Oscilloscopes Digital Multi Meter Digital Power Analyzers Handheld Digital Multi Meter Sellection Handhel Digital Multi Meter Models Function item Measurment Function TY710 TY720 TY520 TY530 73201 73202 73203 73204 73101 Ture RMS Ture RMS MEAN Sellect RMS RMS MEAN Sellect MEAN MEAN MEAN MEAN MEAN 0.5% 0.5% 0.3% 0.5% 0.7% Max. Measurrement Accuracy at DCV 0.02% Calibrator Optical Measuring Instruments Generators, Sources, Manometers etc. Wide bandwidth Data Logger Clamp-on Power Meter 1kHz -- -- 5 digits 3.5 Digits 3.5 Digits 3.5 Digits Max. Value 50000 6000 4300 4300 51 31 -- Bar Graph Dsiplay (Uints:Segment) LCD Back Light White LED LED -- Max.Measurement Voltage (AC/or DC) 50.000mV to 1000.0V 600.0mV to 1000V 600.0mV to 1000V 4.000V*3 to 600V 4.000V*3 to 600V 4.000V*3 to 600V Max.Measurement Currents (AC/or DC) 500.00A to 10.000A 500.00A to 10.000A 600.0A to 10.00A 600.0A to 10.00A 400.0A to 10.00A 400.0A to 10.00A 400.0A to 10.00A -- -- Max.Measurement Resistance 500.00 to 50.000M 500.00 to 50.000M 600.0 to 60.00M 600.0 to 60.00M 400.0 to 40.00M 400.0 to 40.00M 400.0 to 40.00M 400.0 to 40.00M 400.0 to 40.00M Max.Measurement Frequency 2.000Hz to 99.99kHz 2.000Hz to 99.99kHz 10.00Hz to 99.99kHz 10.00Hz to 99.99kHz -- -- -- -- -- Max.Measurement Capcitance 5.000nF to 50.00mF 5.000nF to 50.00mF 10.00nF to 1000F 10.00nF to 1000F -- 20.00nF to 200.0F 20.00nF to 200.0F -- -- Max.Measurement Temperature +1372C*1 +1372C*1 +600C*1 +600C*1 -- -- -- -- -- -- -- -- -- -- -- -- 4.000V*3 to 600V 4.000V*3 to 600V Low-Power -- -- -- -- -- -- -- -- AC+DC Measurement -- -- -- -- -- -- -- Max./Min./Ave. Value Memory -- -- -- -- -- -- Diode Test Continuity Check Relative/Percentage (%) calculation -- -- -- -- -- Decibel calculation -- -- -- -- -- -- Selection Auto range or Manual range -- Peak Hold -- -- -- -- -- -- -- -- Data Hold *2 Auto Hold Communication for PC Data Logging Memory * * 2 -- * 2 *2 *2 -- -- -- -- -- -- *2 -- -- -- -- 1000 -- 10000 -- 1600 -- -- -- -- -20 to 55C -- -20 to 55C -10 to 55C -10 to 55C 0 to 50C 0 to 50C 0 to 50C 0 to 50C 0 to 50C 2 Operating Temp. and Humidity Electric Safety 1000V CAT III CAT III Electric Safety 600V CAT IV CAT IV CAT II CAT III CAT III Electric Safety 300V -- -- CAT III -- -- CAT II -- *1 Temperature probe is necessary when measuring temperature. *2 The communications package (model: 92015) for DMM is necessary when connecting it with PC. *3 73101,732Series minimum range of DCvoltage is 400. 0 mVDC. Simple selection for replacing discontinued products Earth Tester, Other Products Existing model Meters Products Precision Measuring Instruments TY720 TY710 TY530 TY520 73201 73202 73203 73101 70 2 75 37 01 75 34 se rie s 75 33 se rie s 75 32 03 75 32 02 75 32 01 73 10 1 75 37 0 37 03 75 01 70 4 3.5 Digits 75 3 75 38 73 30 3 73 30 2 30 1 73 40 1 75 4 1 40 2 75 4 73 40 Insulation Tester Di sc on fo tin r r ue ep d la pr cin od 73 g uc 40 ts 2 4.5 Digits Thermometer 32 -- 50.000mV to 1000.0V Data Memory Digital Multimeter 100KHz Display Digits(Uint:Digit) Duty Ratio (%) Measuement Clamp-on Tester 0.09% 20KHz Oscilloscopes Digital Multi Meter 1000V ACV [MEAN] DCV+ACV 50mV 50mV/5V/ 50V/500V/1000V 5V/50V/500V 1000V DCA 500A/5000A/ 50mA/500mA 5A/10A ACA [MEAN] 500A/5000A/ 50mA/500mA 5A/10A Resistance Low-power Resistance Frequency Capacitance Continuity check Diode test Temperature -- -- Upper: DC,10 to 20Hz Lower: DC,20Hz to 1kHz 1.5+10 1+10 1.5+10 1+10 Upper: DC,1kHz to 10kHz Lower: DC,10kHz to 20kHz 1+10 2+10 -- -- Upper: DC,20kHz to 50kHz Lower: DC,50kHz to 100kHz -- -- -- -- 500A/5000A/ 50mA/500mA 5A 10A ACA [RMS] DCA+ACA 1.5+30 0.7+30 500A/5000A/ 50mA/500mA 5A/10A 500/5k/50k 500k 5M 50M 5k/50k/500k 5M 2.0Hz to 99.99kHz 5nF/50nF/500nF 5F/50F 500F 5mF/50mF 550 2.4V -200 to 1372C Upper: 20kHz to 50kHz Lower: 50kHz to 100kHz 15+40 15+40 2+70 5+200 -- -- 500Hz to 1kHz 5+30 2+30 1+30 3+30 Upper: DC,10 to 20Hz Lower: DC,20Hz to 1kHz 1.5+10 0.5+10 1.5+10 0.5+10 Upper: DC,1kHz to 10kHz Lower: DC,10kHz to 20kHz 0.5+10 1+10 -- -- Upper: DC,20kHz to 50kHz Lower: DC,50kHz to 100kHz 2+10 5+20 -- -- 0.2+5 10Hz to 20Hz 20Hz to 1kHz 1kHz to 5kHz 1.5+20 1+20 -- -- DC,10 to 20Hz -- DC,20Hz to 1kHz DC,1kHz to 5kHz 2+10 1.5+10 -- 0.6+10 0.6+5 10Hz to 20Hz 20Hz to 1kHz 1kHz to 5kHz 1+20 0.75+20 1+30 1.5+20 10Hz to 20Hz 1+20 20Hz to 1kHz 2+30 1kHz to 5kHz 2+20 1.5+20 2+30 3+20 DC,10 to 20Hz 2+20 DC,20Hz to 1kHz 4+30 DC,1kHz to 5kHz 1.5+10 1+10 1.5+10 2+10 1.5+10 0.1+2 Generators, Sources, Manometers etc. Optical Measuring Instruments 3+10 0.05+2 0.5+2 1+2 -- -- 0.2+3 1+3 0.02+1 Insulation Tester 50mV/5V/ 50V/500V Upper: 1kHz to 10kHz Lower: 10kHz to 20kHz 5+40 5.5+40 0.4+30 1+40 3+30 -- 20Hz to 500Hz 1.5+30 1+5 2+5 3+5 Buzzer sounds at 10050 or less 1+2 1+1.5C DMM of dedicated application software (Model: 92015 ) DMM's and you can easily manage the data in memory. Is also capable of real-time communications Features * Data saved in the internal memory PC transfer is possible (Save memories or Logging Memories) * DMM measurements show in real time monitor display is possible. * Large amounts of data not covered by the internal memory PC communication with data transfer is possible. At the same time Excel transferable is also. Maximum incoming data: 32767 * Measurement data to Excel direct deployment is possible. Automatically creates a chart sheet. 92015 product specification: Communication cable Communications cable: infrared communication adapter + communications cable (USB specifications) 2 m length Interface standards: USB specification conforms to the 1.1 Available models : TY710 , TY720 , TY530 71 Application software Operating environment of the personal computer OS: Windows XP / Vista / 7 CPU: Pentium 133 MHz or higher Memory: 64 MB Hard disk has free space or more storage: 10 MB Over, CD drive Excel: since the Excel2000 Software: CD, communication cable (including adapter), User's manual Earth Tester, Other Products 50mV Upper: 1kHz to 10kHz Lower: 10kHz to 20kHz -- -- 0.7+30 2+50 3+30 -- Thermometer ACV [RMS] Upper: 10 to 20Hz Lower: 20Hz to 1kHz -- -- TY720 Switching detection (RMS or MEAN) Accuracy 0.05+10 0.02+2 0.025+5 0.03+2 Upper: 20kHz to 50kHz Upper: 10 to 20Hz Lower: 50kHz to 100kHz Lower: 20Hz to 1kHz -- 2+80 -- 0.4+40 -- -- 1+30 0.4+30 -- -- 10 to 20Hz 4+80 Precision Measuring Instruments DCV TY710 RMS Range 50mV 500mV/2400mV 5V 50V/500V/1000V Meters Products Detection Item Calibrator Digital Multimeters Data Logger TY700 Series Clamp-on Power Meter General Specifications Additional Functions USB communication (optional adapter & software), data memory (TY720: 10,000 data, TY710: 1,000 data), max/min value memory, relative/percentage value computation, logarithm computation, data/auto hold, peak hold (TY720), overvoltage warning, backlight Power Supply Four AA (R6) dry cells Battery Life Approx. 120 hours Dimensions 90 (W) x 192 (H) x 49 (D) mm Weight Approximately 560 g (including batteries) Safety Standards 1000 V CAT. 3, 600 V CAT. 4 Digital Multimeter * Wide operating temperature range: -20 C to 55C Clamp-on Tester * Maximum Measurement Accuracy: 0.020% rdg + 2 dgt * Highly Reliable: Closed case calibration * Full Support of Data Management: Measured data stored in internal memory * Safe Design: Shutters prevent erroneous insertion of test leads into current measurementterminals (terminal shutters) * Shockproof elastomer casing Digital Power Analyzers A New De Facto Standard for Handheld DMM Oscilloscopes Digital Multi Meter Provides Safety Levels Demanded in Field Work Digital Power Analyzers TY500 Series Specifications Accuracy: (23C 5C, Less than 80% RH), (% rdg + dgt) Detection Generators, Sources, Manometers etc. Item Switching detection (RMS or MEAN) Range DCV Accuracy 0.09 + 2 1000V ACV Digital Multimeters Optical Measuring Instruments TY530 RMS 600mV/6V/ 60V/600V 3.5 digits (6,000-count, 31-segment bar graph display), RMS type Measurement Functions: Voltage, Current, Resistance, Continuity Check, Diode Test, Frequency, Capacitance, Temperature Features: Closed case calibration, Hi-impact overmold case, USB communication (optional adapter & software) (TY530 only), data memory (1,600 data for TY530 only) Safety Standards: 1000 V CAT. 3, 600 V CAT. 4 0.15 + 2 600mV/6V/60V/600V 1000V TY500 Series Calibrator TY520 50/60Hz 40 to 500Hz 0.5 + 5 1+ 5 600A/6000A/60mA DCA 1.5 + 5 -- 0.2 + 2 600mA/6A/10A 0.5 + 5 50/60Hz ACA 600A/6000A/60mA/ 600mA/6A/10A 40Hz to 1kHz 0.75 + 5 1.5 + 5 600/6k/60k/600k Resistance Frequency 0.4 + 1 6M 0.5 + 1 60M 1 + 2 (0 to 40M) 2 + 2 (40 to 60M) 10.0Hz to 99.99kHz 0.02 + 1 10nF Capacitance 2 + 10 100nF/1F/10F 2+5 100F/1000F 3+5 Continuity check 600 Data Logger 500Hz to 1kHz Diode test 2V Temperature -50 to 600C Buzzer sounds at 5030 or less 1+ 2 2 + 2C Clamp-on Power Meter General Specifications * External dimensions: 90 (W) x 192 (H) x 49 (D) mm * Weight: Approx. 570 g * Power Supply: Four AA (R6) dry cells Low-cost Handheld DMM 732 Series Specifications 73201 73202 Detection 732 Series Digital Multimeters 3.5 digits (4,300-count), Mean value type Measurement Functions: Voltage, Current, Resistance, Continuity Check, Diode Test, Capacitance Features: Auto hold, Auto power-off 73203 73204 Mean value Item Range DCV 400.0 mV/4.000 V/ 40.00 V/400.0 V/600 V ACV 4.000 V/40.00 V/ 400.0 V/600 V DCA 400.0 A/4000 A/ 40.00 mA/400.0 mA/ 10.00 A 1.0%+2 2.0%+2 - 400.0 A/4000 A/ ACA 40.00 mA/400.0 mA/ (40 to 500 Hz) 10.00 A 2.0%+20 2.0%+5 2.0%+20 2.0%+5 2.0%+20 - Resistance Accuracy 0.5%+1 0.75%+1 0.5%+1 0.3%+1 1.0%+5 0.5%+1 0.75%+5 0.75%+2 0.75%+1 2.0%+1 5.0%+2 400.0 /4.000 k/ 40.00 k/400.0 k/ 4.000 M/40.00 M General Specifications * External dimensions: 74 (W) x 155 (H) x 31 (D) mm * Weight: Approx. 240 g * Power Supply: Two AAA (LR03 or R03) dry cells Thermometer Earth Tester, Other Products Insulation Tester Clamp-on Tester Digital Multimeter Accuracy: (23C 5C, Less than 80% RH), (% rdg + dgt) Model Pocket DMM with Superb Portability 73101 Specifications Precision Measuring Instruments Accuracy: (23C 5C, Less than 80% RH), (% rdg + dgt) Item Range Accuracy Input Resistance DCV 400.0 mV 4.000 V 40.00/400.0/600 V 1.2%+2 0.7%+1 1.2%+1 >100 M 11 M 10 M ACV 4.000 V 40.00/400.0/600 V 2.0%+5 10 M 400.0 4.000 k/40.00 k/400.0 k 4.000 M 40.00 M 1.2%+2 2.0%+3 5.0%+3 Meters Products Resistance 73101 Continuity check Pocket Digital Multimeter Diode test 4300 count display Continuity Check and Diode Test Auto Hold Auto Power Off 400.0 2.00 V Genetal Specifications * External dimensions: 76 (W) x 117 (H) x 18 (D) mm * Weight: Approx. 110 g * Power Supply: Two LR-44 dry cells 72 - 1.5%+1 Open-circuit Voltage<3.4 V Testing Current<1.0 mA Oscilloscopes Digital Multi Meter Specifications 96095 Digital Power Analyzers Model 12mm Conductor Size Measurement range Accuracy (at 23C5C) Output voltage 50/60Hz AC10mV/A(AC 11300mVrms) DC 0 to 180A DC10mV/A (DC 01800mV) 40Hz to 1kHz 2.50.4mV 1.20.4mV 1.20.4mV Generators, Sources, Manometers etc. AC 0.1 to 130A -10 to 55C relative Humidity 85% or less (no condensation) Storage Temp&Humidity range -30 to 70C relative Humidity 85% or less (no condensation) DC3V(Size AAA alkaline Battery LR03 x 2pcs) Low battery warning 2.2V0.2V or less red LED flash 1.9V0.2V or less Power off Approx. 35Hours till a low battery indicator flashes *1 96095 Power source AD/DC Clamp-on Probe Continuous use * Light and compact, easy to carry and easy to clamp on crowded wirings. * Expands measuring span of currents and assure safety when measuring with any kind of DMM. Dimensions&Weight 127 (L) x 42 (W) x 22 (D) mm Cord length: Approx.1200mm Weight: Approx 140g Applicable standards EN61010-1CAT3Pollution degree2, Altitude 2000m or less for indoor use EN61326-1ClassB,EN61326-2-032 Accessories Optical Measuring Instruments General specifications Operating Temp&Humidity range Soft case(94030),Battery,User's Manual Calibrator *1 From low battery warning to power off is about 5hours Standerd Accessories Applicable DMM Models TY500 TY520 TY530 Test leads 98073 RD031 1000V CAT# 600V CAT $ Red/Black(1set) L-plug,Red/Black(1set) Fuse 99015 440mA/1000V 99016 F02 10A/1000V 15A/250V 500mA/250V 02 03 04 Accessorise Applicable DMM Models Specification TY710 TY720 92015 Communication Adapter for USB+cable+Application Software Test leads with Alligator Clip 99014 1000V CAT# 600V CAT$ Red/Black(1set) Red/Black(1set) Alligator Clips Rubber Case B9646HF 93007 Carrying Case Currents Clamp-on probe TY530 01 02 03 04 Hard case B9646GB 90050 Hard case -50 to 150C for liquld 90051 -50 to 600C for liquld 90055 90056 -20 to 250C for surface -20 to 500C for surface 93029 Temperature Probe (Thermocouple type K) (Banana plag output) TY520 732 Model 96001 96095 1 For 400AAC Output:AC10mV/A* For 130AAC/180ADC Output: AC10mV/A or DC10mV/A*2 *1 Please use it with the ACV range. It is necessary to read the indicated value in a different way as TY710 and the TY720,732 series. The example: In AC1V display = 100A TY520 and TY530, it is possible to scale it. (Even 60A or less display is possible in case of 96001. ) *2 Please use it with ACV or DCV range. It is necessary to read the indicated value in a different way as TY710 and the TY720,732 series. The example: In AC1V display = 100A TY520 and TY530, it is possible to scale it. (Even 60A or less display is possible in case of 96095. ) DMM Accessories 323 90050 1200 200 273 1200 10 50 110 50 10 50 10 50 10 1.6 14 22 150 92015 50 14 22 3.2 90051 93029 50 110 98073 178 90055 15 26 30 1200 110 50 6 6.0 14 14 177.5 90056 15 25.5 30 1200 110 96001 RD031 73 14 6.0 5.5 13.5 96095 Digital Multimeter TY500 Name Communication Package for Digital Multimeters Clamp-on Tester TY700 Insulation Tester F05 732 01 Data Logger TY720 Clamp-on Power Meter TY710 Earth Tester, Other Products Specification Precision Measuring Instruments Model Meters Products Name Thermometer TY700