POWER LPS50 Series 60 Watts Data Sheet Total Power: 55 - 60 Watts Input Voltage: 90 - 264 Vac 127 - 300 Vdc # of Outputs: Single SPECIAL FEATURES Universal input 2" x 4" footprint Less than 1U high Remote sense Overload and short circuit protection Adjustable output voltage High efficiency High MTBF Built in EMI filter (CISPR 22 Class B) LED power good indicator Input power < 74 watts Complies with EN61000-3-2 RoHS compliant UL Class I approved LPS52(-I) and LPS53(-I) extended temperature option: -40 C to +80 C LPX100 enclosure kit available Electrical Specifications Input SAFETY UL TUV CB CE Input range 90 - 264 Vac (wide range) 127 - 300 Vdc1 Frequency 47 - 63 / 440 Hz (Safety rating 50/60 Hz) Inrush current <60 A peak @ 230 Vac, cold start @ 25 C Input power <74 Watts Efficiency 80 - 85% typical at full load EMI/RFI FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted. Safety ground leakage current <0.5 mA @ 50/60 Hz; 264 Vac input for class I; <0.25 mA @ 50/60 Hz; 264 Vac input for class II Output UL 60950-1 CAN/CSA-C22.2 60950-1 EN60950-1 Certificate and report LVD & EMC 1 Maximum power 60 W for convection (LPS52 is 55 W) Adjustment range +20% minimum Hold-up time 10/20 ms 115/230 Vac input line Overload protection Short circuit protection on all outputs. Case overload protected @ 110-160% of normal rating Overvoltage protection 30% to 50% above nominal output Remote sense Compensates for 0.5 V lead drop max. Will operate without remote sense connected. Reverse connection protected. DC input rating is not part of the product's Safety approval. LPS50 Series Data Sheet Environmental Specifications Operating temperature 0 to 50 C ambient derate each output 2.5% per degree from 50 to 70 C. -20 C start up. For LPS52(-I) and LPS53(-I) -40 C to 80 C derate each output 2.5% per degree from 50 to 80 C Storage temperature -40 C to +85 C Electromagnetic susceptibility Designed to meet IEC61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11 Level 3 Humidity Operating; non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 MTBF demonstrated >550,000 hours at full load and 25 C ambient conditions Mechanical Drawings VR1 Output Voltage Adjust Pot M1 M2 C4 ~ R3 A DB1 ~ Q5 R3 VR1 C3 C32 TP1 C27 R1 D4 SK2 1 C30 F1 L1 C22 A C5 1 3 B SK1 T3.15A 2.5A 250VAC F2 C1 C18 Q6 R2 TH1 DIP C9 I J3 2 C17 2005 6 T2 E F J1 J2 G H R26 T3.15A 2.5A 250VAC 1 T1 L3 C2 2.00" [50.8] CN1 GND J4 L2 4 C2 D2 1.72" [43.8] + HTSK_SEC D J LED1 04272000202X-JA 3.73" [94.7] 4.00" [101.6] Mounting Hole O0.16"[4.0] 4 Places Max. Screw Head Diamater .22" (5.6) 0.16" [4.0] 0.197" (5.0) Minimum Standoff Height 1.30" [33.0] GRN/ YEL TP2 LPS50 Series Data Sheet Ordering Information LPS52 5V 0A Maximum Load with Convection Cooling 11 A 12 A 2% 50 mV LPS52(-I)4 5V 0A 11 A 12 A 2% 50 mV Model Number Output Voltage Minimum Load Peak Load1 Regulation2 Ripple P/P (PARD)3 LPS53 12 V 0A 5A 5.4 A 2% 120 mV LPS53(-I) 12 V 0A 5A 5.4 A 2% 120 mV LPS54 15 V 0A 4A 4.4 A 2% 150 mV LPS55 24 V 0A 2.5 A 2.75 A 2% 240 mV LPS58 48 V 0A 1.25 A 1.35 A 2% 480 mV 1. Peak current lasting <15 seconds with a maximum 10% duty cycle. 2. At 25 C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F (tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 4. LPS52(-I) is an extended temperature range model operating from -40 C to +80 C 5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Pin Assignments Connector LPS52 Mating Connectors LPS53 LPS54 LPS55 LPS58 SK1-1 Line Line Line Line Line SK1-3 Neutral Neutral Neutral Neutral Neutral SK2-1 +5 V +12 V +15 V +24 V +48 V SK2-2 +5 V +12 V +15 V +24 V +48 V SK2-3 Common Common Common Common Common SK2-4 Common Common Common Common Common SK2-5 -Sense -Sense -Sense -Sense -Sense SK2-6 +Sense +Sense +Sense +Sense +Sense AC Input Molex 09-50-8031 (USA) 09-93-0300 (UK) PINS: 08-52-0113 DC Outputs Molex 09-50-8061 (USA) 09-93-0600 (UK) PINS: 08-52-0113 Astec Connector Kit #70-841-006, includes all of the above 1. 2. 3. 4. 5. Specifications subject to change without notice. All dimensions in inches (mm), tolerance is 0.02"( 0.5 mm) Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 Vac input, 25 C unless otherwise stated. 6. Warranty: 2 years 7. Weight: 0.41lbs/0.18kg WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong +852 2176 3333 Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. Specifications are subject to change without notice. (c) 2017 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com LPS50 Series-DS 08Feb2017