1www.pericom.com
03/26/2014
Features
4 Differential Channel, 2:1 Mux/DeMux
PCI Express, Gen 2 Performance, 5.0Gbps
Low Bit-to-Bit Skew , 7ps max (between '+' and '-' bits)
Low Crosstalk: -23dB@3 GHz
Low Off Isolation: -23dB@3 GHz
VDD Operating Range: +1.5V to +1.8V ±10%
ESD Tolerance: 5kV HBM I/O; 2kV HBM select pin
Low channel-to-channel skew, 35ps max
Packaging (Pb-free & Green):
– 42-contact, TQFN (ZH42)
Description
Pericom Semiconductors PI2PCIE2412 is an 8 to 4 differential
channel multiplexer/demultiplexer switch. This solution can
switch 2 full PCI Express, Gen2, lanes to one of two locations.
Using a unique design technique, Pericom has been able to
minimize the impedance of the switch such that the attenuation
observed through the switch is negligible. The unique design
technique also offers a layout targeted for PCI Express signals,
which minimizes the channel to channel skew as well as channel
to channel crosstalk as required by the PCI Express specication.
Application
Routing of PCI-Express, Gen2, signals with low signal attenuation.
Block Diagram Pin Description
Truth Table
Function SEL
AN to BNL
AN to CNH
A1-
A1+
A0-
A0+
A3-
A3+
A2-
A2+
B0+
B0-
B1+
B1-
C0+
C0-
C1+
C1-
B2+
B2-
B3+
B3-
C2+
C2-
C3+
C3-
SEL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
42 41 40 39
18 19 20 21
VDD
DNG
VDD
DNG
VDD
DNG
VDD
DNG
B0+
B0-
B1+
B1-
C0+
C0-
C1+
C1-
VDD
B2+
B2-
B3+
B3-
C2+
C2-
C3+
C3-
GND
A0+
A0-
GND
VDD
A1+
A1-
VDD
SEL
GND
A2+
A2-
VDD
GND
A3+
A3-
GND
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Differential
Channel, 2:1 Mux/DeMux Switch
14-0036
2
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
Pin Description
Pin # Pin Name I/O Description
2
3
A0+
A0– I/O Signal I/O, Channel 0, Port A
6
7
A1+
A1– I/O Signal I/O, Channel 1, Port A
11
12
A2+
A2– I/O Signal I/O, Channel 2, Port A
15
16
A3+
A3– I/O Signal I/O, Channel 3, Port A
38
37
B0+
B0− I/O Signal I/O, Channel 0, Port B
36
35
B1+
B1− I/O Signal I/O, Channel 1, Port B
29
28
B2+
B2− I/O Signal I/O, Channel 2, Port B
27
26
B3+
B3− I/O Signal I/O, Channel 3, Port B
34
33
C0+
C0– I/O Signal I/O, Channel 0, Port C
32
31
C1+
C1– I/O Signal I/O, Channel 1, Port C
25
24
C2+
C2– I/O Signal I/O, Channel 2, Port C
23
22
C3+
C3− I/O Signal I/O, Channel 3, Port C
9 SEL I Operation mode Select
(when SEL=0: AB, when SEL=1: AC
5, 8, 13,18, 20, 30,
40, 42 VDD Pwr 1.5V to 1.8V (±0.1V) Positive Supply Voltage
1, 4, 10, 14, 17, 19,
21, 39, 41, Center
Pad
GND Pwr Power ground
14-0036
3
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
Storage Temperature ....................................................–65°C to +150°C
Supply Voltage to Ground Potential ................................–0.5V to +2.5V
DC Input Voltage .............................................................. –0.5V to VDD
DC Output Current ....................................................................... 120mA
Power Dissipation ........................................................................... 0.5W
Note: Stresses greater than those listed under MAXIMUM
RATINGS may cause permanent damage to the device. This
is a stress rating only and functional operation of the device
at these or any other conditions above those indicated in the
operational sections of this specication is not implied. Expo-
sure to absolute maximum rating conditions for extended
periods may affect reliability.
Maximum Ratings
(Above which useful life may be impaired. For user guidelines, not tested.)
DC Electrical Characteristics for Switching over Operating Range
(TA = –40°C to +85°C, VDD = 1.5V to 1.8V ±10%)
Parameters Description Test Conditions(1) Min Typ(2) Max Units
VIH Input HIGH Voltage Guaranteed HIGH level
0.65 x
VDD
V
VIL Input LOW Voltage Guaranteed LOW level –0.5 0.35 x
VDD
VIK Clamp Diode Voltage VDD = Max., IIN = –18mA –0.7 –1.2
IIH Input HIGH Current VDD = Max., VIN = VDD ±5
µA
IIL Input LOW Current VDD = Max., VIN = GND ±5
Dynamic Electrical Characteristics Over the Operating Range
(TA= -40º to +85ºC, VDD = 1.8V±10%, GND=0V)
Parameters Description Test Conditions Min. Typ.(2) Max. Units
XTALK Crosstalk See Fig. 1 for Measurement Setup, f= 3 GHz
f = 100 MHz
-23dB
-58dB dB
OIRR OFF Isolation See Fig. 2 for Measurement Setup, f= 3 GHz
f = 100 MHz
-23dB
-58dB
ILOSS Differential
Insertion Loss f= 3 GHz -2 dB
BW Bandwidth -3dB 4.1 GHz
Notes:
1. For Max. or Min. conditions, use appropriate value specied under Electrical Characteristics for the applicable device type.
2. Typical values are at VDD = 1.8V, TA = 25°C ambient and maximum loading.
Power Supply Characteristics
Parameters Description Test Conditions(1) Min. Typ.(2) Max. Units
IDD Quiescent Power Supply Current VDD = Max., VIN = GND or VDD 350 µA
Switching Characteristics
(TA= -40º to +85ºC, VDD = 1.8V±10%)
Parameters Description Min. Max. Units
tPZH, tPZL Line Enable Time - SEL to AN, BN, CN0.5 8.0 ns
tPHZ, tPLZ Line Disable Time - SEL to AN, BN, CN0.5 8.0
tb-b Bit-to-bit skew within the same differential pair 7 ps
tch-ch Channel-to-channel skew 35 ps
14-0036
4
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
Fig 1. Crosstalk Setup
Fig 2. Off-isolation setup
PI2PCIE2412
T R
S
HP11667A
50-ohm
50-ohm
50-ohm
HP4396B
100
-ohm
100
-ohm
PI2PCIE2412
T R
S
HP11667A
50-ohm
50-ohm
50-ohm
HP4396B
100
-ohm
14-0036
5
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
Fig 3. Crosstalk
Fig 4. Off Isolation
14-0036
6
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
Fig 5. Insertion Loss
14-0036
7
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
RT
4pF
CL
VDD
VIN VOUT
200-ohm
200-ohm
2 x VDD
Pulse
Generator D.U.T
Test Circuit for Electrical Characteristics(1-5)
Notes:
1. CL = Load capacitance: includes jig and probe capacitance.
2. RT = Termination resistance: should be equal to ZOUT of the Pulse Generator
3. Output 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
output 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
4. All input impulses are supplied by generators having the following characteristics: PRR ≤ MHz, ZO = 50Ω, tR ≤ 2.5ns, tF ≤ 2.5ns.
5. The outputs are measured one at a time with one transition per measurement.
Switch Positions
Test Switch
tPLZ, tPZL (output on B-side) 2 x VDD
tPHZ, tPZH (output on B-side) GND
Prop Delay Open
Switching Waveforms
Voltage Waveforms Enable and Disable Times
tPLZ
VDD/2 VDD/2
VDD
VOH
0V
VOL
VDD/2
VDD/2
tPHZ
tPZL
tPZH
Output 1
Output 2
VOL
VOH
SEL
VOL + 0.15V
VOH – 0.15V
14-0036
8
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
Test Circuit for Dynamic Electrical Characteristics
D.U.T.
Port2
Port1
Network Analyzer
Applications Information
Rail-to-Rail is a registered trademark of Nippon Motorola, Ltd
PCI Express Application Specific Measurements and Test Set-up
Figure 5: Test Setup
14-0036
9
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
Figure 6: 5 Gbps RX signal eye of the PCI-SIG compliance software test using PI2PCIE2412 + 16" test card
Figure 7. 5 Gbps RX signal eye of the PCI-SIG compliance software test with no switch + w/ 16" test card
14-0036
10
PI2PCIE2412
1.8V, PCI Express Gen2 Compliant, 4-Dierential
Channel, 2:1 Mux/DeMux Switch
www.pericom.com 03/26/2014
Ordering Information
Ordering Code Package Code Package Description
PI2PCIE2412ZHEX ZH 42-contact, Thin Fine Pitch Quad Flat No-Lead (TQFN)
Notes:
Thermal characteristics can be found on the company web site at www.pericom.com/packaging/
"E" denotes Pb-free and Green
Adding an "X" at the end of the ordering code denotes tape and reel packaging
Pericom Semiconductor Corporation • 1-800-435-2336 • www.pericom.com
Packaging Mechanical: 42-Contact TQFN (ZH)
DATE: 11/14/12
DESCRIPTION: 42-contact Thin Fine Pitch Quad Flat No-Lead (TQFN)
PACKAGE CODE: ZH42
DOCUMENT CONTROL #: PD-2035 REVISION:D
Notes:
1. All dimensions are in millimeters. Angles in degrees.
2. Coplanarity applies to the exposed pad as well as the terminals.
3. Refer JEDEC MO-220.
4. Recommended land pattern is for reference only.
5. Thermal pad soldering area
12-0529
14-0036