Mixed Signal Oscilloscopes
MSO4000B, DPO4000B Series Data Sheet
Features & Benets
Key Performance Specications
1 GHz, 500 MHz, 350 MHz Bandwidth Models
4 Analog Channel Models
16 Digital Channels (MSO Series)
Up to 5 GS/s Sample Rate on All Channels
20 Megapoint Record Length on All Channels
>50,000 wfm/s Maximum Waveform Capture Rate
Standard Passive Voltage Probes with Less than 4 pF Capacitive
Loading and 500 MHz or 1 GHz Analog Bandwidth
Suite of Advanced Triggers
Ease of Use Features
Wave Inspector®Controls provide Easy Navigation and Automated
Search of Waveform Data
41 Automated Measurements, Waveform Histograms, and FFT Analysis
for Simplied Waveform Analysis
TekVPI®Probe Interface supports Active, Differential, and Current
Probes for Automatic Scaling and Units
10.4 in. (264 mm) Bright XGA Color Display
Small Footprint and Lightweight Only 5.8 in. (147 mm) deep and 11 lb.
(5 kg)
Connectivity
Two USB 2.0 Host Ports on the Front Panel and Two on the Rear Panel
for Quick and Easy Data Storage, Printing, and Connecting a USB
Keyboard
USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or
Direct Printing to a PictBridge®-compatible Printer
Integrated 10/100/1000BASE-T Ethernet Port for Network Connection
and Video Out Port to Export the Oscilloscope Display to a Monitor or
Projector
Optional Serial Triggering and Analysis
Automated Serial Triggering, Decode, and Search Options for I2C,
SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART,
MIL-STD-1553, and I2S/LJ/RJ/TDM
Mixed Signal Design and Analysis (MSO Series)
Automated Triggering, Decode, and Search on Parallel Buses
Per-channel Threshold Settings
Multichannel Setup and Hold Triggering
MagniVu™ High-speed Acquisition Provides 60.6 ps Fine Timing
Resolution on Digital Channels
Optional Application Support
Power Analysis
Limit and Mask Testing
HDTV and Custom Video Analysis
Feature-rich Tools for Debugging Mixed
Signal Designs
With the MSO/DPO4000B Mixed Signal Oscilloscope Series, you can
analyze up to 20 analog and digital signals with a single instrument to
quickly nd and diagnose problems in complex designs. Bandwidths up to
1 GHz and a minimum of 5X oversampling on all channels ensure you have
the performance you need to see fast-changing signal details. To capture
long windows of signal activity while maintaining ne timing resolution, the
MSO/DPO4000B Series offers a deep record length of 20M points standard
on all channels.
With Wave Inspector®controls for rapid waveform navigation, automated
serial and parallel bus analysis, limit and mask testing, and automated
power analysis the MSO/DPO4000B Oscilloscope Series from Tektronix
provides the feature-rich tools you need to simplify and speed debug of
your complex design.
Data Sheet
Discover Fast waveform capture rate - over 50,000 wfm/s - maximizes the probability
of capturing elusive glitches and other infrequent events.
Comprehensive Features Speed Every Stage
of Debug
The MSO/DPO4000B Series offers a robust set of features to speed every
stage of debugging your design from quickly discovering an anomaly and
capturing it, to searching your waveform record for the event and analyzing
its characteristics and your device's behavior.
Discover
To debug a design problem, rst you must know it exists. Every
design engineer spends time looking for problems in their design, a
time-consuming and frustrating task without the right debug tools.
The MSO/DPO4000B Series offers the industry's most complete
visualization of signals, providing fast insight into the real operation of your
device. A fast waveform capture rate - greater than 50,000 waveforms
per second - enables you to see glitches and other infrequent transients
within seconds, revealing the true nature of device faults. A digital phosphor
display with intensity grading shows the history of a signal's activity by
intensifying areas of the signal that occur more frequently, providing a visual
display of just how often anomalies occur.
Capture Triggering on a specic transmit data packet going across an RS-232 bus. A
complete set of triggers, including triggers for specic serial packet content, ensures you
quickly capture your event of interest.
Capture
Discovering a device fault is only the rst step. Next, you must capture the
event of interest to identify root cause.
Accurately capturing any signal of interest begins with proper probing. The
MSO/DPO4000B Series includes four low-capacitance probes for accurate
signal capture. These industry-rst high-impedance passive voltage probes
have less than 4 pF of capacitive loading to minimize the affect of the probe
on your circuit's operation, offering the performance of an active probe with
the exibility of a passive probe.
The MSO/DPO4000B Series provides a complete set of triggers including
runt, timeout, logic, pulse width/glitch, setup/hold violation, serial packet,
and parallel data to help quickly nd your event. With up to a 20M point
record length, you can capture many events of interest, even thousands of
serial packets, in a single acquisition for further analysis while maintaining
high resolution to zoom in on ne signal details.
From triggering on specic packet content to automatic decode in
multiple data formats, the MSO/DPO4000B Series provides integrated
support for the industry's broadest range of serial buses I2C, SPI, USB,
Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and
I2S/LJ/RJ/TDM. The ability to decode up to four serial and/or parallel buses
simultaneously means you gain insight into system-level problems quickly.
To further help troubleshoot system-level interactions in complex embedded
systems, the MSO4000B Series offers 16 digital channels in addition to
its analog channels. Since the digital channels are fully integrated into
the oscilloscope, you can trigger across all input channels, automatically
time correlating all analog, digital, and serial signals. The MagniVu™
high-speed acquisition enables you to acquire ne signal detail (up to
60.6 ps resolution) around the trigger point for precision measurements.
MagniVu is essential for making accurate timing measurements for setup
and hold, clock delay, signal skew, and glitch characterization.
2www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
Search–I
2C decode showing results from a Wave Inspector search for Address value
50. Wave Inspector controls provide unprecedented efciency in viewing and navigating
waveform data.
Search
Finding your event of interest in a long waveform record can be time
consuming without the right search tools. With today's record lengths
pushing beyond a million data points, locating your event can mean scrolling
through thousands of screens of signal activity.
The MSO/DPO4000B Series offers the industry's most comprehensive
search and waveform navigation with its innovative Wave Inspector®
controls. These controls speed panning and zooming through your record.
With a unique force-feedback system, you can move from one end of your
record to the other in just seconds. User marks allow you to mark any
location that you may want to reference later for further investigation. Or,
automatically search your record for criteria you dene. Wave Inspector
will instantly search your entire record, including analog, digital, and serial
bus data. Along the way it will automatically mark every occurrence of your
dened event so you can quickly move between events.
Analyze
Verifying that your prototype's performance matches simulations and meets
the project's design goals requires analyzing its behavior. Tasks can range
from simple checks of rise times and pulse widths to sophisticated power
loss analysis and investigation of noise sources.
Analyze Waveform histogram of a falling edge showing the distribution of edge position
(jitter) over time. Included are numeric measurements made on the waveform histogram
data. A comprehensive set of integrated analysis tools speeds verication of your design's
performance.
The MSO/DPO4000B Series offers a comprehensive set of integrated
analysis tools including waveform- and screen-based cursors, 41
automated measurements, advanced waveform math including arbitrary
equation editing, waveform histograms, FFT analysis, and trend plots for
visually determining how a measurement is changing over time. Specialized
application support for serial bus analysis, power supply design, limit and
mask testing, and video design and development is also available.
For extended analysis, National Instrument's LabVIEW SignalExpress™
Tektronix Edition provides over 200 built-in functions including time and
frequency domain analysis, data logging, and customizable reports.
Mixed Domain Analysis
WorkingwithRFsignals? BesuretocheckouttheMDO4000Series–
the world's rst Mixed Domain Oscilloscope. Built on the MSO4000B
oscilloscope platform, the MDO4000 Series offers a built-in spectrum
analyzer (up to 6 GHz). This combination offers you the ability to
capture time-correlated analog, digital, and RF signals in a single
instrument. For more information on the MDO4000 Series, please visit
www.tektronix.com/mdo4000.
www.tektronix.com 3
Data Sheet
Wave Inspector controls provide unprecedented efciency in viewing, navigating, and
analyzing waveform data. Zip through your 20M point record by turning the outer pan
control (1). Get from the beginning to end in seconds. See something of interest and want
to see more details? Just turn the inner zoom control (2).
Wave Inspector®Navigation and Search
A 20M point record length represents thousands of screens of information.
The MSO/DPO4000B Series enables you to nd your event in seconds with
Wave Inspector, the industry's best tool for navigation and search.
Wave Inspector offers the following innovative controls:
Zoom/Pan
A dedicated, two-tier front-panel control provides intuitive control of both
zooming and panning. The inner control adjusts the zoom factor (or zoom
scale); turning it clockwise activates zoom and goes to progressively higher
zoom factors, while turning it counterclockwise results in lower zoom factors
and eventually turning zoom off. No longer do you need to navigate through
multiple menus to adjust your zoom view. The outer control pans the zoom
box across the waveform to quickly get to the portion of waveform you are
interested in. The outer control also utilizes force feedback to determine
how fast to pan on the waveform. The farther you turn the outer control, the
faster the zoom box moves. Pan direction is changed by simply turning the
control the other way.
Play/Pause
A dedicated Play/Pause front-panel button scrolls the waveform across the
display automatically while you look for anomalies or an event of interest.
Playback speed and direction are controlled using the intuitive pan control.
Once again, turning the control further makes the waveform scroll faster and
changing direction is as simple as turning the control the other way.
Search step 1: You dene what you would like to nd.
Search step 2: Wave Inspector automatically searches through the record and marks each
event with a hollow white triangle. You can then use the Previous and Next buttons to
jump from one event to the next.
User Marks
Press the Set Mark front-panel button to place one or more marks on
the waveform. Navigating between marks is as simple as pressing the
Previous ()andNext () buttons on the front panel.
Search Marks
The Search button allows you to automatically search through your long
acquisition looking for user-dened events. All occurrences of the event
are highlighted with search marks and are easily navigated to, using the
front-panel Previous () and Next () buttons. Search types include
edge, pulse width/glitch, timeout, runt, logic, setup and hold, rise/fall
time, parallel bus, and I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay,
RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM packet content.
4www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
Digital phosphor technology enables greater than 50,000 wfm/s waveform capture rate
and real-time intensity grading on the MSO/DPO4000B Series.
Digital Phosphor Technology
The MSO/DPO4000B Series' digital phosphor technology provides you with
fast insight into the real operation of your device. Its fast waveform capture
rate - greater than 50,000 wfm/s - gives you a high probability of quickly
seeing the infrequent problems common in digital systems: runt pulses,
glitches, timing issues, and more.
Waveforms are superimposed with one another and waveform points that
occur more frequently are intensied. This quickly highlights the events
that over time occur more often or, in the case of infrequent anomalies,
occur less often.
With the MSO/DPO4000B Series, you can choose innite persistence or
variable persistence (including zero persistence), determining how long
the previous waveform acquisitions stay on-screen. This allows you to
determine how often an anomaly is occurring.
Accurate High-speed Probing
The TPP Series probes, included standard with every MSO/DPO4000B
Series oscilloscope, provide up to 1 GHz of analog bandwidth, and less
than 4 pF of capacitive loading. The extremely low capacitive loading
minimizes adverse affects on your circuits and is more forgiving of longer
ground leads. And, since the probe bandwidth matches your oscilloscope
bandwidth, you can see the high-frequency components in your signal
which is critical for high-speed applications. The TPP Series passive
voltage probes offer all the benets of general-purpose probes like high
dynamic range, exible connection options, and robust mechanical design,
while providing the performance of active probes.
Mixed Signal Design and Analysis
(MSO Series)
The MSO4000B Series Mixed Signal Oscilloscopes provide 16 digital
channels. These channels are tightly integrated into the oscilloscope's user
The MSO Series provides 16 integrated digital channels enabling you to view and analyze
time-correlated analog and digital signals.
With the color-coded digital waveform display, groups are created by simply placing digital
channels together on the screen, allowing the digital channels to be moved as a group.
You can set threshold values for each channel, enabling support for up to 16 different
logic families.
interface, simplifying operation and making it possible to solve mixed-signal
issues easily.
Color-coded Digital Waveform Display
The MSO4000B Series has redened the way you view digital waveforms.
One common problem shared by both logic analyzers and mixed signal
oscilloscopes is determining if data is a one or a zero when zoomed in far
enough that the digital trace stays at all the way across the display. The
MSO4000B Series has color-coded digital traces, displaying ones in green
and zeros in blue.
www.tektronix.com 5
Data Sheet
White edges indicate additional information is available by zooming in. As shown here,
zooming in on the white edge reveals a hidden glitch.
The MagniVu high-resolution record provides 60.6 ps timing resolution, enabling you to
make critical timing measurements on your digital waveforms.
The multiple transition detection hardware of the MSO4000B Series will
show you a white edge on the display when the system detects multiple
transitions. White edges indicate that more information is available by
zooming in or acquiring at faster sampling rates. In most cases zooming in
will reveal the pulse that was not viewable with the previous settings. If the
white edge is still present after zooming in as far as possible, this indicates
that increasing the sample rate on the next acquisition will reveal higher
frequency information than the previous settings could acquire.
The P6616 MSO probe offers two eight-channel pods to simplify connecting to your
device.
The MSO4000B Series simplies channel setup by allowing you to group
digital waveforms and enter waveform labels by using a USB keyboard.
By simply placing digital waveforms next to each other, they form a group.
Once a group is formed, you can position all the channels contained in that
group collectively. This greatly reduces the normal setup time associated
with positioning channels individually.
MagniVu™ High-speed Acquisition
The main digital acquisition mode on the MSO4000B Series will capture
up to 20M points at 500 MS/s (2 ns resolution). In addition to the main
record, the MSO4000B Series provides an ultra high-resolution record
called MagniVu which acquires 10,000 points at up to 16.5 GS/s (60.6 ps
resolution). Both main and MagniVu waveforms are acquired on every
trigger and can be switched between in the display at any time, running
or stopped. MagniVu provides signicantly ner timing resolution than
comparable MSOs on the market, instilling condence when making critical
timing measurements on digital waveforms.
P6616 MSO Probe
This unique probe design offers two eight-channel pods. Each channel ends
with a probe tip featuring a recessed ground for simplied connection to the
device under test. The coax on the rst channel of each pod is colored blue
making it easy to identify. The common ground uses an automotive-style
connector making it easy to create custom grounds for connecting to
the device under test. When connecting to square pins, the P6616 has
an adapter that attaches to the probe head extending the probe ground
ush with the probe tip so you can attach to a header. The P6616 offers
outstanding electrical characteristics, having only 3 pF of capacitive loading,
a 100 kinput resistance, and capable of acquiring toggle rates >500 MHz
and pulses as short as 1 ns in duration.
6www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
Triggeringonaspecic OUT Token packet on a USB full-speed serial bus. The yellow
waveform is the D+ and the blue waveform is the D–. A bus waveform provides decoded
packet content including Start, Sync, PID, Address, End Point, CRC, Data values, and
Stop.
Serial Triggering and Analysis (Optional)
On a serial bus, a single signal often includes address, control, data, and
clock information. This can make isolating events of interest difcult. The
MSO/DPO4000B Series offers a robust set of tools for debugging serial
buses with automatic trigger, decode, and search for I2C, SPI, USB,
Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and
I2S/LJ/RJ/TDM.
Serial Triggering
Trigger on packet content such as start of packet, specic addresses,
specic data content, unique identiers, etc. on popular serial
interfaces such as I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay,
RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM.
Bus Display
Provides a higher-level, combined view of the individual signals (clock, data,
chip enable, etc.) that make up your bus, making it easy to identify where
packets begin and end and identifying subpacket components such as
address, data, identier, CRC, etc.
Event table showing decoded Identier, DLC, DATA, and CRC for every CAN packet in
alongacqu
isition.
Bus Decoding
Tired of having to visually inspect the waveform to count clocks, determine
if each bit is a 1 or a 0, combine bits into bytes, and determine the hex
value? Let the oscilloscope do it for you! Once you've set up a bus, the
MSO/DPO4000B Series will decode each packet on the bus, and display
the value in hex, binary, decimal (USB, Ethernet, MIL-STD-1553, LIN,
and FlexRay only), signed decimal (I2S/LJ/RJ/TDM only), or ASCII (USB,
Ethernet, and RS-232/422/485/UART only) in the bus waveform.
Event Table
In addition to seeing decoded packet data on the bus waveform itself, you
can view captured packets in a tabular view much like you would see in a
software listing. Packets are time stamped and listed consecutively with
columns for each component (Address, Data, etc.). Event table data can be
saved to .csv format.
Search
Serial triggering is very useful for isolating the event of interest, but once
you've captured it and need to analyze the surrounding data, what do
you do? In the past, users had to manually scroll through the waveform
counting and converting bits and looking for what caused the event. With
the MSO/DPO4000B Series, you can have the oscilloscope automatically
search through the acquired data for user-dened criteria including serial
packet content. Each occurrence is highlighted by a search mark. Rapid
navigation between marks is as simple as pressing the Previous ()and
Next () buttons on the front panel.
www.tektronix.com 7
Data Sheet
Safe operating area measurement. Automated power measurements enable quick and
accurate analysis of common power parameters.
Limit Test showing a mask created from a golden waveform and compared against a live
signal. Results showing statistical information about the test are displayed.
Power Analysis (Optional)
Ever increasing consumer demand for longer battery-life devices and for
green solutions that consume less power require power-supply designers
to characterize and minimize switching losses to improve efciency. In
addition, the supply's power levels, output purity, and harmonic feedback
into the power line must be characterized to comply with national and
regional power quality standards. Historically, making these and many
other power measurements on an oscilloscope has been a long, manual,
and tedious process. The MSO/DPO4000B Series optional power analysis
tools greatly simplify these tasks, enabling quick and accurate analysis
of power quality, switching loss, harmonics, safe operating area (SOA),
modulation, ripple, and slew rate (di/dt, dv/dt). Completely integrated into
the oscilloscope, the power analysis tools provide automated, repeatable
power measurements with a touch of a button; no external PC or complex
software setup is required.
Limit/Mask Testing (Optional)
A common task during the development process is characterizing the
behavior of certain signals in a system. One method, called limit testing,
is to compare a tested signal to a known good or "golden" version of the
same signal with user-dened vertical and horizontal tolerances. Another
common method, called mask testing, is to compare a tested signal to
a mask, looking for where a signal under test violates the mask. The
MSO/DPO4000B Series offers both limit and mask testing capability useful
for long-term signal monitoring, characterizing signals during design, or
testing on a production line. A robust set of telecommunications and
computer standards are provided to test for compliance to a standard.
Additionally, custom masks can be created and used for characterizing
signals. Tailor a test to your specicrequirementsbydening test duration
in number of waveforms or time, a violation threshold that must be met
before considering a test a failure, counting hits along with statistical
information, and actions upon violations, test failure, and test complete.
Whether specifying a mask from a known good signal or from a custom or
standard mask, conducting pass/fail tests in search of waveform anomalies
such as glitches has never been easier.
Video Design and Development
Many video engineers have remained loyal to analog oscilloscopes,
believing the intensity gradations on an analog display are the only way
to see certain video waveform details. The MSO/DPO4000B Series fast
waveform capture rate, coupled with its intensity-graded view of the signal,
provides the same information-rich display as an analog oscilloscope, but
with much more detail and all the benets of digital oscilloscopes.
Standard features such as IRE and mV graticules, holdoff by elds, video
polarity, and an Autoset smart enough to detect video signals, make the
MSO/DPO4000B Series the easiest to use oscilloscope on the market for
video applications. And with up to a 1 GHz bandwidth and four analog
inputs, the MSO/DPO4000B Series provides ample performance for analog
and digital video use.
The MSO/DPO4000B Series video functionality is further extended with
the optional DPO4VID video application module. DPO4VID provides the
industry's most complete suite of HDTV and custom (nonstandard) video
triggers.
8www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
The MSO/DPO4000B Series is designed to make your work easier. The large,
high-resolution display shows intricate signal details. Dedicated front-panel controls
simplify operation. Two USB host ports on the front panel allow you to easily transfer
screenshots, instrument settings, and waveform data to a USB thumb drive.
Designed to Make Your Work Easier
Large, High-resolution Display
The MSO/DPO4000B Series features a 10.4 in. (264 mm) bright, LED
backlit XGA color display for seeing intricate signal details.
Dedicated Front-panel Controls
Per-channel vertical controls provide simple and intuitive operation. No
longer do you need to share one set of vertical controls across all four
channels.
Connectivity
Two USB host ports on the front panel enable easy transfer of screenshots,
instrument settings, and waveform data to a USB thumb drive. The rear
panel contains two additional USB host ports and a USB device port for
controlling the oscilloscope remotely from a PC or for connecting a USB
keyboard. The USB device port can also be used to print directly to a
PictBridge®-compatible printer. An integrated 10/100/1000BASE-T Ethernet
port enables easy connection to networks and a Video Out port allows the
oscilloscope display to be exported to an external monitor or projector. The
instrument can mount external network drives for easy storage of screen
images, setup les, or data les. Setup or data les can then be directly
recalled and loaded into the oscilloscope from the network drive location.
The MSO/DPO4000B Series is LXI Class-C compliant.
Compact Form Factor
Acomp
act, portable form factor allows the MSO/DPO4000B Series to be
easily moved between labs and, with a depth of just 5.8 in. (147 mm), it
saves you valuable space on your test bench.
The MSO/DPO4000B Series' compact form factor frees up valuable space on your bench
or desktop.
TekVPI probe interface simplies connecting your probes to the oscilloscope.
TekVPI®Probe Interface
The TekVPI probe interface sets the standard for ease of use in probing.
In addition to the secure, reliable connection that the interface provides,
TekVPI probes feature status indicators and controls, as well as a probe
menu button right on the compensation box itself. This button brings up
a probe menu on the oscilloscope display with all relevant settings and
controls for the probe. The TekVPI interface enables direct attachment of
current probes without requiring a separate power supply. TekVPI probes
can be controlled remotely through USB, GPIB, or LAN, enabling more
versatile solutions in ATE environments.
www.tektronix.com 9
Data Sheet
OpenChoice®Desktop software enables seamless connection between the oscilloscope
and your PC.
Extended Analysis
Acquiring data and measurements from the MSO/DPO4000B Series is as
simple as connecting a USB cable from the oscilloscope to your PC. Key
software applications NI LabVIEW SignalExpress™ Tektronix Edition,
OpenChoice®Desktop, and Microsoft Excel and Word toolbars are
included standard with each oscilloscope to enable fast and easy direct
communication with your Windows PC.
NI LabVIEW SignalExpress Tektronix Edition enables you to instantly
acquire, generate, analyze, compare, import, and save measurement data
and signals using an intuitive drag-and-drop user interface that does not
require any programming. The optional Professional Version offers over
200 built-in functions that provide additional signal processing, advanced
analysis, sweeping, and user-dened step capabilities.
The LXI web interface provides access to network settings, enables remote instrument
control and is accessible from any standard web browser.
For simple tasks, the included OpenChoice Desktop enables fast and easy
communication between the oscilloscope and your PC through USB or LAN
for transferring settings, waveforms, and screen images.
The MSO/DPO4000B Series can also be connected to your network using
the LAN port. The included LXI web interface provides information about
the current conguration of your MSO/DPO4000B Series oscilloscope,
including network conguration. The LXI web interface also provides remote
instrument control through the popular e*Scope web-based instrument
control capability. You can make changes to the network conguration,
control instrument settings, save screen images and instrument data, and
save/load instrument setups of your MSO/DPO4000B Series oscilloscope
directly from the web interface through a password-protected web page.
10 www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
Characteristics
Vertical System Analog Channels
Characteristic DPO4034B
MSO4034B
DPO4054B
MSO4054B
DPO4104B
MSO4104B
Input Channels 4
Analog Bandwidth (–3 dB) 5 mV/div -
1V/div
350 MHz 500 MHz 1GHz
Calculated Rise Time 5 mV/div (typical) 1 ns 700 ps 350 ps
Hardware Bandwidth Limits 20 MHz or 250 MHz
Input Coupling AC, DC
Input Impedance 1M±1%, 50 ±1%
Input Sensitivity, 1 M1mV/divto10V/div
Input Sensitivity, 50 1mV/divto1V/div
Vertical Resolution 8 bits (11 bits with Hi Res)
Max Input Voltage, 1 M300 VRMS CAT II with peaks ±425 V
Max Input Voltage, 50 5V
RMS with peaks < ±20 V
DC Gain Accuracy ±1.5%, derated at 0.10%/°C above 30 °C
Channel-to-Channel Isolation 100:1 at 100 MHz and 30:1 at >100 MHz up to the rated bandwidth for any two channels having equal volts/div settings
Offset Range
Range 1M50
1mV/divto50mV/div ±1 V ±1 V
50.5 mV/div to
99.5 mV/div
±0.5 V ±0.5 V
100 mV/div to 500 mV/div ±10V ±10V
505 mV/div to 995 mV/div ±5 V ±5 V
1V/divto5V/div ±100 V ±5 V
5.05 V/div to 10 V/div ±50 V NA
Vertical System Digital Channels
Characteristic All MSO4000B Models
Input Channels 16 Digital (D15 - D0)
Thresholds Per-channel Thresholds
Threshold Selections TTL, CMOS, ECL, PECL, User Dened
User-dened Threshold
Range
±40 V
Maximum Input Voltage ±42 Vpeak
Threshold Accuracy ±(100 mV + 3% of threshold setting)
Input Dynamic Range 30 Vp-p 200 MHz
10 Vp-p >200 MHz
Minimum Voltage Swing 400 mV
Input Impedance 100 k
Probe Loading 3 pF
Vertical Resolution 1 bit
Horizontal System Analog Channels
Characteristic DPO4034B
MSO4034B
DPO4054B
MSO4054B
DPO4104B
MSO4104B
Maximum Sample
Rate (All channels)
2.5 GS/s 2.5 GS/s 5 GS/s
Maximum
Record Length
(All channels)
20M points
Maximum Duration
at Highest Sample
Rate (All channels)
8ms 8ms 4ms
Time Base Range 1 ns to 1,000 s 400 ps to 1,000 s
Time Base Delay
Time Range
–10 divisions to 5000 s
Channel-to-Channel
Deskew Range
±125 ns
Time Base
Accuracy
±5 ppm over any 1 ms interval
Horizontal System Digital Channels
Characteristic All MSO4000B Models
Maximum Sample Rate
(Main)
500 MS/s (2 ns resolution)
Maximum Record Length
(Main)
20M points
Maximum Sample Rate
(MagniVu)
16.5 GS/s (60.6 ps resolution)
Maximum Record Length
(MagniVu)
10k points centered around the trigger
Minimum Detectable
Pulse Width (Typical)
1ns
Channel-to-Channel
Skew (Typical)
200 ps
Maximum Input Toggle
Rate
500 MHz
Maximum frequency sine wave that can accurately be
reproduced as a logic square wave. Requires the use
of a short ground extender on each channel.
This is the maximum frequency at the minimum swing
amplitude. Higher toggle rates can be achieved with
higher amplitudes.
www.tektronix.com 11
Data Sheet
Trigger System
CharacteristicDescription
Main Trigger Modes Auto, Normal, and Single
Trigger Coupling DC, AC, HF reject (attenuates >50 kHz), LF
reject (attenuates <50 kHz), noise reject (reduces
sensitivity)
Trigger Holdoff
Range
20nsto8s
Trigger Sensitivity
Characteristic Description
Internal DC Coupled
1MPath
(All models)
50 Path
(MSO/DPO4054B,
MSO/DPO4034B)
For 1 mV/div to 4.98 mV/div; 0.75 div from DC to
50 MHz, increasing to 1.3 div at rated bandwidth
For 5 mV/div; 0.4 div from DC to 50 MHz,
increasing to 1 div at rated bandwidth
50 Path
(MSO/DPO4104B)
0.4 div from DC to 50 MHz, increasing to 1 div at
rated bandwidth
External
Auxiliary Input 200 mV from DC to 50 MHz, increasing to 500 mV
at rated bandwidth
Trigger Level Range
CharacteristicDescription
Any Channel ±8 divisions from center of screen
External
(Auxiliary Input)
±8 V
Line Fixed at about 50% of line voltage
Trigger Frequency Readout
Provides 6-digit frequency readout of triggerable events.
Trigger Modes
Mode Description
Edge Positive or negative slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and noise reject
Sequence (B-trigger) Trigger Delay by Time 4 ns to 8 s. Or Trigger Delay by Events 1 to 4,000,000 events
Pulse Width Trigger on width of positive or negative pulses that are >, <, =, or aspecied period of time (4 ns to 8 s)
Timeout Trigger when no pulse is detected within a specied time (4 ns to 8 s)
Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the rst again
Logic Trigger when any logical pattern of channels goes false or stays true for specied period of time (4 ns to 8 s). Any input can be used as a clock to
look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specied for all analog and digital input channels dened as High, Low, or
Don't Care
Setup and Hold Trigger on violations of both setup time and hold time between clock and data present on any of the input channels
Rise/Fall Time Trigger on pulse edge rates that are faster or slower than specied. Slope may be positive, negative, or either
Video Trigger on all lines, odd, even, or all elds on NTSC, PAL, and SECAM video signals
Extended Video
(Optional)
Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30, 1080p/50,
1080p/60, and custom bi-level and tri-level sync video standards
I2C (Optional) Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses up to 10 Mb/s
SPI (Optional) Trigger on SS active, MOSI, MISO, or MOSI and MISO on SPI buses up to 50 Mb/s
12 www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
Mode Description
Low-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token packet trigger Any token type, SOF, OUT, IN, SETUP; Address can be specied for Any Token, OUT, IN, and SETUP token types. Address
can be further specied to trigger on ,<,=,>,,a particular value, or inside or outside of a range. Frame number can be specied for
SOF token using binary, hex, unsigned decimal and don't care digits.
Data packet trigger Any data type, DATA0, DATA1; Data can be further specied to trigger on ,<,=,>,,a particular data value, or inside
or outside of a range.
Handshake packet trigger Any handshake type, ACK, NAK, STALL.
Special packet trigger Any special type, Reserved.
Error trigger PID Check, CRC5 or CRC16, Bit Stufng.
Full-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token packet trigger Any token type, SOF, OUT, IN, SETUP; Address can be specied for Any Token, OUT, IN, and SETUP token types. Address
can be further specied to trigger on ,<,=,>,,a particular value, or inside or outside of a range. Frame number can be specied for
SOF token using binary, hex, unsigned decimal and don't care digits.
Data packet trigger Any data type, DATA0, DATA1; Data can be further specied to trigger on ,<,=,>,,a particular data value, or inside
or outside of a range.
Handshake packet trigger Any handshake type, ACK, NAK, STALL.
Special packet trigger Any special type, PRE, Reserved.
Error trigger PID Check, CRC5 or CRC16, Bit Stufng.
USB (Optional)
High-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special
Packet, Error.
Token packet trigger Any token type, SOF, OUT, IN, SETUP; Address can be specied for Any Token, OUT, IN, and SETUP token types. Address
can be further specied to trigger on ,<,=,>,,a particular value, or inside or outside of a range. Frame number can be specied for
SOF token using binary, hex, unsigned decimal and don't care digits.
Data packet trigger Any data type, DATA0, DATA1, DATA2, DATAM; Data can be further specied to trigger on ,<,=,>,,aparticular
data value, or inside or outside of a range.
Handshake packet trigger Any handshake type, ACK, NAK, STALL, NYET.
Special packet trigger Any special type, ERR, SPLIT, PING, Reserved. SPLIT packet components that can be specied include:
Hub Address
Start/Complete Don't Care, Start (SSPLIT), Complete (CSPLIT)
Port Address
Start and End bits Don’t Care, Control/Bulk/Interrupt (Full-speed Device, Low-speed Device), Isochronous (Data is Middle, Data is End,
Data is Start, Data is All)
Endpoint Type Don’t Care, Control, Isochronous, Bulk, Interrupt
Error trigger PID Check, CRC5 or CRC16, Any.
High-speed support only available on MSO4104B and DPO4104B models.
10BASE-T: Trigger on Start Frame Delimiter, MAC Addresses, MAC Q-Tag Control Information, MAC Length/Type, IP Header, TCP Header,
TCP/IPv4/MAC Client Data, End of Packet, FCS (CRC) Error.
MAC Addresses Trigger on Source and Destination 48-bit address values.
MAC Q-Tag Control Information Trigger on Q-Tag 32-bit value.
MAC Length/Type Trigger on ,<,=,>,,a particular 16-bit value, or inside or outside of a range.
IP Header Trigger on IP Protocol 8-bit value, Source Address, Destination Address.
TCP Header Trigger on Source Port, Destination Port, Sequence Number, and Ack Number.
TCP/IPv4/MAC Client Data Trigger on ,<,=,>,,a particular data value, or inside or outside of a range. Selectable number of bytes
to trigger on from 1-16. Byte offset options of Don't Care, 0-1499.
Ethernet (Optional)
100BASE-TX: Trigger on Start Frame Delimiter, MAC Addresses, MAC Q-Tag Control Information, MAC Length/Type, IP Header, TCP Header,
TCP/IPv4/MAC Client Data, End of Packet, FCS (CRC) Error, Idle.
MAC Addresses Trigger on Source and Destination 48-bit address values.
MAC Q-Tag Control Information Trigger on Q-Tag 32-bit value.
MAC Length/Type Trigger on ,<,=,>,,a particular 16-bit value, or inside or outside of a range.
IP Header Trigger on IP Protocol 8-bit value, Source Address, Destination Address.
TCP Header Trigger on Source Port, Destination Port, Sequence Number, and Ack Number.
TCP/IPv4/MAC Client Data Trigger on ,<,=,>,,a particular data value, or inside or outside of a range. Selectable number of bytes
to trigger on from 1-16. Byte offset options of Don't Care, 0-1499.
CAN (Optional) Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identier (standard or extended), Data, Identier and Data, End of Frame,
Missing ACK, or Bit Stufng Error on CAN signals up to 1 Mb/s. Data can be further specied to trigger on ,<,=,>,,oraspecic data value.
User-adjustable sample point is set to 50% by default
LIN (Optional) Trigger on Sync, Identier, Data, Identier and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum Errors up to 100 Kb/s
(by LIN denition, 20 Kb/s)
FlexRay (Optional) Trigger on Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identier, Cycle Count, Complete Header Field, Data, Identier and
Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame Errors up to 100 Mb/s
RS-232/422/485/UART
(Optional)
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error up to 10 Mb/s
www.tektronix.com 13
Data Sheet
Mode Description
MIL-STD-1553
(Optional)
Trigger on Sync, Word Type*1(Command, Status, Data), Command Word*1(set RT Address, T/R, Sub-address/Mode, Data Word Count/Mode Code,
and Parity individually), Status Word*1(set RT Address, Message Error, Instrumentation, Service Request Bit, Broadcast Command Received, Busy,
Subsystem Flag, Dynamic Bus Control Acceptance (DBCA), Terminal Flag, and Parity individually), Data Word (user-specied 16-bit data value),
Error (Sync, Parity, Manchester, Non-contiguous data), Idle Time (minimum time selectable from 4 µs to 100 µs; maximum time selectable from
12 µs to 100 µs; trigger on < minimum, > maximum, inside range, outside range). RT Address can be further specied to trigger on =, ,<,>,,
a particular value, or inside or outside of a range.
I2S/LJ/RJ/TDM
(Optional)
Trigger on Word Select, Frame Sync, or Data. Data can be further specied to trigger on ,<,=,>,,aspecic data value, or inside or outside of
a range
Maximum data rate for I2S/LJ/RJ is 12.5 Mb/s
Maximum data rate for TDM is 25 Mb/s
Parallel (Available on
MSO models only)
Trigger on a parallel bus data value. Parallel bus can be from 1 to 20 bits in size. Binary and Hex radices are supported
*1Trigger selection of Command Word will trigger on Command and ambiguous Command/Status words. Trigger selection of Status Word will trigger on Status and ambiguous Command/Status words.
Acquisition Modes
Mode Description
Sample Acquire sampled values
Peak Detect Captures glitches as narrow as 800 ps (1 GHz
models) or 1.6 ns (500 MHz and 350 MHz models)
at all sweep speeds
Averaging From 2 to 512 waveforms included in average
Envelope Min-Max envelope reecting Peak Detect data over
multiple acquisitions
Hi Res Real-time boxcar averaging reduces random noise
and increases vertical resolution
Roll Scrolls waveforms right to left across the screen at
sweep speeds slower than or equal to 40 ms/div
Waveform Measurements
Measurement Description
Cursors Waveform and Screen
Automatic
Measurements
29, of which up to eight can be displayed
on-screen at any one time. Measurements include:
Period, Frequency, Delay, Rise Time, Fall Time,
Positive Duty Cycle, Negative Duty Cycle, Positive
Pulse Width, Negative Pulse Width, Burst Width,
Phase, Positive Overshoot, Negative Overshoot,
Peak-to-Peak, Amplitude, High, Low, Max, Min,
Mean, Cycle Mean, RMS, Cycle RMS, Positive
Pulse Count, Negative Pulse Count, Rising Edge
Count, Falling Edge Count, Area and Cycle Area
Measurement
Statistics
Mean, Min, Max, Standard Deviation
Reference Levels User-denable reference levels for automatic
measurements can be specied in either percent
or units
Gating Isolate the specic occurrence within an acquisition
to take measurements on, using either the screen
or waveform cursors
Waveform Histogram A waveform histogram provides an array of data
values representing the total number of hits
inside of a user-denedregionofthedisplay. A
waveform histogram is both a visual graph of the
hit distribution as well as a numeric array of values
that can be measured.
Sources Channel 1, Channel 2, Channel 3,
Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math
Types Vertical, Horizontal
Waveform Histogram
Measurements
Waveform Count, Hits in Box, Peak Hits, Median,
Max, Min, Peak-to-Peak, Mean, Standard
Deviation, Sigma 1, Sigma 2, Sigma 3
Waveform Math
Characteristic Description
Arithmetic Add, subtract, multiply, and divide waveforms
Math Functions Integrate, Differentiate, FFT
Spectral magnitude
FFT Vertical Scale: Linear RMS or dBV RMS
FFT
FFT Window Settings: Rectangular, Hamming,
Hanning, Blackman Harris
Advanced Math Dene extensive algebraic expressions including
waveforms, reference waveforms, math functions.
Perform math on math using complex equations
(FFT, Intg, Diff, Log, Exp, Sqrt, Abs, Sine,
Cosine, Tangent, Rad, Deg), scalars, up to two
user-adjustable variables and results of parametric
measurements (Period, Freq, Delay, Rise,
Fall, PosWidth, NegWidth, BurstWidth, Phase,
PosDutyCycle, NegDutyCycle, PosOverShoot,
NegOverShoot, PeakPeak, Amplitude, RMS,
CycleRMS, High, Low, Max, Min, Mean,
CycleMean, Area, CycleArea, and trend plots)
e.g. (Intg(Ch1–Mean(Ch1))×1.414×VAR1)
Power Measurements (Optional)
Measurement Description
Power Quality
Measurements
VRMS,V
Crest Factor,Frequency,I
RMS,I
Crest Factor,True
Power, Apparent Power, Reactive Power, Power
Factor, Phase Angle
Power Loss: Ton,T
off, Conduction, TotalSwitching Loss
Measurements Energy Loss: Ton,T
off, Conduction, Total
THD-F, THD-R, RMS measurements
Graphical and table displays of harmonics
Harmonics
Test to IEC61000-3-2 Class A and MIL-STD-1399
Section 300A
Ripple
Measurements
Vripple and Iripple
Modulation Analysis Graphical display of +Pulse Width, –Pulse Width,
Period, Frequency, +Duty Cycle, and –Duty Cycle
modulation types
Safe Operating Area Graphical display and mask testing of switching
device safe operatingareameasurements
dV/dt and dI/dt
Measurements
Cursor measurements of slew rate
14 www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
Limit/Mask Testing (Optional)
Characteristic Description
Included Standard Masks ITU-T, ANSI T1.102, USB
Test Source Limit Test: Any Ch1 - Ch4 or any R1 - R4
Mask Test: Any Ch1 - Ch4
Limit test vertical tolerance from 0 to 1 division in 1 m
division increments; Limit test horizontal tolerance from
0 to 500 m division in 1 m division increments
Load standard mask from internal memory
Mask Creation
Load custom mask from text le with up to 8 segments
Mask Scaling Lock to Source ON (mask automatically re-scales with
source-channel settings changes)
Lock to Source OFF (mask does not re-scale with
source-channel settings changes)
Test Criteria Run Until Minimum number of waveforms (from 1 to 1,000,000;
Innity)
Minimum elapsed time (from 1 second to 48 hours;
Innity)
Violation Threshold From 1 to 1,000,000
Actions on Test Failure Stop acquisition, save screen image to le, save
waveform to le, print screen image, trigger out pulse,
set remote interface SRQ
Actions on Test Complete Trigger out pulse, set remote interface SRQ
Results Display Test status, total waveforms, number of violations,
violation rate, total tests, failed tests, test failure rate,
elapsed time, total hits for each mask segment
Software
Software Description
NI LabVIEW
SignalExpress Tektronix
Edition
A fully interactive measurement software environment
optimized for the MSO/DPO4000B Series, enables
you to instantly acquire, generate, analyze, compare,
import, and save measurement data and signals using
an intuitive drag-and-drop user interface that does not
require any programming.
Standard MSO/DPO4000B Series support for
acquiring, controlling, viewing, and exporting your
live signal data is permanently available through
the software. The full version (SIGEXPTE) adds
additional signal processing, advanced analysis, mixed
signal, sweeping, limit testing, and user-dened step
capabilities and is available for a 30-day trial period
standard with each instrument.
OpenChoice®Desktop Enables fast and easy communication between a
Windows PC and the MSO/DPO4000B Series, using
USB or LAN. Transfer and save settings, waveforms,
measurements, and screen images. Included Word
and Excel toolbars automate the transfer of acquisition
data and screen images from the oscilloscope into
Word and Excel for quick reporting or further analysis.
IVI Driver Provides a standard instrument programming
interface for common applications such as LabVIEW,
LabWindows/CVI, Microsoft .NET and MATLAB.
e*Scope®Web-based
Remote Control
Enables control of the MSO/DPO4000B Series over a
network connection through a standard web browser.
Simply enter the IP address or network name of the
oscilloscope and a web page will be served to the
browser.
LXI Class C
Web Interface
Connect to the MSO/DPO4000B Series through
a standard web browser by simply entering the
oscilloscope's IP address or network name in the
address bar of the browser. The web interface enables
viewing of instrument status and conguration, status
and modication of network settings, and instrument
control through the e*scope web-based remote
control. All web interaction conforms to LXI Class C
specication.
Display Characteristics
Characteristic Description
Display Type 10.4 in. (264 mm) liquid-crystal TFT color display
Display Resolution 1,024 horizontal × 768 vertical pixels (XGA)
Waveform Styles Vectors, Dots, Variable Persistence, Innite
Persistence
Graticules Full, Grid, Solid, CrossHair,Frame,IRE,andmV
Format YT and simultaneous XY/YT
Waveform Capture Rate >50,000 wfm/s maximum
Input/Output Ports
Port Description
USB 2.0 High-speed Host
Port
Supports USB mass storage devices, printers and
keyboard. Two ports on front and two ports on rear of
instrument
USB 2.0 Device Port Rear-panel connector allows for communication/control
of oscilloscope through USBTMC or GPIB
(with a TEK-USB-488), and direct printing to all
PictBridge-compatible printers
LAN Port RJ-45 connector, supports 10/100/1000 Mb/s
XGA Video Port DB-15 female connector, connect to show the
oscilloscope display on an external monitor or projector
Auxiliary Input Front-panel BNC connector. Input Impedance 1 M.
Max input 300 VRMS CAT II with peaks ±425 V
Probe Compensator
Output
Front-panel pins
Amplitude: 2.5 V
Frequency: 1 kHz
Auxiliary Out Rear-panel BNC connector
VOUT (Hi): 2.5 V open circuit, 1.0 V 50 to ground
VOUT (Lo): 0.7Vintoaloadof4mA;0.25 V 50
to ground
Outputcanbecongured to provide a pulse out signal
when the oscilloscope triggers, the internal oscilloscope
reference clock out, or an event out for limit/mask
testing
External Reference In Time-base system can phase lock to an external
10 MHz reference (10 MHz ±1%)
Kensington Lock Rear-panel security slot connects to standard
Kensington lock
VESA Mount Standard (MIS-D 100) 100 mm VESA mounting points
on rear of instrument
LAN eXtensions for Instrumentation (LXI)
Characteristic Description
Class LXI Class C
Version V1.3
Power Source
Characteristic Description
Power Source Voltage 100 to 240 V ±10%
Power Source Frequency 45 to 66 Hz (85 to 264 V)
360 to 440 Hz (100 to 132 V)
Power Consumption 225 W maximum
www.tektronix.com 15
Data Sheet
Physical Characteristics
Dimensions mm in.
Height 229 9.0
Width 439 17.3
Depth 147 5.8
Weight kg lb.
Net 511
Shipping 10.7 23.6
Rackmount Conguration 5U
Cooling Clearance 2 in. (51 mm) required on left side and rear of
instrument
Environmental
Characteristic Description
Temperature
Operating 0 ºC to +50 ºC
Nonoperating 2Cto+6C
Humidity
Operating High: 40 ºC to 50 ºC, 10% to 60% Relative Humidity
Low:Cto4C,10%to90%RelativeHumidity
Nonoperating High: 40 ºC to 60 ºC, 5% to 60% Relative Humidity
Low: 0 ºC to 40 ºC, 5% to 90% Relative Humidity
Altitude
Operating 9,843 ft. (3,000 m)
Nonoperating 30,000 ft. (9,144 m)
Regulatory
Electromagnetic
Compatibility
EC Council Directive 2004/108/EC
Safety UL61010-1, Second Edition; CSA61010-1 Second
Edition, EN61010-1:2001; IEC 61010-1:2001
Ordering Information
MSO/DPO4000B Family
Model Description
DPO4000B Models
DPO4034B 350 MHz, 2.5 GS/s, 20M record length,
4-channel digital phosphor oscilloscope
DPO4054B 500 MHz, 2.5 GS/s, 20M record length,
4-channel digital phosphor oscilloscope
DPO4104B 1 GHz, 5 GS/s, 20M record length,
4-channel digital phosphor oscilloscope
MSO4000B Models
MSO4034B 350 MHz, 2.5 GS/s, 20M record length,
4+16 channel mixed signal oscilloscope
MSO4054B 500 MHz, 2.5 GS/s, 20M record length,
4+16 channel mixed signal oscilloscope
MSO4104B 1 GHz, 5 GS/s, 20M record length,
4+16 channel mixed signal oscilloscope
All Models Include: One passive voltage probe per analog channel (TPP0500
500 MHz, 10X, 3.9 pF for 500 MHz and 350 MHz models; TPP1000 1 GHz, 10X,
3.9 pF for 1 GHz models), Front Cover (200-5130-xx), User Manual (071-2810-xx),
Documentation CD (063-4300-xx), OpenChoice®Desktop Software, NI LabVIEW
SignalExpress™ Tektronix Edition Software, Calibration Certicates document
measurement traceability to National Metrology Institute(s) the Quality System
this product is manufactured in is ISO9001 registered, power cord, accessory bag
(016-2030-xx) and a three-year warranty. Please specify power plug and manual
language version when ordering.
MSO Models also Include: One P6616 16-channel logic probe and a logic probe
accessory kit (020-2662-xx).
16 www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
Application Modules
Application modules have licenses which can be transferred between an application
module and an oscilloscope. The license may be contained in the module; allowing
the module to be moved from one instrument to another. Or, the license can be
contained in the oscilloscope; allowing the module to be removed and stored for
safekeeping. Transferring the license to an oscilloscope and removing the module
permits the use of more than 4 applications simultaneously.
Module Description
DPO4AERO Aerospace Serial Triggering and Analysis Module.
Enables triggering on packet-level information on
MIL-STD-1553 buses as well as analytical tools
such as digital views of the signal, bus views, packet
decoding, search tools, and packet decode tables with
time-stamp information.
Signal Inputs Any Ch1 - Ch4, Math, Ref1 - Ref4
Recommended Probing Differential or single ended
(only one single-ended signal required)
DPO4AUDIO Audio Serial Triggering and Analysis Module. Enables
triggering on packet-level information on I2S, LJ, RJ,
and TDM audio buses as well as analytical tools
such as digital views of the signal, bus views, packet
decoding, search tools, and packet decode tables with
time-stamp information.
Signal Inputs Any Ch1 - Ch4 (and any D0 - D15 on
MSO models)
Recommended Probing I2S, LJ, RJ, TDM: Single
ended
DPO4AUTO Automotive Serial Triggering and Analysis Module.
Enables triggering on packet-level information on CAN
and LIN buses as well as analytical tools such as
digital views of the signal, bus views, packet decoding,
search tools, and packet decode tables with time-stamp
information.
Signal Inputs LIN: Any Ch1 - Ch4 (and any D0 - D15
on MSO models); CAN: Any Ch1 - Ch4 (and any D0 -
D15 on MSO models; single-ended probing only)
Recommended Probing LIN: Single ended; CAN:
Single ended or differential
DPO4AUTOMAX Extended Automotive Serial Triggering and Analysis
Module. Enables triggering on packet-level information
on CAN, LIN, and FlexRay buses as well as analytical
tools such as digital views of the signal, bus views,
packet decoding, search tools, packet decode tables
with time-stamp information, and eye diagram analysis
software.
Signal Inputs LIN: Any Ch1 - Ch4 (and any D0 - D15
on MSO models); CAN: Any Ch1 - Ch4 (and any D0
- D15 on MSO models; single-ended probing only);
FlexRay: Any Ch1 - Ch4 (and any D0 - D15 on MSO
models; single-ended probing only)
Recommended Probing LIN: Single ended; CAN,
FlexRay: Single ended or differential
Module Description
DPO4COMP Computer Serial Triggering and Analysis Module.
Enables triggering on packet-level information on
RS-232/422/485/UART buses as well as analytical
tools such as digital views of the signal, bus views,
packet decoding, search tools, and packet decode
tables with time-stamp information.
Signal Inputs Any Ch1 - Ch4 (and any D0 - D15 on
MSO models; single-ending probing only)
Recommended Probing RS-232/UART: Single ended;
RS-422/485: Differential
DPO4EMBD Embedded Serial Triggering and Analysis Module.
Enables triggering on packet-level information on I2C
and SPI busesaswellasanalyticaltoolssuchas
digital views of the signal, bus views, packet decoding,
search tools, and packet decode tables with time-stamp
information.
Signal Inputs I2C: Any Ch1 - Ch4 (and any D0 - D15
on MSO models); SPI: Any Ch1 - Ch4 (and any D0 -
D15onMSOm
odels)
Recommended Probing I2C, SPI: Single ended
DPO4ENET Ethernet Serial Triggering and Analysis Module.
Enables triggering on packet-level information on
10BASE-T and 100BASE-TX buses as well as
analytical tools such as digital views of the signal,
bus views, packet decoding, search tools, and packet
decode tables with time-stamp information.
Signal Inputs Any Ch1 - Ch4 for single-ended
probing; Any Ch1 - Ch4, Math, Ref1 - Ref4 for
differential probing
Recommended Probing 10BASE-T: Single ended or
differential; 100BASE-TX: Differential
DPO4USB USB Serial Triggering and Analysis Module. Enables
triggering on packet-level content for low-speed,
full-speed, and high-speed USB serial buses. Also
enables analytical tools such as digital views of the
signal, bus views, packet decoding, search tools, and
packet decode tables with time-stamp information for
low-speed, full-speed, and high-speed USB serial
buses.
Signal Inputs Low-speed and Full-speed: Any
Ch1-Ch4(andanyD0-D15onMSOmodels;for
single-ending probing only); Low-speed, Full-speed,
and High-speed: Any Ch1 - Ch4, Math, Ref1 - Ref4
Recommended Probing Low-speed and Full-speed:
Single ended or differential; High-speed: Differential
USB high-speed supported only on MSO4104B and
DPO4104B models
DPO4PWR Power Analysis Application Module. Enables quick
and accurate analysis of power quality, switching loss,
harmonics, safe operating area (SOA), modulation,
ripple, and slew rate (dI/dt, dV/dt)
DPO4LMT Limit and Mask Testing Application Module. Enables
testing against limit templates generated from "golden"
waveforms and mask testing using custom or standard
telecommunications or computer masks
DPO4VID HDTV and Custom (nonstandard) Video Triggering
Module
www.tektronix.com 17
Data Sheet
Instrument Options
Power Plug Options
Option Description
Opt. A0 North America
Opt. A1 Universal Euro
Opt. A2 United Kingdom
Opt. A3 Australia
Opt. A5 Switzerland
Opt. A6 Japan
Opt. A10 China
Opt. A11 India
Opt. A12 Brazil
Opt. A99 No power cord or AC adapter
Language Options*2
Option Description
Opt. L0 English manual
Opt. L1 French manual
Opt. L2 Italian manual
Opt. L3 German manual
Opt. L4 Spanish manual
Opt. L5 Japanese manual
Opt. L6 Portuguese manual
Opt. L7 Simplied Chinese manual
Opt. L8 Traditional Chinese manual
Opt. L9 Korean manual
Opt. L10 Russian manual
Opt. L99 No manual
*2Language options include a translated front-panel overlay for the selected language(s).
Service Options*3
Option Description
Opt. C3 Calibration Service 3 years
Opt. C5 Calibration Service 5 years
Opt. D1 Calibration Data Report
Opt. D3 Calibration Data Report 3 years (with Opt. C3)
Opt. D5 Calibration Data Report 5 Years (with Opt. C5)
Opt. R5 Repair Service 5 years (including warranty)
*3Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the
datasheet of each probe and accessory model for its unique warranty and calibration terms.
Recommended Probes
Tektronix offers over 100 different probes to meet your application needs. For a
comprehensive listing of available probes, please visit www.tektronix.com/probes.
Probe Description
TPP0500 500 MHz, 10X TekVPI®passive voltage probe with
3.9 pF input capacitance
TPP0502 500 MHz, 2X TekVPI passive voltage probe with 3.9 pF
input capacitance
TPP0850 2.5 kV, 800 MHz, 50X TekVPI passive high-voltage
probe
TPP1000 1 GHz, 10X TekVPI passive voltage probe with 3.9 pF
input capacitance
TAP1500 1.5 GHz TekVPI active single-ended voltage probe
TDP1500 1.5 GHz TekVPI differential voltage probe with ±25 V
differential input voltage
TDP1000 1 GHz TekVPI differential voltage probe with ±42 V
differential input voltage
TDP0500 500 MHz TekVPI differential voltage probe with ±42 V
differential input voltage
TCP0150 20 MHz TekVPI 150 Ampere AC/DC current probe
TCP0030 120 MHz TekVPI 30 Ampere AC/DC current probe
TMDP0200 ±750 V, 200 MHz high-voltage differential probe
THDP0200 ±1.5 kV, 200 MHz high-voltage differential probe
THDP0100 ±6 kV, 100 MHz high-voltage differential probe
P5100A 2.5 kV, 500 MHz, 100X high-voltage passive probe
*4Requires TekVPI®to TekProbe BNC adapter (TPA-BNC).
Recommended Accessories
Accessory Description
077-0512-xx Service Manual (English only)
SIGEXPTE NI LabVIEW SignalExpress™ Tektronix Edition
Software (Full Version)
FPGAView-xx MSO Support for Altera and Xilinx FPGAs
TPA-BNC TekVPI-to-TekProbe BNC Adapter
TEK-USB-488 GPIB-to-USB Adapter
ACD4000B Soft Transit Case
HCTEK54 Hard Transit Case (Requires ACD4000B)
RMD5000 Rackmount Kit
TEK-DPG Deskew Pulse Generator
067-1686-xx Deskew Fixture
Warranty
Three-year warranty covering all parts and labor, excluding probes.
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix
Standard Codes and Formats.
18 www.tektronix.com
Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series
www.tektronix.com 19
Data Sheet Contact Tektronix:
ASEAN / Australasia (65) 6356 3900
Austria 00800 2255 4835*
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Belgium 00800 2255 4835*
Brazil +55(11)37597627
Canada 1 800 833 9200
Central East Europe and the Baltics +41526753777
Central Europe & Greece +41 52 675 3777
Denmark +4580881401
Finland +41526
75 3777
France 00800 2255 4835*
Germany 00800 2255 4835*
Hong Kong 400 820 5835
India 000 800 650 1835
Italy 00800 2255 4835*
Japan 81 (3) 6714 3010
Luxembourg +41526753777
Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90
Middle East, Asia, and North Africa +41 52 675 3777
The Netherlands 00800 2255 4835*
Norway 800 16098
People’s Republic of China 400 820 5835
Poland +41 52 675 3777
Portugal 80 08 12370
Republic of Korea 001 800 8255 2835
Russia & CIS +7 (495) 7484900
South Africa +41526753777
Spain 00800 2255 4835*
Sweden 00800 2255 4835*
Switzerland 00800 2255 4835*
Taiwan 886 (2) 2722 9622
United Kingdom & Ireland 00800 2255 4835*
USA 1 800 833 9200
* European toll-free number. If not accessible, call: +41 52 675 3777
Updated 10 February 2011
For Further Information. Tektronix maintains a comprehensive, constantly expanding
collection of application notes, technical briefs and other resources to help engineers working
on the cutting edge of technology. Please visit www.tektronix.com
Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
issued and pending. Information in this publication supersedes that in all previously published material.
Specication and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of
Tektroni x, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks
of their respective companies.
02 Dec 2011 3GW-20156-13
www.tektronix.com