit 5
TR
: Tracking Fault
Bit 4
OT
: Overtemperature Fault
Bit 3
OC
: Overcurrent Fault
Bit 2
UV
: Undervoltage Fault
Bit 1
OV
: Overvoltage Error
Bit 0
PV
: Phase Voltage Error
Note:
- An activated warning/fault/error is encoded as ‘0’
OC
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 21 of 35
LR2
LR1
LR0
TCE
CLS2
CLS1
CLS0
Bit 7
Bit 0
R = Readable bit
W = Writable bit
U = Unimplemented bit,
read as ‘0’
- n = Value at POR reset
R/W-0
R/W-0
R/W-0
R/W-1
R/W-0
R/W-1
R/W-1
R/W-1
Bit 7:5 LR[2:0], Load regulation configuration
000: 0 V/A/Ohm
001: 0.39 V/A/Ohm
010: 0.78 V/A/Ohm
011: 1.18 V/A/Ohm
100: 1.57 V/A/Ohm
101: 1.96 V/A/Ohm
110: 2.35 V/A/Ohm
111: 2.75 V/A/Ohm
Bit 4 TCE, Temperature compensation enable
0: disabled
1: enabled
Bit 3:0 CLS[3:0], Current limit setting
0h: corresponds to 37%
1h: corresponds to 47%
Bh: corresponds to 140%
Values higher than Bh are translated to Bh (140%)
CLS3
Figure 36. Current Limit Setpoint Register CLS
---
---
---
PGLL
OVPL0
UVPL1
UVPL0
Bit 7
Bit 0
R = Readable bit
W = Writable bit
U = Unimplemented bit,
read as ‘0’
- n = Value at POR reset
U
U
U
R/W-0
R/W-0
R/W-0
R/W-0
R/W-1
Bit 7:5 Unimplemented, read as ‘0’
Bit 4 PGLL: Set Power Good Low Level
1 = 95% of Vo
0 = 90% of Vo (Default)
Bit 3:2 OVPL[1:0]: Set Over Voltage Protection
Level
00 = 110% of Vo
01 = 120% of Vo
10 = 130% of Vo (Default)
11 = 130% of Vo
Bit 1:0 UVPL[1:0]: Set Under Voltage Protection Level
00 = 75% of Vo (Default)
01 = 80% of Vo
10 = 85% of Vo
OVPL1
Figure 37. Protection Configuration Register PC2
Note that the overvoltage and undervoltage
protection thresholds and Power Good limits are
defined as percentages of the output voltage.
Therefore, the absolute levels of the thresholds
change when the output voltage setpoint is changed
either by output voltage adjustment or by margining.
In addition, a user can change protection between
latching and non-latching, or disable certain
protection responses entirely. These settings are
programmed in the POL Configure Fault window
shown in Figure 38 or directly via the I2C by writing
into the PC1 register shown in Figure 39.
Figure 38. POL Configure Fault Window
Figure 39. Protection Configuration Register PC1
If the non-latching protection is selected, a POL will
attempt to restart every 130ms until the condition
that triggered the protection is removed. When
restarting, the output voltages follow tracking and
sequencing settings.
If the latching type is selec ted, a POL will turn off and
stay off. The POL can be turned on after 130ms, if
the condition that caused the fault is removed and
the respective bit in the ST register was cleared, or
the Turn On command was recycled, or the input
voltage was recycled.
TRE
PVE
TRP
OTP
UVP
OVP
PVP
Bit 7
Bit 0
R
=
Readable bit
W
=
Writable bit
U
=
Unimplemented bit,
read as ‘0’
-
n
=
Value at POR reset
R/W-0
R/W-1
R/W-0
R/W-0
R/W-0
R/W-1
R/W-1
R/W-0
Bit 7
TRE
: Tracking fault enable
1 = enabled
0 = disabled
Bit 6
PVE
: Phase voltage error enable
1 = enabled
0 = disabled
Bit 5
TRP
: Tracking fault protection
1 = latching
0 = non latching
Bit 4
OTP
: Overtemperature protection configuration
1 = latching
0 = non latching
Bit 3
OCP
: Overcurrent protection configuration
1 = latching
0 = non latching
Bit 2
UVP
: Undervoltage protection configuration
1 = latching
0 = non latching
Bit 1
OVP
: Overvoltage protection configuration
1 = latching
0 = non latching
Bit 0
PVP
: Phase Voltage Protection
1 = latching
0 = non latching
OCP
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 22 of 35
All protection functions can be classified into three
groups based on their effect on system operation:
warnings, faul ts, and errors.
8.3.1 Warnings
This group includes Overtemperature Warning and
Power Good Signal. The warnings do not turn off
POLs but rather generate signals that can be
transmitted to a host controller via the I2C bus.
8.3.1.1 Overtemperature Warning
The Overtemperature Warning is generated when
temperature of the controller exceeds 120°C. The
Overtemperature Warning changes the PT bit of the
status register ST to 0 and sends the signal to the
DPM. Reporting is enabled in the DPM Configuration
Fault management window or directly via the I2C by
writing into the PC3 register shown in Figure 41.
When the temperature falls below 117°C, the PT bit
is cleared and the Overtemperature Warning is
removed.
8.3.1.2 Power Good
Power Good is an open collector output that is pulled
low, if the output voltage is outside of the Power
Good window. The window is formed by the Power
Good High threshold that is equal to 110% of the
output voltage and the Power Good Low threshold
that can be programmed at 90 or 95% of the output
voltage.
The Power Good protection is only enabled after the
output voltage reaches its steady state level . The PG
pin is pulled low during transitions of the output
voltage from one level to other as shown in Figure
40.
The Power Good Warning pulls the Power Good pin
low and changes the PG bit of the status register ST
to 0. It sen ds the signal to the DPM, if the reporting is
enabled. When the output voltage returns within the
Power Good window, the PG pin is pulled high, the
PG bit is cleared and the Power Good Warning is
removed. The Power Good pin can also be pulled
low by an external circuit to initiate the Power Good
Warning.
Note: To retrieve status information, Status Monitoring in the GUI
DPM Configure Devices window should be enabl ed (refer to
Digital Power Manager Data Sheet). The DPM will retrieve
the status information from each POL on a continuous
basis.
8.3.2 Faults
This group includes overcurrent, overtemperature,
undervoltage, and tracking protection settings.
Triggering any protection in this group will turn off the
POL.
8.3.2.1 Overcurrent Protection
Overcurrent protection is active whenever the output
voltage of the POL exceeds the prebias voltage (if
any). When the output current reaches the OC
threshold, the output voltage will start decreasing. As
soon as the output voltage decreases below the
undervoltage protection threshold, the OC fault
signal is generated, the POL turns off and the OC bit
in the register ST is changed to 0. Both high side and
low side switches of the POL are turned off instantly
(fast turn-off).
The temperature compensation is added to keep the
OC threshold approximately constant at
temperatures above room temperatur e. Note that the
temperature compensation can be disabled in the
POL Configure Output window or directly via the I2C
by writing into the CLS register. However, it is
recommended to keep the temperature
compensation enabled.
8.3.2.2 Undervoltage Protection
The undervoltage protection is only active during
steady state operation of the POL to prevent
nuisance tripping. If the output voltage decreases
below the UV threshold and there is no OC fault, the
UV fault signal is generated, the POL turns off, and
the UV bit in the register ST is changed to 0. The
output voltage is ramped down according to
sequencing and tracking sett ings (regular turn-off).
8.3.2.3 Overtemperature Protection
Overtemperature protection is active whenever the
POL is powered up. If temperature of the controller
exceeds 130°C, the OT fault is generated, POL turns
off, and the OT bit in the register ST is changed to 0.
The output voltage is ramped down according to
sequencing and tracking sett ings (regular turn-off).
If non-latching OTP is programmed, the POL will
restart as soon as the temperature of the controller
decreases below the Overtemperature Warning
threshold of 120°C.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 23 of 35
8.3.2.4 Tracking Protection
Tracking protection is active only when the output
voltage is ramping up. The purpose of the protection
is to ensure that the voltage differential between
multiple rails being tracked does not exceed 250mV.
This protection eliminates the need for external
clamping diodes between different voltage rails
which are frequently recommended by ASIC
manufacturers.
When the tracking protection is enabled, the POL
continuously compares actual value of the output
voltage to its programmed value as defined by the
output voltage and its rising slew rate. If absolute
value of the difference exceeds 250mV, the tracking
fault signal is generated, the POL turns off, and the
TR bit in the register ST is changed to 0. Both high
side and low side switches of the POL are turned off
instantly (fast turn-off).
The tracking protection can be disabled, if it
contradicts requirements of a particular system (for
example turning into high capacitive load where
rising slew rate is not important). It can be disabled
in the POL Configure Fault window or directly via the
I2C bus by writi ng i nto the PC1 register.
Figure 40. Protection Enable Conditions
8.3.3 Errors
The group includes overvoltage protection and the
phase voltage error. The phase voltage error is not
available in ZY7007.
8.3.3.1 Overvoltage Protection
The overvoltage protection is active whenever the
output voltage of the POL exceeds the pre-bias
voltage (if any). If the output voltage exceeds the
overvoltage protection threshold, the overvoltage
error signal is generated, the POL turns off, and the
OV bit in the register ST is changed to 0. The high
side switch is turned off instantly, and simultaneously
the low side switch is turned on to ensure reliable
protection of sensitive loads. The low side switch
provides low impedance path to quickly dissipate
energy stored in the output filter and achieve
effective volt age li m i tation.
The OV threshold can be pr ogrammed from 110% to
130% of the output voltage setpoint, but not lower
than 1.0V.
8.3.4 Faults and Errors Propagation
The feature adds flexibility to the fault management
scheme by giving users control over propagation of
fault signals within and outside of the system. The
propagation means that a fault in one POL can be
programmed to turn off other POLs and devices in
the system, even if they are not directly affected by
the fault.
8.3.4.1 Grouping of POLs
Z-Series POLs can be arranged in several groups to
simplify fault management. A group of POLs is
defined as a number of POLs with interconnected
OK pins. A group can include from 1 to 32 POLs. If
OVP Threshold
Output Voltage
Time
Vo
1.0V
Enable command
0
1
OCP enabled
0
1
prebiased output
OTP
continuously enabled
OVP Threshold
OVP Threshold
UVP Threshold
UVP Threshold
UVP Threshold
PG Low Threshold
PG Low Threshold
PG Low Threshold
PG High=110%VOUT
PG High=110%VOUT
PG High=110%VOUT
Output Voltage
Output Voltage
Power Good
Signal
1
0
Tracking
Thresholds
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 24 of 35
fault propagation within a group is desired, the
propagation bit needs to be checked in the DPM
Configure Faults window. The parameters can also
be programmed directly via the I2C bus by writing
into the PC3 registe r shown in Figure 41.
When propagation is enabled, the faulty POL pulls its
OK pin low. A low OK line initiates turn-off of other
POLs in the group.
Figure 41. Protection Configuration Register PC3
In addition, the OK lines can be connected to the
DPM to facilitate propagation of faults and errors
between groups. One DPM can control up to 4
independent groups. To enable fault propagation
between groups, the respective bit needs to be
checked in the DPM Configure Fault s window, Group
Fault Propagation sub window shown in Figure 42.
Figure 42. DPM Configure Faults Window
In this case low OK line will signal DPM to pull other
OK lines low to initiate shutdown of other POLs as
programmed in the Group Fault Propagation window.
If an error is propagated, the DPM can also generate
commands to turn off a front end (a DC-DC
converter generating the intermediate bus voltage)
and trigger an optional crowbar protection to
accelerate rem oval of the IBV voltage.
8.3.4.2 Propagation Process
Propagation of a fault (OCP, UVP, OTP, and TRP)
initiates regular turn-off of other POLs. The faulty
POL in this case performs either the regular or the
fast turn-off depending on a specific fault as
described in section 8.3.2.
Propagation of an error initiates fast turn-off of other
POLs. The faulty POL performs the fast turn-off and
turns on its low side switch.
Example of the fault propagation is shown in Figure
43 - Figure 44. In this three-output system (refer to
the block diagram in Figure 23), the POL powering
the output V3 (Ch 1 in the picture) encounters the
undervoltage fault after the turn-on. When the fault
propagation is not enabled, the POL turns off and
generates the UV fault signal. Because the UV fault
triggers the regular turn off, the POL meets its turn-
off delay and falling slew rate settings during the
turn-ff process as shown in Figure 43. Since the UV
fault is programmed to be non-latching, the POL will
attempt to restart every 130ms, repeating the
process described above until the condition causing
the undervoltage is removed.
PTM
PGM
TRP
OTP
UVP
OVP
PVP
Bit 7
Bit 0
R
=
Readable bit
W
=
Writable bit
U
=
Unimplemented bit,
read as ‘0’
-
n
=
Value at POR reset
R/W-0
R/W-0
R/W-1
R/W-1
R/W-1
R/W-1
R/W-1
R/W-1
Bit 7
PTM
: Temperature warning Message
1 = enabled
0 = disabled
Bit 6
PGM
: Power good message
1 = enabled
0 = disabled
Bit 5
TRP
: Tracking fault propagation
1 = enabled
0 = disabled
Bit 4
OTP
: Overtemperature fault propagation
1 = enabled
0 = disabled
Bit 3
OCP
: Overcurrent fault propagation
1 = enabled
0 = disabled
Bit 2
UVP
: Undervoltage fault propagation
1 = enabled
0 = disabled
Bit 1
OVP
: Overvoltage error propagation
1 = enabled
0 = disabled
Bit 0
PVP
: Phase voltage error propagation
1 = enabled
0 = disabled
OCP
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 25 of 35
If the fault propagation between groups is enabled,
the POL powering the output V3 pu lls its OK line low
and the DPM propagates the signal to the POL
powering the output V1 that belongs to other group.
The POL powering the output V1 (Ch3 in the picture)
executes the regular turn-off. Since both V1 and V3
have the same delay and slew rate settings they will
continue to turn off and on synchronously every
130ms as shown in Figure 44 until the condition
causing the undervoltage is removed. The POL
powering the output V2 continues to ramp up until it
reaches its steady st ate level.
130ms is the interval from the instant of time when
the output voltage ramps down to zero until the
output voltage starts to ramp up again. Therefore,
the 130ms hiccup interval is guaranteed regardless
of the turn-off delay setting.
Figure 43. Turn-On into UVP on V3. The UV Fault Is
Programmed To Be Non-Latching. Ch1 – V3 (Group
C), Ch2 – V2, Ch3 – V1 (Group A)
Figure 44. Turn-On into UVP on V3. The UV Fault Is
Programmed To Be Non-Latching and Propagate
From Group C to Group A. Ch1 – V3 (Group C),
Ch2 – V2, Ch3 – V1 (Group A)
Summary of protection support, their par ameters and
features are show n i n Table 3
Table 3. Summary of Protection Parameters and Features
Code Name Type When Active Turn
Off Low Side
Switch Propagation Disable
PT
Pretemperature
Warning
Warning
Whenever V
IN
is applied
No
N/A
Readable by
DPM
No
PG Power Good Warning During steady st ate No N/A Readable DPM No
TR
Tracking
Fault
During ramp up
Fast
Off
Regular turn off
Yes
OT
Overtemperature
Fault
Whenever VIN is applied
Regular
Off
Regular turn off
No
OC
Overcurrent
Fault
When VOUT exceeds prebias
Fast
Off
Regular turn off
No
UV
Undervoltage
Fault
During steady state
Regular
Off
Regular turn off
No
OV
Overvoltage
Error
When VOUT exceeds prebias
Fast
On
Fast turn off
No
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 26 of 35
8.4 PWM Parameters
Z-Series POLs utilize the digital PWM controller. The
controller enables users to program most of the
PWM performance parameters, such as switching
frequency, interleave, duty cycle, and feedback loop
compensation.
8.4.1 Switching Frequency
The switching frequency can be programmed in the
POL Controller Configure Compensation window
shown in Figure 45 or directly via the I2C bus by
writing into the INT register shown in Figure 46. Note
that the content of the register can be changed only
when the POL is turne d off.
Switching for all POLs connected to the SD line are
synchronized to the master clock generated by the
DPM. Each POL is equipped with a PLL and a
frequency divider so they can operate at multiples
(including fractional) of the master clock frequency
as programmed by a user. The converters can
operate at 500 kHz, 750 kHz, and 1 MHz. Although
synchronized, switching frequencies of different
POLs are independent of each other. It is
permissible to mix POLs operating at different
frequencies in one system. This allows optimizing
efficiency and transient response of each POL in the
system individually. (Note: POLs assigned to the
same power output bus are forced to use the same
switching frequency)
Figure 45. PWM Controller Window
Figure 46. Interleave Configuration Register INT
8.4.2 Interleave
Interleave is defined as a phase delay between the
synchronizing slope of the master clock on the SD
pin and PWM signal of a POL. The interleave can be
programmed in the POL Controller Configure
Compensation window or directly via the I2C bus by
writing into the INT register.
Every POL generates switching noise. If no
interleave is programmed, all POLs in the system
switch simultaneously and noise reflected to the
input source from all POLs is added together as
shown in Figure 47.
Figure 47. Input Voltage Noise, No Interleave
FRQ2
FRQ1
FRQ0
INT4
INT2
INT1
INT0
Bit 7
Bit 0
R
=
Readable bit
W
=
Writable bit
U
=
Unimplemented bit,
read as ‘0’
-
n
=
Value at POR reset
R/W-0
R/W-0
R/W-0
R/W-0
1)
R/W-0
1)
R/W-0
1)
R/W-0
1)
R/W-0
1)
Bit 7:5
FRQ[2:0]
: PWM Frequency Selection
000: 500kHz
001: 750kHz
010: 1000lHz
011: 1250kHz
100: 1250kHz
101: 1500kHz
110: 1750kHz
111: 2000kHz
Bit 4:0
INT[4:0]
: Interleave position
00h: Ton starts with 0.0° Phase lag to SD Line
01h: Ton starts wi
th 11.25° Phase lag to SD Line
02h: Ton starts with 22.50° Phase lag to SD Line
1Fh: Ton starts with 348.75° Phase lag to SD Line
1)
Initial value depends on the state of the Interleave Mode (
IM
) Input:
IM=Open:
At POR reset the
5 corresponding ADDRESS bits are loaded
IM=Low:
At POR reset a 0 is loaded
INT3
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 27 of 35
Figure 48 shows the input voltage noise of the three-
output system with programmed interleave. Instead
of all three POLs switching at the same time as in
the previous example, the POLs V1, V2, and V3
switch at 67.5°, 180°, and 303.75°, respectively.
Noise is spread evenly across the switching cycle
resulting in more than 1.5 times reduction. To
achieve similar nois e reduction without the interleave
will require the addition of an external LC filt er.
Figure 48. Input Voltage Noise with Interleave
Similar noise reduction can be achieved on the
output of POLs connected in parallel. Figure 49 and
Figure 50 show the output noise of two ZY7007s
connected in parallel without and with 180°
interleave, respectively. Resulting noise reduction is
more than 2 times and is equivalent to doubling
switching frequency or adding extra capacitance on
the output of the POLs.
Figure 49. Output Voltage Noise, Full Load, No Interleave
Figure 50. Output Voltage Noise, Full Load, 180° Interleave
The ZY7007 interleave feature is similar to that of
multiphase conver ters, however, unlike in the cas e of
multiphase converters, interleave does not have to
be equal to 360/N, where N is the number of POLs in
a system. ZY7007 interleave is independent of the
number of POLs in a system and is fully
programmable in 11.25° steps. It allows maximum
output noise reduction by intelligently spreading
switching energy.
Note: Due to noise sensitivity issues that may occur in limited
cases, it is recommended to avoid phase lag settings of
112.5 and 123.75 degrees, otherwise false PG and/or OV
indications may occur. The GUI prohibits such settings.
8.4.3 Duty Cycle Limit
The ZY7007 is a step-down converter therefore VOUT
is always less than VIN. The relationship between the
two parameters is characterized by the duty cycle
and can be estimated from the following equation:
MININ
OUT
V
V
DC
.
=
,
Where, DC is the duty cycle, VOUT is the required
maximum output voltage (including margining),
VIN.MIN is the minimum input volt age.
It is good practice to limit the maximum duty c ycle of
the controller's PWM to a somewhat higher value
compared to the steady-state duty cycle as
expressed by the above equation. This will further
protect the output from excessive voltages. The duty
cycle limit can be programmed in the POL Controller
Configure Compensation window or directly via the
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 28 of 35
I2C bus by writing into the DCL register shown in
Figure 51.
DCL5
DCL4
DCL3
DCL2
DCL0
HI
LO
Bit 7
Bit 0
R = Readable bit
W = Writable bit
U = Unimplemented bit,
read as ‘0’
- n = Value at POR reset
R/W-1
R/W-1
R/W-1
R/W-0
R/W-0
R/W-0
R/W-0
R/W-1
Bit 7:2 DCL[5:0], Duty Cycle Limitation
00h: 0
01h: 1/64
3Fh: 63/64
Bit 1: HI, ADC high saturation feed-forward
0: disabled
1: enabled
Bit 0: LO, ADC low saturation feed-forward
0: disabled
1: enabled
DCL1
Figure 51. Dut y Cycle Limit Register
8.4.4 ADC Saturation Feedforward
To speed up the PWM response in case of heavy
dynamic loads, the duty cycle can be forced either to
0 or the duty cycle limit depending on the polarity of
the transient. This function is equivalent to having
two comparators defining a window around the
output voltage setpoint. When an error signal is
inside the window, it will produce gradual duty cycle
change proportional to the error signal. If the error
signal goes outside the window (usually due to large
output current steps), the duty cycle will change to its
limit in one switching cycle. In most cases this will
significantly improve transient response of the
controller, reducing amount of required external
capacitance.
Under certain circumstances, usually when the
maximum duty cycle limit significantly exceeds its
nominal value, the ADC saturation can lead to the
overcompensation of the output error. The
phenomenon manifests itself as low frequency
oscillations on the output of the POL. It can usually
be reduced or eliminated by disabling the ADC
saturation or limiting the maximum duty cycle to 120-
140% of the calculated value. It is not recommended
to use ADC saturation for output voltages higher
than 2.0V.
The ADC saturation feedforward can be
programmed in the POL Configure Controller
Compensation window or directly via the I2C bus by
writing into the DCL register.
8.4.5 Feedback Loop Compensation
Feedback loop compensation can be programmed in
the POL Controller Configure Compensation window
by setting frequency of poles and zeros of the
transfer functi on.
The transfer function of the POL converter is shown
in Figure 52. It is a third order function with two zeros
and three poles. Pole 1 is the integrator pole, Pole 2
is used in conjunction with Zero 1 and Zero 2 to
adjust the phase lead and limit the gain increase in
mid band. Pole 3 is used as a high frequency low-
pass filter to limit PWM noise.
Z1 P1 Z2 P2 P3
0.1 110 100 1000
Freq
[kHz]
Magnitude[dB]
10
20
30
40
50
0.1 110 100 1000
Freq
[kHz]
-90
-45
-135
-180
0
+45
Phase
[°]
P1: Pole 1
P2: Pole 3
P3: Pole 3
Z1: Zero 1
Z2: Zero 2
Figure 52. Transfer Function of PWM
Positions of poles and zeroes are determined by
coefficients of the digital filter. The filter is
characterized by four numerator coefficients (C0, C1,
C2, C3) and three denominator coefficients (B1, B2,
B3). The coefficients are automatically calculated
when desired frequency of poles and zeros is
entered in the GUI POL Controller Configuration
Compensation window. The coefficients are stored in
the C0H, C0L, C1H, C1L, C2H, C2L, C3H, C3L, B1,
B2, and B3 registers.
Note: The GUI automatically transforms zero and pole
frequencies into the digital filter coeffic ients. Using the GUI
to determine filter coefficients is strongly recommended .
Programming feedback loop compensation allows
optimizing POL performance for various application
conditions. For example, increase in bandwidth can
significantly improve dynamic response.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 29 of 35
8.5 Current Share
The POL converters are equipped with the digital
current share function. To activate the current share,
interconnect the CS pins of the POLs connected in
parallel. The digital signal transmitted over the CS
line sets output currents of all POLs to the same
level.
When POLs are connected in parallel, they must be
included in the same parallel bus in the DPM
Configure Devices window shown in Figure 53. In
this case, the GUI automatically copies parameters
of one POL onto all POLs connected to the parallel
bus. It makes it impossible to configure different
performance parameters for POLs connected in
parallel except for interleave and load regulation
settings that are independent. The interleave allows
to reduce and move the output noise of the
converters connected in parallel to higher
frequencies as shown in Figure 49 and Figure 50.
The load regulation allows controlling the current
share loop gain in case of small signal oscillations. It
is recommended to always add a small amount of
load regulation to one of the converters connected in
parallel to reduce loop gain and therefore improve
stability.
8.6 Performance Parameters Moni toring
The POL converters can monitor their own
performance parameters such as output voltage,
output current, and temperature.
The output voltage is measured at the output sense
pins, output current is measured using the ESR of
the output inductor and temperature is measured by
the thermal sensor built into the controller IC. Output
current readings are adjusted based on temperature
readings to compensate for the change of ESR of
the inductor with tempe rat ure.
An 8-Bit Analog to Digital Converter (ADC) converts
the output voltage, output current, and temperature
into a digital signal to be transmitted via the serial
interface. The ADC allows a minimum sampling
frequency of 1 kHz for all three values.
Monitored parameters are stored in registers (VOM,
IOM, and TMON) that are continuously updated and
not double buffered. If the Group Monitoring
Retrieval enable bits for Parametric (P-Monitor) and
Status (S-Monitor) in the DPM Configure Devices
window shown in Figure 53 are checked, those
registers are copied into the ring buffer located in the
DPM. Contents of the ring buffer can be displayed in
the DPM Monitor Window shown in Figure 54 or it
can be read directly via the I2C bus using high and
low level commands as described in the ”ZM7300
Digital Power Manager Programming M anual”.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 30 of 35
Figure 53 DPM Configure Devices Window
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 31 of 35
Figure 54. DPM Monitoring Window
9. Safety
The ZY7007 POL converters do not provide
isolation from input to output. The input devices
powering ZY7007 must provide relevant isolation
requirements according to all IEC60950 based
standards. Nevertheless, if the system using the
converter needs to receive safety agency approval,
certain rules must be followed in the design of the
system. In particular, all of the creepage and
clearance requirements of the end-use safety
requirements must be observed. These requirements
are included in UL60950 - CSA60950-00 and
EN60950, although specific applications may have
other or additional requirements.
The ZY7007 POL converters have no internal fuse. If
required, the external fuse needs to be provided to
protect the converter from catastrophic failure. Refer
to the “Input Fuse Selection for DC/DC converters”
application note on www.power-one.com
for proper
selection of the input fuse. Both input traces and the
chassis ground trace (if applicable) must be capable
of conducting a current of 1.5 times the value of the
fuse without opening. The fuse must not be placed in
the grounded i nput line.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 32 of 35
Abnormal and component failure tests were
conducted with the POL input protected by a fast-
acting 65 V, 15 A, fuse. If a fuse rated greater than
15 A is used, additional testing may be required.
In order for the output of the ZY7007 POL converter
to be considered as SELV (Safety Extra Low
Voltage), according to all IEC60950 based
standards, the input to the POL needs to be supplied
by an isolated secondary source providing a SELV
also.
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 33 of 35
10. Mechanical Drawings
All Dimensions are in mm
Tolerances:
0.5-10 ±0.1
10-100 ±0.2
Pin Coplanarity: 0.1 max
22.2 ±0.30
36
19
Pin 1
18
5.2
17.7
SMT PICKUP POINT
12.5 ±0.30
2.6
1
0.4
Figure 55. Top (Left) and Bottom Views
12
6.5±0.30
8.7
2.1
Figure 56. Side View
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 34 of 35
44±0.20
40.4±0.10
7.0
1.5
4
Section
Y , Y
Section
X , X
22.8±0.10 (Bo)
1.1 0.3
24
12.8
12.80 (Ao)
Y
Y
X
X
1.00
Pin 1 indicating
Chamfer.
SMT PICKUP
POINT
DIRECTION OF FEED
Figure 57. Tape and Reel
22.20
10.40
1.00
12.50
2.60
Pin 1
0.60
2.00
118
19
36
(x 36)
Top View
Figure 58. Recommended PCB Pad Sizes
ZY7007 7A DC-DC Intelligent POL Data Sheet
3V to 14V Input 0.5V to 5.5V Output
ZD-00245 Rev. 2.8, 5-May-2011 www.power-one.com Page 35 of 35
Figure 59. Recommended PCB Layout for Multilayer PCBs
Notes:
1. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
2. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
I2C is a trademark of Philips Corporation.