Disconnect switches Index Di s sw con itc nec he t s 19 - Disconnect switches Non-fusible and fusible disconnect switches...........19.1 - 19.6 Accessories............................................................19.29 - 19.40 General information Versatility, broad range, compact size................................................................................19.1 International acceptance, installation options, broad range of accessories........................19.2 Mounting, mounting positions, incoming power feeds, terminal connections.....................19.3 Finger proof, door interlock, padlockable, positive opening operation................................19.4 Welded contact protection, clear position indication, visible blades, constant control........19.5 High performance, superior short circuit protection, fuse isolation.....................................19.6 Standard handles & shafts...........................................................................................19.30 - 19.32 Auxiliary contacts.....................................................................................................................19.33 Terminal lugs...........................................................................................................................19.34 Terminal shrouds.....................................................................................................................19.35 Additional poles.......................................................................................................................19.36 Fuse monitors & carriers..........................................................................................................19.37 Miscellaneous accessories & replacement parts......................................................................19.38 Conversion, transfer & bypass mechanisms............................................................................19.39 Non-fusible disconnect switches............................19.7 - 19.18 Approvals and ratings................................................................................................................19.7 Ordering details guide......................................................................................................19.8 - 19.9 Ordering details information.....................................................................................................19.10 Base and DIN rail mounted, 16 - 3150A..................................................................................19.11 Door mounted, 16 - 100A.......................................................................................................19.12 Side operated..........................................................................................................................19.13 Flange & double throw.................................................................................................19.14 - 19.17 OTDC Disconnect switches.....................................................................................................19.18 Enclosed disconnect switches..............................19.41 - 19.48 General information.....................................................................................................19.42 - 19.44 Non-fusible 3 pole, 16A - 3150A...........................................................................................................19.45 6 pole, 16A - 1200A...........................................................................................................19.46 Fusible 3 pole, 30A - 800A.............................................................................................................19.47 Accessories.............................................................................................................................19.48 Fusible disconnect switches.................................19.19 - 19.28 Technical data.........................................................19.49 - 19.66 Approvals and ratings..............................................................................................................19.19 Ordering details guide..............................................................................................................19.20 Ordering details information.....................................................................................................19.21 Base & DIN rail mounted.........................................................................................................19.22 Side operated and flange.............................................................................................19.23 - 19.26 High speed fuse pattern..............................................................................................19.27 - 19.28 Technical data.............................................................................................................19.49 - 19.59 Auxiliary contact timing diagrams.................................................................................19.60 - 19.63 NEMA Environmental ratings.......................................................................................19.64 - 19.65 Definitions................................................................................................................................19.66 Approximate dimensions.......................................19.67 - 19.91 19 19.A Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he sc Di witc s Notes 19 19.B 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Non-fusible & fusible Disconnect switches Non-fusible & fusible disconnect switches General information Versatility ABB disconnect switches are designed to offer maximum versatility in many ways. Broad range ABB's open style non-fusible switches have seventeen amperage sizes from 16A - 3150A. The fusible range is 30A - 1200A. All sizes are compact, heavy duty, 600V disconnect switches. Many sizes are available in 2, 3, 4, 6, and 8 pole configurations. Compact size The non-fusible disconnect switches' compact dimensions allow panel size reduction in new applications or easily retrofit into space-sensitive existing installations. The fusible switch occupies little more panel space than the appropriate fuses. 19 19.1 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con itc nec he t s Revised January 2014 1SXU000023C0202 Rev. A t ec n on es sc h Di witc s General information International acceptance UL listed, CSA approved, IEC rated, CE marked, and most other international standards. UL98 (CSA 22.2 No.4) -- UL File # E101914, CSA File #LR58077 For OT30 - OT1200, OS30A - 1200A switches with OT/OS OH_pistol grip handles Suitable for use as motor disconnects or industrial control panel disconnects on service entrance equipment, panelboards, switchboards, industrial control equipment, motor control centers, etc. and are horsepower and ampere rated. UL508 (CSA 22.2 No. 14) -- UL File # E63822, CSA File #LR58247 For OT16 - OT80 switches, OH_ selector handles Suitable for use in equipment or machinery as motor controllers & motor disconnects and are horsepower and ampere rated. IEC Tested in accordance to IEC 947-1 and 3, IEC 664, IEC 269, and IEC 204. CE Compliance with the European Machine Directive IEC 204 (EN 60204). Installation options Rotary through the door: available in all sizes, non-fusible 16A - 3150A; fusible 30A 1200A. Flange: versions available in 30A - 1200A sizes. A rotary disconnect switch may be installed nearly anywhere in a control panel -- mounting is not limited to the upper right hand corner of the panel. Mount the switch where it conveniently fits in your panel and simply install the handle on the door, in line with the switch. The switch and handle are mechanically linked through an easily adjusted shaft. This allows fast and easy installation into panels of different depths and layouts. 19 Broad range of accessories * Handles -- UL/NEMA type 1, 3R, 4, 4X, 12; IP54, 65, 66 * Auxiliary contacts available for every switch size * Additional power poles * Additional terminal poles (neutrals & grounds) * Terminal shrouds * 6 & 8 pole mechanisms * Transfer mechanisms * Bypass mechanisms * Mechanical interlock mechanisms * Electro-mechanical interlock mechanisms 19.2 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage General information Di s sw con itc nec he t s Mounting Disconnect switches offer several mounting possibilities: * Door mounting on an enclosure door or sidewall for non-fusible, 16A - 100A * DIN rail mounting for non-fusible, 16A - 100A; and fusible, OS30 - OS100 * Base mounting with screws for all switch sizes Mounting positions Disconnect switches offer several mounting possibilities: Incoming power feeds Disconnect switches can be used equally well with either top or bottom incoming power feeds. Terminal connections 19 Versatile connecting possibilities for non-fusible and fusible switches * Ring tongue crimp on lugs * Direct bus * Terminal lugs 19.3 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A t ec n on es sc h Di witc s General information Finger proof Dead-front construction plus terminal shrouds reduce the risk of touching live parts, improving the safety and reliability of the installation. Door interlock The handle and shaft provide a door interlock; the door can not be opened when the switch is in the "ON" position. NOTE: Some handles provide a method for qualified personnel to circumvent the door interlock. This is commonly referred to as a "defeater" mechanism. Padlockable Handles can be padlocked in the "OFF" position with up to three padlocks. Additionally, the switch mechanism can be directly padlocked in the "OFF" position when the door is open. NOTE: Some handles can be ordered with the ability to padlock in both the "ON" & "OFF" positions, please consult your ABB sales office. Positive opening operation All switches operate according to the "positive opening operation" principle. This means the contacts are opened and closed by a driven mechanism, a solid moving bridge, not merely springs. This provides reliable position indication to the user; if the switch is in the "OFF" position, the contacts are open. 19 19.4 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage General information Di s sw con itc nec he t s Welded contact protection Positive opening operation safeguards users in case of welded contacts due to an overload or short circuit. The switch can not reach the "OFF" position unless the contacts are truly open. If any or all of the contacts are welded shut, the switch mechanism will only allow the handle to operate a maximum of 45. This safeguards personnel by: * Alerting them a problem has occurred * Maintaining the door interlock and * Not allowing a padlock to be inserted Clear position indication All switches and handles have clear "ON" and "OFF" designations. Whether the door is open or closed, it is possible to simply look at the switch and determine if the switch is "ON" or "OFF". Visible blades Visible blades offer additional safety for non-fusible switches, 100A -- 1200A Track resistant material Excellent track resistant material, CTI > 600V, IEC 112, reduces the risk of flashover between phases in even the most severe circumstances. Constant control for non-fusible disconnect switches The OT16F3 to OT100F3 provide the user with constant control over the power circuit. Whether the enclosure door is open or closed, qualified personnel have the ability to manually operate the switch. This is most meaningful when qualified personnel are working with the enclosure door open: In case of an emergency down-stream, the main three phase power can be disconnected immediately using the black, direct mounted handle. 19 19.5 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A t ec n on es sc h Di witc s General information High performance The mechanism is quick-make/quick-break, meaning the contacts operate independently of the speed and force at which the handle is operated. This, in combination with unique, patented self-cleaning contacts, provides a long, reliable, electrical life. Superior short circuit protection Fuses efficiently limit the peak let-through current, i2t, during a fault better than any other product, contributing to safety and reliability. Selectivity and coordination are easily accomplished with fused protection. Fusible disconnect switches accept a wide range of fuses: Class CC 30A Class J 30A - 600A Class L 800A - 1200A Fuse isolation Fused switches contain contacts on both sides of the fuse. The fuses are totally isolated in the "OFF" position, reducing the risk of shock to authorized personnel -- even if the switch has been back fed. 19 19.6 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Non-fusible Disconnect switches Non-fusible disconnect 16A - 3150A, 600VAC 100-200A, 1000VDC ABB SwitchLine includes 16 different amperage sizes from 16A to 3150A. The basic construction provides flexibility, safety, and high performance in an extremely compact size. ABB SwitchLine is a perfect choice for all switching applications from industrial motor control to construction safety switches. International acceptance UL listed, CSA approved, IEC rated, CE marked, and most other international standards. UL98 (CSA 22.2 No.4) -- UL File # E101914, CSA File #LR58077 For OT30, OT60, OT100, OT200, OT400, OT600, OT800, OT1200 OETL-NF1600 - OETL-NF2000 switches, OH_ pistol grip handles Suitable for use as motor disconnects or industrial control panel disconnects on service entrance equipment, panelboards, switchboards, industrial control equipment, motor control centers, etc. and are horsepower rated and ampere rated. UL508 (CSA 22.2 No. 14) -- UL File # E63822, CSA File #LR58247 For OT16 - OT80 switches, OH_ selector handles Suitable for use in equipment or machinery as motor controllers & motor disconnects and are horsepower and ampere rated. IEC Tested in accordance to IEC 947-1 and 3, IEC 664, IEC 269, and IEC 204 CE Compliance with the European Machine Directive IEC 204 (EN 60204) 19.7 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con switchesNo itc nec n- he t fus s ibl e Revised January 2014 1SXU000023C0202 Rev. A 19 ct ne s n o e sc h le Di witc usib s n-f No General information Selection guide OT16F3 - OT100F3 OT16F3 OT25F3 OT40F3 Catalog number 3 pole OT16F3 OT25F3 OT80F3 OT30F3 OT60F3 OT40F3 OT63F3 OT80F3 OT30F3 OT100F3 OT60F3 OT100F3 20 30 40 60 80 30 60 100 N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC 600 600 600 600 600 600 600 600 5 10 10 7.5 15 20 10 20 25 15 30 30 20 40 40 10 20 30 20 40 40 30 50 50 1 2 1.5 3 2 5 2 5 2 5 2 5 3 7.5 5 15 Technical ratings - IEC2 Rated insulation and operational voltage. AC20 and DC20 V 750 750 750 750 750 750 750 750 Rated thermal current, Ith AC 20/DC 20 open AC 20/DC 20 enclosed A A 25 25 32 32 40 40 63 63 80 80 40 40 63 63 115 115 AC 21A 500V 690V A A 16 16 25 25 32 32 63 63 80 80 40 40 63 63 100 100 Rated operational power AC23 400/415V kW 690V kW 7.5 7.5 9 9 11 11 22 15 37 18.5 15 15 18.5 15 37 37 General purpose amp rating A OT63F3 Approvals 1 2 pole 3 pole 4 pole Technical ratings - UL,CSA 2 Max operating voltage V Max horsepower rating Three phase 240V HP 480V HP 600V HP Single phase 120V 240V HP HP Physical characteristics lb 0.24 0.24 0.24 0.59 0.59 0.79 0.79 0.79 Dimension 3 pole H in W in D in Weight 3 3 pole 2.68 1.38 2.20 2.68 1.38 2.20 2.68 1.38 2.20 3.60 2.07 2.85 3.60 2.07 2.85 3.94 2.76 2.95 3.94 2.76 2.95 3.94 2.76 2.95 Integral Integral Integral Integral Integral Integral Integral * * * * * * * * * * * * * * Accessories Terminal lug kit Integral * Auxiliary contact * Shaft/handle diameter 6mm Terminal shroud 19 .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" 6mm .24" x .24" Handle UL/NEMA type Type 1, 3R, 12 Type 1, 3R, 4, 4X, 12 * * * * * * * * * * * * * * * * * * * * * * * * -- -- -- Handle type Selector * Pistol * * * * Recommended pistol handle length Maximum recommended shaft length 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm Conversion kits 6 pole Transfer Bypass Mechanical interlock * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * -- -- -- -- -- -- -- Electrical interlock -- * = Available -- = Not available 1 UL listed switches are also CSA approved. 2 For complete technical information please see page 19.49-19.66. 3 Switch only. 19.8 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage General information Selection guide OT200 - OT1200 & OETL-NF1600 - OETL-NF3150 OT200U03 Catalog number OT400U03 3 pole OT600U03 OT200U03 OT1200U03 OETL-NF1600SW OETL-NF2000SW OETL-NF3150SW OT400U03 OT600U03 OT800U03 OT1200U03 OETL-NF1600 OETL-NF2000 200 400 600 800 1200 1600 2000 3150 UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC IEC IEC IEC A General purpose amp rating OT800U03 Di s sw con No itc nec n- he t fus s ibl e OETL-NF3150 Approvals 1 2 pole 3 pole 4 pole Technical ratings - UL,CSA 2 Max operating voltage V 600 600 600 600 600 600 480 600 Max horsepower rating Three phase 240V 480V 600V HP HP HP 75 150 200 125 250 350 200 450 500 250 500 600 -- -- -- -- -- -- -- -- -- -- -- -- Single phase 120V 240V HP HP -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Technical ratings - IEC 2 Rated insulation and operational voltage. AC20 and DC20 V 1000 1000 1000 1000 1000 1000 1000 1000 Rated thermal current, Ith AC 20/DC 20 open AC 20/DC 20 enclosed A A 250 250 400 400 800 800 1250 1250 1600 1600 2500 2300 2500 2300 3150 2600 AC 21A 500V 690V A A 250 250 400 400 800 800 1250 1250 1600 1600 25004 25004 25004 25004 31504 31504 Rated operational power AC23 400/415V kW 690V kW 132 240 220 355 400 800 400 -- 400 -- 400 -- 400 -- 400 -- Physical characteristics Weight 3 3 pole Dimension 3 pole H W D lb 2.9 5.7 11.4 35.9 38.55 127.7 127.7 127.7 in in in 6.69 6.67 3.30 8.66 8.7 3.35 10 10.64 5.56 19.09 14.29 4.92 19.09 14.29 4.92 25.04 18.43 10.67 25.04 18.43 10.67 25.04 18.43 10.67 OZXA-200 OZXA-400 OZXA-800 OZXA-1200 OZXA-1200 OZXA-28 OZXA-28/2 OZXA-28/2 * * * * * * * * -- -- -- * * * Accessories Terminal lug kit * Auxiliary contact * Terminal shroud Shaft/handle diameter 6mm .24" x .24" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" 12mm .47" x .47" Handle UL/NEMA type Type 1, 3R, 12 Type 1, 3R, 4, 4X, 12 * * * * * * * * * * * * * * * * -- -- -- -- -- -- -- 65 - 80mm 290mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm * * * * * * * * * * * * * * * * * * * * * * * * * -- -- -- -- -- -- -- -- -- Handle type Selector -- Pistol * Recommended pistol handle length Maximum recommended shaft length Conversion kits 6 pole Transfer Bypass Mechanical interlock Electrical interlock * * * * * * * * * * 19 * * * S = Standard feature * = Available -- = Not available 1 2 3 4 UL listed switches are also CSA approved. For complete technical information please see page 19.49-19.66. Switch only IEC 947-3 Utilization Category B, Infrequent operation 19.9 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h le Di witc usib s n-f No Selection information Standard part number designation 1 Non-Fusible OT Switches (16 to 100A) OT 16 F 3 C Amperage 16 = 20 amps* 25 = 30 amps* 40 = 40 amps* Number of Poles 3 = 3 poles 63 = 60 amps* 80 = 80 amps* 30 = 30 amps 60 = 60 amps 100 = 100 amps 160 = 125 amps 4 = 4 poles 6 = 6 poles Special Configuration C = Double throw switch * UL508 listed switches. OT30_, OT60_ and OT100_ are cUL98 listed Non-Fusible OT Switches (200A and above) OT 200 U 03 C Amperage 200 = 200 amps 400 = 400 amps 600 = 600 amps Number of Poles & Placement of Mechanism 02 = 2 poles to right of mechanism 03 = 3 poles to right of mechanism 30 = 3 poles to left of mechanism 12 = 1 pole to left, 2 poles to right of mechanism 800 = 800 amps 1200 = 1200 amps 04 = 4 poles to right of mechanism 40 = 4 poles to left of mechanism 22 = 2 poles to left, 2 poles to right of mechanism 13 = 1 pole to left, 3 poles to right of mechanism Special Configuration C = Double throw switch All OT200__, OT400_, OT600_ , _OT800_ and OT1200_ switches are cUL98 listed. Selector Handles OHB S 1 P H Handle Color B = black Y = Red/Yellow Physical Size Connection to Switch A = external shaft P = snap on Protection Class H=1 R = screw J= 1, 3R, 12 Pistol Handles O H B 65 J 6 E011 Handle Color B = Black Y = Red/Yellow Handle Length 65 = 65mm 80 = 80mm M = Stainless Steel 125 = 125mm 145 = 145mm 274 = 274mm 330 = 330mm Environmental Rating J = 1, 3R, 12 19 L = 1, 3R, 12, 4, 4X Shaft Diameter 6 = 6mm 12 = 12mm Special Configuration E011 = 3 position double throw handle EH = Stainless steel hasp 1 Part designation keys are provided for reference only. Not all variations or configurations are available. 19.10 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con No itc nec n- he t fus s ibl e Base & DIN rail mounted 1 16A - 3150A For a complete assembly, please select one of each: 1 switch (page 19.11) 1 handle (page 19.30) 1 shaft (page 19.32) 1 terminal lug kit (page 19.34) NOTE: For additional accessories, see pages 19.29 - 19.40. (Lug kits only necessary on switches 200A and above) OT200U03 + OXP6X210 + OHB80J6 + OZXA-200 2 Pole 3 Pole 4 Pole 2 6 Pole 3 Catalog number Catalog number Catalog number Catalog number UL only UL general purpose amp rating IEC AC21 amp rating UL 508 20 30 40 60 80 16 25 40 63 80 -- -- -- -- -- OT16F3 OT25F3 OT40F3 OT63F3 OT80F3 -- -- -- -- -- OT16F6 OT25F6 OT40F6 OT63F6 OT80F6 30 60 100 40 63 115 -- -- -- OT30F3 OT60F3 OT100F3 -- -- -- OT30F6 OT60F6 OT100F6 200 250 OT200U02 OT200U03 OT200U30 OT200U12 OT200U04 OT200U40 OT200U22 -- -- -- 400 630 OT400U02 OT400U03 OT400U30 OT400U12 OT400U04 OT400U40 OT400U22 -- -- -- 600 800 OT600U02 800 1200 1600 2000 - 1250 1600 2500 4 2500 4 3150 4 OT600U03 OT600U30 OT600U12 OT800U03 OT1200U03 OETL-NF1600SW OETL-NF2000SW OETL-NF3150SW OT600U04 OT600U40 OT600U22 OT800U04 OT1200U04 OETL-NF16004SW OETL-NF20004SW OETL-NF31504SW -- -- -- -- -- -- -- -- UL 98 OT800U02 OT1200U02 OETL-NF16002SW OETL-NF20002SW OETL-NF31502SW Bulk packed 3 Pole, 600V Switches 5 UL only UL general purpose amp rating Bulk pack Quantity Catalog number UL508 20 30 40 60 80 IEC AC21 amp rating 16 25 40 63 80 50 50 50 50 50 OT16F3/B50 OT25F3/B50 OT40F3/B50 OT63F3/B50 OT80F3/B50 UL98 30 60 100 40 63 115 25 25 25 OT30F3/B25 OT60F3/B25 OT100F3/B25 19 1 2 3 4 5 Above 100A, base mount with screws only. A snap on fourth pole may be added on 16-100A switches. For a 6 or 8 pole switch 200 amp and above, a conversion mechanism accessory kit can be used with two 3 or 4 pole switches. See page 19.40. Vertical busbar provided as standard on OETL-NF1600-OETL-NF3150 switches. For alternate back or edgewise mounting busbar, see page 19.38. Order quantity is 1. 19.11 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h le Di witc usib s n-f No Door mounted 1 16 - 100A For a complete assembly, please select one of each: 2 1 switch (page 19.12) 1 handle (page 19.30) + NOTE: For additional accessories, see pages 19.29 - 19.40. OHBS2RJ OT63FT3 Bulk packs 3 Pole 3 UL only UL508 UL98 UL general purpose amp rating IEC AC21 amp rating 20 30 40 60 80 30 60 100 16 25 40 63 80 40 63 115 Catalog number OT16FT3 OT25FT3 OT40FT3 OT63FT3 OT80FT3 OT30FT3 OT60FT3 OT100FT3 Bulk pack quantity 50 50 50 50 50 25 25 25 Bulk pack Catalog number OT16FT3/B50 OT25FT3/B50 OT40FT3/B50 OT63FT3/B50 OT80FT3/B50 OT30FT3/B25 OT60FT3/B25 OT100FT3/B25 19 1 2 3 4 Door mounted switches do not provide door interlock Door mounted switches do not require shafts A snap on fourth pole may be added The environmental rating of the pistol handle derates to NEMA 1 when used in conjunction with the OHZX6 adapter. 19.12 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con No itc nec n- he t fus s ibl e Other configurations Side operated 30 - 600A For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit + + OETL-NF400-S OXP12x325 OHB145J12E00S Side operated switches -- 3 pole OSNF30-S UL general purpose amp rating IEC AC21 amp rating Maximum horsepower rating 200V 208V 240V 480V 600V 30 60 100 400 600 32 63 125 630 800 5 15 25 100 150 7.5 15 25 100 150 7.5 15 30 125 200 15 30 60 250 400 20 50 75 350 500 Weight (Lbs.) Three phase 1.90 3.90 4.50 13.66 13.66 Catalog number OSNF30-S 1 OSNF60-S 1 OSNF100-S OETL-NF400-S OETL-NF600A-S Handles UL/NEMA type Color For use with OSNF30-S Black 1, 12, 3R Red/Yel OETL-ZX74 Length inches/mm Marking Defeatable Padlockable Weight (Lbs.) 2.65/65 O/I & Off/On Yes Yes Yes OHB65J6E00S OHY65J6E00S Yes Yes Yes OHB80J6E00S OHY80J6E00S Yes Yes Yes OHB145J12E00S OHY145J12E00S OETL-ZX74 For use with OSNF60-S -- OSNF100-S Black 1, 12, 3R 3.1/80 O/I & Off/On Red/Yel For use with OETL-NF400-S -- OETL-NF600A-S Black O/I & Off/On 1, 12, 3R Red/Yel 4.9/145 O/I & Off/On Metal Off/On OHY__J__ Catalog number Shaft Length (Inches/mm) For use with: OXP6X170 OXP12X325 OSNF30-S OSNF60-S - OSNF100-S OETL-NF400-S - OETL-NF600A-S Description 6.7/170 .20 x .20" (5 x 5mm) 8.3/210 .24 x .24" (6 x 6mm) 12.8/325 .47 X .47" (12 X 12mm) Weight (Lbs.) Catalog number 0.08 0.10 0.90 OXP6X170 OXP6X210 OXP12X325 19 Terminal lug kits For use with: OZXA-24 OZXA-25 OZXA-26 OSNF30-S OSNF60-S OSNF100-S OETL-NF400-S OETL-NF600A-S Wire size Weight Wire type Lugs per kit #18 - 8 #14 - 4 #14 - 2/0 #2 - 600 kcmil (2) #2 - 600 kcmil -- -- 0.43 3.520 4.62 Cu Cu Cu/Al Cu/Al Cu/Al -- -- 6 6 6 Integral Integral OZXA-24 OZXA-26 OZXA-27 1 Fused switches with solid links installed. 19.13 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Catalog number Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h le Di witc usib s n-f No Special configurations Shaft operated flange 30A - 100A + + Switch Handle Shaft 30A -100A Flange operated -- non fusible switches (Shaft) - 3 pole UL general purpose amp rating Catalog number 30 60 100 OT100F3 OT30F3-F OT60F3-F OT100F3-F Flange handles -- for use with OT30_, OT60_, OT100 UL/ NEMA type Marking Defeatable Padlockable Catalog number 1, 3R, 12 4, 4X OFF/ON OFF/ON Yes Yes Yes Yes DSFHN-HS12 DSFHN-HS4 For use with: Maximum enclosure depth (inches) OT30_ - OT100_ OT30_ - OT100_ 16 24 Shafts DSFHN-HS12 Catalog number OTFS-16 OTFS-24 Door hardware NEMA 12 Item Catalog number Safety door latch, 2 point, door less than 40" high KDH2R Safety door latch, 2 point, door greater than 40" high KDH3R Flange operated fusible and non-fusible disconnect switches DSFHS-12 ABB's solution for complying with the new NFPA79 requirements is Flange Operated Fusible and Non-fusible Disconnect Switches. NFPA 79 changes requires main disconnecting means to be operable without the use of accessory tools or devices, independent of door position. This code also includes an interlocking provision to prevent the closing of disconnects while the enclosure door is open, unless an interlock is operated by a deliberate action. The flange operated disconnect switches are available as ridged shaft or flexible cable operated versions. The cable operated version allows you to install the disconnect switch virtually anywhere in the enclosure depending on the length of the cable. Cables are available in lengths up to 84 inches. 19 The designs are cost-effective NFPA 79 solutions offering quick and easy installation. 19.14 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con No itc nec n- he t fus s ibl e Special configurations Cable operated flange 30A - 1200A + Switch + + Handle Cable + Lug kit (as required) Operating mechanism 1 Non-fusible UL general purpose amp rating Catalog number 30 60 100 200 UL general purpose amp rating OT30F3 OT60F3 OT100F3 OT200U30 400 600 800 1200 Catalog number OETL-NF400-FC 2 OETL-NF600A-FC 2 OETL-NF800A-FC 2 OETL-NF1200-FC 2 Flange handles -- UL98; UL file #E101914 OT100F3 For use with: OT30 - 100F3, OT160E3, OT200U30 OETL-NF400_, OETL-NF600_, OETL-NF800_, OETL-NF1200_ Environmental rating NEMA 1, 3R, 12 NEMA 4, 4X NEMA 1, 3R, 12 NEMA 4, 4X Catalog number OHF1C12 OHF1C4 K7FCH K7FCH4 Flexible cables Cable length (inches) OT30 - 100F3, OT160E3, OT200U30 36 48 60 72 84 OXC1L36 OXC1L48 OXC1L60 OXC1L72 OXC1L84 OETL-NF400_, OETL-NF600_, OETL-NF800_, OETL-NF1200_ 48 60 72 84 K7C048 K7C060 K7C072 K7C084 OHF1C12 OXC1L36OXC1L84 Catalog number For use with: Operating mechanisms For use with: OT30 - 100F3 OT160E3 OT200U30 OETL-NF400-FC, OETL-NF800_, OETL-NF1200-FC Catalog number MKCS1 MKCS3 MKCS4 Included 19 1 Operating mechanism required for OT30 - OT200 2 Operating mechanism is included. 19.15 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h le Di witc usib s n-f No Special configurations Cable operated flange 30A - 1200A Terminal lug kits For use with OT200U30 OETL-NF400-FC OETL-NF600 OETL-NF800 OETL-NF1200 Wire size Wire type Description Lugs per kit #4 - 300 kcmil #4 - 300 kcmil (6) #4-6 AWG #2 - 600 kcmil #2 - 600 kcmil #2 - 600 kcmil (6) 14-6 AWG (4) #2-600 kcmil (8) 2/0 + (2) #2-600 kcmil (8) 2/0 + (2) #2-600 kcmil Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al -- -- Distribution lug Distribution lug Distribution lug 6 3 3 6 6 3 3 6 3 3 Catalog number OZXA-200 OZXA-200/3 OZXA-206S OZXA-26 OZXA-27 OZXA-27/3P OZXA-175/400 OZXA-28 OZXA-28/3P OZXA-32 Door hardware -- NEMA 12 Catalog number Item Safety door latch, 2 point, door less than 40" high Safety door latch, 3 point, door greater than 40" high KDH2R KDH3R Terminal shrouds Description Weight (lbs.) OT30 - OT100 3 Pole 0.02 OTS125T3 OT200 3 Pole Long Type Shroud 0.2 OTS250G1L/3 OT200 3 Pole Short Type Shroud 0.13 OTs250G1S/3 OETL-NF400 3 Pole (includes one shroud for line and load side) 0.62 OETL-ZX111 For use on Catalog number OETL-NF600 3 Pole (includes one shroud for line and load side) 0.66 OETL-ZX94 OETL-NF800 3 Pole (includes one shroud for line and load side) 0.88 OETL-2X800A OETL-NF1200 3 Pole (includes one shroud for line and load side) 1.2 OETL-2X119 19 19.16 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con No itc nec n- he t fus s ibl e Special configurations Double throw switches 16A - 600A For a complete assembly, please select one of each: + 1 switch (page 19.17) 1 handle (page 19.30) 1 shaft (page 19.32) 1 terminal lug kit (page 19.34) 1 bridging bar (page 19.17) NOTE: For additional accessories, see pages 19.29 - 19.40 + OHY__J6E011 OT200U04C + OXS6X__ + Lug kit (as required) Bridging bars (Lug kits only necessary on switches 200A and above) UL only UL508 OT63F3C UL98 UL general purpose amp rating IEC AC21 amp rating 3 Pole 4 Pole 1 Catalog number Catalog number 20 30 40 60 80 16 25 40 63 80 OT16F3C OT25F3C OT40F3C OT63F3C OT80F3C -- -- -- -- -- 30 60 100 40 63 115 OT30F3C OT60F3C OT100F3C -- -- -- 200 250 OT200U03C OT200U30C OT200U04C OT200U40C 400 630 OT400U03C OT400U30C OT400U04C OT400U40C 600 800 OT600U03C OT600U30C OT600U04C OT600U40C 800 1250 OT800U03C OT800U30C OT800U04C OT800U40C Bridging busbar kits -- required for OT200_C through OT600_C 2 OTZC13 Description For Use On: Catalog number 3 Pole Kit OT200_C OT400_C OT600_C OT800_C OTZC13 OTZC23 OTZC33 OTZC53 4 Pole kit OT200_C OT400_C OT600_C OT800_C OTZC14 OTZC24 OTZC34 OTZC54 Bridging bars are required on 200-600A double throw switches to operate as standard double throw switches. Otherwise, they will operate as two mechanically interlocked switches. 19 1 A snap on power pole may be added to build a 4 pole 16-100A double throw switch. 2 For 16-100A double throw switches, jumpers are not provided. 19.17 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h le Di witc usib s n-f No OTDC Disconnect switches 28A - 55A, 600VDC 100A - 200A, 1000VDC UL General purpose amp rating UL Category IEC DC21B amp rating Number of circuits Number of poles Catalog number w/jumper installed Catalog number w/o jumper 28A - 55A, 600VDC 28 28 1 8 +1 - OT40FD9N2 55 55 1 8 - OT80FD8 100 100 1 2 OTDC100US11 OTDC100U11 100 100 1 2 OTDC100US02 OTDC100U02 100 100 2 4 OTDC100US22 OTDC100U22 200 250 1 2 OTDC200US11 OTDC200U11 200 250 1 2 OTDC200US02 OTDC200U02 180 250 2 4 OTDC180US22 OTDC180U22 250 315 1 2 OTDC250US11 OTDC250U11 250 315 1 2 OTDC250US02 OTDC250U02 250 315 2 4 OTDC250US22 OTDC250U22 320 400 1 2 OTDC320US11 OTDC320U11 320 400 1 2 OTDC320US02 OTDC320U02 320 400 2 3 OTDC320US22 OTDC320U22 400 500 1 2 OTDC400US11 OTDC400U11 400 500 1 2 OTDC400US02 OTDC400U02 400 500 2 2 OTDC400US22 OTDC400U22 Switch size Units type (pcs) Weight/ unit (lbs.) Catalog number 100...200 6 0.04 OTDCB250/6 250...400 6 0.05 OTDCB400/2 UL508 100A - 200A, 1000VDC OTDC200U11 OTDC200U02 UL98B Phase separators Grey plastic plate for maintaining 1" clearance between the phases without terminal shrouds. Snap on mounting. Includes as standard in OTDC100...200U_types. Jumper / heat sink Switch size Units type (pcs) Weight/ unit (lbs.) Catalog number 100...200 1 0.04 OEZXY91 250...400 1 0.08 OEZXY96 Terminal lugs Switch size Catalog number 100...200 OZXA-200 250...400 OZXA-400 Wiring diagrams 2 Pole 19 + 4 Pole 1000 V DC 1000 V DC 1000 V DC + - + - - Factory jumper Jumper OTDC_US11 OTDC200U11 Load Jumper OTDC_US22 OTDC_U22 L o a d + 1000 V DC Load Load L o a d + 1 "S" indicates jumpers installed. Jumpers are installed on line side, connecting 2 poles in series 19.18 1SXU000023C0202 Rev. A 1000 V DC L o a d + 1000 V DC Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Fusible Disconnect switches Fusible disconnect switches 30A - 1200A, 600VAC ABB PowerLine includes seven different amperage sizes from 30A to 1200A. All ABB fusible switches are designed to meet customer requirements in terms of high interrupting capacity and long electrical life while occupying little more panel space than the appropriate fuses. The basic construction provides flexibility and high performance in an extremely compact size. ABB PowerLine switches are a perfect choice to withstand the heat and humidity of the tropics, the extreme cold of the arctic and any rugged industrial environment you may have. International acceptance ABB fusible switches are available with a wide range of fuse clip options: UL USA CSA Canada DIN Europe BS United Kingdom NFC France Ultra-rapid As well as the corresponding approvals: UL listed, CSA approved, IEC rated, CE marked, and most other international standards. UL98 (CSA 22.2 No.4) -- UL File # E101914, CSA File #LR58077 For 30A - 1200A switches, OH__ pistol grip handles Suitable for use as motor disconnects or industrial control panel disconnects on service entrance equipment, panelboards, switchboards, industrial control equipment, motor control centers, etc. and are horsepower rated and ampere rated. IEC Tested in accordance to IEC 947-1 and 3, IEC 664, IEC 269, and IEC 204 CE Compliance with the European Machine Directive IEC 204 (EN 60204) 19.19 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tche ect sib s le Revised January 2014 1SXU000023C0202 Rev. A 19 ct ne s n o e sc h Di witc ible s us F Selection guide OS30FACC12 - OS1200L03 OS30FA_12 OS60GJ03 OS100GJ03 Catalog number 3 pole OS30FACC12 General purpose amp rating 2 pole 3 pole 4 pole OS400J03 OS600J03 OS800L3 OS1200L03 OS30FAJ12 OS60GJ12 OS100GJ03 OS200J03 OS400J03 OS600J03 OS800L3 OS1200L03 30 30 60 100 200 400 600 800 1200 N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC 600 600 600 600 600 600 600 600 600 A Approvals 1 OS200J03 Technical ratings (UL,CSA) Max operating voltage V Max horsepower rating Three phase 240V HP 7.5 7.5 15 30 60 125 200 250 -- 480V HP 15 15 30 60 125 250 400 500 -- 600V HP 20 20 50 75 150 350 500 600 -- Single phase 120V HP 2 2 -- -- -- -- -- -- -- 240V HP 3 3 -- -- -- -- -- -- -- UL fuse class CC Technical ratings (IEC) Rated insulation and operational voltage. AC20 and DC20 V J J J J J J L L 1000 1000 1000 1000 1000 1000 1000 1000 1000 Rated thermal current, Ith AC 20/DC 20 open AC 20/DC 20 enclosed A A 32 32 32 32 63 63 160 160 200 200 400 400 630 600 800 720 1250 1250 AC 21A 500V 690V A A 32 32 32 32 63 63 160 160 200 200 400 400 630 630 800 800 1250 1250 14/15 25 14/15 25 30 60 80/90 132 110 200 220/230 400 355 560 350/380 600 560 1000 lb lb 1.54 1.98 1.54 1.98 2.86 3.52 3.30 3.96 5.9 7.5 12.56 15.21 28.66 37.48 37.44 46.26 63.93 -- Dimension 3 pole H in W in D in 3.66 4.15 4.10 3.60 4.15 4.10 3.94 5.63 5.04 5.67 7.07 5.10 6.5 7.1 5.2 9.29 10.04 6.93 12.03 13.86 9.18 12.03 13.86 9.18 16.7 16.42 11.62 Double break contacts S S S S S S S S S Fuse cover S S S S S S S S S Integral Integral Integral OZXA-24 OZXA-200 OZXA-400 OZXA-800 OZXA-1200 OZXA-1200 Not required Not required Not required * * * * * * * * * * * * * * 6mm .24 x .24" 6mm .24 x .24" 6mm .24 x .24" 6mm .24 x .24" 12mm .47 x .47" 12mm .47 x .47" 12mm .47 x .47" 12mm .47 x .47" * * * * * * * * * * * * * * * * Rated operational power AC23 400/415V 690V kW kW Physical characteristics Weight 3 pole switch 4 pole Accessories Terminal lug kit Terminal shroud Auxiliary contact * 6 19 Shaft/handle diameter .24 x .24" mm Handle UL/NEMA type Type 1, 3R, 12 * Type 1, 3R, 4, 4X, 12 * Recommended pistol handle length Maximum recommended shaft length 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 45 - 65mm 290mm 65 - 80mm 290mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm 125 - 175mm 595mm Electrical interlock -- -- -- -- -- * * * * S = Standard * = Available -- = Not available 1 UL listed switches are also CSA approved. 19.20 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tche ect sib s le Selection information Standard part number designation 1 Fusible OS Switches (30A) OS 30 F A J 22 F Amperage 30 = 30 amps Fuse Type/Class J = Class J fuse compatible CC= Class CC fuse compatible Number of poles and placement of the mechanism 12 = 1 Pole to the left of mechanism, 2 poles to the right of mechanism 22 = 2 Poles to the left of mechanism, 2 poles to the right of mechanism Fusible OS Switches (60 to 100A) OS 100G J 03 Amperage 60 = 60 amps 100 = 100 amps Fuse Type/Class J = Class J fuse compatible Number of poles and placement of the mechanism 03 = 3 Poles to the right of mechanism 04 = 4 poles to the right of mechanism Fusible OS Switches (200A and above) OS 200 J 04 F Amperage 200 = 200 amps 400 = 400 amps 600 = 600 amps 800 = 800 amps 1200 = 1200 amps Fuse Type/Class J = Class J fuse compatible Number of poles and placement of the mechanism 03 = 3 Poles to the right of mechanism 12 = 1 Pole to left of mechanism, 2 poles to right 30 = 3 Poles to the left of mechanism 04 = 4 poles to the right of mechanism 22 = 2 Poles to left of mechanism, 2 poles to right 40 = 4 Poles to the left of mechanism Pistol Handles O H B 65 J 6 E011 Handle Color B = Black Y = Red/Yellow Handle Length 65 = 65mm 80 = 80mm M = Stainless Steel 125 = 125mm 145 = 145m 175 = 175mm 274 = 274mm 275 = 275mm 330 = 330mm Environmental Rating J = 1, 3R, 12 L = 1, 3R, 12, 4, 4X Shaft Diameter 6 = 6mm 12 = 12mm Special Configuration E011 = 3 position transfer switch handle EH = Stainless Steel Hasp 19 1 Part designation keys are provided for reference only. Not all variations or configurations are available. 19.21 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h Di witc ible s us F Base & DIN rail mounted 30 - 1200A For a complete assembly, please select one of each: 1 switch (page 19.22) 1 handle (page 19.30) + 1 shaft (page 19.32) + + 1 terminal lug kit (page 19.34) NOTE: For additional accessories, see pages 19.29 - 19.40. OS400J03 + OXP12X280 + OHB145J12 + OZXA-24 (Only required for 100A & above.) OS30FAJ12 UL 98 UL general purpose amp rating 2 Pole 3 Pole 4 Pole UL Fuse Type 600V Catalog number Catalog number Catalog number 30 J CC 1 -- -- OS30FAJ12 OS30FACC12 OS30FAJ22F OS30FACC22F 60 J -- OS60GJ12 2 OS60GJ03 OS60GJ22F 100 J -- OS100GJ12 2 OS100GJ03 2 OS100GJ04F 200 J OS200J02 OS200J03 OS200J30 OS200J12 OS200J04F OS200J13F OS200J22F 400 J OS400J02 OS400J03 OS400J30 OS400J12 OS400J04F 600 J OS600J02 OS600J03 OS600J30 OS600J12 OS600J04F 800 L OS800L02 OS800L03 OS800L04F 1200 L OS1200L02 OS1200L03 OS1200L04F 19 1 Rejection style fuses only. 2 Din Rail Mountable: 60A & 100A requires Din Rail Adapter OSGZD1 19.22 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tche ect sib s le Other configurations Side operated 30A - 400A, UL fuse class J,CC For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug + + OS30FAJS30 OXP6X170 OHY65L6E00S Side operated switches -- 3 pole OS60GJS30 Maximum horsepower rating UL general purpose amp rating UL fuse type 600V 200V 208V 240V 480V 600V 30 30 60 100 200 400 J CC J J1 J1 J1 5 5 15 25 50 100 7.5 7.5 15 25 50 100 7.5 7.5 15 30 60 125 15 15 30 60 125 250 20 20 50 75 150 350 IEC type Color Length (Inches/mm) Marking Defeatable Padlockable OFF/ON Yes Yes 0.29 OHB65J6E00S OHY65L6E00S OFF/ON Yes Yes 0.30 OHB80J6E00S Yes Yes 0.39 No Yes 1.50 Three phase Weight (Lbs.) 1.54 1.54 3.52 3.97 15.21 17.20 Catalog number OS30FAJS30 OS30FACCS30 OS60GJS30 OS100GJS30 OES200J3-S OES400J3-S Handles UL/NEMA type Weight Catalog number For use with OS30A_S30 Black 2.6/65 Red/Yel For use with OS60GJ30, OS60JS30 & OS100GJ30 Black 1, 3R, 12 IP65 3.1/80 Red/Yel For use with OES200J3-S & OES400J3-S Black Red/Yel 1, 3R, 12 IP65 4.9/145 Metal 1, 3R, 12 OS100GJS30 IP65 OFF/ON OHB145J12E00S OHY145J12E00S OETL-ZX74 Shaft OETL-ZX74 For use with: Length (Inches/mm) Description Weight (Lbs.) OS30AJS30 & OS30ACCS30 OS60GJS30 & OS100GJS30 OES200J3-S & OES400J3- 6.7/170 8.3/210 12.8/325 .20 x .20" (5 x 5mm) .24 x .24" (6 x 6mm) .47 X .47" (12 X 12mm) 0.08 0.10 0.90 Catalog number OXP6X170 OXP6X210 OXP12X325 Terminal lug kits For use with: Wire size Weight Wire type Lugs per kit OS30AJS30 & OS30ACCS30 OS60GJS30 OS100GJS30 OES200J3-S OES400J3-S #18 - 8 #14 - 4 #14 - 2/0 #6 - 300 kcmil #2 - 600 kcmil -- -- 0.43 0.93 3.50 Cu Cu Cu/Al Cu/Al Cu/Al -- -- 6 6 6 19 Catalog number Integral Integral OZXA-24 OZXA-25 OZXA-26 OZXA-24 19.23 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h Di witc ible s us F Special configurations Shaft operated flange 30A - 100A For a complete assembly, please select one of each. + + + Switch Handle Shaft Lug kit (as required) 30A -100A Flange operated fusible switches (Shaft) -- 3 pole Maximum horsepower rating UL general purpose amp rating UL fuse type 600V A 240V 480V 600V 7.5 7.5 15 30 15 15 30 60 20 20 50 75 OS30FAJF30 OS30FACCF30 OS60GJF30 OS100GJF30 UL/ NEMA type Marking Defeatable Padlockable Catalog number 1, 3R, 12 4, 4X OFF/ON OFF/ON Yes Yes Yes Yes DSFHN-HS12 DSFHN-HS4 30 30 60 100 OS30FAJF30 Catalog number Three phase J CC J J Flange handles Shafts DSFHN-HS__ DSFHS-__ Maximum enclosure depth (inches) OS30_ - OS100_ 16 21 26.5 Catalog number DSFHS-12 DSFHS-17 DSFHS-22 Terminal lug kits and accessories Catalog number For use on: Description Wire size Wire type Qty. OS30_ OS60_ OS100_ Lug Lug Lug #18 - #8 #14 - #4 #14 - 2/0 Cu Cu Cu/Al --6 Integral Integral OZXA-24 OS30_- OS100_ Aux. Contact Aux. Contact 1 NO 1 NC 1 1 OA1G10 OA3G01 OS30_ Adapter OS100_ 19 For use with: Shroud Needed for mounting aux. Contacts on OS30_ Includes one set of 3 for use on line or load side 1 OSZ4 1 OSS160GG1L/3 OSS160GG1S/3 Door hardware NEMA 12 Item OZXA-24 Safety door latch, 2 point, door less than 40" high Safety door latch, 3 point, door greater than 40" high Catalog number KDH2R KDH3R Flange operated fusible and non-fusible disconnect switches ABB's solution for complying with the NFPA79 requirements is Flange Operated Fusible and Non-fusible Disconnect Switches. NFPA 79 changes requires main disconnecting means to be operable without the use of accessory tools or devices, independent of door position. This code also includes an interlocking provision to prevent the closing of disconnects while the enclosure door is open, unless an interlock is operated by a deliberate action. OA1G__ The flange operated disconnect switches are available as ridged shaft or flexible cable operated versions. The cable operated version allows you to install the disconnect switch virtually anywhere in the enclosure depending on the length of the cable. Cables are available in lengths up to 84 inches. The designs are cost-effective NFPA 79 solutions offering quick and easy installation. 19.24 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tche ect sib s le Special configurations Cable operated flange 30A - 800A For a complete assembly, please select one each of the following: + + Switch + Handle + Cable Lug kit (as required) Operating mechanism Fusible UL general purpose amp rating UL fuse type 600V 30 30 60 60 100 200 400 600 800 J CC J J J J J J L OS200J03 Catalog number OS30FAJ12 OS30FACC12 OS60GJ12 OS60GJ30 OS100GJ30 OS200J30 OES400J3-FC 1 OES600J3-FC 1 OES800L3-FC 1 Flange handles -- UL98; File #E101914 For use with: Environmental rating OS30_12, OS60GJ12, OS60GJ30, OS100GJ30, OS200J30 OHF1C12 OHF1C12 NEMA 4, 4X OHF1C4 OES400_, OES600_, OES800_ NEMA 4, 4X K7FCH4 For use with: Cable length (inches) Catalog number 36 48 60 72 84 48 60 72 84 OXC1L36 OXC1L48 OXC1L60 OXC1L72 OXC1L84 K7C048 K7C060 K7C072 K7C084 Flexible cables OS30_12, OS60GJ12, OS60GJ30, OS100GJ30, OS200J30 OXC1L36OXC1L84 NEMA 1, 3R, 12 Catalog number OES400_, OES600_, OES800_ Operating mechanisms For use with: Catalog number OS30AFJ12, OS30AFCC12 MKCS2 OS60GJ12 OS60GJ30, OS100GJ30 , OS200J30 OES400 - OES800 MKCS3 MKCS4 Included 19 1 Operating mechanism is included. 19.25 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h Di witc ible s us F Special configurations Cable operated flange 30A - 800A Terminal lug kits For use with Wire size Wire type Description Lugs per kit Catalog number OS100GJ30 #4 - 300 kcmil #4 - 300 kcmil (6) #4-6 AWG #2 - 600 kcmil #2 - 600 kcmil (2) #2 - 500 kcmil (12) #14 - 6 kcmil (2) #2 - 600 kcmil (2) #2 - 600 kcmil Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Distribution lug Distribution lug Distribution lug 6 3 3 6 3 6 3 6 3 OZXA-24 OZXA-200/3 OZXA-206S OZXA-26 OZXA-26/3P OZXA-33 OZXA-175/400 OZXA-27 OZXA-27/3P OS200J30 OES400 Lug Kit OES600 - OES800 Door hardware NEMA 12 Catalog number Item OZXA-200 Safety door latch, 2 point, door less than 40" high Safety door latch, 3 point, door greater than 40" high KDH2R KDH3R Terminal shrouds For use on Description Weight (lbs.) Catalog number OS100 1 Pole 0.04 OSS160T1 OS100 3 Pole 0.12 OSS160T3 OS200 3 Pole Long Type Shroud 0.2 OSS200G1L/3 OS200 3 Pole Short Type Shroud 0.13 OSS200G1S/3 OES400 3 Pole (includes one shroud for line and load side) 0.13 OESA-ZX123 OES600 3 Pole (includes one shroud for line and load side) 0.13 OESA-ZX125 OES800 3 Pole (includes one shroud for line and load side) 0.11 OESA-ZX125 19 19.26 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con n i Fu tche ect sib s le Other configurations High speed fuse pattern Special type fuses For a complete assembly, please select one of each: 1 switch body 1 adapter kit 1 shaft 1 handle + + OESA_R_ + OESAZX_ OXP_ OH_ Selecting switch bodies and adapter kits Please select switch body and adapter kit according to your fuses. Switch body alone can not be used -- an adapter kit is always needed. Switch bodies - 200 A through 800 A American standard Maximum horsepower rating three phase UL general purpose amp rating 240 V 480 V 200 400 600 800 200 400 600 800 60 125 200 250 60 125 200 250 125 250 400 500 125 250 400 500 Weight 600 V Max. allowed fuse power dissipation at rated current 150 350 500 600 150 350 500 600 22W 45W 60W 65W 22W 45W 60W 65W 15.21 17.20 37.48 37.48 17.4 19.4 46.3 46.3 Fuse adapter kits -- for switches OES200 - OES400 Fuse standard American standard DIN80 (DIN43653) DIN80 sizes 00 and 000 (DIN 43653) DIN110 (DIN43653) DIN140 (DIN43653) Flush-end, 70mm body Flush-end, 50mm body French French with micro switches DIN 43653 Fuse adapter kits -- for switches OES600 - OES800 Fuse standard American standard DIN80, DIN 110, DIN 140 (DIN43653) Flush-end, 50mm and 70mm body French French with micro switches Catalog number OES200R03 OES400R03 OES600R03 OES800R03 OES200R04 OES400R04 OES600R04 OES800R04 For 3 pole switch For 4 pole switch Catalog number Catalog number OESAZX1-S4 OESAZX1-S5 OESAZX1-S7 OESAZX1-S9 OESAZX1-S2 OESAZX1-S6 OESAZX1-S8 OESAZX1-S3 OESAZX1-S10 OESAZX1-S11 OESAZX1-S4/4 OESAZX1-S5/4 OESAZX1-S7/4 OESAZX1-S9/4 OESAZX1-S2/4 OESAZX1-S6/4 OESAZX1-S8/4 OESAZX1-S3/4 OESAZX1-S10/4 OESAZX1-S11/4 For 3 pole switch For 4 pole switch Catalog number Catalog number OESAZX2-S4 OESAZX2-S2 OESAZX2-S3 OESAZX2-S5 OESAZX2-S6 OESAZX2-S4/4 OESAZX2-S2/4 OESAZX2-S3/4 OESAZX2-S5/4 OESAZX2-S6/4 Flush end Handles and shafts -- see pages 19.30 - 19.32. Selecting the right fusible disconnect for HSF fuses may be difficult. Due to UL restrictions it is not possible to give a general fuse selection table for your use. Therefore we ask you to contact ABB Inc., in application issues. Information needed is nominal current of the application and catalog number of the fuse. French style 1 Consult Factory. 19.27 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A 19 ct ne s n o e sc h Di witc ible s us F Other configurations High speed fuse pattern Standard switches For a complete assembly, please select one switch catalog number which includes: Switch body + shaft + handle Selecting switch bodies There are some HSF fuses that fit in standard pattern fusible disconnects, no adapter kits needed. DIN-type fusible disconnects - 32-1200A IEC Amp rating DIN 43620 32 63 160 250 400 630 800 1200 AC23A operational power in kW 400V 15 30 75 145 230 355 450 560 500V 18.5 37 90 170 280 450 560 710 Fuse Type Weight (kg) DIN 000 DIN 000 DIN 000, 00 DIN 0, 1 DIN 0, 1, 2 DIN 3 DIN 3 DIN 4 1.3 1.3 1.5 4.3 7.1 13.6 13.6 46 3 Pole Catalog number OS32GD03 OS63GD03 OS160GD03 OS200D03 OS400D03 OS630D03 OS800D03 OS1250D03 4 Pole Catalog number OS32GD04F OS63GD04F OS160GD04F OS200D04F OS400D04F OS630D04F OS800D04F OS1250D04F NFC-style Fusible disconnects - 25-125A IEC Amp rating NFC Style 25 32 50 125 AC23A operational power in kW 400V 11 15 22 55 500V 15 18.5 30 75 Fuse Type Weight (kg) NFC 10x38 NFC 14x51 NFC 14x51 NFC 22x58 0.7 0.7 1.3 1.5 3 Pole Catalog number OS25FF1210 OS32FF1214 OS50GF12 OS125GF12 4 Pole Catalog number OS25FF2210F OS32FF2214F OS50GF22F OS125GF22F BS-types fusible disconnects - 32-1200A IEC Amp rating 32 63 100 160 200 400 630 800 1250 AC23A operational power in kW 400V 15 30 55 75 145 230 355 450 560 500V 18.5 37 55 90 170 280 450 560 710 Fuse Type Weight (kg) A2,A3 A2,A3 A2, A3, A4 A2, A3, A4 B1-B2 B1-B4 C1-C2 C1-C3 D1 1.3 1.3 1.5 1.5 3.3 7.1 13.6 13.6 46 3 Pole Catalog number OS32GB03 OS63GB03 OS100GB03 OS160GB03 OS200B03 OS400B03 OS630B03 OS800B03 OS1250B03 4 Pole Catalog number OS32GB04N1 OS63GB04N1 OS100GB04N1 OS160GB04N1 OS200B04N2 OS400B04N2 OS630B04N2 OS800B04N2 OS1250B04N2 19 19.28 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Non-fusible & fusible disconnect switch Disconnect switch accessories Non-fusible & fusible Di s sw con Ac itc ne ce he ct ss s ori es Accessories IO N 19 19.29 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e s sc h Di witc sorie s es c Ac Standard handles & shafts 12 OHBS2AJ1 OHB__J6 OHY__J6 YASDA-8 OHM125L12 OHB4 Recommended handles & shafts Amperes Shaft diameter Recommended standard pistol handle length Maximum recommended shaft length 16 - 100 200 400 - 1200 1600 - 3150 6x6 mm - .24 x .24" 6x6 mm - .24 x .24" 12x12 mm - .47 x .47" 12x12 mm - .47 x .47" 45 - 65 mm 65 - 80 mm 125 - 274 mm 175 - 330 mm 290 mm 290 mm 595 mm 595 mm Selector handles -- for use with .24 x .24" (6mm) OXS6X_shafts UL/NEMA Type IEC type Color Marking 1 IP54 Black O/I & Off/On 1, 3R, 12 IP65 Black O/I & Off/On Defeatable Padlockable Weight (lbs) Catalog number -- -- -- Yes -- Yes Yes Yes 0.09 0.12 0.16 0.16 OHBS1AH1 3 OHBS3AH1 3 OHBS2AJ1 3 OHBS2AJ 3 Pistol handles -- for use with .24 x .24" (6mm) OXP6X_ shafts UL/NEMA Type IEC type Color Marking Length in/mm Defeatable Padlockable Weight (lbs) Catalog number 2.6/65 2.6/65 3.1/80 2.6/65 3.1/80 2.6/65 2.6/65 2.6/65 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.29 0.29 0.30 0.29 0.30 1.60 0.31 0.31 OHB65J6 OHB65J6T 4 OHB80J6 OHB65L6 OHB80L6 OHM65L6 OHB65J6EH OHB65L6EH 1, 3R, 12 IP65 Black O/I & Off/On Off/On/Test O/I & Off/On 1, 3R, 12, 4, 4X IP66 Black O/I & Off/On 1, 3R, 12, 4, 4X 1, 3R, 12 1, 3R, 12, 4, 4X IP66 IP65 IP66 316L Stainless steel Black w/ 316 stainless hasp Black w/ 316 stainless hasp O/I & Off/On O/I & Off/On O/I & Off/On Pistol handles -- for use with .47 x .47" (12mm) OXP12X_ shafts UL/NEMA Type 1, 3R, 12 IEC type IP65 Color Marking IP66 1, 3R, 12, 4, 4X IP65 IP66 1, 3R, 12, 4, 4X 1 2 3 4 IP65 IP66 Catalog number 4.9/125 Yes Yes 0.39 OHB125J12 Yes Yes 0.39 OHB145J12 OHB175J12 Black 6.9/175 Yes Yes 0.41 7.9/200 Yes Yes 0.88 OHB200J12P 10.8/274 Yes Yes 1.19 OHB274J12 Black Steel Reinforced 13/330 Yes Yes 1.28 OHB330J12 Black 5.7/145 Yes Yes 0.39 OHB145L12 Black 6.9/175 Yes Yes 0.41 OHB175L12 7.9/200 Yes Yes 0.88 OHB200L12P 10.8/274 Yes Yes 1.19 OHB274L12 13/330 Yes Yes 1.28 OHB330L12 8.7/220 -- Yes 1.50 YASDA-8 4.9/125 Yes Yes 1.7 OHM125L12 6.9/175 Yes Yes 1.8 OHM175L12 10.8/275 Yes Yes 2.1 OHM275L12 7.9/200 Yes Yes 0.88 OHM200L12P 4.9/125 Yes Yes 0.44 OHB125J12EH 6.9/175 Yes Yes 0.76 OHB175J12EH 4.9/125 Yes Yes 0.44 OHB125L12EH 6.9/175 Yes Yes 0.76 OHB175L12EH Black T-Handle O/I & Off/On Black T-Handle O/I & Off/On Metal 316L Stainless Steel Off/On O/I & Off/On T-Handle 1, 3R, 12 Weight (lbs) 5.7/145 Black Steel Reinforced 1, 3R, 12, 4, 4X Padlockable Black Black Steel Reinforced 19 Defeatable Black Black Steel Reinforced 1, 3R, 12, 4, 4X Length in/mm Black w/ 316 stainless hasp Black w/ 316 stainless hasp O/I & Off/On O/I & Off/On Red/Yellow handles are available by substituting the OHB prefix with OHY. All handles are plastic unless otherwise noted as metal or stainless steel. Not recommended for use on OT30/60/100. The OS30_ switch has a TEST position, accessed by rotating the mechanism 45 degrees counterclockwise from the OFF position. In the TEST position, optional auxiliary contacts, OA4B1C, are actuated but the main switch contacts are not. 19.30 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Ac itc ne ce he ct ss s ori es Standard handles & shafts 2 Direct mount handle for non-fusible switches Description Mounts directly on switch. No shaft necessary For use on Color Padlockable Shaft through handle Weight OT16-40 Black Yes Yes 0.05 Yes 0.05 No Yes Yes Yes Yes Yes 0.22 0.44 0.66 0.30 0.30 0.80 OT63-80 OT30/60/100 OT200 OT400 OT600 OT800 OT1200 OETL-NF1600-OETL-NF3150 Up to 3 padlocks in OFF-position, includes shaft and mechanism Mounts on shaft Yes No Yes Yes Yes Yes Yes Yes No Black Black Black Black Black Black Metal Shaft catalog number Switch catalog number OHBS12 3 CXBY68989 OHBS23 CXBY68998 CXBY68419/6/2M OTV250EK OTV400EK OTV800EK OTV1000EK OTV1000EK YASDA-34 Direct mount handle for fusible switches For use on Description Marking Color Padlockable Weight OS30 OS60 - OS200 OS400 OS600 OS400-600, OES800 No shaft required No shaft required No shaft required No shaft required Mounts on 12mm shaft O/I/Test O/I O/I O/I -- Black Black Black Black Metal Yes Yes Yes Yes No 0.10 0.30 0.30 0.30 0.78 Catalog number OHBS5 OSV200BK OSV400BK OSV800BK YASDA-33 3 Position selector handles for double throw switches UL/NEMA Type IEC Type Markings Color Defeatable Padlockable Weight (Lbs.) 1, 3R, 12 IP65 I/0/II, ON/OFF/ON Black Yes Yes 0.16 Catalog number OHBS2AJE011 3 Position pistol handles for double throw switches UL/NEMA Type IEC Type 1, 3R, 12 1, 3R, 12, 4, 4X 1, 3R, 12 1, 3R, 12, 4, 4X IP65 IP66 IP65 IP66 Markings I/0/II, ON/OFF/ON Color Defeatable Padlockable Weight (Lbs.) Black Black Black Black Yes Yes Yes Yes Yes Yes Yes Yes 0.29 0.29 0.3 0.3 Catalog number OHB65J6E011 OHB65L6E011 OHB80J6E011 OHB80L6E011 Catalog number OHB145J12E011 OHB145L12E011 OHB175J12E011 OHB175L12E011 Selector handles for door mounted switches 1 UL/NEMA Type IEC Type Snap-on mounting - for use on OT16FT3 - OT40FT3 1 IP54 1 IP54 1, 3R, 12 IP65 Catalog number Color Defeatable Padlockable Weight (lbs) Black Black Black -- -- -- -- Yes Yes 0.10 0.13 0.17 OHBS1PH OHBS3PH OHBS2PJ -- Yes Yes 0.11 0.14 0.18 OHBS1RH OHBS3RH OHBS2RJ Screw mounting - for use on OT16FT3 - OT100FT3. For OT30, OT60, and OT100 use OH_ _2_ only 1 IP54 Black -- 1 IP54 Black -- 1, 3R, 12 IP65 Black -- 19 1 Red/Yellow handles are available by substituting the OHB prefix with OHY. 2 All handles are plastic unless otherwise noted as metal or stainless steel. 3 Suitable for 3 & 4 pole versions only. Not for use with 6 or 8 pole or double throw configurations. 19.31 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e s sc h Di witc sorie s es c Ac Standard handles & shafts OXP6X OXP12X_ OXS6X__ Shafts for use with selector handles - .24 x .24" (6x6 mm) Maximum Mounting Depth (inches) 1 Shaft length (in/mm) 3.3/85 4.1/105 4.7/120 5.1/130 7.1/180 9.8/250 13/330 OT16F3, OT25F3, OT40F3 OT63F3, OT80F3 OH_1_ & OH_3_ OH_2_ OH_1_ & OH_3_ OH_2_ 5.0 5.8 6.4 6.7 8.7 11.5 14.6 4.3 5.1 5.8 6.1 8.1 10.8 14.0 5.6 6.4 7.0 7.4 9.4 12.1 15.3 5.0 5.8 6.4 6.8 8.7 11.5 14.7 OS30 2 Weight - - - 5.6 6.1 10.3 13.4 0.07 0.07 0.08 0.08 0.11 0.13 0.17 Catalog number OXS6X85 OXS6X105 OXS6X120 OXS6X130 OXS6X180 OXS6X250 OXS6X330 Shafts for use with pistol handles - .24 x .24" (6x6 mm) Maximum Mounting Depth (inches) Shaft length (in/mm) OT16F3 - OT40F3 OT63F3 - OT80F3 OT30F3/60F3/100F3 5.2/130 5.9/150 8.3/210 11.4/290 14.2/360 16.9/430 5.9 6.7 9.1 12.2 14.9 17.6 6.4 7.4 9.7 12.8 13.8 18.3 6.7 7.0 9.8 12.9 15.6 18.3 Weight OT200 OS30 OS60 OS100 OS200 6.5 7.2 9.6 12.7 15.5 18.2 - 8.9 9.7 13.4 18.7 22.6 - 9.7 12.1 15.2 12.9 20.6 - 9.8 12.2 15.3 18.0 20.7 - 9.9 13.0 - - - 0.08 0.09 0.13 0.18 0.23 0.27 Catalog number OXP6X130 OXP6X150 OXP6X210 OXP6X290 OXP6X360 OXP6X430 Shafts for use with pistol handles - .47 x .47" (12x12 mm) Shaft length (in/mm) Maximum Mounting Depth (inches) Weight 19 11.0/280 12.8/325 15.6/395 18.3/465 21.1/535 OT400 OT600 OT800 - OT1200 OETL-NF1600 OETL-NF3150 OS400 OS600 - OS1200 13.3 15.0 20.5 21.9 22.8 14.6 16.4 19.1 21.8 24.6 14.5 16.3 19.1 21.9 24.6 -- 20.9 23.6 26.3 29.1 13.8 15.6 18.3 21.0 23.8 14.9 16.7 19.4 22.1 24.8 0.77 0.90 1.10 1.32 1.54 Catalog number OXP12X280 OXP12X325 OXP12X395 OXP12X465 OXP12X535 1 Mounting depth is distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. 2 Selector handles and shafts are not recommended for use with fusible switches over 30A. 19.32 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Ac itc ne ce he ct ss s ori es Auxiliary contacts (N)7 L4 3 OT16E (N)8 T4 I ON N N N PE N N N PE O OFF Auxiliary contacts -- snap-on mounting 1 Description For Use On Weight AC Thermal amp rating AC rated voltage Form C 1 N.O. & 1 N.C. OS30 2 OT16-100, OT200-1200 OS30-OS1200 OT16-100 0.04 6 250 OA4B1C 0.07 10 600 OA1G10 0.07 10 600 OA1G01 0.07 10 600 OA3G01 0.07 0.09 10 - 600 - OA2G11 OSZA 0.1 - - OEA28 4 For Use On Weight AC Thermal amp rating AC rated voltage OETL-NF1600 through OETL-NF3150 0.2 0.26 0.4 0.18 0.25 0.4 10 10 10 10 10 10 600 600 600 600 600 600 Weight (Lbs.) AC Thermal amp rating AC rated voltage 0.7 0.7 0.7 10 10 10 600 600 600 1 N.O. 1 N.C. OT200-1200 OS30-OS1200 1 N.O. & 1 N.C. OT16-100 OS30 OT200-1200 OS200-OS1200 Module for auxiliary contacts Catalog number OEA28 Auxiliary contacts -- front mounting 3 Description OA1G__ 1 N.O. + 1 N.C. 2 N.O. + 2 N.C. 4 N.O. + 4 N.C. 2 N.O. 4 N.O. 8 N.O. Catalog number OZXK-1 OZXK-2 OZXK-3 OZXK-4 OZXK-5 OZXK-6 Auxiliary contacts -- snap-on mounting for double throw Description 1 N.O. 1 N.C. 1 N.O. For Use On OT16-100_C OT16-800_C OT200-800_C Catalog number OA7G10 OA3G01 OA1G10 Mounting & installation considerations OA2G11 Non-Fusible OA1G10 (1 N.O.) mounts on right side of switch only OT16-100 OA1G01 (1 N.C.) mounts on left side of switch only OA2G11 (1 N.O. & 1 N.C.) mounts on left of right side of switch 19 Maximum two contacts on each side of switch OT200-1200 Maximum 8 auxiliary contact blocks with the OEA28 module Maximum 4 auxiliary contact blocks mounting under the mechanisms Fusible Form C contacts mount directly to switch OS30 Maximum two Form C contacts OA1G10 (1 N.O.) + OA3G01 (1 N.C.) require mounting base Maximum 6 OA1G10 + OA3G01 contacts with mounting base OSZ4 OS60-1200 Mounting to left side of switch with OEA28 module: Maximum 8 contact blocks Mounting under mechanism cover: Maximum 4 contact blocks 1 UL file #E83510 2 Not suitable for use on cable operated flange version of OS100 3 UL File #E5707 4 Maximum 8 contact blocks (N.O. or N.C.) with the OEA28 module. 19.33 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e s sc h Di witc sorie s es c Ac Terminal lugs Terminal lugs 1 For Use On OS100 OT200/OS200 OZXA-400 OZXA-27 OT/OS400 OT600 , OS600 - OS800 OT800, OT1200 & OS1200 OETL-NF1600 OZXA-30 OZXA-32 OETL-NF2000-3150 Wire Size #14-2/0 #4 - 300 kcmil #4 - 300 kcmil (6) 14-6 AWG (6) 14-6 AWG #2 - 600 kcmil #2 - 600 kcmil (2) #4 - 300 kcmil (6) #14 - 6 AWG (2) #2 - 600 kcmil (2) #2 - 600 kcmil (4) #2 - 600 kcmil (4) #2 - 600 kcmil (4) #2 - 600 kcmil (4) #2 - 600 kcmil (8) 2/0 + (2) #2 - 600 kcmil 3 (8) #2 - 600 kcmil Wire Type Lugs/Kit Cu/Al Weight (lbs) 6 6 3 3 3 6 3 6 3 6 3 6 3 6 3 3 12 Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al 0.50 0.50 0.25 0.25 0.25 0.50 0.25 0.50 0.50 0.50 0.50 6.90 3.45 10.44 5.22 10.44 20.88 Catalog number OZXA-24 2 OZXA-200 OZXA-200/3 OZXA-206T 4 OZXA-206S 4 OZXA-400 OZXA-400/3P OZXA-402 OZXA-406 OZXA-800 OZXA-800/3 OZXA-1200 OZXA-1200/3 OZXA-28 OZXA-28/3 OZXA-32 OZXA-28/2 Terminal lug kits for double throw switches For Use On Wire Size Wire Type Lugs/Kit Weight (Lbs) Catalog number OT200_C #4 - 300kcmil #4 - 300kcmil Cu/Al 9 12 0.5 0.25 OZXA-200/9 OZXA-200/12 OT400_C #2 - 600kcmil #2 - 600kcmil Cu/Al 9 12 0.5 0.25 OZXA-400/9 OZXA-400/12 OT600_C (2) #2 - 600kcmil (2) #2 - 600kcmil Cu/Al 9 12 0.5 0.5 OZXA-800/9 OZXA-800/12 OT800_C (4) #2 - 600 kcmil (2) #2 - 600 kcmil Cu/Al Cu/Al 9 12 0.5 0.5 OZXA-1200/9 OZXA-1200/12 OZXA-175/400 OZXA-24 OZXA-27 19 OZXA-175/400 1 2 3 4 Lugs are integral to the switch for 16-125A. No separate lug kit accessory is required. Not suitable for use on cable operated flange version OS100. A load side distribution lug eliminates the need to purchase, install and wire a separate distribution block. Comes with OZXA-175 terminal lugs and shrouds. 19.34 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Ac itc ne ce he ct ss s ori es Terminal shrouds Terminal shrouds for non-fusible OTS250G1L/3 Description For Use On Weight 3 pole includes one shroud for line or load side OT16-OT40 2 OT63-OT80 2 OT30-OT100 2 0.02 0.02 0.02 OTS40T3 OTS63T3 OTS125T3 4th pole includes one shroud for line or load side OTPS40FPN1 2 OTPS80FP 2 OTPS125FP 2 0.03 0.03 0.03 OTS40T1 OTS80T1 OTS125T1 3 pole long type shrouds 0.12 OTS250G1L/3 3 pole short type shrouds 0.13 OTS250G1S/3 4 pole long type shrouds OT200 4 pole short type shrouds OTS250G1S/3 Catalog number 0.26 OTS250G1L/4 3.18 OTS250G1S/4 3 pole includes one shroud for line or load side 1 OT400 OT600 0.33 0.33 OTS403 OTS603 3 pole includes one shroud for line or load side 1 OT800 OT1200 0.88 1.2 OTS803 OTS1203 Terminal shrouds for fusible OTS40T3 OTS80T3 OTS125T3 OTS40T1 OTS80T1 OTS125T1 Weight (Lbs.) Terminal shroud for one pole Terminal shroud for 3 poles OS100 OS100 0.04 0.04 OSS160GG1L/3 OSS160GG1S/3 3 pole long type shrouds 3 pole short type shrouds 4 Pole long type shrouds 4 pole Short type shrouds OS200 OS200 OS200 OS200 0.20 0.13 0.26 0.18 OSS200G1L/3 OSS200G1S/3 OSS200G1L/4 OSS200G1S/4 OS400 OS600 0.13 0.11 0.47 1.54 0.62 1.54 0.88 2.12 1.15 2.2 OSS403 OSS603 OSS800G1S/3 OSS800G1L/3 OSS800G1S/4 OSS800G1L/4 OSS1250G1S/3 OSS1250G1L/3 OSS1250G1S/4 OSS1250G1L/4 3 Pole includes one shroud for line or load side 1 3 pole short type shrouds 3 pole long type shrouds 4 pole short type shrouds 4 pole long type shrouds 3 pole short type shrouds 3 pole long type shrouds 4 pole short type shrouds 4 pole long type shrouds OSS160T3 Catalog number For Use On Description OS800 OS1200 OSS200G1S/3 OSS200G1L/3 19 1 For 4 pole shrouds, please consult factory. 2 ABB OT16 - OT100 switches are IP20 touchsafe as standard. Terminal shrouds provide an extra degree of protection. 19.35 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e s sc h Di witc sorie s es c Ac Additional poles Additional poles for non-fusible 1 Power poles - Only one power pole per switch: mounts on left or right side of switch. (OTPS40FPN1 mounts to left side only.) Weight AC Thermal amp rating Fourth Pole OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 Late-break/ early-make OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 Description OTP_40FP For use on AC rated voltage Catalog number 40 60 80 100 600 OTPS40FPN1 OTPS60FP OTPS80FP OTPS125FP 40 60 80 100 600 OTPL40FP OTPL60FP OTPL80FP OTPL125FP Catalog number Terminal poles - Switch accepts one terminal pole per side: mounts on left or right side of switch Description OTP_80FP For use on Weight AC Thermal amp rating AC rated voltage Solid neutral OT16-OT40 OT30-OT60 OT63-OT80 OT30-OT100 0.07 0.13 0.13 0.31 40 60 80 100 600 OTPN40FP OTPN60FD OTPN80FP OTPN125FP Detachable Neutral OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 40 60 80 60 600 OTPD40FP OTPD60FP OTPD80FP OTPD125FP Ground Terminal OT16-OT40 OT30-OT60 OT63-OT80 OT100 0.07 0.13 0.13 0.31 40 60 80 100 600 OTPE40FP OTPE60FP OTPE80FP OTPE125FP OTP_125FP Additional poles for fusible Description For use on Weight (Lbs.) AC Thermal amp rating AC rated voltage Catalog number Detachable neutral mounts on side of switch or DIN rail OS30 OS60 OS100 0.45 0.13 0.31 30 63 125 600 600 600 OESA-ZX171 OSZ1 OSZ2 OESA-ZX171 19 1 Switches accept only one power pole or one terminal pole per side. Only one power pole per switch. 19.36 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Ac itc ne ce he ct ss s ori es Fuse monitors & carriers Fuse monitors Blown fuse indicators/monitors For Use With Rated Voltage Weight (lbs) OS30-1200 100-240 380-600 0.31 0.31 Catalog number OFM240 OFM600 Suitable for 1 or 3 phase circuits. Includes 1 N.O. and 1 N.C. auxiliary contacts and red & green LED lights for indication. OFM_ OSC60J_ Fuse Monitor Mounting Accessories CXBY68362 For Use With Crimp Terminal size (mm) OS30-200 2.8-0.8 OFMZX2 Catalog number OS400-1200 Includes 6 crimp terminals 6.3-0.8 OFMZX4 Fuse carriers/covers Description For Use on CC fuse carrier (Qty. 1) J fuse carrier (Qty. 1) Solid link carrier (Qty. 1) Catalog number OS30AFCC_ OS30AFJ_ OS30_ OESAZD48 OESAZD28 OESAZD55 Shorting bars for fusible switches Description For Use On AC thermal amp rating AC rated voltage Catalog number Dummy Fuse OS60 60 600 OESA-ZD54 Solid links: metal strap OS100 OS200 100 400 600 600 OESA-ZS36 OESA-ZK98 19 19.37 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e s sc h Di witc sorie s es c Ac Miscellaneous accessories Replacement parts Miscellaneous accessories Shaft accessories Accessory Type Shaft Adapter Shaft Extension Coupler Shaft Guide For Use On Weight Adapts one end of a 6mm shaft to 12mm (use with shaft extension coupler) Description Catalog number 6mm shafts 0.20 OETL-ZK19 Joins two shafts together for applications where extended length is required 6mm shafts 12mm shafts 0.26 0.26 OESA-ZX167 OETL-ZX95 Fits all pistol grip handles, mounts on the inside of the enclosure door with provided hardware pistol handles - Description For Use On Weight Vertical, back or edgewise mounting 1 OETL-NF1600 - 3150 46.2 31.0 OHZX10 Busbar connections OETL-ZT80_ Accessory Type Busbar Connections Catalog number OETL-ZX115 OETL-ZX114 Locking accessories Accessory Type Cam Attachment OETL-ZX115 Description For Kirk Key, Castell, Low & Fletcher and Ronis interlock. For adapting to the interlock system. The interlock is not included. Closed circuit principle for interlocking the switch movement. When the coil circuit is dead, A-types cannot be operated to O-position and L-types cannot be operated to ON- or OFFElectrical Interlock position. Coil voltages 110VAC, 220 VAC, 24VDC, 48VDC, 60VDC, 110VDC, 220VDC, P - 15W U = 0.7 - 1.1 Un (U = coil voltage, Un = nominal voltage) For Use On Weight OS60-OS200 0.25 OETL-ZW16 Catalog number OS400OS1200 0.29 OETL-ZW5 OETL-NF800 - 3150A, OES800 2.42 OETL-ZT80A OETL-ZT80L = Coil Voltage OETLZX114 Replacement parts Accessory Type Description For Use On Catalog number Non-fusible OTZS2 Metal collar Replaces original black knob for locking shaft in place Set screw Set screw for use with knob or collar Shaft set screw Shaft set screw, bag of 10 OT16-200, OS30-200 OT16-200 OS30-200 OT400-1200 OTZS2 FLSWM5X8AX OZX1 Fusible Terminal cover Covers terminal below fuse carrier OS30 CXBY67121 Phase barrier - OS200 CXBY68794 FLSWM5X8AX Shaft Set Screw Fuse covers - OS30_ Bag of 10 OS400-1200 - OS100GJ_ OZX1 CXBY69058 CXBY69072 19 1 Vertical busbar is provided as standard on OETL-NF1600 through OETL-NF3150 switches. 19.38 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Ac itc ne ce he ct ss s ori es Conversion, transfer & bypass mechanisms Mechanical interlocks Conversion mechanisms Mechanism Type For use on 6 or 8 pole mechanisms Double throw mechanisms OTZW8 Weight - OTZW8 OETL-ZK19 OESA-ZW2 OETL-ZW9 OT16 - 160 2.20 1, 3R, 12 1, 3R, 12, 4, 4X OESA-ZW1 OESA-ZW1X OT200 OS30-200 2.20 1, 3R, 12 1, 3R, 12, 4, 4X OTZW25 OTZW25X 10.10 1, 3R, 12, 4, 4X OETL-ZW12 1.54 1, 3R, 12 1, 3R, 12, 4, 4X OTZW17 OTZW17X OT16-OT100 Mechanical interlock mechanisms Catalog number 0.33 1.52 1.52 2.42 OT400 - OETL-NF1200 Bypass mechanisms UL/Nema Type OT16-100 OT160 OS30-200, OT200 OT400 - OETL-NF1200 OT200, OS30-200 7.28 1, 3R, 12 OT400 - OETL-NF1200 8.81 1, 3R, 12, 4, 4X OTZW26 OETL-ZW13 OT16-OT100 OT160-200, OS30-200 OT400 - OETL-NF800 OETL-NF1200 - OETL-NF3150 0.33 0.55 1.26 2.64 - OTZW24 OTZW10 OETL-ZW3 OETL-ZW15 6 or 8 pole IO N OTZW6 6 (8) pole mechanism allows two switches controlled by one handle to open or close simultaneously. Equipment required for a complete installation: * One conversion mechanism * Two disconnect switches (see page 19.11) * One handle1 (see page 19.30) * Two shafts (see page 19.32) 2 O X SW. B O X X = Closed O = Open 2 Transfer Transfer mechanism manually transfers between two power sources using two switches and a center OFF position. A 3-position handle is included. Shafts included. Equipment required for a complete installation: * One conversion mechanism * Two disconnect switches (see page 19.11.) POS. I POS. O POS. II SW. A X O O SW. B O O X X = Closed O = Open Bypass 2 Bypass mechanism operates three switches: Two switches in series and one changeover switch to allow power bypass. A 3-position handle is included. Shafts included.Equipment required for a complete installation: * One conversion mechanism * Three disconnect switches (see page 19.11.) OTZW17 POS. O POS. I SW. A POS. I POS. O POS. II SW. A O O SW. B O O X X SW. C X O O X = Closed O = Open 19 Mechanical interlock Mechanical interlock mechanism prevents both switches from being in the ON position at the same time. Equipment required for a complete installation: * One conversion mechanism * Two disconnect switches (see page 19.11) * Two handles (see page 19.30) * Two shafts (see page 19.32) SW. A POS. I SW. B POS. I SW. A X O SW. B O X 1 X = Closed O = Open OETL-ZW24 1 OT16E3 - OT32E3 can use a selector or pistol handle. All other sizes must use a pistol handle. 2 = Three poles 19.39 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e s sc h Di witc sorie s es c Ac Notes 19 19.40 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con En itch nect clo es se d eOT, NF and FJ's meet customer requirements in terms of safety, ease of installation, space savings and operational convenience. They are available in a wide range of amperage ratings, are UL approved and NEMA rated to satisfy rugged industrial environments. Enclosed Disconnect switches Enclosed disconnect switches 16A - 3150A Non-fusible 30A - 1200A Fusible 19 19.41 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h Di witc sed s clo En General information Non-fusible, fusible & lockable Non-fusible Modern appearance Snap on accessories include additional poles, auxiliary contacts, etc. Quick make, quick brake mechanism Enclosures available in plastic, metal, or stainless steel in NEMA 1, 3R, 12, 4X, 7 & 9 environmental categories Heavy duty disconnect, 600VAC Extremely compact size Finger-proof construction. No hazardous exposed parts 3/4/6/8 pole constructions; transfer switches and by-pass switches available Fusible Modern appearance Snap on accessories include fuse monitors, auxiliary contacts, etc. Quick make, quick brake mechanism Enclosures available in plastic, metal, or stainless steel in NEMA 1, 3R, 12, 4X, 7 & 9 environmental categories Heavy duty disconnect, 600VAC, 200kA, Isc Extreme compact size as fuse carriers are decked above contacts Double contacts enabling feed from any direction and preventing back feed Finger-proof construction. No hazardous exposed parts 3/4/6/8 pole constructions; transfer switches and by-pass switches available Lockable 19 Clear position indications: I-ON O-OFF Door interlocked when handle is in ON position. Door interlock can be defeated by authorized personnel. Door interlocked when handle padlocked to OFF position Pilot devices can be added Handle padlockable with up to three padlocks 19.42 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con En itch nect clo es se d General information Non-fusible, 16A - 3150A Fusible, 30-1200A Switch ratings, 16 - 3150 Amps, 600V UL 98 UL 508 UL General purpose amp rating 120V 16 1 25 1.5 40 2 60 2 80 2 30 2 60 3 100 5 125 7.5 200-- 400 -- 600 -- 800 -- 1200 -- 1600 -- 2000 -- 3150 1 -- Maximum horsepower rating Single phase Three phase 200V 240V 200V - 208V 240V 480V 600V 2 3 5 5 5 5 7.5 15 20 -- -- -- -- -- -- -- -- 2 3 5 5 5 5 7.5 15 20 -- -- -- -- -- -- -- -- 3 7.5 10 15 20 10 20 25 30 60 100 150 200 -- -- -- -- 5 7.5 10 15 20 10 20 30 30 75 125 200 250 -- -- -- -- 10 15 20 30 40 20 40 50 75 150 250 400 500 -- -- -- -- 10 20 25 30 40 30 40 50 100 200 350 500 600 -- -- -- -- Wire size for terminal lugs #18 #18 #18 #14 #14 #14 #14 #8 #8 #6 #2 (2) #2 (2) #2 (4) #2 (4) #2 (8) #2 (8) #2 - - - - - - - - - - - - - - - - - 8 8 8 1 1 4 4 1/0 1/0 300 kcmil 600 kcmil 600 kcmil 600 kcmil 600 kcmil 600 kcmil 600 kcmil 600 kcmil For wire type Approval Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL UL IEC Handle ratings Catalog number Style suffix type S S1 P P P1 P1 BJ YJ B4 B4 B4 Y4 B6 Y6 B7 B7 B7 Y7 B8 B8 B8 Y8 6 8 21 21 Selector Selector Pistol Pistol Pistol Pistol Selector Selector Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol Pistol NEMA Color Marking Defeatable Padlockable 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,12 1,3R,4,4X,12 1,3R,12 1,3R,12 1,3R,12 1,3R,12 1,3R,4,4X,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,4,4X,12 Black Red/Yel Black Black Red/Yel Red/Yel Black Red/Yel Black Black Black Red/Yel Black Red/Yel Black Black Black Red/Yel Black Black Black Red/Yel Black Metal Metal Black O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON I/O/II I/O/II O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON O/I & OFF/ON I/O/II I/O/II O/I & OFF/ON O/I & OFF/ON I/O/II I/O/II O/I & OFF/ON I/O/II O/I & OFF/ON I/O/II I/O/II Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Catalog number OHBS2AJ OHYS2AJ OHBS65J6 OHBS65L6 OHYS65J6 OHYS65L6 OHBS2AJ OHYS2AJ OHB145J12 OHB145J12E011 OHB145L12E011 OHY145J12 OHBS65J6 OHYS65L6 OHB175J12 OHB175J12E011 OHB175L12E011 OHY175L12 OHB80L6 OHB80J6E011 OHB80L6E011 OHY80L6 OHB174L12E011 YASDA-8 YASDA-21 OHB274L12E011 1 IEC rated only. 2 Switches are for double throw. 19.43 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A 19 ct ne s n o e sc h Di witc sed s clo En General information Fusible, 30A - 1200A Switch ratings Maximum horsepower rating 120V 200V 240V 200V 208V 240V 480V 600V 30 60 100 200 400 600 800 1200 2 3 5 -- -- -- -- -- 3 7.5 10 -- -- -- -- -- 5 10 15 -- -- -- -- -- 5 15 25 50 100 150 200 -- 7.5 15 25 50 125 150 200 -- 7.5 15 30 60 125 200 250 -- 15 30 60 125 250 400 500 -- 20 50 75 150 350 500 600 -- UL 98 UL general purpose amp rating Single phase Three phase Wire size for terminal lugs #18 #14 #14 #6 #2 (2) #2 (2) #2 (4) #2 - - - - - - - - 8 4 2/0 300 kcmil 600 kcmil 600 kcmil 600 kcmil 600 kcmil For wire type Approval 1 Cu Cu Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL CSA, UL Enclosed non-fused, 3 poles, 16 to 100 A EOT 16 U 3 M 1 - 1 P Size and Amps 16 = 16A 30 = 30A 32 = 40A 45 = 60A 60 = 60A 63 = 80 100 = 100A Poles 3 Enclosure P = Plastic S = Stainless steel M = Sheet steel Type 1 = Type 1 3 = Type 3R/12 4 = Type 4/4X Auxiliary contact [Blank] - None 0 = 1 N.C. 1 = 1 N.O. Handle P = Pistol Black S = Selector Black M = Metal (OHM...) Enclosed non-fusible, 200 - 1200 A and specialty configurations NF 200 1 - 6 P B6 C Style EOT - Non-fused (16-100A) NF - Non-fused (200-1200A) FJ - Fused "J" type fuses (30-800A) FC -Fused "CC" type fuses (30-800A) Amps 200 400 600 800 1200 1600 2000 Type 1 = Type 1 3 = Type 3R/12 4 = Type 4 X = Type 4X Poles 3 6 Configuration P = Standard T = Double Throw Handle B = Black 1 Y = Red/Yellow 1 Revision 19 Custom versions or other versions of enclosed products are available upon request... please consult factory. 1 Fusible switches are UL listed to the UL98 standard. 19.44 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con En itch nect clo es se d 3 pole Non-fusible, 16A - 3150A NF32X-3PB6C EOT16U3P3-S EOT63U3M1-P 3 pole, 600V, 16-80A Selector handle UL/NEMA Enclosure Type UL general purpose amp rating 1 3R/12 4/4X 3R/12 Plastic Catalog number Catalog number Catalog number Catalog number 16 EOT16U3M1-S EOT16U3M3-S 40 EOT32U3M1-S EOT32U3M3-S 60 EOT45U3M1-S EOT45U3M3-S 80 EOT63U3M1-S EOT63U3M3-S Not available with selector handles EOT16U3P3-S EOT32U3P3-S EOT45U3P3-S EOT63U3P3-P 3 pole, 600V, 16-100A Pistol handle UL/NEMA Enclosure Type UL general purpose amp rating 1 3R/12 4 4X Stainless 4X Plastic 7&9 Catalog number Catalog number Catalog number Catalog number Catalog number Catalog number 16 EOT16U3M1-P EOT16U3M3-P - EOT16U3S4-P EOT16U3P4-P NF167-3P 40 EOT32U3M1-P EOT32U3M3-P - EOT32U3S4-P EOT32U3P4-P NF327-3P 60 EOT45U3M1-P EOT45U3M3-P - EOT45U3S4-P EOT45U3P4-P NF457-3P 80 EOT63U3M1-P EOT63U3M3-P - EOT63U3S4-P EOT63U3P4-P NF637-3P 30 EOT30U3M1-P EOT30U3M3-P - EOT30U3S4-P NF30P-3PB6C NF307-3P 60 EOT60U3M1-P EOT60U3M3-P - EOT60U3S4-P NF60P-3PB6C NF607-3P 100 EOT100U3M1-P EOT100U3M3-P - EOT100U3S4-P NF100P-3PB8C NF1007-3P 3 Pole, 600V, 200A - 3150A Pistol handle UL/NEMA Enclosure Type UL general purpose amp rating 1 3R/12 4 4X Stainless 4X Plastic 7&9 Catalog number Catalog number Catalog number Catalog number Catalog number Catalog number 200 NF2001-3PB8B NF2003-3PB8B NF2004-3PB8B NF200X-3PB8B NF200P-3PB8B -- 400 NF4001-3PB4B NF4003-3PB4B NF4004-3PB4B NF400X-3PB4B NF400P-3PB4B -- 600 NF6001-3PB7B NF6003-3PB7B NF6004-3PB7B NF600X-3PB7B NF600P-3PB7B -- 800 NF8001-3PB4A NF8003-3PB4A NF8004-3PB4A NF800X-3PB4A NF800P-3PB4A -- 1200 NF12001-3PB4A NF12003-3PB4A NF12004-3PB4A NF1200X-3PB4A NF1200P-3PB4A -- 1600 NF16001-3P8A NF16003-3P8A NF16004-3P8A NF1600X-3P8A -- -- 2000 NF20001-3P8A NF20003-3P8A NF20004-3P8A NF2000X-3P8A -- -- 3150 1 NF31501-3P8A NF31503-3P8A NF31504-3P8A NF3150X-3P8A -- -- NOTE: 19 All enclosed switches are provided with a black handle; however, most handles can be substituted with a red and yellow handle if desired. EXAMPLE: A red/yellow selector handle for an EOT16U3M1-S can be substituted for the black selector handle by using the "S1" suffix instead of the "S" suffix, new catalog #EOT16U3M1-S1. 1 IEC rated only. 2 New Washdown. 19.45 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h Di witc sed s clo En 6 pole Non-fusible, 16A - 1200A 6 pole, 600V, 16-1200A Pistol handle UL/NEMA Enclosure Type UL general purpose amp rating 1 3R/12 4 4X Stainless 4X Plastic 7 Catalog number Catalog number Catalog number Catalog number Catalog number Catalog number 16 NF161-6PB6C NF163-6PB6C NF164-6PB6A NF16X-6PB6C NF16P-6PB6A NF167-6P 25 NF251-6PB6C NF253-6PB6C NF254-6PB6A NF25X-6PB6C NF25P-6PB6A NF257-6P 40 NF321-6PB6C NF323-6PB6C NF324-6PB6A NF32X-6PB6C NF32P-6PB6A NF327-6P 60 NF451-6PB6B NF453-6PB6B NF454-6PB6B NF45X-6PB6B NF45P-6PB6B NF457-6P 80 NF631-6PB6A NF633-6PB6A NF634-6PB6A NF63X-6PB6A NF63P-6PB6A NF637-6P 30 NF301-6PB6B NF303-6PB6B NF304-6PB6B NF30X-6PB6B NF30P-6PB6B - 60 NF601-6PB6C NF603-6PB6B NF604-6PB6B NF60X-6PB6B NF60P-6PB6B - 100 NF1001-6PB6B NF1003-6PB6B NF1004-6PB6B NF100X-6PB6B NF100P-6PB6B - 125 NF1251-6PB2A NF1253-6PB2A NF1254-6PB4A NF125X-6PB4A NF125P-6PB4A - 200 NF2001-6PB4B NF2003-6PB4B NF2004-6PB4B NF200X-6PB4B NF200P-6PB4B - 400 NF4001-6PB8B NF4003-6PB8B NF4004-6PB8B NF400X-6P8B NF400P-6P8B - 600 NF6001-6PB8B NF6003-6PB8B NF6004-6PB8B NF600X-6P8B NF600P-6P8B - 800 NF8001-6PB8A NF8003-6PB4A NF8004-6PB4A NF800X-6P8A NF800P-6P8A - 1200 NF12001-6P8A NF12003-6PB4A NF12004-6P8A NF1200X-6P8A NF1200P-6P8A - 3 Pole double throw 3 pole, 600V, 16-1200A Pistol handle UL/NEMA Enclosure Type UL general purpose amp rating 16 25 40 60 80 30 60 100 125 200 400 600 800 1200 1 Catalog number NF161-3TB8C NF251-3TB8C NF321-3TB8C NF451-3TB8B NF631-3TB8A NF301-3TB8B NF601-3TB8B NF1001-3TB8B NF1251-3TB8A NF2001-3TB4B NF4001-3TB4B NF6001-3TB4A NF8001-3TB4A NF12001-3TB4A 3R/12 Catalog number NF163-3TB8C NF253-3TB8C NF323-3TB8C NF453-3TB8B NF633-3TB8A NF303-3TB8B NF603-3TB8B NF1003-3TB8B NF1253-3TB8A NF2003-3TB4B NF4003-3TB4B NF6003-3TB4B NF8003-3TB4A NF12003-3TB4A 4 Catalog number NF164-3TB8C NF254-3TB8C NF324-3TB8C NF454-3TB8B NF634-3TB8A NF304-3TB8B NF604-3TB8B NF1004-3TB8B NF1254-3TB8A NF2004-3TB4B NF4004-3TB4B NF6004-3TB4A NF8004-3TB4A NF12004-3TB4A 4X Stainless Catalog number NF16X-3TB8C NF25X-3TB8C NF32X-3TB8C NF45X-3TB8B NF63X-3TB8A NF30X-3TB8B NF60X-3TB8B NF100X-3TB8B NF125X-3TB8A NF200X-3TB4B NF400X-3TB4B NF600X-3TB4A NF800X-3TB4A NF1200X-3TB4A 4X Plastic Catalog number NF16P-3TB8A NF25P-3TB8A NF32P-3TB8A NF45P-3TB8B NF63P-3TB8A NF30P-3TB8B NF60P-3TB8B NF100P-3TB8B NF125P-3TB8A NF200P-3TB4B NF400P-3TB4B NF600P-3TB4A NF800P-3TB4A NF1200P-3TB4A 19 19.46 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con En itch nect clo es se d 3 Pole Fusible, 30A - 800A FJ30X-3PB6B 3 pole, 600V, 30-800A Pistol handle UL/NEMA Enclosure Type UL general purpose amp rating Fuse Type 1 3R/12 4 4X Stainless 4X Plastic Catalog number Catalog number Catalog number Catalog number Catalog number 30 J FJ301-3PB6B FJ303-3PB6B FJ304-3PB6B FJ30X-3PB6B 30 CC FC301-3PB6B FC303-3PB6B FC304-3PB6B FC30X-3PB6B FJ30P-3PB6B FC30P-3PB6B 60 J FJ601-3PB6B FJ603-3PB6B FJ604-3PB8B FJ60X-3PB8B FJ60P-3PB8B 100 J FJ1001-3PB8B FJ1003-3PB8B FJ1004-3PB8B FJ100X-3PB8B FJ100P-3PB8B 200 J FJ2001-3PB8C FJ2003-3PB8C FJ2004-3PB8C FJ200X-3PB8C FJ200P-3PB8C 400 J FJ4001-3PB4C FJ4003-3PB4C FJ4004-3PB4C FJ400X-3PB4C FJ400P-3PB4C 600 J FJ6001-3PB7C FJ6003-3PB7C FJ6004-3PB7C FJ600X-3PB7C FJ600P-3PB7C 800 L FL8001-3PB4B FL8003-3PB4B FL8004-3PB4B FL800X-3PB4B FL800P-3PB4 19 19.47 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h Di witc sed s clo En Accessories Fusible Auxiliary contacts Contact configuration For use on: 1 N.O. + 1 N. C. 30A 2 N.O. + 2 N.C. 60-1200 OA4B1C Catalog number OA4B1C 1 N.O. OA1G10 1 N.C. OA3G01 Accessories For use on: Installation suffix code Description 30A Neutral block N 60A - 100A Neutral block N 200A - 400A Neutral block N 600A - 800A Neutral block N Service entrance, 3 wire U 30A - 200A 400A - 800A Service entrance, 4 wire V Service entrance, 3 wire U Service entrance, 4 wire V OA1G10 Accessories Non -fusible Auxiliary contacts Contact configuration For use on: 16A - 100A 200A - 1200A 1600A - 3150A Catalog number 1 N.O. OA1G10 1 N.C. OA1G01 1 N.O. & 1 N.C. OA2G11 1 N.O. OA1G10 1 N.C. OA3G01 1 N.O. & 1 N.C. OZXK-1 2 N.O. & 2 N.C. OZXK-2 OA1G_ Accessories For use on: 19 Description Installation suffix code EOT16, 32 Neutral or isolated ground block N or G EOT45, 63 Neutral or isolated ground block N or G OT30, 60, 100 Neutral or isolated ground block N or G NF200 - 1200A Neutral block N NF1600 - 3150A Neutral block N NF200 - 1200A Service entrance, 3 wire U NF200 - 1200A Service entrance, 4 wire V OZXK_ 19.48 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nect ch es da nica ta l Technical data Approximate dimensions Selecting switches per NEC Selecting switches per NEC Article 430 of the US National Electric Code includes two methods for properly sizing disconnect switches: 1. Single motor application 2. Combination load application A properly sized disconnect switch for a single motor will: A properly sized disconnect switch for a combination load will be selected by adding all the simultaneous individual loads in the circuit under consideration. a) have an ampere rating greater than or equal to 115 percent of the rated motor full load current; or, b) have a HP rating greater than or equal to the rated motor HP (at applied voltage) if the disconnect switch under consideration is HP rated. Using motor nameplate information, load information, and tables from section 430 of the NEC, determine one equivalent full load current and one equivalent locked rotor current. The equivalent locked rotor current can be used with table 430-151 to determine an equivalent HP rating. Select a disconnect switch: a) greater than or equal to 115 percent of the equivalent full load current; and, b) greater than or equal to the equivalent HP rating. Use of UL98 & UL508 Disconnects According to NEC (R) Article 430 To supply UL98 Feeder Circuit UL98 Motor feeder Non-Fusible Switches OT30, OT60 OT100 OT200, OT400, OT600, OT800, OT1200 OETL-NF1600 thru OETL-NF2000 Motor feeder short circuit and ground fault protection UL98 Fusible Switches OS30, OS60, OS100, OS200, OS400, OS600 OS800, OS1200 Motor disconnecting means (NEC (R) 430.101 - 430.113) Motor branch-circuit short-circuit protection Typical control panel 19 (NEC (R) 430.51 - 430.58) Motor controller Branch Circuit UL508 (NEC (R) 430.81 - 4.30.91) Motor overload protection OL (NEC (R) 430.31 - 4.30.44) OSHA Lockout/tagout disconnect (NEC (R) 430.81 - 430.91) Motor Non-Fusible Switches OT16, OT25, OT40, OT63, OT80 (UL98 switches can also be applied) M 19.49 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage UL508 Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h l Di witc nica s ch Te data Technical data OT16F3 - OT100F3 UL & CSA UL & CSA Catalog number 3 pole Approvals1 2 pole 3 pole 4 pole OT16F3 OT25F3 OT40F3 OT63F3 OT80F3 OT30F3 OT60F3 OT100F3 N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL508 & IEC UL508 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC -40 to 40C General purpose amp rating pf = 0.7 - 0.8 A 20 30 40 60 80 30 60 100 Max. operating voltage V 600 600 600 600 600 600 600 600 Max. horsepower rating/motor FLA current, pf = 0.4 - 0.5 Three phase 240V HP/A 5/15.2 7.5/22.0 10/28.0 15/42.0 20/54.0 10/28.0 20/54.0 30/80.0 480V HP/A 10/14.0 15/21.0 20/27.0 30/40.0 40/52.0 20/27.0 40/52.0 50/65.0 600V HP/A 10/11.0 20/22.0 25/27.0 30/32.0 40/41.0 30/32.0 40/41.0 50/52.0 Single phase 120V HP/A 1/16 1.5/20 3/24 2/24.0 2/24.0 2/24.0 3/34.0 5/56.0 240V HP/A 2/13.2 3/18.7 5/30.8 7.5/40.0 10/57.5 5/28.0 7.5/40.0 15/68.0 Short circuit rating with fuse Fuse type CC kA 10 -- 10 --- 10 --- -- -- -- -- -- -- -- -- -- -- Fuse type J kA 10 10 10 10 10 10 100 -- 100 -- 200 -- 200 -- 200 -- Fuse type T kA 10 10 10 10 10 10 100 -- 100 -- 200 -- 200 -- 200 -- Fuse type RK1 kA 10 -- 10 -- 10 -- -- -- -- -- -- -- -- -- -- -- Fuse type RK5 kA 5 5 5 5 5 5 10 5 10 5 -- -- -- -- -- -- Fuse type L kA -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Fuse type H kA -- -- -- -- -- -- -- 5 -- 5 -- -- -- -- -- -- A 30 60 4 30 60 4 30 60 4 100 150 100 150 60 -- 150 -- 150 -- Maximum fuse size 3 cycle short circuit current withstand rating 5 kA -- -- -- -- -- -- -- -- Endurances Min. Electrical endurance, pf = 0.75 - 0.80 operation cycles 6000 6000 6000 6000 6000 6000 6000 6000 Min. Electrical endurance, pf = 0.40 - 0.50 operation cycles 1000 1000 1000 1000 1000 2 2 2 20,000 20,000 20,000 20,000 20,000 20,000 20,000 20,000 Mechanical endurance operations Physical characteristics Weight, switches Dimension, switches 3 pole lb 0.24 0.24 0.24 0.59 0.59 0.79 0.79 0.79 4 polelb 0.33 0.33 0.33 0.77 0.77 1.10 1.10 1.10 3 pole H in 2.68 2.68 2.68 3.60 3.60 3.94 3.94 3.94 W in 1.38 1.38 1.38 2.07 2.07 2.76 2.76 2.76 D in 2.20 2.20 2.20 2.85 2.85 2.95 2.95 2.95 lb. in. 8.9 8.9 8.9 8.9 8.9 8.9 8.9 8.9 .24 x .24 .24 x .24 .24 x .24 .24 x .24 .24 x .24 .24 x .24 .24 x .24 .24 x .24 6x6 6x6 6x6 6x6 6x6 6x6 6x6 6x6 8.8 8.8 8.8 10.5 10.5 17.5 17.5 17.5 Shaft set screw tightening torque Shaft size -- square Switch operating torque for rotary 3 pole switches in mm lb. in. Not required Terminal lug kits Wire range AWG #18 - 8 Not required Not required Not required Not required Not required Not required Not required #18 - 8 #18 - 8 #14 - 4 #14 - 4 #14 - 4 #14 - 4 #8 - 1/0 Torque: Wire tightening lb. in. 7 7 7 18 18 55 55 55 Lug mounting lb. in. Integral Integral Integral Integral Integral Integral Integral Integral OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ A600 A600 A600 A600 A600 A600 A600 600 Auxiliary contacts 19 NEMA ratings, AC A600 AC rated voltage VAC 600 600 600 600 600 600 600 A 10 10 10 10 10 10 10 10 AC maximum volt-ampere making VA 7200 7200 7200 7200 7200 7200 7200 7200 AC maximum volt-ampere breaking VA 720 AC thermal rated current NEMA ratings, DC R300 DC rated voltage DC thermal rated current DC maximum make-break Torque: Wire tightening Wire range 1 2 3 4 5 VDC 720 720 720 720 720 720 720 R300 R300 R300 R300 R300 R300 R300 300 300 300 300 300 300 300 300 A 1 1 1 1 1 1 1 1 VA 28 28 28 28 28 28 28 28 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 7 #18 - 14 lb. in AWG UL Listed switches are also CSA Approved. UL98 overload test, 50 operations, pf 0.40 - 0.50 at 2x FLA. Multi-tap lug available, please see page 19.34. Fuse size 70A for RK5 When protected by any Listed fuse or Listed circuit breaker whose current rating does not exceed the maximum thermal current rating of the switch. 19.50 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nect ch es da nica ta l Technical data OT200U03 - OETL-NF3150 UL & CSA UL & CSA Catalog number 3 pole OT200U03 Approvals1 2 pole 3 pole 4 pole UL98 & IEC UL98 & IEC UL98 & IEC -40 to 40C General purpose amp rating pf = 0.7 - 0.8 Max. operating voltage OT400U03 OT600U03 OT800U03 OT1200U03 OETL-NF1600 UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC IEC OETL-NF2000 UL98 & IEC UL98 & IEC IEC OETL-NF3150 5 IEC IEC IEC A 200 400 600 800 1200 1600 2000 3150 V 600 600 600 600 600 600 480 -- Max. horsepower rating/Max. motor FLA current, pf = 0.4 - 0.5 Three phase 240V HP/A 75/192.0 125/312.0 200/480.0 200/602 -- -- -- -- 480V HP/A 150/180.0 250/302.0 450/515 500/590 -- -- -- -- 600V HP/A 200/192.0 350/336.0 500/472.0 500/472 -- -- -- -- 120V HP/A -- -- -- -- -- -- -- -- 240V HP/A -- -- -- -- -- -- -- -- Single phase Short circuit rating with fuse Fuse type CC kA -- -- -- -- -- -- -- -- Fuse type J kA 200 100 --/100 -- -- -- -- -- Fuse type T kA -- -- 100/-- -- -- -- -- -- Fuse type RK1 kA -- -- -- -- -- -- -- -- Fuse type RK5 kA -- -- 100 -- -- -- -- -- Fuse type L kA -- -- --/100 100 100 100 100 -- Fuse type H kA -- -- --/100 -- -- -- -- -- Maximum fuse size A 200 600 600/800 1200 1200 2000 2000 -- 14 30 50 50 50 65 65 -- 6000 1000 1000 500 500 500 500 400 2 3 cycle short circuit current withstand rating 6 kA Endurances Min. Electrical endurance, pf = 0.75 - 0.80 operation cycles Min. Electrical endurance, pf = 0.40 - 0.50 operation cycles 2 2 2 2 2 2 2 20,000 10,000 6,000 6,000 6000 6000 6000 3 pole lb 2.9 5.7 11.4 33.5 33.5 127.7 127.7 127.7 4 pole lb 3.5 6.8 14.3 42.9 42.9 149.7 149.7 149.7 3 pole Mechanical endurance operations 20,000 Physical characteristics Weight, switches Dimension, switches H in 6.69 8.66 9.84 14.65 14.65 21.5 21.5 21.5 W in 6.67 8.70 10.48 13.78 13.78 18.11 18.11 18.11 D in Shaft set screw tightening torque Shaft size -- square in 3.27 4.15 5.47 5.20 5.20 10.67 10.67 10.67 lb. in. 14 - 17.7 -- -- -- -- -- -- -- .24 x .24 .47 x .47 .47 x .47 .47 x .47 .47 x .47 .47 x .47 .47 x .47 .47 x .47 6x6 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 Switch operating torque for rotary 3 pole switches mm lb. in. 62 Terminal lug kits OZXA-200 Wire range 12 x 12 142 184 575 575 438 438 438 OZXA-400 OZXA-800 OZXA-1200 OZXA-1200 OZXA-28 OZXA-28/2 OZXA-28/2 (4)#2-600kcmil (4)#2-600kcmil (8)#2-600kcmil (8)#2-600kcmil 375 AWG #4-300kcmil3 #2-600kcmil3 (2)#2-600kcmil3 (4)#2-600kcmil3 Torque: Wire tightening lb. in. 200 375 375 500 500 375 375 Lug mounting lb. in. 72 240 240 450-670 450-670 230 230 230 Auxiliary contacts OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OZXK-_ _ OZXK-_ _ OZXK-_ _ NEMA ratings, AC A600 A600 A600 A600 A600 A600 A600 A600 VAC 600 600 600 600 600 600 600 600 A 10 10 10 10 10 10 10 10 AC maximum volt-ampere making VA 7200 7200 7200 7200 7200 7200 7200 7200 AC maximum volt-ampere breaking VA AC rated voltage AC thermal rated current NEMA ratings, DC DC rated voltage VDC DC thermal rated current DC maximum make-break Torque: Wire tightening Wire range 1 2 3 4 5 6 720 720 720 720 720 720 720 720 P600 P600 P600 P600 P600 P600 P600 P600 600 600 600 600 600 600 600 600 A 5 5 5 5 5 5 5 5 VA 138 138 138 138 138 138 138 138 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 7 #22 - #14 lb. in AWG UL Listed switches are also CSA Approved. UL98 overload test, 50 operations, pf 0.40 - 0.50 at 2x FLA. Multi-tap lug available, please see page 19.34. Fuse size 70A for RK5 IEC rated only. When protected by any Listed fuse or Listed circuit breaker whose current rating does not exceed the maximum thermal current rating of the switch. 19.51 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A 19 ct ne s n o e sc h l Di witc nica s ch Te data Technical data OT16F3 - OT100F3 IEC IEC Catalog number 3 pole Rated insulation and operation voltage, AC20 and DC20 Rated impulse withstand voltage OT16F3 OT25F3 OT40F3 OT63F3 V 750 750 750 750 kV 8 8 8 8 OT80F3 OT30F3 OT60F3 OT100F3 750 750 750 750 8 8 8 8 40C Rated thermal current, Ith AC 20/DC 20 open 1 A 25 32 40 63 80 40 63 115 40C enclosed A 25 32 40 63 80 40 63 115 60C enclosed A 25 32 40 63 80 40 63 115 AC 21A 500V A 16 25 40 63 80 30 60 100 690V A 16 25 40 63 80 40 63 100 1000V A -- -- -- -- -- -- -- -- AC 22A 500V A 16 25 40 63 80 40 63 100 690V 100 Rated operational currents A 16 25 40 63 80 40 63 1000V A -- -- -- -- -- -- -- -- AC 23A 415V A 16 20 23 45 75 40 63 80 500V A 16 20 23 45 58 40 60 60 690V A 10 11 12 20 20 40 40 40 1000V A -- -- -- -- -- -- -- -- Rated operational currents/poles in series DC21A 48V A 16/1 25/1 32/1 45/1 63/1 40/1 63/1 100/1 110V A 16/2 25/2 32/2 45/2 63/2 40/2 63/2 100/2 220V A 16/3 25/3 32/3 45/4 63/4 40/4 63/4 100/4 440V A 16/4 25/6 32/6 3 3 3 3 3 750V A 16/8 25/8 32/8 3 3 3 3 3 DC22A 48V A 16/1 25/1 32/1 45/1 63/1 40/1 63/1 100/1 110V A 16/2 25/2 32/2 45/2 63/2 40/2 63/2 100/2 220V A 16/3 25/3 32/4 45/4 63/4 40/4 63/4 63/4 440V A 16/6 25/8 3 3 3 3 3 3 750V A 16/8 25/8 3 3 3 3 3 3 DC23A 48V A 16/1 25/1 32/1 45/1 63/1 40/1 63/1 100/1 110V A 16/2 25/2 32/2 45/2 63/2 40/2 63/2 100/2 220V A 16/4 25/4 32/4 45/4 63/4 40/4 63/4 63/4 440V A 10/4 3 3 3 3 3 3 3 750V A 16/8 3 3 3 3 3 3 3 Rated operational power AC23A 230V kW 3 4 5.5 11 22 7.5 11 22 400/415V kW 7.5 9 11 22 37 15 18.5 37 500V kW 7.5 9 11 22 37 15 18.5 37 690V kW 7.5 9 11 15 18.5 15 15 37 kA 50 50 50 50 50 50 50 50 A 25 32 40 63 80 100 100 100 Short-circuit current with back-up fuses of size 19 Load Load Load 2 poles in series 3 poles in series 4 poles in series 1 The ambient air temperature does not exceed +40C and its average over a period of 24 hours does not exceed +35C according to IEC 947. 2 IEC 947-3, utilization category B, infrequent operation. 3 Not available at time of printing, please consult factory. 19.52 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nect ch es da nica ta l Technical data OT200U03 - OETL-NF3150 IEC IEC Catalog number 3 pole Rated insulation and operational OT200U03 OT400U03 OT600U03 OT800U03 OT1200U03 OETL-NF1600 OETL-NF2000 OETL-NF3150 V 1000 1000 1000 1000 1000 1000 1000 1000 kV 12 12 12 8 8 8 8 8 40C voltage, AC20 and DC20 Rated impulse withstand voltage Rated thermal current, Ith AC 20/DC 20 open1 A 250 400 800 1600 1600 2500 3150 40C enclosed A 250 400 800 1600 1600 2300 2300 2600 60C enclosed A -- -- -- -- -- 1950 1950 2300 Rated operational currents AC 21A 500V A 250 400 800 1600 1600 25002 25002 31502 690V A 250 400 800 1600 1600 25002 25002 31502 1000V A -- -- 800 16001600 -- -- -- AC 22A 500V A 250 400 800 1600 1600 16002 16002 16002 690V -- A 250 400 800 1600 1600 -- -- 1000V A -- -- 800 -- -- -- -- -- AC 23A 415V A 250 400 800 1250 1250 8002 8002 8002 500V A 250 400 800 1250 1250 8002 8002 8002 690V A 250 400 800 1250 1250 -- -- -- A -- -- 800 -- -- -- -- -- 1000V Rated operational currents/poles in series DC21A 48V A 250/1 630/2 800/2 -- -- 2500/2 2500/2 3150/2 110V A 250/2 630/2 800/2 -- -- 2500/2 2500/2 3150/2 220V A 250/2 630/2 800/2 -- -- 2500/2 2500/2 3150/2 440V A 250/3 630/3 800/3 -- -- 2500/3 2500/3 3150/2 750V A 250/4 -- -- -- -- -- -- -- DC22A A 250/1 630/2 800/2 -- -- 2500/2 2500/2 3150/2 48V 110V A 250/2 630/2 800/2 -- -- 2500/2 2500/2 3150/2 220V A 250/2 630/2 800/2 -- -- 2500/2 2500/2 3150/2 440V A 250/3 630/3 800/3 -- -- -- -- -- 750V A 250/4 -- -- -- -- -- -- -- DC23A48V A 250/1 630/2 -- -- -- -- -- -- 110V A 250/2 630/2 -- -- -- -- -- -- 220V A 250/2 630/2 -- -- -- -- -- -- 440V A 250/3 -- -- -- -- -- -- -- 750V A 250/4 -- -- -- -- -- -- -- Rated operational power AC23A 230V kW 75 110 -- -- -- 250 250 250 400/415V kW 132/140 220/230 450 710 710 400 400 400 500V kW 170 280 560 900 900 450 450 450 kW 240 355 800 1200 1200 -- -- -- Short-circuit current kA 100 100 100 50/504 50/504 50/634 50/634 50/634 with back-up fuses of size A 400 800 800 -- -- -- -- -- 690V 19 Load Load Load 2 poles in series 3 poles in series 4 poles in series 1 The ambient air temperature does not exceed +40C and its average over a period of 24 hours does not exceed +35C according to IEC 947. 2 IEC 947-3, utilization category B, infrequent operation. 3 Not available at time of printing, please consult factory. 4 690V / 500V 19.53 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h l Di witc nica s ch Te data Technical data OT16F3 - OT100F3 IEC IEC Catalog number 3 pole Rated short-circuit making capacity, prospective peak value, Icm OT16F3 OT25F3 0.7 0.7 kA OT40F3 OT63F3 OT80F3 OT30F3 0.7 1.4 1.4 3.6 OT60F3 3.6 OT100F3 3.6 Rated short time withstand current, RMS lcw 0.2skA -- -- -- -- -- -- -- -- RMS lcw 0.5 0.5 0.5 1 1 2.5 2.5 2.5 1.0s kA AC breaking capacity A 128 160 184 240 304 320 504 640 pf = 0.35 500VA 415V 128 160 184 240 256 320 480 480 690V A 80 88 96 160 160 320 320 320 DC breaking capacity/poles in series L/R = 15ms 48V A 64/1 100/1 128/1 180/1 252/1 160/1 252/1 400/1 110V A 64/2 100/2 128/2 180/2 252/2 160/2 252/2 400/2 220V A 64/3 100/4 128/4 180/4 180/4 160/4 252/4 252/4 440V A 1 1 1 1 1 1 1 1 750V A 1 1 1 1 1 1 1 1 Physical characteristics Electrical endurance at rated operational current, pf = 0.65 operation cycles Mechanical endurance operations 3000 3000 3000 3000 3000 3000 3000 3000 20,000 20,000 20,000 20,000 20,000 20,000 20,000 20,000 Weight 3 pole kg 0.11 0.11 0.11 0.27 0.27 0.36 0.36 0.36 4 pole kg 0.15 0.15 0.15 0.35 0.35 0.5 0.5 0.5 Dimension 3 pole H mm 68 68 68 91.5 91.5 100 100 100 W mm 35 35 35 52.5 52.5 70 70 70 D mm 56 56 56 72.5 72.5 75 75 75 Power loss per pole W mm Shaft size -- square 0.3 0.6 1 1.4 2.8 1 1.6 4 6x6 6x6 6x6 6x6 6x6 6x6 6x6 6x6 Switch operating torque for rotary 3 pole switches Suitable conductor cross section Cu Nm mm2 1 1 1 1.2 1.2 2 2 2 0.75 - 10 0.75 - 10 0.75 - 10 1.5 - 25 1.5 - 25 1.5 - 25 1.5 - 25 10 - 70 Bolt size -- Auxiliary contacts Ratings according to IEC 947-5-1 Rated voltage, Ui -- -- OA1G_ _ OA1G_ _ OA1G_ _ OA1G_ _ -- OA1G_ _ -- OA1G_ _ -- OA1G_ _ -- OA1G_ _ -- VAC 690 690 690 690 690 690 690 690 Thermal current, Ith AC12/DC12 Ie, A Ue =120V A 16 16 16 16 16 16 16 16 A -- -- -- -- -- -- -- -- 125V A -- -- -- -- -- -- -- -- 240V A 62 62 62 62 62 62 62 62 250V A -- -- -- -- -- -- -- -- 400V A 42 42 42 42 42 42 42 42 415V A -- -- -- -- -- -- -- -- 440V A -- -- -- -- -- -- -- -- 480V A -- -- -- -- -- -- -- -- 500V A -- -- -- -- -- -- -- -- 600V A -- -- -- -- -- -- -- -- 690V A 22 22 22 22 22 22 22 22 19 Load Load Load 2 poles in series 3 poles in series 4 poles in series 1 Not available at time of printing, please consult factory. 2 AC15, according to IEC947-5-1. 19.54 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nect ch es da nica ta l Technical data OT200U03 - OETL-NF3150 IEC IEC Catalog number 3 pole OT200U03 OT400U03 OT600U03 OT800U03 OT1200U03 OETL-NF1600 OETL-NF2000 110 110 140/105 140/105 OETL-NF3150 Rated short-circuit making capacity, prospective peak value, Icm500/690V kA 30 65 80 140/105 Rated short time withstand current, RMS lcw 0.25s, 690V kA 15 28 36 50 50 -- -- -- RMS lcw 1.0s, 690V kA 8 15 20 50 2 50 2 80 2 80 2 80 2 AC breaking capacity 415V A 2000 3200 5760 10,000 10,000 6400 6400 6400 pf = 0.35 500V A 2000 3200 5600 10,000 10,000 6400 6400 6400 690V A 2000 3200 5600 10,000 3 10,000 3 4800 4 4800 4 4800 4 DC breaking capacity/poles in series L/R = 15ms, 3 pole in series 48V A 1000/2 1 1 1 1 1 1 110V A 1000/2 1 1 1 1 1 1 1 220V A 1000/2 1600/2 2000/2 - - 2600/2 2600/2 2600/2 440V A 1000/3 1600 2000/3 1 1 1 1 1 750V A 1000/4 1 1 1 1 1 1 1 1 Physical characteristics Electrical endurance at rated operational current, pf = 0.65 operation cycles Mechanical endurance operations 1000 1000 1000 500 500 100 5 100 5 100 5 20,000 16,000 10,000 6000 6000 6000 6000 6000 Weight 3 pole kg 1.2 2.2 5.2 15.2 15.2 37 37 37 4 pole kg 1.6 2.6 6.5 19.5 19.5 47 47 47 Dimension 3 pole H mm 162 216 250 372 372 372 546 546 W mm 219 260 266 350 350 468 468 468 D mm 92.5 130 139 132 132 271 271 271 Power loss per one pole W mm 6.5 10 40 29 48 90 90 140 6x6 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 12 x 12 rotary 3 pole switches Nm 7 16 21 21 21 50 50 50 Suitable conductor cross section Cu -- -- -- -- -- -- -- -- Bolt size 8 x 25 10 x 30 12 x 40 12 x 60 12 x 60 12 x 60 12 x 60 12 x 60 Auxiliary contacts OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OZXK-_ _ OZXK-_ _ OZXK-_ _ 690 Shaft size -- square Switch operating torque for mm2 Ratings according to IEC 947-5-1 Rated voltage, Ui VAC 690 690 690 690 690 690 690 Thermal rated current, Ith A 16 16 10 10 10 10 10 10 AC12/DC12 Ie, A Ue = 120V A -- -- 8/-- 8/-- 8/-- 8/-- 8/-- 8/-- --/1.1 125V A -- -- --/1.1 --/1.1 --/1.1 --/1.1 --/1.1 240V A 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- 6/-- A -- -- --/0.55 --/0.55 --/0.55 --/0.55 --/0.55 --/0.55 250V 400V A 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- 415V A -- -- 4/-- 4/-- 4/-- 4/-- 4/-- 4/-- --/0.31 440V A -- -- --/0.31 --/0.31 --/0.31 --/0.31 --/0.31 480V A -- -- 3/-- 3/-- 3/-- 3/-- 3/-- 3/-- 500V A -- -- 3/0.27 3/0.27 3/0.27 3/0.27 3/0.27 3/0.27 600V A -- -- --/0.2 --/0.2 --/0.2 --/0.2 --/0. 2--/0.2 690V A 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- 2/-- 19 1 2 3 4 5 Load Load Load 2 poles in series 3 poles in series 4 poles in series Not available at time of printing, please consult factory. Maximum distance between busbar support and switch terminal 70mm. pf 0.95. pf 0.65. IEC 947-3, utilization category B, infrequent operation. 19.55 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h l Di witc nica s ch Te data Technical data OTDC Disconnect switches 100A - 200A, 1000VDC Technical data in accordance to UL98B for disconnect switches OTDC100 and OTDC200 Suitable for use in photovoltaic systems in accordance with Article 690 of NEC Catalog number Approvals OTDC100 OTDC180 OTDC200 UL98B & IEC UL98B & IEC UL98B & IEC General purpose amp rating (-20 - +50 C) A 100 180 200 Maximum operating voltage V 1000 1000 1000 Short circuit current rating at 1000 VDC kA SCCR with: 5 5 5 Circuit breaker Circuit breaker Circuit breaker Endurances Oper 4000 4000 4000 Wiring range MCM #4-300 #4-300 #4-300 19 19.56 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nect ch es da nica ta l Technical data OS30FA_12 - OS1200L03 UL & CSA UL & CSA Catalog number 3 pole Approvals 1 2 pole 3 pole 4 pole Technical ratings OS30FA_12 OS60GJ12 OS100GJ03 OS200J03 OS400J03 OS600J03 OS800L03 0S1200U03 N/A UL98 & IEC UL98 & IEC N/A UL98 & IEC UL98 & IEC IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC UL98 & IEC A 30 60 100 200 400 600 800 1200 V 600 600 600 600 600 600 600 600 250/602.0 500/590.0 500/472.0 -- -- -- -40 to 40C General purpose amp rating pf = 0.7 - 0.8 Max operating voltage Max horsepower rating/ Max motor FLA current pf = 0.4 - 0.5 Three phase 240V HP/A 480V HP/A 600V HP/A Single phase 120V 240V 7.5/22.0 15/42.0 30/80.0 60/145.0 125/312.0 200/480.0 15/21.0 30/40.0 60/77.0 125/156.0 250/302.0 400/477.0 20/22.0 50/52.0 75/77.0 150/144.0 350/336.0 500/472.0 HP/A HP/A 2/24.0 3/17.0 -- -- -- -- -- -- -- -- -- -- -- -- -- -- Short circuit rating with fuse kA UL Fuse size A UL Fuse type 200 30 J/CC 200 60 J 200 100 J/T 200 200 J/T 200 400 J 200 600 J 200 800 L 200 1200 L Endurances Min. Electrical endurance, pf = 0.75 - 0.80 operation cycles 6000 6000 6000 6000 1000 1000 500 500 Mechanical endurance operation 20,000 20,000 20,000 16,000 12,000 4,000 3000 2000 3 pole lb 4 pole lb 1.54 1.98 2.86 3.52 3.30 3.96 5.9 7.5 12.56 15.21 28.66 37.48 28.66 37.48 63.93 - 3.66 4.15 4.10 3.94 5.63 5.04 5.67 7.07 5.10 6.5 7.1 5.2 9.29 10.04 6.93 12.04 13.50 9.17 12.04 13.50 9.17 16.7 16.42 11.62 .24 x .24 6x6 .24 x .24 6x6 .24 x .24 6x6 .24 x .24 6x6 .47 x .47 12 x 12 .47 x .47 12 x 12 .47 x .47 12 x 12 .47 x .47 12 x 12 26.6 35.5 70.9 195 195 336 336 575 Physical characteristics Weight Dimension 3 pole H in W in D in Shaft size square Switch operating torque for rotary 3 pole switches in mm lb. in. Terminal lug kits Integral Integral Wire range Torque: Wire tightening Lug mounting OZXA-24 OZXA-200 OZXA-400 OZXA-800 OZXA-800 OZXA-1200 AWG #18 - 8 #14 - 4 #14 - 2/0 #4 - 300kcmil #2 - 600kcmil (2) #2 - 600 kcmil (2) #2 - 600 kcmil (4)#2-600kcmil lb. in. lb. in. 17 N/A 30 N/A 120 50 200 72 500 480 500 480 500 480 500 480 Auxiliary contacts OA4G_ OA1/3G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ OA_G_ NEMA ratings, AC AC rated voltage VAC AC thermal rated current A VA AC maximum volt ampere making VA AC maximum volt ampere breaking -- 250 6 -- -- A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 A600 600 10 7200 720 NEMA ratings, DC DC rated voltage VDC DC thermal rated current A DC maximum make break current A -- -- -- -- P300 300 1 28 R300 300 1 28 R300 300 1 28 R300 300 1 28 P600 600 1 28 P600 600 1 28 P600 600 1 28 P600 600 1 28 Torque: Wire tightening lb. in. 7 7 7 7 7 7 7 7 Wire range AWG #22 - 14/#18 - 14 #18 - 14 #18 - 14 #18 - 14 #18 - 14 #18 - 14 #20 - 12 #20 - 12 19 1 The following UL Listed switches are also CSA approved. 19.57 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h l Di witc nica s ch Te data Technical data OS30FA_12 - OS1200L03 IEC IEC Catalog number 3 pole Technical ratings OS60GJ12 OS100GJ03 OS200J03 OS400J03 OS600J03 OS800L03 OS1200L03 -40 to 40C Rated insulation voltage Pollution degree 3 6 Dielectric strength OS30FA_12 V 50Hz/60Hz, 1 min kV Rated impulse withstand voltage kV 1000 1000 1000 1000 1000 1000 1000 1000 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 32/3.5 32/3.5 32 63/7.5 63/7.5 - 160/12 160/12 - 200/17 200/15 - 400/45 400/30 - 630/60 570/50 - 800/65 720/55 - 1250/110 1000/85 - Rated thermal current, Ith/ max. fuse power dissipation 1 AC 20/DC 20 open 2 40C enclosed Enclosed with solid links A/W A/W A/W with minimum cable cross section Cu mm2 Rated operational voltage AC 20 and DC 20V 6 16 70 95 240 2 x 185 2 x 240 1250/2 x 400 1000 1000 1000 1000 1000 1000 1000 1000 AC Rated operational currents AC 21A 500V 690V A A 32 32 63 63 160 160 200 200 400 630 400630 800 800 1250 Cat. B 1250 Cat. B AC 22A 500V 690V A A 32 32 63 63 160 160 200 200 400 400 630 630 800 800 1250 Cat. B 1250 Cat. B AC 23A 500V A 690V A DC Rated operational currents/poles in series 32 32 63 5 63 5 160 5 160 5 200400 200 400 630 630 800 800 1000 Cat. B 1000 Cat. B DC21A 48V 110V 220V 440V 750V 880V A 32/2 3 A 32/2 A 32/2 A 32/4 A -- A-- 63/2 63/2 63/2 50/4 4 4 160/2 125/2 125/2 125/4 4 4 200/1 200/1 200/1 200/2 180/4 180/4 400/2 400/2 400/2 400/3 CAT. B 400/4 CAT. B - 630/1 CAT. B 630/1 CAT. B 630/1 CAT. B 630/2 CAT. B 630/4 CAT. B 630/4 CAT. B 800/1 CAT. B 800/1 CAT. B 800/1 CAT. B 800/2 CAT. B 720/4 CAT. B 720/4 CAT. B - - - - - - DC22A 48V 110V 220V 440V 750V 880V A 32/2 3 A 32/2 A 32/2 A 32/4 A -- A-- 63/2 63/2 63/2 - 4 4 160/2 125/2 125/2 - 4 4 200/1 200/1 200/1 200/2 180/4 180/4 400/2 400/2 400/2 400/3 CAT. B 400/4 CAT. B - -- -- -- -- -- -- 800/1 CAT. B 800/1 CAT. B 800/1 CAT. B 800/2 CAT. B 800/4 CAT. B 800/4 CAT. B - - - - - - DC23A 48V 110V 220V 440V 750V 880V A A A A A A 32/2 3 32/2 32/2 32/4 -- -- 63/2 63/2 63/2 - - - 160/2 125/2 125/2 - - - 200/1 200/1 200/1 200/2 180/4 180/4 400/2 400/2 400/2 400/3 CAT B 400/4 CAT. B -- -- -- -- -- -- -- 800/1 CAT. B 800/1 CAT. B 800/1 CAT. B 800/2 CAT. B 720/4 CAT. B 720/4 CAT. B - - - - - - Rated operational power 230V 400V 415V 500V 690V AC23A kW kW kW kW kW 7.5 15 15 18.5 22 18.5 30 30 37 55 45 75 75 90 132 60 110 110 132 200 132 220 230 280 400 200 355 355 450 630 250 450 450 560 710 19 1 2 3 4 5 6 Load Load Load Load 2 poles in series 3 poles in series 4 poles in series 2 + 2 parallel contacts in series 315 560 560 710 1000 Ambient temperature 60C: derating 20 percent. Mounting on ceiling: derating 10 percent. Mounting on wall, horizontal fuses: derating 8 percent. The ambient air temperature does not exceed +40C and its average over a period of 24h does not exceed +35C according to IEC 947. For 30A switches, use 2 + 2 parallel contacts in series. Available on request. IEC 947-3, utilization category B, infrequent operation. Pollution degree 3: Conductive pollution occurs, or dry, non-conductive pollution occurs, which becomes conductive due to condensation. 19.58 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nect ch es da nica ta l Technical data OS30FA_12 - OS1200L03 IEC IEC Catalog number 3 pole OS30FA_12 OS60GJ12 OS100GJ03 OS200J03 OS400J03 OS600J03 OS800L03 OS1200L03 504 504 1280 1280 1600 1600 3200 3200 5760 5760 5760 5760 8000 8000 252/2 -- -- -- 640/2 -- -- -- -- -- -- -- -- -- -- -- - - - - - - - - - - - - 13.5 12.5 9.5 2.5 22 22 15 5 35 37.5 - 8 40 40 - 14 75 75 - 18 75 75 - 18 89 105 - 40 15 15 25 30 32 50 60 65 100 90 100 160 180 200 325 250 270 450 310 340 550 440 460 750 2 20,000 4 20,000 9 20,000 8 20,000 30 16,000 46 10,000 75 10,000 75 6000 kg kg 0.7 0.9 1.1 1.3 1.5 1.8 2.6 - 5.7 - 11.5 - 11.5 - 29.00 - Dimension 3 pole H mm W mm D mm 93 106 104 100 143 120 144 179 129 198.5 181.5 132 236 255 176 306 343 233 282 376 233 424.18 417.07 295.14 6x6 6x6 6x6 6x6 12 x 12 12 x 12 12 x 12 12 x 12 Built-in terminal size mm Terminal bolt size, metric thread diameter x length mm -- Terminal bolt tightening torque Nm Fuse-links bolts tightening torque Nm 0.5 - 10 2.5 - 25 -- -- -- -- -- -- -- 2 2 -- 3.5 3.5 M8 x 25 15-22 M5:3.5 M8:5 M8 x 25 15 - 22 4 M10 x 30 30 - 44 20 Operating torque Nm 3 Rated breaking capacity in category AC-23A 500V A 690V A 256 256 Rated breaking capacity/poles in series in category DC-23 <220V A 128/2 440V A 128/4 500 - 750V A -- 1000V A -- Rated conditional short-circuit current r.m.s. 3 80 kA, 415V kA 9 100 kA, 500 V kA 8 50 kA, 690 V kA 7 Rated short time withstand current, 1s. kA 1 Rated capacitor power The capacitor rating of the fusible disconnect switch is limited by the fuse link 400 V kVar 415V kVar 690V kVar Power loss/pole with rated current, without fuse Mechanical endurance W operations Physical characteristics Weight 3 pole 4 pole Shaft size square mm Terminals 2 Auxiliary contacts OA4G_ OA1/3G 1 2 Ratings according to IEC 947-5-1 VAC 690 690 Rated voltage, Ui A 10 16 Thermal current, Ith Ue=24V A --/6 -- AC12 / DC12, Ie 120V A --/6 -- 125V A -- -- 230V A -- 6/-- 250V A 3 / 0.1 -- 400V A -- 4/-- 415V A -- -- 440V A 2/-- -- 480V A -- -- 500V A -- -- 600V A -- -- 690V A -- 2/-- M12 x 40 M12 x 40 50 - 75 50 - 75 M10:30 M12:40 M10:30 M12:40 M12 x 40 50 - 75 M12:40 5 7 7 19 38 38 65 OA_G_ 2 OA_G_ 2 OA_G_ 2 OA_G_ OA_G_ OA_G_ OA_G 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 690 16 -- -- -- -- -- -- -- -- -- -- -- 2/-- 690 16 -- -- -- -- -- -- -- -- -- -- -- 2/-- 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 690 16 -- -- -- 6/-- -- 4/-- -- -- -- -- -- 2/-- 19 1 AC15 / DC12, according to IEC 947-5-1 2 AC15, according to IEC 947-5-1 3 Values shown are corresponding max. allowed cut-off current, peak-values per single phase fuse tests. 19.59 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h l Di witc nica s ch Te data Auxiliary contact timing diagrams OT16 - OT100 Legend 0 30 60 90 ON Main contacts N.O. auxiliary contact OFF O OFF I ON N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position Contacts closing Contacts opening 1 Main contacts close 2 N.O. auxiliary contacts close 3 N.C. auxiliary contacts open 4 Main contacts open 5 N.O. auxiliary contacts open 6 N.C. auxiliary contacts close 0 OT16, OT25, OT40 Catalog number OT16, OT25, OT40 30 60 90 Main contacts Auxiliary contact Contact configuration OA1G10 N.O. auxiliary contact OA1G10 OA1G01 OA2G11 1 N.O. 1 N.C. 1 N.O. & 1 N.C. OA1G01 N.C. auxiliary contact OA2G11 N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position 0 30 60 90 Main contacts OT63, OT80 Catalog number OT63, OT80 OA1G10 N.O. auxiliary contact Auxiliary contact Contact configuration OA1G10 OA1G01 OA2G11 1 N.O. 1 N.C. 1 N.O. & 1 N.C. OA1G01 N.C. auxiliary contact OA2G11 N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position 19 0 Catalog number 60 90 Main contacts OT30, OT60, OT100 OT30, OT60, OT100 30 OA1G10 N.O. auxiliary contact Auxiliary contact Contact configuration OA1G10 OA1G01 OA2G11 1 N.O. 1 N.C. 1 N.O. & 1 N.C. OA1G01 N.C. auxiliary contact OA2G11 N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position 19.60 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nect ch es da nica ta l Auxiliary contact timing diagrams OT200U - OETL-NF3150 OT200U03 - OT1200U03 Catalog number Auxiliary contact Contact configuration OT200U03 - OA1G10 OT1200U03 OA3G01 1 N.O. 1 N.C. 1) OT800 - 1200 only 0 OETL-NF1600 - OETL-NF3150 Catalog number Auxiliary contact Contact configuration OZXK-1 OZXK-2 OZXK-3 1 N.O. & 1 N.C. 2 N.O. & 2 N.C. 4 N.O. & 4 N.C. OETL-NF1600A - OETL-NF3150 30 60 90 Main contacts N.O. auxiliary contact N.C. auxiliary contact OFF 0 ON I = Contacts in closed position = Contacts in closed position OZXK-1 OZXK-2 OZXK-3 19.61 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 19 Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h l Di witc nica s ch Te data Auxiliary contact timing diagrams OS30_ 0 30 60 0 I 0 I 4 Main contacts N.O. auxiliary contact 3 N.C. auxiliary contact ON 90 a I ON 1 OFF 2 O OFF Legend 5 6 OFF 0 ON I = Contacts in closed position = Contacts in closed position Contacts closing 1 Main contacts close 2 N.O. auxiliary contacts close 3 N.C. auxiliary contacts open Contacts opening 4 Main contacts open 5 N.O. auxiliary contacts open 6 N.C. auxiliary contacts close OS30_ Catalog number OS30_ -45 Auxiliary contact OA4B1C OA1G10 OA3G01 Contact configuration 1 N.O. & 1 N.C. 1 N.O. 1 N.C. 0 30 60 90 a Main contacts OA4B1C N.O. auxiliary contact OA4B1C N.C. auxiliary contact OA1G10 N.O. auxiliary contact OA3G01 N.C. auxiliary contact Test 19 19.62 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Auxiliary contact timing diagrams OS60 - OS1200 Di s sw con Te itch nect ch es da nica ta l OS60-OS1200 1) OS1200 only 19 19.63 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h l Di witc nica s ch Te data NEMA Environmental ratings Introduction An enclosure is a surrounding case constructed to provide a degree of protection to personnel against accidental contact with the enclosed equipment and to provide a degree of protection to the enclosed equipment against specified environmental conditions. A brief description of the more common types of enclosures used by the electrical industry relating to their environmental capabilities follows. Refer to NEMA Standards Publication for more information regarding applications, features and design tests. Individual NEMA product Standards Publications or third party certification standards may contain additional requirements for product testing and performance. Definitions pertaining to nonhazardous locations Type 1 Enclosures are intended for indoor use primarily to provide a degree of protection against limited amounts of falling dirt. (NEMA Standard 7-15-1991.) Type 3R Enclosures are intended for outdoor use primarily to provide a degree of protection against rain, sleet and damage from external ice formation. (NEMA Standard 7-15-1991.) Definitions pertaining to hazardous locations Type 4X Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. (NEMA Standard 1-10-1979) Type 7 Enclosures are intended for indoor use in locations classified as Class I, Groups, A, B, C, or D, as defined in the National Electrical Code. (NEMA Standard 7-15-1991.) Type 12 Enclosures are intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping noncorrosive liquids. (NEMA Standard 7-15-1991.) Type 9 Enclosures are intended for indoor use in locations classified as Class II, Groups E, F, or G, as defined in the National Electrical Code. (NEMA Standard 7-15-1991.) Legend - Indoors Type 4 19 Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. (NEMA Standard 1-10-1979.) Type 13 - Water - Dirt/dust X 19.64 1SXU000023C0202 Rev. A - Outdoors Enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil and noncorrosive coolant. (NEMA Standard 1-10-1979.) - Corrosion Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Te itch nect ch es da nica ta l IEC Environmental ratings IP ratings indicate the degree of protection against dust, liquids and impacts. The IP degrees of protection are defined by the French standard NFC 20-010. To rate a device's degrees of protection, the letters IP are followed by up to three numbers. These numbers are defined as follows: first number second number protection against solid objects no protection protected against solid objects over 50mm (e.g. accidental touch by hands.) 1 protected against solid objects over 12 mm (e.g. fingers) IP 0 1 2 protected against solid objects over 2.5 mm (tools & wires) 3 4 5 6 protection against liquids protected against solid objects over 1mm (small tools & small wires) protected against dust (no harmful deposit) totally protected against dust no protection impact 0,225 joule 150g falling from 15 cm 2 impact 0,375 joule 250g falling from15 cm impact 0,50 joule 250g falling from 20cm no protection protected against vertically falling rain or condensation 1 2 protected against direct sprays of water up to 15 from vertical 3 protected against sprays to 60 from vertical 3 protected against water sprayed from all directions protected against low pressure jets of water from all directions protected from strong jets of IP 0 4 5 water (e.g. for use on ship 6 decks) 7 IP 0 impact 2,00 joule 500g falling from 40 cm 5 impact 6,00 joule 1.5kg falling from 40 cm impact 20,00 joule 5 kg falling from 40 cm 7 9 19 protected against the effects of immersion between 15cm and 1m 19.65 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage third number protection against mechanical impacts Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o e sc h l Di witc nica s ch Te data Definitions AC - Alternating current -- Current that reverses its direction of flow twice per cycle. Ambient temperature -- Temperature of the air surrounding the unit. Amp rating -- The basic unit of measurement for electric current (columbs / seconds). Conventional thermal current Ith -- Value of the current the disconnect switch can withstand with poles in closed position, in free air for an eight hour duty, without the temperature rise of its various parts exceeding the limits specified by the standards. Cycle duration -- Total time of the on-load + off-load period. DC - Direct current -- Current that flows in only one direction. Electrical endurance -- Number of on-load operating cycles. IEC environmental protection type -- see page 19.48. Full load amp current FLA -- The current required by a motor to produce full-load torque at the motor's rated speed. Inductive load -- An electrical load characterized by having significant inrush (5 to 6 times FLA for typical design-B AC induction motors). kW -- Kilowatts (1000 watts) Lockout/Tagout -- Means of removing power from electrical equipment during inspection, service or repair. Make / Break -- ON / OFF Mechanical endurance -- Number of off-load operating cycles. Poles in series -- Means of connection poles using wires or bus bars to increase breaking capacity of load. Power factor -- The relationship between working power and total power consumed. Power factor measures how effectively electrical power is being used. Rated insulation Ui -- Voltage value which designates the unit and to which dielectric tests, clearance and creepage distances are referred. manufacturer and taking into account the rated operating voltage Ue, the rated frequency, the rated duty, the utilization category, the electrical contact life and the type of protective enclosure. Rated operating voltage Ue -- Voltage value to which utilization characteristics of the disconnect switch are referred, i.e. phase-tophase voltage in 3 phase circuits. Rated short circuit making capacity Icm-- The rated shortcircuit making capacity of a disconnect switch, a disconnector or a switch-disconnector is the value assigned to equipment at the rated operational voltage, frequency (if any) and specified powerfactor for AC or time constant for DC. It is expressed as the maximum prospective peak current under prescribed conditions. Rated short time withstand current Icw -- The rated shorttime withstand current of a disconnect switch, a disconnector or a switch-disconnector is the value that the equipment can carry without damage, under the test conditions specified in the relevant product standard. The value of the rated short-time withstand current shall be not less than twelve times the maximum rated operational current unless otherwise stated by manufacturer and the duration of the current shall be 1 s. Resistive load -- An electrical load characterized by not having any significant inrush current. Short circuit protection coordination -- Co-ordination types "1" and "2" are defined in IEC 947-4-1. Type 1 coordination -- There has to be no discharge of parts beyond the enclosure. Damage to the contactor and the overload is acceptable. Type 2 coordination -- No damage to the overload relay or other parts has occurred, except that welding of contactor or starter contacts is permitted, if they are easily separated. Time constant -- Ratio of inductance to the resistance: L/R = mH/Ohm = ms. Torque -- The force that produces rotation. It is commonly measured in pound-feet (lb-ft). Torque applies to such things as motor operations, handle rotations, wire tightening. NEMA environmental protection type -- see page 19.47. Volt -- The unit of electrical potential difference and electromotive force. Rated operating current Ie --Current value stated by the 19 19.66 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 00.00 Inches 00.00 [Millimeters] Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OT16F3 - OT100F3 Base & DIN rail mounted switches OT16F3, OT25F3, OT40F3 -- base & DIN rail mounted switch 0.43 0.43 0.18 DIA. 11 4.5 0.24 0.20 56 11 0.47 12 1.38 2.36 2.13 35 60 54 2.68 68 0.87 1.77 22 0.43 1.38 11 45 0.51 35 13 2.20 56 OT63F3, OT80F3 -- base & DIN rail mounted switch 0.69 0.18 DIA. 0.69 17.5 OT16,25,32 17.5 0.24 0.20 56 4.5 0.59 15 3.60 3.25 2.85 1.38 91.5 82.5 72.5 35 2.47 1.71 63 43.5 0.43 2.89 2.07 11 52.5 73.5 0.69 17.5 OT30F3, OT60F3, OT100F3 -- base & DIN rail mounted switch 0.18 DIA. 4.5 0.88 OT45,63 0.88 22.5 22.5 0.59 15 0.24 0.20 56 19 3.94 3.54 90 100 3.94 100 1.38 35 2.48 2.20 63 56 0.43 11 2.76 70 1.04 2.93 26.5 74.5 19.67 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage OT100E3 Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OT16FT3 - OT100FT3 Door mounted switches 00.00 Inches 00.00 [Millimeters] OT16FT3, OT25FT3, OT40FT3 -- door mounted switch 2.64 67 0.43 0.43 0.51 11 2.05 0.06 0.08 11 13 52 1.5 2 2.13 54 0.88 22 0.43 1.38 11 MOUNTING HOLE DETAIL 0.51 35 13 1.69 43 OT 16 & 32ET OT63FT3, OT80FT3 -- door mounted switch 1.89 48 0.69 2.72 0.69 17.5 69 1.42 17.5 0.69 17.5 36 0.71 18 0.71 18 0.16 D 4 0.71 18 0.71 0.88 D 22 2.85 1.42 1.89 36 72.5 48 18 MOUNTING HOLE DETAIL 2.56 65 2.07 0.43 11 52.5 0.69 17.5 OT30FT3, OT60FT3, OT100FT3 -- door mounted switch OT63ET3 0.88 66.5 0.55 14 0.88 0.88 22.5 22.5 2.20 56 1.89 48 0.94 24 0.94 0.16 D 24 19 4 0.94 24 1.89 2.20 48 3.94 100 56 0.94 24 0.88 D 22 MOUNTING HOLE DETAIL 0.43 11 19.68 1SXU000023C0202 Rev. A OT100ET3 Revised January 2014 2.76 70 1.04 26.5 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 00.00 Inches 00.00 [Millimeters] Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OT16F6 - OT100F6 6-pole switches OT16, 25, 40F6 -- 6 Pole switches 0.43 0.51 0.43 0.43 0.51 11 13 11 11 13 1.38 35 1.12 28.5 0.18 DIA. 4.5 1.85 0.24 6 47 shaft depth 2.68 68 1.12 28.5 0.43 11 35mm DIN rail 2.36 60 2.13 54 1.38 35 2.22 56.5 2.76 70 0.51 13 0.43 11 0.51 13 2.68 68 OT63, OT80F6 -- 6 Pole switches 0.69 17.5 0.18 DIA. 4.5 0.69 17.5 0.69 17.5 0.69 17.5 0.69 17.5 2.07 52.5 2.40 1.89 48 61 shaft depth 0.24 6 3.60 91.5 3.25 82.5 35mm DIN rail 2.85 72.5 1.89 48 0.69 17.5 0.43 11 2.95 75 2.07 52.5 0.69 17.5 4.13 105 3.31 84 0.43 11 OT30, OT60, OT100F6 -- 6 Pole switches 0.18 DIA. 4.5 0.88 22.5 0.88 22.5 0.98 25.0 0.88 22.5 2.76 70 0.88 22.5 2.50 2.48 63 63.5 shaft depth 19 0.24 6 3.94 100 3.94 100 3.54 90 2.48 63 0.43 11 1.04 26.5 2.99 76 2.76 70 5.51 140 1.04 26.5 3.43 87 19.69 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 35mm DIN rail Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OT16 - OT100F3C Double throw switches 00.00 Inches 00.00 [Millimeters] OT16, OT25, OT40F3C - Double throw switches 0.43 0.51 0.43 0.43 0.51 11 13 11 11 13 1.38 35 1.12 28.5 0.18 DIA. 4.5 1.85 0.24 6 47 shaft depth 2.68 68 1.12 28.5 0.43 11 35mm DIN rail 2.36 60 2.13 54 1.38 35 2.22 56.5 2.76 70 0.51 13 0.43 11 0.51 13 2.68 68 OT45, OT63, OT80F3C - Double throw switches 0.69 17.5 0.18 DIA. 4.5 0.69 17.5 0.69 17.5 0.69 17.5 0.69 17.5 2.07 52.5 2.40 1.89 48 61 shaft depth 0.24 6 3.60 91.5 3.25 82.5 35mm DIN rail 2.85 72.5 1.89 48 0.69 17.5 0.43 11 2.07 52.5 0.69 17.5 4.13 105 2.95 75 3.31 84 0.43 11 OT30, OT60, OT100F3C - Double throw switches 0.18 DIA. 4.5 0.88 22.5 0.88 22.5 0.98 25.0 0.88 22.5 2.76 70 0.88 22.5 2.50 2.48 63 63.5 shaft depth 0.24 6 19 3.94 100 3.94 100 3.54 90 2.48 63 0.43 11 1.04 26.5 2.99 76 2.76 70 5.51 140 1.04 26.5 19.70 1SXU000023C0202 Rev. A 35mm DIN rail 3.43 87 Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions OT200_ -- OT400_ 00.00 Inches 00.00 [Millimeters] Di s sw con Di itc ne me h ct ns es ion s OT200U03 OT400U03 19 19.71 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OT600U03 - OT800U03 00.00 Inches 00.00 [Millimeters] OT600U03 OT800U03 12.76 [324] 6.01 [153] 11.57 [294] 13.78 [350] 3.15 [80] 1.06 [27] 0.35 [9] 6.93 [176] 9.13 [232] 14.65 [372] 18.99 [482] 19 0.77 [20] 0.59 [15] 3.05 [78] 0.80 [20] 0.40 [10] 5.20 [132] 0.54 [14] 1.97 [50] 5.74 [146] 19.72 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions OT1200U03 - OETL-NF1600 00.00 Inches 00.00 [Millimeters] OT1200U03 17.40 [442.00] 16.54 [420.00] 11.62 [295.23] 4.33 [110.00] 5.20 [132.18] 15.20 [386.00] 0.54 [13.63] 0.40 [10.13] 21.75 [552.38] 8.27 [210.00] 10.47 [266.00] 11.30 [287.00] 16.77 [426.00] 0.47 [12.00] 2.24 [57.00] 1.53 [38.88] 1.97 [50.00] 2.47 [62.71] 1.86 [47.29] OS1200 OETL-NF1600 0.55 DIA. 14 3.94 0.47 DIA. 12 100 1.58 40 1.28 0.79 32.5 20 1.38 1.58 35 0.35 DIA. 9 40 0.47 12 25.28 21.50 642 546 7.48 190 8.35 212 3.74 95 19 5.47 4.41 139 0.94 24 10.12 257 2-pole 12.63 321 2-pole Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 15.59 396 3-pole 18.11 460 3-pole 0.59 112 21.06 535 4-pole 15 10.67 271 23.58 599 4-pole OETL-NF1600 Revised January 2014 19.73 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OETL-NF2000 - OETL-NF3150 00.00 Inches 00.00 [Millimeters] OETL-NF2000 - OETL-NF3150 0.55 DIA. 14 3.94 0.47 DIA. 12 100 1.58 40 1.28 0.79 32.5 20 1.38 1.58 35 0.35 DIA. 9 40 0.47 12 25.28 21.50 642 546 7.48 190 8.35 212 3.74 95 5.47 4.41 139 0.94 24 10.12 257 2-pole 12.63 321 2-pole 15.59 396 3-pole 18.11 460 3-pole 0.59 112 21.06 535 4-pole 15 10.67 271 23.58 599 4-pole OETL-NF2000,3150 19 19.74 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions OS30FA_12 -- OS60GJ12 00.00 Inches 00.00 [Millimeters] Di s sw con Di itc ne me h ct ns es ion s OS30FA_12 OS60GJ12 19 19.75 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OS100GJ03 -- OS200J03 00.00 Inches 00.00 [Millimeters] OS100GJ03 6.10 [155.00] 4.11 [104.46] 0.10 [2.50] 1.50 [38.00] 4.92 [125.00] 0.79 [20.00] 7.91 [201.01 OS100GJ30 8.66 [220.00] 6.77 [172.00] 4.49 [114.01] 3.94 [100.00] 3.31 [84.00] 1.38 [35.00] OS200J03 1.38 [35.00] OS100GJ30 19 19.76 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Approximate dimensions OS400J03 -- OS600J03 00.00 Inches 00.00 [Millimeters] Di s sw con Di itc ne me h ct ns es ion s OS400J03 OS600J03 19 19.77 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions OS800L03 -- OS1200L03 00.00 Inches 00.00 [Millimeters] OS800L03 9.18 [233] 4.97 [126] 11.65 [296] 0.69 [17] 13.86 [352] 3.46 [88] 0.35 [9] 9.13 [232] 14.26 [362] 12.03 [306] 6.93 [176] 2.14 [54] 0.24 [6] 0.77 [19] 0.52 [13] OS1200L03 1.49 [38] 1.54 [39] OS800 19 19.78 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for Terminal lugs 00.00 Inches 00.00 [Millimeters] OZXA-24 OZXA-30 3.00 1.57 76 40 0.79 20 0.63 16 0.41 10.5 1.46 37 0.45 0.26 6.5 C.L. 11.5 0.10 4.92 2.5 125 0.18 4.5 OZXA-24 1.38 35 0.41 10.3 OZXA-28 & OZXA-28/2 OZXA-400 2.47 C.L. 0.37 9.5 0.75 19 OZXA-30 3.00 63 76 4.92 125 1.38 C.L. 35 0.41 C.L. 10.3 0.37 9.5 0.75 19 OZXA-28 OZXA-200 19 19.79 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions for Terminal lugs 00.00 Inches 00.00 [Millimeters] OZXA-406 OZXA-800 C.L. OZXA-1200 OZXA-32 2.47 3.00 63 2.96 [75.18] 76 1.35 [34.29] 1.00 [25.40] 1.38 [35.05] 4.92 125 4.91 [124.71] 1.09 [27.69] 1.38 1.38 [35.05] 35 0.41 10.3 C.L. 0.37 9.5 1.19 [30.23] 0.75 19 0.37 [9.40] OZXA-32 1.25 [31.75] 2.47 [62.74] 0.62 [15.75] O0.41 [O10.41] OZXA-1200 19 19.80 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for 16A - 100A conversion mechanisms 00.00 Inches 00.00 [Millimeters] 6 or 8 pole -- OTZW8 For installation of 6 or 8 pole, transfer and bypass mechanisms, the following minimum and maximum mounting dimensions are given below. 0.24 0.24 6 1.18 30 + 6 (0...13) 0.59 STEPS 15 OTZW8 in combination with: Minimum inches/mm Maximum inches/mm OT16F3, OT25F3, OT40F3 3.07/78 N/A OT63F3, OT80F3 3.74/95 N/A OT30F3, OT60F3, OT100F3 3.82/97 N/A OESA-ZW1, OESA-ZW1X in combination with: Minimum inches/mm Maximum1 inches/mm OT16F3, OT25F3, OT40F3 4.61/117 6.57/167 OT63F3, OT80F3 5.31/135 7.28/185 OT30F3, OT60F3, OT100F3 4.84/123 6.81/173 OTZW17, OTZW17X in combination with: Minimum inches/mm Maximum1 inches/mm OT16F3, OT25F3, OT40F3 4.61/117 6.57/167 OT63F3, OT80F3 5.31/135 7.28/185 OT30F3, OT60F3, OT100F3 4.84/123 6.81/173 0.59 15 Double throw switch -- OTZW6, OTZW6X OTZW81.18 2.83 72 1.54 39 30 2.17 55 0.24 6 1.54 39 0.24 6 10.71 272 3.54...9.45 90...240 15mm STEPS 0.59 15 0.24 6 Bypass switch -- OTZW17, OTZW17X OTZW6 1.18 30 2.83 72 1.54 39 2.17 55 0.24 6 1.54 39 0.24 6 3.54...8.27 90...210 15mm STEPS 10.71 272 0.24 6 0.59 15 4.72...9.45 120...240 15mm STEPS 0.24 6 19 Mechanical interlock -- OETL-ZW24 Minimum inches/mm Maximum1 inches/mm OT16F3, OT25F3, OT40F3 3.39 / 86 -- OT63F3, OT80F3 4.09 / 104 -- OT30F3, OT60F3, OT100F3 4.13 / 105 -- OETL-ZW24 in combination with: OTZW17 0.24 6 3.94 100 1 Deeper enclosures will require a longer shaft. Please select a 6mm shaft from page 19.5. 19.81 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions for 125 - 200A conversion mechanisms 00.00 Inches 00.00 [Millimeters] 6 or 8 pole -- OESA-ZW2 1.57 0.47 40 12 7.72 196 0.24 0.24 6 6 4.72 For installation of 6 or 8 pole, transfer and bypass mechanisms, the following minimum and maximum mounting dimensions are given below. 120 OESA-ZW2 in combination with: Minimum inches/mm Maximum inches/mm OT160 - OT200 5.35/136 9.49/241 NOTE: Deeper enclosures will require a longer shaft. Please select a 12mm shaft from page 19.7 and an OETL-ZX95 shaft extension coupler from page 19.10. 1.77...9.49 0.59 45...240 15 (15mm Steps) OESA-ZW2 Double throw switch -- OESA-ZW1, OESA-ZW1X 2.83 72 4.57 116 1.54 39 2.17 55 0.24 6 1.54 39 10.71 272 0.24 6 3.54...9.45 90...240 15mm STEPS 0.59 15 OESA-ZW1, OESA-ZW1X in combination with: Minimum inches/mm Maximum inches/mm OT160 - OT200 4.61/117 6.57/167 NOTE: Deeper enclosures will require a longer shaft. Please select a 6mm shaft from page 19.7 0.24 6 19 Mechanical interlock -- OESA-ZW1 OTZW10 0.24 5 OTZW10 in combination with: Minimum inches/mm Maximum inches/mm OT160 - OT200 4.13 / 105 -- NOTE: Deeper enclosures will require a longer shaft. Please select a 6mm shaft from page 19.7 7.48 190 19.82 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for 400A - 1200A conversion mechanisms 00.00 Inches 00.00 [Millimeters] 6 or 8 pole -- OETL-ZW9 For installation of 6 or 8 pole, transfer and bypass mechanisms, the following minimum and maximum mounting dimensions are given below. 1.46 37 OETL-ZW9 in combination with: Minimum inches/mm Maximum inches/mm OT400 7.52/191 N/A OT600 7.52/191 N/A OETL-NF800A 7.52/191 N/A OETL-NF1200 7.52/191 N/A OETL-ZW12 in combination with: Minimum inches/mm Maximum1 inches/mm OT400 8.19/208 11.73/298 OT600 8.19/208 11.73/298 OETL-NF800A 8.19/208 11.73/298 OETL-NF1200 8.19/208 11.73/298 NOTE: Handle not included 2.36...17.32 0.47 0.79 60...240 12 20 20mm Steps OETL-ZW9 Double throw -- OETL-ZW12 1.89 1.57 4.53 3.54 48 40 115 90 NOTE: Includes YASDA-21 handle 3.31 84 0.47 12 0.47 12 8.27...24.02 26.06 210...610 662 20mm steps 0.79 20 19 0.47 12 OETL-ZW12 1 Deeper enclosures will require a longer shaft. Please select a 12mm shaft from page 19.7 and an OETL-ZX95 shaft extension coupler from pg. 18.10. 19.83 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions for 400A - 3150A conversion mechanisms Bypass switch -- OETL-ZW13 2.07 4.53 3.54 115 90 3.31 52.5 1.32 33.5 12 Inches 00.00 [Millimeters] For installation of 6 or 8 pole, transfer and bypass mechanisms, the following minimum and maximum mounting dimensions are given below. Maximum1 inches/mm OETL-ZW12 in combination with: Minimum inches/mm OT400 8.19/208 11.73/298 OT600 8.19/208 11.73/298 OETL-NF800A 8.19/208 11.73/298 OETL-NF1200 8.19/208 11.73/298 0.47 84 00.00 NOTE: Includes YASDA-21 handle 0.47 12 8.27...22.44 210...570 26.06 662 9.84...24.02 250...610 0.47 12 0.79 20 0.47 12 Mechanical interlock -- OETL-ZW3, OETL-ZW14, OETL-ZW15 OETL-ZW13 OETL-ZW3, 14 & 15 in combination with: Minimum inches/mm Maximum1 inches/mm OT400 & OT600 6.50/165 -- OETL-NF800 - OETL-NF1200 6.30/160 -- OETL-NF1600 - OETL-NF3150 12.00/305 -- NOTE: Handle(s) not included. NOTE: OETL-ZW15 is the only mechnical interlock OETL-NF1200 - OETL-NF3150 can use. B A Dimensions in Inches & mm A B OETL-ZW3 11.81 0.47 OETL-ZW14 OETL-ZW15 19 300.0 9.84 12.0 0.47 250.0 12.0 500.0 12.0 19.69 0.47 OETL-ZW3, 14, 15 1 Deeper enclosures will require a longer shaft. Please select a 12mm shaft from page 19.7 and an OETL-ZX95 shaft extension coupler from page 19.10. 19.84 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for Handles 00.00 Inches 00.00 [Millimeters] Selector handles for base and DIN rail mounted switches Selector handles for door mounted switches OH_S1AH1 & OH_S3AH1 OH_S1P_ & OH_S3P_ 0.98 0.98 25 25 48 6.5 48 6.5 1.89 0.26 1.89 0.26 0.125 0.125 3.2 3.2 0.96 0.96 24.5 24.5 0.88 0.55 0.88 0.98 22.5 14 22.5 25 MOUNTING HOLE DETAIL MOUNTING HOLE DETAIL OH_1P, 3P OH_1A,3A OH_S2A_ OH_S1R_ & OH_S3R_ 0.98 1.30 1.42 25 33 2.56 0.39 10 36 1.89 0.26 65 0.71 48 6.5 0.71 18 18 0.53 13.5 0.125 0.16 D B 0.71 4 3.2 0.96 18 0.88 D 24.5 0.39 36 18 22 MOUNTING HOLE DETAIL 10 0.88 1.42 0.71 22.5 0.55 14 MOUNTING HOLE DETAIL OH_2A_ OH_1R, 3R OH_S2P_ 1.30 33 2.56 0.39 65 10 0.125 3.2 0.96 24.5 0.88 0.98 22.5 25 MOUNTING HOLE DETAIL OH_2P_ OH_S2R_ 1.89 1.30 48 33 0.39 10 2.56 19 1.42 65 36 0.71 18 0.71 18 0.53 13.5 0.16 D 0.71 4 18 0.71 0.88 D 36 48 18 22 0.39 1.42 1.89 MOUNTING HOLE DETAIL 10 OH_2R_ 19.85 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions for Handles 00.00 Inches 00.00 [Millimeters] Pistol handles A L Catalog number Inches/ mm 2.66 1.77 67.5 45 2.09 B 53 0.24 0.20 6 5 D 1.22 D 31 45 L 100 OH_45J6 OH_65J6 OH_80J6 1.8/45 2.6/65 3.1/80 0.24/6 0.24/6 0.24/6 1, 3R, 12 1, 3R, 12 1, 3R, 12 OH_125J12 OH_145J12 OH_175J12 4.9/125 5.7/145 6.9/175 0.47/12 0.47/12 0.47/12 1, 3R, 12 1, 3R, 12 1, 3R, 12 OH_80L6 3.1/80 0.24/6 1, 3R, 4, 4X, 12 OH_145L12 5.7/145 0.47/12 1, 3R, 4, 4X, 12 OH_175L12 6.9/175 0.47/12 1, 3R, 4, 4X, 12 2.76 70.0 1.57 40 NEMA / UL Type __ = Handle color, B (Black) or Y (Red/Yellow) MOUNTING HOLE DETAIL 3.94 B Shaft size Inches/ mm B 2.20 56 0.28 D 7 45 A L catalog number inches/mm 1.77 D 45 B Shaft size inches/mm NEMA Type YASDA-7 8.66/220 0.47/12 1, 3R, 4, 4X, 12 YASDA-8 8.66/220 0.47/12 1, 3R, 4, 4X, 12 YASDA-21 8.66/220 0.47/12 1, 3R, 4, 4X, 12 YASDA-6 12.60/320 0.47/12 1, 3R, 4, 4X, 12 MOUNTING HOLE DETAIL L 1.22 31 METAL HANDLE 1.46 .20 0.24 5 6 37 19 O 2.72 69 2.01 51 2.09 53 2.09 53 Handle type type OHM45L5 Handle L 1.8/45 L B .2/5 B OHM65L5 OHM65L6 2.6/65 2.6/65 .2/5 .24/6 OHM65L6 OHM125L12 OHM175L12 OHM125L12 OHM175L12 OHM275L12 OHM275L12 2.6/65 4.9/125 4.9/125 6.9/175 10.8/275 6.9/175 10.8/225 .2/6 .5/12 .5/12 .5/12 .47/12 .47/12 .47/12 19.86 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Di s sw con Di itc ne me h ct ns es ion s Approximate dimensions for Handles 00.00 Inches 00.00 [Millimeters] 54 71 OH_274_12 ,4 O69 274 OH-274J12 53,9 70,7 OH_330_12 329,00 A Catalog number L inches/mm B shaft size inches/mm NEMA Type OHB274-330 10.75/274 0.47/12 1, 3R, 4, 4X, 12 19 19.87 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Approximate dimensions 2, 3 & 4 Pole 2 30A - 1200A Fusible Fusible Frame size OS30_ OS60_ OS100_ OS200_ Enclosure type MH MW H W D mtg. mtg. Weight height width depth height width 1 10.0 8.0 6.0 7.0 7.0 12 3R 10.0 8.0 6.0 10.75 6.0 12 4 10.0 8.0 6.0 10.75 6.0 12 4X SS 10.0 8.0 6.0 10.75 6.0 12 4X Plastic 10.0 8.0 8.0 10.75 6.0 8.0 12 10.0 8.0 6.0 10.75 6.0 12 1 14.0 12.0 8.0 7.0 7.0 13 3R 14.0 12.0 8.0 10.75 6.0 13 4 14.0 12.0 8.0 10.75 6.0 13 4X SS 14.0 12.0 8.0 10.75 6.0 13 4X Plastic 10.0 8.0 8.0 10.75 6.0 9.0 12 14.0 12.0 8.0 10.75 6.0 13 1 14.0 12.0 8.0 11.0 9.0 22 3R 14.0 12.0 8.0 14.75 10.0 22 4 14.0 12.0 8.0 14.75 10.0 22 4X SS 14.0 12.0 8.0 14.75 10.0 22 4X Plastic 14.0 12.0 8.0 14.75 10.0 16 12 14.0 12.0 8.0 14.75 10.0 22 1 24.0 16.0 8.0 25.5 14.5 75 3R 24.0 16.0 8.0 25.5 14.5 75 4 24.0 16.0 8.0 25.5 14.5 75 4X SS 24.0 16.0 8.0 25.5 14.5 75 4X Plastic 1 1 1 1 1 12 24.0 16.0 8.0 25.5 14.5 Frame size OS400_ OS600_ OS800_ Enclosure type 1 44.0 22.0 11.0 37.5 22.5 150 3R 44.0 22.0 11.0 37.5 22.5 150 4 44.0 22.0 11.0 37.5 22.5 150 4X SS 44.0 22.0 11.0 37.5 22.5 150 4X Plastic 1 1 1 1 1 1 12 44.0 22.0 11.0 37.5 22.5 150 1 42.0 36.0 12.0 43.5 34.5 150 3R 42.0 36.0 12.0 43.5 34.5 150 4 42.0 36.0 12.0 43.5 34.5 150 4X SS 42.0 36.0 12.0 43.5 34.5 150 4X Plastic 1 1 1 1 1 1 12 42.0 36.0 12.0 43.5 34.5 150 1 48.0 24.0 12.0 49.5 22.5 170 3R 48.0 24.0 12.0 49.5 22.5 170 4 48.0 24.0 12.0 49.5 22.5 170 4X SS 48.0 24.0 12.0 49.5 22.5 170 4X Plastic 1 1 1 1 1 1 12 48.0 24.0 12.0 49.5 22.5 170 1 60.0 36.0 12.8 62 38 200 3R 60.0 36.0 12.8 62 38 200 60.0 36.0 12.8 62 38 200 4X SS 60.0 36.0 12.8 62 38 200 1 4X Plastic 1 1 1 1 1 1 75 12 60.0 36.0 12.8 62 38 200 1 Please consult factory, enclosures are sized to suit specific customer needs. 2 Some 4-pole switches require larger enclosures. Please consult factory. Inches 00.00 [Millimeters] MW H W D mtg. mtg. Weight height width depth height width 4 OS1200_ 00.00 D W H MH MW 19 19.88 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 00.00 Inches 00.00 [Millimeters] Approximate dimensions 2, 3 & 4 Pole 3 16A - 3150A, Non-fusible Non-Fusible Frame size OT16_ OT25_ OT40_ OT63_ OT80_ OT30 OT60 OT100 Di s sw con Di itc ne me h ct ns es ion s Enclosure type MH MW H W D mtg. mtg. Weight height width depth height width 1 6.0 6.0 4.0 4.0 4.0 4.0 3R 6.0 6.0 4.0 7.75 3.0 4.0 4 6.0 6.0 4.0 6.75 4.0 4.0 4X SS 6.0 6.0 4.0 7.75 3.0 4.0 4X Plastic 6.0 6.0 5.9 6.75 4.0 4.0 12 6.0 6.0 4.0 7.75 3.0 4.0 1 8.0 6.0 4.0 7.0 5.0 3R 8.0 6.0 4.0 8.75 4 8.0 6.0 4.0 4X SS 8.0 6.0 4X Plastic 8.0 12 Frame size Enclosure type MW H W D mtg. mtg. Weight height width depth height width 1 24.0 16.0 8.0 25.5 14.5 50 3R 24.0 16.0 8.0 25.5 14.5 50 4 24.0 16.0 8.0 25.5 14.5 50 4X SS 24.0 16.0 8.0 25.5 14.5 50 4X Plastic 25.0 17.0 10.0 25.5 14.5 40 12 24.0 16.0 8.0 25.5 14.5 50 6.0 1 44.0 22.0 11.0 37.5 22.5 120 4.0 6.0 3R 44.0 22.0 11.0 37.5 22.5 120 8.75 4.0 6.0 4 1 1 1 1 1 1 4.0 8.75 4.0 6.0 4X SS 36.0 24.0 12.0 37.5 22.5 130 6.0 5.9 8.75 4.0 6.0 4X Plastic 1 1 1 1 1 1 8.0 6.0 4.0 8.75 4.0 6.0 12 36.0 24.0 8.0 37.5 22.5 120 1 10.0 8.0 5.0 7.0 7.0 9.0 1 44.0 22.0 11.0 37.5 22.5 120 3R 10.0 8.0 5.0 10.75 6.0 9.0 3R 36.0 24.0 12.0 37.5 22.5 120 4 10.0 8.0 5.0 10.75 6.0 9.0 4 36.0 24.0 12.0 37.5 22.5 120 4X SS 10.0 8.0 5.0 10.75 6.0 9.0 4X SS 36.0 24.0 12.0 37.5 22.5 120 4X Plastic 10.0 8.0 5.9 10.75 6.0 9.0 4X Plastic 40.0 32.0 13.0 41.2 30.2 120 12 10.0 8.0 5.0 10.75 6.0 9.0 12 36.0 24.0 12.0 37.5 22.5 120 1 60.0 36.0 12.0 61.5 34.5 200 3R 60.0 36.0 12.0 61.5 34.5 200 4 60.0 36.0 12.0 61.5 34.5 200 4X SS 60.0 36.0 12.0 61.5 34.5 200 4X Plastic 1 1 1 1 1 1 12 60.0 36.0 12.0 61.5 34.5 200 1 90.0 36.0 24.0 2 2 600 3R 90.0 36.0 24.0 2 2 600 4 1 1 1 1 1 1 4X SS 1 1 1 1 1 1 4X Plastic 1 1 1 1 1 1 12 90.0 36.0 24.0 2 2 600 OT200 OT400 OT600 OT800 OT1200 OETL-NF1600 OETL-NF2000 OETL-NF3150 1 Please consult factory, enclosures are sized to suit specific customer needs. 2 Enclosure is free standing. 3 Some 4-pole switches require larger enclosures. Please consult factory. D W H MH 19 MW 600V, 16A - 3150A 2, 3 and 4-pole switches Enclosure dimensions 19.89 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di eOT16_, eOT32_ eOT Enclosed switches Approximate dimensions eOT16_ - eOT45U 00.00 Inches 00.00 [Millimeters] (enclosure size 1) 0,18 4,5 in mm 0,09 R2,25 0,79 5,98 152 5,98 152 5,51 140 0,29 7,40 2,99 76 1,18 30 6,35 161,4 1,97 50 3,94 1/2 " 3/4 " M25 4,55 115,5 EOT32U_ , EOT45U_ eOT45U_ 1,36 34,5 3,19 81 Knock-outs M20 Handle OHB 2AJ Knock-outs on top and bottom (enclosure size 2 with selector handle) mm in 30.5 1.20 146 5.75 188 7.40 20 0.79 40.3 1.59 88 3.46 200 7.87 188 7.40 176 6.93 O 4.5 0.18 73 2.87 103.5 4.07 138 5.43 34.5 1.36 EOT32U_ , EOT45U_ eOT45U_ (enclosure size 2 with pistol grip handle) mm in 30.5 1.20 146 5.75 188 7.40 20 0.79 40.3 1.59 88 3.46 200 7.87 188 7.40 176 6.93 3/4 " 1 " 73 2.87 19 O 4.5 0.18 103.5 4.07 148.5 5.84 3/4 " 1 " 45 1.77 19.90 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage 00.00 Inches 00.00 [Millimeters] eOT63_ eOT Enclosed manual motor controllers Approximate dimensions eOT63_ Di s sw con Di itc ne me h ct ns es ion s (enclosure size 3 with pistol grip handle) 19 19.91 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage Revised January 2014 1SXU000023C0202 Rev. A ct ne s n o he s sc Di witc sion s en m Di Notes 00.00 Inches 00.00 [Millimeters] 19 19.92 1SXU000023C0202 Rev. A Low Voltage Products & Systems Revised January 2014 ABB Inc. * 888-385-1221 * www.abb.us/lowvoltage