ECS288 6/2016 9
The End-of-Life indicator helps the end user to receive a signal from the fixture indicating that it has reached its
programmed life-tim e. Af ter the LE D dr i ver r eaches t he pr ogrammed life-time, whenev er it is t urned ON, it sta ys at
‘Dim’ level (10%) for 10 minutes and reaches its appropriate level.
INRUSH CHARACTERISTICS
120 1.25 55µs
277 2.53 43µs
Complies to NEMA 410 inrush current requirements
DIMMER/SENSOR COMPATIBILITY
ZBHA-CLM DIM (NAED: 45678)
Encelium EMS
EN-LCM-1R10V-GB2-BK/DR
EN-ALC-1R10V-GB2-BK
Synergy lighting Controls
SU-3E-00 (Enlighted Compact Sensor)
Note 5: The absence of a dimmer from this chart does not necessarily imply incompatibility. Please reference the
dimmer manufacturer’s instructions for installation.
UL CONDITIONS OF ACCEPTABILITY (E320395)
Conditions of Acceptability – When installed in the end-product, consideration shall be given to the following:
• The LED driver was evaluated using an electronic LED load resulting in an output rated current and rated pow er
as indicated in the electrical ratings.
• The unit em ploys a Clas s B is olat ion trans former (T1) on th e m ain PW B. T he need to repe at th e Tem per ature
Test shall be determined in end-use product. Tc point case temperatures in the end-use shall not exceed 90⁰C.
• The unit was tested on a 20A branch circuit. If used on a branch circuit greater than this, additional testing may
be necessary.
• The PWB spacing for use in Damp locations have been evaluated to UL 8750. The unit is completely potted on
the bottom and partially potted on the top. Areas t hat are potted m eet spacing requirements are out of T able
7.4 Parts Potted or subsequently coated. Other areas meet applicable requirements in Table 7.4.
• The Leakage current test was conducted between the ground terminal, exposed conductive surface and the
grounded pole of the supply circuit.
• These products are intended for use in Dry and Damp locations. The use in other environmental locations shall
be considered in the end product.