Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8457 Multi-Conductor - Audio, Control and Instrumentation Cable For more Information please call 1-800-Belden1 General Description: 22 AWG stranded (7x30) tinned copper conductors, conductors cabled, PVC insulation, PVC Jacket. Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 12 22 7x30 TC - Tinned Copper Total Number of Conductors: 12 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PVC - Polyvinyl Chloride 0.279 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.8128 Overall Cable Overall Cabling Color Code Chart: Color White Black Blue Brown Green Gray Orange Purple Red Pink Tan Yellow Overall Nominal Diameter: 6.909 mm Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +80C UL Temperature Rating: 80C (UL AWM Style 2576) Bulk Cable Weight: 69.945 Kg/Km Max. Recommended Pulling Tension: 489.302 N Min. Bend Radius/Minor Axis: 69.850 mm Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8457 Multi-Conductor - Audio, Control and Instrumentation Cable Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMG CEC/C(UL) Specification: CMG AWM Specification: UL Style 2576 (150 V 80C) CSA Specification: FT4 EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 FT4 Loading CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.55777 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 111.554 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 51.1836 Max. Operating Voltage - UL: Voltage Description 300 V RMS CMG 150 V RMS UL AWM Style 2576 Max. Recommended Current: Current 2.1 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 8457 060U1000 305 MT 22.226 KG CHROME Notes Item Desc 12 #22 PVC PVC 8457 060U500 152 MT 11.340 KG CHROME 12 #22 PVC PVC 8457 060100 30 MT 2.449 KG CHROME 8457 0601000 305 MT 23.133 KG CHROME C 12 #22 PVC PVC 8457 060500 152 MT 11.567 KG CHROME C 12 #22 PVC PVC 8457 0605000 1,524 MT 113.399 KG CHROME C 12 #22 PVC PVC 12 #22 PVC PVC Notes: C = CRATE REEL PUT-UP. Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8457 Multi-Conductor - Audio, Control and Instrumentation Cable Revision Number: 2 Revision Date: 08-31-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013