P Series Data Sheet
100 - 195 Watt DC-DC Converters
MAR 25, 2004 revised to JUL 27, 2006 Page 1 of 5 www.power-one.com
RoHS lead-solder-exempt compliant1
Extremely slim case (4 TE), fully enclosed
Extremely low inrush current, hot swappable
Operating ambient temperature range
–40 to 71 °C
with convection cooling
Input voltage up to 150 VDC, surges up to
168 V
1 to 4 isolated outputs 3.3 to 96 VDC
Class I equipment
Model Selection
Output 1 Output 2 Output 3 Output 4 Type Type
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max Input voltage Input voltage
[VDC] [W] [W] [VDC] [W] [W] [VDC] [W] [W] [VDC] [W] [W] 16 - 36 VDC 33.6 - 75 VDC
3.3 100 132 - - - - - - - - - BP 1101-7R CP 1101-7R
5.1 122 183 - - - - - - - - - BP 1001-7R CP 1001-7R
3.3 50 66 5.1 61 91 - - - - - - BP 2101-7R CP 2101-7R
5.1 61 91 5.1 61 91 - - - - - - BP 2001-7R CP 2001-7R
12 60 96 12 60 96 - - - - - - BP 2320-7R CP 2320-7R
15 60 97 15 60 97 - - - - - - BP 2540-7R CP 2540-7R
24 60 96 24 60 96 - - - - - - BP 2660-7R CP 2660-7R
5.1 61 91 12 30 48 12 30 48 - - - BP 3020-7R CP 3020-7R
5.1 61 91 15 30 48 15 30 48 - - - BP 3040-7R CP 3040-7R
5.1 61 91 24 30 48 24 30 48 - - - BP 3060-7R CP 3060-7R
5.1 20 30 12 30 48 12 30 48 3.3 10 20 BP 4720-7R CP 4720-7R
12 30 48 12 30 48 12 30 48 12 30 48 BP 4320-7R CP 4320-7R
15 30 48 15 30 48 15 30 48 15 30 48 BP 4540-7R CP 4540-7R
24 30 48 24 30 48 24 30 48 24 30 48 BP 4660-7R CP 4660-7R
Output 1 Output 2 Output 3 Output 4 Type Type
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max Input voltage Input voltage
[VDC] [W] [W] [VDC] [W] [W] [VDC] [W] [W] [VDC] [W] [W] 40 - 100.8 VDC 66 - 150 VDC
3.3 100 132 - - - - - - - - - DP 1101-7R EP 1101-7R
5.1 122 183 - - - - - - - - - DP 1001-7R EP 1001-7R
3.3 50 66 5.1 61 91 - - - - - - DP 2101-7R EP 2101-7R
5.1 61 91 5.1 61 91 - - - - - - DP 2001-7R EP 2001-7R
12 60 96 12 60 96 - - - - - - DP 2320-7R EP 2320-7R
15 60 97 15 60 97 - - - - - - DP 2540-7R EP 2540-7R
24 60 96 24 60 96 - - - - - - DP 2660-7R EP 2660-7R
5.1 61 91 12 30 48 12 30 48 - - - DP 3020-7R EP 3020-7R
5.1 61 91 15 30 48 15 30 48 - - - DP 3040-7R EP 3040-7R
5.1 61 91 24 30 48 24 30 48 - - - DP 3060-7R EP 3060-7R
5.1 20 30 12 30 48 12 30 48 3.3 10 20 DP 4720-7R EP 4720-7R
12 30 48 12 30 48 12 30 48 12 30 48 DP 4320-7R EP 4320-7R
15 30 48 15 30 48 15 30 48 15 30 48 DP 4540-7R EP 4540-7R
24 30 48 24 30 48 24 30 48 24 30 48 DP 4660-7R EP 4660-7R
P
R
O
DU
C
T
S
E
R
V
I
C
E
P
r
odu
c
t
i
on
m
on
i
t
o
r
e
d
T
y
p
e
t
e
s
t
e
d
Features
1 The solder exemption refers to all the restricted
materials except lead in solder .
P Series Data Sheet
100 - 195 Watt DC-DC Converters
MAR 25, 2004 revised to JUL 27, 2006 Page 2 of 5 www.power-one.com
Input
Input voltage refer to selection chart
Output
Efficiency
V
i nom,
I
o nom up to 92%
Nominal output current
I
o1,2,3,4 nom
P
o1,2,3,4 nom/
V
o1,2,3,4 nom
Maximal output current
I
o1,2,3,4 max
P
o1,2,3,4 max/
V
o1,2,3,4
Voltage setting accuracy 1, 2
V
i nom,
I
o nom up to ±0.6%
V
o1,2 nom
Voltage setting accuracy 3, 4
V
i nom,
I
o nom ±2%
V
o3,4 nom
Worst case output voltage 1, 2
V
i min to
V
i max, 0 to
I
o1,2 max,
T
C min to
T
C max ±1.6%
V
o nom
Minimum output current 1, 4 in parallel configuration not required 0 A
in individual or series configuration 5%
I
o1,4 nom
Minimum output current 2, 3 in parallel configuration not required 0 A
in individual or series configuration 5%
I
o2,3 nom
Cross load reg. output 4
I
o1,4 min to
I
o1,4 max typ. 100 mΩ • (
I
o1
I
o4)
Cross load reg. output 3
I
o2,3 min to
I
o2,3 max typ. 100 mΩ • (
I
o2
I
o3)
Output voltage switching noise IEC/EN 61204, total, peak-peak typ. 0.4%
V
o nom
Common power limitation (
P
o1 +
P
o4) rectangular U/I characteristic typ. 130%
P
o max/2
(
P
o2 +
P
o3) rectangular U/I characteristic typ. 130%
P
o max/2
Protection
Input reverse polarity built-in fuse
Input undervoltage lockout typ. 90%
V
i min
Input overvoltage lockout typ. 110%
V
i max
Input transient protection varistor
Output no-load, overload and short-circuit proof
Output overvoltage transient suppressor or 2nd control loop typ. 125%
V
o nom
Overtemperature switch-off with auto restart
T
C typ. 100°C
Control
Output voltage adjustment output 1, 4 (with feature R) 60 - 110%
V
o nom
Inhibit on primary side TTL input, output disabled if left open-circuit
Status indication LEDs: In OK, Out OK
Output good signal (Out OK) isolated open-collector signal
Safety
Approvals EN 60950, UL 1950, CSA C22.2 No. 950
Class of equipment class I
Protection degree IP 40
Electric strength test voltage I/case, I/O, I/aux 2100 VDC
O/case, aux/case 2100 VDC
O/O, O/aux 500 V DC
Output 1 Output 2 Output 3 Output 4 Type
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max
V
o nom
P
o nom
P
o max Input voltage
[VDC] [W] [W] [VDC] [W] [W] [VDC] [W] [W] [VDC] [W] [W] 21.6 - 50.4 VDC
3.3 100 132 - - - - - - - - - GP 1101-7R
5.1 122 183 - - - - - - - - - GP 1001-7R
3.3 50 66 5.1 61 91 - - - - - - GP 2101-7R
5.1 61 91 5.1 61 91 - - - - - - GP 2001-7R
12 60 96 12 60 96 - - - - - - GP 2320-7R
15 60 97 15 60 97 - - - - - - GP 2540-7R
24 60 96 24 60 96 - - - - - - GP 2660-7R
5.1 61 91 12 30 48 12 30 48 - - - GP 3020-7R
5.1 61 91 15 30 48 15 30 48 - - - GP 3040-7R
5.1 61 91 24 30 48 24 30 48 - - - GP 3060-7R
5.1 20 30 12 30 48 12 30 48 3.3 10 20 GP 4720-7R
12 30 48 12 30 48 12 30 48 12 30 48 GP 4320-7R
15 30 48 15 30 48 15 30 48 15 30 48 GP 4540-7R
24 30 48 24 30 48 24 30 48 24 30 48 GP 4660-7R
P Series Data Sheet
100 - 195 Watt DC-DC Converters
MAR 25, 2004 revised to JUL 27, 2006 Page 3 of 5 www.power-one.com
EMC
Electrostatic discharge IEC/EN 61000-4-2, level 4 (8/15 kV) criterion B
Electromagnetic field IEC/EN 61000-4-3, level 3 (10 V/m) criterion A
Electr. fast transients/bursts IEC/EN 61000-4-4, input/output, level 3/4 (2/4 kV) criterion B
Surge IEC/EN 61000-4-5, input, level 2/3 (1/2 kV) criterion B
Conducted disturbances IEC/EN 61000-4-6, level 2/3 (3/10 V) criterion A
Electromagnetic emissions CISPR 22/EN 55022, conducted class B
Environmental
Operating ambient temp. (-7)
V
i nom,
P
o nom, convection cooled –25 to 71°C
Operating case temp. (-7)
V
i nom,
P
o nom /
P
o max –25 to 95°C
Storage temperature non operational –40 to 100°C
Damp heat IEC/EN 60068-2-3, 93%, 40°C 56 days
Vibration, sinusoidal IEC/EN 60068-2-6, 10 - 60/60 - 2000 Hz 0.35 mm/5 gn
Shock IEC/EN 60068-2-27, 11 ms 50 gn
Bump IEC/EN 60068-2-29, 11 ms 25 gn
Random vibration IEC/EN 60068-2-64, 20 - 500 Hz 4.9 gn rms
Options
Extended temperature range –40 to 71°C, ambient, operating -9
Out OK output excludes option i D
Current sharing T
Inhibit on output side excludes option D i
Synchronisation W
Heat Sink height 20 mm or 30 mm B1 or B3
P Series Data Sheet
100 - 195 Watt DC-DC Converters
MAR 25, 2004 revised to JUL 27, 2006 Page 4 of 5 www.power-one.com
Mechanical data
The converters are designed to be inserted into a 19" rack according to IEC 60297-3.
European
Projection
104
±0.15
70
111
20
100
127
(164
)
(19.8)
M3; 4 deep
Measuring point of
case temperature
T
C
20.32 (4 TE)
13.43
100
95
LED "Out OK" green
LED "In OK" green
(171.9)
09099
Front plate
Main
face
Rear
face
Back plate
13.22
8.14
6.4
104
94 17
= 4.5
P Series Data Sheet
100 - 195 Watt DC-DC Converters
MAR 25, 2004 revised to JUL 27, 2006 Page 5 of 5 www.power-one.com
30 26 22 18 14 10 6
S10025
32 28 24 20 16 12 8 4
32 28 24 20 16 12 4/6
30 26 22 18 14 8/10 S10051
Pinout Information
Pin P 1000 P 2000 P 3000 P 4000
4 Vo1+ Output 1 Vo1+ Output 1 Vo1+ Output 1 Vo1+ Output 1
6 Vo2+ Output 2 Vo2+ Output 2 Vo2+ Output 2
8 Vo1– Output 1 Vo1– Output 1 Vo1– Output 1 Vo1– Output 1
10 Vo2– Output 2 Vo2– Output 2 Vo2– Output 2
12 S+ Sense S1+ Sense 1 S1+ Sense 1 Vo4+ Output 4
14 S– Sense S1– Sense 1 S1– Sense 1 Vo4– Output 4
16 R Control of
V
oR1 Control of
V
o1 R1 Control of
V
o1 R1/4 Control of
V
o1/4
T1 Current sharing T1 Current sharing
18 T Current sharing S2+ Sense 2 Vo3+ Output 3 Vo3+ Output 3
20 n.c. Not connected S2– Sense 2 Vo3+ Output 3 Vo3+ Output 3
22 Out OK+ Output good Out OK+ Output good Out OK+ Output good Out OK+ Output good
i+ Inhibit second. i+ Inhibit second. i+ Inhibit second. i+ Inhibit second.
24 Out OK– Output good Out OK– Output good Out OK– Output good Out OK– Output good
i– Inhibit second. i Inhibit second. i– Inhibit second. i Inhibit second.
26 Prot. ground Prot. ground Prot. ground Prot. ground
28 i Inhibit i Inhibit i Inhibit i Inhibit
W Synchronizat. W Synchronizat. W Synchronizat. W Synchronizat.
30 Vi+ Input Vi+ Input Vi+ Input Vi+ Input
32 Vi– Input Vi– Input Vi– Input Vi– Input
Accessories
Additional external heat sinks for operation above
P
o nom or
T
A max (option B1, B3)
Front panels for 19" rack mounting in 3U or 6U configuration (Schroff/Intermas)
Mating H15 connectors with screw, solder, fast-on or press-fit terminals
Mechanical mounting supports for chassis, DIN-rail and PCB mounting
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of product s, including safety agency certifications pictured on labels, may change dependi ng on
the date manufactured. Specifications are subject to change without notice.