The MBC40 Series of open-frame medical power supplies, with its wide universal 90-264 VAC input range, is available at 40 W of output power and a variety of single and multiple output voltages. The MBC series was designed to 3rd edition medical approvals and provides 2x MOPP (Means of Patient Protection) isolation for class 1 and class 2 installations. 40 W convection cooled 90-264 VAC input 20 to 50 deg C full load operation 2x MOPP 4 x 2 x 1.2" (101.6 mm x 50.8mm x 30.5 mm) No minimum load required - single output models No load power < 0.3 W IEC Protection Class Options: o Class I: Earthing Tab J4 (no suffix) o Class II: No Earthing Tab (-2 suffix) Conducted EMI EN 55022-B, FCC Part 15 Level B Medical Safety Agency Approvals RoHS Compliant CE marked These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices. Dialysis Monitoring Pumps Surgical Devices Home Health Portable Device North America +1-866.513.2839 Asia-Pacific +86.755.29885888 Europe, Middle East +353 61 225 977 Bel Power Solutions 152 North 3rd Street, Suite 805 San Jose, CA 95112 USA tech.support@psbel.com (c) 2014 Bel Power Solutions, inc. BCD.00286_AA MBC40 Series 1% TOTAL REGULATION 0.8% MBC40-1012G 12 3.5 0.0 1% 0.8% 130% Typical MBC40-1015G 15 2.7 0.0 1% 0.8% 130% Typical MBC40-1024G 24 1.7 0.0 1% 0.8% 130% Typical MBC40-1048G 48 0.83 0.0 1% 0.8% 130% Typical 5.2 6.0 0.5 1% 0.8% 130% Typical MBC40-3000G 12.5 2.0 0.1 1% 5.3% -12.8 0.5 0.0 1% 5.3% 5.2 6.0 0.5 1% 0.8% MODEL MBC40-1005G MBC40-3001G MBC40-3002G MBC40-3003G OUTPUT VOLTAGE OUTPUT CURRENT (VDC) 1 MAX (A) 5.1 8.0 MINIMUM LOAD (A) 3 0.0 RIPPLE & NOISE 2 23.8 1.0 0.1 1% 5.3% -12.8 0.5 0.0 1% 5.3% 5.2 6.0 0.5 1% 0.8% 14.6 1.5 0.1 1% 5.3% -14.8 0.5 0.0 1% 5.3% 3.3 6.0 1.0 1.5% 0.8% 5.2 3.0 0.1 1% 5.3% -12.8 0.5 0.0 1% 5.3% OVP THRESHOLD 130% Typical 130% Typical 130% Typical 130% Typical Warranty 2 years. NOTES: 1 2 3 Maximum outputs for each output. Max power rating should not be exceeded. Ripple and Noise may be 3% at initial start-up at -20 C. Output noise measurement is made with a 20 MHz bandwidth using a 6" twisted pair, terminated with a 10 uF tantalum capacitor in parallel with a 0.1 uF ceramic capacitor. Minimum load specified to meet cross regulation. 866.513.2839 tech.support@psbel.com (c) 2014 Bel Power Solutions, inc. BCD.00286_AA MBC40 Series Specifications are for nominal input voltage, 25C and max load unless otherwise stated. PARAMETER DESCRIPTION / CONDITION CRITERION Input Voltage Universal Input 90 - 264 VAC Input Frequency 4 47 to 400 Hz Input Surge Current 230 VAC (cold start) 60 A max. Safety Ground Leakage Current 230 VAC 120 VAC @ 40 W 230 VAC @ 40 W 250 A max Input Current 4 0.85 A 0.45 A Safety Approved: 47 to 63 Hz. PARAMETER DESCRIPTION / CONDITION CRITERION Voltage Adjustment V1 10% Efficiency >85% Hold Up Time 120 VAC input 6 ms Remote Sense V1 Main output 50 to 100% load change, 50/60 Hz, 50% duty cycle, 0.1A / uSec Over Voltage Protection V1: V2 & V3: Typical (V1 only) 0.5 VDC compensation < 10%, recovery time < 5 ms < 100 ms 3% 5% 130% Short Circuit Protection Typical 130% PARAMETER DESCRIPTION / CONDITION Input to Output: Input to Ground: Typical CRITERION 4242 VDC 2120 VDC 67 kHz MTBF according to MIL-HDBK-217F Full Load Derate linearly to 75% at 70 C >100 kh -20 to 50C 50 to 70C -40 to 70 C Transient Response Rise Time Set Point Tolerance Isolation Voltage Switching Frequency Reliability Operating Temperature Storage Temperature 866.513.2839 tech.support@psbel.com (c) 2014 Bel Power Solutions, inc. BCD.00286_AA MBC40 Series PARAMETER DESCRIPTION / CONDITION CRITERION Conducted Emissions EN55022, FCC part 15 Level B Harmonic Current Correction EN61000-3-2 Compliant Level 3 Electromagnetic Susceptibility EN61000-4-2 2, 3, 4, 5 Level 3 Conducted Immunity EN61000-4-6 Humidity Non Condensing Operating: Non-Operating: Altitude PARAMETER 95% 10,000 ft. 40,000 ft. DESCRIPTION/CONDITION Approved to the latest edition of the following standards: CSA/UL60601-1, EN60601-1 and IEC60601-1 Complies with LVD Directive Agency Approvals CE mark Figure 1 - Output Power Vs. Temperature CONNECTOR PIN AC Input Connector J1 DC Output Connector J2 Remote Sense J3 Earthing Tab J4 DESCRIPTION/CONDITION Pin 1 AC Neutral Pin 2 AC Line Pin 1,2 V1 Pin 3,4 RTN Pin 5 V3 Pin 6 V2 Pin 1 +V1 Sense Pin 2 -V1 Sense MANUFACTURER / PN Mating Connector: Molex: 09-50-3031 Pins: 08-50-0106 Mating Connector: Tyco: 647402-6 Pins: 3-647409-1 Mating Connector: Molex: 22-01-2021 Molex: 19705-4301 Mating Connector: Molex: 190030001 866.513.2839 tech.support@psbel.com (c) 2014 Bel Power Solutions, inc. BCD.00286_AA MBC40 Series PARAMETER DESCRIPTION/CONDITION Weight 150 g (0.33 lbs.) Dimensions 101.6 x 50.8 x 30.48 mm (4 x 2 x 1.2 inch) Figure 2 - Mechanical Drawing (Top and Side View) NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 866.513.2839 tech.support@psbel.com (c) 2014 Bel Power Solutions, inc. BCD.00286_AA