Including discontinued products ( ) HP 10 AMP POWER RELAY HP RELAYS TYPICAL APPLICATIONS Compliance with RoHS Directive FEATURES 1. High-capacity and long life Mechanical life is more than 10 million operations and, with electrical life of more than 200,000 operations (resistive load 10 A; inductive load 7.5 A), the relay has excellent inductive load durability. 2. Easy mounting and wiring The terminal arrangement is apparent at a glance and wiring is easy. Moreover, quick tab terminal is also possible. 3. Operation indicator option Optional operation indicators are available for easy visual confirmation that relays are operating. They simplify maintenance. 4. UL/CSA approved 5. Wide range of sockets and terminal sockets To enable use with DIN rails, DIN terminal sockets are also available. HP relays enjoy wide use in various applications, particularly in automation controls and remote controls. Applications include: 1. Industrial machinery For controlling positioning, pressure, and temperature in molding equipment, boilers, pumps, charging pressure equipment, measuring and evaluation equipment, textile machines, etc. 2. Machine tools Control of positioning and directional change in turning machines, lathes, borers, etc. 3. Food processing packing machines Automatic control of packing equipment for milk and seafood, bottling, canning, and packaging 4. Office equipment Control of copiers, time recorders, etc. 5. Coin operate machines Control of food, cigarette, and other vending machines 6. Measuring devices and equipment For repeating installation of control signals and in power amplifiers 7. Generators, transformers and power receiving equipment. Functional parts in protective equipment, functional assistance in automatic adjustment equipment, telemeters and other remote monitoring equipment 8. Control of conveyance equipment Control panels for elevators, escalators, and other conveyance equipment, control of all kinds industrial transport equipment such as conveyors. 9. Amusement equipment Control of equipment in amusement parks, etc., control of bowling alley equipment, control of fountains in public parks About Cd-free contacts We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix "F" should be added to the part number. The Suffix "F" is required only for 4 Form C contact type. The 2 Form C and 3 Form C contact type is originally cadmium-free, the suffix "F" is not required.) Please replace parts containing Cadmium with Cadmium-free products and evaluate them with your actual application before use because the life of a relay depends on the contact material and load. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Including discontinued products ( HP ORDERING INFORMATION HP Contact arrangement 2: 2 Form C 3: 3 Form C 4: 4 Form C Terminal arrangement Nil: Standard plug-in terminal TM: TM type (2 Form C only) M: Direct mounting (3 Form C only) Operation indication Nil: Without indication L: With indication Coil voltage AC 6, 12, 24, 48, 100, (115), 200, (220), (240) V DC 6, 12, 24, 48, 100, (110) V Contact material F: 4 Form C, Silver alloy (cadmium-free) Nil: 2 Form C, 3 Form C (Silver) With LED indicator type Coil voltage: 6, 12, 24 V AC 6, 12, 24, 48 V DC With neon lamp type Coil voltage: 100, 115, 200, 220, 240 V AC 100, 110 V DC TYPES 1. Plug-in type Coil voltage 6V AC 12V AC 24V AC 48V AC 100V AC 115V AC 200V AC 220V AC 240V AC 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 2 Form C Part No. HP2-AC6V HP2-AC12V HP2-AC24V HP2-AC48V HP2-AC100V HP2-AC115V HP2-AC200V HP2-AC220V HP2-AC240V HP2-DC6V HP2-DC12V HP2-DC24V HP2-DC48V HP2-DC100V HP2-DC110V 3 Form C Part No. HP3-AC6V HP3-AC12V HP3-AC24V HP3-AC48V HP3-AC100V HP3-AC115V HP3-AC200V HP3-AC220V HP3-AC240V HP3-DC6V HP3-DC12V HP3-DC24V HP3-DC48V HP3-DC100V HP3-DC110V Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs. Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. 4 Form C Part No. HP4-AC6V-F HP4-AC12V-F HP4-AC24V-F HP4-AC48V-F HP4-AC100V-F HP4-AC115V-F HP4-AC200V-F HP4-AC220V-F HP4-AC240V-F HP4-DC6V-F HP4-DC12V-F HP4-DC24V-F HP4-DC48V-F HP4-DC100V-F HP4-DC110V-F ) Including discontinued products ( ) HP 2. Plug-in type (with LED indication) Coil voltage With LED indication With neon lamp With LED indication With neon lamp 6V AC 12V AC 24V AC 100V AC 115V AC 200V AC 220V AC 240V AC 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 2 Form C Part No. HP2-L-AC6V HP2-L-AC12V HP2-L-AC24V HP2-L-AC100V HP2-L-AC115V HP2-L-AC200V HP2-L-AC220V HP2-L-AC240V HP2-L-DC6V HP2-L-DC12V HP2-L-DC24V HP2-L-DC48V HP2-L-DC100V HP2-L-DC110V 3 Form C Part No. HP3-L-AC6V HP3-L-AC12V HP3-L-AC24V HP3-L-AC100V HP3-L-AC115V HP3-L-AC200V HP3-L-AC220V HP3-L-AC240V HP3-L-DC6V HP3-L-DC12V HP3-L-DC24V HP3-L-DC48V HP3-L-DC100V HP3-L-DC110V 4 Form C Part No. HP4-L-AC6V-F HP4-L-AC12V-F HP4-L-AC24V-F HP4-L-AC100V-F HP4-L-AC115V-F HP4-L-AC200V-F HP4-L-AC220V-F HP4-L-AC240V-F HP4-L-DC6V-F HP4-L-DC12V-F HP4-L-DC24V-F HP4-L-DC48V-F HP4-L-DC100V-F HP4-L-DC110V-F Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs. Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs. 3. TM type and Direct mount type 2 Form C (TM type) Part No. HP2-TM-AC6V HP2-TM-AC12V HP2-TM-AC24V HP2-TM-AC48V HP2-TM-AC100V HP2-TM-AC115V HP2-TM-AC200V HP2-TM-AC220V HP2-TM-AC240V HP2-TM-DC6V HP2-TM-DC12V HP2-TM-DC24V HP2-TM-DC48V HP2-TM-DC100V HP2-TM-DC110V Coil voltage 6V AC 12V AC 24V AC 48V AC 100V AC 115V AC 200V AC 220V AC 240V AC 6V DC 12V DC 24V DC 48V DC 100V DC 110V DC 3 Form C (direct mount type) Part No. HP3-M-AC6V HP3-M-AC12V HP3-M-AC24V HP3-M-AC48V HP3-M-AC100V HP3-M-AC115V HP3-M-AC200V HP3-M-AC220V HP3-M-AC240V HP3-M-DC6V HP3-M-DC12V HP3-M-DC24V HP3-M-DC48V HP3-M-DC100V HP3-M-DC110V Standard packing: Carton: 10 pcs.; Case: 50 pcs. 4. Direct mount type (with LED indication) Coil voltage With neon lamp 100V AC 115V AC 200V AC 220V AC 240V AC 100V DC 110V DC 3 Form C Part No. HP3-ML-AC100V HP3-ML-AC115V HP3-ML-AC200V HP3-ML-AC220V HP3-ML-AC240V HP3-ML-DC100V HP3-ML-DC110V Standard packing: Carton: 10 pcs.; Case: 50 pcs. Notes: 1. Standard packaging is handled in units of inner cartons. Please specify if you require inner cartons to be boxed. 2. Sockets, terminal sockets and installation brackets are not included. Please order these separately. 3. For products compliant with international standards, please refer to the standards chart. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Including discontinued products ( HP ) RATING 1. Coil data 1) AC coils Contact arrangement 2 Form C 3 Form C 4 Form C Nominal coil voltage Nominal coil current (mA) Nominal operating power (VA) Inductance (H) 6V AC 50Hz 349mA 60Hz 310mA 50Hz 2.09VA 60Hz 1.9VA 50Hz 0.051 60Hz 0.049 12V AC 24V AC 48V AC 100V AC 115V AC 200V AC 220V AC 240V AC 6V AC 181.2mA 94mA 46.5mA 25.3mA 23.1mA 12.4mA 10.6mA 10.0mA 594mA 160mA 78mA 39mA 21mA 18mA 11mA 9.5mA 9.0mA 520mA 2.17VA 2.25VA 2.23VA 2.36VA 2.31VA 2.48VA 2.34VA 2.40VA 3.56VA 1.9VA 1.9VA 1.9VA 2.1VA 2.1VA 2.2VA 2.1VA 2.2VA 3.1VA 0.198 0.753 3.055 12.60 16.70 48.03 61.28 69.00 0.03 0.190 0.776 3.106 12.03 15.83 45.81 57.90 66.26 0.030 12V AC 24V AC 48V AC 100V AC 115V AC 200V AC 220V AC 240V AC 6V AC 297mA 148.7mA 74.2mA 36.4mA 32.5mA 18.2mA 16.0mA 15.8mA 909mA 260mA 130mA 65mA 32mA 28.5mA 16mA 14.2mA 13.9mA 800mA 3.56VA 3.56VA 3.56VA 3.64VA 3.74VA 3.65VA 3.54VA 3.79VA 5.46VA 3.1VA 3.1VA 3.1VA 3.2VA 3.3VA 3.2VA 3.1VA 3.3VA 4.8VA 0.123 0.0494 1.976 8.500 10.79 33.53 41.35 45.94 0.020 0.119 0.475 1.899 8.038 10.36 32.10 39.32 44.05 0.019 12V AC 24V AC 48V AC 100V AC 115V AC 200V AC 220V AC 240V AC 456mA 229mA 108mA 57.3mA 47.6mA 28.5mA 23.8mA 23.3mA 400mA 200mA 95mA 50mA 42mA 25mA 21mA 20.5mA 5.47VA 5.49VA 5.18VA 5.73VA 5.47VA 5.69VA 5.24VA 5.58VA 4.8VA 4.8VA 4.6VA 5.0VA 4.8VA 5.0VA 4.6VA 4.9VA 0.080 0.320 1.348 5.348 7.264 21.27 27.75 30.98 0.077 0.309 1.292 5.156 6.953 20.45 26.57 29.75 Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) Max. allowable voltage (at 20C 68F) 80%V or less of nominal voltage (Initial) 30%V or more of nominal voltage (Initial) 110%V of nominal voltage 80%V or less of nominal voltage (Initial) 30%V or more of nominal voltage (Initial) 110%V of nominal voltage 80%V or less of nominal voltage (Initial) 30%V or more of nominal voltage (Initial) 110%V of nominal voltage Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) Max. allowable voltage (at 20C 68F) 80%V or less of nominal voltage (Initial) 15%V or more of nominal voltage (Initial) 110%V of nominal voltage 80%V or less of nominal voltage (Initial) 15%V or more of nominal voltage (Initial) 110%V of nominal voltage 80%V or less of nominal voltage (Initial) 15%V or more of nominal voltage (Initial) 110%V of nominal voltage 2) DC coils (20C 68F) Contact arrangement 2 Form C 3 Form C 4 Form C Nominal coil voltage Nominal coil current (mA) Nominal operating power (W) Coil resistance () 6V DC 240mA 1.5W 25 12V DC 24V DC 48V DC 100V DC 110V DC 6V DC 109mA 54.5mA 26.7mA 14.9mA 15.0mA 250mA 1.3W 1.3W 1.3W 1.5W 1.7W 1.5W 110 440 1,800 6,700 7,300 24 12V DC 24V DC 48V DC 100V DC 110V DC 6V DC 120mA 60mA 31mA 15.6mA 14.9mA 273mA 1.4W 1.4W 1.5W 1.6W 1.6W 1.6W 100 400 1,560 6,400 7,450 22 12V DC 24V DC 48V DC 100V DC 110V DC 127mA 63mA 32.0mA 16.3mA 15.7mA 1.5W 1.5W 1.5W 1.6W 1.7W 95 380 1,500 5,950 7,000 Notes: 1. The rated current area is 15% (60Hz) [AC coils],. 10% (20C) [DC coils] 2. The coil resistance for DC operation is the value measured when the coil temperature is 20C 68F. Compensate 0.4% for every 1C change in temperature. 3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow leading possibly to coil burnout. 4. For use with 200 V DC, connect a 6.7k (10W) resistor, in series, to the 100 V DC relay [3 Form C type is .6.4k (5W); 4 Form C type is .6.2k (10W)]. 5. As a general rule, only a pure DC voltage should be used for the coil drive. However, a DC power supply that contains ripples has characteristics that differ from pure DC. Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Including discontinued products ( ) HP 2. Specifications Characteristics Contact Rating Item Arrangement Initial contact resistance, max 2 Form C, 3 Form C Contact material 4 Form C Nominal switching capacity Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Between open contacts Breakdown voltage (Initial) Electrical characteristics Between contact sets Between contact and coil Temperature rise Operate time*2 Release time*2 Functional Destructive Functional Vibration resistance Destructive Mechanical Shock resistance Mechanical characteristics Expected life Conditions Conditions for operation, transport and storage*3 Max. Operating speed Unit weight Specifications 2 Form C, 3 Form C, 4 Form C Max. 15 m (By voltage drop 6 V DC 1A) Ag Ag alloy (cd free) 10A 250V AC (resistive load) 100mA 5V DC Min. 100M (at 500V DC) Measurement at same location as "Initial breakdown voltage" section. 1,000 Vrms for 1min (2 Form C, 4 Form C). 2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.) 1,500 Vrms for 1min (2 Form C, 4 Form C). 2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.) 1,500 Vrms for 1min (2 Form C, 4 Form C). 2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.) Max. 65C (By temperature method, at 40C, nominal current) Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C) (Nominal voltage applied to the coil, excluding contact bounce time.) Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C) (Nominal voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.) 10 to 55 Hz at double amplitude of 2 mm Min. 107 Ambient temperature: -50C to +40C -58F to +104F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 cpm (at max. rating) 2 Form C: approx. 60g 2.12oz, 3 Form C: approx. 100g 3.53oz, 4 Form C: approx. 125g 4.41oz Notes: *1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *2 For the AC coil types, the operate/release time will differ depending on the phase. *3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT. 3. Electrical life 1) AC load Voltage Load Current 125V AC Resistive (A) (cos=1) Inductive (A) (cos=0.4) -- -- 10 7.5 5 3 1 0.7 250V AC Resistive (A) (cos=1) Inductive (A) (cos=0.4) 10 7.5 7.5 5 3 2 0.6 0.4 Expected life Min. 2x105 Min. 5x105 Min. 106 Min. 2x106 Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable. 2) DC load Voltage Load Current 24V DC Resistive (A) -- 7.5 5 1 125V DC Inductive (A) 7 5 3 0.6 Resistive (A) -- 0.5 0.3 0.1 Inductive (A) -- 0.4 0.2 0.06 Expected life Min. 2x105 Min. 5x105 Min. 106 Min. 2x106 Note: For DC inductive loads, use an arc suppressing circuit. Note: Cautions at DC load use When used under a DC load operating at high repetition rate with considerable arcing, corrosion of the contacts and/or the contact blades is likely to occur. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Including discontinued products ( HP ) 4. Life of LED and neon lamp (with operation indication) Continuous 25,000 hours (approx. 3 years) 50,000 hours (approx. 5.5 years) With neon lamp With LED indication With neon lamp Use rating (ON time) 50% Approx. 6 years 100,000 hours (approx. 11 years) Schematic Neon lamp (Coil terminal No.) Schematic With LED indication LED Coil terminal No. and polarity (DC type) LED Polarity HP2 HP3 HP4 (+) (-) 7 2 10 2 10 1 Terminal No. Protection diode (Coil terminal No.) REFERENCE DATA 1. Life curve Mechanical life more than 10,000,000 operations 900 AC resistive load Contact current, A Operations, x104 1,000 2. Max. switching capacity 800 700 600 500 10 AC inductive load (cos=0.4) 300 200 0 25 100 0 125 V A VA C cos C cos DC resistive load 1 DC inductive load (L/R=7ms) 400 =1 =1 5 0.1 10 10 100 Load current, A 500 1,000 Contact voltage, V DIMENSIONS (Unit: mm inch) Plug-in type (2 Form C) External dimensions Schematic (Bottom view) 5 8 5 .197.315 .197 0.5 .020 8 1 7 2 6 44 1.732 51 2.008 5 7 .276 0.8 .031 25 .984 15 .591 Compatible with tab terminal #205 series receptacle. 0.8 .031 8 1 7 6 2 3 5 4 5.26 5.26 .207 .207 10 .394 5.26 .207 5.26 .207 0.8 .031 0.8 .031 3 9.5 .374 7.5 36 .2951.417 5.8 .228 5.3 .209 Dimension: Max. 2mm .079 inch: 2 to 9mm .079 to .354 inch: 9 to 20mm .354 to .787 inch: Min. 20mm .787 inch: Tolerance 0.2 .008 0.5 .020 1 .039 1.5 .059 All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. 4 Including discontinued products ( ) HP Plug-in type (3 Form C) External dimensions Schematic (Bottom view) 5 8 5 .197 .315 .197 38 1.496 2 10 0.5 .020 44 1.732 5 .197 11 3 1 9 6 4 8 7 5 7 .276 36 1.417 3 .118 Compatible with tab terminal #187 series receptacle. 38 1.496 11 11 .433 .433 4.75 4.75 4.75 .187 .187 .187 2.5 2.5 .098 .098 Plug-in type (4 Form C) 0.5 .020 5.75 .226 5.5 .217 0.5 .020 8.5 0.5 .020 .335 36 7.65 1.417 2 .079 .301 0.5 .020 4.1 2 .079 .161 Dimension: Max. 2mm .079 inch: 2 to 9mm .079 to .354 inch: 9 to 20mm .354 to .787 inch: Min. 20mm .787 inch: External dimensions Tolerance 0.2 .008 0.5 .020 1 .039 1.5 .059 Schematic (Bottom view) 9 15 11 2 0.5 .020 10 44 1.732 51 2.008 1 8 14 7 6 7 .276 0.8 .031 50 1.969 40 1.575 10 .394 0.8 0.8 .031 .031 Compatible with tab terminal #205 series receptacle. 0.8 .031 2 9 15 11 10 1 8 14 12 3 7 9 5 4 5.26 5.26 .207 .207 10 .394 5.26 5.26 .207 .207 25 .984 10 .394 5.26 .207 5.26 .207 0.8 .031 0.8 .031 9.5 .374 36 7.5 1.417 .295 5.8 .228 5.3 .209 Dimension: Max. 2mm .079 inch: 2 to 9mm .079 to .354 inch: 9 to 20mm .354 to .787 inch: Min. 20mm .787 inch: All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Tolerance 0.2 .008 0.5 .020 1 .039 1.5 .059 12 3 5 4 Including discontinued products ( HP TM type (2 Form C) External dimensions Mounting hole diagram 2.8 .110 Relay space (Area shown by the broken line) 45.5 1.791 46.8 1.843 7 .276 2-M4 screw hole or 2-4.5 dia. hole 2-M.157 screw hole or 2-.177 dia. hole 5.5 .217 24.7 .972 2 .079 30 1.181 35.7 1.406 0.8 .031 Dimension: Max. 2mm .079 inch: 2 to 9mm .079 to .354 inch: 9 to 20mm .354 to .787 inch: Min. 20mm .787 inch: 15 .591 5.26 .207 5.26 .207 0.8 .031 0.8 .031 Tolerance 0.2 .008 0.5 .020 1 .039 1.5 .059 (Pitch for side-by-side mounting) 9.5 .374 45.5 7.5 1.791 58 2.283 .295 5.8 .228 Installed relay 35.7 1.406 5.3 .209 2.25R .089R 5.26 .207 4.5 .177 Tolerance: 0.1 .004 Compatible with tab terminal #205 series receptacle. 0.8 .031 5.26 .207 10 .394 52.3 2.059 2-M4 screw 2-M.157 Schematic (Bottom view) Direct mounting type (3 Form C) 8 7 1 2 6 5 3 4 Spring washer Nut External dimensions Panel (chassis) Mounting hole diagram 38 1.496 16 .630 4.2 .165 Relay space (Area shown by the broken line) 2.1R .083R 44 1.732 60 2.362 73.5 7 2.894 .276 11 .433 3 .118 5 .197 Tolerance 0.2 .008 0.5 .020 1 .039 1.5 .059 2.5 .098 60 2.362 2-M4 screw hole (or 2-4.2 dia. hole) 2-M.157 screw hole (or 2-.165 dia. hole) 2 .079 20.5 .807 2.1R .083R Dimension: Max. 2mm .079 inch: 2 to 9mm .079 to .354 inch: 9 to 20mm .354 to .787 inch: Min. 20mm .787 inch: ) 40 1.575 4.2 36 .165 1.417 16 .630 38 Compatible with tab terminal 1.496 #187 series receptacle. 11 11 .433 .433 4.75 4.75 4.75 .187 .187 .187 2.5 5.75 .098 .226 0.5 .020 5.5 0.5 .217 .020 8.5 0.5 .020 .335 36 7.65 1.417 2 .079 .301 0.5 4.1 .020 .161 2 .079 Tolerance: 0.1 .004 (Pitch for side-by-side mounting) Installed relay 2-M4 screw 2-M.157 Panel (chassis) Nut Schematic (Bottom view) 5 .197 60 2.362 44 73.5 1.732 2.894 11 .433 2 10 11 3 1 9 6 4 8 7 5 Spring washer 20.5 .807 16 .630 38 1.496 7 .276 All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. 36 1.417 Including discontinued products ( ) VDE HP RELAY ACCESSORIES Partial approval ACCESSORIES (Sockets and Terminal sockets) Socket for rectangular hold boring HP RELAY Terminal socket for DIN rail assembly Compliance with RoHS Directive TYPES 1. For DIN rail terminal sockets, hold-down clip included. 2. For square hole sockets, powerful hold-down clip included. Type Square hole socket DIN rail terminal socket Common part No. of poles Item Part No. 2-pole 3-pole 4-pole 2-pole 3-pole 4-pole 2/3/4-pole (common) HP2-square hole socket HP3-square hole socket HP4-square hole socket HP2-DIN terminal socket HP3-DIN terminal socket HP4-DIN terminal socket HP-hold down clip for socket HP2-SRS HP3-SRS HP4-SRS HP2-SFD HP3-SFD HP4-SFD AW5806 Note: Socket and terminal socket conform to UL, CSA as standard. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Packing quantity Carton 20 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 5 pcs. -- Case 100 pcs. 50 pcs. 50 pcs. 50 pcs. 50 pcs. 25 pcs. 50 pcs. Including discontinued products ( HP RELAY ACCESSORIES DIMENSIONS (Unit: mm inch) 1. Socket for rectangular hold boring (hold-down clip included) HP2-Socket (HP2-SRS) Front surface mounting Mounting dimensions 2-4.2 dia. hole (or 2-M4 screw hole) 2-.165 dia. hole (or 2-M.157 screw hole) 480.5 1.890.020 Hold-down clip HP relay 523 2.047.118 Socket M4 screw M.157 Spring washer 34 1.339 24 .945 When the socket is mounted from the top of the panel (chassis). ) 14 .551 Panel (chassis) Tolerance: 0.1 .004 External dimensions Hold-down clip HP relay Rear surface mounting 533 2.087.118 5 .197 480.2 1.890.008 38 56 1.496 2.205 22 .866 39 1.535 33 1.299 4.2 .165 5 .197 6.2 .244 4.1 .161 31 1.220 When the socket is mounted from below the panel (chassis). 1.0 .039 6 .236 13 .512 5.5 .217 30 1.181 Socket M4 screw M.157 Spring washer 52 2.047 Tolerance: 0.1 .004 13 .512 Panel (chassis) Notes: 1. Optimum space-saving panel cut-out. 2. Can be mounted from either the front or the rear of the panel. 3. Hold-down clip is included in package. General tolerance: 0.1 .004 HP3-Socket (HP3-SRS) Front surface mounting Mounting dimensions 2-4.20.1 dia. hole (or M4 screw hole) 2-.165.004 dia. hole (or M.157 screw hole) 31+1 -0 1.220+.039 -0 480.5 1.890.020 Hold-down clip HP relay 523 2.047.118 Socket M4 screw M.157 Spring washer 15.5 .610 31+1 -0 1.220+.039 -0 Panel (chassis) Tolerance: 0.1 .004 External dimensions Rear surface mounting Hold-down clip HP relay 480.2 5 1.890.079 .197 56 22 38 .866 2.205 1.496 5 .197 3.5 .138 4.1 .161 45 1.772 3.5 .138 6.2 .244 1.0 .039 14.5 5.5 .571 .217 533 2.087.118 52 2.047 30 1.181 8 .315 39 1.535 4.2 .165 46+1 -0 +.039 1.811-0 Tolerance: 0.1 .004 General tolerance: 0.1 .004 Socket M4 screw M.157 Spring washer (48) (1.890) +1 -0 +.039 -0 14.5 .571 Panel (chassis) Notes: 1. Optimum space-saving panel cut-out. 2. Can be mounted from either the front or the rear of the panel. 3. Hold-down clip is included in package. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. Including discontinued products ( ) HP RELAY ACCESSORIES HP4-Socket (HP4-SRS) Front surface mounting Mounting dimensions 2-M4 screw hole (or 4.20.1 dia. hole) 2-M.157 screw hole (or .165.004 dia. hole) Hold-down clip HP relay 523 2.047.118 34 +1 -0 1.339 +.039 -0 48 +1 -0 +.039 1.890 -0 Socket M4 screw M.157 Spring washer 14 .551 480.5 1.890.020 Panel (chassis) Tolerance: 0.1 .004 External dimensions Rear surface mounting Hold-down clip HP relay 2-4.2 dia. hole 2-.165 dia. 5 .197 480.2 1.890.008 38 56 1.496 2.205 22 .866 33 1.299 6.2 .244 1.0 .039 58 2.283 13 5.5 .512 .217 Socket M4 screw M.157 Spring washer 39 +1 -0 1.535 +.039 -0 480.2 1.890.008 3 .118 5 .197 4.1 .161 533 2.087.118 3 .118 6 .236 A 3 .118 General tolerance: 0.1 .004 3 25 .118 .984 58 +1 -0 2.283 +.039 -0 Tolerance: 0.1 .004 13 .512 Panel (chassis) Notes: 1. Optimum space-saving panel cut-out. 2. Can be mounted from either the front or the rear of the panel. 3. Hold-down clip is included in package. * When using the former hold-down clip, it is necessary to cut out the A section marked by the broken line (not necessary with the powerful hold-down clip). 2. Terminal socket for DIN rail assembly (hold-down clip and installation screw included) HP2-Terminal socket for DIN rail assembly (HP2-SFD) External dimensions 23.80.6 .937.024 100.6 .394.024 * Installation screw block (installation screw, hexagonal nut, spring washer) Hold-down clip Schematic M3.5 screw M.138 220.6 .866.024 150.2 .591.008 4.10.3 4.1.012 60.3 6.012 2 7 1 8 3 6 Mounting hole diagram 220.2 120.2 220.2 .866.008 .472.008 .866.008 80 3.150 690.5 2.717.020 691 2.717.039 0.60.15 .024.006 9.50.2 581 2.283.039 .374.008 7.50.2 361 .295.008 1.417.039 801 3.150.039 4 5 4 30 1.181 .157 5.80.2 .228.008 33.80.6 1.331.024 37.90.6 1.492.024 HP2 relay 80.2 .315.008 300.6 1.181.024 Notes: 1. For direct mounting, use the included installation screw block. 2. A hold-down clip is included with the terminal socket. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. 2-M4 screw hole (or 4.20.1 dia. hole) 2-M.157 screw hole (or .165.004 dia. hole) Panel hole dimensions for side-by-side installation 30 1.181 Including discontinued products ( HP RELAY ACCESSORIES ) HP3-Terminal socket for DIN rail assembly (HP3-SFD) External dimensions 23.80.6 .937.024 100.6 .394.024 Schematic * Installation screw block (installation screw, hexagonal nut, spring washer) 2 M3.5 screw M.138 370.6 1.457.024 4.10.3 .161.012 60.3 .236.012 Hold-down clip 691 1.750.15 2.717.039 .069.006 7.650.2 581 2.283.039 .301.008 8.50.2 361 .335.008 1.417.039 801 3.150.039 10 1 3 370.2 120.2 370.2 1.457.008 12.008 1.457.008 11 4 5 6 80 3.150 690.5 2.717.020 9 7 8 4 45 1.772 .157 5.50.2 .217.008 33.80.6 1.331.024 37.90.6 1.492.024 Mounting hole diagram 80.2 .315.008 450.6 1.772.024 HP3 relay 2-M4 screw hole (or 4.20.1 dia. hole) 2-M.157 screw hole (or .165.004 dia. hole) Panel hole dimensions for side-by-side installation 45 1.772 Notes: 1. For direct mounting, use the included installation screw block. 2. A hold-down clip is included with the terminal socket. HP4-Terminal socket for DIN rail assembly (HP4-SFD) External dimensions 23.80.6 .937.024 100.6 .394.024 Schematic * Installation screw block (installation screw, hexagonal nut, spring washer) Hold-down clip 4.10.3 .161.012 60.3 .236.012 2 4 16 11 3 691 0.60.15 2.717.039 .024.006 9.50.2 581 2.283.039 .374.008 7.50.2 361 1.417.039 .295.008 801 3.150.039 1 M3.5 screw M.138 530.6 2.087.024 150.2 150.2 .591.008 .591.008 80.2 .315.008 5 17 10 15 9 12 14 8 6 Mounting hole diagram 120.2 530.2 530.2 .472.008 2.087.008 2.087.008 80 3.150 690.5 2.717.020 7 61 2.402 4 .157 61 2.402 5.80.2 .228.008 33.80.6 1.331.024 37.90.6 1.492.024 HP4 relay 100.2 .394.008 100.2 250.1 .394.008 .984.004 610.6 2.402.024 Panel hole dimensions for side-by-side installation Notes: 1. For direct mounting, use the included installation screw block. 2. A hold-down clip is included with the terminal socket. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd. 2-M4 screw hole (or 4.20.1 dia. hole) 2-M.157 screw hole (or .165.004 dia. hole) Including discontinued products ( ) HP RELAY ACCESSORIES NOTES 1. There are two types of HP relay: plugin and direct mounting (HP2-TM and HP3-M only). Avoid use of direct mounting types in sockets or terminal sockets. Note: Mounting measurements for direct mounting types (HP2-TM and HP3-M) are shown in the drawing on page 146. 2. The terminals are compatible with tab terminals. Consequently, for direct mounting types, in addition to soldering, AMP terminals can be used. Part number HP2 HP3 HP4 Compatible tab terminal #205 series #187 series #205 series 3. When tightening the fixing screws of direct mounting types, use washers to prevent damage or distortion. The optimum torque range is 0.49 to 0.69 N*m, (5 to 7 kgf*cm). To prevent loosening of direct mounting types, terminal sockets and sockets, etc., when fixing the screws, use spring washers, etc. Moreover, wiring (soldering), should be done with care while ensuring strong connections. 4. When tightening terminal socket fixing screws, to prevent damage, the optimum torque range should be 0.784 to 0.98 N*m, (8 to 10 kgf*cm). 5. Avoid use in adverse conditions, such as where the relay will be subjected to strong vibrations or shock, where there is exposure to harmful gas, or where ambient temperatures are high (more than 40C). 6. Use in DC load Abnormal wear of the contacts and contact springs will occur when the switching frequency is high and there are large arcs. In particular, if high-frequency operation in hot or humid conditions is intended, use arc-suppressing circuits. 7. There is no particular specification for HP relay mounting orientation. 8. Do not insert or remove relays into or out of live circuits. For Cautions for Use, see Relay Technical Information. All Rights Reserved (c) COPYRIGHT Panasonic Electric Works Co., Ltd.