MICRO SWITCH™ Compact
Precision Limit Switches
14CE Series
Datasheet
2sensing.honeywell.com
What makes our switches better?
Compact construction for minimal real estate on equipment
Gang mounting capability to provide a multi-plunger
limit switch
Rugged, die-cast zinc housing for demanding environments
Variety of cable length options and choice of side or bottom exit
cable/connector for design flexibility
Functionality over a wide temperature range with factory sealed
connectors or wiring
MICRO SWITCH™ 14CE Series
Compact Precision Limit Switches
All MICRO SWITCH™ 14CE Series compact enclosed switches incorporate uorocarbon diaphragm sealing to
provide reliable protection, meeting IP65, IP66, IP67, and IP68, as well as NEMA 1, 2, 3, 3R, 4, 6, 6P, and 13 require-
ments. Versions with a boot seal also meet NEMA 12 requirements (dust, falling dirt, liquid media with solid contami-
nates). The cable or connector and basic switch terminals are encapsulated in an epoxy sealant, offering excellent
resistance in harsh environments. For low temperature applications (down to -40 °C, -40 °F), CE Series switches can
be supplied with low temperature seals and lubricant.
The CE Series switches are rugged and versatile switches which can be applied indoors in many harsh factory oor
applications, as well as on outdoor equipment in extreme temperatures. A full range of actuators are available, includ-
ing plain plungers, roller plungers, side rotary, multi-directional wire, and manually operated. The switches are also
available with the industry standard, M12 micro-change 4-pin connector. MICRO SWITCH™ 14CE products meet
worldwide CE requirements.
CUSTOMIZATION • COMPACT
HIGH PERFORMING • DURABILITY
Big performance in a little package.
3
sensing.honeywell.com
Features
and Benefits
Features
and Benefits
RUGGED, COMPACT CONSTRUCTION
MICRO SWITCH™ 14CE Series limit switches’ compact construction requires
minimal real estate on equipment. Consistent performance is delivered in
many demanding environments where petroleum, synthetic or water based fluids
are present. Its die-cast zinc housing and fluorocarbon diaphragm seal maintain
a tightly sealed, IP65/66/67/68 and NEMA 1, 2, 3, 3R, 4, 6, 6P, 12 (boot seal), 13
rugged package.
CUSTOMIZATION
Switches are pre-leaded (harmonized CENELEC cable) or supplied with a M12
four-pin connector to decrease installation time. 14CE Series’ wide selection
of actuators minimize installation or time issues. Cable length variations are
available for equipment requiring different cable lengths with side and bottom exit
cable/connector options for equipment flexibility.
COMPACT DESIGN
Rugged, compact switch designed with the common 25 mm mounting
centers. The 14CE Series is engineered with MICRO SWITCH™ SM switches for
consistent, precise actuation.
LONG LIFE
Mechanical life up to five million cycles for wobble actuators, and up to ten million
cycles for all other actuators delivers long-lasting performance.
DESIGN FLEXIBILITY
Gang mounting capability provides a multi-plunger limit switch option. Low
temperature variants are available for indoor and outdoor applications.
GLOBAL APPLICATIONS
MICRO SWITCH™ 14CE limit switches have CE approval for world-wide use.
High performance switch for small spaces
Gang-mounting option
4sensing.honeywell.com
MACHINE TOOLS
Detects tool and piece part location on CNC and other machining equipment
OFF-ROAD EQUIPMENT
Used as a cab door switch on crane booms
MATERIAL HANDLING
Used in forklifts and dock locks for trucks and trailers, and vehicle wash systems
ACCESS AND MOBILITY SOLUTIONS
Often used on vehicle wheelchair lifts and stairway lifts
TEXTILE MACHINERY
Senses roll size, tensioning, and other functions
ROBOTICS
Controls arm movement limits
PACKAGING EQUIPMENT
Often used on stretch pallet wrapping equipment
PRINT TRADE MACHINERY
Senses roll size, tensioning, along with controlling gates and panels
AGRICULTURAL MACHINERY
Used on grain and livestock equipment
Potential Applications
5
sensing.honeywell.com
MICRO SWITCH™ Compact Precision Limit Switches
Table 1. Specifications
Characteristic Parameter
Description compact enclosed limit switch
Actuators
Top pin plunger (14CE1-) • Parallel roller plunger (14CE2-)
Cross roller plunger (14CE3-) • Front rotary (14CE16-)
• Top pin plunger with boot seal (14CE18-) • Top adjustable plunger (14CE19-)
• Wobble (14CE20-) • Manually operated (14CE22-)
Top pin plunger, panel mount (14CE27-) • Ball bearing plunger (14CE66-)
Top roller plunger, parallel and panel mount (14CE28-)
• Top roller plunger, perpendicular, panel mount (14CE29-)
• Top roller plunger, parallel and boot sealed (14CE31-)
• Top roller plunger, perpendicular, boot seal (14CE55-)
Terminations
Harmonized CENELEC PVC sheathed 4 x 0,75 mm2 (18 AWG) cable
Connector (dc), 4-pin male, M12 thread (-Q)
Connector (ac), 4-pin male, 1/2 in x 20 thread (-Q1)
Switching options SPDT, snap action contacts (1NC/1NO)
Sealing IP65, IP66, IP67, IP68
NEMA 1, 2, 3, 3R, 4, 6, 6P, 12 (boot seal), 13
Operating temperature 0 °C to 70 °C [32 °F to 158 °F]; optional -40 °C to 70 °C [-40 °F to 158 °F]
Mechanical life up to 10 million
up to 5 million (wobble actuators)
Thermal current 1 A, 3 A, 5 A (depending upon model)
Rated insulation voltage (Ui) 250 V
Rated impulse withstand volt-
age (Uimp) 1.5 kV
Pollution degree 3
Min. actuation speed 0.003 m/s
Max. actuation speed 0.1 m/s
Max. actuation frequency ac – 200 Hz; dc – 20 Hz
Shock 50 g – IEC68-2-27
Vibration 10 G – IEC68-2-6
Approvals CE
Conforming to standards IEC947-5-1, EN 60947-5-1; AC14 D300, DC13 R300
Table 2. Electrical Ratings (in amperes)
Model example Contacts Rating
14CE_-_ Silver contacts A
14CE_-_G Gold contacts B
14CE_-Q, -AQ, -AQ1 Silver contacts C with 4-pin connector
Rating code Electrical Rating Make Break
A
240 Vac, ind. 1.2 0.2
240 Vac, res. 5 5
28 Vdc, res. 3 3
28 Vdc, ind. 3 3
5 A, 1/10 HP, 125 Vac or 250 Vac
B1 A res., 0.5 A ind., 30 Vdc
1 A, 125 Vac
C 3 A, 125 Vac or 250 Vac
6sensing.honeywell.com
14CE Series
SWITCHING AND LEAD IDENTIFICATION
14CE
GREEN/YELLOW
GREY
1
BROWN
2
3
BLACK
SPDT
1 = Common
2 = Normally Closed
3 = Normally Open
PINOUTS
Connector - (dc) (-Q) Connector (ac) (-Q1)
1
3
2
1
3NO
NC
C
NO
NC
C
2
1
3
2
1
3NO
NC
C
NO
NC
C
2
CONNECTOR VERSIONS
The 14CE Series is available with a 4-pin, M12 size connector in
both bottom and side exit versions.
-Q Version -Q1 Version
8.0
Brad Harrison connecto
r
CAT. No.80466 M12
Thread
15
OPTION Q
dc type 4 pin male,
M12 thread
15
OPTION Q1
ac type, 4 pin male,
1/2 in x 20 thread
MOUNTING
MICRO SWITCH™ 14CE Series switches are mounted by using
two M5 screws. The mounting holes are counter bored to keep
the screw heads within the overall switch housing dimensions.
GANG MOUNT CAPABILITY
The housing on the 14CE Series has been designed to enable
the user to build his own multiple plunger switch by gang mount-
ing several switches. All pin plunger and roller plunger types are
suitable for gang mounting. There is a 16 mm distance between
the plungers. Both Series are very versatile that even a lever-type
version could be added at the end of the row.
BOTTOM EXIT OR SIDE EXIT ORIENTATION
The CE Series has been designed with a pre-wired cable or con-
nector tted in the bottom of the switch housing. Other variations
are available with a side-exit cable or connector.
GOLD CONTACT VERSIONS
For low energy applications (up to 30 Vdc, 1 A), gold contact ver-
sions of the 14CE switches can be supplied upon request.
7
sensing.honeywell.com
MICRO SWITCH™ Compact Precision Limit Switches
44 mm max.
[1.73 in max.]
25 mm
[0.98 in]
16 mm max.
[0.63 in max.]
40 mm max.
[1.57 in max.]
Max. free length
Operating
position (OP)
3 mm min.
[0.12 in min.]
8,0 mm
[0.31 in]
8,0 mm
[0.32 in]
7,6 mm
[0.30 in]
Pretravel (PT)
Overtravel (OT)
CABLE VERSION
TYPE
Q OE TYPE
Q1
M12
thread
1/2 x 20 UNF
thread
Two (2) holes Ø 5.1 mm [Ø 0.2 in] dia.,
c/bore 10,2 mm dia x 6 mm deep [0.40 in dia x 0.24 in deep]
(Both sides - option “A” only)
15,0 mm
[0.59 in] 15,0 mm
[0.59 in]
5,0 mm ref.
[0.20 in]
4,8 mm ref.
[0.19 in]
Option B. Elongated mounting holes
Two slots Ø 5,1 mm [0.20 in]
c/bore Ø 10,2 mm [0.40 in]
x 6 deep
GENERAL DIMENSIONS • ALL SWITCHES
PRODUCT NOMENCLATURE
3
16
2
1Top pin
plunger
Top roller
plunger, parallel
Top roller
plunger, perp.
Front
rotary
14CE
Switch Type
16
Actuator Type Options1,2
D
B
ASide entry
Elongated
mounting holes
Halogen-free
cable
MICRO SWITCH™ 914CE Miniature Limit Switch
Product Nomenclature
19
18 Top pin plunger
w/ boot seal
Top adjustable
pin plunger
29
31
28
27 Top pin plunger
panel mount
Top roller
plunger, parallel
panel mount
Top roller
plunger, perp.
panel mount
Top roller
plunger, parallel
boot seal
66
55 Top roller
plunger, perp.
boot seal
Top ball bearing
plunger
14CE Series
Compact
Precision
Limit Switch
3
2
11 meter
2 meters
3 meters
44 meters
55 meters
3
Cable Length
20 Coil
wobble
22 Manually oper.
nylon button
HHigh temp.,
150 °C
Connectors
(micro type)
Q1
Qdc type
single keyway
4-pin male, M12
ac type
two keyways
4-pin male, 1/2-20
Bottom exit is
standard.
NOTE: not all combinations of model code are available.
Please contact your Honeywell provider/representative for assistance.
1More than one option may be permissible.
2OPTION K to be discontinued. Replaced with fluorocarbon diaphragm seal, standard switch.
2OPTION KV to be discontinued. Replaced with fluorocarbon diaphragm seal, standard switch.
P
GGold
contacts
Top
mounting
L1 Low temp.
-40 °C, cable
not for flexing
V
LLow temp.,
-40 °C switch
and cable
Vitron seals/
gasket
(front rotary and
booted sealed
plungers only)
8sensing.honeywell.com
14CE Series
14CE1 • Pin Plunger
14CE27 • Pin Plunger Panel Mount
Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
FP
PT
OP
OT
M10 X 1 METRIC THREAD
12 mm [0.49 in]
THREADED LENGTH
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 11,8 N [2.65 lb]
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Silver A Bottom 17,5 mm
[0.69 in]
15,7 mm
[0.62 in] 14CE1-1
Gold B Bottom 17,5 mm
[0.69 in]
15,7 mm
[0.62 in]
Gold-plated
contacts 14CE1-1G
Silver A Side 17,5 mm
[0.69 in]
15,7 mm
[0.62 in] Side exit cable 14CE1-1A
Silver C Bottom 17,5 mm
[0.69 in]
15,7 mm
[0.62 in]
dc-type
connector 14CE1-Q
Silver A Bottom 31,1 mm
[1.23 in]
29,3 mm
[1.15 in] Panel mount 14CE27-1
14CE18 • Boot Sealed Pin Plunger Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
FP
OP
OT
PT
BOOT SEAL
Ø7,0 mm
[Ø0.28 in]
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 22,5 N [5.06 lb]
Silver A Bottom 26,7 mm
[1.05]
24,9 mm
[0.98 in] 14CE18-1
Silver A Side 26,7 mm
[1.05]
24,9 mm
[0.98 in] Side exit cable 14CE18-1A
Silver C Bottom 26,7 mm
[1.05]
24,9 mm
[0.98 in]
dc-type
connector 14CE18-Q
14CE66 • Ball Bearing Plunger Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
FP
OP
OT PT
7,9 mm [0.31 in] DIA
BALL BEARING
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 11,8 N [2.65 lb]
Silver A Bottom 26,2 mm
[1.03 in]
24,4 mm
[0.96 in] 14CE66-1
Silver A Side 26,2 mm
[1.03 in]
24,4 mm
[0.96 in] Side exit cable 14CE66-1A
Ø10,0 mm
[Ø0.39 in]
FP
OP
OT PT
PRODUCT SPECIFICATIONS AND LISTINGS
Contact your Honeywell rep or distributor for additional listings
1 Page 5 for electrical codes
Note: Most part numbers are shown with 1 meter of cable. The -X indicates the number of meters of cable provided: 2-meters, 3-meters, 4-meters, and
5-meters. Custom lengths are also available.
9
sensing.honeywell.com
MICRO SWITCH™ Compact Precision Limit Switches
14CE2 • Roller Plunger
14CE28 • Roller Plunger Panel Mount
Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
FP
PT
OP
OT
M14 X 1 THREAD
ROLLER
Ø 12,4 mm x 4,7 mm
0.48 in x 0.020 in]
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 11,8 N [2.65 lb]
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Silver A Bottom 30,3 mm
[1.19 in]
28,5 mm
[1.12 in] 14CE2-1
Gold B Bottom 30,3 mm
[1.19 in]
28,5 mm
[1.12 in]
Gold-plated
contacts 14CE2-1G
Silver C Bottom 30,3 mm
[1.19 in]
28,5 mm
[1.12 in]
dc-type
connector 14CE2-Q
Silver A Side 30,3 mm
[1.19 in]
28,5 mm
[1.12 in] Side exit cable 14CE2-1A
Silver A Bottom 44,3 mm
[1.75 in]
42,5 mm
[1.67 in]
Panel mount,
2 m cable 14CE28-2
14CE31 • Boot Sealed Roller Plunger Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
FP
OP
OT
PT
BOOT SEAL
ROLLER
Ø 12,4 mm x 4,7 mm
Ø 0.48 in x 0.020 in]
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
36,2 31,434,4
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 17,5 N [3.93 lb]
Silver A Bottom 36,2 mm
[1.43 in]
34,4 mm
[1.36 in] 14CE31-1
Silver A Bottom 36,2 mm
[1.43 in]
34,4 mm
[1.36 in]
Fluorocarbon
seals, 6 m cable 14CE31-6V
14CE3 • Cross Roller Plunger Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 11,8 N [2.65 lb]
Silver A Bottom 30,3 mm
[1.19 in]
28,5 mm
[1.12 in] 14CE3-1
Silver A Side 30,3 mm
[1.19 in]
28,5 mm
[1.12 in]
3 m of cable,
side exit 14CE3-3A
Silver C Bottom 30,3 mm
[1.19 in]
28,5 mm
[1.12 in]
dc-type
connector 14CE3-Q
FP
OP
OT
PT
Ø12,4 mm
[Ø0.49 in]
Ø12,4 mm
[Ø0.49 in]
FP
OP
OT PT
1 Page 5 for electrical codes
Note: Most part numbers are shown with 1 meter of cable. The -X indicates the number of meters of cable provided: 2-meters, 3-meters, 4-meters, and
5-meters. Custom lengths are also available.
10 sensing.honeywell.com
14CE Series
14CE55 • Boot Sealed Cross Roller
Plunger
Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
FP
OP
OT
PT
BOOT SEAL
ROLLER
Ø 12,4 mm x 4,7 mm
Ø 0.48 in x 0.020 in]
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Pretravel • 1,8 mm [0.071 in]
Diff. travel • 0,1 mm [0.004 in]
Overtravel • 3,0 mm [0.118 in]
Oper. force • 17,5 N [3.93 lb]
Silver A Bottom 36,2 mm
[1.43 in]
34,4 mm
[1.36 in] 3 meters of cable 14CE55-3
14CE16 • Side Rotary Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
PT
OT
PT
OT
18,9 mm
[0.74 in]
Actuator shaf
t
Ø7,32 mm
[Ø0.288 in]
DT
DT
FP
Y-BRN
GRY-BLK
Y-BRN
GRY-BLK
Pretravel • 30°
Diff. travel •
Overtravel • 40°
Oper. force • 0,34 Nm [3 in-lb]
Silver A Bottom 14CE16-12
Gold B Bottom
Gold-plated
contacts,
3 meters of cable
14CE16-3G2
Silver C Bottom dc-type
connector 14CE16-Q2
14CE20 • Random Motion
Wire Actuator Wobble
Con-
tacts
Elec
Rating1
Cable
Exit
Free
Position
(FP)
Operating
Position
(OP)
Options Listing
OP
ALL DIRECTIONS
EXCEPT DIRECT
PULL
335,0 mm max.
[13,98 mm max.]
Ø1.8 mm
[Ø0.07 in]
GR
Y-BRN
GRY-BLK
GR
Y-BRN
GRY-BLK
0 28 max.
Oper. position • 28 mm [1.10 in] max.
Oper. force • 0,55 N [0.12 lb] max.
Silver A Bottom
28 mm
[1.10 in]
max.
14CE20-1
1 Page 5 for electrical codes
2 Switch operates on clockwise and counterclockwise rotation of lever shaft
Note: Most part numbers are shown with 1 meter of cable. The -X indicates the number of meters of cable provided: 2-meters, 3-meters, 4-meters, and
5-meters. Custom lengths are also available.
002387-3-EN IL50 GLO
September 2015
Copyright © 2015 Honeywell International Inc. All rights reserved.
Sensing and Productivity Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
your local sales office.
To learn more about Honeywell’s
sensing and switching products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
ADDITIONAL INFORMATION
The following associated literature is available on the Honeywell Web
site at sensing.honeywell.com:
Product installation instructions
Product range guide
Product nomenclature tree
Product application-specific information
Limit and enclosed switches application information
Limit and enclosed switches operating characteristics
Limit and enclosed switches reference standards
Limit and enclosed switches typical applications
Product flyer: CE Family Miniature Limit Switches
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge those
items it finds defective. The foregoing is buyer’s sole remedy
and is in lieu of all other warranties, expressed or implied,
including those of merchantability and fitness for a particu-
lar purpose. In no event shall Honeywell be liable for conse-
quential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.