EAO – Your Expert Partner for
Human Machine Interfaces
EAO Product Information
Series 61
61
Switches and Indicators
61
Contents
2
01.2009
Description......................................................................................................3
Product Assembly ..........................................................................................4
Mounting instruction......................................................................................9
Devices raised mounting .............................................................................11
Devices flush mounting ...............................................................................19
Accessories...................................................................................................25
Technical Data...............................................................................................43
Typical Applications.....................................................................................47
Application guidelines..................................................................................49
Marking..........................................................................................................50
Drawings........................................................................................................53
Index...............................................................................................................70
3
01.2009
61
Description
General notes
The indicators, illuminated pushbuttons, selector-, keylock switches or
emergency-stop switches with spray-water protection at the front
(IP 65) are modular and consist of an actuator and switching element.
In addition to the standard switching elements (gold-plated silver
contact or silver contact with universal soldering terminals), forced-
opening, slow-make switching elements with gold or silver contacts with
soldering terminals are available. EAO can also offer screw terminals
on its slow make elements. Switching elements with soldering terminals
can also be fitted with flat receptacle 2.8 x 0.5 mm.
The front dimensions of the units in this series are 24 x 24 mm, 24 mm
dia., 18 x 24 mm, 18 x 18 mm or 18 mm dia. For flush mounting the
dimensions 25 mm dia., 24 x 30 mm or 24 x 24 mm can be supplied.
Mounting
All switch actuators are mounted from the front by pushing them through
the mounting hole in the front panel. They are then fixed from the back
with a fixing nut and the mounting tool Typ-Nr. 01-907. Max. tightening
torque 50 Ncm.
The preassembled switching element with the connecting wires in a
single plane can be clipped on afterwards. A range of assembly and
service tools are available.
PCB mounting adaptors are available for universal solder terminal
switching elements.
All raised profile actuators are provided with an anti-twist device.
Lenses
The flat or concave lenses are available in various colours and a
transparent or translucent version. The lens surface is non-reflecting
(mat). Round lenses for devices 24 mm dia. or 25 mm dia. can also be
supplied in aluminium.
Anodized aluminium parts can have visible variations due production-
technical reasons.
Marking
For further information about engraving, hot stamping and film inserts
see part Marking.
Illumination
T1 3/4 midget groove LED's in red, blue, green, yellow and white or
filament lamps give superb illumination and can be supplied in 6, 12, 24,
or 48 V.
Luminosity and wave length scattering caused by the technology used
in the LED manufacturing processes may lead to visual differences in
our products.
Position indication
The status of a maintained action switch can be determinded by the
position of the lens.
Keylock switch
Standard lock (Index D). Standard lock number is 311. If the lock
number is not specified, we will supply standard number 311.
An additional 134 special locks (Index X) are available on request.
Master keys for lock numbers 311 ... 445 may be ordered by quoting
Typ-Nr. 31-989.300. Two keys are supplied with each keylock switch.
Spare keys (Index D) for standard locks may be ordered by quot ing
Typ-Nr. 31-989.xxx (please state the lock number).
Emergency-stop pushbutton, foolproof with key to release
KABA safety lock. Standard lock number is 1001. Other lock numbers
are available on request. Spare keys for KABA safety lock may be
ordered under Typ-Nr. 14-987.xxx (please state the lock number).
Specimen order
0
We reserve the right to modify technical data
All dimensions in mm
Product Information Indicator :
- Indicator complete, flush mounting, 24 x 24 mm 61-0000.02
Essential accessories :
- Lens plastic colourless transparent flush,
24 x 24 mm 61-9671.7
- Single-LED T1 3/4 MG, 24 VAC/DC, white
diffuse 10-2J12.1069
- Front bezel set for Indicator, flush mounting,
plastic black, 24 x 24 mm 61-9930.0
61
Product Assembly
4
01.2009
Pushbutton illuminative, raised mounting
01 Lens
2LED
3 Actuator housing
4 Sealing
5 Front plate
6 Fixing nut
7 Switching element
Emergency-stop pushbutton
01 Emergency-stop pushbutton actuator
2 Sealing
3 Front plate
4 Fixing nut
5 Switching element
1
2
3
4
5
6
7
1
2
3
4
5
61
Product Assembly
5
01.2009
Mushroom-head pushbutton, raised mounting
01 Mushroom-head cap
2 Front ring
3 Actuator housing
4 Sealing
5 Front plate
6 Fixing nut
7 Switching element
Keylock switch, raised mounting
01Key
2 Keylock front bezel
3 Keylock switch actuator
4 Sealing
5 Front plate
6 Fixing nut
7 Switching element
1
2
3
4
5
6
7
1
2
3
4
5
6
7
61
Product Assembly
6
01.2009
Selector switch illuminative, raised mounting
01 Lever
2LED
3 Selector switch actuator
4 Sealing
5 Front plate
6 Fixing nut
7 Switching element
Pushbutton illuminative, flush mounting
01 Lens
2LED
3 Actuator housing
4 Sealing
5 Front bezel
6 Sealing
7 Front panel
8 Fixing bracket
9 Fixing nut
10 Switching element
1
3
2
4
5
6
7
1
2
3
4
5
7
6
8
9
10
61
Product Assembly
7
01.2009
Keylock switch, flush mounting
01Key
2 Keylock front bezel
3 Keylock switch actuator
4 Sealing
5 Front bezel
6 Sealing
7 Front plate
8 Fixing bracket
9 Fixing nut
10 Switching element
1
2
3
7
4
5
6
8
9
10
61
Product Assembly
8
01.2009
Selector switch illuminative, flush mounting
01 Lever
2LED
3 Selector switch actuator
4 Sealing
5 Front bezel
6 Sealing
7 Front plate
8 Anti-twist ring
9 Thrust piece
10 Fixing nut
11 Switching element
1
3
2
4
5
9
10
11
7
6
8
61
Mounting instruction
9
01.2009
Lens remover, Mounting tool, Dismantling tool with Lamp- and LED remover are part of the Tool set K61-999.100
0
>
Tool set
Lens remover
61-9730.0
Mounting tool
01-907
Dismantling tool
61-9711.0
Lens remover
02-905
1 Snap-action switching element with soldering terminal
2 Slow-make switching element with soldering terminal
3 Slow-make switching element with screw terminal
Mounting tool
01-907
Dismantling tool
61-9711.0
1
2
3
1
2
3
raised mounting flush mounting
61
Mounting instruction
10
01.2009
Conversion is not reversible !
0
0
Conversion from momentary to maintained action
1 Momentary action 2 Maintained action
push carefully the metallic part with a screwdriver till the end of its travel.
61
Devices raised mounting
11
01.2009
Essential Accessories:
d Front ring, raised mounting page 31
d Lens plastic, raised mounting page 25
d Single-LED page 39
Continuation see next page
Front ring required only for actuator Ø 24 mm
Terminals: S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm)
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Essential Accessories:
d Front ring, raised mounting page 31
d Lamp element page 33
d Lens plastic, raised mounting page 25
d Single-LED page 39
Continuation see next page
Front ring required only for actuator Ø 24 mm
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Indicator complete
Front protection
Terminals
b 24 x 24 mm
Typ-Nr.
b 18 x 18 mm
Typ-Nr.
a 18 x 24 mm
Typ-Nr. Ø 24 mm
Typ-Nr. Ø 18 mm
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Indicator complete
Actuator housing black IP 65 S1 61-0050.02 61-0020.02 61-0030.02 61-0040.02 61-0010.02 3340.005
Indicator actuator
Front protection
b 24 x 24 mm
Typ-Nr.
b 18 x 18 mm
Typ-Nr.
a 18 x 24 mm
Typ-Nr. Ø 24 mm
Typ-Nr. Ø 18 mm
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Indicator actuator
Actuator housing black IP 65 61-0059.0 61-0029.0 61-0039.0 61-0049.0 61-0019.0 3 14 4 0.005
61
Devices raised mounting
12
01.2009
Essential Accessories:
d Front ring, raised mounting page 31
d Lens plastic, raised mounting page 25
d Single-LED page 39
d Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
Continuation see next page
Front ring required only for actuator Ø 24 mm
M-MA convertible from Momentary to Maintained action
Switching action: MA = Maintained action, M = Momentary action, M-MA = Momentary action-Maintained action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Illuminated pushbutton actuator
Front protection
Switching action
b 24 x 24 mm
Typ-Nr.
b 18 x 18 mm
Typ-Nr.
a 18 x 24 mm
Typ-Nr. Ø 24 mm
Typ-Nr. Ø 18 mm
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Illuminated pushbutton ac-
tuator
Actuator housing black
IP 65 MA 61-1250.0 61-1220.0 61-1230.0 61-1240.0 61-1210.0 3 16 6 0.005
M61-1150.0 61-1120.0 61-1130.0 61-1140.0 61-1110.0 3 16 13 0.005
M-MA 61-1350.0 61-1320.0 61-1330.0 61-1310.0 3 16 13 0.005
61
Devices raised mounting
13
01.2009
Application as per DIN EN ISO 13850 and EN 60204-1
Essential Accessories:
d Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36
Continuation see next page
Other lock numbers on request
Switching action: MA = Maintained action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Emergency-stop pushbutton actuator, foolproof EN IEC 60947-5-5
Front protection
Switching action
Mushroom had cap Marking Ø 27 mm
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Emergency-stop pushbutton actuator, foolproof
EN IEC 60947-5-5
Position indication ring black
Key to unlock clockwise
Standard lock 1001
IP 65 MA Plastic red Stop 61-5441.4/K 1 19 5 0.033
Position indication ring black
Twist to unlock clockwise IP 65 MA Plastic red Arrows 61-3440.4/1 1 19 5 0.020
Stop + Arrows 61-3440.4/2 1 19 5 0.020
Position indication ring black
Twist to unlock clockwise
with adaptor for mosaic
IP 65 MA Plastic red Arrows 61-3440.4/1S 1 19 5 0.021
Position indication ring black
Twist to unlock clockwise
with metal Fixing nut
IP 65 MA Plastic red Arrows 61-3440.4/D 1 19 5 0.020
Position indication ring green
Twist to unlock clockwise IP 65 MA Plastic red Arrows 61-3440.4/5 1 19 5 0.020
61
Devices raised mounting
14
01.2009
Essential Accessories:
d Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36
d Switching element for Stop pushbutton, foolproof page 37
Continuation see next page
Other lock numbers on request
Switching action: MA = Maintained action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Essential Accessories:
d Front ring, raised mounting page 31
d Mushroom-head cap page 28
d Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
Continuation see next page
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Stop pushbutton actuator, foolproof
Front protection
Switching action
Mushroom had cap Marking Ø 27 mm
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Stop pushbutton actuator, foolproof
Position indication ring black
Key to unlock clockwise
Standard lock 1001
IP 65 MA Plastic black without 61-5441.0/KA 1 19 5 0.033
Position indication ring black
Twist to unlock clockwise IP 65 MA Plastic grey Arrows 61-3440.4/8 1 19 5 0.020
Mushroom-head pushbutton actuator
Front protection
Switching action
Ø 32 mm
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Mushroom-head pushbutton actuator
Actuator housing black IP 65 MA 61-1240.0 1 15 2 0.005
M61-1140.0 1 15 3 0.005
61
Devices raised mounting
15
01.2009
if mounted with anti-twist device, the lug is on the left side
Actuators usable for front dimensions: b 24 x 24 mm | b 18 x 18 mm | a 18 x 24 mm | 24 mm dia. | 18 mm dia.
Essential Accessories:
d Anti-twist ring page 41
d Keylock front bezel, raised mounting page 28
d Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
Continuation see next page
Other lock numbers on request
Anti-twist ring (not needed by using anti-twist device)
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Keylock switch actua tor 2 positions
0
Front protection
Switching action
Key remove
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Keylock switch actuator 2 positions
Position A: Basic position
Position C: Maintained action
Standard lock 311
IP 65 MA A 61-2201.0/D 317170.065
C61-2203.0/D 317170.065
C + A 61-2205.0/D 317170.065
Position A: Basic position
Position C: Momentary action
Standard lock 311
IP 65 M A 61-2101.0/D 317160.065
61
Devices raised mounting
16
01.2009
if mounted with anti-twist device, the lug is on the left side
Actuators usable for front dimensions: b 24 x 24 mm | b 18 x 18 mm | a 18 x 24 mm | 24 mm dia. | 18 mm dia.
Essential Accessories:
d Anti-twist ring page 41
d Keylock front bezel, raised mounting page 28
d Switching element for Keylock- and Selector switch 3 positions page 36
Continuation see next page
Anti-twist ring (not needed by using anti-twist device)
Other lock numbers on request
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Keylock switch actuator 3 positions
0
Front protection
Switching action
Key remove
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Keylock switch actuator 3 positions
Pos. C: Maintained action
Pos. A: Basic posi tion
Pos. B: Maintained action
Standard lock 311
IP 65 MA-0-MA A 61-2601.0/D 3 17 19 0.065
A + B 61-2604.0/D 3 17 19 0.065
B61-2602.0/D 3 17 19 0.065
C61-2603.0/D 3 17 19 0.065
C + A 61-2605.0/D 3 17 19 0.065
C + A + B 61-2607.0/D 3 17 19 0.065
C + B 61-2606.0/D 3 17 19 0.065
Pos. C: Maintained action
Pos. A: Basic posi tion
Pos. B: Momentary action
Standard lock 311
IP 65 MA-0-M A 61-2701.0/D 3 17 18 0.065
C61-2703.0/D 3 17 18 0.065
C + A 61-2705.0/D 3 17 18 0.065
Pos. C: Momentary action
Pos. A: Basic posi tion
Pos. B: Maintained action
Standard lock 311
IP 65 M-0-MA A + B 61-2804.0/D 3 17 15 0.065
B61-2802.0/D 3 17 15 0.065
Pos. C: Momentary action
Pos. A: Basic posi tion
Pos. B: Maintained action
Standard lock 311
IP 65 M-0-MA A 61-2801.0/D 3 17 15 0.065
Pos. C: Momentary action
Pos. A: Basic posi tion
Pos. B: Momentary action
Standard lock 311
IP 65 M-0-M A 61-2501.0/D 3 17 14 0.065
61
Devices raised mounting
17
01.2009
illuminative
if mounted with anti-twist device, the lug is on the left side
Actuators usable for front dimensions: b 26 x 26 mm | b 24 x 24 mm | 18 mm dia.
Essential Accessories:
d Anti-twist ring page 41
d Lever, raised mounting page 29
d Single-LED page 39
d Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
Continuation see next page
Anti-twist ring (not needed by using anti-twist device)
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Selector switch actuator 2 positions
0
Front protection
Switching action
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Selector switch actuator 2 positions
Position C: Maintained action
Position A: Basic position
IP 65 MA 61-4210.0 3 18 8 0.006
Position C: Momentary action
Position A: Basic position IP 65 M 61-4110.0 3 18 7 0.006
61
Devices raised mounting
18
01.2009
illuminative
if mounted with anti-twist device, the lug is on the left side
Actuators usable for front dimensions: b 26 x 26 mm | b 24 x 24 mm | 18 mm dia.
Essential Accessories:
d Anti-twist ring page 41
d Lever, raised mounting page 29
d Single-LED page 39
d Switching element for Keylock- and Selector switch 3 positions page 36
Continuation see next page
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Selector swit ch actuator 3 positions
0
Front protection
Switching action
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Selector switch actuator 3 positions
Position C: Maintained action
Position A: Basic position
Position B: Maintained action
IP 65 MA-0-MA 61-4610.0 3 18 12 0.006
Position C: Maintained action
Position A: Basic position
Position B: Momentary action
IP 65 MA-0-M 61-4710.0 3 18 11 0.006
Position C: Momentary action
Position A: Basic position
Position B: Maintained action
IP 65 M-0-MA 61-4810.0 3 18 10 0.006
Position C: Momentary action
Position A: Basic position
Position B: Momentary action
IP 65 M-0-M 61-4510.0 3 18 9 0.006
61
Devices flush mounting
19
01.2009
Actuators usable for front dimensions: b 24 x 24 mm | a 24 x 30 mm | 25 mm dia.
Essential Accessories:
d Front bezel set for Indicators and Illuminated pushbutton, flush mounting page 30
d Lens plastic, flush mounting page 25
d Single-LED page 39
Continuation see next page
Terminals: S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm)
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Actuators usable for front dimensions: b 24 x 24 mm | a 24 x 30 mm | 25 mm dia.
Essential Accessories:
d Front bezel set for Indicators and Illuminated pushbutton, flush mounting page 30
d Lamp element page 33
d Lens plastic, flush mounting page 25
d Single-LED page 39
Continuation see next page
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Indicator complete, flush mounting
Front protection
Terminals
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Indicator complete, flush mounting IP 65 S1 61-0000.02 4440.006
Indicator actuator, flush mounting
Front protection
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Indicator actuator, flush mounting IP 65 61-0009.0 4 21 4 0.005
61
Devices flush mounting
20
01.2009
Actuators usable for front dimensions: b 24 x 24 mm | a 24 x 30 mm | 25 mm dia.
Essential Accessories:
d Front bezel set for Indicators and Illuminated pushbutton, flush mounting page 30
d Lens plastic, flush mounting page 25
d Single-LED page 39
d Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
Continuation see next page
M-MA convertible from Momentary to Maintained action
Switching action: MA = Maintained action, M = Momentary action, M-MA = Momentary action-Maintained action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Essential Accessories:
d Front bezel set for Mushroom-head pushbutton, flush mounting page 30
d Mushroom-head cap page 28
d Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
Continuation see next page
M-MA convertible from Momentary to Maintained action
Switching action: MA = Maintained action, M = Momentary action, M-MA = Momentary action-Maintained action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Illuminated pushbutton actuator, flush mounting
Front protection
Switching action
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Illuminated pushbutton actuator, flush mounting IP 65 MA 61-1200.0 4 20 2 0.005
M61-1100.0 4 20 3 0.005
M-MA 61-1300.0 4 20 3 0.005
Mushroom-head pushbutton actuator, flush mounting
Front protection
Switching action
Ø 32
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Mushroom-head pushbutton actuator, flush mounting IP 65 MA 61-1200.0 2 24 2 0.005
M61-1100.0 2 24 3 0.005
M-MA 61-1300.0 2 24 3 0.005
61
Devices flush mounting
21
01.2009
Actuators usable for front dimensions: b 24 x 24 mm | a 24 x 30 mm | 25 mm dia.
Essential Accessories:
d Front bezel set for Keylock switch, flush mounting page 31
d Keylock front bezel, flush mounting page 28
d Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
Continuation see next page
Other lock numbers on request
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Keylock switch actuator 2 positions, flush moun ting
0
Front protection
Switching action
Key remove
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Keylock switch actuator 2 positions, flush mounting
Position A: Basic position
Position C: Maintained action
Standard lock 311
IP 65 MA A 61-2201.0/D 422170.065
C61-2203.0/D 422170.065
C + A 61-2205.0/D 422170.065
Position A: Basic position
Position C: Momentary action
Standard lock 311
IP 65 M A 61-2101.0/D 422160.065
61
Devices flush mounting
22
01.2009
Actuators usable for front dimensions: b 24 x 24 mm | a 24 x 30 mm | 25 mm dia.
Essential Accessories:
d Front bezel set for Keylock switch, flush mounting page 31
d Keylock front bezel, flush mounting page 28
d Switching element for Keylock- and Selector switch 3 positions page 36
Continuation see next page
Other lock numbers on request
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Keylock switch actuator 3 positions, flush mounting
0
Front protection
Switching action
Key remove
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Keylock switch actuator 3 positions, flush mounting
Pos. C: Maintained action
Pos. A: Basic posi tion
Pos. B: Maintained action
Standard lock 311
IP 65 MA-0-MA A 61-2601.0/D 4 22 19 0.065
A + B 61-2604.0/D 4 22 19 0.065
B61-2602.0/D 4 22 19 0.065
C61-2603.0/D 4 22 19 0.065
C + A 61-2605.0/D 4 22 19 0.065
C + A + B 61-2607.0/D 4 22 19 0.065
C + B 61-2606.0/D 4 22 19 0.065
Pos. C: Maintained action
Pos. A: Basic posi tion
Pos. B: Momentary action
Standard lock 311
IP 65 MA-0-M A 61-2701.0/D 4 22 18 0.065
C61-2703.0/D 4 22 18 0.065
C + A 61-2705.0/D 4 22 18 0.065
Pos. C: Momentary action
Pos. A: Basic posi tion
Pos. B: Maintained action
Standard lock 311
IP 65 M-0-MA A + B 61-2804.0/D 4 22 15 0.065
B61-2802.0/D 4 22 15 0.065
Pos. C: Momentary action
Pos. A: Basic posi tion
Pos. B: Maintained action
Standard lock 311
IP 65 M-0-MA A 61-2801.0/D 4 22 15 0.065
Pos. C: Momentary action
Pos. A: Basic posi tion
Pos. B: Momentary action
Standard lock 311
IP 65 M-0-M A 61-2501.0/D 4 22 14 0.065
61
Devices flush mounting
23
01.2009
illuminative
Actuators usable for front dimensions: b 24 x 24 mm | 25 mm dia.
Essential Accessories:
d Front bezel set for Selector switch, flush mounting page 31
d Lever, flush mounting page 29
d Single-LED page 39
d Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
Continuation see next page
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Selector switch actuator 2 positions, flush mountin g
0
Front protection
Switching action
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Selector switch actuator 2 positions, flush mounting
Position C: Maintained action
Position A: Basic position
IP 65 MA 61-4210.0 4 23 8 0.006
Position C: Momentary action
Position A: Basic position IP 65 M 61-4110.0 4 23 7 0.006
61
Devices flush mounting
24
01.2009
illuminative
Actuators usable for front dimensions: b 24 x 24 mm | 25 mm dia.
Essential Accessories:
d Front bezel set for Selector switch, flush mounting page 31
d Lever, flush mounting page 29
d Single-LED page 39
d Switching element for Keylock- and Selector switch 3 positions page 36
Continuation see next page
Switching action: MA = Maintained action, M = Momentary action
Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Continuation see next page
Cable length 300 mm
Terminals: FR = Flat ribbon cable
Component layout from page 53, Mounting dimensions from page 58, Technical drawing from page 59, Circuit drawing from page 66
Selector switch actuator 3 positions, flush mounting
0
Front protection
Switching action
Typ-Nr.
Mounting dimensions
Technical drawing
Circuit drawing
e
Selector switch actuator 3 positions, flush mounting
Position C: Maintained action
Position A: Basic position
Position B: Maintained action
IP 65 MA-0-MA 61-4610.0 4 23 12 0.006
Position C: Maintained action
Position A: Basic position
Position B: Momentary action
IP 65 MA-0-M 61-4710.0 4 23 11 0.006
Position C: Momentary action
Position A: Basic position
Position B: Maintained action
IP 65 M-0-MA 61-4810.0 4 23 10 0.006
Position C: Momentary action
Position A: Basic position
Position B: Momentary action
IP 65 M-0-M 61-4510.0 4 23 9 0.006
Potentiometer, flush mounting
Front protection
Front bezel
Terminals
b 24 x 24 mm
Typ-Nr. Ø 25 mm
Typ-Nr.
Component layout
Mounting dimensions
Technical drawing
Circuit drawing
e
Potentiometer, flu sh mounting
10 k Ω (linear), 1 W, mechanical travel 300 ° IP 65 Plastic black FR 61-4970.13 40 4 9 1 0.023
61-4970.10 40 4 9 1 0.016
25
01.2009
61
Accessories
mat
Continuation see next page
mat
Continuation see next page
Front
Lens plastic, raised mounting
Lens
b 24 x 24 mm
Typ-Nr.
b 18 x 18 mm
Typ-Nr.
a 18 x 24 mm
Typ-Nr. Ø 24 mm
Typ-Nr. Ø 18 mm
Typ-Nr. e
Lens plastic,
raised
mounting
flush,
illuminative
blue transparent 61-9351.6 61-9321.6 61-9331.6 61-9642.6 61-9311.6 0.002
colourless transparent 61-9351.7 61-9321.7 61-9331.7 61-9642.7 61-9311.7 0.002
green transparent 61-9351.5 61-9321.5 61-9331.5 61-9642.5 61-9311.5 0.002
orange transparent 61-9351.3 61-9321.3 61-9331.3 61-9642.3 61-9311.3 0.002
red transparent 61-9351.2 61-9321.2 61-9331.2 61-9642.2 61-9311.2 0.002
smoked transparent 61-9351.1 61-9321.1 61-9331.1 61-9642.1 61-9311.1 0.002
yellow transparent 61-9351.4 61-9321.4 61-9331.4 61-9642.4 61-9311.4 0.002
flush,
non-illuminative black opaque 61-9251.0 61-9221.0 61-9231.0 61-9211.0 0.002
grey opaque 61-9251.8 61-9221.8 61-9231.8 61-9211.8 0.002
white translucent 61-9251.9 61-9221.9 61-9231.9 61-9211.9 0.002
concave,
illuminative blue transparent 61-9326.6 61-9336.6 0.002
colourless transparent 61-9326.7 61-9336.7 0.002
green transparent 61-9326.5 61-9336.5 0.002
orange transparent 61-9326.3 61-9336.3 0.002
red transparent 61-9326.2 61-9336.2 0.002
yellow transparent 61-9326.4 61-9336.4 0.002
concave,
non-illuminative black opaque 61-9226.0 61-9236.0 0.002
grey opaque 61-9226.8 61-9236.8 0.002
white translucent 61-9226.9 61-9236.9 0.002
Lens plastic, flush mounting
Lens
b 24 x 24 mm
Typ-Nr.
a 24 x 30 mm
Typ-Nr. Ø 25 mm
Typ-Nr. e
Lens plastic, flush mounting
illuminative blue transparent flush 61-9671.6 61-9681.6 61-9642.6 0.002
colourless transparent flush 61-9671.7 61-9681.7 61-9642.7 0.002
green transparent flush 61-9671.5 61-9681.5 61-9642.5 0.002
orange transparent flush 61-9671.3 61-9681.3 61-9642.3 0.002
red transparent flush 61-9671.2 61-9681.2 61-9642.2 0.002
smoked transparent flush 61-9671.1 61-9681.1 61-9642.1 0.002
yellow transparent flush 61-9671.4 61-9681.4 61-9642.4 0.002
non-illuminative black opaque flush 61-9771.0 61-9781.0 0.002
grey opaque flush 61-9771.8 61-9781.8 0.002
white translucent flush 61-9771.9 61-9781.9 0.002
26
01.2009
61
Accessories
Continuation see next page
The silvery coat is being applied on the lens (screen print) with an additional protective lacquer.
Continuation see next page
The silvery coat is being applied on the lens (screen print) with an additional protective lacquer.
can be hot stamped
Continuation see next page
Lens plastic with symbol, raised mounting
Symbol Lens Ø 24 mm
Typ-Nr. e
Lens plastic with symbol, raised mounting
flush - level, illuminative Ring blue transparent 61-9643.601 0.002
colourless transparent 61-9643.701 0.002
green transparent 61-9643.501 0.002
orange transparent 61-9643.301 0.002
red transparent 61-9643.201 0.002
yellow transparent 61-9643.401 0.002
ON/OFF blue transparent 61-9643.602 0.002
colourless transparent 61-9643.702 0.002
green transparent 61-9643.502 0.002
red transparent 61-9643.202 0.002
Stand by blue transparent 61-9643.603 0.002
colourless transparent 61-9643.703 0.002
green transparent 61-9643.503 0.002
red transparent 61-9643.203 0.002
Lens plastic with symbol, flush mounting
Symbol Lens Ø 25 mm
Typ-Nr. e
Lens plastic with symbol, flush mounting
flush - level, illuminative Ring blue transparent 61-9643.601 0.002
colourless transparent 61-9643.701 0.002
green transparent 61-9643.501 0.002
orange transparent 61-9643.301 0.002
red transparent 61-9643.201 0.002
yellow transparent 61-9643.401 0.002
ON/OFF blue transparent 61-9643.602 0.002
colourless transparent 61-9643.702 0.002
green transparent 61-9643.502 0.002
red transparent 61-9643.202 0.002
Stand by blue transparent 61-9643.603 0.002
colourless transparent 61-9643.703 0.002
green transparent 61-9643.503 0.002
red transparent 61-9643.203 0.002
Marking plate for lens plastic
Marking plate Typ-Nr. e
Marking plate for lens plastic
only applicable with Lens round Typ-Nr. 61-9642.X Plastic colourless transparent 61-9707.7 0.001
27
01.2009
61
Accessories
mat
Continuation see next page
mat
Continuation see next page
mat
Continuation see next page
Lens metal with window, raised mounting
Lens Ø 24 mm
Typ-Nr. e
Lens metal with window, raised mounting Aluminium black flush 61-9841.0A 0.002
Aluminium blue flush 61-9841.6A 0.002
Aluminium green flush 61-9841.5A 0.002
Aluminium natural flush 61-9841.8A 0.002
Aluminium red flush 61-9841.2A 0.002
Aluminium yellow flush 61-9841.4A 0.002
Lens metal with window, flush mounting
Lens Ø 25 mm
Typ-Nr. e
Lens metal with window, flush mounting Aluminium black flush 61-9841.0A 0.002
Aluminium blue flush 61-9841.6A 0.002
Aluminium green flush 61-9841.5A 0.002
Aluminium natural flush 61-9841.8A 0.002
Aluminium red flush 61-9841.2A 0.002
Aluminium yellow flush 61-9841.4A 0.002
Lens metal, raised mounting
Lens Ø 24 mm
Typ-Nr. e
Lens metal, raised mounting
convex Aluminium black 61-9842.0 0.003
Aluminium blue 61-9842.6 0.003
Aluminium green 61-9842.5 0.003
Aluminium natural 61-9842.8 0.003
Aluminium red 61-9842.2 0.003
Aluminium yellow 61-9842.4 0.003
flush Aluminium black 61-9841.0 0.002
Aluminium blue 61-9841.6 0.002
Aluminium green 61-9841.5 0.002
Aluminium natural 61-9841.8 0.002
Aluminium red 61-9841.2 0.002
Aluminium yellow 61-9841.4 0.002
28
01.2009
61
Accessories
mat
Continuation see next page
Continuation see next page
Continuation see next page
Continuation see next page
Lens metal, flush mounting
Lens Ø 25 mm
Typ-Nr. e
Lens metal, flush mounting
convex Aluminium black 61-9842.0 0.003
Aluminium blue 61-9842.6 0.003
Aluminium green 61-9842.5 0.003
Aluminium natural 61-9842.8 0.003
Aluminium red 61-9842.2 0.003
Aluminium yellow 61-9842.4 0.003
flush Aluminium black 61-9841.0 0.002
Aluminium blue 61-9841.6 0.002
Aluminium green 61-9841.5 0.002
Aluminium natural 61-9841.8 0.002
Aluminium red 61-9841.2 0.002
Aluminium yellow 61-9841.4 0.002
Mushroom-head cap
Mushroom had cap Ø 32 mm
Typ-Nr. e
Mushroom-head cap Plastic black opaque 61-9593.0 0.004
Plastic green opaque 61-9593.5 0.004
Plastic red opaque 61-9593.2 0.004
Plastic yellow opaque 61-9593.4 0.004
Keylock front bezel, raised mounting
Keylock front bezel
b 24 x 24 mm
Typ-Nr.
b 18 x 18 mm
Typ-Nr.
a 18 x 24 mm
Typ-Nr. Ø 18 mm
Typ-Nr. e
Keylock front bezel,
raised mounting Plastic black 61-9250.0 61-9220.0 61-9230.0 61-9210.0 0.001
Keylock front bezel, flush mounting
Keylock front bezel
b 24 x 24 mm
Typ-Nr.
a 24 x 30 mm
Typ-Nr. Ø 25 mm
Typ-Nr. e
Keylock front bezel, flush mounting Plastic black 61-9220.0 61-9230.0 61-9210.0 0.001
29
01.2009
61
Accessories
with bar and marking dot
Continuation see next page
with bar and marking dot
Continuation see next page
for devices 25 mm dia., flush mounting
Continuation see next page
Technical drawing from page 59
Lever, raised mountin g
Lever Bar colour Typ-Nr. e
Lever, raised mounting
illuminative Plastic black blue 52-928.60 0.001
green 52-928.50 0.001
orange 52-928.30 0.001
red 52-928.20 0.001
yellow 52-928.40 0.001
Plastic grey blue 52-929.60 0.001
green 52-929.50 0.001
orange 52-929.30 0.001
red 52-929.20 0.001
yellow 52-929.40 0.001
non-illuminative Plastic black black 52-928.0 0.001
white 52-928.9 0.001
Plastic grey grey 52-929.8 0.001
white 52-929.9 0.001
Lever, flush mounting
Lever Bar colour Typ-Nr. e
Lever, flush mounting
illuminative Plastic black blue 61-9028.60 0.001
green 61-9028.50 0.001
orange 61-9028.30 0.001
red 61-9028.20 0.001
yellow 61-9028.40 0.001
Plastic grey blue 61-9029.60 0.001
green 61-9029.50 0.001
orange 61-9029.30 0.001
red 61-9029.20 0.001
yellow 61-9029.40 0.001
non-illuminative Plastic black black 61-9028.0 0.001
white 61-9028.9 0.001
Plastic grey grey 61-9029.8 0.001
white 61-9029.9 0.001
Legend frame
Typ-Nr.
Technical drawing
e
Legend frame
30 x 50 mm, adhesive, Aluminium black 61-9980.0 10 0.001
30
01.2009
61
Accessories
for Legend frame 61-9980.0
Continuation see next page
Continuation see next page
Continuation see next page
Mounting dimensions from page 58
Continuation see next page
Mounting dimensions from page 58
Legend pl at e in se rt
Typ-Nr. e
Legend plate insert
14.5 x 23.5 mm, adhesive, Aluminium black 704.968.1 0.001
14.5 x 23.5 mm, adhesive, Aluminium natural 704.968.0 0.001
Front bezel square, raised mounting
Front bezel Typ-Nr. e
Front bezel square, raised mounting
24 x 24 mm, for Selector switch Plastic black 52-950.0 0.001
26 x 26 mm, for Selector switch Plastic black 52-952.0 0.001
Front bezel set for Indicators and Illuminated pus h bu t to n , flu s h mo unting
Front bezel
b 24 x 24 mm
Typ-Nr.
a 24 x 30 mm
Typ-Nr. Ø 25 mm
Typ-Nr.
Mounting dimensions
e
Front bezel set for Indicators and
Illuminated pushbutton, flush
mounting
Plastic black 61-9930.0 61-9931.0 61-9933.10 4 0.008
Plastic silver 61-9930.4 61-9931.4 4 0.008
Aluminium black 61-9933.1 4 0.006
Aluminium natural 61-9933.0 4 0.006
Front bezel set for Mushroom-head pushbutton, flush mounting
Front bezel Ø 40 mm
Typ-Nr. Ø 32 mm
Typ-Nr.
Mounting dimensions
e
Front bezel set for Mushroom-head pushbutton, flush
mounting Aluminium natural 61-9934.8 2 0.013
Aluminium black 61-9933.1 2 0.006
Aluminium natural 61-9933.0 2 0.006
Plastic black 61-9933.10 2 0.008
31
01.2009
61
Accessories
Continuation see next page
Mounting dimensions from page 58
Continuation see next page
Mounting dimensions from page 58
Continuation see next page
Continuation see next page
ATTENTION
when using the front protection cover for push buttons the external sealing in the front bezel set and the silicone bellows
in the actuator are to be removed !
Front bezel set for Keylock switch, flush mounting
Front bezel
b 24 x 24 mm
Typ-Nr.
a 24 x 30 mm
Typ-Nr. Ø 25 mm
Typ-Nr.
Mounting dimensions
e
Front bezel set for Keylock switch,
flush mounting Plastic black 61-9930.0 61-9931.0 61-9932.10 4 0.008
Plastic silver 61-9930.4 61-9931.4 4 0.008
Aluminium black 61-9932.1 4 0.006
Aluminium natural 61-9932.0 4 0.006
Front bezel set for Selector switch, flush mounting
Front bezel
b 24 x 24 mm
Typ-Nr. Ø 25 mm
Typ-Nr.
Mounting dimensions
e
Front bezel set for Selector switch, flush mounting Plastic black 61-9936.0 4 0.007
Aluminium black 61-9932.1 4 0.006
Aluminium natural 61-9932.0 4 0.006
Plastic black 61-9932.10 4 0.008
Front ring, raised mounting
Front ring Typ-Nr. e
Front ring, raised mounting
for Actuator 24 mm dia. Aluminium black 61-9600.0 0.003
Aluminium natural 61-9600.1 0.003
Front protective cap
Front protective cap Typ-Nr. e
Front protective cap
for front bezel set 24 x 30 mm, flush mounting Silicone natural transparent 61-9927.2 0.001
for front bezel set round, flush mounting Silicone natural transparent 84-9103.7 0.001
32
01.2009
61
Accessories
Continuation see next page
Technical drawing from page 59
Continuation see next page
Mounting dimensions from page 58, Technical drawing from page 59
Continuation see next page
Mounting dimensions from page 58
Protective cover, ra ised mounting
b 24 x 24 mm
Typ-Nr.
b 18 x 18 mm
Typ-Nr.
a 18 x 24 mm
Typ-Nr.
Technical drawing
e
Protective cover, raised mounting
hinged, transparent, with means not for sealing 61-9920.0 5 0.004
hinged, transparent, with means for sealing 51-920 1 0.002
51-925 2 0.002
Protective cover, flush mounting
b 24 x 24 mm
Typ-Nr.
a 24 x 30 mm
Typ-Nr. Ø 25 mm
Typ-Nr.
Mounting dimensions
Technical drawing
e
Protective cover, flush mounting
hinged, transparent, with means for sealing 61-9921.0 460.006
61-9922.0 470.006
slide by side, with means not for sealing 61-9924.0 480.006
Blind plug, raised mounting
Blind plug
b 24 x 24 mm
Typ-Nr.
b 18 x 18 mm
Typ-Nr.
a 18 x 24 mm
Typ-Nr. Ø 18 mm
Typ-Nr.
Mounting dimensions
e
Blind plug, raised mounting Plastic black 61-9450.0 51-948.0 51-947.0 51-949.0 3 0.003
33
01.2009
61
Accessories
Continuation see next page
Mounting dimensions from page 58, Technical drawing from page 59
Continuation see next page
Continuation see next page
Other lock numbers on request
Continuation see next page
>
Continuation see next page
Terminals: ST = Screw terminal, S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm)
Component layout from page 53, Circuit drawing from page 66
Blind plug, flush mounting
Blind plug
b 24 x 24 mm
Typ-Nr.
a 24 x 30 mm
Typ-Nr. Ø 25 mm
Typ-Nr.
Mounting dimensions
Technical drawing
e
Blind plug, flush mounting Plastic black 61-9451.0 61-9452.0 4 0.006
61-9453.0 4 13 0.006
Master key
Typ-Nr. e
Master key
Lock numbers 311 ... 445 (DOM) 31-989.300 0.006
Spare key
Typ-Nr. e
Spare key
Emergency-stop, standard lock 1001 (KABA) 14-987.1001 0.006
Key lock switch, standard lock 311 (DOM) 31-989.311 0.006
EMC Key protection cap
Typ-Nr. e
EMC Key protection cap
Plastic black, for lock type DOM 31-985.0 0.005
Backside
Lamp element
Terminals
Typ-Nr.
Component layout
Circuit drawing
e
Lamp element ST 61-8006.01 31 4 0.005
S1 61-8006.02 3 4 0.005
34
01.2009
61
Accessories
Continuation see next page
Terminals: S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm)
Component layout from page 53, Circuit drawing from page 66
only for Indicator actuator
Continuation see next page
Further information in the Technical Data and Typical Applications
Terminals: S = Soldering terminal
Component layout from page 53
Diode element
Terminals
Typ-Nr.
Component layout
Circuit drawing
e
Diode element
1 Diode S1 61-8101.02 1 20 0.007
2 Diodes S1 61-8102.02 2 21 0.008
Flasher element
Terminals
Typ-Nr.
Component layout
e
Flasher element
Operation voltage : 12 ... 28 VAC/DC ±10 % S61-8000.05 30 0.005
35
01.2009
61
Accessories
Continuation see next page
We offer a Dismantling tool Typ-Nr. 61-9711.0 for dismantling of the Switching element
Diode (1N 4007): D = Diode, - = without
Switching system: SA = Snap-action switching element, SM = Slow-make switching element
Contacts: NO = Normally open, NC = Normally closed
Terminals: S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm), ST = Screw terminal
Contact material: Au/Ag = Gold/Silver, Ag = Silver, Au = Gold
Component layout from page 53, Circuit drawing from page 66
Switching element for Pushbutton | Keylock- and Selector switch 2 positions
Diode (1N 4007)
Switch rating
Switching system
Contacts
Terminals
Contact material
Typ-Nr.
Component layout
Circuit drawing
e
Switching element for
Pushbutton | Keylock-
and Selector switch
2 positions
with lamp terminal
2 D 250 VAC, 5 A SA 1 NO S1 Au/Ag 61-8212.22 36 28 0.007
Ag 61-8212.12 36 28 0.007
- 250 VAC, 5 A SM 1 NC ST Ag 61-8640.11 23 22 0.008
S1 Ag 61-8640.17 14 23 0.008
1 NC + 1 NO S1 Ag 61-8670.17 13 30 0.008
1 NO ST Ag 61-8610.11 22 27 0.008
S1 Ag 61-8610.17 11 27 0.008
2 NC S1 Ag 61-8650.17 15 24 0.008
2 NO S1 Ag 61-8620.17 12 34 0.008
SA 1 NC S1 Au/Ag 61-8440.22 4 23 0.007
Ag 61-8440.12 4 23 0.007
1 NC + 1 NO S1 Au/Ag 61-8470.22 34 30 0.007
Ag 61-8470.12 34 30 0.007
1 NC + 2 NO S1 Au/Ag 61-8490.22 35 32 0.007
Ag 61-8490.12 35 32 0.007
1 NO S1 Au/Ag 61-8410.22 28 27 0.007
Ag 61-8410.12 28 27 0.007
2 NC S1 Au/Ag 61-8450.22 5 24 0.007
Ag 61-8450.12 5 24 0.007
2 NC + 1 NO S1 Au/Ag 61-8480.22 7 31 0.007
Ag 61-8480.12 7 31 0.007
2 NO S1 Au/Ag 61-8420.22 32 34 0.007
Ag 61-8420.12 32 34 0.007
3 NC S1 Au/Ag 61-8460.22 6 25 0.007
Ag 61-8460.12 6 25 0.007
3 NO S1 Au/Ag 61-8430.22 33 35 0.007
Ag 61-8430.12 33 35 0.007
42 VAC, 100 mA SM 1 NC S1 Au 61-8640.37 14 23 0.008
1 NC + 1 NO S1 Au 61-8670.37 13 30 0.008
1 NO S1 Au 61-8610.37 11 27 0.008
2 NC S1 Au 61-8650.37 15 24 0.008
2 NO S1 Au 61-8620.37 12 34 0.008
without lamp terminal - 250 VAC, 5 A SM 1 NC ST Ag 61-8645.11 25 22 0.008
1 NC + 1 NO ST Ag 61-8675.11 26 29 0.008
1 NO ST Ag 61-8615.11 24 26 0.008
2 NC ST Ag 61-8655.11 29 36 0.008
2 NO ST Ag 61-8625.11 27 33 0.008
36
01.2009
61
Accessories
Continuation see next page
We offer a Dismantling tool Typ-Nr. 61-9711.0 for dismantling of the Switching element
Switching system: SM = Slow-make switching element, SA = Snap-action switching element
Contacts: NC = Normally closed, NO = Normally open
Terminals: S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm), ST = Screw term inal
Contact material: Ag = Silver, Au/Ag = Gold/Silver, Au = Gold
Component layout from page 53, Circuit drawing from page 66
Continuation see next page
General specifications for Switching element for Emergency-stop pushbutton : If not otherwise stated, certified according
to EN IEC 60947-5-5. Further specifications in the Technical data
Switching system: SM = Slow-make switching element
Contacts: NC = Normally closed, NO = Normally open
Terminals: ST = Screw terminal, S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm)
Contact material: Ag = Silver
Component layout from page 53, Circuit drawing from page 66
Switching element for Keylock- and Selector switch 3 positions
Switch rating
Switching system
Contacts
Terminals
Contact material
Typ-Nr.
Component layout
Circuit drawing
e
Switching element for
Keylock- and Selector switch
3 positions
with lamp terminal
250 VAC, 5 A SM 1 NC + 1 NO S1 Ag 61-8770.17 16 30 0.008
2 NC S1 Ag 61-8750.17 18 24 0.008
2 NO S1 Ag 61-8720.17 17 34 0.008
SA 1 NC + 1 NO S1 Au/Ag 61-8574.22 10 30 0.008
Ag 61-8574.12 10 30 0.008
2 NC S1 Au/Ag 61-8550.22 8 24 0.008
Ag 61-8550.12 8 24 0.008
2 NO S1 Au/Ag 61-8520.22 9 34 0.008
Ag 61-8520.12 9 34 0.008
42 VAC, 100 mA SM 1 NC + 1 NO S1 Au 61-8770.37 16 30 0.008
2 NC S1 Au 61-8750.37 8 24 0.008
2 NO S1 Au 61-8720.37 9 34 0.008
without lamp terminal 250 VAC, 5 A SM 1 NC + 1 NO ST Ag 61-8775.11 26 37 0.008
2 NC ST Ag 61-8755.11 29 36 0.008
2 NO ST Ag 61-8725.11 27 33 0.008
Switching element for Emergency-s top pushbutton, foolproof EN IEC 60947-5-5
Switch rating
Switching system
Contacts
Terminals
Contact material
Typ-Nr.
Component layout
Circuit drawing
e
Switching element for Emergency-
stop pushbutton, foolproof EN IEC
60947-5-5
250 VAC, 5 A SM 1 NC ST Ag 61-8745.11 25 38 0.008
S1 Ag 61-8745.17 20 38 0.008
1 NC + 1 NO ST Ag 61-8775.11 26 37 0.008
S1 Ag 61-8775.17 19 37 0.008
2 NC ST Ag 61-8755.11 29 36 0.008
S1 Ag 61-8755.17 21 36 0.008
37
01.2009
61
Accessories
Continuation see next page
Switching system: SM = Slow-make switching element
Contacts: NC = Normally closed, NO = Normally open
Terminals: S1 = Soldering terminal (also pluggable 2.8 x 0.5 mm)
Contact material: Au = Gold
Component layout from page 53, Circuit drawing from page 66
Continuation see next page
Terminals: P = PCB terminal
Component layout from page 53
Continuation see next page
Continuation see next page
Switching element for Stop pushbutton, foolproof
Switch rating
Switching system
Contacts
Terminals
Contact material
Typ-Nr.
Component layout
Circuit drawing
e
Switching element for Stop push-
button, foolproof 42 VAC, 100 mA SM 1 NC S1 Au 61-8745.37 20 38 0.008
1 NC + 1 NO S1 Au 61-8775.37 19 37 0.008
2 NC S1 Au 61-8755.37 21 36 0.008
PCB plug-in base
Terminals
Typ-Nr.
Component layout
e
PCB plug-in base
13.1 dia. x 12.8 mm for Indicator complete P61-9820.1 37 0.002
15 x 23 x 9.4 mm for Snap-action Switching element, Indicator- and Diode element, Pins axial P 61-9821.1 38 0.003
17.7 x 23.6 x 10.9 mm for Slow-make Switching element, Pins axial P 61-9823 39 0.002
Multi-plug housing
Typ-Nr. e
Multi-plug housing
for Snap-action Switching element, max. 6 connections possible 61-9830 0.002
Flat receptacle
Typ-Nr. e
Flat receptacle
2.8 x 0.5 mm for Multi-plug housing 51-943.1 0.001
2.8 x 0.5 mm for Plug-in terminal 31-946 0.001
38
01.2009
61
Accessories
Continuation see next page
Continuation see next page
>
Continuation see next page
Insulation sleeve
Typ-Nr. e
Insulation sleeve
for Flat receptacles 31-946 31-929 0.001
Terminal cover
Typ-Nr. e
Terminal cover
for Indicator complete 61-9831.2 0.001
for Snap-action Switching element with soldering terminal 61-9830.2 0.002
Illumination
Filament lamp
Socket Operating voltage/-current Typ-Nr. e
Filament lamp T1 3/4 MG 12 VAC/DC, 75 mA 10-1309.1309 0.001
14 VAC/DC, 80 mA 10-1310.1319 0.001
18 VAC/DC, 40 mA 10-1311.1249 0.001
24 VAC/DC, 35 mA 10-1312.1229 0.001
28 VAC/DC, 30 mA 10-1313.1209 0.001
28 VAC/DC, 40 mA 10-1313.1249 0.001
36 VAC/DC, 20 mA 10-1316.1179 0.001
36 VAC/DC, 30 mA 10-1316.1209 0.001
48 VAC/DC, 20 mA 10-1319.1179 0.001
48 VAC/DC, 25 mA 10-1319.1199 0.001
6 VAC/DC, 120 mA 10-1306.1349 0.001
6.3 VAC/DC, 200 mA 10-1307.1369 0.001
39
01.2009
61
Accessories
Continuation see next page
Note:
AC operation through halve-wave rectifier possible, slight flickering can occure.
for fitting with series resistors
Continuation see next page
>
Mounting hole size 16 mm dia.
Continuation see next page
Single-LED
Socket Light colour Operating voltage/-current Typ-Nr. e
Single-LED T1 3/4 MG blue 12 VAC/DC, 7/14 mA 10-2J09.1066 0.002
24 VAC/DC, 7/14 mA 10-2J12.1066 0.002
28 VAC/DC, 7/14 mA 10-2J13.1066 0.002
48 VAC/DC, 4/8 mA 10-2J19.1046 0.002
6 VDC, 15 mA 10-2J06.3146 0.002
green 12 VAC/DC, 4/7 mA 10-2J09.1065 0.002
24 VAC/DC, 4/7 mA 10-2J12.1065 0.002
28 VAC/DC, 4/7 mA 10-2J13.1065 0.002
48 VAC/DC, 2/4 mA 10-2J19.1045 0.002
6 VDC, 7 mA 10-2J06.3145 0.002
red 12 VAC/DC, 7/14 mA 10-2J09.1062 0.002
24 VAC/DC, 7/14 mA 10-2J12.1062 0.002
28 VAC/DC, 7/14 mA 10-2J13.1062 0.002
48 VAC/DC, 4/8 mA 10-2J19.1042 0.002
6 VDC, 15 mA 10-2J06.3142 0.002
white diffuse 12 VAC/DC, 7/14 mA 10-2J09.1069 0.002
24 VAC/DC, 7/14 mA 10-2J12.1069 0.002
28 VAC/DC, 7/14 mA 10-2J13.1069 0.002
48 VAC/DC, 4/8 mA 10-2J19.1049 0.002
6 VDC, 15 mA 10-2J06.3149 0.002
yellow 12 VAC/DC, 7/14 mA 10-2J09.1064 0.002
24 VAC/DC, 7/14 mA 10-2J12.1064 0.002
28 VAC/DC, 7/14 mA 10-2J13.1064 0.002
48 VAC/DC, 4/8 mA 10-2J19.1044 0.002
6 VDC, 15 mA 10-2J06.3144 0.002
Terminal plate empty
Typ-Nr. e
Terminal plate empty
10 spaces 125 x 60 x 15 mm 02-912.2 0.045
15 spaces 187.5 x 60 x 15 mm 02-912.3 0.090
20 spaces 250 x 60 x 15 mm 02-912.4 0.095
5 spaces 62.5 x 60 x 15 mm 02-912.1 0.025
Emergency-stop pushbutton
Emergency-stop label
Marking Typ-Nr. e
Emergency-stop label
43 mm dia., yellow ARRET-D´URGENCE 61-9970.3 0.002
EMERGENCY-STOP 61-9970.2 0.002
NOT-AUS 61-9970.1 0.002
NOT-HALT 61-9970.6 0.002
without marking 61-9970.0 0.002
40
01.2009
61
Accessories
Continuation see next page
Technical drawing from page 59
Bottom grey similar RAL 7035; cover lead-sealable, yellow similar RAL 1004
Continuation see next page
Openings for cable gland M16 or M20.
Protection class IP 66.
Technical drawing from page 59
Continuation see next page
with traction relief; protection degree IP 68.
>
Continuation see next page
Emergency-stop protective shroud
Typ-Nr.
Technical drawing
e
Emergency-stop protective shroud
Aluminium anodized, yellow varnished 61-9965 11 0.036
Emergency-stop enclosures
Dimension Typ-Nr.
Technical drawing
e
Emergency-stop enclosures
with mounting hole size 16 mm dia., without anti- twist device L 65 mm, W 65 mm, H 57 mm 61-9480.5 12 0.099
Cable gland
Typ-Nr. e
Cable gland
M16, Plastic grey 61-9481.6 0.007
M20, Plastic grey 704.945.6 0.011
Assembling
Fixing nut
Typ-Nr. e
Fixing nut
Metal, specifically for keylock switches 31-991 0.005
Plastic, standard delivery 61-9915.0 0.002
41
01.2009
61
Accessories
Continuation see next page
without Keylock- and Selector switch
Continuation see next page
consists of Lens remover, Lamp-and LED remover, Mounting tool, Dismantling tool
Continuation see next page
for dismantling keep care of the enclosed Packing insert
Continuation see next page
Continuation see next page
CAUTION
A switching process might be released when replacing the lamp/LED !
Continuation see next page
Anti-twist ring
Typ-Nr. e
Anti-twist ring
Mounting hole size 16 mm dia. 51-910 0.001
Mounting hole size 22.5 mm dia. 61-9912.0 0.002
Reducing ring
Typ-Nr. e
Reducing ring
only for use of devices with Front size 24 x 24 mm and 24 mm dia., Mounting hole size 22.5 mm dia.
to 16.5 mm dia.
61-9960 0.003
Tool set
Typ-Nr. e
Tool set K61-999.100 0.048
Lens remover
Typ-Nr. e
Lens remover
for flush mounting 61-9730.0 0.011
for raised mounting 02-905 0.011
Lamp remover
Typ-Nr. e
Lamp remover 61-9740.0 0.003
Mounting tool
Typ-Nr. e
Mounting tool
for Indicator 16 mm dia. 01-907 0.020
42
01.2009
61
Accessories
Continuation see next page
Continuation see next page
Grey similar RAL 7035; cover lead-sealable
Continuation see next page
Openings for cable gland M16 or M20.
Protection class IP 66.
Technical drawing from page 59
Continuation see next page
with traction relief; protection degree IP 68.
Dismantling tool
Typ-Nr. e
Dismantling tool
for dismantling of the Switching element 61-9711.0 0.004
Flat receptacle remover
Typ-Nr. e
Flat receptacle remover
for removing the Flat receptacle of the Multi-plug in housing 51-943.9 0.001
Enclosure
Dimension Typ-Nr.
Technical drawing
e
Enclosure
with mounting hole size 16 mm dia., without anti- twist device L 65 mm, W 65 mm, H 57 mm 61-9480.6 12 0.099
Cable gland
Typ-Nr. e
Cable gland
M16, Plastic grey 61-9481.6 0.007
M20, Plastic grey 704.945.6 0.011
43
01.2009
61
Technical Data
Switching system
Self-cleaning, double-break snap-action switching system with
contact opening width 2 x 0.5 mm (switch with small contact
opening width as per EN IEC 61058-1).
The switching elements are optionally equipped with the following
switching functions :
One to three normally open (NO) or normally closed (NC), or any
combination of NO and NC plus connections for T1 3/4 LED or lamp.
The number of switching elements cannot exceed three.
The switching elements provided for the 3-position switch actuators
are equipped with max. 2 NC or 2 NO or any combination. The
number of switching elements cannot exceed two.
Material
Lens
Raised mounting Polymethylmethacrylat (PMMA), as per UL 94
HB, flush mounting Polycarbonat (PC), as per UL 94 V0, or
Aluminium anodized
Front bezel
Polyetherimid (PEI), as per UL 94 V0, or Aluminium anodized
Front ring
Aluminium anodized
Material of contact
Silver or silver with gold plating
Switching element
Diallylphthalate (DAP), as per UL 94 V0 and Polyamide (PA 66), as
per UL 94 V0
Actuator housing
Polyetherimide (PEI), as per UL 94 V0, self-extinguishing
Mechanical characteristics
Terminals
0
Actuating torque
0
Actuating force
0
Actuating travel
0
0
Rebound time
The rebound times apply to normal manual activation
0
Mechanical lifetime
as per DIN IEC 60512-5-6 and EN IEC 60947-5-1
0
Electrical characteristics
Standards
The devices comply with : EN IEC 61058-1 and EN IEC 60947-5-1
Rated Operational Voltage Ue
250 VAC/DC as per EN IEC 60947-1
Rated Insulation Voltage Ui
320 VAC, as per EN IEC 60947-5-1
Rated Impulse Withstand Voltage Uimp
4 kV, as per EN IEC 60947-5-1
Contact resistance
New state with silver contact 100 mΩ
as per DIN IEC 60512-2-4, measured at 100 mA, 10 V
New state with gold plated contact 50 mΩ
as per DIN IEC 60512-2-3, measured at 20 mV, 10 mA
Electrical life
50.000 cycles of operation at 250 VAC, 5 A, cosφ 0.95, as per EN
IEC 60947-5-1
Electrostatic discharge (ESD)
0
Conventional free air thermal current Ith
5 A, as per EN IEC 60947-5-1
the maximum current in continuous operation and at ambient
temperature must not exceed the quoted maximum values.
Switch rating
Switch rating AC with silver contact or silver contact with gold
plating, service category AC-15, as per EN IEC 60947-5-1
0
Switch rating DC for silver contact or silver contact with gold plating,
service category DC-13, as per EN IEC 60947-5-1
0
Recommended minimum operational data
0
Electric strength
2500 VAC, 50 Hz, 1 min., as per DIN IEC 60512-2-11
between all terminals and earth
Overvoltage category
III, as per EN IEC 60947-5-1
Protection class
Class II, as per EN IEC 61058-1
Degree of pollution
3, as per EN IEC 60947-1
Actuator with snap-action switching element
- Solder rigid flexible superflexible
1 wire 0.5 ... 1.5 mm² 0.5 ... 0.75 m 0.5 mm²
2 wires 0.75 mm² 0.5 mm²
Selector-/ Keylock switch 2.5 ... 10 Ncm
Pushbutton 2.7 ... 3.6 N
Pushbutton 3 mm
Selector-/ keylock switch 2 positions 3 positions
Momentary action approx. 42 ° approx. 2 x 42 °
Maintained action approx. 90 ° approx. 2 x 90 °
Contact making 3 ms
Contact breaking 5 ms
Pushbutton maintained action 1 million cycles of operation
Pushbutton momentary action 2 million cycles of operation
Emergency-stop switch 6 050 cycles of operation
Keylock switch 50 000 cycles of operation
Selector switch 100 000 cycles of operation
Keylock switch 11 kV
Voltage 125 VAC 250 VAC
Current 2.5 A 2 A
Voltage 250 VDC
Current 0.15 A
Material of contact Silver Silver with gold plating
Voltage 20 VAC/DC 5 VAC/DC
Current 100 mA 10 mA
44
01.2009
61
Technical Data
Environmental conditions
Storage temperature
-40 °C ... +85 °C
Operating temperature
-25 °C ... +55 °C
Protection degree
as per EN IEC 60529
Frontside IP 65 | backside IP 40
Shock resistance
(semi-sinusoidal)
max. 100 m/s², pulse width 11 ms, 3-axis, as per EN IEC 60068-2-
27
Vibration resistance
(sinusoidal)
max. 100 m/s² at 10 Hz ... 500 Hz, as per EN IEC 60068-2-6
Climate resistance
Damp heat, cyclic
96 hours, +25 °C / 97 %, +55 °C / 93 % relative humidity, as per EN
IEC 60068-2-30
Damp heat, state
56 days, +40 °C / 93 % relative humidity, as per EN IEC 60068-2-78
Rapid change of temperature
100 cycles, -40 °C ... +80 °C, as per EN IEC 60068-2-14
Approvals
Approbations
CB (IEC 61058)
CB (IEC 60947)
CSA
ENEC (EN 61058)
Germanischer Lloyd
GOST
UL
VDE
Declaration of conformity
CE
RoHS
>
Switching system
Double-break slow-make system, contact opening width 2 x 1.5
mm, with 2 x 2 contact points per switching element.
NC-contact elements in the slow-make elements fulfill requirements
of switches with forced opening as per EN IEC 60947-5-1 2.17
The slow-make elements are optionally obtainable with the
following switching functions : 1 NO or 2 NO, 1 NC or 2 NC, 1 NO +
1 NC.
Material
Lens
Raised mounting Polymethylmethacrylat (PMMA), as per UL 94
HB, flush mounting Polycarbonat (PC), as per UL 94 V0, or
Aluminium anodized
Front bezel
Polyetherimid (PEI), as per UL 94 V0, or Aluminium anodized
Front ring
Aluminium anodized
Material of contact
Silver or gold (specified for operation for low level switching)
Switching element
Diallylphthalate (DAP), as per UL 94 V0 and Polyamide (PA 66), as
per UL 94 V0
Actuator housing
Polyetherimide (PEI), as per UL 94 V0, self-extinguishing
Mechanical characteristics
Terminals
0
0
Actuating torque
0
Actuating force
0
Actuating travel
0
0
Rebound time
2 ms, contact making and contact breaking
the rebound times apply to normal manual activation
Mechanical lifetime
as per DIN IEC 60512-5-6 and EN IEC 60947-5-1
0
Electrical characteristics
Standards
The devices comply with : EN IEC 61058-1 and EN IEC 60947-5-1,
EN IEC 60947-5-5 (Emergency-stop)
Electrical life
50.000 cycles of operation at 250 VAC, 5 A, cosφ 0.95, as per EN
IEC 60947-5-1
Switching Element of Emergency-stop 6050 cycles of operation, as
per EN IEC 60947-5-5
Electrostatic discharge (ESD)
0
Electric strength
4000 VAC, 50 Hz, 1 min., as per DIN IEC 60512-2
between all terminals and earth
Actuator with slow-make switching element
- Solder rigid flexible superflexible
1 wire 0.5 ... 1.5 mm² 0.5 ... 0.75 mm² 0.5 mm²
2 wires 0.75 mm² 0.5 mm²
- Screw
1 wire 0.5 ... 1.5 mm² 0.5 ... 0.75 mm² 0.5 mm²
2 wires 0.75 mm² 0.5 mm² 0.5 mm²
Selector-/ Keylock switch 4 ... 16 Ncm
Pushbutton 3.5 ... 11 N
Emergency-stop switch max. 65 N
Pushbutton 3 mm
Emergency-stop switch 10 mm
Selector-/ keylock switch 2 positions 3 positions
Momentary action approx. 42 ° approx. 2 x 42 °
Maintained action approx. 90 ° approx. 2 x 90 °
Pushbutton maintained action 1 million cycles of operation
Pushbutton momentary action 2 million cycles of operation
Emergency-stop switch 6 050 cycles of operation
Keylock switch 50 000 cycles of operation
Selector switch 100 000 cycles of operation
Keylock switch 11 kV
45
01.2009
61
Technical Data
Overvoltage category
III, as per EN IEC 60947-5-1
Protection class
Class II, as per EN IEC 61058-1
Degree of pollution
3, as per EN IEC 60947-1
Electrical characteristics for silver contacts
Rated Operational Voltage Ue
250 VAC/DC as per EN IEC 60947-1
Rated Insulation Voltage Ui
320 VAC, as per EN IEC 60947-5-1
Rated Impulse Withstand Voltage Uimp
4 kV, as per EN IEC 60947-5-1
Contact resistance
New state 50 mΩ, as per DIN IEC 60512-2-4, measured at
100 mA, 10 V
Conventional free air thermal current Ith
5 A, as per EN IEC 60947-5-1
the maximum current in continuous operation and at ambient
temperature must not exceed the quoted maximum values.
Switch rating
Switch rating AC with silver contact and srew terminal, service
category AC-15, as per EN IEC 60947-5-1
0
Switch rating with silver contact and screw terminal, service
category DC-13, as per EN IEC 60947-5-1
0
Recommended minimum operational data
20 VAC/DC, 100 mA
Electrical characteristics for gold contacts
Rated Operational Voltage Ue
50 VAC/DC, as per EN IEC 60947-5-1
Rated Insulation Voltage Ui
Ui = 320 VAC, as per EN IEC 60947-5-1
Rated Impulse Withstand Voltage Uimp
0.8 kV, as per EN IEC 60947-1
Contact resistance
New state 50 mΩ
as per DIN IEC 60512-2-4, measured at 20 mV, 10 mA
Conventional free air thermal current Ith
3 A, as per EN IEC 60947-5-1
the maximum current in continuous operation and at ambient
temperature must not exceed the quoted maximum values.
Switch rating
Switch rating AC with gold contact, service category AC-15, as per
EN IEC 60947-5-1
0
Switch rating with gold contact, service category DC-13, as per EN
IEC 60947-5-1
0
Recommended minimum operational data
0
Environmental conditions
Storage temperature
-40 °C ... +85 °C
Operating temperature
-25 °C ... +55 °C
Protection degree
as per EN IEC 60529
Frontside IP 65 | backside IP 40
Shock resistance
(semi-sinusoidal)
max. 100 m/s², pulse width 11 ms, 3-axis, as per EN IEC 60068-2-
27
Vibration resistance
(sinusoidal)
max. 100 m/s² at 10 Hz ... 500 Hz, as per EN IEC 60068-2-6
Climate resistance
Damp heat, cyclic
96 hours, +25 °C / 97 %, +55 °C / 93 % relative humidity, as per EN
IEC 60068-2-30
Damp heat, state
56 days, +40 °C / 93 % relative humidity, as per EN IEC 60068-2-78
Rapid change of temperature
100 cycles, -40 °C ... +80 °C, as per EN IEC 60068-2-14
Approvals
Approbations
CB (IEC 61058)
CB (IEC 60947)
ENEC (EN 61058)
Germanischer Lloyd
GOST
SEV
UL
VDE
Declaration of conformity
CE
RoHS
Voltage 125 VAC 250 VAC
Current 3 A 2 A
Voltage 250 VDC
Current 0.2 A
Voltage 50 VAC
Current 0.5 A
Voltage 50 VDC
Current 0.1 A
Voltage 10 mVAC/DC
Current 2 mA
46
01.2009
61
Technical Data
>
Material
Lens
Raised mounting Polymetylmethacrylat PMMA, as per UL 94 HB,
flush mounting Polycarbonat (PC), as per UL 94 V0
Actuator housing
Polyetherimide (PEI), as per UL 94 V0, self-extinguishing
Flasher element
Polyetherimide (PEI), as per UL 94 V0
Mechanical characteristics
Terminals
Soldering terminal
Electrical characteristics
Illumination
0
0
Flashing frequency
1 Hz ±0.25 Hz
Pulse duty factor
approx. 50 %
Operating voltage
12 ... 28 VAC/DC ±10 %
Environmental conditions
Operating temperature
0 °C ... +45 °C
Protection degree
as per EN IEC 60529
Frontside IP 65 | backside IP 40
Actuator with flasher element
Filament lamp 14 V AC/DC 28 VAC/DC
Power consumption 80 mA 44 mA
Single-LED 12 VAC/DC 28 VAC/DC
Power consumption 15 mA 18 mA
61
Typical Applications
47
01.2009
When indicators and illuminated pushbuttons equipped with diodes, the user is able to perform a lamp check or wire an alarm
circuit simply with a considerable saving of space.
0
Diode element
61
Typical Applications
48
01.2009
>
Do not connect terminal B and D simultaneously when powered up. When operating with DC voltage terminal
G must have positive polarity.
0
Flasher element
B
D
G
V
sB
D
G
B
D
G
Continuous light Flashing light Flashing- or continuous light
61
Application guidelines
49
01.2009
When switching inductive loads such as relays, DC motors, and DC soleno ids, it is always important
to absorb surges (e.g. with a diode) to protect the contacts. When these inductive loads are switched
off, a counter emf can severely damage switch contacts and greatly shorten lifetime.
Fig. 1 shows an inductive load with a free-wheeling diode connected in parallel. This free-wheeling
diode provides a path for the inductor current to flow when the current is interrupted by the switch.
Without this free-wheeling diode, the voltage across the coil will be limited only by dielectric break-
down voltages of the circuit or parasitic elements of the coil. This voltage can be kilovolts in amplitude
even when nominal circuit voltages are low (e.g. 12 VDC) see Fig. 2.
The free-wheeling diode should be chosen so that the reverse breakdown voltage is greater than the
voltage driving the inductive load. The DC blocking voltage (VR) of the free-wheeling diode can be
found in the datasheet of a diode. The forward current should be equal or greater than the maximum
current flowing through the load.
To get an efficient protection, the free-wheeling diode must be connected as close as possible
to the inductive load!
0
Suppressor circuits
Sveral hundred
to several
thousend volts
ON OFF
0
e = L di
dt
__
VDC
Switch
Free-wheeling
diode
Inductive
load
Counter emf
over load without free-wheeling diode
Fig. 2
Switching with inductive load
Fig. 1
+
_
61
Marking
50
01.2009
0
>
All dimensions in mm
0
0
>
General notes
1. Engraving
In addition to the most commonly used world
languages, in DIN 1451-3 close spacing, other
typefaces are available as Scandinavian,
Slavic, Greek, Russian and Polish.
Red, blue and black lenses are filled with white
colour. Other colour lenses are filled in black.
Standard height of letters is 2 mm. If the height
is not specified, we will supply 2 mm engraved
letters.
2. Hot stamping
For larger series it is worth considering
markings by means of hot stamping or laser
engraving. We will pleased to advise you.
For letters and figures, typefaces with 2.5 mm,
3 mm and 4 mm are available.
3. Film inserts
Instead of using engraving the lenses can be
fitted with transparent film inserts, as an
alternative.
In the case of use of a smoke-black lens the
fitted film becomes readable only if the lamp is
on.
The film thickness is 0.2 mm.
For lenses 24 mm and 25 mm dia. with Typ-
Nr. 619642.x the marking takes place directly
on the text plate Typ-Nr. 61-9707.7, instead of
a film insert.
Important : Consider pushbutton mounting
orientation before specifying engraving
characters !
Lenses for Indicators | Illuminated pushbuttons, flush mounting
Front size
(Lens) Film insert
max. size Height of letters
hNumber of lines Number of (target value)
capital letters per line Number of (target value)
small letters per line Image
24 x 24
(18 x 18) 15.1 x 15.1 2 4 8 - 9 9 B3
337 - 8 8 B3
424 - 5 5 B3
524 4 - 5 B3
6144B3
812 - 3 2 - 3 B3
24 x 30
(18 x 24) 15.1 x 21 2 4 12 13 B1
58 - 9 9 B2
3 3 10 - 11 11 - 12 B1
47 - 8 8 B2
4278B1
34 - 5 5 B2
525 - 6 6 B1
44 - 5B2
614 - 5 5 B1
23 3 - 4 B2
813 - 4 3 - 4 B1
2 - 3 2 - 3 B2
25 dia.
(19.7 dia.) Marking plate 2 3 6 6 B4
3256B4
4234B4
5123B4
6123B4
8122B4
B1 B2 B4B3
h
Engraving
Film
AB
abc abc
AB
abc
AB
abc
AB
61
Marking
51
01.2009
All dimensions in mm
0
0
>
Lenses for Indicators | Illuminated pushbuttons, raised mounting
Front size
(Lens) Film insert
max. size Height of letters
hNumber of lines Number of (target value)
capital letters per line Number of (target value)
small letters per line Image
18 dia.
(15.8 dia.) 12.8 dia. 2 6 6 B4
325 6 B4
423 4 B4
512 3 B4
612 3 B4
812 2 B4
18 x 18
(15.3 x 15.3) 12.7 x 12.7 2 4 7 - 8 8 B3
336 - 7 7 B3
424 - 5 5 B3
523 - 4 4 B3
613 3 - 4 B3
812 - 3 2 - 3 B3
18 x 24
(15.3 x 21.5) 12.7 x 18.7 2 4 11 12 B1
57 - 8 8 B2
3 3 9 -10 10 - 11 B1
46 - 7 7 B2
427 7 - 8 B1
34 - 5 5 B2
525 - 6 6 B1
3 - 4 4 B2
614 - 5 5 B1
23 3 - 4 B2
813 - 4 3 - 4 B1
2 - 3 2 - 3 B2
24 dia.
(19.7 dia.) Marking plate 2 3 6 6 B4
325 6 B4
423 4 B4
512 3 B4
612 3 B4
812 2 B4
24 x 24
(20 x 20) 16.9 x 16.9 2 4 9 10 B3
337 - 8 9 B3
424 - 5 5 B3
524 4 - 5 B3
614 4 B3
812 2 B3
61
Marking
52
01.2009
All dimensions in mm
0
0
Engraving legend plates
Height of letters
hNumber of lines Number of (target value)
letters per line
3.0 1 11
3.0 2 11
4.0 1 7
8.0 1 4
50
h
30
Ø25
61
Drawings
53
01.2009
1 Diode element page 34
2 Diode element page 34
3 Lamp element page 33
4 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
5 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
6 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
7 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
8 Switching element for Keylock- and Selector switch 3 positions page 36
Component layout
61
Drawings
54
01.2009
9 Switching element for Keylock- and Selector switch 3 positions page 36
10 Switching element for Keylock- and Selector switch 3 positions page 36
11 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
12 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
13 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
14 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
15 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
16 Switching element for Keylock- and Selector switch 3 positions page 36
61
Drawings
55
01.2009
17 Switching element for Keylock- and Selector switch 3 positions page 36
18 Switching element for Keylock- and Selector switch 3 positions page 36
19 Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36 | Switching element for Stop pushbutton,
foolproof page 37
20 Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36 | Switching element for Stop pushbutton,
foolproof page 37
21 Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36 | Switching element for Stop pushbutton,
foolproof page 37
22 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
23 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
61
Drawings
56
01.2009
24 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
25 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Emergency-stop
pushbutton, foolproof EN IEC 60947-5-5 page 36
26 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Keylock- and Selector
switch 3 positions page 36 | Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36
27 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Keylock- and Selector
switch 3 positions page 36
28 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
29 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Keylock- and Selector
switch 3 positions page 36 | Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36
30 Flasher element page 34
31 Lamp element page 33
61
Drawings
57
01.2009
32 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
33 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
34 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
35 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
36 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
37 PCB plug-in base page 37
Libraries for the PCB layout-system p-cad 200X see : www.pcad.com/recources/libraries Third-party Libraries
38 PCB plug-in base page 37
Libraries for the PCB layout-system p-cad 200X see : www.pcad.com/recources/libraries Third-party Libraries
61
Drawings
58
01.2009
39 PCB plug-in base page 37
Libraries for the PCB layout-system p-cad 200X see : www.pcad.com/recources/libraries Third-party Libraries
40 Potentiometer, flush mounting page 24
1 Emergency-stop pushbutton actuator, foolproof EN IEC 60947-5-5 page 13 | Stop pushbutton actuator, foolproof page 14 | Mushroom-
head pushbutton actuator page 14
2 Mushroom-head pushbutton actuator, flush mounting page 20 | Front bezel set for Mushroom-head pushbutton, flush mounting page
30
Mounting dimensions
ac
b
Rearview
Potentiometer terminals
Conductor colour of flat ribbon cable
a = blue, b = red, c = yellow
16
+
0.2
0
1.7
0
-
0.1
Ø32 = 35 min.
Ø27 = 45 min.
Ø32 = 32 min.
Ø27 = 45 min.
15 +
0.05
0
Ø27 mm
Ø32 mm
Ø40 = 40 min.
Ø32 = 35 min.
Ø32 mm
Ø40 mm
22.3
+
0.4
0
Ø40 = 40 min.
Ø32 = 32 min.
61
Drawings
59
01.2009
3 Indicator complete page 11 | Indicator actuator page 11 | Illuminated pushbutton actuator page 12 | Keylock switch actuator 2 positions
page 15 | Keylock switch actuator 3 positions page 16 | Selector switch actuator 2 positions page 17 | Selector switch actuator 3 positions
page 18 | Blind plug, raised mounting page 32
4 Indicator complete, flush mounting page 19 | Indicator actuator, flush mounting page 19 | Illuminated pushbutton actuator, flush
mounting page 20 | Keylock switch actuator 2 positions, flush mounting page 21 | Keylock switch actuator 3 positions, flush mounting
page 22 | Selector switch actuator 2 positions, flush mounting page 23 | Selector switch actuator 3 positions, flush mounting page 24 |
Potentiometer, flush mounting page 24 | Front bezel set for Indicators and Illuminated pushbutton, flush mounting page 30 | Front bezel
set for Keylock switch, flush mounting page 31 | Front bezel set for Selector switch, flush mounting page 31 | Protective cover, flush
mounting page 32 | Blind plug, flush mounting page 33
- Hole spacing min. 26 mm / min. 26 mm by using of the round front protective cap 84-9103.7
- Hole spacing min. 31 mm / min. 25 mm by using of the rectangular fr ont protectice cap 61-9927.2
1 Protective cover, raised mounting page 32
2 Protective cover, raised mounting page 32
Technical drawing
Ø18 mm 18 x 18 mm Ø24 mm
18 x 24 mm 24 x 24 mm
15 +
0.05
0
24 min.
35 min. with screw terminal
35 min. with screw terminal 35 min. with screw terminal
18 min.
18 min.
24 min.
24 min.24 min.
16 +
0.2
0
1.7
0
-
0.1
25 min.
30 min.
24 min.
25 min.
Ø25 mm
22.3 +
0.4
0
27 +
0.25
-
0.15
21 +
0.25
-
0.15
24 min.
24 min.
24 x 30 mm 24 x 24 mm
21 +
0.25
-
0.15
21 +
0.25
-
0.15
35 min. with screw terminal
35 min. with screw terminal 35 min. with screw terminal
10.5
25.5
20
23.5
14.5
32
14.5
32
24
23.5
25.5
10.5
61
Drawings
60
01.2009
3 Indicator complete pag e 11
4 Indicator complete, flush mounting page 19
5 Protective cover, raised mounting page 32
6 Protective cover, flush mounting page 32
7 Protective cover, flush mounting page 32
Ø 24 mm 24 x 24 mm
Ø 18 mm 18 x 18 mm
18 x 24 mmm
2.8 x 0.5
8 max.
10.6 42
Ø 25 mm 24 x 24 mm
24 x 30 mm
5.5 max.
249
2.8 x 0.5
39.7
14.726.4
29
13.25
245.5 max.
24
25
12
4.5
245.5 max.
30
25
12
4.5
61
Drawings
61
01.2009
8 Protective cover, flush mounting page 32
9 Potentiometer, flush mounting page 24
10 Legend frame page 29
11 Emergency-stop protective shroud page 40
12 Emergency-stop enclosures page 40 | Enclosure page 42
Ø25
42
29.3 1.5 min.
5.5 max.
10
4 max.
23 max.
12
Ø16
300 24 x 24 mm Ø 25 mm
14.5
50
30
23.5
4
Ø25
16
35
3
+
0.3
0
Ø48
Ø40
57
65
50
50
25
65
61
Drawings
62
01.2009
13 Blind plug, flush mounting page 33
14 Indicator actuator page 11
15 Mushroom-head pushbutton actuator page 14
25
1...5
23.5
2
16.5 min.
20.5 max.
Soldering terminal Screw terminalSoldering terminal Soldering terminal
Diode element Lamp elementLamp element Flasher element
Ø 24 mm
Ø 18 mm 18 x 18 mm18 x 24 mm 24 x 24 mm
10.6
Ø14.5
2.8 x 0.5
2.8 x 0.5
24
8 max.
18
42 46 6542
Snap-action switching element
Soldering terminal
Low-make switching element
Soldering terminal
Low-make switching element
Screw terminal
Ø 32 mm
44 46
42
18.1
2.8 x 0.5
24
8 max.
18
2.8 x 0.5
61
Drawings
63
01.2009
16 Illuminated pushbutton actuator page 12
17 Keylock switch actuator 2 positions page 15 | Keylock switch actuator 3 positions page 16
18 Selector switch actuator 2 positions page 17 | Selector switch actuator 3 positions page 18
Snap-action switching element
Soldering terminal
Slow-make switching element
Screw terminal
Slow-make switching element
Soldering terminal
Ø 24 mm 24 x 24 mm
Ø 18 mm 18 x 18 mm
18 x 24 mm
10.6 42 4644
2.8 x 0.5
2.8 x 0.5
24
8 max.
18
Snap-action switching element
Soldering terminal
Slow-make switching element
Screw terminal
Slow-make switching element
Soldering terminal
35 42 4644
2.8 x 0.5
2.8 x 0.5
24
6.5 max.
18
24 x 24 mm
Ø 18 mm 18 x 18 mm
18 x 24 mm
10
Snap-action switching element
Soldering terminal
Slow-make switching element
Soldering terminal
Slow-make switching element
Screw terminal
Ø 18 mm 26 x 26 mm
24 x 24 mm
44 46
42
14
2.8 x 0.5
2.8 x 0.5
24
max. 8
18
7
61
Drawings
64
01.2009
19 Emergency-stop pushbutton actuator, foolproof EN IEC 60947-5-5 page 13 | Stop pushbutton actuator, foolproof page 14
20 Illuminated pushbutton actuator, flush mounting page 20
21 Indicator actuator, flush mounting page 19
Ø 27 mm Ø 27 mm
Slow-make switching element
Soldering terminal
Slow-make switching element
Screw terminal
59.5 44 46
2.8 x 0.5
24
33.5
18
max. 6
Snap-action switching element
Soldering terminal
Slow-make switching element
Screw terminal
Slow-make switching element
Soldering terminal
5.5 max.
249 54
2.8 x 0.5
2.8 x 0.5
24
18
52
Ø 25 mm 24 x 24 mm24 x 30 mm
Diode element
Soldering terminal
Lamp element
Screw terminal
Lamp element
Soldering terminal
Flasher element
Soldering terminal
Ø 25 mm 24 x 24 mm
24 x 30 mm
5.5 max.
249 54 73
24
18
49
2.8 x 0.5
2.8 x 0.5
Ø14.5
61
Drawings
65
01.2009
22 Keylock switch actuator 2 positions, flush mounting page 21 | Keylock switch actuator 3 positions, flush mounting page 22
23 Selector switch actuator 2 positions, flush mounting page 23 | Selector switch actuator 3 positions, flush mounting page 24
24 Mushroom-head pushbutton actuator, flush mounting page 20
Snap-action switching element
Soldering terminal
Slow-make switching element
Screw terminal
Slow-make switching element
Soldering terminal
Ø 25 mm 24 x 24 mm
24 x 30 mm
49
27
2
2.8 x 0.5
2.8 x 0.5
24
5.5 max.
18
54
52
Snap-action switching element
Soldering terminal
Slow-make switching element
Screw terminal
Slow-make switching element
Soldering terminal
Ø 25 mm 24 x 24 mm
5.5 max.
249 54
24
18
51
7
2.8 x 0.5
2.8 x 0.5
Ø 32 mm
Snap-action switching element
Soldering terminal
Slow-make switching element
Screw terminal
Slow-make switching element
Soldering terminal
5.5 max.
249 54
24
18
52
10
2.8 x 0.5
2.8 x 0.5
61
Drawings
66
01.2009
1 Potentiometer, flush mounting page 24
2 Mushroom-head pushbutton actuator page 14 | Illuminated pushbutton actuator, flush mounting page 20 | Mushroom-head pushbutton
actuator, flush mounting page 20
3 Mushroom-head pushbutton actuator page 14 | Illuminated pushbutton actuator, flush mounting page 20 | Mushroom-head pushbutton
actuator, flush mounting page 20
4 Indicator complete page 11 | Indicator actuator page 11 | Indicator complete, flush mounting page 19 | Indicator actuator, flush mounting
page 19 | Lamp element page 33
5 Emergency-stop pushbutton actuator, foolproof EN IEC 60947-5-5 page 13 | Stop pushbutton actuator, foolproof page 14
6 Illuminated pushb utton actuator page 12
7 Selector switch actuator 2 positions page 17 | Selector switch actuator 2 positions, flush mounting page 23
8 Selector switch actuator 2 positions page 17 | Selector switch actuator 2 positions, flush mounting page 23
9 Selector switch actuator 3 positions page 18 | Selector switch actuator 3 positions, flush mounting page 24
10 Selector switch actuator 3 positions page 18 | Selector switch actuator 3 positions, flush mounting page 24
11 Selector switch actuator 3 positions page 18 | Selector switch actuator 3 positions, flush mounting page 24
12 Selector switch actuator 3 positions page 18 | Selector switch actuator 3 positions, flush mounting page 24
Circuit drawing
(blue) a (red) b (yellow) c
61
Drawings
67
01.2009
13 Illuminated pushbutton actuator page 12
14 Keylock switch actuator 3 positions page 16 | Keylock switch act uator 3 positions, flush mounting page 22
15 Keylock switch actuator 3 positions page 16 | Keylock switch act uator 3 positions, flush mounting page 22
16 Keylock switch actuator 2 positions page 15 | Keylock switch act uator 2 positions, flush mounting page 21
17 Keylock switch actuator 2 positions page 15 | Keylock switch act uator 2 positions, flush mounting page 21
18 Keylock switch actuator 3 positions page 16 | Keylock switch act uator 3 positions, flush mounting page 22
19 Keylock switch actuator 3 positions page 16 | Keylock switch act uator 3 positions, flush mounting page 22
20 Diode element page 34
21 Diode element page 34
22 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
23 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
61
Drawings
68
01.2009
24 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Keylock- and Selector
switch 3 positions page 36
25 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
26 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
27 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
28 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
29 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
30 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Keylock- and Selector
switch 3 positions page 36
31 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
61
Drawings
69
01.2009
32 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
33 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Keylock- and Selector
switch 3 positions page 36
34 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Keylock- and Selector
switch 3 positions page 36
35 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35
36 Switching element for Pushbutton | Keylock- and Selector switch 2 positions page 35 | Switching element for Keylock- and Selector
switch 3 positions page 36 | Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36 | Switching element
for Stop pushbutton, foolproof page 37
37 Switching element for Keylock- and Selector switch 3 positions page 36 | Switching element for Emergen cy-stop pushbutton,
foolproof EN IEC 60947-5-5 page 36 | Switching element for Stop pushbutton, foolproof page 37
38 Switching element for Emergency-stop pushbutton, foolproof EN IEC 60947-5-5 page 36 | Switching element for Stop pushbutton,
foolproof page 37
Index from Typ-Nr.
70
01.2009
Typ-Nr. Page Typ-Nr. Page Typ-Nr. Page
01-907 ........................................41
02-905 ........................................41
02-912.1 .....................................39
02-912.2 .....................................39
02-912.3 .....................................39
02-912.4 .....................................39
10-1306.1349 .............................38
10-1307.1369 .............................38
10-1309.1309 .............................38
10-1310.1319 .............................38
10-1311.1249 .............................38
10-1312.1229 .............................38
10-1313.1209 .............................38
10-1313.1249 .............................38
10-1316.1179 .............................38
10-1316.1209 .............................38
10-1319.1179 .............................38
10-1319.1199 .............................38
10-2J06.3142 .............................39
10-2J06.3144 .............................39
10-2J06.3145 .............................39
10-2J06.3146 .............................39
10-2J06.3149 .............................39
10-2J09.1062 .............................39
10-2J09.1064 .............................39
10-2J09.1065 .............................39
10-2J09.1066 .............................39
10-2J09.1069 .............................39
10-2J12.1062 .............................39
10-2J12.1064 .............................39
10-2J12.1065 .............................39
10-2J12.1066 .............................39
10-2J12.1069 .............................39
10-2J13.1062 .............................39
10-2J13.1064 .............................39
10-2J13.1065 .............................39
10-2J13.1066 .............................39
10-2J13.1069 .............................39
10-2J19.1042 .............................39
10-2J19.1044 .............................39
10-2J19.1045 .............................39
10-2J19.1046 .............................39
10-2J19.1049 .............................39
14-987.1001 ...............................33
31-929 ........................................38
31-946 ........................................37
31-985.0 .....................................33
31-989.300 .................................33
31-989.311 .................................33
31-991 ........................................40
51-910 ........................................41
51-920 ........................................32
51-925 ........................................32
51-943.1 .....................................37
51-943.9 .....................................42
51-947.0 .....................................32
51-948.0 .....................................32
51-949.0 .....................................32
52-928.0 .....................................29
52-928.20 ...................................29
52-928.30 ...................................29
52-928.40 ...................................29
52-928.50 ...................................29
52-928.60 ...................................29
52-928.9 .....................................29
52-929.20 ...................................29
52-929.30 ...................................29
52-929.40 ...................................29
52-929.50 ...................................29
52-929.60 ...................................29
52-929.8 .....................................29
52-929.9 .....................................29
52-950.0 .....................................30
52-952.0 .....................................30
61-0000.02 .................................19
61-0009.0 ...................................19
61-0010.02 .................................11
61-0019.0 ...................................11
61-0020.02 .................................11
61-0029.0 ...................................11
61-0030.02 .................................11
61-0039.0 ...................................11
61-0040.02 .................................11
61-0049.0 ...................................11
61-0050.02 .................................11
61-0059.0 ...................................11
61-1100.0 ...................................20
61-1100.0 ...................................20
61-1110.0 ...................................12
61-1120.0 ...................................12
61-1130.0 ...................................12
61-1140.0 ...................................12
61-1140.0 ...................................14
61-1150.0 ...................................12
61-1200.0 ...................................20
61-1200.0 ...................................20
61-1210.0 ...................................12
61-1220.0 ...................................12
61-1230.0 ...................................12
61-1240.0 ...................................12
61-1240.0 ...................................14
61-1250.0 ...................................12
61-1300.0 ...................................20
61-1300.0 ...................................20
61-1310.0 ...................................12
61-1320.0 ...................................12
61-1330.0 ...................................12
61-1350.0 ...................................12
61-2101.0/D ............... .................15
61-2101.0/D ............... .................21
61-2201.0/D ............... .................15
61-2201.0/D ............... .................21
61-2203.0/D ............... .................15
61-2203.0/D ............... .................21
61-2205.0/D ............... .................15
61-2205.0/D ............... .................21
61-2501.0/D ............... .................16
61-2501.0/D ............... .................22
61-2601.0/D ............... .................16
61-2601.0/D ............... .................22
61-2602.0/D ............... .................16
61-2602.0/D ............... .................22
61-2603.0/D ............... .................16
61-2603.0/D ............... .................22
61-2604.0/D ............... .................16
61-2604.0/D ............... .................22
61-2605.0/D ....... ......................... 16
61-2605.0/D ....... ......................... 22
61-2606.0/D ....... ......................... 16
61-2606.0/D ....... ......................... 22
61-2607.0/D ....... ......................... 16
61-2607.0/D ....... ......................... 22
61-2701.0/D ....... ......................... 16
61-2701.0/D ....... ......................... 22
61-2703.0/D ....... ......................... 16
61-2703.0/D ....... ......................... 22
61-2705.0/D ....... ......................... 16
61-2705.0/D ....... ......................... 22
61-2801.0/D ....... ......................... 16
61-2801.0/D ....... ......................... 22
61-2802.0/D ....... ......................... 16
61-2802.0/D ....... ......................... 22
61-2804.0/D ....... ......................... 16
61-2804.0/D ....... ......................... 22
61-3440.4/1 ................................13
61-3440.4/1S ..............................13
61-3440.4/2 ................................13
61-3440.4/5 ................................13
61-3440.4/8 ................................14
61-3440.4/D ....... ......................... 13
61-4110.0 ...................................17
61-4110.0 ...................................23
61-4210.0 ...................................17
61-4210.0 ...................................23
61-4510.0 ...................................18
61-4510.0 ...................................24
61-4610.0 ...................................18
61-4610.0 ...................................24
61-4710.0 ...................................18
61-4710.0 ...................................24
61-4810.0 ...................................18
61-4810.0 ...................................24
61-4970.10 .................................24
61-4970.13 .................................24
61-5441.0/KA .............................14
61-5441.4/K ................................13
61-8000.05 .................................34
61-8006.01 .................................33
61-8006.02 .................................33
61-8101.02 .................................34
61-8102.02 .................................34
61-8212.12 .................................35
61-8212.22 .................................35
61-8410.12 .................................35
61-8410.22 .................................35
61-8420.12 .................................35
61-8420.22 .................................35
61-8430.12 .................................35
61-8430.22 .................................35
61-8440.12 .................................35
61-8440.22 .................................35
61-8450.12 .................................35
61-8450.22 .................................35
61-8460.12 .................................35
61-8460.22 .................................35
61-8470.12 .................................35
61-8470.22 .................................35
61-8480.12 .................................35
61-8480.22 .................................35
Index from Typ-Nr.
71
01.2009
Typ-Nr. Page Typ-Nr. Page Typ-Nr. Page
61-8490.12 .................................35
61-8490.22 .................................35
61-8520.12 .................................36
61-8520.22 .................................36
61-8550.12 .................................36
61-8550.22 .................................36
61-8574.12 .................................36
61-8574.22 .................................36
61-8610.11 .................................35
61-8610.17 .................................35
61-8610.37 .................................35
61-8615.11 .................................35
61-8620.17 .................................35
61-8620.37 .................................35
61-8625.11 .................................35
61-8640.11 .................................35
61-8640.17 .................................35
61-8640.37 .................................35
61-8645.11 .................................35
61-8650.17 .................................35
61-8650.37 .................................35
61-8655.11 .................................35
61-8670.17 .................................35
61-8670.37 .................................35
61-8675.11 .................................35
61-8720.17 .................................36
61-8720.37 .................................36
61-8725.11 .................................36
61-8745.11 .................................36
61-8745.17 .................................36
61-8745.37 .................................37
61-8750.17 .................................36
61-8750.37 .................................36
61-8755.11 .................................36
61-8755.11 .................................36
61-8755.17 .................................36
61-8755.37 .................................37
61-8770.17 .................................36
61-8770.37 .................................36
61-8775.11 .................................36
61-8775.11 .................................36
61-8775.17 .................................36
61-8775.37 .................................37
61-9028.0 ...................................29
61-9028.20 .................................29
61-9028.30 .................................29
61-9028.40 .................................29
61-9028.50 .................................29
61-9028.60 .................................29
61-9028.9 ...................................29
61-9029.20 .................................29
61-9029.30 .................................29
61-9029.40 .................................29
61-9029.50 .................................29
61-9029.60 .................................29
61-9029.8 ...................................29
61-9029.9 ...................................29
61-9210.0 ...................................28
61-9210.0 ...................................28
61-9211.0 ...................................25
61-9211.8 ...................................25
61-9211.9 ...................................25
61-9220.0 ...................................28
61-9220.0 ................................... 28
61-9221.0 ................................... 25
61-9221.8 ................................... 25
61-9221.9 ................................... 25
61-9226.0 ................................... 25
61-9226.8 ................................... 25
61-9226.9 ................................... 25
61-9230.0 ................................... 28
61-9230.0 ................................... 28
61-9231.0 ................................... 25
61-9231.8 ................................... 25
61-9231.9 ................................... 25
61-9236.0 ................................... 25
61-9236.8 ................................... 25
61-9236.9 ................................... 25
61-9250.0 ................................... 28
61-9251.0 ................................... 25
61-9251.8 ................................... 25
61-9251.9 ................................... 25
61-9311.1 ................................... 25
61-9311.2 ................................... 25
61-9311.3 ................................... 25
61-9311.4 ................................... 25
61-9311.5 ................................... 25
61-9311.6 ................................... 25
61-9311.7 ................................... 25
61-9321.1 ................................... 25
61-9321.2 ................................... 25
61-9321.3 ................................... 25
61-9321.4 ................................... 25
61-9321.5 ................................... 25
61-9321.6 ................................... 25
61-9321.7 ................................... 25
61-9326.2 ................................... 25
61-9326.3 ................................... 25
61-9326.4 ................................... 25
61-9326.5 ................................... 25
61-9326.6 ................................... 25
61-9326.7 ................................... 25
61-9331.1 ................................... 25
61-9331.2 ................................... 25
61-9331.3 ................................... 25
61-9331.4 ................................... 25
61-9331.5 ................................... 25
61-9331.6 ................................... 25
61-9331.7 ................................... 25
61-9336.2 ................................... 25
61-9336.3 ................................... 25
61-9336.4 ................................... 25
61-9336.5 ................................... 25
61-9336.6 ................................... 25
61-9336.7 ................................... 25
61-9351.1 ................................... 25
61-9351.2 ................................... 25
61-9351.3 ................................... 25
61-9351.4 ................................... 25
61-9351.5 ................................... 25
61-9351.6 ................................... 25
61-9351.7 ................................... 25
61-9450.0 ................................... 32
61-9451.0 ................................... 33
61-9452.0 ................................... 33
61-9453.0 ................................... 33
61-9480.5 ...................................40
61-9480.6 ...................................42
61-9481.6 ...................................40
61-9481.6 ...................................42
61-9593.0 ...................................28
61-9593.2 ...................................28
61-9593.4 ...................................28
61-9593.5 ...................................28
61-9600.0 ...................................31
61-9600.1 ...................................31
61-9642.1 ...................................25
61-9642.1 ...................................25
61-9642.2 ...................................25
61-9642.2 ...................................25
61-9642.3 ...................................25
61-9642.3 ...................................25
61-9642.4 ...................................25
61-9642.4 ...................................25
61-9642.5 ...................................25
61-9642.5 ...................................25
61-9642.6 ...................................25
61-9642.6 ...................................25
61-9642.7 ...................................25
61-9642.7 ...................................25
61-9643.201 ...............................26
61-9643.201 ...............................26
61-9643.202 ...............................26
61-9643.202 ...............................26
61-9643.203 ...............................26
61-9643.203 ...............................26
61-9643.301 ...............................26
61-9643.301 ...............................26
61-9643.401 ...............................26
61-9643.401 ...............................26
61-9643.501 ...............................26
61-9643.501 ...............................26
61-9643.502 ...............................26
61-9643.502 ...............................26
61-9643.503 ...............................26
61-9643.503 ...............................26
61-9643.601 ...............................26
61-9643.601 ...............................26
61-9643.602 ...............................26
61-9643.602 ...............................26
61-9643.603 ...............................26
61-9643.603 ...............................26
61-9643.701 ...............................26
61-9643.701 ...............................26
61-9643.702 ...............................26
61-9643.702 ...............................26
61-9643.703 ...............................26
61-9643.703 ...............................26
61-9671.1 ...................................25
61-9671.2 ...................................25
61-9671.3 ...................................25
61-9671.4 ...................................25
61-9671.5 ...................................25
61-9671.6 ...................................25
61-9671.7 ...................................25
61-9681.1 ...................................25
61-9681.2 ...................................25
61-9681.3 ...................................25
61-9681.4 ...................................25
Index from Typ-Nr.
72
01.2009
Typ-Nr. Page Typ-Nr. Page Typ-Nr. Page
61-9681.5 ...................................25
61-9681.6 ...................................25
61-9681.7 ...................................25
61-9707.7 ...................................26
61-9711.0 ...................................42
61-9730.0 ...................................41
61-9740.0 ...................................41
61-9771.0 ...................................25
61-9771.8 ...................................25
61-9771.9 ...................................25
61-9781.0 ...................................25
61-9781.8 ...................................25
61-9781.9 ...................................25
61-9820.1 ...................................37
61-9821.1 ...................................37
61-9823 ......................................37
61-9830 ......................................37
61-9830.2 ...................................38
61-9831.2 ...................................38
61-9841.0 ...................................27
61-9841.0 ...................................28
61-9841.0A ............ .....................27
61-9841.0A ............ .....................27
61-9841.2 ...................................27
61-9841.2 ...................................28
61-9841.2A ............ .....................27
61-9841.2A ............ .....................27
61-9841.4 ...................................27
61-9841.4 ...................................28
61-9841.4A ............ .....................27
61-9841.4A ............ .....................27
61-9841.5 ...................................27
61-9841.5 ...................................28
61-9841.5A ............ .....................27
61-9841.5A ............ .....................27
61-9841.6 ...................................27
61-9841.6 ...................................28
61-9841.6A ............ .....................27
61-9841.6A ............ .....................27
61-9841.8 ...................................27
61-9841.8 ...................................28
61-9841.8A ............ .....................27
61-9841.8A ............ .....................27
61-9842.0 ...................................27
61-9842.0 ...................................28
61-9842.2 ...................................27
61-9842.2 ...................................28
61-9842.4 ...................................27
61-9842.4 ...................................28
61-9842.5 ...................................27
61-9842.5 ...................................28
61-9842.6 ...................................27
61-9842.6 ...................................28
61-9842.8 ...................................27
61-9842.8 ...................................28
61-9912.0 ...................................41
61-9915.0 ...................................40
61-9920.0 ...................................32
61-9921.0 ...................................32
61-9922.0 ...................................32
61-9924.0 ...................................32
61-9927.2 ...................................31
61-9930.0 ...................................30
61-9930.0 ...................................31
61-9930.4 ...................................30
61-9930.4 ...................................31
61-9931.0 ...................................30
61-9931.0 ...................................31
61-9931.4 ...................................30
61-9931.4 ...................................31
61-9932.0 ...................................31
61-9932.0 ...................................31
61-9932.1 ...................................31
61-9932.1 ...................................31
61-9932.10 .................................31
61-9932.10 .................................31
61-9933.0 ...................................30
61-9933.0 ...................................30
61-9933.1 ...................................30
61-9933.1 ...................................30
61-9933.10 .................................30
61-9933.10 .................................30
61-9934.8 ...................................30
61-9936.0 ...................................31
61-9960 ......................................41
61-9965 ......................................40
61-9970.0 ...................................39
61-9970.1 ...................................39
61-9970.2 ...................................39
61-9970.3 ...................................39
61-9970.6 ...................................39
61-9980.0 ...................................29
704.945.6 ...................................40
704.945.6 ...................................42
704.968.0 ...................................30
704.968.1 ...................................30
84-9103.7 ...................................31
K61-999.100 ............................... 41
EAO AG
Tannwaldstrasse 88
4601 Olten, Switzerland
E-mail info@eao.com
Website www.eao.com
Austria
Phone +49 201 85 87 0
Fax +49 201 85 87 210
E-mail sales.ede@eao.com
Belgium
Phone +32 3 777 82 36
Fax +32 3 777 84 19
E-mail sales.ebl@eao.com
China
Phone +852 27 86 91 41
Fax +852 27 86 95 61
E-mail sales.ehk@eao.com
France
Phone +33 1 64 43 37 37
Fax +33 1 64 43 37 49
E-mail sales.ese@eao.com
Germany
Phone +49 201 85 87 0
Fax +49 201 85 87 210
E-mail sales.ede@eao.com
Italy
Phone +39 035 481 0189
Fax +39 035 481 3786
E-mail sales.eit@eao.com
Japan
Phone +81 3 5444 5411
Fax +81 3 5444 0345
E-mail sales.esj@eao.com
Netherlands
Phone +31 78 653 17 00
Fax +31 78 653 17 99
E-mail sales.enl@eao.com
Sweden
Phone +46 8 683 86 60
Fax +46 8 724 29 12
E-mail sales.esw@eao.com
Switzerland
Phone +41 62 388 95 00
Fax +41 62 388 95 55
E-mail sales.ech@eao.com
United Kingdom
Phone +44 1444 236 000
Fax +44 1444 236 641
E-mail sales.euk@eao.com
USA
Phone +1 203 877 4577
Fax +1 203 877 3694
E-mail sales.eus@eao.com
Other Countries
Phone +41 62 286 92 10
Fax +41 62 296 21 62
E-mail info@eao.com
EAO reserves the right to alter specifications without further notice