A
ZWX180/L1
SPECIFICATIONS(1/2)
A234-01-01/L1-
A
( This specifications sheet also apply to other option model /L2.)
MODEL ZWX180/L1
ITEMS V1 V2 V3 V4 V5 (5V SB)
1 Nominal Output Voltage V +3.3 +5 +12 -12 +5
2 Minimum Output Current A 0 0 0 0 0
3 Maximum Output Current (Convection) A 6.0 5.0 6.0 0.2 1.4
4 Maximum Output Power Each CH W19.8 25.0
(Convection) Combined 32W
5 Total Output Power (Convection) W 90
6 Maximum Output Current (Forced Air) A 8.4 7.0 9.0 0.3 2.0
7 Maximum Output Power Each CH W27.7 35.0
(Forced Air) Combined 54W
8 Total Output Power (Forced Air) W 153
9 Peak Output Current (*1) A 12.0 10.0 13.0 0.3 2.0
10 Peak Output Power Each CH (*1) W39.6 50.0
Combined 63W
11 Total Peak Output Power (*1) W 180
12 Efficiency (100/200VAC )(Typ) (*2) - 81%/84%
13 Input Voltage Range (*4) - 85-265VAC (47-63Hz)
14 Input Current (100/200VAC) (Typ) (*2) - 1.9A/1.0A
15 Inrush Current (100/200VAC) (Typ) (*5) - 14A/28A at Cold Start (Ta=25)
16 PFHC - Designed to meet IEC61000-3-2
17 Power Factor (100/200VAC )(Typ) (*2) - 0.99/0.93
18 Output Voltage Accuracy % ±5 ±5 ±5 ±5 ±5
19 Output Voltage Range - Fixed Fixed Fixed Fixed Fixed
20 Maximum Ripple & Noise -10<Ta<0°C mV 160 180 180 160 160
(*3,*6) 0<Ta<50°C mV 120 150 150 120 120
21 Maximum Line Regulation (*3,*6,*7) mV 20 48 48 20 20
22 Maximum Load Regulation (*3,*6,*8) mV 100 300 300 100 100
23 Over Current Protection (*9) A 8.82- 7.35- 9.45- 0.32- 2.1-
24 Over Voltage Protection (*10) -V1 : 114%-130%(3.76-4.3V), V2 : 115%-140%(5.74-7V)
V3 : 112%-130%(13.4-15.6V)
25 Hold-up Time (Typ) (*2) - 20ms at 100VAC
26 Leakage Current (*3,*11) -Less than 0.75mA
27 Remote Sensing Possible (V1 only)
28 ON/OFF Control (PS_ON) TTL compatible (H : Output Inhibit, L : Output Enable)
: Designed to meet ATX standard.
29 Series / Parallel Operation - -
30 Operating Temperature (*12) - -10 - +50°C : 100%, 60°C : 60%, 70°C : 20%
31 Operating Humidity - 30 - 90%RH (No Dewdrop)
32 Storage Temperature - -30 - +85°C
33 Storage Humidity - 10 - 95%RH (No Dewdrop)
34 Cooling (*12) - Convection Cooling / Forced air Cooling (System air Cooling) : 0.85 m
3/min
35 Withstand Voltage -Input-FG : 2kVAC(20mA), Input-Output : 3kVAC(20mA)
Output-FG : 500VAC(100mA) for 1min.
36 Isolation Resistance - More than 100M at 25°C and 70%RH Output-FG : 500VDC
37 Vibration - At no operating 10 - 55Hz(Sweep for 1min)
- 19.6 m/s2 Constant, X,Y,Z 1hour each.
38 Shock - Less than 392 m/s2 at no operating.
39 Safety - Approved by UL60950-1, CSA60950-1, EN60950-1, EN50178(OV II),
Designed to meet DENAN (Section 2) at 100VAC only.
40 Conducted Emission (*3) -Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B
41 Radiated Emission (*3) -Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B
3.6
7.0
10.0
-
156.0
108.0
72.0
3.6 10.0
2.4
DENSEI-LAMBD
A
ZWX180/L1
SPECIFICATIONS(2/2)
A234-01-02/L1
( This specifications sheet also apply to other option model /L2.)
MODEL ZWX180/L1
ITEMS V1 V2 V3 V4 V5 (5V SB)
42 Immunity - Desi
g
ned to meet IEC61000-4-2, -3, -4, -5, -6, -8, -11
43 Weight (Typ.) g 700
44 Size (W x H x D) mm 98 x 45.5 x 240 ( Refer to Outline Drawing )
*Read instruction manual carefully, before using the power supply unit.
=NOTE=
*1. Operating time at peak output is less than 5sec.
(Average output power and current are less than Maximum output power and current.)
*2. At total output power (Forced air) (V1=6.5A, V2=6.5A, V3=7.7A, V4=0.2A, V5=1.0A), Ta=25°C.
*3. At total output power (Forced air).
*4. For cases where conformance to various safety specs (UL, CSA, EN) are required,
to be described as 100 - 240VAC (50/60Hz).
*5. Not applicable for the inrush current to Noise Filter for less than 0.2ms.
*6. Please refer to Fig. A for measurement of line & load regulation and ripple voltage.
*7. 85 - 265VAC , constant load.
*8. No load-Full load, constant input voltage.
*9. Avoid to operate at overload or short circuit condition for more than 30 seconds.
V1,V2 and V3
: OCP circuit will shut down output except V5 with delay (more than 5s), manual reset (PS_ON reset or re power on.).
V4 : Constant current limit with automatic recovery.
V5 : Constant current limit in conjunction with all output with automatic recovery.
*10. OVP circuit will shut down output, manual reset (PS_ON reset or re power on.).
*11. Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25°C.
*12. At forced air cooling, standard mounting. Refer to output derating curve.(A234-01-03_, A234-01-04_)
Measure with EIAJ RC-9131 probe.
Bandwidth of scope : 100MHz
Capacitance
C1,C2,C3,C4,C5 : Film Cap. 0.1 µF
C6,C7,C8,C9,C10 : Elec. Cap. 100 µF
Fig.A
LOAD1
A
C1
3.3V sense
V1
COM
P.S.
150mm
AWG18
C6
LOAD2C2
V2
COM
C7
A
LOAD3C3
V3
COM
C8
A
LOAD4C4
V4
COM
C9
A
LOAD5C5
V5
COM
C10
A
PS_ON
COM
Meas uring Point
for Rippl e & Nois e.
Measuring Point for
V o and Line/Load R egulation.