12/21/2016 Home 1VE10N | Omron Control Equipment Japan Contact Us solution Technical guide Product information Product Search Login / New registration Request catalog download support Full text search Search Seminar Sales network online store Home > Product Information > Product category > Switch > Limit switch > Generalpurpose horizontal form > VE > Format List > 1VE10N Japanese General-purpose enclosed switch 1VE10N View Cart (0) Open printing page Standard sensitivity, IP60, snap action, selfresetting mechanism, single pole double throw, 1c, seal plunger type Shape / structure Universal Horizontal Type Actuator Seal Plunger type Contact configuration 1c load General load Protective structure IEC 60529 standard (JEM standard): IP60 Generalpurpose enclosed switch VE catalog Format list of VE Image Rating / Specification Shape Series manual About this format Add to my parts add to cart Body mounting hole machining drawing Circuit configuration CAD Information update: 2016/08/30 Shape / structure Universal Horizontal Type lifespan General form Motion method Snap Action Actuator Seal Plunger type Rated frequency 50/60 Hz Switch mechanism Selfresetting mechanism Contact type Single pole double throw Contact configuration 1c load General load Switching ability (AC) / no inductive load Rated voltage: AC125V / resistive load: 10A (NC) 10A (NO ) / lamp load: 3A (NC) 2A (NO ) Rated voltage: AC250V / resistive load: 10A (NC) 10A (NO ) / lamp load: 2A ( NC) 1.5 A (NO) Rated voltage: AC125V / inductive load: 10A (NC) 10A (NO ) / motor load: Switching capacity (AC) / inductive load 3A (NC) 2A (NO ) Rated voltage: AC250V / inductive load: 10A (NC) 10A (NO ) / motor load: 2A ( NC) 1.5 A (NO) Rated voltage: DC8V / resistive load: 10A (NC) 10A (NO ) / lamp load: 6A (NC) 3A (NO ) Rated voltage: DC14V / resistive load: 10A (NC) 10A (NO ) / lamp load: 6A ( NC) 3A (NO) rated voltage: DC30V / resistive load: 6A (NC) 6A (NO ) / lamp load: 4A Switching ability (DC) / no inductive load Standard price (tax not included) 3,900 Special price (tax excluded) 3,694 Special price (tax included) 3,990 Delivery date classification Standard stock Selling price special price delivery date classification will be information at Omron FA store. Environmental and Safety Response Search RoHS / REACH compatibility status Export confirms the non judgment To inquire Selection, operation, setting method etc. (NC) 3A (NO ) rated voltage: DC125V / resistive load: 0.6A (NC) 0.6A ( NO) / lamp load: 0.1A (NC) 0.1A (NO ) rated voltage: DC250V / resistive load: 0.3A (NC) 0.3A (NO ) / lamp load: 0.05A (NC) 0.05A (NO ) Allowable inrush current Always closed (NC): 24A normally open (NO): 24A Ambient temperature range When used: 10 to 80 C Ambient humidity range When used: 35 to 95% Allowable operating speed 0.1 mm / s to 0.5 m / s http://www.fa.omron.co.jp/product/item/9852/ 1/3 12/21/2016 1VE10N | Omron Control Equipment Allowable operation 120 times / min or less frequency (mechanical) Allowable operation 60 times / minute or less frequency (electrical) 15m or less (initial value) (by the method of measuring the contact resistance meter) Contact resistance Between the same extreme child: 100M charging metal part and ground between: 100M Insulation resistance each terminal and the noncharging metal part between: 100M (at DC500V mega) Between the same extreme child: 1000V charging metal part and ground between: 1500V each terminal and the noncharging metal part between: 1500V Withstand voltage (50 / 60Hz 1 Min) More than 150 million times (at no load) Durability (mechanical) (temperature, humidity conditions: 5 35 , 40 % 70% RH) Durability (electrical) More than 30 million times (at AC125V 10A (resistive load)) (temperature, humidity conditions: 5 35 , 40 % 70% RH) Vibration proof (malfunction) Free state at continuous change of 10 to 55 Hz, multiple amplitude 1.5 mm, contact separation at operation limit position within 1 ms Impact resistance 1,000 m / s 2 (durability) Impact resistance Free state in a range of up to 300 m / s 2, within 1 ms of contact opening at (malfunction) operating limit position Protective structure IEC 60529 standard (JEM standard): IP60 Mounting specification Rear mounting Power required for operation (OF) Standard value Maximum 22.26 N Return force (RF) Standard value minimum 2.23 N Movement to action (PT) Standard value Maximum 2 mm Motion after movement (OT) Standard value minimum 6.3 mm Hysteresis movement (MD) Standard value maximum 0.8 mm Operating position (OP) Standard value 61.1 0.8 mm Information update: 2016/08/30 Back to the top of the page Notice Latest information Information on new products Product information Related information Sensor Format name index switch Selection by purpose / specification Safety Usage example collection relay Discontinued product / recommended substitute item Control Catalog / Manual correction FA system equipment Standard certification / compliance Motion / Drive RoHS / REACH compatible Robotics Usage notes Energy conservation support / environment countermeasure equipment Special page Power supply / peripheral equipment etc. solution Technical guide Download center Sysmac Style Product FAQ catalog http://www.fa.omron.co.jp/product/item/9852/ support Seminar Sales network 2/3 12/21/2016 Control panel (Panel Assist Web) 1VE10N | Omron Control Equipment Technical commentary manual Environmental diagnosis 2D CAD FA terminology dictionary Test machine loan 3D CAD Electrically controlled CAD Export Such non judgment Domestic sales network Select from the venue Overseas sales network Select from courses Rising support software Select from products Choose from work Preventive maintenance Product repair Site restoration engineering OMRON Corporation help site map Related Links Privacy Policy Terms of use Acceptance items of goods (c) Copyright OMRON Corporation 1996 2016. All Rights Reserved. http://www.fa.omron.co.jp/product/item/9852/ 3/3