38
JKX Series
• Connector preparation
1 - Select the proper collet ➃and the cable
seal ➂ (see page 39).
2 - Slide protective boot ➅, the backnut ➄, the
collet ➃, the cable seal ➂, the outershell ➁
and the taper seat ➀onto the cable.
Strip end
of cable (see pg. 16)
• Contacts wiring : crimp contacts
1 - Select the proper crimping tool (see page 48)
2 - Adjust the crimping tool based on the wire
size “AWG”. (See wire size and crimp tool
settings on the back of this locator.)
3 - Crimp the contacts ➃then insert the contact
into the insulator until the clip is fully seated
and cannot be removed.
• Contacts wiring : solder contacts
Fixed solder contacts 0.5 mm and 0.7 mm Removable solder contacts from 0.9 mm to 1.3 mm
1 - Insert wire into solder cup and solder 1 - Insert wire into solder cup and solder
2 - Insert the contact into the insulator until the clip is fully seated and cannot be removed.
• Connector assembly
1 - In case of shielded cable, comb out the shield
and fold back over the tapper seat
➀
.
2 - Position 2 half bushes
➈
, making sure that the
insert key appears through the windows of one
bush.
3 - Position the taper seat
➀
on the half bushes
➈
.
4 - Position all the sub-assembly in connector
housing
➉
, making sure to keep the sub-
assembly well aligned.
5 - Screw the outershell
➁
following the torque
values on page 39. Install the cable seal
➂
and
the collet
➃
into the outershell
➁
then screw
the backnut
➄
till bottoming. Use 2 wrenches
well positionned on the flats A and B. Place a
wrench to grip flats B, use the other wrench to
tighten the backnut at the flats A following the
torque values on page 39.
6 - Install the protective boot
➅
if applicable.
Wiring and assembly
instructions :
STRAIGHT PLUG
• Cable stripping : see page 37