Characteristics 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC A "Pistol grip" For control circuits Environment Conformity to standards EN/IEC 60947-5-1 EN/IEC 60204-32, UL 508, CSA C22-2 n 14 EN/IEC 60947-5-5 and EN/ISO 13850 for versions with trigger action Emergency stop UL type 4X A600-Q600, CSA type 4 A600-Q600 Product certifications Protective treatment Standard version Ambient air temperature For operation For storage "TH" C C Vibration resistance - 25...+ 70 - 40...+ 70 15 gn (10...500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Electric shock protection Class II conforming to IEC 61140 Degree of protection IP 65 conforming to IEC 60529 IK 08 conforming to EN 50102 1 Mechanical durability (in millions of operating cycles) Enclosure Double insulated polypropylene, coloured yellow throughout Cable entry Rubber sleeve with stepped entry diameter for cable O 7...O 15 mm Contact block characteristics Thermal current (lthe) A a AC-15: A600 or Ue = 600 V, le = 1.2 A or Ue = 240 V, Ie = 3 A c DC-13: Q600 or Ue = 600 V, le = 0.1 A or Ue = 250 V, Ie = 0.27 A conforming to EN/IEC 60947-5-1 Appendix A 10 Rated insulation voltage (Ui) V 600, degree of pollution 3, conforming to IEC 60947-1 Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-1 Rated operational characteristics Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5-1 Appendix K Slow break Contact operation Resistance across terminals M y 25 Operating force N 13 to 15 Terminal referencing By numbers conforming to CENELEC EN 50013 Short-circuit protection 10 A cartridge fuse type gG (gl) mm2 Connection Screw and captive cable clamp terminals. Clamping capacity: 1 x 2.5 or 2 x 1.5 with or without cable end Conforming to EN/IEC 60947-5-1 Appendix C. Utilisation categories AC-15 and DC-13. Operating rate: 3600 operating cycles/hour. Load factor: 0.5. Rated operational power d.c. supply c Power broken in W for 1 million operating cycles Millions of operating cycles a.c. supply a 50/60 Hz o Inductive circuit 1 Ithe Voltage V W o 24 65 48 48 120 40 0,6 230 V 127 V 0,4 24...48 V 0,2 0,1 1 References: page 30072/3 2 Dimensions: page 30072/5 2 4 6 Current 10 in A Application schemes: page 30072/5 30072-EN_Ver6.3.indd References 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC A "Pistol grip" For control circuits Complete stations "ready for use" For control of single-speed hoist motors 2 mechanically interlocked Standard Contact block(s) and scheme Per direction For Emergency stop 1 N/O - ZB2 BE101 Reference XAC A201 Weight kg 0.270 - XAC A205 0.300 - XAC A211 0.290 - XAC A215 0.320 1 N/C ZB2 BE102 XAC A2014 0.310 XAC A2054 0.340 XAC A2114 0.310 XAC A2154 0.340 13 Type of operators 11 13 1 N/O ZB2 BE101 11 13 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 12 XAC A2114 14 XAC A2014 11 12 11 12 11 12 1 N/C ZB2 BE102 1 N/C ZB2 BE102 11 1 N/O ZB2 BE101 1 N/C ZB2 BE102 12 11 13 13 14 11 13 12 14 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 14 Booted 1 N/O ZB2 BE101 13 2 Standard mechanically interlocked + 1 trigger action latching Emergency stop O 30 mm operator ZA2 BS834 (1) 12 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 XAC A211 DF565518 DF565517 XAC A201 14 14 Booted 12 1 N/C + 1 N/O ZB2 BE102 + ZB2 BE101 14 14 Number of operators 13 DF565516 DF565515 Functions (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. 30072-EN_Ver6.3.indd 3 References 6 Pendant control stations 6 Double insulated with intuitive operation, type XAC A "Pistol grip" For control circuits Complete stations "ready for use" For control of 2-speed hoist motors 0.320 1 N/C ZB2 BE102 XAC A2074 0.360 XAC A2174 0.360 23 XAC A217 24 - XAC A2074 11 12 11 1 N/C ZB2 BE102 12 23 24 23 13 24 2 step 1 N/O + 1 N/O staggered ZB2 BE101 + ZB2 BE201 13 Booted 2 step 1 N/O + 1 N/O staggered ZB2 BE101 + ZB2 BE201 14 DF565522 2 Standard mechanically interlocked + 1 trigger action latching Emergency stop O 30 mm operator ZA2 BS834 (1) 14 XAC A217 DF565521 XAC A207 2 step 1 N/O + 1 N/O staggered ZB2 BE101 + ZB2 BE201 23 Booted XAC A207 Weight kg 0.320 24 Standard Reference 13 2 mechanically interlocked Contact block(s) and scheme Per direction For Emergency stop 2 step - 1 N/O + 1 N/O staggered ZB2 BE101 + ZB2 BE201 14 Type of operators 13 Number of operators 14 DF565519 DF565520 Functions XAC A2174 Separate components and spare parts Description 803998 803990 Booted pushbutton operators with fixing screws XAC A921 For use with Marking/ Function - XAC A921 Weight kg 0.010 - XAC A922 0.010 - XAC A923 0.010 - XAC A924 0.010 N/O ZB2 BE101 0.015 N/C ZB2 BE102 0.015 ZB2 BE201 0.015 XAC A211p XAC A215p (single-speed) Scheme Reference XAC A923 Contact blocks spring return, slow break XAC A all models 530668 2 ZB2 BEppp 1 530667 XAC A217p (2-speed) N/O staggered XAC A913 Characteristics: page 30072/2 4 Protective cable sleeve Cable - - XAC A913 0.070 + suspension ring O 7 to O 13 mm + cable clamp (1) Trigger action mechanically latching Emergency stop pushbuttons conform to standards EN/IEC 60204-32, EN/ISO 13850, Machinery directive 98/37/EC and standard EN/IEC 60947-5-5. Dimensions: page 30072/5 Application schemes: page 30072/5 30072-EN_Ver6.3.indd Pendant control stations Dimensions, application schemes 6 6 Double insulated with intuitive operation, type XAC A "Pistol grip" For control circuits Complete stations "ready for use" Dimensions XAC A2pp XAC A2ppp internal O 7...9 9...11 7...9 9...11 11...13 13...15 11...13 13...15 45,5 235 235 295 295 internal O 39 52 71 39 52 45,5 101 (1) (1) With trigger action latching O 30 mm Emergency stop ZA2 BS834. Application schemes (typical examples) For control of single-speed reversing motor XAC A2p5p 11 - S1 13 13 12 12 11 11 XAC A2p1p 12 - KM1 A2 A1 - KM2 A2 - KM1 A2 - KM2 A1 A1 A1 14 - S2 A2 11 13 12 - S2 14 13 14 14 - S1 For control of 2-speed reversing motor 23 13 12 11 XAC A2p7p 24 23 13 14 - S1 A1 24 30072-EN_Ver6.3.indd A2 - KM1 A2 - KM A2 - KM2 A1 A1 14 - S2 5 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schneider Electric: XACA201