Parameter Limits
Input
Input Voltage Range 90-250 Vac rated
81-265 Vac operation8
Input Frequency 47 to 63Hz
Input Operating Current 1.2A rms @ 90Vac input, 50W output
Input Surge Current 25A max, cold start @ 25˚C, 250Vac
Efficiency 75% typ @ 115Vac input, full power
Output
Output Power 40W, natural convection cooling9
50W with 28CFM forced air cooling9
60W peak
Line Regulation
0.2%, Vin(min) to Vin(max)
Load Regulation
3% (V1, 20% to 100% Im)
5% (V2, V3, V4, 20% to 100% Im)
Cross Regulation
0.5% (V1, 20% to 100% Imon V2-V4)
5% (V2, V3, V4, 50% to 100% Imon V1)
Noise and Ripple 25mV max RMS, 50mV max P-P, on V1 with
full load
0.5% max RMS, 1% max P-P, on V2, V3, V4,
with full load
Parameter Limits
Output (cont’d)
Power-up Overshoot 5% max, all outputs
Transient Response V1, for 25% to 75% Imchange, 5% max
deviation, with recovery to 1% within 250µS
Hold-up time 8mS min @ 115Vac input, 50W output
Overvoltage Protection Threshold 130% typical of Vout, all outputs
Power Limit Point 130% typical of max rated power
Environmental
Operating Temperature Range 0°C to 50°C
(full power)
Operating Temperature Range 0°C to 70°C Derate linearly from full
(extended range) power at +50°C to half power at +70°C
Storage Temperature Range -25°C to +85°C
Relative Humidity Range 5% to 95%, non-condensing
Vibration 0.75G peak, 5Hz to 500Hz. Test three
orthogonal axis at 1 octave/min, 5 min dwell at
four major resonances
MTBF 280,000 hours typical calculated per MIL STD
217F at 30°C ambient
Weight 0.55 lb. (0.25 kg)
Specifications are typical at 25°C unless otherwise designated.