M iniature Amplified Pressure Sensors 0.3 psi to 100 psi Pressure Sensors Features Applications * Medical Instrumentation * Environmental Instrumentation * HVAC Instrumentation all sensors * 0 to 0.3 to 0 to 30 psi Pressure Ranges * Ratiometric 4V Output * Temperature Compensated * Calibrated Zero and Span The Miniature Amplified line of pressure sensors is based upon technology developed over years of development in the pressure sensor industry. This model provides a ratiometric 4-volt output with superior output characteristics. The sensor housing has been designed specifically to reduce package induced parasitic stress and strain. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure. e www.allsensors.com General Description such as air, dry gases and the like. The output of the device is ratiometric to the supply voltage over a supply voltage range of 4.5 to 5.5 volts. Physical Dimensions 0.30 (7.6) 0.50 (12.7) B-port A-port 0.380 0.62 (15.7) Pin 1 2 3 4 0.10 Typical (2.54) 0.080 O.D. (2.00) D1 version or G verison Equivalent Circuit All Sensors DS-0103 Rev A D2 version a 16035 Vineyard Blvd. Moragtn Hill, CA 95037 p 408 225 4314 internally compensated using an ASIC compensation technique. This series is intended for use with non-corrosive, non-ionic working fluids f 408 225 2079 These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. Each sensor is Pressure Sensor Ratings Environmental Specifications +4.5 to +5.5 Vdc Supply Voltage, Vs Temperature Ranges -10 to +10 psig Common-mode pressure Compensated 250C Lead Temperature, max (soldering 2-4 sec.) 5 to 50 C Operating -25 to 85 C Storage -40 to 125 C Humidity Limits 0 to 95% RH (non condensing) Standard Pressure Ranges Part Number Operating Pressure Nominal Span Proof Pressure Burst Pressure 0.3 PSI-Dx-4V-MINI 0.3 PSI 4V 5 PSI 10 PSI 0.3 PSI-G-4V-MINI 0 - 0.3 PSI 4V 5 PSI 10 PSI 1 PSI-Dx-4V-MINI 1 PSI 4V 5 PSI 10 PSI 1 PSI-G-4V-MINI 0 - 1 PSI 4V 5 PSI 10 PSI 5 PSI-Dx-4V-MINI 5 PSI 4V 15 PSI 30 PSI 5 PSI-G-4V-MINI 0 - 5 PSI 4V 15 PSI 30 PSI 15 PSI-A-4V-MINI 0 - 15 PSIA 4V 45 PSI 60 PSI 15 PSI-Dx-4V-MINI 15 PSI 4V 45 PSI 60 PSI 15 PSI-G-4V-MINI 0 - 15 PSI 4V 45 PSI 60 PSI 30 PSI-A-4V-MINI 0 - 30 PSIA 4V 60 PSI 60 PSI 30 PSI-Dx-4V-MINI 30 PSI 4V 60 PSI 60 PSI 30 PSI-G-4V-MINI 0 - 30 PSI 4V 60 PSI 100 PSI BARO-A-4V-MINI 600 - 1100 mbar 4V 45 PSI 60 PSI Performance Characteristics for 0.3 PSI-Dx-4V-MINI Parameter, note 1 Minimum Operating Range, differential pressure Nominal Maximum 0.3 Units PSI 1.90 2.0 2.10 volt 2.15 2.25 2.35 volt Offset Temperature Shift (5C-50C), note 2 40 mvolt Linearity, hysteresis error, note 4 0.5 %fs 2 %span Output Span, note 5 Offset Voltage @ zero differential pressure Span Shift (5C-50C), note 2 Specification Notes NOTE 1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B. NOTE 2: SHIFT IS RELATIVE TO 25C. NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE. NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT. NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS FOR MINUS TO PLUS FULL SCALE PRESSURE. M iniature Amplified Output Medium Pressure Sensor Performance Characteristics for 0.3 PSI-G-4V-MINI Maximum PSI Output Span, note 5 3.90 4.0 4.10 volt Offset Voltage @ zero pressure 0.15 0.25 0.35 volt Offset Temperature Shift (5C-50C), note 2 40 mvolt Linearity, hysteresis error, note 4 0.5 %fs 2 %span Maximum Units Span Shift (5C-50C), note 2 Performance Characteristics for 1 PSI-D-4V-MINI Parameter, note 1 Minimum Operating Range, differential pressure Output Span, note 5 Nominal 1.0 PSI 1.90 2.0 2.10 volt 2.15 2.25 2.35 volt Offset Temperature Shift (5C to 50C), note 2 40 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Maximum Units Offset Voltage @ zero differential pressure Span Shift (5C to 50C), note 2 Performance Characteristics for: 1 PSI-G-4V-MINI Parameter, NOTE 1 Minimum Operating Range, gage pressure Output Span, 1.0 PSI 3.90 4.0 4.10 volt 0.15 0.25 0.35 volt Offset Temperature Shift (5C to 50C), note 2 40 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Maximum Units NOTE 5 Nominal Offset Voltage @ zero pressure Span Shift (5C to 50C), note 2 Performance Characteristics for: 5 PSI-D-4V-MINI Parameter, NOTE 1 Minimum Operating Range, differential pressure Output Span, NOTE 5 Nominal 5.0 PSI 1.90 2.0 2.10 volt 2.15 2.25 2.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Offset Voltage @ zero differential pressure Span Shift (5C to 50C), note 2 All Sensors DS-0103 Rev A all sensors 0.3 Units e www.allsensors.com Operating Range, gage pressure Nominal f 408 225 2079 Minimum a 16035 Vineyard Blvd. Moragtn Hill, CA 95037 p 408 225 4314 Parameter, note 1 Performance Characteristics for: 5 PSI-G-4V-MINI Parameter, NOTE 1 Minimum Operating Range, gage pressure Output Span, Nominal Maximum 5.0 Units PSI 3.90 4.0 4.10 volt 0.15 0.25 0.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Maximum Units 15 psia NOTE 5 Offset Voltage @ zero pressure Span Shift (5C to 50C), note 2 Performance Characteristics for 15 PSI-A-4V-MINI Parameter, note 1 Minimum Operating Range, absolute pressure Nominal 0 Output Span, note 5 3.90 4.0 4.10 volt Offset Voltage @ zero pressure 0.15 0.25 0.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Maximum Units Span Shift (5C to 50C), note 2 Performance Characteristics for 15 PSI-Dx-4V-MINI Parameter, note 1 Minimum Operating Range, differential pressure Output Span, note 5 Nominal 15.0 PSI 1.90 2.0 2.10 volt 2.15 2.25 2.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Maximum Units 1100 mBar Offset Voltage @ zero differential pressure Span Shift (5C to 50C), note 2 Performance Characteristics for BARO-A-4V-MINI Parameter, note 1 Minimum Nominal Operating Range, absolute pressure 600 Output Span, note 5 3.90 4.0 4.10 volt Offset Voltage @ zero pressure 0.15 0.25 0.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Span Shift (5C to 50C), note 2 Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 100 useconds. All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. M iniature Amplified Output Medium Pressure Sensor Performance Characteristics for 15 PSI-G-4V-MINI Maximum Units PSI Output Span, note 5 3.90 4.0 4.10 volt Offset Voltage @ zero pressure 0.15 0.25 0.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Maximum Units Span Shift (5C to 50C), note 2 Performance Characteristics for 30 PSI-Dx-4V-MINI Parameter, note 1 Minimum Operating Range, differential pressure Nominal 30.0 PSI 1.90 2.0 2.10 volt 2.15 2.25 2.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Maximum Units Output Span, note 5 Offset Voltage @ zero differential pressure Span Shift (5C to 50C), note 2 Performance Characteristics for 30 PSI-G-4V-MINI Parameter, note 1 Minimum Operating Range, gage pressure Nominal 30.0 PSI Output Span, note 5 3.90 4.0 4.10 volt Offset Voltage @ zero pressure 0.15 0.25 0.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Maximum Units Span Shift (5C to 50C), note 2 Performance Characteristics for 30 PSI-A-4V-MINI Parameter, note 1 Minimum Operating Range, absolute pressure Nominal 30.0 PSI Output Span, note 5 3.90 4.0 4.10 volt Offset Voltage @ zero pressure 0.15 0.25 0.35 volt Offset Temperature Shift (5C to 50C), note 2 20 mvolt Linearity, hysteresis error, note 4 0.5 %fs 1 %span Span Shift (5C to 50C), note 2 Specification Notes NOTE 1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO SHIFT IS RELATIVE TO 25C. SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE. NOTE MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT. NOTE THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT SCALE PRESSURE. NOTE NOTE 2: 3: 4: 5: All Sensors PRESSURE PORT B. DS-0103 Rev A VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS FOR MINUS TO PLUS FULL all sensors 15.0 e www.allsensors.com Operating Range, gage pressure Nominal f 408 225 2079 Minimum a 16035 Vineyard Blvd. Moragtn Hill, CA 95037 p 408 225 4314 Parameter, note 1 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: All Sensors: 30 PSI-D1-4V-MINI 30 PSI-G-4V-MINI 1 PSI-D1-4V-MINI 1 PSI-G-4V-MINI 15 PSI-G-4V-MINI 30 PSI-D2-4V-MINI 0.3 PSI-D1-4V-MINI 15 PSI-A-4V-MINI 0.3 PSI-G-4V-MINI 1 PSI-D2-4V-MINI 5 PSI-D1-4V-MINI 5 PSI-G-4V-MINI 30 PSI-A-4V-MINI 5 PSI-D2-4V-MINI 15 PSI-D2-4V-MINI 0.3 PSI-D2-4V-MINI 15 PSI-D1-4V-MINI