Absolute Maximum Ratings
Parameter Minimum Nominal Maximum Units Notes
Storage Temperature -55 - 125 °C
Supply Voltage - 3.3 Vdc (Vcc) -0.5 - 4.5 Vdc
Supply Voltage - 5.0 Vdc (Vcc) -0.5 - 7.0 Vdc
Supply Voltage - 12 Vdc (Vcc) -0.5 - 13.5 Vdc
Control Voltage (Vc) -0.5 - 7.0 Vdc
Operating Specifications
Parameter Minimum Nominal Maximum Units Notes
Center Frequency: (Fo) 5.0 - 40.0 MHz
Operating Temperature Range:
Temperature Code 5 0 - 70 °C
Temperature Code 6 -40 - 85 °C
Temperature Code 7 -20 - 70 °C
Temperature Code 8 -40 - 70 °C
Frequency Calibration: -0.1 - 0.1 ppm @ 25°C
Frequency Stability vs. Change in Temperature:
Stability Code 06 -3.0 - 3.0 ppb 1
Stability Code 10 -5.0 - 5.0 ppb 1
Stability Code 20 -10.0 - 10.0 ppb 1
Stability Code 50 -25.0 - 25.0 ppb 1
Frequency Stability vs Load -5.0 - 5.0 ppb ±5%
Frequency Stability vs Voltage -5.0 - 5.0 ppb ±5%
Aging: Daily:
5 MHz to 20 MHz -1.0 - 1.0 ppb/day 2
>20 MHz to 40 MHz -2.0 - 2.0 ppb/day 2
Aging: First Year:
5 MHz to 20 MHz -50 - 50 ppb
>20 MHz to 40 MHz -100 - 100 ppb
Lifetime Tolerance: (20 Years)
5 MHz to 20 MHz- -300 - 300 ppb 3
>20 MHz to 40 MHz -500 - 500 ppb 3
Supply Voltage: (Vcc) (Note: Power supply turn-on ramp time must be > 5 ms to 90% of Vcc.)
Voltage Code 03 3.13 3.30 3.47 Vdc
Voltage Code 05 4.75 5.00 5.25 Vdc
Voltage Code 12 11.40 12.00 12.60 Vdc
Power Consumption: Turn-On
0 to 70°C Models - - 3.00 W 4
-20 to 70°C Models - - 3.20 W 4
-20 to 75°C Models - - 3.30 W 4
-40 to 85°C Models - - 3.80 W 4
Power Consumption: Steady State @ 25°C
0 to 70°C Models - - 1.10 W 4
-20 to 70°C Models - - 1.10 W 4
-20 to 75°C Models - - 1.20 W 4
-40 to 85°C Models - - 1.50 W 4
Phase Jitter: (BW: 10 Hz to Fo/2)
Models with Fo: 5 MHz to 20 MHz - - 1.0 ps RMS
Models with Fo: >20 MHz to 40 MHz - - 2.0 ps RMS
Short Term Allan Deviation (1s) - 1.0E-11 - RMS
Start-Up Time: - - 500 ms
Warm Up Time @ 25°C: - - 5 minutes 5
Notes:
1. Frequency stability vs. change in temperature [±(Fmax-Fmin)/2.Fo].
2. At time of shipment after 48 hours of operation.
3. Inclusive of calibration, operating temperature, supply voltage change, load change and 20 years aging.
4. Measured with Vcc = Nominal, in calm air.
5. Measured @ 25°C, within 5 minutes, referenced one hour after turn-on.