The BXB75 Series are high power density dc-dc converters
packaged in the industry standard footprint (2.40 x 2.28 x 0.50
inches) to give designers optimum choices when specifying for
both new and replacement designs. Suitable for a wide range of
applications in nearly any industry, the BXB75 was particularly
designed with communication and distributed power applications
in mind. Using Bellcore 332, the MTBF is greater than 1,400,000
hours. Aluminum baseplate technology with four threaded M3
inserts makes heatsink attachment and optimum thermal
management easy. The BXB75 series is approved to IEC950 by UL,
CSA and VDE.
Embedded Power for
Business-Critical Continuity
BXB75 Series
Single output
Special Features
Industry standard footprint
MTBF >1.4 million hours
(Bellcore 332)
Input voltage to ETS300-132-2
Adjustable output voltage
No minimum load required
Separate case ground pin
2:1 input range for battery
powered applications
Undervoltage lockout (UVLO)
UL, VDE and CSA safety
approvals
Available RoHS compliant
2 year warranty
Total Power: 50 - 75W
Input Voltage: 36 - 75VDC
# of Outputs: Single
Safety
VDE0805/EN60950/IEC950
File No. 10401-3336-0205
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
Rev.03.08.07
bxb75s
1 of 4
Rev.03.08.07
bxb75s
2 of 4
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated.
Specifications
OUTPUT SPECIFICATIONS
Voltage adjustability 60% to 110%
Set point accuracy ±1.0%
Line regulation Low line to high line ±0.05%
Load regulation Full load to min. load ±0.10%
Minimum load 0%
Overshoot At turn-on and turn-off None
Undershoot None
Ripple and noise 3.3 V and 5 V 75 mV pk-pk,
(5 Hz to 20 MHz) 20 mV rms
(See Note 1) 12 V 100 mV pk-pk,
30 mV rms
Temperature coefficient ±0.01%/°C
Transient response ±2.0% max. deviation
(See Note 2) 170 μs recovery
to within ±1.0%
Remote sense 0.5 Vdc transmission
line drop compensation
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 36-75 Vdc
Input current No load 100 mA max.
Remote OFF 20 mA max.
Input current (max.) 3.5 A max. @ Io max.
(See Note 4) and Vin = 0-75 V
Input reflected ripple (See Note 6) 5 mA pk-pk
Active low remote ON/OFF (See Note 7)
Logic compatibility Open collector ref to -input
ON 1.2 Vdc max.
OFF Open circuit
INPUT SPECIFICATIONS (continued)
Undervoltage lockout 48 Vin: power up 34 V
48 Vin: power down 32.5 V
Start-up time Power up 20 ms
(See Note 8) Remote ON/OFF 20 ms
EMC CHARACTERISTICS
Conducted emissions Bellcore 1089 Level A
(See Note 3) FCC part 15 Level A
EN55022, CISPR22 Level A
GENERAL SPECIFICATIONS
Efficiency See table
Isolation voltage Input/case 1500 Vdc
Input/output 1500 Vdc
Output/case 1500 Vdc
Switching frequency Fixed 500 kHz typ.
Approvals and VDE0805, EN60950, IEC950
standards (See Note 5) UL1950, CSA C22.2 No. 950
Case material Aluminum baseplate
with plastic case
Material flammability UL94V-0
Weight 110 g (3.88 oz)
MTBF Bellcore 332 1,400,000 hours min.
MIL-HDBK-217F 580,000 hours min.
@ 40 °C, 100% full load
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating case temp. -40 °C to +100 °C
Non-operating -55 °C to +125 °C
Altitude Operating 10,000 feet max.
Non-operating 40,000 feet max.
Vibration 5-500 Hz 2.4 G rms (approx.)
Rev.03.08.07
bxb75s
3 of 4
Embedded Power for
Business-Critical Continuity
Specifications Contd.
Notes
1Measured with 10 μF tantalum capacitor and 1 μF ceramic capacitor across
output.
2di/dt = 0.1 A/1 μs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to 0.75 lo
max. and 0.75 lo max. to 0.5 lo max.
3Units should be characterised within systems. External components required.
4Input fusing is recommended based on surge current and maximum input
current.
5This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6Simulated source impedance of 12 μH. 12 μH inductor in series with +Vin.
7Active high remote on/off option is available (standard product is active low),
designate with the suffix ‘FHT’ e.g. BXB75-48S05FHTJ. Consult factory for
further details and options.
8Start-up into resistive load.
9The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
10 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
PROTECTION
Short circuit Continuous, automatic recovery
Overvoltage Non-latching
Undervoltage Non-latching
Thermal 110 °C baseplate,
automatic recovery
TELECOM SPECIFICATION
Central office interface A ETS300-132-2
OUTPUT INPUT OVP OUTPUT OUTPUT OUTPUT EFFICIENCY REGULATION MODEL
POWER VOLTAGE VOLTAGE CURRENT CURRENT (TYP.) LINE LOAD NUMBER (7, 9,10)
(MAX.) (MIN.) (MAX.)
50 W 36-75 Vdc 4.3 Vdc 3.3 V 0 A 15 A 79% ±0.05% ±0.1% BXB75-48S3V3FLTJ
75 W 36-75 Vdc 6.5 Vdc 5 V 0 A 15 A 83% ±0.05% ±0.1% BXB75-48S05FLTJ
75 W 36-75 Vdc 14.5 Vdc 12 V 0 A 6.25 A 84% ±0.05% ±0.1% BXB75-48S12FLTJ
EXTERNAL OUTPUT TRIMMING
Output can be externally
trimmed by using the
method shown.
TRIM
UP
TRIM
DOWN
8
7
6
RT1
OR
RT2
PIN CONNECTIONS
PIN
NUMBER FUNCTION
1+ Vin
2 Remote ON/OFF
3Case
4- Vin
5 - Vout
6 - Sense
7Trim
8 + Sense
9 + Vout
Embedded Power for
Business-Critical Continuity
Rev.03.08.07
bxb75s
4 of 4
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
ALL DIMENSIONS IN INCHES (mm)
Tolerance : x.xx ±0.02in. (0.51mm)
x.xxx ±0.010in. (0.254mm)
VIEW SHOWN
PIN SIDE UP
1.90
(48.26) 0.190 (4.83) ± 0.010 (0.25)
2 x Ø.080 (2.03) ± 0.002 (0.05)
4 x M3 x 0.5 Through
7 x Ø.040 (1.02) ±0.002 (0.05)
2.28 (57.91) Max.
0.700 (17.77)
1.000 (25.40)
1.400 (35.56)
2.000 (50.80)
0.190 (4.83) ±0.010 (0.25)
0.400 (10.16)
0.500 (12.69) ± 0.010 (0.25)
0.400 (10.16)
1.000 (25.40)
1.400 (35.56)
Vo(+) +SEN TRIM -SEN Vo (-)
VI(+) ON/OFF CASE VI (-)
0.200 (5.08) Min.
Length for all Input
and Output Pins
0.500 (12.70)
2.40 (60.96)
Max.