DC-DC CONVERTERS 81 A DC-DC Non-Isolated Converters 1
NXI150 Series
Single output
NEW Product
Filename: NXI150.PDF Rev (03): 20 Dec 2005
Meets VRM9.1 specification
Microprocessor voltage identification input
-5Bit VID input
-1.10 Vdc to 1.85 Vdc in 25 mV steps
Up to 50 A/µs load transient
Democratic current sharing, no need for
master/slave configuration
Remote sense for improved load regulation
Vertical plug-in to standard motherboard connector with
or without retention latch
Available RoHS compliant
The NXI150 non-isolated dc-dc converter is designed to meet the exceptionally fast
transient response requirements of today’s microprocessors and fast switching logic in
acompact size at a very affordable price. Advanced circuit techniques, component
selection and placement optimization, state-of-the-art thermal packaging, and Surface
Mount Technologies provide a high power density,highly reliable, and very precise
voltage regulation system for advanced microprocessors. Multi-phase power
conversion techniques allow the NXI converters to lead the industrywith regard to
conversion efficiency without adding unneccesarycomplexity.On-board active current
sharing circuit guarantees the current sharing specification is met during static and
dynamic load conditions. 2YEAR WARRANTY
All specifications aretypical at nominal input, full load at 25 °Cunless otherwise stated SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability 1.10-1.85 Vdc
Output setpoint accuracy Vout ±0.8%
Ripple and noise 20 MHz bandwidth 15 mV pk-pk
(See Notes 1 and 2)
Transient response See Note 3 50 mV
peak dev.settling time 25 µs
Short-circuit protection Continuous current limit,
foldback automatic
recovery
INPUT SPECIFICATIONS
Input voltage range 12 Vin nominal 11.0-12.6 Vdc
Input current Operation 16.2 A max.
No load 250 mA
Remote OFF 45 mA max.
UVLO turn ON voltage 10.45 V typ.
UVLO turn OFF Voltage 8.55 V typ.
Start-up time Nominal line 10 ms max.
OUTEN
Logic compatibility Ref. to -input
ON Open circuit >1.8 Vdc
OFF <0.8 Vdc
GENERAL CHARACTERISTICS
Efficiency 1.5 V output @ 65 A 85%
Switching frequency Fixed (See Note 4) 1 MHz
Standards 94V-0 Flammability rating
Weight 70 g (2.46 oz)
MTBF Telcordia SR-332 1,800,000 hours
Mating connector (See Note 5)
ENVIRONMENTAL SPECIFICATIONS
Maximum temperature Operating 5 ºC/10 min.
shock
Temperature shock Operating 10 ºC/hour
Non-operating 20 ºC/hour
Humidity Operating 85% RH
(Non-condensing) Storage 95% RH
Altitude Operating 10,000 feet max.
Storage 50,000 feet max.
Shock Operational and 50 G 11 ms,
non-operational half sine wave
Vibration Operational and 0.02 G2/Hz max.
(See Note 6) non-operational
Electrostatic discharge Operating ESD 15 kV
IEC61000-4-2 (See Note 7)
non-operating ESD 25 kV
Thermal performance Operating ambient 0 ºC to +60 ºC
(See Note 8) temperature
non-operating -40 ºC to +100 ºC
NXI150 Series
Single output
Filename: NXI150.PDF Rev (03): 20 Dec 2005
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
DC-DC CONVERTERS 81 A DC-DC Non-Isolated Converters 2
NEW Product
TABLE 1: PIN CONNECTIONS
PIN NO. FUNCTION PIN NO. FUNCTION
1 Vin+ 62 Vin-
2 Vin+ 61 Vin-
3 Vin+ 60 Vin-
4 Vin+ 59 Vin-
5 Reserved 58 VRM-pres
6 Key 57 VID4
7 VID3 56 VID2
8 VID1 55 VID0
9 Reserved 54 Ishare
10 PWRGD 53 OUTEN
11 Vo sen- 52 Vo sen+
12 Reserved 51 Reserved
13 Vo- 50 Vo+
14 Vo+ 49 Vo+
15 Vo- 48 Vo-
16 Vo+ 47 Vo+
17 Vo- 46 Vo-
18 Vo+ 45 Vo+
19 Vo- 44 Vo-
20 Vo+ 43 Vo+
21 Vo- 42 Vo-
22 Vo+ 41 Vo+
23 Vo- 40 Vo-
24 Vo+ 39 Vo+
25 Vo- 38 Vo-
26 Vo+ 37 Vo+
27 Vo- 36 Vo-
28 Vo+ 35 Vo+
29 Vo- 34 Vo-
30 Vo+ 33 Vo+
31 Vo- 32 Vo-
TABLE 2: VOLTAGE IDENTIFICATION (VID) CODES
VID4 VID3 VID2 VID1 VID0 VDAC
11 1 1 1Off
1 1 1 1 0 1.100
11 1 0 1 1.125
1 1 1 0 0 1.150
1 1 0 1 1 1.175
1 1 0 1 0 1.200
1 1 0 0 1 1.225
1 1 0 0 0 1.250
1 0 1 1 1 1.275
1 0 1 1 0 1.300
1 0 1 0 1 1.325
1 0 1 0 0 1.350
1 0 0 1 1 1.375
1 0 0 1 0 1.400
1 0 0 0 1 1.425
1 0 0 0 0 1.450
0 1 1 1 1 1.475
0 1 1 1 0 1.500
01101 1.525
0 1 1 0 0 1.550
0 1 0 1 1 1.575
0 1 0 1 0 1.600
01 0 0 1 1.625
0 1 0 0 0 1.650
0 0 1 1 1 1.675
001101.700
0 0 1 0 1 1.725
0010 0 1.750
000 1 1 1.775
0 0 0 1 0 1.800
0 0 0 0 1 1.825
000001.850
INPUT OUTPUT
OUTPUT OUTPUT
EFFICIENCY REGULATION MODEL
VOLTAGE VOLTAGE
OVP CURRENT CURRENT
(TYP.) LOAD NUMBER (9,10)
(MIN) (MAX.)
12 Vdc 1.10-1.85 Vdc 120% of 0 A 81 A 85% 0.95 mV/A NXI150-12P1V8CY
VID setting
NXI150 Series
Single output
0.250 (6.35) Max
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Place ±0.02
3 Place ±0.010
0.255 (6.48) Max
0.063 ±0.007 THICK
FR-4 2-Sided CKT BD
W/Gold Plated 30µ"
Connector Fingers
1
62 32
31
0.093 (2.36)
0.042 (1.07)
0.307 (7.80)
32
62
3.800 (96.52)
2.300 (58.42)
0.700 (17.78)
3.186 (80.92)
30 EQ Spaces @ 0.100 (2.54)
each Equals 3.000 (76.20)
TOL Non-Accum
1.243
(31.57)
C
L
0.936 (23.77)
Filename: NXI150.PDF Rev (03): 20 Dec 2005
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
DC-DC CONVERTERS 81 A DC-DC Non-Isolated Converters 3
NEW Product
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet arebelieved to be correct at time of publication. However,Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
Please consult your local application support for: 4Application Note 4Longform Datasheet www.artesyn.com
NNootteess
1Recommended output capacitance, 8 x 560 µF/4 V OSCON and 10 x
4.7 µF/6.3 V MLCC.
215 mV pk-pk ripple. Vin = 12 V, Vout = 1.5 V, Iout = 65 A.
3125 mV peak deviation when slewing load from no load to full load at 50
A/µs. Recommended capacitors (per Note 1) required across output.
4Each phase operates at a fixed 250 kHz. Effective fundamental output
frequency is 1 MHz / 4 phases each at 250 kHz interleaved.
5Recommended mating connector is AMP 1489162-1 or equivalent.
6From 5 Hz to 20 Hz, maintaining 0.02 G2/Hz from 20 Hz to 500 Hz, all
axes.
7When included in the users system ESD event shall cause no out-of-
regulation conditions.
NNootteess CCoonndd
8Please consult your local application support for: Longform Datasheet
and Application Note for the de-rating curves.
9The ‘Y’ suffix indicates that these parts are TSE RoHS 5/6 (non Pb-free)
compliant.
10 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
(11,12)
Figure 1: Mechanical Drawing