Low Current Control Transformers
P-8361, P-8362, P-8364
ELECTROCUTION HAZARD
Disconnect electric power to system at
main fuse or circuit breaker box before
servicing. Failure to do so could result
in death or serious injury.
FIRE HAZARD
Do not exceed transformer ratings.
Higher voltage may damage control
and could cause personal injury or
property damage.
SPECIFICATIONS:
WARNING
!
INPUT: 117V, 50/60Hz
OUTPUT: SEE NOTE 1.
INSULATION RATING: CLASS A (105°C)
DIELECTRIC STRENGTH: 1500VRMS
TEMPERATURE RISE: 65°C RISE ABOVE
40°C AMBIENT
NOTE:
1. Three isolated 12 Volt secondaries (one with
a center tap) provide many combinations of
output voltages and currents by series or
parallel combinations.
2. All leads #22 AWG, 8" long minimum,
stripped and tinned 3/8".
BROWN
3
RED
6
BLUE
5
SLATE
4
PRI.
117V
50/60HZ
SCHEMATIC DIAGRAM
Dots indicates like polarity
2
BLACK
BLACK 1
YELLOW
9
GRN/YEL
C.T.
8
ORANGE
7
12V
12V
12V
D
MAX
W
MAX
MW
.188 ± .015 DIA.
H
MAX
(2 HOLES)
Amperes
each Sec.
Dimensions - Inches
HWDMW
P-8361 0.10 1.75 2.06 1.62 1.72 0.36
P-8362 0.15 2.06 2.44 1.88 2.00 0.60
P-8364 0.50 2.53 2.94 2.13 2.38 1.25
STANCOR
Part No.
Wt.
Lbs.
www.stancor.com
PART NO. 37-6875B
Replaces 37-6875A
0741