I-6
Noise
Filter
EAP series
Small,High-voltage pulses common mode noise filters (1-Stage filter)
EAP -10 -472 -O
Ordering information
*
The dimensions change when the option is set.
Refer to External view.
1 2 3 4
Features of EAP series
Circuit Diagram Derating Curve
LINE
Case
: Mounting Plate
1
24
3
CY
CY
CY : Line to ground capacitor
LOAD
Small,High-voltage pulses common mode noise filters(1-Stage filter)
- Single Phase 250 VAC -Small-size
-Quick and easy push-down terminal
Just connect the wires,push-down and tighten
the screws with a screwdriver
Ambient Temperature [C]
Load Factor [%]
9050 60 70 80
20
0
-40 40-30 -20
100
80
60
40
55
Specifications
No. Items EAP-03-472 EAP-06-472 EAP-10-472 EAP-16-472 EAP-20-472 EAP-30-472
1 Rated Voltage[V] AC 1f 250 / DC250
2 Rated Current[A] 3 6 10162030
3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 500MW min at room temperature and humidity
5 Leakage current 125/250V 60Hz 0.5mA/1.0mA max
6 DC registance 180mW max 110mW max 40mW max 20mW max 10mW max 6mW max
7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve)
8 Operating temperature -40 to +85C (Refer to Derating Curve)
9 Operating humidity 20 to 95%RH (Non condensing)
10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing)
11 Vibration 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact 196.1m/s2 (20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
14 Case size (without projection) /Mass 39X30X85 mm (WXHXD) /170g max (Option : -D refer to external view)
DIN rail installation type is optionThe terminal cover is retracted inside the unit
1Model Name
2Rated Current
3Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code Leakage Current
(Input 125/250V 60Hz)
Line to ground
capacitor
(nominal value)
000 5 A/ 10 A max Not Provided
101 12.5 A/ 25 A max 100pF
221 25 A/ 50 A max 220pF
331 37.5 A/ 75 A max 330pF
471 50 A/ 100 A max 470pF
681 75.5 A/ 150 A max 680pF
102 0.13 mA/ 0.25mA max 1000pF
222 0.25 mA/ 0.5 mA max 2200pF
332 0.38 mA/ 0.75mA max 3300pF
472 0.5 mA/ 1.0 mA max 4700pF
* When the line to ground capacitor code is
different, the attenuation characteristic is
different.
4Options
D :DIN rail installation type
OG PQKUGHKNVGT'#KPFF +