Description
• Axial-leaded fast-acting thru-hole fuse
• Matte tin-plated copper lead wires
• High temperature epoxy plastic body, UL 94V0
• Low resistance values
Agency Information
• UL Recognition Guide & File numbers: JDYX2 &
E19180.
• CSA Certification Record No: LR 701159 & Class No:
1422 30 and 1422 01.
Environmental Data
• Shock resistance: MIL-STD-202, Method 213B, Test
Condition I (Sawtooth)
• Vibration resistance: MIL-STD-202, Method 201
(10-55Hz x 3 axis/ no load)
• Moisture resistance: MIL-STD-202F, Method 106
• Soldering heat resistance: MIL-STD-202, Method 210
Top side (260ºC, 20 sec)
• Salt spray: MIL-STD-202, Method 101, Test Condition
B (48 Hours)
• Solderability MIL-STD-202, Method 208H
• Operating Temperating: -55ºC to 125ºC
Ordering
• Specify packaging and product code
(i.e., TR1/MCRW100mA)
3.18 ± 0.1___
7.1 ± 0.5 (0.125 ± 0.004)
(0.280 ± 0.020)
“A”
“B”
3.18 ± 0.1 diameter
(0.125 ± 0.004)
“A” diameter
Construction
Dimensions - mm (in)
End View
* AC Interrupting Rating (Measured at designated voltage, 100%) DC Interrupting Rating (Measured at designated voltage, rise time of less than 50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current, rise time of calibrated circuit less than 50 microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Electrical Characteristics
% of Amp Rating Opening Time
100% 4 hours minimum
200% 5 seconds maximum
Amps “A” Diameter
100mA - 7A 0.025"
10A - 15A 0.032"
Packaging Code “B” Length
BK1 1.5"
TR1 1.13"
Specifications
Voltage Interrupting Resistance Typical Typical
Part Number Rating Rating* (amps) (ΩΩ)** Melt Voltage
Vac/dc Vac Vdc Typical I2t† Drop‡
MCRW100mA 125 50 300 15.5 0.0006 3.00
MCRW125mA 125 50 300 2.2 0.0009 0.61
MCRW150mA 125 50 300 1.6 0.0015 0.54
MCRW200mA 125 50 300 1.2 0.002 0.48
MCRW250mA 125 50 300 0.85 0.004 0.43
MCRW300mA 125 50 300 0.62 0.008 0.39
MCRW375mA 125 50 300 0.49 0.012 0.35
MCRW500mA 125 50 300 0.33 0.023 0.31
MCRW750mA 125 50 300 0.19 0.056 0.25
MCRW1A 125 50 300 0.13 0.10 0.22
MCRW1.5A 125 50 300 0.07 0.25 0.18
MCRW2A 125 50 300 0.054 0.27 0.24
MCRW2.5A 125 50 300 0.041 0.50 0.22
MCRW3A 125 50 300 0.031 0.9 0.20
MCRW4A 125 50 300 0.023 1.6 0.19
MCRW5A 125 50 300 0.018 3 0.17
MCRW7A 125 50 300 0.012 7 0.15
MCRW10A 125 50 300 0.007 21 0.098
MCRW12A 125 50 300 0.006 35 0.093
MCRW15A 125 50 300 0.004 63 0.088
Subminiature Microtron®Fuses
MCRW Series, Fast-Acting, Wire-in-Air
HALOGEN
HF
FREE